FX-300 Fiber Optic Sensors
High Performance Digital Fiber Sensor
The FX-300 series of digital fiber optic sensors offers a wide range of sensing possibilities in a compact, high-performance
unit. Three types are available for optimal application coverage including the standard type (FX-301), high-function type (FX305), and the high-speed type (FX-301-HS).
The core of the FX-300 series revolves around five main concepts for superior sensor performance:
●
High Stability
SUNX has developed a system that drastically increases the long and short term stability of their FX-300 series fiber
optic sensors.
❍
Four-Chemical Element LED: Primary to that system is the adoption of a four-chemical element LED light source
that demonstrates unmatched stability in light output over time.
❍
Auto Power Control (APC): To enhance the stability further, SUNX also has integrated an 'Auto Power Control
(APC)' circuit which combats short-term fluctuation in light emission due to ambient conditions.
❍
Double Coupling Lens: These two features are then used to their full advantage by adding a double coupling lens
to focus the emitted light, impressively increasing the overall efficiency and detection distance of the sensor.
●
Superior Performance
The FX-300 series has incorporated several functions that improve on the performance of pervious models.
❍
Light Output Level Selection: The new light output emission function allows for the user to adjust the light output
intensity without effecting the response time of the sensor. This is great for applications that are inhibited by close
range sensing that result in an over-saturation of the sensor.
❍
Large Four Digit Display: The large 4-digit display also increases the saturation point to 9999 to provide better
sensing at close range.
❍
High Speed: Ultra fast response times are also available with the high-speed type, FX-301-HS. Demonstrating a 35microsecond response time, this can handle the most demanding speed requirements.
❍
New Operating Modes: By using the window comparator mode and the differential sensing mode, users can
now perform sensing operations that once needed two sensors and complex threshold settings.
❍
Five Timer Types: In addition to the ON-Delay, OFF-Delay, and ONE-SHOT timers that are found in many
conventional fiber sensors, the SUNX FX-300 series incorporates combination timers: ON+OFF Delay and ONDelay+ONE-SHOT
❍
Multi-Purpose Dual Output:Two independent discrete outputs are available (FX-305) so that one sensor can be
used to control tasks that previously required two sensors. In addition, the secondary output can be used for simple
self-diagnosis or an alarm output so that ease on maintenance is improved.
●
Easy Operation
The FX-300 series was designed around ease of use. The incorporation of a user-friendly jog-dial simplifies operation
and maintenance. Beginners and advanced users alike will benefit from the intuitive programming and operation, thus,
keeping the learning curve to a minimum.
❍
Mode NAVI: Six easy-to-see indicators surround the main display allowing quick and easy confirmation of the
operating mode. Also, the threshold value can be conveniently checked at the touch of a button.
❍
Key Lock Function: The key lock function is a very useful feature in avoiding accidental changes to the sensor
settings. The jog switch as well as the mode button is disabled to prevent any unwanted modifications.
●
Easy Maintenance
SUNX has developed several new features/accessories that simplify sensor maintenance so you spend less time
configuring the sensor and more time using it.
❍
New Communication Unit: The new SC-GU1-485 communication unit allows for complete remote access to
sensor settings. Functions such as teaching and data bank switching can now be performed via a PLC. All sensor
attributes, including incident light readings and threshold values, can also be conveniently checked without requiring
access to the sensor amplifier. This is great for applications where the sensor may not be easily accessible for
maintenance operations. The RS-485 based communication unit allows for 16 sensors per node, and up to 31
nodes. It is now possible to remotely control up to 496 sensors!
❍
External Input Unit: The FX-CH2 external input unit is useful when full access to all sensor functions is not
necessary. This unit allows for external teaching and data bank switching for up to 16 sensors at one time.
❍
Easy Wiring: The easy quick-connect wiring of the FX-300 series allows for any unit to be set up as a main or a
sub unit, simply by changing the wire. The removable wiring also salvages the sensor in the event that the wiring is
accidentally severed. This allows the user to just replace the wire, not the entire sensor.
❍
Optical Communication Function: The optical communication function makes it easy to copy settings to up to 16
sensors connected together. This saves the time of setting up each sensor individually.
❍
Quick Set-Up Code: Restoring settings has never been easier than with the quick set-up code that is built into the
FX-300 series. Once initial set-up is completed, write down the four digit code and in the event that sensor settings
are reset, the user can quickly restore the sensor back to operation.
●
Eco-Friendly
❍
Pb Free: SUNX promotes the use of lead-free materials in all of its sensor manufacturing processes including those
used for the FX-300 series of digital fiber sensors.
❍
Reduced Power Consumption (ECO Mode): The FX-300 series also had an available Eco-mode that reduces the
power consumption from 960mW to 600mW by turning off the display during operation.
SUNX offers a complete line of over 180 different fiber heads to suit any of your detection needs, including diffuse-reflective
(FD Series), retro-reflective (FR Series), and thru-beam (FT Series) types.
Model Name
Type
Emitting
Element
Supply
Voltage
Output
Configuration
Output
Operation
Teaching
Method
Number Of
Outputs
Sort
Sort
Sort
Sort
Sort
Sort
Sort
Sort
FX-301
Standard Type
Red LED
12-24VDC
NPN
Light-ON/DarkAutomatic
ON
1
FX-301P
Standard Type
Red LED
12-24VDC
PNP
Light-ON/DarkAutomatic
ON
1
FX-305
High Function
Type
Red LED
12-24VDC
NPN
Light-ON/DarkAutomatic
ON
2
FX-300
DIMENSIONS (Unit: mm in)
FX-301
FX-305
Amplifier
8.3
Operation indicator
(Note 1)(Orange) 0.327
48.2
26.3 1.898
1.0352.5
0.098
12
0.472
0.7
0.028
Stability indicator
(Note 2)(Green)
MODE key
Jog switch
Digital display (Red)
10
0.394
3
0.118
Beamemitting
part
7 0.276
Beamreceiving
part
64.5
2.539
Communication
window
30.5
1.201
10.5
0.413
7 0.276
3
0.118
3.3
0.130
7
0.276
27.8
1.094
13.5
0.531
(Note 3)
3.95
0.156
Suitable for 35 mm
1.378 in width DIN rail
36.5
1.437
Notes: 1) FX-305; Output 1 operation indicator (Orange)
2) FX-305; Output 2 operation indicator (Orange)
3) FX-301; 3-pin, FX-305; 4-pin
CN-73-C
CN-74-C
CN-71-C
CN-72-C
Main cable (Optional)
• Length (L)
Model No.
L
(Note 2)
Length (mm in)
CN-73/74-C1
1,000
39.370
CN-73/74-C2
2,000
78.740
CN-73/74-C5
5,000 196.850
"3 "0.118 cable
14
(0.551
)
2.54
0.100
2.9
(0.114
)
50
1.969
10
0.394
6
0.236
( )
• Length (L)
Model No.
CN-71/72-C1
1,000
39.370
CN-71/72-C2
2,000
78.740
CN-71/72-C5
5,000 196.850
2.54
0.100
2.54
0.100
2.65
0.104
Notes: 1) CN-74-C only
2) CN-74-C: 4-core
50
1.969
L
Length (mm in)
12 10.5
(0.472
) 0.413
(Note 1)
Sub cable (Optional)
(Note 2)
"3 "0.118 cable
3
14
0.118
0.551
2.9
0.114
(
)
(
)
10
0.394
6
0.236
( )
12 10.5
(0.472
) 0.413
(Note 1)
0.2
0.008
7
0.276
10
0.394
13.6
0.535
3
0.118
7.2
0.283
2.65
0.104
2.54
0.100
Notes: 1) CN-72-C only
2) CN-72-C: 2-core
0.2
0.008
7
0.276
10
0.394
13.6
0.535
3
0.118
7.2
0.283
FX-300
SPECIFICATIONS
Item
Model No.
Type
Standard type
High-speed
Green LED Infrared LED type
High-function type
Red LED
Blue LED
NPN output
FX-301
FX-301B
FX-301G
FX-301H
FX-301-HS
FX-305
PNP output
FX-301P
FX-301BP
FX-301GP
FX-301HP
FX-301P-HS
FX-305P
12 to 24 V DC
10 % Ripple P-P 10 % or less
Supply voltage
Power consumption
Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) ECO mode: 430 mW or less (Current consumption 18 mA or less at 24 V supply voltage)
Output
NPN open-collector transistor
• Maximum sink current:100 mA (50 mA, if five, or more, amplifiers are connected in cascade.)
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less [at 100 mA (at 50 mA, if five, or more, amplifiers are connected in cascade) sink current.]
PNP open-collector transistor
• Maximum source current: 100 mA (50 mA, if five, or more, amplifiers are connected in cascade.)
• Applied voltage: 30 V DC or less (between output and V)
• Residual voltage: 1.5 V or less [at 100 mA (at 50 mA, if five, or more, amplifiers are connected in cascade) source current.]
Incorporated
Short-circuit protection
35 !s or less (H-SP),
65 !s or less [H-SP (Red LED type only)], 150 !s or less (FAST), 150 !s or less (FAST),
250 !s or less (STD / S-D),
250 !s or less [STD / S-D (Red LED type only)],
2 ms or less (LONG),
2 ms or less (LONG), selectable with jog switch
selectable with jog switch
65 !s or less (H-SP), 150 !s or less (FAST),
250 !s or less (STD), 700 !s or less (STDF),
2.5 ms or less (LONG), 4.5 ms or less (U-LG),
selectable with jog switch
2-level teaching / Limit teaching / Manual adjustment /
Full-auto teaching / Max. sensitivity teaching
Normal mode: 2-level teaching / Limit teaching / Full-auto teaching /
Max. sensitivity teaching / Manual adjustment
Window comparator mode: Teaching (1-level / 2-level / 3-level) / Manual adjustment
Sensitivity setting
Orange LED (lights up when the output is ON)
Operation indicator
Stability indicator
Green LED (lights up under stable light received condition or stable dark condition)
RUN: Green LED, TEACH ADJ L/D ON TIMER PRO: Yellow LED
MODE indicator
4 digit red LED display
Digital display
Incorporated
Fine sensitivity adjustment function
Timer function
Light emitting amount selection
function
Environmental resistance
Automatic interference
prevention function
Ambient temperature
PNP open-collector transistor 2 outputs
• Maximum source current: 50 mA each (Note 1)
• Applied voltage: 30 V DC or less (between output and V)
• Residual voltage: 1.5 V or less [at 50 mA (Note 1)]
Selectable either Light-ON or Dark-ON, with jog switch
Output operation
Response time
NPN open-collector transistor 2 outputs
• Maximum sink current: 50 mA each (Note 1)
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less [at 50 mA (Note 1)]
Incorporated with variable ON-delay / OFF-delay / ONE-SHOT timer,
switchable either effective or ineffective.
Timer period: Red LED type; 0.5 ms approx., 1 ms to 9999 ms
(Blue LED, Green LED, Infrared LED type; approx. 0.5 ms to 500 ms)
[
Incorporated (Red LED type only)(Note 2)
FAST, STD, LONG: 4 level, H-SP: 3 level, S-D: 2 level
]
Incorporated with variable ON-delay / OFF-delay /
ONE-SHOT / ON-delay • OFF-delay / ON-delay • ONESHOT timer, switchable either effective or ineffective.
(Timer period: Output 1; 0.5 ms, 1 ms to 9999 ms, Output 2; 0.5 ms, 1 ms to 500 ms)
Incorporated (Note 2)
FAST, STD, STDF, LONG, U-LG: 4 level
H-SP: 3 level
Incorporated (Note 2)
FAST, STD, LONG: 4 level
H-SP, S-D: 2 level
Incorporated [Up to four sets of fiber heads can be
mounted close together. (However, U-LG mode is 8
fiber heads, H-SP mode is 2 fiber heads.)] (Note 4)
Incorporated (Up to four sets of fiber heads can be mounted
close together. However, H-SP mode is 2 fiber heads.)(Note 3)
10 to 55 C 14 to 131 F (If 4 to 7 units are connected in cascade: 10 to 50 C 14 to 122 F, if 8 to 16 units are connected
in cascade: 10 to 45 C 14 to 113 F (No dew condensation or icing allowed), Storage: 20 to 70 C 4 to 158 F
35 to 85 % RH, Storage: 35 to 85 % RH
Ambient humidity
Sunlight: 10,000 ?x at the light-receiving face, Incandescent light: 3,000 ?x at the light-receiving face
Ambient illuminance
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 5)
Voltage withstandability
Insulation resistance
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 5)
Vibration resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each
Shock resistance
Emitting element (modulated)
Material
Connecting method
Cable extension
Weight
Red LED
Blue LED
Green LED
Infrared LED
Red LED
Red LED
Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, MODE key: Acrylic, Jog switch: Heat-resistant ABS (FX-301B/G/H: Acrylic)
Connector (Note 6)
Extension up to total 100 m 328.084 ft (50 m 164.042 ft for 5 to 8 units, 20 m 65.617 ft for 9 to 16 units) is possible with 0.3 mm2, or more, cable.
Net weight: 20 g approx., Gross weight: 25 g approx.
Notes: 1) 50 mA per output. 25 mA if five, or more, amplifiers are connected in cascade.
2) The light emitting amount can be zero (emission halt) in all modes.
3) When the power supply is switched on, the light emission timing is automatically set for interference prevention.
’ is set, the number of mountable fiber heads becomes double. Furthermore, take care that the response time also becomes double.
4) When the interference prevention function ‘
5) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
6) The cable for amplifier connection is not supplied as an accessory. Make sure to use the optional quick-connection cables given below.
Main cable (3-core) for FX-301(P)(-HS): CN-73-C1 (Cable length 1 m 3.281 ft), CN-73-C2 (Cable length 2 m 6.562 ft), CN-73-C5 (Cable length 5 m 16.404 ft)
Sub cable (1-core) for FX-301(P)(-HS): CN-71-C1 (Cable length 1 m 3.281 ft), CN-71-C2 (Cable length 2 m 6.562 ft), CN-71-C5 (Cable length 5 m 16.404 ft)
Main cable (4-core) for FX-305(P): CN-74-C1 (Cable length 1 m 3.281 ft), CN-74-C2 (Cable length 2 m 6.562 ft), CN-74-C5 (Cable length 5 m 16.404 ft)
Sub cable (2-core) for FX-305(P): CN-72-C1 (Cable length 1 m 3.281 ft), CN-72-C2 (Cable length 2 m 6.562 ft), CN-72-C5 (Cable length 5 m 16.404 ft)