0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FP2-EM6

FP2-EM6

  • 厂商:

    NAIS(松下)

  • 封装:

  • 描述:

    ROM SKT EXPANSION RAM

  • 数据手册
  • 价格&库存
FP2-EM6 数据手册
              Product types CPU units (Built-in RAM) FP2 FPSH Intelligent units for remote I/O control Optional memory Other Operation Product number Product name Built-in RAM speed Expansion RAM ROM IC memory card Clock/calendar Comment memory Standard type CPU unit FP2-C1 note 1) note 2) note 3) From Available Available CPU unit 64-point input Not available FP2-C1D 16 k steps Available Available 0.35 µs (See below.) (See below.) CPU unit with S-LINK FP2-C1SL Standard type CPU unit FP2-C2 60 k steps Not available Available (See below.) Not available Available (Built-in) Available (Built-in) From CPU unit with IC memory card interface 60 k steps Not available Available (Built-in) Available (See below.) Available (Built-in) Available (Built-in) FP2-C2P 0.03 µs CPU unit with IC memory card interface 120 k steps Not available Available (Built-in) Available (See below.) Available (Built-in) Available (Built-in) FP2-C3P Part number AFP2211 AFP2212 AFP2214 AFP2231 AFP2235 AFP2255 Notes: 1) For FP2 CPU unit, the capacity can be expanded up to 32 k steps using the expansion RAM of the optional memory. 2) The expansion memory unit (optional memory) with clock/calendar function is required for FP2 CPU unit. 3) The expansion memory unit (optional memory) with comment input function is required for FP2 CPU unit. Expansion memory unit For FP2 F-ROM EP-ROM Function Comment input Clock/calendar Expansion RAM ROM socket Available Available Not available Not available Available Available Available Not available Available Available Available Available Not available Not available Available Available Not available Not available Not available Available FLASH-ROM for program copy and ROM operation. Equivalent to SST-29EE010-120-4C-PH Enables writing with the programming tool when attached to the CPU unit. EP-ROM for program storage and ROM operation. Equivalent to M27C1001-12F1 A commercially available ROM writer is required. Product number Part number FP2-EM1 FP2-EM2 FP2-EM3 FP2-EM6 FP2-EM7 AFP2201 AFP2202 AFP2203 AFP2206 AFP2207 FP2-EM4 AFP2204 FP2-EM5 AFP2205 Optional memories for FP2SH ROM for FP2SH AFP2231 Part number Specification F-ROM EP-ROM Socket for ftting ROM to the CPU unit FLASH-ROM for program copy and ROM operation. Equivalent to SST-29EE020-150-4C-PH Enables writing with the programming tool when attached to the CPU unit. EP-ROM for program storage and ROM operation. Equivalent to M27C2001-150F1. A commercially available ROM writer is required. AFP2207 Backup unnecessary. Perfect for program memory Used for readout when using data memory. AIC50020 Perfect for data memory Can also be used for program backup. Battery backups. AIC52000 IC memory card (Small PC F-ROM card) for FP2SH CPU unit with SRAM IC memory card interface FP2 CPU unit with S-LINK FP2 S-LINK unit AFP5208 FP2-AD8VI FP2 Analog FP2-AD8X input unit FP2-RTD FP2 Analog output unit Specification Conventional type FP2 Backplane H type FP2 Expansion cable Product number FP2-BP05 FP2-BP07 FP2-BP09 FP2-BP12 FP2-BP14 FP2-BP11MH FP2-BP10EH FP2-EC FP2-EC2 Part number AFP25005 AFP25007 AFP25009 AFP25012 AFP25014 AFP25011MH AFP25010EH AFP2510 AFP2512 Power supply unit Product name FP2 Power supply unit Specification Product number Input: 100 to 120 V AC, Output: 2.5 A Input: 200 to 240 V AC, Output: 2.5 A Input: 100 to 240 V AC, Output: 5 A Input: 24 V AC, Output: 5 A FP2-PSA1 FP2-PSA2 FP2-PSA3 FP2-PSD2 Part number AFP2631 AFP2632 AFP2633 AFP2634 I/O units Product name FP2 Input unit FP2 Output unit FP2 I/O mixed unit Number of point 16 points 32 points DC input 64 points 6 points Relayoutput 16 points 16 points Transistor output 32 points NPN 64 points 16 points Transistor output 32 points PNP 64 points DC input, Transistor Input 32 points Output 32 points output NPN DC input, Transistor Input 32 points Output 32 points output PNP Type Connection method Terminal Connector Connector Terminal Terminal Terminal Connector Connector Terminal Connector Connector Specification 12-24V DC 24V DC 24V DC 5 A, 2 points per one common 2 A, 8 points per one common 0.5A (12-24V DC), 0.1A (5V DC) 0.1A (12-24V DC), 50mA (5V DC) 0.1A (12-24V DC), 50mA (5V DC) 0.5A (12-24V DC), 0.1A (5V DC) 0.1A (12-24V DC), 50mA (5V DC) 0.1A (12-24V DC), 50mA (5V DC) Input 24 V DC Output 0.1 A (12 to 24 V DC), 50 mA (5 V DC) Connector Input 24 V DC Output 0.1 A (12 to 24 V DC), 50 mA (5 V DC) with on pulse catch input Input 24 V DC Output 0.1 A (12 to 24 V DC), 50 mA (5 V DC) Connector Input 24 V DC Output 0.1 A (12 to 24 V DC), 50 mA (5 V DC) with on pulse catch input Product number Part number FP2-X16D2 FP2-X32D2 FP2-X64D2 FP2-Y6R FP2-Y16R FP2-Y16T FP2-Y32T FP2-Y64T FP2-Y16P FP2-Y32P FP2-Y64P FP2-XY64D2T FP2-XY64D7T FP2-XY64D2P FP2-XY64D7P AFP23023 AFP23064 AFP23067 AFP23101 AFP23103 AFP23403 AFP23404 AFP23407 AFP23503 AFP23504 AFP23507 AFP23467 AFP23477 AFP23567 AFP23577 Note: Pressure welding socket is supplied. A special tool (Part number AXY52000) is needed for connection. Please purchase separately if you are using a terminal or flat cable socket. Maintenance parts Product name Battery Dummy unit 18 Specification For FP2, button type battery, CR2450 or equivalent For FP2SH CPU unit, battery with cable For blank slot Max. 2048 points per one unit FP2-MW AFP2720 256 points at S-LINK section FP2-C1SL AFP2214 128 points per one unit FP2-SL2 AFP2780 Number of I/O points Product number Part number Analog input: 8 channels Analog input: 8 channels R.T.D. input: 8ch Analog input: 4 channels FP2-AD8VI FP2-AD8X FP2-RTD FP2-DA4 AFP2400L AFP2401 AFP2402 AFP2410 Product number Part number Positioning unit, High-speed counter unit and Pulse I/O unit Product name FP2 Positioning unit Multiifunction type note 3) Part number AFC8801 AFP8801 AFP2300 Specification Number of axes controlled Output type Control Configurator PM Transistor Line drive Speed command FP2-PN2AN FP2-PN4AN FP2-PN8AN − 2 axes 4 axes 8 axes Tool software for positioning unit RTEX (English) 2 axes, independent 1 pps to 500 kpps 4 axes, independent 2 axes, independent 1 pps to 4 Mpps 4 axes, independent FP2-PP21 FP2-PP41 FP2-PP22 FP2-PP42 AFP243610 AFP243620 AFP243630 AFPS66510 AFP2432 AFP2433 AFP2434 AFP2435 8 interrupt inputs 4-channel high-speed counter 8 comparison outputs Input: 24 V DC Output: 5 to 24 V DC (0.1 A, 12 points/0.8 A, 4 points) NPN output FP2-HSCT AFP2441 FP2 High-speed counter unit PNP output FP2-HSCP AFP2451 NPN output FP2-PXYT AFP2442 FP2 Pulse I/O unit 8 interrupt inputs 4-channel high-speed counter 8 comparison outputs 4 pulse output channels 4 PWM output channels Input: 24 V DC Output: 5 to 24 V DC (0.1 A, 12 points/0.8 A, 4 points) PNP output FP2-PXYP AFP2452 Backplane 5-module type (for basic) 7-module type (for basic and expansion) 9-module type (for basic and expansion) 12-module type (for basic and expansion) 14-module type (for basic and expansion) 8 slots (for basic ) 8 slots (for expansion) 0.6 m 2m Part number Not insulated Voltage: 1 to 5 V, -10 to +10 V Current: 4 to 20 mA, -20 to +20 mA Insulated Voltages, currents, thermocouples, resistance thermometer devices R.T.D. type: Pt 100, JPt 100, JPt 1000 type Voltage range: -10 to +10 V Current range: 0 to 20 mA Resolution: 1/4096 AFP5209 Note: Please refer to “FPΣ Product Types” for FP Memory Loader. Product name Product number Specification Product name FP2 Positioning unit RTEX Product name Expansion memory unit FP2 Multi-wire link unit Controllable I/O points Specification Can connect as the remote I/O system MEWNET-F master station. Perfect for remote I/O systems using many points Direct connection to SUNX Co., Ltd., S-LINK reduced-wiring system CPU unit with 128 points x 2 channels Direct connection to SUNX Co., Ltd., S-LINK reduced-wiring system CPU unit with 128 points x 2 channels Intelligent units for analog I/O Optional memories for FP2 Product name Product name Notes: 1) Pressure welding socket is supplied. A special tool (part no. AXY52000) is needed for connection. Please purchase separately if you are using a terminal or flat cable socket. 2) Please refer to “FPΣ Product Types” for Motor driver I/F terminal II. 3) Previous FP2 positioning units AFP2430 (FP2-PP2) and AFP2431 (FP2-PP4) are not compatible with the multi-function type FP2 positioning unit. Please contact us. Serial communication and Link-related intelligent units Product name Specification Number of channels Product number Part number 1ch FP2-VE AFP27960 1ch FP2-ET1 AFP2790 − − 1ch FP2-MW AFP2720 2ch FP2-MCU AFP2465 1ch 1ch 1ch FP2-CB232 FP2-CB422 FP2-CB485 AFP2803 AFP2804 AFP2805 2ch FP2-CCU AFP2462 2ch FP2-SDU AFP2460 10 Mbps, 8,192 points/8,192 words, 99 units max. (VE mode), 254 units max. (FL-net), 2,500 m * For FP2SH (Cannot be used for FP2) Ethernet-compatible unit for FP2/FP2SH FP2 ET-LAN unit To be mounted on the CPU backplane Control Configurator ET ET-LAN unit setting software (English) For PLC links FP2 Multi-wire link unit Compatible with MEWNET-W/MEWNET-W2 Up to two blocks to be attached can be selected among RS485, RS232C, and RS422 blocks. FP2 Multi-communication unit General-purpose serial communications, computer links, PLC links (MEWTNET-W0) (For the multi-communication unit) 230 kbps, 15 m max. RS232C block (For the multi-communication unit) 230 kbps, 1,200 m max. RS422 block RS485 block (For the multi-communication unit) For PLC links (MEWNET-W0): 115 kbps, 16 stations, 1,200 m FP2 Computer For 1:1 communication between a PLC and a computer communication unit RS232C x 2 ch Connection with a control panel is also possible. For communications with general-purpose RS232C devices FP2 Serial data unit The serial input/output is executed by sequence commands. FP2 MEWNET VE-link unit AAFPS32510 Control FPWIN GR for Windows Product name FPWIN GR for Windows Type English: Full type English: Small type English: Ver. up type Chinese Chinese: Ver. up type Korean CD-ROM for Windows CD-ROM for Windows CD-ROM for Windows CD-ROM for Windows CD-ROM for Windows CD-ROM for Windows Part number AFPS10520 AFPS11520 AFPS10520R AFPS10820 AFPS10820R AFPS10920 FP-X FPΣ A A A A FP0 FP-e A A A A A • Applicable PLC FP0 FP1*1 FP2 10k A A A A A N/A A A A FP2SH FP-M*1 FP3*1 FP10SH • A N/A A A A N/A A A A A: Available, N/A: Not available *1 FP1, FP-M, and FP3/FP10SH have been discontinued. Control FPWIN Pro (IEC61131-3 compliant Windows version software) Product name FPWIN Pro for Windows Type English: Full type English: Small type *1: Ver. 5.1 or later will be supported soon. *2: FP1, FP-M, and FP3/FP10SH have been discontinued. CD-ROM for Windows CD-ROM for Windows Part number FP-X FPΣ AFPS50550 AFPS51550 A A A A FP0 FP-e A A • Applicable PLC FP0 FP1*1 FP2 10k A A A A A N/A FP2SH A N/A FP3*1 FP-M*1 FP10SH • A A A N/A A: Available, N/A: Not available 19 Product types CPU units (Built-in RAM) FP2 FPSH Intelligent units for remote I/O control Optional memory Other Operation Product number Product name Built-in RAM speed Expansion RAM ROM IC memory card Clock/calendar Comment memory Standard type CPU unit FP2-C1 note 1) note 2) note 3) From Available Available CPU unit 64-point input Not available FP2-C1D 16 k steps Available Available 0.35 µs (See below.) (See below.) CPU unit with S-LINK FP2-C1SL Standard type CPU unit FP2-C2 60 k steps Not available Available (See below.) Not available Available (Built-in) Available (Built-in) From CPU unit with IC memory card interface 60 k steps Not available Available (Built-in) Available (See below.) Available (Built-in) Available (Built-in) FP2-C2P 0.03 µs CPU unit with IC memory card interface 120 k steps Not available Available (Built-in) Available (See below.) Available (Built-in) Available (Built-in) FP2-C3P Part number AFP2211 AFP2212 AFP2214 AFP2231 AFP2235 AFP2255 Notes: 1) For FP2 CPU unit, the capacity can be expanded up to 32 k steps using the expansion RAM of the optional memory. 2) The expansion memory unit (optional memory) with clock/calendar function is required for FP2 CPU unit. 3) The expansion memory unit (optional memory) with comment input function is required for FP2 CPU unit. Expansion memory unit For FP2 F-ROM EP-ROM Function Comment input Clock/calendar Expansion RAM ROM socket Available Available Not available Not available Available Available Available Not available Available Available Available Available Not available Not available Available Available Not available Not available Not available Available FLASH-ROM for program copy and ROM operation. Equivalent to SST-29EE010-120-4C-PH Enables writing with the programming tool when attached to the CPU unit. EP-ROM for program storage and ROM operation. Equivalent to M27C1001-12F1 A commercially available ROM writer is required. Product number Part number FP2-EM1 FP2-EM2 FP2-EM3 FP2-EM6 FP2-EM7 AFP2201 AFP2202 AFP2203 AFP2206 AFP2207 FP2-EM4 AFP2204 FP2-EM5 AFP2205 Optional memories for FP2SH ROM for FP2SH AFP2231 Part number Specification F-ROM EP-ROM Socket for ftting ROM to the CPU unit FLASH-ROM for program copy and ROM operation. Equivalent to SST-29EE020-150-4C-PH Enables writing with the programming tool when attached to the CPU unit. EP-ROM for program storage and ROM operation. Equivalent to M27C2001-150F1. A commercially available ROM writer is required. AFP2207 Backup unnecessary. Perfect for program memory Used for readout when using data memory. AIC50020 Perfect for data memory Can also be used for program backup. Battery backups. AIC52000 IC memory card (Small PC F-ROM card) for FP2SH CPU unit with SRAM IC memory card interface FP2 CPU unit with S-LINK FP2 S-LINK unit AFP5208 FP2-AD8VI FP2 Analog FP2-AD8X input unit FP2-RTD FP2 Analog output unit Specification Conventional type FP2 Backplane H type FP2 Expansion cable Product number FP2-BP05 FP2-BP07 FP2-BP09 FP2-BP12 FP2-BP14 FP2-BP11MH FP2-BP10EH FP2-EC FP2-EC2 Part number AFP25005 AFP25007 AFP25009 AFP25012 AFP25014 AFP25011MH AFP25010EH AFP2510 AFP2512 Power supply unit Product name FP2 Power supply unit Specification Product number Input: 100 to 120 V AC, Output: 2.5 A Input: 200 to 240 V AC, Output: 2.5 A Input: 100 to 240 V AC, Output: 5 A Input: 24 V AC, Output: 5 A FP2-PSA1 FP2-PSA2 FP2-PSA3 FP2-PSD2 Part number AFP2631 AFP2632 AFP2633 AFP2634 I/O units Product name FP2 Input unit FP2 Output unit FP2 I/O mixed unit Number of point 16 points 32 points DC input 64 points 6 points Relayoutput 16 points 16 points Transistor output 32 points NPN 64 points 16 points Transistor output 32 points PNP 64 points DC input, Transistor Input 32 points Output 32 points output NPN DC input, Transistor Input 32 points Output 32 points output PNP Type Connection method Terminal Connector Connector Terminal Terminal Terminal Connector Connector Terminal Connector Connector Specification 12-24V DC 24V DC 24V DC 5 A, 2 points per one common 2 A, 8 points per one common 0.5A (12-24V DC), 0.1A (5V DC) 0.1A (12-24V DC), 50mA (5V DC) 0.1A (12-24V DC), 50mA (5V DC) 0.5A (12-24V DC), 0.1A (5V DC) 0.1A (12-24V DC), 50mA (5V DC) 0.1A (12-24V DC), 50mA (5V DC) Input 24 V DC Output 0.1 A (12 to 24 V DC), 50 mA (5 V DC) Connector Input 24 V DC Output 0.1 A (12 to 24 V DC), 50 mA (5 V DC) with on pulse catch input Input 24 V DC Output 0.1 A (12 to 24 V DC), 50 mA (5 V DC) Connector Input 24 V DC Output 0.1 A (12 to 24 V DC), 50 mA (5 V DC) with on pulse catch input Product number Part number FP2-X16D2 FP2-X32D2 FP2-X64D2 FP2-Y6R FP2-Y16R FP2-Y16T FP2-Y32T FP2-Y64T FP2-Y16P FP2-Y32P FP2-Y64P FP2-XY64D2T FP2-XY64D7T FP2-XY64D2P FP2-XY64D7P AFP23023 AFP23064 AFP23067 AFP23101 AFP23103 AFP23403 AFP23404 AFP23407 AFP23503 AFP23504 AFP23507 AFP23467 AFP23477 AFP23567 AFP23577 Note: Pressure welding socket is supplied. A special tool (Part number AXY52000) is needed for connection. Please purchase separately if you are using a terminal or flat cable socket. Maintenance parts Product name Battery Dummy unit 18 Specification For FP2, button type battery, CR2450 or equivalent For FP2SH CPU unit, battery with cable For blank slot Max. 2048 points per one unit FP2-MW AFP2720 256 points at S-LINK section FP2-C1SL AFP2214 128 points per one unit FP2-SL2 AFP2780 Number of I/O points Product number Part number Analog input: 8 channels Analog input: 8 channels R.T.D. input: 8ch Analog input: 4 channels FP2-AD8VI FP2-AD8X FP2-RTD FP2-DA4 AFP2400L AFP2401 AFP2402 AFP2410 Product number Part number Positioning unit, High-speed counter unit and Pulse I/O unit Product name FP2 Positioning unit Multiifunction type note 3) Part number AFC8801 AFP8801 AFP2300 Specification Number of axes controlled Output type Control Configurator PM Transistor Line drive Speed command FP2-PN2AN FP2-PN4AN FP2-PN8AN − 2 axes 4 axes 8 axes Tool software for positioning unit RTEX (English) 2 axes, independent 1 pps to 500 kpps 4 axes, independent 2 axes, independent 1 pps to 4 Mpps 4 axes, independent FP2-PP21 FP2-PP41 FP2-PP22 FP2-PP42 AFP243610 AFP243620 AFP243630 AFPS66510 AFP2432 AFP2433 AFP2434 AFP2435 8 interrupt inputs 4-channel high-speed counter 8 comparison outputs Input: 24 V DC Output: 5 to 24 V DC (0.1 A, 12 points/0.8 A, 4 points) NPN output FP2-HSCT AFP2441 FP2 High-speed counter unit PNP output FP2-HSCP AFP2451 NPN output FP2-PXYT AFP2442 FP2 Pulse I/O unit 8 interrupt inputs 4-channel high-speed counter 8 comparison outputs 4 pulse output channels 4 PWM output channels Input: 24 V DC Output: 5 to 24 V DC (0.1 A, 12 points/0.8 A, 4 points) PNP output FP2-PXYP AFP2452 Backplane 5-module type (for basic) 7-module type (for basic and expansion) 9-module type (for basic and expansion) 12-module type (for basic and expansion) 14-module type (for basic and expansion) 8 slots (for basic ) 8 slots (for expansion) 0.6 m 2m Part number Not insulated Voltage: 1 to 5 V, -10 to +10 V Current: 4 to 20 mA, -20 to +20 mA Insulated Voltages, currents, thermocouples, resistance thermometer devices R.T.D. type: Pt 100, JPt 100, JPt 1000 type Voltage range: -10 to +10 V Current range: 0 to 20 mA Resolution: 1/4096 AFP5209 Note: Please refer to “FPΣ Product Types” for FP Memory Loader. Product name Product number Specification Product name FP2 Positioning unit RTEX Product name Expansion memory unit FP2 Multi-wire link unit Controllable I/O points Specification Can connect as the remote I/O system MEWNET-F master station. Perfect for remote I/O systems using many points Direct connection to SUNX Co., Ltd., S-LINK reduced-wiring system CPU unit with 128 points x 2 channels Direct connection to SUNX Co., Ltd., S-LINK reduced-wiring system CPU unit with 128 points x 2 channels Intelligent units for analog I/O Optional memories for FP2 Product name Product name Notes: 1) Pressure welding socket is supplied. A special tool (part no. AXY52000) is needed for connection. Please purchase separately if you are using a terminal or flat cable socket. 2) Please refer to “FPΣ Product Types” for Motor driver I/F terminal II. 3) Previous FP2 positioning units AFP2430 (FP2-PP2) and AFP2431 (FP2-PP4) are not compatible with the multi-function type FP2 positioning unit. Please contact us. Serial communication and Link-related intelligent units Product name Specification Number of channels Product number Part number 1ch FP2-VE AFP27960 1ch FP2-ET1 AFP2790 − − 1ch FP2-MW AFP2720 2ch FP2-MCU AFP2465 1ch 1ch 1ch FP2-CB232 FP2-CB422 FP2-CB485 AFP2803 AFP2804 AFP2805 2ch FP2-CCU AFP2462 2ch FP2-SDU AFP2460 10 Mbps, 8,192 points/8,192 words, 99 units max. (VE mode), 254 units max. (FL-net), 2,500 m * For FP2SH (Cannot be used for FP2) Ethernet-compatible unit for FP2/FP2SH FP2 ET-LAN unit To be mounted on the CPU backplane Control Configurator ET ET-LAN unit setting software (English) For PLC links FP2 Multi-wire link unit Compatible with MEWNET-W/MEWNET-W2 Up to two blocks to be attached can be selected among RS485, RS232C, and RS422 blocks. FP2 Multi-communication unit General-purpose serial communications, computer links, PLC links (MEWTNET-W0) (For the multi-communication unit) 230 kbps, 15 m max. RS232C block (For the multi-communication unit) 230 kbps, 1,200 m max. RS422 block RS485 block (For the multi-communication unit) For PLC links (MEWNET-W0): 115 kbps, 16 stations, 1,200 m FP2 Computer For 1:1 communication between a PLC and a computer communication unit RS232C x 2 ch Connection with a control panel is also possible. For communications with general-purpose RS232C devices FP2 Serial data unit The serial input/output is executed by sequence commands. FP2 MEWNET VE-link unit AAFPS32510 Control FPWIN GR for Windows Product name FPWIN GR for Windows Type English: Full type English: Small type English: Ver. up type Chinese Chinese: Ver. up type Korean CD-ROM for Windows CD-ROM for Windows CD-ROM for Windows CD-ROM for Windows CD-ROM for Windows CD-ROM for Windows Part number AFPS10520 AFPS11520 AFPS10520R AFPS10820 AFPS10820R AFPS10920 FP-X FPΣ A A A A FP0 FP-e A A A A A • Applicable PLC FP0 FP1*1 FP2 10k A A A A A N/A A A A FP2SH FP-M*1 FP3*1 FP10SH • A N/A A A A N/A A A A A: Available, N/A: Not available *1 FP1, FP-M, and FP3/FP10SH have been discontinued. Control FPWIN Pro (IEC61131-3 compliant Windows version software) Product name FPWIN Pro for Windows Type English: Full type English: Small type *1: Ver. 5.1 or later will be supported soon. *2: FP1, FP-M, and FP3/FP10SH have been discontinued. CD-ROM for Windows CD-ROM for Windows Part number FP-X FPΣ AFPS50550 AFPS51550 A A A A FP0 FP-e A A • Applicable PLC FP0 FP1*1 FP2 10k A A A A A N/A FP2SH A N/A FP3*1 FP-M*1 FP10SH • A A A N/A A: Available, N/A: Not available 19                                    !" ## $ %     & # #' ! (     & # #' !"      . / -  /  0  1  23/45%   6  7  ARCT1B283E 200703 )     *+,   -   *        $
FP2-EM6 价格&库存

很抱歉,暂时无法提供与“FP2-EM6”相匹配的价格&库存,您可以联系我们找货

免费人工找货