FX-301

FX-301

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SENSOR THROUGH-BEAM NPN OPEN COL

  • 详情介绍
  • 数据手册
  • 价格&库存
FX-301 数据手册
Compact Photoelectric Sensor 245 Amplifier Built-in CX-400 SERIES Ver.2 FIBER SENSORS Related Information LASER SENSORS General terms and conditions.............. F-3 Selection guide............................... P.231~ MS-AJ / CHX-SC2...............P.953 / P.959 Glossary of terms......................... P.1549~ General precautions..................... P.1552~ Korea’s S-mark.............................. P.1602 PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Recognition AREA SENSORS Certified (Some models only) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS panasonic.net/id/pidsx/global STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS PNP output type available Light intensity monitor Interference prevention Sensors that are environmentally and user friendly. Reducing environmental burdens further Up to 60% less power consumption The various lineup covers through the inclusion of a newly developed custom integrated circuit.The CX-400 series achieves reductions in power consumption of up to 60%, averaging 44% reduction when upgrading due to its unique design. These sensors reduce carbon emissions and contribute to environmental friendliness. Providing stable detection with low power consumption Includes an analog CMOS processor ASIC Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated EX-Z Upgrade for up to 60 CX-400 CY-100 % reduction EX-10 Strong against oil and coolant liquids CX-41□/42□/49□ The lens material for the thru-beam type, retroreflective type (excluding the CX-48□) and the diffuse reflective type are made of a strong acrylic that resists the harmful effects of coolants. These sensors can be used with confidence even around metal processing machinery that disperses oil mists. The protection mechanism also conforms to IP67 (IEC). Test Oil JIS Standard Product Name Lubricant - Velocity Oil No. 3 Water-insoluble cutting oil 2-5 Daphnecut AS-30D 2-11 Yushiron Oil No.2ac (Note) W1-1 Yushiron Lubic HWC68 (Note) W2-1 Yushiroken S50N (Note) Water-soluble cutting oil 1,000 hours; Immersion (depth 0 m); Insulation resistance 20 MΩ/250 V Note: Yushiron and Yushiroken are registered trademarks of Yushiro Chemical Industry Co., Ltd. EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 Previous CX-482 25 mA Strong against ethanol New CX-482 10 mA Contributing to reduced carbon dioxide emissions Electricity consumed by the CX-400 series has been reduced on average 10.5 mA. Calculating 8 hours/day, 260 days (operating 5 days/week) for a total of 2,080 hours/year leads to: The CX-400 contributes Approx. 84.6 t annually in carbon dioxide reductions to the world CX-44□/48□ A strong, ethanol resistant polycarbonate was used for the front and display covers. Safe even for installing near food processing machinery that disperses ethanol based detergents. The protection mechanism also conforms to IP67 (IEC). Caution: Set the CX-48□ so that cleaning liquid will not get on to the attached reflector. Compact Photoelectric Sensor CX-400 SERIES Ver.2 APPLICATIONS 246 FIBER SENSORS Detecting out of position tape feeder cassette Detecting objects in dusty environment Passage confirmation of object on a conveyor belt LASER SENSORS PHOTOELECTRIC SENSORS CX-412 MICRO PHOTOELECTRIC SENSORS AREA SENSORS Slit mask CX-491 Out of position CX-411 Detecting transparent glass bottles Detecting a small tablet Detecting a biscuit SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS CX-441 CX-443 SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES CX-481 LASER MARKERS PLC BASIC PERFORMANCE Strong infrared beam CX-412/413 Remarkable penetrating power enables applications such as package content detection. Can sense differences as small as 0.4 mm 0.016 in, CX-441/443 with hysteresis of 2 % or less An advanced optical system provides sensing performance that is 2.5 times approx. than conventional models. Even ultra-small differences of 0.4 mm 0.016 in can be detected accurately. HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 2.5 times the sensing capability! Note: When sensing utilizing penetrating power, make sure to verify using the actual sensor. Hardly affected by colors CX-441/443 Both black and white objects can be sensed at the same distances. No adjuster control is needed, even when products of different colors are moving along the production line. Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated Height differences of as little as 0.4 mm 0.016 in can be detected at a setting distance of 20 mm 0.787 in Retroreflective type with polarizing filters CX-491 Built-in polarizing filters ensure stable sensing even on a specular object. EX-Z CX-400 CY-100 EX-10 EX-20 EX-30 30 % higher sensing capability EX-40 CX-440 EQ-30 EQ-500 MQ-W CX-491 The difference in sensing ranges is 1% or less between non-glossy white paper with a setting distance of 50 mm 1.969 in and non-glossy gray paper with a brightness level of 5. RX-LS200 RX RT-610 247 Compact Photoelectric Sensor FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS CX-400 SERIES Ver.2 BASIC PERFORMANCE Our unique optical system and transparent object sensing circuitry provide stable sensing of even thinner transparent objects than the conventional models. AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Twice the sensing range! PARTICULAR USE SENSORS CX-482 SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES Long sensing range of 5 m 16.4 ft Transparent objects detectable with CX-48□ (Typical examples) Sensing object Sensing object size (mm in) Glass sheet 50 × 50 1.969 × 1.969 t = 0.7 0.028 Cylindrical glass ø50 ø1.969 ℓ = 50 1.969 t = 1.3 0.051 Acrylic board 50 × 50 1.969 × 1.969 t = 1.0 0.039 Styrol (Floppy case) 50 × 50 1.969 × 1.969 t = 0.9 0.035 Food wrapping film 50 × 50 1.969 × 1.969 t = 10 µm 0.394 mil Cigarette case film 50 × 50 1.969 × 1.969 t = 20 µm 0.787 mil Vinyl sack 50 × 50 1.969 × 1.969 t = 30 µm 1.181 mil PET bottle (500mℓ) ø66 ø2.598 Reflector setting range CX-481: 300 to 500 mm 11.811 to 19.685 in, CX-482: 1 to 2 m 3.281 to 6.562 ft [with the RF-230 reflector at the optimum condition (Note)] Each object should pass across the beam at the center between the sensor and the reflector. ℓ: Length of cylindrical glasses t: Thickness of sensing object Note: The optimum condition is defined as the condition in which the sensitivity level is set such that the stability indicator just lights up when the object is absent. SENSOR OPTIONS WIRE-SAVING SYSTEMS CX-48□ Introducing the transparent object sensing type sensor CX-493 Ultra-long sensing range of 30 m 98.4 ft CX-413 The CX-413 achieves the ultra-long sensing range of 30 m 98.4 ft. It can be used for a stacker crane or a multilevel parking structure. A long 5 m 16.4 ft sensing range is possible with the red LED type that is easy to align with the beam axis. Can be used for wide automatic door shutters. ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated EX-Z CX-400 CY-100 EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 ENVIRONMENTAL RESISTANCE Strong on dust and dirt CX-412/413 Because the light source is an infrared light, it is strong on dust and dirt compared to the red beam type. Strong even in cold environments Stronger noise resistance The CX-400 series has a higher noise resistance than its previons model. By incorporating an inverter countermeasure circuit that appropriately shifts with peak wavelength, the sensor now resists high-frequency noise from high-voltage inverter motors and inverter lights more effectively. Fluorescent light Stable performance can be maintained even in environments of –25 °C –13 °F. ECO Thoroughly eliminating unnecessary waste, Reducing many environmental burdens The CX-400 series has three different cable length types and uses very simple packaging to reduce waste. The bag is made of polyethylene and does not emit toxic gasses. Inverter motor Compact Photoelectric Sensor CX-400 SERIES Ver.2 MOUNTING Beam axis alignment made easy with a high luminance spot beam CX-423 The bright spot makes beam axis alignment easy CX-44□ These sensors have a high luminance red LED spot beam which provides bright visibility enabling the sensing position to be checked at a glance. Because it achieved small beam spot approx. ø2 mm ø0.079 in at setting distance 100 mm 3.937 in, approx. ø5 mm ø0.197 in at setting distance 200 mm 7.874 in, even the minutest object can be accurately detected. These sensors have a high luminance red spot that provides bright visibility. The sensing position can be checked at a glance. Because the CX-441 sensor has the smallest spot in its class ø2 mm ø0.079 in approx., even the minutest object can be accurately detected. CX-423 Great visibility approx. ø2 mm ø0.079 in high luminance spot beam (at setting distance 100 mm 3.937 in) 248 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Great visibility approx. ø2 mm ø0.079 in high luminance spot CX-441 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS OPERABILITY Reduction of volume adjustment labor CX-42□ Can be used for sensing minute differences CX-44□ Because these sensors possess many variations depending on the sensing range, enables you to make optimal volume adjustment easily. Equipped with a 5-turn adjuster so that even challenging range settings can be handled with ease. SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES CX-422: 800 mm 31.496 in CX-421: 300 mm 11.811 in CX-424: 100 mm 3.937 in LASER MARKERS PLC HUMAN MACHINE INTERFACES Narrow-view type ENERGY MANAGEMENT SOLUTIONS CX-423: 70 to 300 mm 2.756 to 11.811 in FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS VARIETIES Basic type available Select from 2 spot diameters as per the application CX-441/443 Omit the sensitivity adjuster and operation mode switch and release a basic type cable 0.5 m 1.641 ft in length. If the usage is clear, quick construction can be performed onsite without detailed adjustments and the cost can be controlled. Within the choice of 50 mm 1.969 in sensing range sensors, we offer small spot approx. ø2 mm ø0.079 in type optimal for detecting minute object and large approx. ø6.5 mm ø0.256 in spot type capable of sensing object covered with holes and grooves. Less processing time M8 plug-in connector type and M12 pigtailed type are available. This contributes to less time spent in setting up. In addition, cable types are available with cable lengths of 0.5 m 1.640 ft, 2 m 6.562 ft and 5 m 16.404 ft. This results in less wastage. EX-Z CX-400 CY-100 EX-10 EX-20 No unnecessary cables or terminal blocks CX-441 Cable type 5 m 16.404 ft Great maintainability 2 m 6.562 ft M8 plug-in connector type ft / ( 25 mm 6.562 16.404 ft ) ft / ( 25 mm 6.562 16.404 ft ) Elbow Straight 0.5 m 1.640 ft M12 pigtailed type Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated Straight Spot diameter: ø2 mm ø0.079 in approx. [Positioning] Detects minute holes. CX-443 Spot diameter: ø6.5 mm ø0.256 in approx. Detection of presence / absence of objects Ignores minute holes and accurately detects objects. EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 ft / ( 25 mm 6.562 16.404 ft ) 249 Compact Photoelectric Sensor FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS CX-400 SERIES Ver.2 FUNCTIONS CX-44□ BGS/FGS functions make even the most challenging settings possible! For details on the operation of the BGS/FGS functions, refer to “BGS/FGS functions (p.267)” of “PRECAUTIONS FOR PROPER USE”. The BGS function is best suited for the following case The FGS function is best suited for the following case Background not present When object and background are separated Background present When object and background are close together When the object is glossy or uneven BGS FGS Unaffected by gloss, color or uneven surfaces when sensing objects present on a conveyor belt. Not affected if the background color changes or someone passes behind the conveyor. PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS Caution: Please use the FGS function together with a conveyor or other background unit. BGS (Background suppression) function The sensor judges that an object is present when light is received at position A of the light-receiving element (2-segment element). This is useful if the object and background are far apart. The distance adjustment method is the same as the conventional adjustment method for adjustable range reflective type sensors. MACHINE VISION SYSTEMS OFF Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated Background UV CURING SYSTEMS Light received at element B, or light not received Element A Object EX-20 EX-30 EX-40 CX-440 EQ-30 MQ-W RX RT-610 OFF A Object present For glossy object ON ON Emitting element B Lens Setting distance Conveyor Light received at position B A conveyor or other back-ground must be present Strong against interference The interference prevention function lets two sensors to be mounted close together precisely. Interference prevention filter (Optional) Retroreflective type Diffuse reflective type Adjustable range reflective type EQ-500 RX-LS200 Object absent ON in all other conditions Setting distance CX-400 EX-10 OFF in this condition only ON EX-Z CY-100 The sensor judges that an object is present when no light is received at position B of the light-receiving element (2- segment element). Accordingly, even objects that are glossy can be sensed. This is useful if the object and background are close together, or if the object being sensed is glossy. (Light received at element A) Element B Moving object in the back FGS (Foreground suppression) function Thru-beam type Only CX-411 Automatic interference prevention function Conveyor Light received at position A Conveyor Light is not received at position B, so a object is judged to be present Compact Photoelectric Sensor CX-400 SERIES Ver.2 ORDER GUIDE FIBER SENSORS LASER SENSORS Standard type Type Appearance Model No. (Note 1) Sensing range CX-411-P CX-412 CX-412-P CX-413 CX-413-P CX-491 CX-491-P CX-493 CX-493-P 50 to 500 mm 1.969 to 19.685 in (Note 2) CX-481 CX-481-P 50 to 1,000mm 1.969 to 39.37 in (Note 2) CX-483 CX-483-P 0.1 to 2 m 0.328 to 6.562 ft (Note 2) CX-482 CX-482-P MEASUREMENT SENSORS CX-424 CX-424-P STATIC CONTROL DEVICES CX-421 CX-421-P CX-422 CX-422-P CX-423 CX-423-P CX-441 CX-441-P CX-443 CX-443-P CX-444 CX-444-P CX-442 CX-442-P Thru-beam Long sensing range 30 m 98.425 ft Long sensing With polarizing range filters PHOTOELECTRIC SENSORS CX-411 15 m 49.213 ft 3 m 9.843 ft (Note 2) Red LED 300 mm 11.811 in MICRO PHOTOELECTRIC SENSORS AREA SENSORS Infrared LED SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Red LED 5 m 16.404 ft (Note 2) For transparent object sensing Retroreflective Emitting element PNP output 100 mm 3.937 in PARTICULAR USE SENSORS SENSOR OPTIONS Switchable either Light-ON or Dark-ON Infrared LED Infrared LED SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS LASER MARKERS PLC 800 mm 31.496 in Small Narrowspot view Diffuse reflective Output operation NPN output 10 m 32.808 ft Adjustable range reflective 250 70 to 300 mm 2.756 to 11.811 in HUMAN MACHINE INTERFACES Red LED FA COMPONENTS 2 to 50 mm 0.079 to 1.969 in 15 to 100 mm 0.591 to 3.937 in 20 to 300 mm 0.787 to 11.811 in Switchable either Detection-ON or Detection-OFF MACHINE VISION SYSTEMS Red LED NOTE: Mounting bracket is not supplied with the sensor. Please select from the range of optional sensor mounting brackets. Notes: 1) The model No. with “E” shown on the label affixed to the thru-beam type sensor is the emitter, “D” shown on the label is the receiver. 2) The sensing range of the retroreflective type sensor is specified for the RF-230 (optional) reflector. The sensing range represents the actual sensing range of the sensor. The sensing ranges itemized in “A” of the table below may vary depending on the shape of sensing object. Be sure to check the operation with the actual sensing object. Sensing range: A Sensor CX-491□ CX-493□ CX-483□ CX-482□ 50 to 500 mm 50 to 1,000 mm 0.1 to 2 m 1.969 to 19.685 in 1.969 to 39.37 in 0.328 to 6.562 ft Sensing object A 0 to 3 m 0 to 9.843 ft Setting range of the reflector: B B 0.1 to 3 m 0.1 to 5 m 100 to 500 mm 100 to 1,000 mm 0.8 to 2 m 0.328 to 9.843 ft 0.328 to 16.404 ft 3.937 to 19.685 in 3.937 to 39.37 in 2.625 to 6.562 ft Reflector 0 to 5 m 0 to 16.404 ft CX-481□ ENERGY MANAGEMENT SOLUTIONS UV CURING SYSTEMS Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated EX-Z CX-400 CY-100 EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 251 Compact Photoelectric Sensor ORDER GUIDE FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS CX-400 SERIES Ver.2 Basic type (Without operation mode switch and sensitivity adjuster. Cable is 0.5 m 1.640 ft long.) Type Appearance Sensing range MICRO PHOTOELECTRIC SENSORS AREA SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES Thru-beam Retroreflective INDUCTIVE PROXIMITY SENSORS Long sensing range PRESSURE / FLOW SENSORS 15 m 49.213 ft 3 m 9.843 ft (Note 3) FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated EX-Z CX-400 CY-100 EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 CX-411A-C05 CX-411A-P-C05 Light-ON CX-411B-C05 CX-411B-P-C05 Dark-ON CX-412A-C05 CX-412A-P-C05 Light-ON CX-412B-C05 CX-412B-P-C05 Dark-ON CX-491A-C05-Y CX-491A-P-C05-Y Light-ON CX-491B-C05-Y CX-491B-P-C05-Y Dark-ON Optional (Note 2) Emitting element Red LED Infrared LED Red LED NOTE: Mounting bracket is not supplied with the sensor. Please select from the range of optional sensor mounting brackets. Sensing range: A PLC ENERGY MANAGEMENT SOLUTIONS Output operation Notes: 1) The model No. with “E” shown on the label affixed to the thru-beam type sensor is the emitter, “D” shown on the label is the receiver. 2) The reflector is an option. The sensing range of the leflector is specified for the RF-230. 3) The sensing range of the retroreflective type sensor is specified for the RF-230 (optional) reflector (p.253). The sensing range represents the actual sensing range of the sensor. The sensing range : A of the table below may vary depending on the shape of sensing object. Be sure to check the operation with the actual sensing object. LASER MARKERS HUMAN MACHINE INTERFACES PNP output 10 m 32.808 ft With polarizing filters SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Model No.(Note 1) NPN output Sensor CX-491□ Sensing object A 0 to 3 m 0 to 9.843 ft Setting range of the reflector: B B 0.1 to 3 m 0.328 to 9.843 ft Reflector (Optional) Compact Photoelectric Sensor CX-400 SERIES Ver.2 ORDER GUIDE FIBER SENSORS LASER SENSORS 0.5 m 1.640 ft / 5 m 16.404 ft cable length types 0.5 m 1.640 ft / 5 m 16.404 ft cable length types (standard: 2 m 6.562 ft, basic: 0.5 m 1.640 ft) are also available. When ordering this type, suffix “-C05” for the 0.5 m 1.640 ft cable length type, “-C5” for the 5 m 16.404 ft cable length type to the model No. (Excluding CX-44□ and basic type) (e.g.) 0.5 m 1.640 ft cable length type of CX-411-P is “CX-411-P-C05” 5 m 16.404 ft cable length type of CX-411-P is “CX-411-P-C5” PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS M8 plug-in connector type, M12 pigtailed type SAFETY LIGHT CURTAINS / SAFETY COMPONENTS M8 plug-in connector type and M12 pigtailed type are also available. When ordering this type, suffix “-Z” for the M8 connector type, “-J” for the M12 pigtailed type to the model No. (Please note that M12 pigtailed type is not available for CX-44□. Excluding basic type) (e.g.) M8 connector type of CX-411-P is “CX-411-P-Z” M12 pigtailed type of CX-411-P is “CX-411-P-J” PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS • Mating cable (2 cables are required for the thru-beam type.) For M12 pigtailed type For M8 plug-in connector type Type Straight Elbow 2-core 4-core 252 Model No. Cable length CN-24A-C2 2 m 6.562 ft CN-24A-C5 5 m 16.404 ft CN-24AL-C2 2 m 6.562 ft CN-24AL-C5 5 m 16.404 ft CN-22-C2 2 m 6.562 ft CN-22-C5 5 m 16.404 ft CN-24-C2 2 m 6.562 ft CN-24-C5 5 m 16.404 ft Description PARTICULAR USE SENSORS Mating cable • CN-24A-C2 CN-24A-C5 • CN-24AL-C2 CN-24AL-C5 SIMPLE WIRE-SAVING UNITS Can be used with all models For thru-beam type emitter (2-core) WIRE-SAVING SYSTEMS ø9 mm ø0.354 in 31.4 mm 1.236 in 23.1 mm 0.909 in ø9 mm ø0.354 in ø4 mm ø0.157 in Can be used with all models ø4 mm ø0.157 in ø14 mm ø0.551 in • RF-230 (Reflector) 300 mm 11.811 in LASER MARKERS PLC HUMAN MACHINE INTERFACES • CN-22-C2, CN-22-C5 CN-24-C2, CN-24-C5 Accessory MEASUREMENT SENSORS STATIC CONTROL DEVICES 20.5 mm 0.807 in Package without reflector NPN output type: CX-491-Y PNP output type: CX-491-P-Y SENSOR OPTIONS ENERGY MANAGEMENT SOLUTIONS ø5 mm ø0.197 in FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated EX-Z CX-400 CY-100 EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 253 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS Compact Photoelectric Sensor OPTIONS Model No. Designation Slit mask SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS OS-CX-05 () For thrubeam type sensor only WIRE-SAVING SYSTEMS CX-411□ OS-CX-1 CX-411□ CX-411□ OS-CX-05×6 Rectangular slit mask For thrubeam type sensor only () CX-413□ OS-CX-1×6 CX-411□ PLC Interference prevention filter For CX-411□ only Model No. () ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS (Vertical, Silver) 2 pcs. per set PF-CX4-H Reflector () For retroreflective type sensor only Selection Guide EX-Z RF-230(Note 3) CX-440 Sensor CX-481□ CX-483□ MQ-W RX-LS200 RX RT-610 Setting range of the reflector: B Model No. Sensor EQ-30 EQ-500 0.5 × 6 mm 0.020 × 0.236 in 1 × 6 mm 0.039 × 0.236 in 2 × 6 mm 0.079 × 0.236 in 20 mm 0.787 in 600 mm 23.622 in 30 mm 1.181 in Slit on one side Slit on both sides ø12 mm ø0.472 in ø0.5 mm ø0.020 in 1,200 mm 47.242 in 60 mm 2.362 in 900 mm 35.433 in 100 mm 3.937 in 1.35 m 4.429 ft 150 mm 5.906 in 2.7 m 8.857 ft 300 mm 11.811 in 2 m 6.562 ft 400 mm 15.748 in 3 m 9.843 ft 600 mm 23.622 in 6 m 19.685 ft 1,200 mm 47.242 in 2 m 6.562 ft 400 mm 15.748 in 3 m 9.843 ft 600 mm 23.622 in 6 m 19.685 ft 1,200 mm 47.242 in 3 m 9.843 ft 1 m 3.281 ft 4.5 m 14.764 ft 1.5 m 4.921 ft 9 m 29.528 ft 3 m 9.843 ft 5 m 16.404 ft 2 m 6.562 ft 7.5 m 24.606 ft 3 m 9.843 ft 15 m 49.213 ft 6 m 19.685 ft Sensing range Min. sensing object ø12 mm ø0.472 in (Note 1) 5 m 16.404 ft (Note 1) CX-491□ 1 m 3.281 ft (Note 2) CX-493□ 1.5 m 4.921 ft (Note 2) ø1 mm ø0.039 in ø12 mm ø0.472 in ø1.5 mm ø0.059 in ø2 mm ø0.079 in ø12 mm ø0.472 in ø3 mm ø0.118 in ø12 mm ø0.472 in 0.5 × 6 mm 0.020 × 0.236 in ø12 mm ø0.472 in 1 × 6 mm 0.039 × 0.236 in ø12 mm ø0.472 in 2 × 6 mm 0.079 × 0.236 in Round slit mask Round slit mask (Stainless steel) • OS-CX-□ Fitted on the front face of the sensor with onetouch. Rectangular slit mask CX-481□ • OS-CX-□×6 Fitted on the front face of the sensor with onetouch. ø30 mm ø1.181 in CX-483□ 0.1 to 0.3 m 0.328 to 0.984 ft (Note 2) CX-482□ 0.1 to 0.6 m 0.328 to 1.969 ft (Note 2) CX-491□ 1.5 m 4.921 ft (Note 2) CX-493□ 3 m 9.843 ft (Note 2) CX-481□ 50 to 300 mm 1.969 to 11.811 in (Note 2) CX-483□ 0.1 to 0.7 m 0.328 to 2.297 ft (Note 2) CX-482□ 0.1 to 1.3 m 0.328 to 4.265 ft (Note 2) CX-491□-Y□ 3 m 9.843 ft (Note 2) Sensing object EX-10 EX-40 ø2 mm ø0.079 in Slit on both sides 400 mm 15.748 in ø35 mm ø1.378 in Interference prevention filter Rectangular slit mask (Stainless steel) Interference prevention filter • PF-CX4-V (Vertical, Silver) • PF-CX4-H (Horizontal, Light brown) Two sets of CX-411□ can be mounted close together. ø50 mm ø1.969 in Sensing range: A CY-100 EX-30 ø1 mm ø0.039 in Slit on one side Min. sensing object Notes: 1) Value when attached on both sides. 2) Set the distance between the CX-491□/493□ and the reflector to 0.1 m 0.328 ft or more. However, see the table below for CX-48□. The sensing range “A” may vary depending on the shape of sensing object. Be sure to check the operation with the actual sensing object. CX-400 EX-20 ø0.5 mm ø0.020 in Sensing range (Horizontal, Light brown) 2 pcs. per set RF-210 Amplifier Built-in Slit size PF-CX4-V RF-220 Amplifierseparated CX-412□ CX-413□ Designation Power Supply Built-in CX-412□ CX-413□ OS-CX-2×6 LASER MARKERS UV CURING SYSTEMS CX-412□ CX-411□ STATIC CONTROL DEVICES MACHINE VISION SYSTEMS CX-412□ CX-413□ MEASUREMENT SENSORS HUMAN MACHINE INTERFACES CX-412□ CX-413□ OS-CX-2 PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS CX-412□ CX-413□ Round slit mask INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS Sensor CX-411□ MICRO PHOTOELECTRIC SENSORS AREA SENSORS CX-400 SERIES Ver.2 CX-482□ Reflector Reflector • RF-210 Reflector A B RF-220 50 to 300 mm 1.969 to 11.811 in 100 to 300 mm 3.937 to 11.811 in RF-220 0.1 to 0.7 m 0.328 to 2.297 ft 0.2 to 0.7 m 0.656 to 2.297 ft RF-210 0.1 to 0.3 m 0.328 to 0.984 ft 0.1 to 0.3 m 0.328 to 0.984 ft RF-230 0.05 to 1 m 0.164 to 3.281 ft 0.1 to 1 m 0.328 to 3.281 ft RF-220 0.1 to 1.3 m 0.328 to 4.265 ft 0.5 to 1.3 m 1.640 to 4.265 ft RF-210 0.1 to 0.6 m 0.328 to 1.969 ft 0.3 to 0.6 m 0.984 to 1.969 ft 12.8 mm 0.504 in 33.3 mm 1.311 in 3) RF-230 is attached to the retroreflective type sensor other than the basic type. 11 mm 0.433 in • RF-220 35.3 mm 1.390 in 8.3 mm 0.327 in • RF-230 50.3 mm 1.98 in 42.3 mm 1.665 in 59.3 mm 2.235 in 8.3 mm 0.327 in Compact Photoelectric Sensor CX-400 SERIES Ver.2 254 OPTIONS Designation FIBER SENSORS Model No. MS-RF21-1 Reflector mounting bracket • Sensing range (Note 4): 0.7 m 2.297 ft [CX-491□] 1.2 m 3.937 ft [CX-493□] 0.1 to 0.6 m 0.328 to 1.969 ft [CX-482□] RF-12 • Sensing range (Note 5): RF-13 0.5 m 1.640 ft [CX-491□] AREA SENSORS • Ambient temperature: –25 to +50 °C –13 to +122 °F • Ambient humidity: 35 to 85 % RH Notes: 1) K  eep the tape free from stress. If it is pressed too much, its capability may deteriorate. 2) Do not cut the tape. It will deteriorate the sensing performance. • Ambient temperature: –25 to +55 °C –13 to +131 °F • Ambient humidity: 35 to 85 % RH Foot angled mounting bracket It can also be used for mounting RF-210. MS-CX2-1 Sensor checker (Note 3) MS-CX2-4 MS-CX2-5 Back biangled mounting bracket MS-CX-3 Back angled mounting bracket MS-AJ1 Horizontal mounting type MS-AJ2 Vertical mounting type MS-AJ1-A Horizontal mounting type MS-AJ2-A Vertical mounting type MS-AJ1-M Horizontal mounting type MS-AJ2-M Vertical mounting type CHX-SC2 It is useful for beam alignment of thru-beam type sensors. The optimum receiver position is given by indicators, as well as an audio signal. Basic assembly 45˚ Assembly for reflector • MS-AJ1-A 45˚ Elevation angle: ±45˚ Height adjustment: 150 mm 5.906 in approx. Mounting hole for M6 screw • MS-AJ2 45˚ 45˚ Elevation angle: ±45˚ With the lateral arm, the sensor can sense from above a production line. Height adjustment: 150 mm 5.906 in approx. Mounting hole for M6 screw Swivel: 360˚ rotation Forward / back adjustment: 130 mm 5.118 in approx. Height adjustment: 150 mm 5.906 in approx. 45˚ Elevation angle: ±45˚ 360˚ rotation 45˚ 45˚ Angle adjustment: ±45˚ With the lateral arm, the sensor can sense from above a production line. Forward / back adjustment: 130 mm 5.118 in approx. 360˚ rotation SENSOR OPTIONS Reflective tape 30 mm 1.181 in SIMPLE WIRE-SAVING UNITS • RF-12 0.7 mm 0.028 in 8 mm 0.315 in 30 mm 1.181 in 0.7 mm 0.028 in 25 mm 0.984 in STATIC CONTROL DEVICES 0.5 mm 0.020 in 30 mm 1.181 in LASER MARKERS PLC 30 mm 1.181 in HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS Sensor mounting bracket • MS-CX2-1 • MS-CX2-2 45˚ 45˚ Mounting Angle adjustment: ±45˚ hole for M6 screw FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Two M3 (length 12 mm 0.472 in) screws with washers are attached. Two M3 (length 12 mm 0.472 in) screws with washers are attached. • MS-CX2-4 • MS-CX2-5 Selection Guide Amplifier Built-in Power Supply Built-in Height adjustment: 150 mm 5.906 in approx. Amplifierseparated Two M3 (length 14 mm 0.551 in) screws with washers are attached. Two M3 (length 12 mm 0.472 in) screws with washers are attached. • MS-CX-3 EX-Z CX-400 CY-100 EX-10 EX-20 EX-30 • MS-AJ2-M Swivel: 360˚ rotation Height adjustment: 150 mm 5.906 in approx. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Mounting hole for M6 screw Mounting hole for M6 screw PRESSURE / FLOW SENSORS PARTICULAR USE SENSORS Two M4 (length 10 mm 0.394 in) screws with washers are attached. Swivel: 360˚ rotation 45˚ SAFETY LIGHT CURTAINS / SAFETY COMPONENTS INDUCTIVE PROXIMITY SENSORS • MS-AJ1-M • MS-AJ2-A Swivel: 360˚ rotation • MS-RF23 Lateral arm assembly Universal sensor mounting stand Two M3 (length 8 mm 0.315 in) screws with washers are attached. • RF-13 Notes: 1) The plug-in connector type sensor does not allow use of some sensor mounting brackets because of the protrusion of the connector. 2) Refer to p.953~ for the universal sensor mounting stand MS-AJ series. 3) Refer to p.959~ for the sensor checker CHX-SC2. 4) S  et the distance between the sensor and the reflective tape to 0.1 m 0.328 ft (CX-482□: 0.4 m 1.312 ft) or more. 5) Set the distance between the sensor and the reflective tape to 0.2 m 0.656 ft or more. Swivel: 360˚ rotation Two M3 (length 12 mm 0.472 in) screws with washers are attached. • RF-11 Foot biangled mounting bracket It can also be used for mounting RF-210. The thru-beam type sensor needs two brackets. Protective mounting bracket MS-CX2-2 • MS-AJ1 PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS For RF-230 • Sensing range (Note 4): 0.5 m 1.640 ft [CX-491□] 0.8 m 2.625 ft [CX-493□] RF-11 Universal sensor mounting stand (Note 2) • MS-RF22 For RF-220 MS-RF23 Sensor mounting bracket (Note 1) • MS-RF21-1 Protective mounting bracket for RF-210 It protects the reflector from damage and maintains alignment. MS-RF22 Reflective tape LASER SENSORS Reflector mounting bracket Description Swivel: 360˚ rotation 45˚ 45˚ Elevation angle: ±45˚ Height adjustment: 150 mm 5.906 in approx. EX-40 Two M3 (length 12 mm 0.472 in) screws with washers are attached. CX-440 EQ-30 Sensor checker EQ-500 • CHX-SC2 MQ-W PO W Mounting hole for M6 screw ER C H LE VE L X- SC 2 RX-LS200 RX Sensor checker RT-610 255 Compact Photoelectric Sensor SPECIFICATIONS FIBER SENSORS LASER SENSORS Standard type PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Thru-beam Type Model No. MICRO PHOTOELECTRIC SENSORS Item PLC HUMAN MACHINE INTERFACES EMC Directive, RoHS Directive Sensing object ø50 mm ø1.969 in or more opaque, ø12 mm ø0.472 in translucent or or more opaque object (Note 4) specular object (Note 2, 5) Amplifierseparated EX-Z CX-400 CY-100 EX-10 EX-20 EX-30 EX-40 CX-440 Output 13 mA or less 10 mA or less Output operation Short-circuit protection () 0.5 mm 0.020 in or less 13 mA or less 15 mA or less PNP open-collector transistor • Maximum source current: 100 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 2 V or less (at 100 mA source current) 1 V or less (at 16 mA source current) Incorporated 1 ms or less Operation indicator 2 ms or less 1 ms or less Orange LED (lights up when the output is ON)(incorporated on the receiver for thru-beam type) Stability indicator Green LED (lights up under stable light received condition or stable dark condition)(incorporated on the receiver for thru-beam type) Green LED (lights up when the power is ON) (incorporated on the emitter) Power indicator Environmental resistance Opaque, translucent or transparent object (Note 5) Min. sensing object: ø0.5 mm ø0.020 in copper wire Switchable either Light-ON or Dark-ON Response time Continuously variable adjuster (incorporated on the receiver for thru-beam type) Two units of sensors can be mounted close together with interference prevention filters. (Sensing range: 5 m 16.404 ft) Incorporated (Two units of sensors can be mounted close together.) Protection IP67 (IEC) Ambient temperature -25 to +55 °C -13 to +131 °F (No dew condensation or icing allowed), Storage: -30 to +70 °C -22 to +158 °F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 3,000 ℓx or less at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each Shock resistance Emitting element (modulated) Red LED Infrared LED Red LED Peak emission wavelength 680 nm 0.027 mil 870 nm 0.034 mil 850 nm 0.033 mil 680 nm 0.027 mil 650 nm 0.026 mil Material Infrared LED Infrared LED Red LED 870 nm 0.034 mil 860 nm 0.033 mil 645 nm 0.025 mil Enclosure: PBT (Polybutylene terephthalate), Lens: Acrylic (CX-48□: Polycarbonate), Indicator cover: Acrylic (CX-48□: Polycarbonate) Cable 0.2 mm2 3-core (thru-beam type emitter: 2-core) cabtyre cable, 2 m 6.562 ft long Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (thru-beam type: both emitter and receiver) Cable extension Net Weight Emitter: 45 g approx., Receiver: 50 g approx. Gross 50 g approx. 100 g approx. 80 g approx. 60 g approx. RF-230 (Reflector): 1 pc. Accessories Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor. The sensing range : A of the table below may vary depending on the shape of sensing object. Be sure to check the operation with the actual sensing object. Sensing range: A MQ-W RT-610 1 mm 0.039 in or less NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 2  V or less (at 100 mA sink current) 1 V or less (at 16 mA sink current) EQ-500 RX Opaque, translucent or transparent object (Note 5) 12 to 24 V DC ±10 % Ripple P-P 10 % or less Emitter: 15 mA or less Emitter: 20 mA or less Emitter: 25 mA or less Receiver: 10 mA or less Receiver: 10 mA or less Receiver: 10 mA or less Current consumption EQ-30 RX-LS200 ø50 mm ø1.969 in or more transparent, translucent or opaque object (Note 2, 5) 0.5 mm 0.020 in or less Supply voltage Automatic interference prevention function Power Supply Built-in ø50 mm ø1.969 in or more opaque or translucent object (Note 2, 5) 15 % or less of operation distance (Note 3) Repeatability (perpendicular to sensing axis) FA COMPONENTS Amplifier Built-in 30 m 98.425 ft Hysteresis Sensitivity adjuster Selection Guide 15 m 49.213 ft 3 m 9.843 ft 5 m 16.404 ft 50 to 500 mm 50 to 1,000 mm 0.1 to 2 m 100 mm 300 mm 800 mm 70 to 300 mm 1.969 to 19.685 in (Note 2) 1.969 to 39.37 in (Note 2) 0.328 to 6.562 ft (Note 2) 3.937 in (Note 3) 11.811 in (Note 3) 31.496 in (Note 3) 2.756 to 11.811 in (Note 3) (Note 2) (Note 2) Sensing range ENERGY MANAGEMENT SOLUTIONS UV CURING SYSTEMS Narrow-view PNP output CX-411-P CX-412-P CX-413-P CX-491-P CX-493-P CX-481-P CX-483-P CX-482-P CX-424-P CX-421-P CX-422-P CX-423-P 10 m 32.808 ft MACHINE VISION SYSTEMS Diffuse reflective NPN output CX-411 CX-412 CX-413 CX-491 CX-493 CX-481 CX-483 CX-482 CX-424 CX-421 CX-422 CX-423 CE marking directive compliance STATIC CONTROL DEVICES LASER MARKERS Retroreflective Long sensing range With polarizing filters Long sensing range For transparent object sensing WIRE-SAVING SYSTEMS MEASUREMENT SENSORS CX-400 SERIES Ver.2 Sensor CX-491□ CX-493□ Sensing object A 0 to 3 m 0 to 9.843 ft 0 to 5 m 0 to 16.404 ft Setting range of the reflector: B B 0.1 to 3 m 0.1 to 5 m 0.328 to 9.843 ft 0.328 to 16.404 ft CX-481□ CX-483□ CX-482□ 50 to 1,000 mm 50 to 500 mm 1.969 to 19.685 in 1.969 to 39.37 in 0.1 to 2 m 0.328 to 6.562 ft 100 to 500 mm 100 to 1,000 mm 3.937 to 19.685 in 3.937 to 39.37 in 0.8 to 2 m 2.625 to 6.562 ft Reflector 3) The sensing range and hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object. 4) If slit masks (optional) are fitted, an object of ø0.5 mm ø0.020 in (using round slit mask) can be detected. 5) Make sure to confirm detection with an actual sensor before use. Compact Photoelectric Sensor CX-400 SERIES Ver.2 SPECIFICATIONS FIBER SENSORS LASER SENSORS Standard type Model No. Type Item PHOTOELECTRIC SENSORS Adjustable range reflective Small spot NPN output CX-441 CX-443 CX-444 CX-442 MICRO PHOTOELECTRIC SENSORS PNP output CX-441-P CX-443-P CX-444-P CX-442-P AREA SENSORS CE marking directive compliance EMC Directive, RoHS Directive Adjustable range (Note 2) 20 to 50 mm 0.787 to 1.969 in 20 to 100 mm 0.787 to 3.937 in 40 to 300 mm 1.575 to 11.811 in Sensing range (with white non-glossy paper) 2 to 50 mm 0.079 to 1.969 in 15 to 100 mm 0.591 to 3.937 in 20 to 300 mm 0.787 to 11.811 in Hysteresis (with white non-glossy paper) Repeatability Along sensing axis: 1 mm 0.039 in or less, Perpendicular to sensing axis: 0.2 mm 0.008 in or less (with white non-glossy paper) PARTICULAR USE SENSORS Current consumption Output operation PNP open-collector transistor • Maximum source current: 100 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 2 V or less (at 100 mA source current) 1 V or less (at 16 mA source current) Switchable either Detection-ON or Detection-OFF Short-circuit protection 1 ms or less Operation indicator Green LED (lights up under stable operating condition) (Note 3) Distance adjuster 5-turn mechanical adjuster Sensing mode IP67 (IEC) Ambient temperature –25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F Ambient humidity Incandescent light: 3,000 ℓx or less at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max) in X, Y and Z directions for two hours each 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each Shock resistance Emitting element Red LED (Peak emission wavelength: 650 nm 0.026 mil, modulated) ø2 mm ø0.079 in approx. (at 50 mm 1.969 in distance) Material ø6.5 mm ø0.256 in approx. (at 50 mm 1.969 in distance) ø9 mm ø0.354 in approx. (at 100 mm 3.937 in distance) ø15 mm ø0.591 in approx. (at 300 mm 11.811 in distance) Enclosure: PBT (Polybutylene terephthalate), Lens: Polycarbonate, Indicator cover: Polycarbonate 0.2 mm2 4-core cabtyre cable, 2 m 6.562 ft long Cable Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. Cable extension Weight Net weight: 55 g approx., Gross weight: 65 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can detect an object 2 mm 0.079 in [CX-444(-P): 15 mm 0.591 in, CX-442(-P): 20 mm 0.787 in], or more, away. Actual sensing range of the sensor: A Adjustable range: B Sensing object FA COMPONENTS MACHINE VISION SYSTEMS 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS Incorporated Protection MEASUREMENT SENSORS PLC BGS/FGS functions Switchable with wiring of sensing mode selection input Automatic interference prevention function (Note 4) WIRE-SAVING SYSTEMS LASER MARKERS Orange LED (lights up when the output is ON) Stability indicator SIMPLE WIRE-SAVING UNITS STATIC CONTROL DEVICES Incorporated Response time Environmental resistance SENSOR OPTIONS 20 mA or less NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 2  V or less (at 100 mA sink current) 1 V or less (at 16 mA sink current) Spot diameter PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS 12 to 24 V DC ±10 % Ripple P-P 10 % or less Output SAFETY LIGHT CURTAINS / SAFETY COMPONENTS 5 % or less of operation distance 2 % or less of operation distance Supply voltage 256 UV CURING SYSTEMS Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated EX-Z CX-400 CY-100 EX-10 EX-20 CX-441□/443□ CX-444□ CX-442□ EX-30 A 2 to 50 mm 0.079 to 1.969 in 15 to 100 mm 0.591 to 3.937 in 20 to 300 mm 0.787 to 11.811 in EX-40 B 20 to 50 mm 0.787 to 1.969 in 20 to 100 mm 0.787 to 3.937 in 40 to 300 mm 1.575 to 11.811 in 3) Refer to ‘‘Stability indicator (p.267)’’ of ‘‘PRECAUTIONS FOR PROPER USE’’ for operation of the stability indicator. 4) Note that detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object. CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 257 Compact Photoelectric Sensor SPECIFICATIONS FIBER SENSORS LASER SENSORS Basic type PHOTOELECTRIC SENSORS Thru-beam Type AREA SENSORS Item SAFETY LIGHT CURTAINS / SAFETY COMPONENTS CX-411A-C05 CX-411B-C05 CX-412A-C05 CX-412B-C05 CX-491A-C05-Y CX-491B-C05-Y PNP output CX-411A-P-C05 CX-411B-P-C05 CX-412A-P-C05 CX-412B-P-C05 CX-491A-P-C05-Y CX-491B-P-C05-Y EMC Directive, RoHS Directive 10 m 32.808 ft 15 m 49.213 ft ø12 mm ø0.472 in or more opaque object (Note 3) 3 m 9.843 ft (Note 2) ø50 mm ø1.969 in or more transparent, translucent or opaque object (Note 2, 4) 0.5 mm 0.020 in or less 12 to 24 V DC ±10 % Ripple P-P 10 % or less Emitter: 15 mA or less Receiver: 10 mA or less Current consumption STATIC CONTROL DEVICES Emitter: 20 mA or less Receiver: 10 mA or less NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 2  V or less (at 100 mA sink current) 1 V or less (at 16 mA sink current) Output MEASUREMENT SENSORS Short-circuit protection Orange LED (lights up when the output is ON)(incorporated on the receiver for thru-beam type) Stability indicator Green LED (lights up under stable light received condition or stable dark condition)(incorporated on the receiver for thru-beam type) Power indicator HUMAN MACHINE INTERFACES PNP open-collector transistor • Maximum source current: 100 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 2  V or less (at 100 mA source current) 1 V or less (at 16 mA source current) 1 ms or less Operation indicator PLC 13 mA or less Incorporated Response time LASER MARKERS Green LED (lights up when the power is ON) (incorporated on the emitter) Sensitivity adjuster ENERGY MANAGEMENT SOLUTIONS Two units of sensors can be mounted close together with interference prevention filters. (Sensing range: 5 m 16.404 ft) Automatic interference prevention function Environmental resistance FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS IP67 (IEC) Ambient temperature –25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 3,000 ℓx or less at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each Emitting element (modulated) Amplifier Built-in Peak emission wavelength Power Supply Built-in Amplifierseparated Infrared LED Red LED 870 nm 0.034 mil 680 nm 0.027 mil Enclosure: PBT (Polybutylene terephthalate), Lens: Acrylic, Indicator cover: Acrylic Cable 0.2 mm2 3-core (thru-beam type emitter: 2-core) cabtyre cable, 0.5 m 1.640 ft long Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (thru-beam type: both emitter and receiver) Net Weight CX-400 Red LED 680 nm 0.027 mil Material Cable extension EX-Z Incorporated (Two units of sensors can be mounted close together.) Protection Shock resistance Selection Guide Emitter: 20 g approx., Receiver: 20 g approx. 20 g approx. 50 g approx. 30 g approx. Gross Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-230 reflector (optional). The sensing range represents the actual sensing range of the sensor. The sensing range : A of the table below may vary depending on the shape of sensing object. Be sure to check the operation with the actual sensing object. EX-30 Sensing range: A EX-40 CX-440 EQ-30 Sensor EQ-500 RT-610 Dark-ON NPN output Supply voltage WIRE-SAVING SYSTEMS RX Light-ON Hysteresis SIMPLE WIRE-SAVING UNITS MQ-W Dark-ON Repeatability (perpendicular to sensing axis) SENSOR OPTIONS RX-LS200 With polarizing filters Light-ON Sensing object PARTICULAR USE SENSORS EX-20 Long sensing range Dark-ON Sensing range INDUCTIVE PROXIMITY SENSORS Retroreflective Light-ON CE marking directive compliance PRESSURE / FLOW SENSORS EX-10 Model No. MICRO PHOTOELECTRIC SENSORS CY-100 CX-400 SERIES Ver.2 CX-491□ Sensing object A 0 to 3 m 0 to 9.843 ft Setting range of the reflector: B B 0.1 to 3 m 0.328 to 9.843 ft Reflector (Optional) 3) If slit masks (optional) are fitted, an object of ø0.5 mm ø0.020 in (using round slit mask) can be detected. 4) Make sure to confirm detection with an actual sensor before use. Compact Photoelectric Sensor CX-400 SERIES Ver.2 I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS LASER SENSORS NPN output type I/O circuit diagram Sensor circuit Tr Color code / Connector pin No. of the connector type Wiring diagram PHOTOELECTRIC SENSORS Brown (Brown / 1) +V D (Black / 4) Output (Note 1) D ZD ZD Black (Note 1) Load + – 100 mA max. (Blue / 3) 0 V (Pink / 2) Sensing mode selection input (Note 2, 3) Internal circuit 12 to 24 V DC ±10 % Load + – 12 to 24 V DC ±10 % Blue Pink (Note 2, 3) User’s circuit Notes: 1) The emitter of the thru-beam type sensor does not incorporate the black wire. 2) T  he pink wire is incorporated only for the CX-44□ adjustable range reflective type. When using the CX-44□, be sure to wire the pink wire as mentioned *1. Unstable operation may occur. 3) W  hen the mating cable is connected to the plug-in connector type of CX-44□, its color is white. *1 BGS function: Connect to 0 V FGS function: Connect to +V M8 plug-in connector type BGS function: Connect to 0 V FGS function: Connect to +V 2 Sensing mode selection input (Note 2) Symbols ... D : Reverse supply polarity protection diode ZD : Surge absorption zener diode Tr : NPN output transistor 1 2 Not connected 3 0V 1 +V 3 0V 4 Output (Note 1) PNP output type Sensor circuit Color code / Connector pin No. of the connector type Wiring diagram LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS MACHINE VISION SYSTEMS Brown (Brown / 1) +V 100 mA max. (Black / 4) Output (Note 1) (Blue / 3) 0 V Load + – 12 to 24 V DC ±10 % User’s circuit Notes: 1) The emitter of the thru-beam type sensor does not incorporate the output. 2) Sensing mode selection input is incorporated only for the CX-44□-P adjustable range reflective type. When using the CX-44□-P, be sure to wire the sensing mode selection input (pink / 2) as mentioned *1. Unstable operation may occur. 3) When the mating cable is connected to the plug-in connector type of CX-44□-P, its color is white. *1 • Sensing mode selection input BGS function: Connect to 0 V FGS function: Connect to +V Symbols ... D : Reverse supply polarity protection diode ZD : Surge absorption zener diode Tr : PNP output transistor + – Black (Note 1) Load Blue 12 to 24 V DC ±10 % UV CURING SYSTEMS *1 *1 (Pink / 2) Sensing mode selection input (Note 2, 3) Internal circuit MEASUREMENT SENSORS FA COMPONENTS I/O circuit diagram D D PARTICULAR USE SENSORS STATIC CONTROL DEVICES Notes: 1) The emitter of the thru-beam type sensor does not incorporate the output. 2) S  ensing mode selection input is incorporated only for the CX-44□ adjustable range reflective type. When using the CX-44□, be sure to wire the sensing mode selection input (pink / 2). Unstable operation may occur. ZD ZD INDUCTIVE PROXIMITY SENSORS SIMPLE WIRE-SAVING UNITS M12 pigtailed type 4 Output (Note 1) +V PRESSURE / FLOW SENSORS WIRE-SAVING SYSTEMS Connector pin position • Sensing mode selection input AREA SENSORS SENSOR OPTIONS • Sensing mode selection input *1 MICRO PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS *1 *1 Notes: 1) The emitter of the thru-beam type sensor does not incorporate the output. 2) Sensing mode selection input is incorporated only for the CX-44□ adjustable range reflective type. When using the CX-44□, be sure to wire the sensing mode selection input (pink / 2) as mentioned *1. Unstable operation may occur. 3) When the mating cable is connected to the plug-in connector type of CX-44□, its color is white. Tr 258 Pink (Note 2, 3) Selection Guide Notes: 1) The emitter of the thru-beam type sensor does not incorporate the black wire. 2) T  he pink wire is incorporated only for the CX-44□-P adjustable range reflective type. When using the CX-44□-P, be sure to wire the pink wire as mentioned *1. Unstable operation may occur. 3) W  hen the mating cable is connected to the plug-in connector type of CX-44□-P, its color is white. *1 2 Sensing mode selection input (Note 2) 1 +V 4 Output (Note 1) 3 0V Amplifierseparated CX-400 BGS function: Connect to 0 V FGS function: Connect to +V M8 plug-in connector type Power Supply Built-in EX-Z • Sensing mode selection input Connector pin position Amplifier Built-in CY-100 EX-10 M12 pigtailed type 2 Not connected 1 +V EX-20 EX-30 EX-40 CX-440 EQ-30 3 0V 4 Output (Note 1) Notes: 1) The emitter of the thru-beam type sensor does not incorporate the output. 2) S  ensing mode selection input is incorporated only for the CX-44□-P adjustable range reflective type. When using the CX-44□-P, be sure to wire the sensing mode selection input (pink / 2). Unstable operation may occur. EQ-500 MQ-W RX-LS200 RX RT-610 259 SENSING CHARACTERISTICS (TYPICAL) FIBER SENSORS CX-411□ Thru-beam type 0 400 15.748 PARTICULAR USE SENSORS SENSOR OPTIONS Parallel deviation with round slit masks (ø2 mm ø0.079 in) 0 100 3.937 HUMAN MACHINE INTERFACES FA COMPONENTS MACHINE VISION SYSTEMS Power Supply Built-in EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 Setting distance L (mm in) Vertical direction Emitter ℓ L L Angular deviation 20 65.617 15 49.213 15 49.213 10 32.808 Emitter 5 16.404 0 1,000 39.370 2 Horizontal 6.562 direction Emitter 1 3.281 ℓ 20 0 20 40 0.787 0.787 1.575 Center Left Right Operating point ℓ (mm in) Parallel deviation with rectangular slit masks (2 × 6 mm 0.079 × 0.236 in) Slit on one side Horizontal direction 6 19.685 Slit on both sides Horizontal direction Vertical direction Emitter Slit on both sides Vertical direction ℓ L L Slit on one side Vertical direction 4 Slit on both sides Slit on both sides Horizontal 13.123 Horizontal Vertical direction direction direction Emitter Receiver Receiver 0 0 200 100 100 200 7.874 7.874 3.937 3.937 (Down) Left Right (Up) Center Operating point ℓ (mm in) ℓ L Receiver 800 31.496 2 6.562 ℓ θ L 10 32.808 ℓ L Receiver 5 16.404 20 0 20 Center Left Right Operating angle θ( ° ) 1 3.281 0 400 15.748 Slit on both sides Emitter ℓ L Receiver 200 0 200 400 7.874 7.874 15.748 Center Left Right Operating point ℓ (mm in) Slit on one side Slit on one side Horizontal Vertical direction direction 3 9.843 2 6.562 Horizontal direction Emitter 1 3.281 ℓ L Vertical direction Emitter ℓ L Receiver Receiver 0 400 200 0 200 400 15.748 7.874 7.874 15.748 (Down) Left Right (Up) Center Operating point ℓ (mm in) L Receiver Parallel deviation with rectangular slit masks (1 × 6 mm 0.039 × 0.236 in) Horizontal 2 direction 6.562 Emitter ℓ L 1.5 4.921 1 3.281 Emitter 0.5 1.640 ℓ L Receiver Receiver 0 400 200 0 200 400 15.748 7.874 7.874 15.748 (Down) Left Right (Up) Center Operating point ℓ (mm in) L Receiver 100 0 100 200 3.937 3.937 7.874 Center Left Right Operating point ℓ (mm in) Parallel deviation with rectangular slit masks (2 × 6 mm 0.079 × 0.236 in) Slit on one side Slit on one side Horizontal Vertical direction direction 6 19.685 Vertical direction Emitter ℓ Slit on both sides 8 26.247 Slit on one side Slit on one side Vertical Horizontal direction direction Slit on both sides Horizontal and Vertical direction Slit on one side 0 200 7.874 0 50 50 100 1.969 1.969 3.937 Center Left Right Operating point ℓ (mm in) 4 13.123 Slit on both sides Horizontal and Vertical direction ℓ Slit on both sides 0 100 3.937 40 4 13.123 Slit on one side Emitter 200 7.874 4 13.123 2 6.562 L Parallel deviation with round slit masks (ø1 mm ø0.039 in) 2 6.562 400 15.748 Parallel deviation with rectangular slit masks (0.5 × 6 mm 0.020 × 0.236 in) 3 9.843 Vertical direction Emitter Receiver Receiver 0 200 100 100 200 0 7.874 3.937 3.937 7.874 (Down) Left Right (Up) Center Operating point ℓ (mm in) Slit on one side 600 23.622 Emitter 0 40 500 500 1,000 0 19.685 19.685 39.370 Center Left Right Operating point ℓ (mm in) Parallel deviation with round slit masks (ø0.5 mm ø0.020 in) Parallel deviation with round slit masks (ø2 mm ø0.079 in) Setting distance L (m ft) EX-10 Slit on both sides Horizontal direction Receiver 0 40 1.575 8 26.247 Slit on one side Slit on one side Vertical Horizontal direction direction L Thru-beam type 20 65.617 EX-Z CY-100 ℓ Slit on both sides Vertical direction Receiver Receiver 0 0 100 50 50 100 3.937 1.969 1.969 3.937 (Down) Left Right (Up) Center Operating point ℓ (mm in) 50 0 50 100 3.937 1.969 1.969 Center Left Right Operating point ℓ (mm in) Parallel deviation Amplifierseparated CX-400 Receiver Setting distance L (m ft) Amplifier Built-in L Horizontal 1 direction 3.281 Emitter Parallel deviation with rectangular slit masks (1 × 6 mm 0.039 × 0.236 in) Emitter ℓ CX-412□ UV CURING SYSTEMS Selection Guide Emitter ℓ PLC ENERGY MANAGEMENT SOLUTIONS Slit on both sides 1 3.281 Slit on both sides Receiver 3 9.843 Slit on one side Horizontal direction 400 15.748 0 10 10 20 0.787 0.394 0.394 Center Left Right Operating point ℓ (mm in) 4 13.123 Slit on one side Vertical direction 2 6.562 0 20 0.787 40 Parallel deviation with rectangular slit masks (0.5 × 6 mm 0.020 × 0.236 in) Slit on one side 2 6.562 20 0 20 Center Left Right Operating angle θ ( ° ) Slit on one side Setting distance L (m ft) LASER MARKERS 0 40 L ℓ 800 31.496 Setting distance L (m ft) STATIC CONTROL DEVICES Setting distance L (m ft) WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Setting distance L (m ft) Receiver Emitter Slit on both sides 200 7.874 Receiver 200 200 400 0 7.874 7.874 15.748 Center Left Right Operating point ℓ (mm in) Slit on one side Setting distance L (mm in) SIMPLE WIRE-SAVING UNITS L ℓ θ L 5 16.404 Setting distance L (m ft) INDUCTIVE PROXIMITY SENSORS Emitter 5 16.404 400 15.748 Emitter Setting distance L (m ft) PRESSURE / FLOW SENSORS Setting distance L (m ft) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS 10 32.808 10 32.808 Setting distance L (m ft) AREA SENSORS Parallel deviation with round slit masks (ø1 mm ø0.039 in) Setting distance L (mm in) Parallel deviation with round slit masks (ø0.5 mm ø0.020 in) Angular deviation Setting distance L (m ft) Parallel deviation MICRO PHOTOELECTRIC SENSORS Setting distance L (m ft) PHOTOELECTRIC SENSORS Please contact our office for the sensing characteristics of CX-413 and CX-483. Setting distance L (m ft) LASER SENSORS CX-400 SERIES Ver.2 Compact Photoelectric Sensor Slit on both sides Horizontal and Vertical direction 4 Horizontal 13.123 direction Emitter 2 6.562 ℓ L Vertical direction Emitter ℓ L Receiver Receiver 0 800 400 400 800 0 31.496 15.748 15.748 31.496 (Down) Left Right (Up) Center Operating point ℓ (mm in) Compact Photoelectric Sensor SENSING CHARACTERISTICS (TYPICAL) Angular deviation 4 13.123 4 13.123 Reflector (RF-230) ℓ 2 6.562 L 1 3.281 1 3.281 0 200 7.874 Sensor angular deviation Reflector (RF-230) θ L 2 6.562 Sensor 0 40 100 0 100 200 3.937 3.937 7.874 Center Left Right Operating point ℓ (mm in) CX-481□ θ 20 0 20 Center Left Right Operating angle θ ( ° ) Setting distance L (mm in) Setting distance L (mm in) 400 15.748 ℓ Sensor 200 7.874 Sensor Reflector angular Reflector deviation angular Reflector (RF-230) deviation 200 7.874 0 40 50 0 50 100 1.969 1.969 3.937 Center Left Right Operating point ℓ (mm in) 6 19.685 0 200 7.874 40 Sensor angular deviation Reflector (RF-230) θ L 400 15.748 L 6 19.685 Reflector (RF-230) ℓ L Sensor angular deviation θ L Sensor 20 0 20 Center Left Right Operating angle θ ( ° ) 40 CX-482□ 0 20 0.787 Sensing range L (mm in) Setting distance L (mm in) 50 1.969 L Sensor 100 3.937 a × a mm White non-glossy paper 50 1.969 0 200 × 200 mm 7.874 × 7.874 in White nonglossy paper ℓ L Sensor SENSOR OPTIONS WIRE-SAVING SYSTEMS 2 6.562 2 6.562 Reflector (RF-230) 1 3.281 0 200 7.874 ℓ L Sensor 100 0 100 200 3.937 3.937 7.874 Center Left Right Operating point ℓ (mm in) 1 3.281 0 40 MEASUREMENT SENSORS Sensor angular deviation Sensor angular deviation θ L Reflector (RF-230) Sensor Reflector angular deviation Reflector angular deviation Reflector θ L (RF-230) Sensor 20 0 20 Center Left Right Operating angle θ ( ° ) 40 STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS As the sensing object size becomes smaller than the standard size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the sensing range shortens, as shown in the left graph. For plotting the left graph, the sensitivity has been set such that a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just detectable at a distance of 100 mm 3.937 in. MACHINE VISION SYSTEMS UV CURING SYSTEMS Amplifier Built-in 50 100 150 1.969 3.937 5.906 White non-glossy paper side length a (mm in) 200 7.874 Power Supply Built-in Amplifierseparated As the sensing object size becomes smaller than the standard size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the sensing range shortens, as shown in the left graph. For plotting the left graph, the sensitivity has been set such that a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just detectable at a distance of 300 mm 11.811 in. 400 15.748 300 11.811 200 7.874 a × a mm White nonglossy paper 100 3.937 L 0 PARTICULAR USE SENSORS Selection Guide 50 100 150 1.969 3.937 5.906 White non-glossy paper side length a (mm in) EX-Z CX-400 CY-100 EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 Sensor 20 0 20 40 0.787 0.787 1.575 Center Left Right Operating point ℓ (mm in) INDUCTIVE PROXIMITY SENSORS SIMPLE WIRE-SAVING UNITS Angular deviation Correlation between sensing object size and sensing range 100 3.937 0 40 1.575 Sensor Sensor 20 0 20 40 Center Left Right Operating angle θ( ° ) Diffuse reflective type Sensing range L (mm in) Setting distance L (mm in) 200 7.874 PRESSURE / FLOW SENSORS Sensor Sensing field 300 11.811 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Retroreflective type CX-421□ 400 15.748 Sensor Sensor angular deviation Reflector (RF-230) θ L AREA SENSORS Reflector angular deviation Sensor angular deviation Reflector angular deviation Reflector (RF-230) θ L L 10 0 10 20 0.394 0.394 0.787 Center Left Right Operating point ℓ (mm in) LASER SENSORS MICRO PHOTOELECTRIC SENSORS Correlation between sensing object size and sensing range 200 × 200 mm 7.874 × 7.874 in White non-glossy paper FIBER SENSORS PHOTOELECTRIC SENSORS Diffuse reflective type Sensing field ℓ 2 6.562 0 40 100 0 100 200 3.937 3.937 7.874 Center Left Right Operating point ℓ (mm in) CX-424□ 100 3.937 4 13.123 Sensor Parallel deviation 600 23.622 Reflector (RF-230) 8 26.247 Sensor 800 31.496 600 23.622 8 26.247 2 6.562 L Angular deviation 800 31.496 Angular deviation 4 13.123 Retroreflective type Parallel deviation 0 100 3.937 Sensor angular deviation Reflector angular deviation Reflector (RF-230) Sensor Parallel deviation Setting distance L (m ft) 3 9.843 Setting distance L (m ft) Setting distance L (m ft) 3 9.843 Reflector angular deviation Retroreflective type Setting distance L (m ft) Parallel deviation CX-493□ Setting distance L (m ft) Retroreflective type 260 Please contact our office for the sensing characteristics of CX-413 and CX-483. Setting distance L (m ft) CX-491□ CX-400 SERIES Ver.2 EQ-500 200 7.874 MQ-W RX-LS200 RX RT-610 261 Compact Photoelectric Sensor SENSING CHARACTERISTICS (TYPICAL) FIBER SENSORS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS 1,000 39.370 SIMPLE WIRE-SAVING UNITS 200 × 200 mm 7.874 × 7.874 in White nonglossy paper ℓ 500 19.685 LASER MARKERS 200 7.874 Amplifier Built-in Power Supply Built-in Amplifierseparated EX-Z CX-400 CY-100 EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 50 100 150 1.969 3.937 5.906 White non-glossy paper side length a (mm in) 200 7.874 As the sensing object size becomes smaller than the standard size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the sensing range shortens, as shown in the left graph. White 200 7.874 N6 100 200 × 200 mm 3.937 7.874 × 7.874 in Non-glossy paper 100 3.937 ℓ L Sensor 0 2 0.079 For plotting the left graph, the sensitivity has been set such that a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just detectable at a distance of 200 mm 7.874 in. Contact us for the sensing characteristics of 300 mm 11.811 in distance. Please contact us for the sensing field at the setting distance 300 mm 11.811 in. N6 a × a mm Non-glossy paper L Sensor 1 0 1 2 0.039 0.039 0.079 Center Left Right Operating point ℓ (mm in) 0 50 100 150 1.969 3.937 5.906 Non-glossy paper side length a (mm in) 200 7.874 Correlation between lightness and sensing range Sensing range L (mm in) 200 7.874 Sensing region 100 3.937 Selection Guide 0 Correlation between sensing object size and sensing range FA COMPONENTS UV CURING SYSTEMS Sensor White HUMAN MACHINE INTERFACES MACHINE VISION SYSTEMS L Diffuse reflective type Sensing field PLC ENERGY MANAGEMENT SOLUTIONS a × a mm White nonglossy paper 400 15.748 CX-423□ Setting distance L (mm in) STATIC CONTROL DEVICES As the sensing object size becomes smaller than the standard size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the sensing range shortens, as shown in the left graph. For plotting the left graph, the sensitivity has been set such that a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just detectable at a distance of 800 mm 31.496 in. 800 31.496 20 0 20 40 0.787 0.787 1.575 Center Left Right Operating point ℓ (mm in) WIRE-SAVING SYSTEMS MEASUREMENT SENSORS L Sensor 0 40 1.575 PARTICULAR USE SENSORS SENSOR OPTIONS Correlation between sensing object size and sensing range 0 Dark N2 N4 N6 Lightness N8 The sensing region is represented by oblique lines in the left figure. However, the sensitivity should be set with an enough margin because of slight variation in products. Emitted beam 250 9.843 200 7.874 150 5.906 110 4.331 100 3.937 ø2.5 mm ø0.098 in ø2 mm ø0.079 in ø2.2 mm ø0.087 in 50 1.969 ø4 mm ø0.157 in 0 Light N1 N2 N3 N4 N5 N6 N7 N8 N9 Lightness shown on the left may differ slightly from the actual object condition. ø5 mm ø0.197 in Visible spot range SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Sensing field Distance L (mm in) AREA SENSORS Diffuse reflective type Sensing range L (mm in) MICRO PHOTOELECTRIC SENSORS CX-422□ Sensing range L (mm in) PHOTOELECTRIC SENSORS Setting distance L (mm in) LASER SENSORS CX-400 SERIES Ver.2 Compact Photoelectric Sensor CX-400 SERIES Ver.2 SENSING CHARACTERISTICS (TYPICAL) FIBER SENSORS CX-441□ Adjustable range reflective type Sensing fields 80 3.150 Gray non-glossy paper Lightness: 5 30 1.181 20 0.787 60 2.362 50 × 50 mm 1.969 × 1.969 in Non-glossy paper 10 0.394 ℓ L 4 0.157 Gray non-glossy paper Lightness: 5 50 × 50 mm 1.969 × 1.969 in Non-glossy paper 20 0.787 Sensor 0 White nonglossy paper 40 1.575 0 4 0.157 2 0 2 4 0.079 0.079 0.157 Center Left Right Operating point ℓ (mm in) MICRO PHOTOELECTRIC SENSORS 80 3.150 L ℓ Sensor SAFETY LIGHT CURTAINS / SAFETY COMPONENTS ø2 mm 0.079 in ø2 mm 0.079 in PRESSURE / FLOW SENSORS ø3 mm 0.118 in INDUCTIVE PROXIMITY SENSORS ø3 mm 0.118 in 0 2 0 2 4 0.079 0.079 0.157 Center Left Right Operating point ℓ (mm in) Correlation between color (50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range AREA SENSORS 60 2.362 50 1.969 40 1.575 30 1.181 20 0.787 Distance L (mm in) Setting distance L (mm in) White nonglossy paper Setting distance L (mm in) • Setting distance: 50 mm 1.969 in 40 1.575 LASER SENSORS PHOTOELECTRIC SENSORS Emitted beam • Setting distance: 25 mm 0.984 in 262 PARTICULAR USE SENSORS SENSOR OPTIONS Correlation between material (50 × 50 mm 1.969 × 1.969 in) and sensing range SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS 25 0.984 Black rubber 0 Plywood mm …25 0.984 in Cardboard Black Blue Gray Green Red Brown Orange White 0 Yellow mm …25 0.984 in Gray non-glossy paper (Lightness: 5) 25 0.984 mm …50 1.969 in White nonglossy paper mm …50 1.969 in 50 1.969 Sensing range L (mm in) Sensing range L (mm in) 50 1.969 These bars indicate the sensing range with the respective colors when the distance adjuster is set to a sensing range of 50 mm 1.969 in and 25 mm 0.984 in long, respectively, with white color. The sensing range also varies depending on material. CX-443□ 2 0 2 4 0.079 0.079 0.157 Center Left Right Operating point ℓ (mm in) 0 4 0.157 Gray non-glossy paper Lightness: 5 Correlation between color (50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range Sensing range L (mm in) 50 1.969 mm …50 1.969 in 25 0.984 Black Gray Blue Green Brown Red Orange White 0 Yellow mm …25 0.984 in These bars indicate the sensing range with the respective colors when the distance adjuster is set to a sensing range of 50 mm 1.969 in and 25 mm 0.984 in long, respectively, with white color. The sensing range also varies depending on material. HUMAN MACHINE INTERFACES FA COMPONENTS Selection Guide ø6.2 mm 0.244 in ø5.9 mm 0.232 in Amplifier Built-in ø5.3 mm 0.209 in Power Supply Built-in Amplifierseparated 0 2 0 2 4 0.079 0.079 0.157 Center Left Right Operating point ℓ (mm in) PLC ø6.5 mm 0.256 in EX-Z Correlation between material (50 × 50 mm 1.969 × 1.969 in) and sensing range 50 1.969 mm …50 1.969 in 25 0.984 mm …25 0.984 in 0 Black rubber 4 0.157 White nonglossy paper 60 2.362 50 1.969 40 1.575 30 1.181 20 0.787 Plywood 0 20 0.787 Sensor Cardboard Gray non-glossy paper Lightness: 5 10 0.394 ℓ Gray non-glossy paper (Lightness: 5) 40 1.575 White nonglossy paper L White nonglossy paper 60 2.362 LASER MARKERS UV CURING SYSTEMS 80 3.150 50 × 50 mm 1.969 × 1.969 in Non-glossy paper Distance L (mm in) ℓ Sensor 20 0.787 80 3.150 Sensing range L (mm in) L 30 1.181 • Setting distance: 50 mm 1.969 in Setting distance L (mm in) Setting distance L (mm in) 50 × 50 mm 1.969 × 1.969 in Non-glossy paper STATIC CONTROL DEVICES MACHINE VISION SYSTEMS Emitted beam • Setting distance: 25 mm 0.984 in MEASUREMENT SENSORS ENERGY MANAGEMENT SOLUTIONS Adjustable range reflective type Sensing fields 40 1.575 These bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 50 mm 1.969 in and 25 mm 0.984 in long, respectively, with white non-glossy paper. These bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 50 mm 1.969 in and 25 mm 0.984 in long, respectively, with white non-glossy paper. CX-400 CY-100 EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 263 Compact Photoelectric Sensor SENSING CHARACTERISTICS (TYPICAL) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Sensing fields White nonglossy paper 30 1.181 20 0.787 • Setting distance: 50 mm 1.969 in • Setting distance: 100 mm 3.937 in 80 3.150 40 1.575 Gray non-glossy paper Lightness: 5 50 × 50 mm 1.969 × 1.969 in Non-glossy paper L 0 10 0.394 SENSOR OPTIONS ℓ 40 1.575 Gray non-glossy paper Lightness: 5 0 10 0.394 5 0 5 10 0.394 0.197 0.197 Center Left Right Operating point ℓ (mm in) 100 3.937 50 × 50 mm 1.969 × 1.969 in Non-glossy paper 20 0.787 Sensor White nonglossy paper White nonglossy paper 60 2.362 10 0.394 PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS Emitted beam • Setting distance: 25 mm 0.984 in ℓ L Setting distance L (mm in) AREA SENSORS Adjustable range reflective type Setting distance L (mm in) MICRO PHOTOELECTRIC SENSORS CX-444□ Setting distance L (mm in) PHOTOELECTRIC SENSORS Gray non-glossy paper Lightness: 5 50 × 50 mm 1.969 × 1.969 in Non-glossy paper 50 1.969 ℓ L Sensor Sensor 0 10 0.394 5 0 5 10 0.197 0.197 0.394 Center Left Right Operating point ℓ (mm in) Correlation between color (50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range 100 3.937 ø9 mm ø0.354 in 80 3.150 ø8 mm ø0.315 in 50 1.969 ø6.5 mm ø0.256 in 20 0.787 ø5.3 mm ø0.209 in Distance L (mm in) FIBER SENSORS LASER SENSORS CX-400 SERIES Ver.2 0 5 0 5 10 0.197 0.197 0.394 Center Left Right Operating point ℓ (mm in) Correlation between material (50 × 50 mm 1.969 × 1.969 in) and sensing range WIRE-SAVING SYSTEMS Emitted beam White nonglossy paper 200 7.874 50 × 50 mm 1.969 × 1.969 in Non-glossy paper 50 1.969 0 10 0.394 EX-Z RT-610 300 mm …11.811 in 200 mm …7.874 in …100 mm 3.937 in 100 3.937 0 50 × 50 mm 1.969 × 1.969 in Non-glossy paper 100 3.937 L 0 10 0.394 5 0 5 10 0.197 0.197 0.394 Center Left Right Operating point ℓ (mm in) # ℓ Sensor 5 0 5 10 0.197 0.197 0.394 Center Left Right Operating point ℓ (mm in) 300 11.811 □15 mm □0.591 in 200 7.874 □11 mm □0.433 in 100 3.937 1.181 30 □9 mm □0.354 in ø8 mm ø0.315 in 0 Correlation between material (50 × 50 mm 1.969 × 1.969 in) and sensing range These bars indicate the sensing range with the respective colors when the distance adjuster is set to a sensing range of 300 mm 11.811 in, 200 mm 7.874 in and 100 mm 3.937 in long, respectively, with white color. The sensing range also varies depending on material. 300 11.811 200 7.874 300 mm …11.811 in 200 mm …7.874 in …100 mm 3.937 in 100 3.937 0 Black rubber RX 0 10 0.394 200 7.874 Plywood MQ-W RX-LS200 # ℓ White nonglossy paper 300 11.811 Cardboard EQ-500 200 7.874 Black EQ-30 Gray CX-440 L Sensor 300 11.811 Blue EX-40 50 × 50 mm 1.969 × 1.969 in Non-glossy paper 400 15.748 Gray non-glossy paper Lightness: 5 400 15.748 Green EX-30 Gray non-glossy paper Lightness: 5 400 15.748 Brown EX-20 Red EX-10 100 3.937 • Setting distance: 300 mm 11.811 in 400 15.748 White nonglossy paper Correlation between color (50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range White CY-100 5 0 5 10 0.197 0.197 0.394 Center Left Right Operating point ℓ (mm in) Sensing range L (mm in) CX-400 ℓ L Sensor Orange Amplifierseparated Gray non-glossy paper Lightness: 5 Yellow Power Supply Built-in Setting distance L (mm in) Amplifier Built-in • Setting distance: 200 mm 7.874 in Distance L (mm in) • Setting distance: 100 mm 3.937 in 100 3.937 Selection Guide Plywood Sensing fields Gray non-glossy paper (Lightness: 5) UV CURING SYSTEMS These bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 100 mm 3.937 in and 50 mm 1.969 in long, respectively, with white non-glossy paper. Adjustable range reflective type White nonglossy paper MACHINE VISION SYSTEMS CX-442□ Setting distance L (mm in) FA COMPONENTS Black rubber ENERGY MANAGEMENT SOLUTIONS 0 Cardboard Black Blue Gray Green Red Brown Orange White Yellow 0 HUMAN MACHINE INTERFACES mm …50 1.969 in Gray non-glossy paper (Lightness: 5) mm …50 1.969 in PLC mm …100 3.937 in 50 1.969 White nonglossy paper mm …100 3.937 in Sensing range L (mm in) 50 1.969 100 3.937 Setting distance L (mm in) LASER MARKERS These bars indicate the sensing range with the respective colors when the distance adjuster is set to a sensing range of 100 mm 3.937 in and 50 mm 1.969 in long, respectively, with white color. The sensing range also varies depending on material. Sensing range L (mm in) STATIC CONTROL DEVICES 100 3.937 Sensing range L (mm in) MEASUREMENT SENSORS These bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 300 mm 11.811 in, 200 mm 7.874 in and 100 mm 3.937 in long, respectively, with white non-glossy paper. Compact Photoelectric Sensor PRECAUTIONS FOR PROPER USE CX-400 SERIES Ver.2 264 Refer to p.1552~ for general precautions. LASER SENSORS All models PHOTOELECTRIC SENSORS • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS Mounting • The tightening torque should be 0.5 N·m or less. INDUCTIVE PROXIMITY SENSORS M3 (length 12 mm 0.472 in) screw with washers Sensor mounting bracket (Optional) PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Others • Do not use during the initial transient time (50 ms) after the power supply is switched on. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS CX-41□   CX-42□   CX-49□   CX-48□ Part description and functions STATIC CONTROL DEVICES Beam alignment Stability indicator (Green) (Note 1) Lights up under the stable light condition or the stable dark condition Operation indicator (Orange) (Note 2) Lights up when the sensing output is ON Sensitivity adjuster (Note 1) Sensing range becomes longer when turned. Operation mode switch (Note 1) L: Light-ON D: Dark-ON Notes: 1) Not incorporated on the emitter. 2) It is the power indicator (green, lights up when the power is ON. ) on the emitter. Operation mode switch Operation mode switch FIBER SENSORS Description Light-ON mode is obtained when the operation mode switch (thru-beam type incorporate it in the receiver ) is turned fully clockwise (L side). Dark-ON mode is obtained when the operation mode switch (thru-beam type incorporate it in the receiver ) is turned fully counterclockwise (D side). LASER MARKERS Thru-beam type 1. Set the operation mode switch to the Light-ON mode position (L side). 2. Place the emitter and the receiver face to face along a straight line, move the emitter in the up, down, left and right directions, in order to determine the range of the light received condition with the help of the operation indicator (orange). Then, set the emitter at the center of this range. 3. Similarly, adjust for up, down, left and right angular movement of the emitter. Sensing object 4. Further, perform the angular adjustment for the receiver also. 5. C heck that the stability indicator (green) lights up. 6. Choose the operation mode, LightEmitter ON or Dark-ON, as per your requirement, with the operation mode switch. Receiver PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Retroreflective type 1. Set the operation mode switch to the Light-ON mode position (L side). 2. Placing the sensor and the reflector face to face along a straight line, move the reflector in the up, down, left and right directions, in order to determine the range of the light received condition with the help of the operation indicator (orange). Then, set the reflector at the center of this range. 3. Similarly, adjust for up, down, left and right angular movement of the reflector. 4. Further, perform the angular adjustment for the sensor also. 5. Check that the stability indicator Sensing object (green) lights up. 6.  C hoose the operation mode, Light-ON or Dark-ON, as per your requirement, with the operation mode switch. Reflector Sensor Power Supply Built-in Amplifierseparated EX-Z CX-400 CY-100 EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 265 Compact Photoelectric Sensor PRECAUTIONS FOR PROPER USE FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Sensitivity adjustment PRESSURE / FLOW SENSORS A PARTICULAR USE SENSORS SENSOR OPTIONS B A 3 WIRE-SAVING SYSTEMS MEASUREMENT SENSORS A 4 MACHINE VISION SYSTEMS The position at the middle of points is the optimum sensing position. and Note: Use the flathead screwdriver (purchase separately) to turn the adjuster slowly. Turning with excessive strength will cause damage to the adjuster. ENERGY MANAGEMENT SOLUTIONS Light condition Emitter Dark condition Emitter Receiver Thru-beam type Receiver Sensing object UV CURING SYSTEMS Sensor Reflector Sensor Retroreflective type Reflector Sensing object Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated Diffuse reflective type Sensor EX-20 EX-30 In case of Light-ON Operation indicator Output EX-40 CX-440 ON EQ-30 EQ-500 MQ-W OFF RX-LS200 RX RT-610 , : Lights up, Glossy surface • If a shiny object is covered or wrapped with a transparent film, such as those described below, the retroreflective type sensor with polarizing filters may not be able to detect it. In that case, follow the steps given below. • Can wrapped by clear film • Aluminum sheet covered by plastic film • Gold or silver color (specular) label or wrapping paper Steps • Tilt the sensor with respect to the sensing object while fitting. • Reduce the sensitivity. • Increase the distance between the sensor and the sensing object. CX-48□ Retroreflective type sensor for transparent object sensing (CX-48□) • Optimum sensing is possible when the position of the transparent sensing object is set at the center of the sensor and the reflector. If the sensing position is set near the sensor or the reflector, the sensing may be unstable. In this case, set the sensing position at the center of the sensor and the reflector. Sensor Sensing condition Stable light receiving Unstable light receiving Unstable dark receiving Stable dark receiving : Turns OFF Reflector Transparent sensing object Relation between output and indicators Stability indicator Reflector 10° to 30° Retroreflective type sensor with polarizing filters (CX-491□) Sensing object CX-400 EX-10 Sensing object L Sensor EX-Z CY-100 Make L sufficiently long Example of sensing objects B LASER MARKERS FA COMPONENTS In the dark condition, turn the sensitivity adjuster further clockwise until the sensor enters the “Light” state operation and then bring it back to confirm point where the sensor just returns to the “Dark” state operation. If the sensor does not enter the “Light” state operation even when the sensitivity adjuster is turned fully clockwise, the position is point . Optimum position STATIC CONTROL DEVICES Make L, shown in the diagram, sufficiently long. 2 Install at an angle of 10 to 30 degrees to the sensing object. 1 In the light received condition, turn the sensitivity adjuster slowly clockwise and confirm the point where the sensor enters the “Light” state operation. 2 SIMPLE WIRE-SAVING UNITS • Please take care of the following points when detecting materials having a gloss. Description Turn the sensitivity adjuster fully counterclockwise to the minimum sensitivity position, MIN. 1 INDUCTIVE PROXIMITY SENSORS Retroreflective type sensor (excluding CX-491□) Sensitivity adjuster Step SAFETY LIGHT CURTAINS / SAFETY COMPONENTS HUMAN MACHINE INTERFACES Refer to p.1552~ for general precautions. CX-41□  CX-42□  CX-49□  CX-48□ AREA SENSORS PLC CX-400 SERIES Ver.2 In case of Dark-ON Output OFF Operation Stability indicator indicator • When the sensor detects an uneven plastic receptacle or glass bottle, the received-light amount may differ with the sensing position or direction. Adjust the sensitivity after confirming the stable sensing condition by turning the sensing object, etc. • When sensing pipe-shaped transparent sensing object, set it in a standing, not lying, position as shown in Figure A. The sensor may fail to detect a lying object as shown in Figure B. Correct Incorrect A B ON Sensor Reflector Sensor Reflector Compact Photoelectric Sensor PRECAUTIONS FOR PROPER USE CX-400 SERIES Ver.2 266 Refer to p.1552~ for general precautions. FIBER SENSORS LASER SENSORS CX-41□ Slit mask (Optional) Interference prevention filter (CX-411□) PHOTOELECTRIC SENSORS • With the slit mask OS-CX-□, the sensor can detect a small object. However, the sensing range is reduced when the slit mask is mounted. • By mounting the interference prevention filters PF-CX4-□, two sets of the CX-411□ can be mounted close together. However, the sensing range is reduced when the interference prevention filter is mounted. How to mount • The filters can be mounted by the same method as for the slit masks. SAFETY LIGHT CURTAINS / SAFETY COMPONENTS • Since there are two types of the interference prevention filter, the two sets of sensors should be fitted with different types of interference prevention filters, as shown in the figure below. The interference prevention does not work even if the filters are mounted for emitters only, receivers only or the same model No. of the interference prevention filters are mounted on both the sets of the sensor. PRESSURE / FLOW SENSORS 1. Insert the fixing hook into the fixing groove. 2. Then, pressing the slit mask against the main unit, insert the fixing tab into the fixing groove. Fixing groove Fixing tab Removing tab AREA SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS PF-CX4-H (Horizontal, Light brown) WIRE-SAVING SYSTEMS Fixing groove Slit mask MICRO PHOTOELECTRIC SENSORS MEASUREMENT SENSORS Fixing hook STATIC CONTROL DEVICES How to remove LASER MARKERS 1. Insert a screwdriver into the removing tab. 2. Pull forward while lifting the removing tab. PF-CX4-V (Vertical, Silver) PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS CX-44□ Mounting • Care must be taken regarding the sensor mounting direction with respect to the object’s direction of movement. Correct Correct Sensing object Sensing object Operation mode switch Sensing object FA COMPONENTS Description Detecting-ON mode is obtained when the operation mode switch is turned fully clockwise (L side). Incorrect Do not make the sensor detect an object in this direction because it may cause unstable operation. • When detecting a specular object (aluminum or copper foil, etc.) or an object having a glossy surface or coating, please take care that there are cases when the object may not be detected due to a change in angle, wrinkles on the object surface, etc. • When a specular body is present below the sensor, use the sensor by tilting it slightly upwards to avoid wrong operation. Incorrect Operation mode switch Not detecting-ON is obtained when the operation mode switch is turned fully counterclockwise (D side) Note: Use the flathead screwdriver (purchase separately) to turn the operation mode switch slowly. Turning with excessive strength will cause damage to the adjuster. • Depending on whether you select the BGS or FGS function, the output operation changes as follows. Correct Sensing range MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated EX-Z CX-400 CY-100 Setting distance EX-10 EX-20 Non-detectable area EX-30 Specular face Tilt • If a specular body is present in the background, wrong operation may be caused due to a small change in the angle of the background body. In that case, install the sensor at an inclination and confirm the operation with the actual sensing object. • Take care that there is a non-detectable area right in front of the sensor. EX-40 L-ON ON OFF D-ON ON OFF EQ-30 L-ON ON OFF MQ-W D-ON ON OFF BGS FGS CX-440 EQ-500 RX-LS200 RX RT-610 267 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PRECAUTIONS FOR PROPER USE SIMPLE WIRE-SAVING UNITS Stability indicator When using the BGS function • Since the CX-44□ use a 2-segment photodiode as its receiving element, and sensing is done based on the difference in the incident beam angle of the reflected beam from the sensing object, the output and the operation indicator (orange) operate according to the object distance. Further, the stability indicator (green) shows the margin to the setting distance. Sensor Setting distance STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated EX-Z CX-400 CY-100 EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 Description 1 Turn the distance adjuster fully counterclockwise to the minimum sensing range position. (CX-441□/443□/444□: 20 mm 0.787 in approx., CX-442□: 40 mm 1.575 in approx.) 2 Place an object at the required distance from the sensor, turn the distance adjuster gradually clockwise, and find out point A where the sensor changes to the detecting condition. 3 Remove the object, turn the adjuster clockwise further until the sensor goes into the detecting state again. Once it has entered, turn the distance adjuster backward until the sensor returns to the non-detecting condition. This position is designated as point B . When the sensor does not go into the detecting condition even if the adjuster is turned fully clockwise, the position where the adjuster was fully turned is regarded as the point B . There may be more than 1 turn between point A and B , since this sensor incorporates a 5-turn adjuster. Stability indicator 4 The optimum position to stably detect objects is the center point between A and B . OFF (Lights off) Stable operating condition Lights up Stable operating condition Lights off Unstable operating condition BGS/FGS functions • This sensor incorporates BGS/FGS functions. Select either BGS or FGS function depending on the positions of the background and sensing object. BGS function • This function is used when the sensing object is apart from the background. Sensing object FA COMPONENTS UV CURING SYSTEMS Step ON (Lights up) Output (operation indicator) (BGS mode, In case of Detection-ON) ENERGY MANAGEMENT SOLUTIONS MACHINE VISION SYSTEMS Sensing object WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Refer to p.1552~ for general precautions. CX-44□ PARTICULAR USE SENSORS SENSOR OPTIONS CX-400 SERIES Ver.2 Turn fully Optimum position • Follow only steps 1 and 2 . Since the sensing point may change depending on the sensing object, be sure to check the operation with the actual sensing object. When using the FGS function FGS function • This function is used when the sensing object contacts the background or the sensing object is glossy, etc. • Please use the FGS function together with a conveyor or other background unit. Distance adjuster Background FIBER SENSORS Compact Photoelectric Sensor • Please use the FGS function together with a conveyor or other background unit. Step Sensing object 1 Background Distance adjustment • When this product is used, be sure to carry out the distance adjustment. • Since the distance adjuster of this sensor is a 5-turn adjuster, when the point A and B is adjusted as explained in the table right, there may be more than 1 turn between the point A and B . Therefore, make sure to remember the turns of both points to find the optimum position. • Be sure to wire the sensing mode selection input (Pink / 2) before distance adjustment. If the wiring is done after the distance adjustment, the sensing area is changed. • Turn the distance adjuster gradually and lightly with a “minus” screwdriver (purchase separately). In order to protect itself, the distance adjuster idles if turned fully. If the adjuster is idled when distance adjustment is done, carry out the adjustment again. 2 Description Turn the distance adjuster fully clockwise to the maximum sensing range position. (CX-441□/443□: 50 mm 1.969 in approx., CX-444□: 100 mm 3.937 in approx., CX-442□: 300 mm 11.811 in approx.) In the state where the sensor detects the background, turn the distance adjuster gradually counterclockwise, and find out point A where the sensor changes to the non-detecting condition. 3 Place an object at the required distance from the sensor, turn the adjuster counterclockwise further until the sensor goes into the non-detecting condition again. Once entered, turn the distance adjuster backward until the sensor returns to the detecting condition. This position is designated as point B . When the sensor does not go into the non-detecting condition even if the adjuster is turned fully counterclockwise, the position where the adjuster was fully turned is regarded as the point B . There may be more than 1 turn between point A and B , since this sensor incorporates a 5-turn adjuster. 4 The optimum position to stably detect objects is the center point between A and B . Distance adjuster Turn fully Optimum position Others • Its distance adjuster is mechanically operated. Do not drop; avoid other shocks. Compact Photoelectric Sensor DIMENSIONS (Unit: mm in) Sensor Operation indicator (Orange)(Note 2) Beam axis Operation mode switch (Note 1) 20 0.787 3 0.118 ø3.7 ø0.146 cable, 2 m 6.562 ft long (Note 4) 3-core (emitter: 2-core) × 0.2 mm2 insulator diameter: ø1.2 ø0.047 Notes: 1) Not incorporated on the emitter and the basic type sensor. 2) It is the power indicator (green) on the emitter. 3) Not incorporated on the emitter. 4) Basic type: 0.5 m 1.640 ft long CX-41□-J Sensor Sensitivity adjuster (Note 1) Operation indicator (Orange)(Note 2) Stability indicator (Green)(Note 1) Beam axis ( Operation indicator (Orange) 2-M3 × 0.5 0.020 thru-hole threads ø3.7 ø0.146 cable SENSOR OPTIONS M8 connector 11.8 0.465 WIRE-SAVING SYSTEMS Center of sensing 2-M3 × 0.5 0.020 thru-hole threads HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS 2.3 (0.091 ) 15.5 0.610 25.4 31 1.220 1.000 4 0.157 Beam-emitting part PLC 20 0.787 3 0.118 11.2 0.441 STATIC CONTROL DEVICES LASER MARKERS 7.85 0.309 3.95 0.156 Operation mode switch (Note 1) MACHINE VISION SYSTEMS ø3.7 ø0.146 cable, 2 m 6.562 ft long (Note 2) UV CURING SYSTEMS 3-core × 0.2 mm2 insulator diameter: ø1.2 ø0.047 300 (11.811 ) Notes: 1) Not incorporated on the emitter. 2) It is the power indicator (green) on the emitter. SIMPLE WIRE-SAVING UNITS Sensor Stability indicator (Green) 4 0.157 ) M12 connector 44 (1.732 ) PARTICULAR USE SENSORS CX-49□  CX-48□  CX-42□ Beam-receiving part 2.3 0.091 INDUCTIVE PROXIMITY SENSORS MEASUREMENT SENSORS Operation mode switch (Note 1) 15.5 0.610 31 25.4 1.220 1.000 PRESSURE / FLOW SENSORS Notes: 1) Not incorporated on the emitter. 2) It is the power indicator (green) on the emitter. 7.85 0.309 3.95 0.156 20 0.787 3 0.118 11.2 0.441 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS 2.3 ( 0.091 ) 2-M3 × 0.5 0.020 thru-hole threads Sensitivity adjuster (Note 1) 11.8 0.465 AREA SENSORS 15.5 31 0.610 25.4 1.220 1.000 35.5 1.398 42.5 1.673 ø9.4 ø0.370 LASER SENSORS MICRO PHOTOELECTRIC SENSORS 7.85 0.309 3.95 0.156 20 0.787 3 0.118 Beam axis FIBER SENSORS PHOTOELECTRIC SENSORS Operation mode switch (Note 1) 11.2 0.441 2-M3 × 0.5 0.020 thru-hole threads 11.8 0.465 Stability indicator (Green)(Note 1) 2.3 (0.091 ) 15.5 0.610 25.4 31 1.220 1.000 Sensor Operation indicator (Orange)(Note 2) 7.85 0.309 3.95 0.156 Stability indicator (Green)(Note 3) 11.2 0.441 CX-41□-Z Sensitivity adjuster (Note 1) 11.8 0.465 268 The CAD data can be downloaded from our website. CX-41□ Sensitivity adjuster (Note 1) CX-400 SERIES Ver.2 Notes: 1) Not incorporated on the Bacic type sensors. 2) Basic type: 0.5 m 1.640 ft long Selection Guide Amplifier Built-in CX-49□-Z  CX-48□-Z  CX-42□-Z Sensitivity adjuster Operation indicator (Orange) Stability indicator (Green) 15.5 0.610 25.4 35.5 31 1.220 42.5 1.398 1.000 1.673 ø9.4 ø0.370 11.8 0.465 2-M3 × 0.5 0.020 thru-hole threads CX-49□-J  CX-48□-J  CX-42□-J Sensitivity adjuster 7.85 0.309 3.95 0.156 Operation indicator (Orange) Operation mode switch 20 0.787 3 0.118 11.2 Beam-receiving 0.441 part Center of sensing 4 4 0.157 0.157 Beam-emitting part Sensor Stability indicator (Green) 11.2 Beam-receiving 0.441 part 4 0.157 2.3 ( 0.091 ) M8 connector 4 0.157 Beam-emitting part Center of sensing 15.5 0.610 31 25.4 1.220 1.000 2-M3 × 0.5 0.020 thru-hole threads Sensor 11.8 0.465 7.85 0.309 3.95 0.156 Power Supply Built-in Amplifierseparated EX-Z CX-400 Operation mode switch 20 0.787 3 0.118 CY-100 EX-10 EX-20 EX-30 ( ) 2.3 0.091 M12 connector 44 (1.732 ) ø3.7 ø0.146 cable 300 (11.811 ) EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 269 FIBER SENSORS LASER SENSORS Compact Photoelectric Sensor CX-400 SERIES Ver.2 DIMENSIONS (Unit: mm in) CX-44□ MICRO PHOTOELECTRIC SENSORS 12.5 0.492 Operation indicator (Orange) Distance adjuster (5-turn) AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Stability indicator (Green) 11.2 0.441 PRESSURE / FLOW SENSORS PARTICULAR USE SENSORS Beamreceiving part 22 0.866 Beamemitting part Center of sensing 2 0.079 2.8 0.110 HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS 31 25.4 1.220 1.000 22 0.866 Center of sensing ø3.7 ø0.146 cable, 2 m 6.562 ft long 4-core × 0.2mm2 insulator diameter: ø1.2 ø0.047 Beamreceiving part ø9.4 0.370 RF-220 0.9 0.035 31 25.4 35.5 42.5 1.398 1.220 1.000 1.673 Beamemitting part M8 connector 2-M3 × 0.5 0.020 thru-hole threads RF-210 Reflector (Optional) Reflector (Optional) 33.3 1.311 12.8 0.504 35.3 1.390 M3 nut mounting holes (for mounting at the back) Reflector 49.3 59.3 1.941 2.335 2-ø3.6 ø0.142 mounting holes 25 0.984 8.3 0.327 2-ø4.6 ø0.181 mounting holes 3.2 0.126 4 0.157 3.3 0.130 40 1.575 Material: Acrylic (Reflector) ABS (Base) 21 ( 0.827 ) 8 0.315 5 0.197 MACHINE VISION SYSTEMS 11 0.433 34.3 42.31.350 1.665 30 (1.181 ) 10 0.394 8.2 0.323 4 0.157 Operation mode switch 20 0.787 3 0.118 2 2.8 0.079 0.110 50.3 1.980 FA COMPONENTS UV CURING SYSTEMS Distance adjuster (5-turn) 0.9 0.035 LASER MARKERS PLC 12.5 0.492 Operation indicator (Orange) 11.2 0.441 RF-230 Reflector (Accessory for the retroreflective type sensor) STATIC CONTROL DEVICES Sensor Stability indicator (Green) SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS 8.2 0.323 4 0.157 Operation mode switch 20 0.787 3 0.118 2-M3 × 0.5 0.020 thru-hole threads SENSOR OPTIONS WIRE-SAVING SYSTEMS CX-44□-Z Sensor PHOTOELECTRIC SENSORS INDUCTIVE PROXIMITY SENSORS The CAD data can be downloaded from our website. 3.3 0.130 Base 2-ø3.4 ø0.134 thru-holes (for mounting at the side) 25 0.984 10 0.394 2-ø3.4 ø0.134 holes, 6 0.236 deep (for mounting at the back) 8.3 0.327 2-M3 nut mounting holes (for mounting at the side) Material: A  crylic (Reflector) ABS (Base) Material: Acrylic (Reflector) ABS (Base) Two M3 (length 8 mm 0.315 in) screws with washers and two nuts are attached. Note: It is not attached with the basic type sensor. Selection Guide Amplifier Built-in Power Supply Built-in RF-11 Amplifierseparated EX-Z CX-400 30 1.181 28 1.102 ( ) RF-12 Reflective tape (Optional) 30 1.181 28 1.102 0.7 0.028 ( ) 0.7 0.028 Adhesive tape ( ) 23 25 0.984 0.906 EX-30 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 0.5 0.020 Reflective surface (Acrylic) EX-20 EX-40 30 1.181 Reflective tape (Optional) Rear surface Effective reflecting surface Material: Acrylic RF-13 30 1.181 ( ) 8 6 0.315 0.236 CY-100 EX-10 Reflective tape (Optional) Effective reflecting surface Material: Flexible polyvinyl chloride Adhesive tape ( pressure-sensitive ) adhesive Compact Photoelectric Sensor DIMENSIONS (Unit: mm in) CX-400 SERIES Ver.2 The CAD data can be downloaded from our website. MS-CX2-1 Sensor mounting bracket (Optional) 5 0.197 3.4 0.134 14 0.551 Assembly dimensions 12 0.472 3 0.118 R12 R0.472 8 0.315 22 0.866 15 0.591 7° t 1.2 t 0.047 0.5 0.020 Mounting drawing with the receiver of CX-41□ 3.4 0.134 3.4 0.134 2-ø3.4 ø0.134 holes (for RF-210) R12 R0.472 12 0.472 3 0.118 5 0.197 22 0.866 10 0.394 0.3 (0.012 ) 7˚ 25.4 1.000 31 1.220 25 0.984 Material: Stainless steel (SUS304) 9.5 0.374 Two M3 (length 12 mm 0.472 in) screws with washers are attached. 42.5 1.673 t 1.2 t 0.047 12.3 0.484 Sensor mounting bracket (Optional) 15.8 0.622 7 0.276 7.8 0.307 22 0.866 14 0.551 R12 R0.472 14° 12 0.472 3.6 (0.142 ) 15.8 0.622 8.2 0.323 4 0.157 36 1.417 55 2.165 28 1.102 4.5 0.177 5 0.197 14˚ 4.5 0.177 4 0.157 4.5 0.177 t2 t 0.079 4 0.157 R12 R0.472 12 0.472 4.5 0.177 FA COMPONENTS 15.5 0.610 MACHINE VISION SYSTEMS 7 0.276 4.5 0.177 5 0.197 8.2 0.323 18 0.709 0.9 0.035 46 1.811 13 0.512 Power Supply Built-in Amplifierseparated CY-100 EX-10 EX-20 0.9 0.035 6.2 0.244 t 2.5 t 0.098 Two M3 (length 14 mm 0.551 in) screws with washers are attached. Material: Stainless steel (SUS304) Selection Guide CX-400 29 1.142 40°20° 5.5 0.217 5.5 0.217 25 0.984 UV CURING SYSTEMS EX-Z R9.5 R0.374 EX-30 18 0.709 13 0.512 11.2 0.441 EX-40 CX-440 EQ-30 EQ-500 25.4 1.000 12.3 0.484 Beam axis 46 1.811 25 0.984 t 2.5 t 0.098 SENSOR ø25 ø0.984 R25 R0.984 19 29 0.748 1.142 4 0.157 3.4 0.134 ø55 ø2.165 ø39 ø1.535 7 0.276 Mounting drawing with the receiver of CX-41□ SENSOR 25 0.984 SENSOR 25 0.984 25.4 1.000 Assembly dimensions SENSOR 3.4 0.134 HUMAN MACHINE INTERFACES Sensor mounting bracket (Optional) 7° MEASUREMENT SENSORS Amplifier Built-in ø55 ø2.165 ø39 ø1.535 6 0.236 14° SIMPLE WIRE-SAVING UNITS ENERGY MANAGEMENT SOLUTIONS Beam axis 23 15.5 0.906 0.610 MS-CX2-4 19 0.748 SENSOR OPTIONS PLC 22 0.866 14 0.551 Two M3 (length 12 mm 0.472 in) screws with washers are attached. 7 0.276 INDUCTIVE PROXIMITY SENSORS LASER MARKERS Material: Stainless steel (SUS304) 20° PRESSURE / FLOW SENSORS Mounting drawing with the receiver of CX-41□ 7.8 0.307 40° SAFETY LIGHT CURTAINS / SAFETY COMPONENTS STATIC CONTROL DEVICES 8-ø3.4 ø0.134 holes 7 0.276 4.5 0.177 t2 t 0.079 AREA SENSORS Assembly dimensions 25 10 0.394 0.984 55 2.165 MICRO PHOTOELECTRIC SENSORS WIRE-SAVING SYSTEMS MS-CX2-2 14 0.551 LASER SENSORS PARTICULAR USE SENSORS Beam axis 20 0.787 12.5 0.492 36 1.417 3.4 0.134 13.6 0.535 25.2 0.992 14˚ FIBER SENSORS PHOTOELECTRIC SENSORS 20 0.787 14° 3.4 25 0.134 R25 42.5 0.984 R0.984 1.673 270 MQ-W RX-LS200 RX RT-610 271 FIBER SENSORS LASER SENSORS Compact Photoelectric Sensor CX-400 SERIES Ver.2 DIMENSIONS (Unit: mm in) MS-CX2-5 Sensor mounting bracket (Optional) PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS 15 0.591 AREA SENSORS t 1.5 t 0.059 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS 3.4 0.134 3.4 0.134 3.5 0.138 SENSOR OPTIONS 5 0.197 SIMPLE WIRE-SAVING UNITS STATIC CONTROL DEVICES 8 0.315 Amplifierseparated EX-Z CX-400 CY-100 EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 20 0.787 37 1.457 5 0.197 7.9 0.311 MS-CX-3 Sensor mounting bracket (Optional) Assembly dimensions t 1.2 t 0.047 30 1.181 20.5 0.807 10° R25 R0.984 3.5 0.138 5 3.4 0.197 0.134 3.4 0.134 14 0.551 8 3.4 0.315 0.134 6 0.236 35 25 0.984 1.378 25.2 0.992 13.6 0.535 11.2 0.441 18 0.709 Beam axis R25 R0.984 10° 15 0.591 3.4 0.134 5 0.197 6 0.236 0.5 0.020 Mounting drawing with the receiver of CX-41□ 8.5 0.335 Two M3 (length 12 mm 0.472 in) screws with washers are attached. Power Supply Built-in 7 0.276 20 7 0.787 0.276 37 1.457 Material: Stainless steel (SUS304) Amplifier Built-in R25 R0.984 45 1.772 Two M3 (length 12 mm 0.472 in) screws with washers are attached. MACHINE VISION SYSTEMS Selection Guide 7° Beam axis Material: Stainless steel (SUS304) FA COMPONENTS UV CURING SYSTEMS 25.4 1.000 18.9 0.744 5 0.197 6.5 0.256 PLC ENERGY MANAGEMENT SOLUTIONS t 1.5 t 0.059 7.9 0.311 LASER MARKERS HUMAN MACHINE INTERFACES 15 0.591 20.6 26.2 0.811 1.031 18.9 0.744 5 0.197 6.5 0.256 PARTICULAR USE SENSORS MEASUREMENT SENSORS Mounting drawing with the receiver of CX-41□ R19 R 0.748 R25 R0.984 45 1.772 INDUCTIVE PROXIMITY SENSORS Assembly dimensions 25 0.984 19 0.748 19 0.748 7° PRESSURE / FLOW SENSORS WIRE-SAVING SYSTEMS The CAD data can be downloaded from our website. 6 0.236 3.5 0.138 4.8 0.189 18 0.709 6 0.236 3.4 0.134 8 0.315 14 0.551 30 1.181 10° t 1.2 t 0.047 0.4 0.016 ( 8.5 0.335 9 0.354 31 1.220 20 0.787 25.4 1.000 35 1.378 ) Compact Photoelectric Sensor DIMENSIONS (Unit: mm in) CX-400 SERIES Ver.2 The CAD data can be downloaded from our website. MS-RF21-1 Reflector mounting bracket for RF-210 (Optional) 23 0.906 5.5 0.217 23 0.906 ø36 50 ø1.417 1.969 30° 10 0.394 3.2 0.126 ø25 t 1.2 ø0.984 t 0.047 12.5 0.492 10 0.394 R7.5 R0.295 46 1.811 25 0.984 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS 20° PARTICULAR USE SENSORS 46 1.811 SENSOR OPTIONS 25 0.984 13 0.512 SIMPLE WIRE-SAVING UNITS 13 0.512 WIRE-SAVING SYSTEMS Material: Stainless steel (SUS304) Two M3 (length 12 mm 0.472 in) screws with washers are attached. MS-RF22 Reflector mounting bracket for RF-220 (Optional) Assembly dimensions 25 0.984 4.5 0.177 35 1.378 25 0.984 28.3 19.3 1.114 0.760 4 0.157 35.3 1.390 HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS 8.3 0.327 FA COMPONENTS 16 0.630 8 0.315 6 0.236 8-M3 × 0.5 0.020 thru-hole threads 44.3 1.744 t 1.6 t 0.063 MACHINE VISION SYSTEMS 34.3 1.350 21 ( 0.827 ) 27 (1.063 ) 20 0.787 STATIC CONTROL DEVICES PLC 10 0.394 11 0.433 10 0.394 MEASUREMENT SENSORS LASER MARKERS 25 0.984 4.5 0.177 44 10 0.394 1.732 AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS 30° 3.5 0.138 LASER SENSORS MICRO PHOTOELECTRIC SENSORS ø36 50 ø1.417 1.969 20° 16 0.630 FIBER SENSORS PHOTOELECTRIC SENSORS Assembly dimensions 5.5 0.217 272 8 0.315 t 1.6 t 0.063 UV CURING SYSTEMS 4 0.157 6 0.236 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Selection Guide Two M3 (length 8 mm 0.315 in) screws with washers are attached. Amplifier Built-in MS-RF23 Reflector mounting bracket for RF-230 (Optional) 40 1.575 ( ) 3 0.118 Amplifierseparated Assembly dimensions 4.5 0.177 4.5 0.177 10 0.394 11 0.433 40 1.575 28.3 19.3 1.114 0.760 50.3 1.980 5 0.197 EX-Z CX-400 10 0.394 50 1.969 40 1.575 CY-100 EX-10 8.3 0.327 EX-20 EX-30 16 0.630 18 0.709 12 0.472 3 (0.118 ) EX-40 15 0.591 61 2.402 35 1.378 t2 t 0.079 7 0.276 26 1.024 28 1.102 ( ) 20 0.787 8-M4 × 0.7 0.028 thru-hole threads Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Two M4 (length 10 mm 0.394 in) screws with washers are attached. Power Supply Built-in ( 30 (1.181 ) ) 7 0.276 CX-440 49.3 1.941 61.3 2.413 37 1.457 10 0.394 40 1.575 5 0.197 EQ-30 t2 t 0.079 EQ-500 MQ-W RX-LS200 RX RT-610
FX-301
1. 物料型号:文档中提到了多个型号,例如CX-411, CX-412, CX-413, CX-491, CX-493, CX-481, CX-482, CX-424, CX-421, CX-422, CX-423, CX-441, CX-443, CX-444, CX-442等。

2. 器件简介:文档介绍了CX-400系列的紧凑型光电传感器,它们具有内置放大器、环境友好、低功耗等特点,适用于多种工业应用。

3. 引脚分配:文档中提供了不同型号传感器的引脚分配图和说明,例如NPN和PNP输出类型的I/O电路图。

4. 参数特性:文档列出了传感器的各种参数特性,包括感应范围、电源电压、电流消耗、输出类型、响应时间、环境温度和湿度等。

5. 功能详解:文档详细解释了传感器的功能,如自动背景抑制功能(BGS/FGS)、抗干扰能力、极性保护、感应模式选择输入等。

6. 应用信息:文档提供了传感器的应用示例,如检测不到位的胶带送料盒、在多尘环境中检测物体、检测透明玻璃瓶、检测小型药片等。

7. 封装信息:文档包含了传感器的尺寸图和安装支架的详细信息,以及可选配件如反光带、传感器安装支架等。
FX-301 价格&库存

很抱歉,暂时无法提供与“FX-301”相匹配的价格&库存,您可以联系我们找货

免费人工找货
FX-301
  •  国内价格
  • 1+1162.92360

库存:41