Compact Photoelectric Sensor
245
Amplifier Built-in
CX-400 SERIES Ver.2
FIBER
SENSORS
Related Information
LASER
SENSORS
General terms and conditions.............. F-3
Selection guide............................... P.231~
MS-AJ / CHX-SC2...............P.953 / P.959
Glossary of terms......................... P.1549~
General precautions..................... P.1552~
Korea’s S-mark.............................. P.1602
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Recognition
AREA
SENSORS
Certified
(Some models only)
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
panasonic.net/id/pidsx/global
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
PNP output
type available
Light intensity
monitor
Interference
prevention
Sensors that are environmentally and user friendly.
Reducing environmental burdens further
Up to 60% less power consumption
The various lineup covers through the inclusion of a newly developed
custom integrated circuit.The CX-400 series achieves reductions in
power consumption of up to 60%, averaging 44% reduction when
upgrading due to its unique design. These sensors reduce carbon
emissions and contribute to environmental friendliness.
Providing stable detection with low power
consumption
Includes an analog CMOS
processor ASIC
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
EX-Z
Upgrade for up to
60
CX-400
CY-100
% reduction
EX-10
Strong against oil and coolant liquids CX-41□/42□/49□
The lens material for
the thru-beam type,
retroreflective type
(excluding the CX-48□)
and the diffuse reflective
type are made of a strong
acrylic that resists the
harmful effects of coolants.
These sensors can be
used with confidence even
around metal processing
machinery that disperses oil
mists. The protection mechanism also conforms to IP67
(IEC).
Test Oil
JIS Standard
Product Name
Lubricant
-
Velocity Oil No. 3
Water-insoluble
cutting oil
2-5
Daphnecut AS-30D
2-11
Yushiron Oil No.2ac (Note)
W1-1
Yushiron Lubic HWC68 (Note)
W2-1
Yushiroken S50N (Note)
Water-soluble
cutting oil
1,000 hours; Immersion (depth 0 m); Insulation resistance 20 MΩ/250 V
Note: Yushiron and Yushiroken are registered trademarks of
Yushiro Chemical Industry Co., Ltd.
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
Previous CX-482
25 mA
Strong against ethanol
New CX-482
10 mA
Contributing to reduced carbon dioxide emissions
Electricity consumed by the CX-400
series has been reduced on average
10.5 mA. Calculating 8 hours/day, 260
days (operating 5 days/week) for a total
of 2,080 hours/year leads to:
The CX-400
contributes
Approx. 84.6 t annually in carbon
dioxide reductions to the world
CX-44□/48□
A strong, ethanol resistant
polycarbonate was used for the
front and display covers.
Safe even for installing near
food processing machinery that
disperses ethanol based detergents.
The protection mechanism also
conforms to IP67 (IEC).
Caution: Set the CX-48□ so that cleaning liquid will not get on to the
attached reflector.
Compact Photoelectric Sensor
CX-400 SERIES Ver.2
APPLICATIONS
246
FIBER
SENSORS
Detecting out of position tape
feeder cassette
Detecting objects in dusty
environment
Passage confirmation of object
on a conveyor belt
LASER
SENSORS
PHOTOELECTRIC
SENSORS
CX-412
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Slit mask
CX-491
Out of position
CX-411
Detecting transparent glass bottles
Detecting a small tablet
Detecting a biscuit
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
CX-441
CX-443
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
CX-481
LASER
MARKERS
PLC
BASIC PERFORMANCE
Strong infrared beam
CX-412/413
Remarkable penetrating power enables applications
such as package content detection.
Can sense differences as small as 0.4 mm 0.016 in,
CX-441/443
with hysteresis of 2 % or less
An advanced optical system provides sensing
performance that is 2.5 times approx. than conventional
models. Even ultra-small differences of 0.4 mm 0.016 in
can be detected accurately.
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
2.5 times the
sensing capability!
Note: When sensing utilizing penetrating power, make sure to verify
using the actual sensor.
Hardly affected by colors
CX-441/443
Both black and white objects can be sensed at the
same distances. No adjuster control is needed, even
when products of different colors are moving along the
production line.
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
Height differences of as
little as 0.4 mm 0.016 in
can be detected at a
setting distance of 20 mm
0.787 in
Retroreflective type with polarizing filters CX-491
Built-in polarizing filters ensure stable sensing even on a
specular object.
EX-Z
CX-400
CY-100
EX-10
EX-20
EX-30
30 % higher
sensing capability
EX-40
CX-440
EQ-30
EQ-500
MQ-W
CX-491
The difference in sensing ranges is 1% or less between non-glossy white paper with a
setting distance of 50 mm 1.969 in and non-glossy gray paper with a brightness level of 5.
RX-LS200
RX
RT-610
247
Compact Photoelectric Sensor
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
CX-400 SERIES Ver.2
BASIC PERFORMANCE
Our unique optical system and transparent object
sensing circuitry provide stable sensing of even thinner
transparent objects than the conventional models.
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Twice the
sensing range!
PARTICULAR
USE SENSORS
CX-482
SIMPLE
WIRE-SAVING
UNITS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
Long sensing range of 5 m 16.4 ft
Transparent objects detectable with CX-48□ (Typical examples)
Sensing object
Sensing object size (mm in)
Glass sheet
50 × 50 1.969 × 1.969 t = 0.7 0.028
Cylindrical glass
ø50 ø1.969 ℓ = 50 1.969 t = 1.3 0.051
Acrylic board
50 × 50 1.969 × 1.969 t = 1.0 0.039
Styrol (Floppy case)
50 × 50 1.969 × 1.969 t = 0.9 0.035
Food wrapping film
50 × 50 1.969 × 1.969 t = 10 µm 0.394 mil
Cigarette case film
50 × 50 1.969 × 1.969 t = 20 µm 0.787 mil
Vinyl sack
50 × 50 1.969 × 1.969 t = 30 µm 1.181 mil
PET bottle (500mℓ)
ø66 ø2.598
Reflector setting range CX-481: 300 to 500 mm 11.811 to 19.685 in,
CX-482: 1 to 2 m 3.281 to 6.562 ft
[with the RF-230 reflector at the optimum condition (Note)]
Each object should pass across the beam at the center between
the sensor and the reflector.
ℓ: Length of cylindrical glasses
t: Thickness of sensing object
Note: The optimum condition is defined as the condition in which the
sensitivity level is set such that the stability indicator just lights
up when the object is absent.
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
CX-48□
Introducing the transparent object sensing type sensor
CX-493
Ultra-long sensing range of 30 m 98.4 ft CX-413
The CX-413 achieves the
ultra-long sensing range
of 30 m 98.4 ft. It can be
used for a stacker crane
or a multilevel parking
structure.
A long 5 m 16.4 ft
sensing range is
possible with the red
LED type that is easy
to align with the beam
axis. Can be used for
wide automatic door
shutters.
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
EX-Z
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
ENVIRONMENTAL RESISTANCE
Strong on dust and dirt
CX-412/413
Because the
light source is an
infrared light, it is
strong on dust and
dirt compared to
the red beam type.
Strong even in cold environments
Stronger noise resistance
The CX-400 series has
a higher noise resistance
than its previons model. By
incorporating an inverter
countermeasure circuit that
appropriately shifts with peak
wavelength, the sensor now
resists high-frequency noise
from high-voltage inverter
motors and
inverter lights more effectively.
Fluorescent
light
Stable performance can be maintained even in
environments of –25 °C –13 °F.
ECO
Thoroughly eliminating unnecessary waste, Reducing many environmental burdens
The CX-400 series has three different cable length
types and uses very simple packaging to reduce
waste. The bag is made of polyethylene and does not
emit toxic gasses.
Inverter motor
Compact Photoelectric Sensor
CX-400 SERIES Ver.2
MOUNTING
Beam axis alignment made easy with a high luminance spot beam CX-423
The bright spot makes beam axis alignment easy CX-44□
These sensors have a
high luminance red LED
spot beam which provides
bright visibility enabling
the sensing position to be
checked at a glance.
Because it achieved small
beam spot approx. ø2 mm
ø0.079 in at setting distance
100 mm 3.937 in, approx.
ø5 mm ø0.197 in at setting
distance 200 mm 7.874 in,
even the minutest object
can be accurately detected.
These sensors have
a high luminance red
spot that provides
bright visibility. The
sensing position can be
checked at a glance.
Because the CX-441
sensor has the smallest
spot in its class ø2 mm
ø0.079 in approx., even
the minutest object can
be accurately detected.
CX-423
Great visibility approx. ø2 mm
ø0.079 in high luminance spot beam
(at setting distance 100 mm 3.937 in)
248
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Great visibility
approx. ø2 mm
ø0.079 in high
luminance spot
CX-441
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
OPERABILITY
Reduction of volume adjustment labor CX-42□
Can be used for sensing minute differences CX-44□
Because these sensors possess many variations
depending on the sensing range, enables you to make
optimal volume adjustment easily.
Equipped with a 5-turn adjuster so that even challenging
range settings can be handled with ease.
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
CX-422: 800 mm 31.496 in
CX-421: 300 mm 11.811 in
CX-424: 100 mm 3.937 in
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
Narrow-view type
ENERGY
MANAGEMENT
SOLUTIONS
CX-423: 70 to 300 mm
2.756 to 11.811 in
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
VARIETIES
Basic type available
Select from 2 spot diameters as per the application CX-441/443
Omit the sensitivity adjuster and operation mode switch and
release a basic type cable 0.5 m 1.641 ft in length. If the
usage is clear, quick construction can be performed onsite
without detailed adjustments and the cost can be controlled.
Within the choice of 50 mm 1.969 in sensing range sensors,
we offer small spot approx. ø2 mm ø0.079 in type optimal
for detecting minute object and large approx. ø6.5 mm
ø0.256 in spot type capable of sensing object covered with
holes and grooves.
Less processing time
M8 plug-in connector type and M12 pigtailed type are
available. This contributes to less time spent in setting
up. In addition, cable types are available with cable
lengths of 0.5 m 1.640 ft, 2 m 6.562 ft and 5 m 16.404 ft.
This results in less wastage.
EX-Z
CX-400
CY-100
EX-10
EX-20
No unnecessary cables or terminal blocks
CX-441
Cable type
5 m 16.404 ft
Great maintainability
2 m 6.562 ft
M8 plug-in
connector
type
ft /
( 25 mm 6.562
16.404 ft )
ft /
( 25 mm 6.562
16.404 ft )
Elbow
Straight
0.5 m
1.640 ft
M12 pigtailed
type
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
Straight
Spot diameter: ø2 mm
ø0.079 in
approx.
[Positioning]
Detects minute holes.
CX-443
Spot diameter: ø6.5 mm
ø0.256 in
approx.
Detection of presence /
absence of objects
Ignores minute holes and
accurately detects objects.
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
ft /
( 25 mm 6.562
16.404 ft )
249
Compact Photoelectric Sensor
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
CX-400 SERIES Ver.2
FUNCTIONS
CX-44□
BGS/FGS functions make even the most challenging settings possible!
For details on the operation of the BGS/FGS functions, refer to “BGS/FGS functions (p.267)” of “PRECAUTIONS
FOR PROPER USE”.
The BGS function is best suited for the following case
The FGS function is best suited for the following case
Background not present
When object and background are separated
Background present
When object and background are close together
When the object is glossy or uneven
BGS
FGS
Unaffected by gloss, color or
uneven surfaces when sensing
objects present on a conveyor belt.
Not affected if the background
color changes or someone
passes behind the conveyor.
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
Caution: Please use the FGS function together with a conveyor or other
background unit.
BGS (Background suppression) function
The sensor judges that an object is present when light
is received at position A of the light-receiving element
(2-segment element).
This is useful if the object and background are far
apart. The distance adjustment method is the same as
the conventional adjustment method for adjustable
range reflective type sensors.
MACHINE VISION
SYSTEMS
OFF
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
Background
UV CURING
SYSTEMS
Light received at
element B, or
light not received
Element A
Object
EX-20
EX-30
EX-40
CX-440
EQ-30
MQ-W
RX
RT-610
OFF
A
Object present
For glossy object
ON
ON
Emitting
element
B
Lens
Setting
distance
Conveyor
Light received
at position B
A conveyor or
other
back-ground
must be present
Strong against interference
The interference prevention function lets two sensors to
be mounted close together precisely.
Interference
prevention
filter (Optional)
Retroreflective type
Diffuse reflective type
Adjustable range reflective type
EQ-500
RX-LS200
Object absent
ON in all other conditions
Setting distance
CX-400
EX-10
OFF in this condition only
ON
EX-Z
CY-100
The sensor judges that an object is present when no
light is received at position B of the light-receiving
element (2- segment element). Accordingly, even
objects that are glossy can be sensed. This is useful if
the object and background are close together, or if the
object being sensed is glossy.
(Light received at element A)
Element B
Moving object
in the back
FGS (Foreground suppression) function
Thru-beam type
Only CX-411
Automatic
interference
prevention function
Conveyor
Light received
at position A
Conveyor
Light is not
received at
position B, so a
object is judged
to be present
Compact Photoelectric Sensor
CX-400 SERIES Ver.2
ORDER GUIDE
FIBER
SENSORS
LASER
SENSORS
Standard type
Type
Appearance
Model No. (Note 1)
Sensing range
CX-411-P
CX-412
CX-412-P
CX-413
CX-413-P
CX-491
CX-491-P
CX-493
CX-493-P
50 to 500 mm 1.969 to 19.685 in (Note 2)
CX-481
CX-481-P
50 to 1,000mm 1.969 to 39.37 in (Note 2)
CX-483
CX-483-P
0.1 to 2 m 0.328 to 6.562 ft (Note 2)
CX-482
CX-482-P
MEASUREMENT
SENSORS
CX-424
CX-424-P
STATIC
CONTROL
DEVICES
CX-421
CX-421-P
CX-422
CX-422-P
CX-423
CX-423-P
CX-441
CX-441-P
CX-443
CX-443-P
CX-444
CX-444-P
CX-442
CX-442-P
Thru-beam
Long sensing
range
30 m 98.425 ft
Long sensing With polarizing
range
filters
PHOTOELECTRIC
SENSORS
CX-411
15 m 49.213 ft
3 m 9.843 ft (Note 2)
Red LED
300 mm 11.811 in
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Infrared
LED
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Red LED
5 m 16.404 ft (Note 2)
For transparent
object sensing
Retroreflective
Emitting
element
PNP output
100 mm 3.937 in
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Switchable
either Light-ON
or Dark-ON
Infrared
LED
Infrared
LED
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
LASER
MARKERS
PLC
800 mm 31.496 in
Small Narrowspot view
Diffuse reflective
Output
operation
NPN output
10 m 32.808 ft
Adjustable range reflective
250
70 to 300 mm 2.756 to 11.811 in
HUMAN
MACHINE
INTERFACES
Red LED
FA
COMPONENTS
2 to 50 mm 0.079 to 1.969 in
15 to 100 mm 0.591 to 3.937 in
20 to 300 mm 0.787 to 11.811 in
Switchable either
Detection-ON or
Detection-OFF
MACHINE
VISION
SYSTEMS
Red LED
NOTE: Mounting bracket is not supplied with the sensor. Please select from the range of optional sensor mounting brackets.
Notes: 1) The model No. with “E” shown on the label affixed to the thru-beam type sensor is the emitter, “D” shown on the label is the receiver.
2) The sensing range of the retroreflective type sensor is specified for the RF-230 (optional) reflector. The sensing range represents the actual sensing
range of the sensor. The sensing ranges itemized in “A” of the table below may vary depending on the shape of sensing object. Be sure to check the
operation with the actual sensing object.
Sensing
range: A
Sensor
CX-491□
CX-493□
CX-483□
CX-482□
50 to 500 mm
50 to 1,000 mm 0.1 to 2 m
1.969 to 19.685 in 1.969 to 39.37 in 0.328 to 6.562 ft
Sensing
object
A
0 to 3 m
0 to 9.843 ft
Setting range
of the reflector: B
B
0.1 to 3 m
0.1 to 5 m
100 to 500 mm 100 to 1,000 mm 0.8 to 2 m
0.328 to 9.843 ft 0.328 to 16.404 ft 3.937 to 19.685 in 3.937 to 39.37 in 2.625 to 6.562 ft
Reflector
0 to 5 m
0 to 16.404 ft
CX-481□
ENERGY
MANAGEMENT
SOLUTIONS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
EX-Z
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
251
Compact Photoelectric Sensor
ORDER GUIDE
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
CX-400 SERIES Ver.2
Basic type (Without operation mode switch and sensitivity adjuster. Cable is 0.5 m 1.640 ft long.)
Type
Appearance
Sensing range
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
Thru-beam
Retroreflective
INDUCTIVE
PROXIMITY
SENSORS
Long sensing
range
PRESSURE /
FLOW
SENSORS
15 m 49.213 ft
3 m 9.843 ft (Note 3)
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
EX-Z
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
CX-411A-C05
CX-411A-P-C05
Light-ON
CX-411B-C05
CX-411B-P-C05
Dark-ON
CX-412A-C05
CX-412A-P-C05
Light-ON
CX-412B-C05
CX-412B-P-C05
Dark-ON
CX-491A-C05-Y CX-491A-P-C05-Y
Light-ON
CX-491B-C05-Y CX-491B-P-C05-Y
Dark-ON
Optional (Note 2)
Emitting
element
Red LED
Infrared
LED
Red LED
NOTE: Mounting bracket is not supplied with the sensor. Please select from the range of optional sensor mounting brackets.
Sensing
range: A
PLC
ENERGY
MANAGEMENT
SOLUTIONS
Output
operation
Notes: 1) The model No. with “E” shown on the label affixed to the thru-beam type sensor is the emitter, “D” shown on the label is the receiver.
2) The reflector is an option. The sensing range of the leflector is specified for the RF-230.
3) The sensing range of the retroreflective type sensor is specified for the RF-230 (optional) reflector (p.253). The sensing range represents the actual
sensing range of the sensor. The sensing range : A of the table below may vary depending on the shape of sensing object. Be sure to check the
operation with the actual sensing object.
LASER
MARKERS
HUMAN
MACHINE
INTERFACES
PNP output
10 m 32.808 ft
With polarizing
filters
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
Model No.(Note 1)
NPN output
Sensor
CX-491□
Sensing
object
A
0 to 3 m
0 to 9.843 ft
Setting range
of the reflector: B
B
0.1 to 3 m
0.328 to 9.843 ft
Reflector
(Optional)
Compact Photoelectric Sensor
CX-400 SERIES Ver.2
ORDER GUIDE
FIBER
SENSORS
LASER
SENSORS
0.5 m 1.640 ft / 5 m 16.404 ft cable length types
0.5 m 1.640 ft / 5 m 16.404 ft cable length types (standard: 2 m 6.562 ft, basic: 0.5 m 1.640 ft) are also available.
When ordering this type, suffix “-C05” for the 0.5 m 1.640 ft cable length type, “-C5” for the 5 m 16.404 ft cable length type to the model No.
(Excluding CX-44□ and basic type)
(e.g.) 0.5 m 1.640 ft cable length type of CX-411-P is “CX-411-P-C05”
5 m 16.404 ft cable length type of CX-411-P is “CX-411-P-C5”
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
M8 plug-in connector type, M12 pigtailed type
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
M8 plug-in connector type and M12 pigtailed type are also available.
When ordering this type, suffix “-Z” for the M8 connector type, “-J” for the M12 pigtailed type to the model No.
(Please note that M12 pigtailed type is not available for CX-44□. Excluding basic type)
(e.g.) M8 connector type of CX-411-P is “CX-411-P-Z”
M12 pigtailed type of CX-411-P is “CX-411-P-J”
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
• Mating cable (2 cables are required for the thru-beam type.)
For M12
pigtailed type
For M8 plug-in
connector type
Type
Straight
Elbow
2-core
4-core
252
Model No.
Cable length
CN-24A-C2
2 m 6.562 ft
CN-24A-C5
5 m 16.404 ft
CN-24AL-C2
2 m 6.562 ft
CN-24AL-C5
5 m 16.404 ft
CN-22-C2
2 m 6.562 ft
CN-22-C5
5 m 16.404 ft
CN-24-C2
2 m 6.562 ft
CN-24-C5
5 m 16.404 ft
Description
PARTICULAR
USE
SENSORS
Mating cable
• CN-24A-C2
CN-24A-C5
• CN-24AL-C2
CN-24AL-C5
SIMPLE
WIRE-SAVING
UNITS
Can be used with all models
For thru-beam type emitter
(2-core)
WIRE-SAVING
SYSTEMS
ø9 mm
ø0.354 in
31.4 mm
1.236 in
23.1 mm
0.909 in
ø9 mm
ø0.354 in
ø4 mm
ø0.157 in
Can be used with all models
ø4 mm
ø0.157 in
ø14 mm
ø0.551 in
• RF-230 (Reflector)
300 mm
11.811 in
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
• CN-22-C2, CN-22-C5
CN-24-C2, CN-24-C5
Accessory
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
20.5 mm
0.807 in
Package without reflector
NPN output type: CX-491-Y
PNP output type: CX-491-P-Y
SENSOR
OPTIONS
ENERGY
MANAGEMENT
SOLUTIONS
ø5 mm
ø0.197 in
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
EX-Z
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
253
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Compact Photoelectric Sensor
OPTIONS
Model No.
Designation
Slit mask
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
OS-CX-05
()
For thrubeam type
sensor only
WIRE-SAVING
SYSTEMS
CX-411□
OS-CX-1
CX-411□
CX-411□
OS-CX-05×6
Rectangular slit
mask
For thrubeam type
sensor only
()
CX-413□
OS-CX-1×6
CX-411□
PLC
Interference
prevention filter
For CX-411□
only
Model No.
()
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
(Vertical, Silver) 2 pcs. per set
PF-CX4-H
Reflector
()
For retroreflective type
sensor only
Selection
Guide
EX-Z
RF-230(Note 3)
CX-440
Sensor
CX-481□
CX-483□
MQ-W
RX-LS200
RX
RT-610
Setting range
of the reflector: B
Model No.
Sensor
EQ-30
EQ-500
0.5 × 6 mm
0.020 × 0.236 in
1 × 6 mm
0.039 × 0.236 in
2 × 6 mm
0.079 × 0.236 in
20 mm 0.787 in
600 mm 23.622 in
30 mm 1.181 in
Slit on one side
Slit on both sides
ø12 mm ø0.472 in
ø0.5 mm ø0.020 in
1,200 mm 47.242 in 60 mm 2.362 in
900 mm 35.433 in
100 mm 3.937 in
1.35 m 4.429 ft
150 mm 5.906 in
2.7 m 8.857 ft
300 mm 11.811 in
2 m 6.562 ft
400 mm 15.748 in
3 m 9.843 ft
600 mm 23.622 in
6 m 19.685 ft
1,200 mm 47.242 in
2 m 6.562 ft
400 mm 15.748 in
3 m 9.843 ft
600 mm 23.622 in
6 m 19.685 ft
1,200 mm 47.242 in
3 m 9.843 ft
1 m 3.281 ft
4.5 m 14.764 ft
1.5 m 4.921 ft
9 m 29.528 ft
3 m 9.843 ft
5 m 16.404 ft
2 m 6.562 ft
7.5 m 24.606 ft
3 m 9.843 ft
15 m 49.213 ft
6 m 19.685 ft
Sensing range
Min. sensing object
ø12 mm ø0.472 in
(Note 1)
5 m 16.404 ft (Note 1)
CX-491□
1 m 3.281 ft (Note 2)
CX-493□
1.5 m 4.921 ft (Note 2)
ø1 mm ø0.039 in
ø12 mm ø0.472 in
ø1.5 mm ø0.059 in
ø2 mm ø0.079 in
ø12 mm ø0.472 in
ø3 mm ø0.118 in
ø12 mm ø0.472 in
0.5 × 6 mm
0.020 × 0.236 in
ø12 mm ø0.472 in
1 × 6 mm
0.039 × 0.236 in
ø12 mm ø0.472 in
2 × 6 mm
0.079 × 0.236 in
Round slit mask
Round slit mask
(Stainless steel)
• OS-CX-□
Fitted on the front face
of the sensor with onetouch.
Rectangular slit mask
CX-481□
• OS-CX-□×6
Fitted on the front face
of the sensor with onetouch.
ø30 mm ø1.181 in
CX-483□
0.1 to 0.3 m 0.328 to 0.984 ft (Note 2)
CX-482□
0.1 to 0.6 m 0.328 to 1.969 ft (Note 2)
CX-491□
1.5 m 4.921 ft (Note 2)
CX-493□
3 m 9.843 ft (Note 2)
CX-481□
50 to 300 mm 1.969 to 11.811 in (Note 2)
CX-483□
0.1 to 0.7 m 0.328 to 2.297 ft (Note 2)
CX-482□
0.1 to 1.3 m 0.328 to 4.265 ft (Note 2)
CX-491□-Y□
3 m 9.843 ft (Note 2)
Sensing
object
EX-10
EX-40
ø2 mm
ø0.079 in
Slit on both sides
400 mm 15.748 in
ø35 mm ø1.378 in
Interference
prevention filter
Rectangular slit mask
(Stainless steel)
Interference prevention filter
• PF-CX4-V
(Vertical, Silver)
• PF-CX4-H
(Horizontal, Light brown)
Two sets of CX-411□
can be mounted close
together.
ø50 mm ø1.969 in
Sensing
range: A
CY-100
EX-30
ø1 mm
ø0.039 in
Slit on one side
Min. sensing object
Notes: 1) Value when attached on both sides.
2) Set the distance between the CX-491□/493□ and the reflector to 0.1 m 0.328 ft or more.
However, see the table below for CX-48□.
The sensing range “A” may vary depending on the shape of sensing object.
Be sure to check the operation with the actual sensing object.
CX-400
EX-20
ø0.5 mm
ø0.020 in
Sensing range
(Horizontal, Light brown) 2 pcs. per set
RF-210
Amplifier
Built-in
Slit size
PF-CX4-V
RF-220
Amplifierseparated
CX-412□
CX-413□
Designation
Power Supply
Built-in
CX-412□
CX-413□
OS-CX-2×6
LASER
MARKERS
UV
CURING
SYSTEMS
CX-412□
CX-411□
STATIC
CONTROL
DEVICES
MACHINE
VISION
SYSTEMS
CX-412□
CX-413□
MEASUREMENT
SENSORS
HUMAN
MACHINE
INTERFACES
CX-412□
CX-413□
OS-CX-2
PARTICULAR
USE
SENSORS
SIMPLE
WIRE-SAVING
UNITS
CX-412□
CX-413□
Round slit mask
INDUCTIVE
PROXIMITY
SENSORS
SENSOR
OPTIONS
Sensor
CX-411□
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
CX-400 SERIES Ver.2
CX-482□
Reflector
Reflector
• RF-210
Reflector
A
B
RF-220
50 to 300 mm 1.969 to 11.811 in 100 to 300 mm 3.937 to 11.811 in
RF-220
0.1 to 0.7 m 0.328 to 2.297 ft 0.2 to 0.7 m 0.656 to 2.297 ft
RF-210
0.1 to 0.3 m 0.328 to 0.984 ft 0.1 to 0.3 m 0.328 to 0.984 ft
RF-230
0.05 to 1 m 0.164 to 3.281 ft 0.1 to 1 m 0.328 to 3.281 ft
RF-220
0.1 to 1.3 m 0.328 to 4.265 ft 0.5 to 1.3 m 1.640 to 4.265 ft
RF-210
0.1 to 0.6 m 0.328 to 1.969 ft 0.3 to 0.6 m 0.984 to 1.969 ft
12.8 mm
0.504 in
33.3 mm
1.311 in
3)
RF-230 is attached to the retroreflective type sensor other than the basic type.
11 mm
0.433 in
• RF-220
35.3 mm
1.390 in
8.3 mm
0.327 in
• RF-230
50.3 mm
1.98 in
42.3 mm
1.665 in
59.3 mm
2.235 in
8.3 mm
0.327 in
Compact Photoelectric Sensor
CX-400 SERIES Ver.2
254
OPTIONS
Designation
FIBER
SENSORS
Model No.
MS-RF21-1
Reflector
mounting
bracket
• Sensing range (Note 4):
0.7 m 2.297 ft [CX-491□]
1.2 m 3.937 ft [CX-493□]
0.1 to 0.6 m
0.328 to 1.969 ft [CX-482□]
RF-12
• Sensing range (Note 5):
RF-13
0.5 m 1.640 ft [CX-491□]
AREA
SENSORS
• Ambient temperature: –25 to +50 °C
–13 to +122 °F
• Ambient humidity: 35 to 85 % RH
Notes: 1) K
eep the tape free from
stress. If it is pressed too
much, its capability may
deteriorate.
2) Do not cut the tape. It will
deteriorate the sensing
performance.
• Ambient temperature: –25 to +55 °C
–13 to +131 °F
• Ambient humidity: 35 to 85 % RH
Foot angled mounting bracket
It can also be used for mounting RF-210.
MS-CX2-1
Sensor checker
(Note 3)
MS-CX2-4
MS-CX2-5
Back biangled mounting bracket
MS-CX-3
Back angled mounting bracket
MS-AJ1
Horizontal mounting type
MS-AJ2
Vertical mounting type
MS-AJ1-A
Horizontal mounting type
MS-AJ2-A
Vertical mounting type
MS-AJ1-M
Horizontal mounting type
MS-AJ2-M
Vertical mounting type
CHX-SC2
It is useful for beam alignment of thru-beam type sensors. The optimum
receiver position is given by indicators, as well as an audio signal.
Basic assembly
45˚
Assembly for reflector
• MS-AJ1-A
45˚
Elevation
angle: ±45˚
Height
adjustment:
150 mm
5.906 in
approx.
Mounting hole
for M6 screw
• MS-AJ2
45˚
45˚
Elevation
angle: ±45˚
With the lateral arm, the
sensor can sense from
above a production line.
Height
adjustment:
150 mm
5.906 in
approx.
Mounting hole
for M6 screw
Swivel:
360˚ rotation
Forward / back
adjustment:
130 mm 5.118 in
approx.
Height
adjustment:
150 mm
5.906 in
approx.
45˚
Elevation
angle: ±45˚
360˚
rotation
45˚
45˚
Angle adjustment: ±45˚
With the lateral arm, the
sensor can sense from
above a production line.
Forward / back
adjustment:
130 mm 5.118 in
approx.
360˚
rotation
SENSOR
OPTIONS
Reflective tape
30 mm
1.181 in
SIMPLE
WIRE-SAVING
UNITS
• RF-12
0.7 mm
0.028 in
8 mm
0.315 in
30 mm
1.181 in
0.7 mm
0.028 in
25 mm
0.984 in
STATIC
CONTROL
DEVICES
0.5 mm
0.020 in
30 mm
1.181 in
LASER
MARKERS
PLC
30 mm
1.181 in
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
Sensor mounting bracket
• MS-CX2-1
• MS-CX2-2
45˚
45˚
Mounting
Angle adjustment: ±45˚ hole for
M6 screw
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Two M3 (length 12 mm
0.472 in) screws with
washers are attached.
Two M3 (length 12 mm
0.472 in) screws with
washers are attached.
• MS-CX2-4
• MS-CX2-5
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Height
adjustment:
150 mm
5.906 in
approx.
Amplifierseparated
Two M3 (length 14 mm
0.551 in) screws with
washers are attached.
Two M3 (length 12 mm
0.472 in) screws with
washers are attached.
• MS-CX-3
EX-Z
CX-400
CY-100
EX-10
EX-20
EX-30
• MS-AJ2-M
Swivel:
360˚ rotation
Height
adjustment:
150 mm
5.906 in
approx.
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Mounting hole
for M6 screw
Mounting
hole for
M6 screw
PRESSURE /
FLOW
SENSORS
PARTICULAR
USE
SENSORS
Two M4 (length 10 mm
0.394 in) screws with
washers are attached.
Swivel:
360˚ rotation
45˚
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
INDUCTIVE
PROXIMITY
SENSORS
• MS-AJ1-M
• MS-AJ2-A
Swivel:
360˚ rotation
• MS-RF23
Lateral arm assembly
Universal sensor mounting stand
Two M3 (length 8 mm
0.315 in) screws with
washers are attached.
• RF-13
Notes: 1) The plug-in connector type sensor does not allow use of some sensor mounting brackets
because of the protrusion of the connector.
2) Refer to p.953~ for the universal sensor mounting stand MS-AJ series.
3) Refer to p.959~ for the sensor checker CHX-SC2.
4) S
et the distance between the sensor and the reflective tape to 0.1 m 0.328 ft (CX-482□: 0.4 m
1.312 ft) or more.
5) Set the distance between the sensor and the reflective tape to 0.2 m 0.656 ft or more.
Swivel:
360˚ rotation
Two M3 (length 12 mm
0.472 in) screws with
washers are attached.
• RF-11
Foot biangled mounting bracket
It can also be used for mounting RF-210. The thru-beam type
sensor needs two
brackets.
Protective mounting bracket
MS-CX2-2
• MS-AJ1
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
For RF-230
• Sensing range (Note 4):
0.5 m 1.640 ft [CX-491□]
0.8 m 2.625 ft [CX-493□]
RF-11
Universal
sensor
mounting stand
(Note 2)
• MS-RF22
For RF-220
MS-RF23
Sensor
mounting
bracket (Note 1)
• MS-RF21-1
Protective mounting bracket for RF-210
It protects the reflector from damage and maintains alignment.
MS-RF22
Reflective tape
LASER
SENSORS
Reflector mounting bracket
Description
Swivel:
360˚ rotation
45˚
45˚
Elevation
angle: ±45˚
Height
adjustment:
150 mm
5.906 in
approx.
EX-40
Two M3 (length 12 mm 0.472 in)
screws with washers are attached.
CX-440
EQ-30
Sensor checker
EQ-500
• CHX-SC2
MQ-W
PO
W
Mounting hole
for M6 screw
ER
C
H
LE
VE
L
X-
SC
2
RX-LS200
RX
Sensor checker
RT-610
255
Compact Photoelectric Sensor
SPECIFICATIONS
FIBER
SENSORS
LASER
SENSORS
Standard type
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Thru-beam
Type
Model No.
MICRO
PHOTOELECTRIC
SENSORS
Item
PLC
HUMAN
MACHINE
INTERFACES
EMC Directive, RoHS Directive
Sensing object
ø50 mm ø1.969 in
or more opaque,
ø12 mm ø0.472 in
translucent or
or more opaque object (Note 4)
specular object
(Note 2, 5)
Amplifierseparated
EX-Z
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
Output
13 mA
or less
10 mA or less
Output operation
Short-circuit protection
()
0.5 mm 0.020 in or less
13 mA or less
15 mA or less
PNP open-collector transistor
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 2 V or less (at 100 mA source current)
1 V or less (at 16 mA source current)
Incorporated
1 ms or less
Operation indicator
2 ms or less
1 ms or less
Orange LED (lights up when the output is ON)(incorporated on the receiver for thru-beam type)
Stability indicator
Green LED (lights up under stable light received condition or stable dark condition)(incorporated on the receiver for thru-beam type)
Green LED (lights up when the power
is ON) (incorporated on the emitter)
Power indicator
Environmental resistance
Opaque, translucent
or transparent
object (Note 5)
Min. sensing object: ø0.5 mm
ø0.020 in copper wire
Switchable either Light-ON or Dark-ON
Response time
Continuously variable adjuster (incorporated on the receiver for thru-beam type)
Two units of sensors
can be mounted
close together with
interference prevention
filters. (Sensing range:
5 m 16.404 ft)
Incorporated (Two units of sensors can be mounted close together.)
Protection
IP67 (IEC)
Ambient temperature
-25 to +55 °C -13 to +131 °F (No dew condensation or icing allowed), Storage: -30 to +70 °C -22 to +158 °F
Ambient humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance
Incandescent light: 3,000 ℓx or less at the light-receiving face
Voltage withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Shock resistance
Emitting element (modulated)
Red LED
Infrared LED
Red LED
Peak emission wavelength 680 nm 0.027 mil 870 nm 0.034 mil 850 nm 0.033 mil 680 nm 0.027 mil 650 nm 0.026 mil
Material
Infrared LED
Infrared LED
Red LED
870 nm 0.034 mil
860 nm 0.033 mil
645 nm 0.025 mil
Enclosure: PBT (Polybutylene terephthalate), Lens: Acrylic (CX-48□: Polycarbonate), Indicator cover: Acrylic (CX-48□: Polycarbonate)
Cable
0.2 mm2 3-core (thru-beam type emitter: 2-core) cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (thru-beam type: both emitter and receiver)
Cable extension
Net
Weight
Emitter: 45 g approx., Receiver: 50 g approx.
Gross
50 g approx.
100 g approx.
80 g approx.
60 g approx.
RF-230 (Reflector): 1 pc.
Accessories
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-230 reflector. The sensing range represents the
actual sensing range of the sensor. The sensing range : A of the table below may vary depending on the shape of sensing object. Be sure to check the
operation with the actual sensing object.
Sensing
range: A
MQ-W
RT-610
1 mm 0.039 in or less
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 2
V or less (at 100 mA sink current)
1 V or less (at 16 mA sink current)
EQ-500
RX
Opaque, translucent or
transparent object (Note 5)
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Emitter: 15 mA or less Emitter: 20 mA or less Emitter: 25 mA or less
Receiver: 10 mA or less Receiver: 10 mA or less Receiver: 10 mA or less
Current consumption
EQ-30
RX-LS200
ø50 mm ø1.969 in or more
transparent, translucent or
opaque object (Note 2, 5)
0.5 mm 0.020 in or less
Supply voltage
Automatic interference
prevention function
Power Supply
Built-in
ø50 mm ø1.969 in
or more opaque
or translucent
object (Note 2, 5)
15 % or less of operation distance (Note 3)
Repeatability (perpendicular to sensing axis)
FA
COMPONENTS
Amplifier
Built-in
30 m
98.425 ft
Hysteresis
Sensitivity adjuster
Selection
Guide
15 m
49.213 ft
3 m 9.843 ft 5 m 16.404 ft 50 to 500 mm 50 to 1,000 mm 0.1 to 2 m
100 mm
300 mm
800 mm
70 to 300 mm
1.969 to 19.685 in (Note 2) 1.969 to 39.37 in (Note 2) 0.328 to 6.562 ft (Note 2) 3.937 in (Note 3) 11.811 in (Note 3) 31.496 in (Note 3) 2.756 to 11.811 in (Note 3)
(Note 2)
(Note 2)
Sensing range
ENERGY
MANAGEMENT
SOLUTIONS
UV
CURING
SYSTEMS
Narrow-view
PNP output CX-411-P CX-412-P CX-413-P CX-491-P CX-493-P CX-481-P CX-483-P CX-482-P CX-424-P CX-421-P CX-422-P CX-423-P
10 m
32.808 ft
MACHINE
VISION
SYSTEMS
Diffuse reflective
NPN output CX-411 CX-412 CX-413 CX-491 CX-493 CX-481 CX-483 CX-482 CX-424 CX-421 CX-422 CX-423
CE marking directive compliance
STATIC
CONTROL
DEVICES
LASER
MARKERS
Retroreflective
Long sensing range With polarizing filters Long sensing range For transparent object sensing
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
CX-400 SERIES Ver.2
Sensor
CX-491□
CX-493□
Sensing
object
A
0 to 3 m
0 to 9.843 ft
0 to 5 m
0 to 16.404 ft
Setting range
of the reflector: B
B
0.1 to 3 m
0.1 to 5 m
0.328 to 9.843 ft 0.328 to 16.404 ft
CX-481□
CX-483□
CX-482□
50 to 1,000 mm
50 to 500 mm
1.969 to 19.685 in 1.969 to 39.37 in
0.1 to 2 m
0.328 to 6.562 ft
100 to 500 mm 100 to 1,000 mm
3.937 to 19.685 in 3.937 to 39.37 in
0.8 to 2 m
2.625 to 6.562 ft
Reflector
3)
The sensing range and hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object.
4) If slit masks (optional) are fitted, an object of ø0.5 mm ø0.020 in (using round slit mask) can be detected.
5) Make sure to confirm detection with an actual sensor before use.
Compact Photoelectric Sensor
CX-400 SERIES Ver.2
SPECIFICATIONS
FIBER
SENSORS
LASER
SENSORS
Standard type
Model No.
Type
Item
PHOTOELECTRIC
SENSORS
Adjustable range reflective
Small spot
NPN output
CX-441
CX-443
CX-444
CX-442
MICRO
PHOTOELECTRIC
SENSORS
PNP output
CX-441-P
CX-443-P
CX-444-P
CX-442-P
AREA
SENSORS
CE marking directive compliance
EMC Directive, RoHS Directive
Adjustable range (Note 2)
20 to 50 mm 0.787 to 1.969 in
20 to 100 mm 0.787 to 3.937 in 40 to 300 mm 1.575 to 11.811 in
Sensing range (with white non-glossy paper)
2 to 50 mm 0.079 to 1.969 in
15 to 100 mm 0.591 to 3.937 in 20 to 300 mm 0.787 to 11.811 in
Hysteresis
(with white non-glossy paper)
Repeatability
Along sensing axis: 1 mm 0.039 in or less, Perpendicular to sensing axis: 0.2 mm 0.008 in or less (with white non-glossy paper)
PARTICULAR
USE
SENSORS
Current consumption
Output operation
PNP open-collector transistor
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 2 V or less (at 100 mA source current)
1 V or less (at 16 mA source current)
Switchable either Detection-ON or Detection-OFF
Short-circuit protection
1 ms or less
Operation indicator
Green LED (lights up under stable operating condition) (Note 3)
Distance adjuster
5-turn mechanical adjuster
Sensing mode
IP67 (IEC)
Ambient temperature
–25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F
Ambient humidity
Incandescent light: 3,000 ℓx or less at the light-receiving face
Voltage withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Shock resistance
Emitting element
Red LED (Peak emission wavelength: 650 nm 0.026 mil, modulated)
ø2 mm ø0.079 in approx.
(at 50 mm 1.969 in distance)
Material
ø6.5 mm ø0.256 in approx.
(at 50 mm 1.969 in distance)
ø9 mm ø0.354 in approx.
(at 100 mm 3.937 in distance)
ø15 mm ø0.591 in approx.
(at 300 mm 11.811 in distance)
Enclosure: PBT (Polybutylene terephthalate), Lens: Polycarbonate, Indicator cover: Polycarbonate
0.2 mm2 4-core cabtyre cable, 2 m 6.562 ft long
Cable
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Cable extension
Weight
Net weight: 55 g approx., Gross weight: 65 g approx.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can detect an object
2 mm 0.079 in [CX-444(-P): 15 mm 0.591 in, CX-442(-P): 20 mm 0.787 in], or more, away.
Actual sensing range
of the sensor: A
Adjustable range: B
Sensing
object
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
Incorporated
Protection
MEASUREMENT
SENSORS
PLC
BGS/FGS functions Switchable with wiring of sensing mode selection input
Automatic interference prevention function (Note 4)
WIRE-SAVING
SYSTEMS
LASER
MARKERS
Orange LED (lights up when the output is ON)
Stability indicator
SIMPLE
WIRE-SAVING
UNITS
STATIC
CONTROL
DEVICES
Incorporated
Response time
Environmental resistance
SENSOR
OPTIONS
20 mA or less
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 2
V or less (at 100 mA sink current)
1 V or less (at 16 mA sink current)
Spot diameter
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Output
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
5 % or less of operation distance
2 % or less of operation distance
Supply voltage
256
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
EX-Z
CX-400
CY-100
EX-10
EX-20
CX-441□/443□
CX-444□
CX-442□
EX-30
A
2 to 50 mm
0.079 to 1.969 in
15 to 100 mm
0.591 to 3.937 in
20 to 300 mm
0.787 to 11.811 in
EX-40
B
20 to 50 mm
0.787 to 1.969 in
20 to 100 mm
0.787 to 3.937 in
40 to 300 mm
1.575 to 11.811 in
3) Refer to ‘‘Stability indicator (p.267)’’ of ‘‘PRECAUTIONS FOR PROPER USE’’ for operation of the stability indicator.
4) Note that detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to
check the operation with the actual sensing object.
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
257
Compact Photoelectric Sensor
SPECIFICATIONS
FIBER
SENSORS
LASER
SENSORS
Basic type
PHOTOELECTRIC
SENSORS
Thru-beam
Type
AREA
SENSORS
Item
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
CX-411A-C05
CX-411B-C05
CX-412A-C05
CX-412B-C05
CX-491A-C05-Y
CX-491B-C05-Y
PNP output
CX-411A-P-C05
CX-411B-P-C05
CX-412A-P-C05
CX-412B-P-C05 CX-491A-P-C05-Y CX-491B-P-C05-Y
EMC Directive, RoHS Directive
10 m 32.808 ft
15 m 49.213 ft
ø12 mm ø0.472 in or more opaque object (Note 3)
3 m 9.843 ft (Note 2)
ø50 mm ø1.969 in or more transparent,
translucent or opaque object (Note 2, 4)
0.5 mm 0.020 in or less
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Emitter: 15 mA or less
Receiver: 10 mA or less
Current consumption
STATIC
CONTROL
DEVICES
Emitter: 20 mA or less
Receiver: 10 mA or less
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 2
V or less (at 100 mA sink current)
1 V or less (at 16 mA sink current)
Output
MEASUREMENT
SENSORS
Short-circuit protection
Orange LED (lights up when the output is ON)(incorporated on the receiver for thru-beam type)
Stability indicator
Green LED (lights up under stable light received condition or stable dark condition)(incorporated on the receiver for thru-beam type)
Power indicator
HUMAN
MACHINE
INTERFACES
PNP open-collector transistor
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 2
V or less (at 100 mA source current)
1 V or less (at 16 mA source current)
1 ms or less
Operation indicator
PLC
13 mA or less
Incorporated
Response time
LASER
MARKERS
Green LED (lights up when the power is ON) (incorporated on the emitter)
Sensitivity adjuster
ENERGY
MANAGEMENT
SOLUTIONS
Two units of sensors can be mounted
close together with interference prevention
filters. (Sensing range: 5 m 16.404 ft)
Automatic interference
prevention function
Environmental resistance
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
IP67 (IEC)
Ambient temperature
–25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F
Ambient humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance
Incandescent light: 3,000 ℓx or less at the light-receiving face
Voltage withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Emitting element (modulated)
Amplifier
Built-in
Peak emission wavelength
Power Supply
Built-in
Amplifierseparated
Infrared LED
Red LED
870 nm 0.034 mil
680 nm 0.027 mil
Enclosure: PBT (Polybutylene terephthalate), Lens: Acrylic, Indicator cover: Acrylic
Cable
0.2 mm2 3-core (thru-beam type emitter: 2-core) cabtyre cable, 0.5 m 1.640 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (thru-beam type: both emitter and receiver)
Net
Weight
CX-400
Red LED
680 nm 0.027 mil
Material
Cable extension
EX-Z
Incorporated (Two units of sensors can
be mounted close together.)
Protection
Shock resistance
Selection
Guide
Emitter: 20 g approx., Receiver: 20 g approx.
20 g approx.
50 g approx.
30 g approx.
Gross
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-230 reflector (optional). The sensing range
represents the actual sensing range of the sensor. The sensing range : A of the table below may vary depending on the shape of sensing object. Be
sure to check the operation with the actual sensing object.
EX-30
Sensing
range: A
EX-40
CX-440
EQ-30
Sensor
EQ-500
RT-610
Dark-ON
NPN output
Supply voltage
WIRE-SAVING
SYSTEMS
RX
Light-ON
Hysteresis
SIMPLE
WIRE-SAVING
UNITS
MQ-W
Dark-ON
Repeatability (perpendicular to sensing axis)
SENSOR
OPTIONS
RX-LS200
With polarizing filters
Light-ON
Sensing object
PARTICULAR
USE
SENSORS
EX-20
Long sensing range
Dark-ON
Sensing range
INDUCTIVE
PROXIMITY
SENSORS
Retroreflective
Light-ON
CE marking directive compliance
PRESSURE /
FLOW
SENSORS
EX-10
Model No.
MICRO
PHOTOELECTRIC
SENSORS
CY-100
CX-400 SERIES Ver.2
CX-491□
Sensing
object
A
0 to 3 m
0 to 9.843 ft
Setting range
of the reflector: B
B
0.1 to 3 m
0.328 to 9.843 ft
Reflector
(Optional)
3) If slit masks (optional) are fitted, an object of ø0.5 mm ø0.020 in (using round slit mask) can be detected.
4) Make sure to confirm detection with an actual sensor before use.
Compact Photoelectric Sensor
CX-400 SERIES Ver.2
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
LASER
SENSORS
NPN output type
I/O circuit diagram
Sensor circuit
Tr
Color code / Connector pin No. of the connector type
Wiring diagram
PHOTOELECTRIC
SENSORS
Brown
(Brown / 1) +V
D
(Black / 4)
Output (Note 1)
D
ZD
ZD
Black (Note 1)
Load
+
–
100 mA max.
(Blue / 3) 0 V
(Pink / 2) Sensing mode
selection input (Note 2, 3)
Internal circuit
12 to 24 V DC
±10 %
Load
+
–
12 to 24 V DC
±10 %
Blue
Pink (Note 2, 3)
User’s circuit
Notes: 1) The emitter of the thru-beam type sensor does not incorporate the black wire.
2) T
he pink wire is incorporated only for the CX-44□ adjustable range
reflective type. When using the CX-44□, be sure to wire the pink
wire as mentioned *1. Unstable operation may occur.
3) W
hen the mating cable is connected to the plug-in connector type
of CX-44□, its color is white.
*1
BGS function: Connect to 0 V
FGS function: Connect to +V
M8 plug-in connector type
BGS function: Connect to 0 V
FGS function: Connect to +V
2
Sensing mode
selection input
(Note 2)
Symbols ... D : Reverse supply polarity protection diode
ZD : Surge absorption zener diode
Tr : NPN output transistor
1
2
Not
connected
3
0V
1
+V
3
0V
4
Output (Note 1)
PNP output type
Sensor circuit
Color code / Connector pin No. of the connector type
Wiring diagram
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
MACHINE
VISION
SYSTEMS
Brown
(Brown / 1) +V
100 mA max.
(Black / 4) Output (Note 1)
(Blue / 3) 0 V
Load
+
–
12 to 24 V DC
±10 %
User’s circuit
Notes: 1) The emitter of the thru-beam type sensor does not incorporate the
output.
2) Sensing mode selection input is incorporated only for the
CX-44□-P adjustable range reflective type. When using the
CX-44□-P, be sure to wire the sensing mode selection input (pink /
2) as mentioned *1. Unstable operation may occur.
3) When the mating cable is connected to the plug-in connector type
of CX-44□-P, its color is white.
*1
• Sensing mode selection input
BGS function: Connect to 0 V
FGS function: Connect to +V
Symbols ... D : Reverse supply polarity protection diode
ZD : Surge absorption zener diode
Tr : PNP output transistor
+
–
Black (Note 1)
Load
Blue
12 to 24 V DC
±10 %
UV
CURING
SYSTEMS
*1
*1
(Pink / 2) Sensing mode
selection input (Note 2, 3)
Internal circuit
MEASUREMENT
SENSORS
FA
COMPONENTS
I/O circuit diagram
D
D
PARTICULAR
USE
SENSORS
STATIC
CONTROL
DEVICES
Notes: 1) The emitter of the thru-beam type sensor does not incorporate the output.
2) S
ensing mode selection input is incorporated only for the
CX-44□ adjustable range reflective type. When using the
CX-44□, be sure to wire the sensing mode selection input (pink /
2). Unstable operation may occur.
ZD
ZD
INDUCTIVE
PROXIMITY
SENSORS
SIMPLE
WIRE-SAVING
UNITS
M12 pigtailed type
4
Output
(Note 1)
+V
PRESSURE /
FLOW
SENSORS
WIRE-SAVING
SYSTEMS
Connector pin position
• Sensing mode selection input
AREA
SENSORS
SENSOR
OPTIONS
• Sensing mode selection input
*1
MICRO
PHOTOELECTRIC
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
*1
*1
Notes: 1) The emitter of the thru-beam type sensor does not incorporate the
output.
2) Sensing mode selection input is incorporated only for the
CX-44□ adjustable range reflective type. When using the
CX-44□, be sure to wire the sensing mode selection input (pink / 2)
as mentioned *1. Unstable operation may occur.
3) When the mating cable is connected to the plug-in connector type
of CX-44□, its color is white.
Tr
258
Pink (Note 2, 3)
Selection
Guide
Notes: 1) The emitter of the thru-beam type sensor does not incorporate the black wire.
2) T
he pink wire is incorporated only for the CX-44□-P adjustable range
reflective type. When using the CX-44□-P, be sure to wire the pink
wire as mentioned *1. Unstable operation may occur.
3) W
hen the mating cable is connected to the plug-in connector type
of CX-44□-P, its color is white.
*1
2
Sensing mode
selection input
(Note 2)
1
+V
4
Output (Note 1)
3
0V
Amplifierseparated
CX-400
BGS function: Connect to 0 V
FGS function: Connect to +V
M8 plug-in connector type
Power Supply
Built-in
EX-Z
• Sensing mode selection input
Connector pin position
Amplifier
Built-in
CY-100
EX-10
M12 pigtailed type
2
Not
connected
1
+V
EX-20
EX-30
EX-40
CX-440
EQ-30
3
0V
4
Output (Note 1)
Notes: 1) The emitter of the thru-beam type sensor does not incorporate the output.
2) S
ensing mode selection input is incorporated only for the
CX-44□-P adjustable range reflective type. When using the
CX-44□-P, be sure to wire the sensing mode selection input (pink /
2). Unstable operation may occur.
EQ-500
MQ-W
RX-LS200
RX
RT-610
259
SENSING CHARACTERISTICS (TYPICAL)
FIBER
SENSORS
CX-411□
Thru-beam type
0
400
15.748
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Parallel deviation with round
slit masks (ø2 mm ø0.079 in)
0
100
3.937
HUMAN
MACHINE
INTERFACES
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
Power Supply
Built-in
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
Setting distance L (mm in)
Vertical
direction
Emitter
ℓ
L
L
Angular deviation
20
65.617
15
49.213
15
49.213
10
32.808
Emitter
5
16.404
0
1,000
39.370
2 Horizontal
6.562 direction
Emitter
1
3.281
ℓ
20
0
20
40
0.787
0.787
1.575
Center
Left
Right
Operating point ℓ (mm in)
Parallel deviation with rectangular
slit masks (2 × 6 mm 0.079 × 0.236 in)
Slit on one side
Horizontal
direction
6
19.685
Slit on both sides
Horizontal
direction
Vertical
direction
Emitter
Slit on both sides
Vertical direction
ℓ
L
L
Slit on one side
Vertical
direction
4
Slit on both sides Slit on both sides
Horizontal
13.123 Horizontal
Vertical direction
direction
direction
Emitter
Receiver
Receiver
0
0
200
100
100
200
7.874
7.874
3.937
3.937
(Down) Left
Right (Up)
Center
Operating point ℓ (mm in)
ℓ
L
Receiver
800
31.496
2
6.562
ℓ
θ L
10
32.808
ℓ
L
Receiver
5
16.404
20
0
20
Center
Left
Right
Operating angle θ( ° )
1
3.281
0
400
15.748
Slit on
both sides
Emitter
ℓ
L
Receiver
200
0
200
400
7.874
7.874 15.748
Center
Left
Right
Operating point ℓ (mm in)
Slit on one side Slit on one side
Horizontal Vertical
direction
direction
3
9.843
2
6.562 Horizontal
direction
Emitter
1
3.281
ℓ
L
Vertical
direction
Emitter
ℓ
L
Receiver
Receiver
0
400
200
0
200
400
15.748 7.874
7.874 15.748
(Down) Left
Right (Up)
Center
Operating point ℓ (mm in)
L
Receiver
Parallel deviation with rectangular
slit masks (1 × 6 mm 0.039 × 0.236 in)
Horizontal
2 direction
6.562 Emitter
ℓ
L
1.5
4.921
1
3.281
Emitter
0.5
1.640
ℓ
L
Receiver
Receiver
0
400
200
0
200
400
15.748 7.874
7.874 15.748
(Down) Left
Right (Up)
Center
Operating point ℓ (mm in)
L
Receiver
100
0
100
200
3.937
3.937
7.874
Center
Left
Right
Operating point ℓ (mm in)
Parallel deviation with rectangular
slit masks (2 × 6 mm 0.079 × 0.236 in)
Slit on one side Slit on one side
Horizontal
Vertical
direction
direction
6
19.685
Vertical
direction
Emitter
ℓ
Slit on
both sides
8
26.247
Slit on one side Slit on one side
Vertical
Horizontal
direction
direction
Slit on both sides
Horizontal and
Vertical direction
Slit on
one side
0
200
7.874
0
50
50
100
1.969
1.969
3.937
Center
Left
Right
Operating point ℓ (mm in)
4
13.123
Slit on both sides
Horizontal and
Vertical direction
ℓ
Slit on
both sides
0
100
3.937
40
4
13.123
Slit on
one side
Emitter
200
7.874
4
13.123
2
6.562
L
Parallel deviation with round
slit masks (ø1 mm ø0.039 in)
2
6.562
400
15.748
Parallel deviation with rectangular
slit masks (0.5 × 6 mm 0.020 × 0.236 in)
3
9.843
Vertical
direction
Emitter
Receiver
Receiver
0
200
100
100
200
0
7.874
3.937
3.937
7.874
(Down) Left
Right (Up)
Center
Operating point ℓ (mm in)
Slit on
one side
600
23.622
Emitter
0
40
500
500
1,000
0
19.685
19.685 39.370
Center
Left
Right
Operating point ℓ (mm in)
Parallel deviation with round
slit masks (ø0.5 mm ø0.020 in)
Parallel deviation with round
slit masks (ø2 mm ø0.079 in)
Setting distance L (m ft)
EX-10
Slit on
both sides
Horizontal
direction
Receiver
0
40
1.575
8
26.247
Slit on one side Slit on one side
Vertical
Horizontal
direction
direction
L
Thru-beam type
20
65.617
EX-Z
CY-100
ℓ
Slit on
both sides
Vertical
direction
Receiver
Receiver
0
0
100
50
50
100
3.937
1.969
1.969
3.937
(Down) Left
Right (Up)
Center
Operating point ℓ (mm in)
50
0
50
100
3.937
1.969
1.969
Center
Left
Right
Operating point ℓ (mm in)
Parallel deviation
Amplifierseparated
CX-400
Receiver
Setting distance L (m ft)
Amplifier
Built-in
L
Horizontal
1 direction
3.281 Emitter
Parallel deviation with rectangular
slit masks (1 × 6 mm 0.039 × 0.236 in)
Emitter
ℓ
CX-412□
UV
CURING
SYSTEMS
Selection
Guide
Emitter
ℓ
PLC
ENERGY
MANAGEMENT
SOLUTIONS
Slit on
both sides
1
3.281
Slit on
both sides
Receiver
3
9.843
Slit on one side
Horizontal
direction
400
15.748
0
10
10
20
0.787
0.394
0.394
Center
Left
Right
Operating point ℓ (mm in)
4
13.123
Slit on one side
Vertical
direction
2
6.562
0
20
0.787
40
Parallel deviation with rectangular
slit masks (0.5 × 6 mm 0.020 × 0.236 in)
Slit on
one side
2
6.562
20
0
20
Center
Left
Right
Operating angle θ ( ° )
Slit on
one side
Setting distance L (m ft)
LASER
MARKERS
0
40
L
ℓ
800
31.496
Setting distance L (m ft)
STATIC
CONTROL
DEVICES
Setting distance L (m ft)
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Setting distance L (m ft)
Receiver
Emitter
Slit on
both sides
200
7.874
Receiver
200
200
400
0
7.874
7.874 15.748
Center
Left
Right
Operating point ℓ (mm in)
Slit on
one side
Setting distance L (mm in)
SIMPLE
WIRE-SAVING
UNITS
L
ℓ
θ L
5
16.404
Setting distance L (m ft)
INDUCTIVE
PROXIMITY
SENSORS
Emitter
5
16.404
400
15.748
Emitter
Setting distance L (m ft)
PRESSURE /
FLOW
SENSORS
Setting distance L (m ft)
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
10
32.808
10
32.808
Setting distance L (m ft)
AREA
SENSORS
Parallel deviation with round
slit masks (ø1 mm ø0.039 in)
Setting distance L (mm in)
Parallel deviation with round
slit masks (ø0.5 mm ø0.020 in)
Angular deviation
Setting distance L (m ft)
Parallel deviation
MICRO
PHOTOELECTRIC
SENSORS
Setting distance L (m ft)
PHOTOELECTRIC
SENSORS
Please contact our office for the sensing characteristics of CX-413 and CX-483.
Setting distance L (m ft)
LASER
SENSORS
CX-400 SERIES Ver.2
Compact Photoelectric Sensor
Slit on both sides
Horizontal and
Vertical direction
4 Horizontal
13.123 direction
Emitter
2
6.562
ℓ
L
Vertical
direction
Emitter
ℓ
L
Receiver
Receiver
0
800
400
400
800
0
31.496 15.748
15.748 31.496
(Down) Left
Right (Up)
Center
Operating point ℓ (mm in)
Compact Photoelectric Sensor
SENSING CHARACTERISTICS (TYPICAL)
Angular deviation
4
13.123
4
13.123
Reflector
(RF-230)
ℓ
2
6.562
L
1
3.281
1
3.281
0
200
7.874
Sensor
angular
deviation
Reflector (RF-230)
θ L
2
6.562
Sensor
0
40
100
0
100
200
3.937
3.937
7.874
Center
Left
Right
Operating point ℓ (mm in)
CX-481□
θ
20
0
20
Center
Left
Right
Operating angle θ ( ° )
Setting distance L (mm in)
Setting distance L (mm in)
400
15.748
ℓ
Sensor
200
7.874
Sensor
Reflector
angular
Reflector
deviation
angular Reflector (RF-230)
deviation
200
7.874
0
40
50
0
50
100
1.969
1.969
3.937
Center
Left
Right
Operating point ℓ (mm in)
6
19.685
0
200
7.874
40
Sensor angular
deviation
Reflector (RF-230)
θ
L
400
15.748
L
6
19.685
Reflector
(RF-230)
ℓ
L
Sensor
angular
deviation
θ L
Sensor
20
0
20
Center
Left
Right
Operating angle θ ( ° )
40
CX-482□
0
20
0.787
Sensing range L (mm in)
Setting distance L (mm in)
50
1.969
L
Sensor
100
3.937
a × a mm
White non-glossy paper
50
1.969
0
200 × 200 mm
7.874 × 7.874 in
White nonglossy paper
ℓ
L
Sensor
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
2
6.562
2
6.562
Reflector
(RF-230)
1
3.281
0
200
7.874
ℓ
L
Sensor
100
0
100
200
3.937
3.937
7.874
Center
Left
Right
Operating point ℓ (mm in)
1
3.281
0
40
MEASUREMENT
SENSORS
Sensor
angular
deviation
Sensor
angular
deviation
θ L Reflector
(RF-230)
Sensor
Reflector
angular
deviation
Reflector
angular
deviation
Reflector
θ L
(RF-230)
Sensor
20
0
20
Center
Left
Right
Operating angle θ ( ° )
40
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
As the sensing object size becomes smaller than the standard
size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the
sensing range shortens, as shown in the left graph.
For plotting the left graph, the sensitivity has been set such that
a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just
detectable at a distance of 100 mm 3.937 in.
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Amplifier
Built-in
50
100
150
1.969
3.937
5.906
White non-glossy paper
side length a (mm in)
200
7.874
Power Supply
Built-in
Amplifierseparated
As the sensing object size becomes smaller than the standard
size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the
sensing range shortens, as shown in the left graph.
For plotting the left graph, the sensitivity has been set such that
a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just
detectable at a distance of 300 mm 11.811 in.
400
15.748
300
11.811
200
7.874
a × a mm
White nonglossy paper
100
3.937
L
0
PARTICULAR
USE
SENSORS
Selection
Guide
50
100
150
1.969
3.937
5.906
White non-glossy paper
side length a (mm in)
EX-Z
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
Sensor
20
0
20
40
0.787
0.787
1.575
Center
Left
Right
Operating point ℓ (mm in)
INDUCTIVE
PROXIMITY
SENSORS
SIMPLE
WIRE-SAVING
UNITS
Angular deviation
Correlation between sensing object size and sensing range
100
3.937
0
40
1.575
Sensor
Sensor
20
0
20
40
Center
Left
Right
Operating angle θ( ° )
Diffuse reflective type
Sensing range L (mm in)
Setting distance L (mm in)
200
7.874
PRESSURE /
FLOW
SENSORS
Sensor
Sensing field
300
11.811
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
Retroreflective type
CX-421□
400
15.748
Sensor
Sensor
angular
deviation
Reflector (RF-230)
θ
L
AREA
SENSORS
Reflector
angular
deviation
Sensor
angular
deviation
Reflector angular
deviation
Reflector
(RF-230) θ
L
L
10
0
10
20
0.394
0.394
0.787
Center
Left
Right
Operating point ℓ (mm in)
LASER
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Correlation between sensing object size and sensing range
200 × 200 mm
7.874 × 7.874 in
White non-glossy paper
FIBER
SENSORS
PHOTOELECTRIC
SENSORS
Diffuse reflective type
Sensing field
ℓ
2
6.562
0
40
100
0
100
200
3.937
3.937
7.874
Center
Left
Right
Operating point ℓ (mm in)
CX-424□
100
3.937
4
13.123
Sensor
Parallel deviation
600
23.622
Reflector
(RF-230)
8
26.247
Sensor
800
31.496
600
23.622
8
26.247
2
6.562
L
Angular deviation
800
31.496
Angular deviation
4
13.123
Retroreflective type
Parallel deviation
0
100
3.937
Sensor
angular
deviation
Reflector
angular
deviation
Reflector (RF-230)
Sensor
Parallel deviation
Setting distance L (m ft)
3
9.843
Setting distance L (m ft)
Setting distance L (m ft)
3
9.843
Reflector
angular
deviation
Retroreflective type
Setting distance L (m ft)
Parallel deviation
CX-493□
Setting distance L (m ft)
Retroreflective type
260
Please contact our office for the sensing characteristics of CX-413 and CX-483.
Setting distance L (m ft)
CX-491□
CX-400 SERIES Ver.2
EQ-500
200
7.874
MQ-W
RX-LS200
RX
RT-610
261
Compact Photoelectric Sensor
SENSING CHARACTERISTICS (TYPICAL)
FIBER
SENSORS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
1,000
39.370
SIMPLE
WIRE-SAVING
UNITS
200 × 200 mm
7.874 × 7.874 in
White nonglossy paper
ℓ
500
19.685
LASER
MARKERS
200
7.874
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
EX-Z
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
50
100
150
1.969
3.937
5.906
White non-glossy paper
side length a (mm in)
200
7.874
As the sensing object size becomes smaller than the standard
size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the
sensing range shortens, as shown in the left graph.
White
200
7.874
N6
100 200 × 200 mm
3.937 7.874 × 7.874 in
Non-glossy paper
100
3.937
ℓ
L
Sensor
0
2
0.079
For plotting the left graph, the sensitivity has been set such
that a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper
is just detectable at a distance of 200 mm 7.874 in. Contact us
for the sensing characteristics of 300 mm 11.811 in distance.
Please contact us for the sensing field at the setting distance
300 mm 11.811 in.
N6
a × a mm
Non-glossy paper
L
Sensor
1
0
1
2
0.039
0.039
0.079
Center
Left
Right
Operating point ℓ (mm in)
0
50
100
150
1.969
3.937
5.906
Non-glossy paper
side length a (mm in)
200
7.874
Correlation between lightness and sensing range
Sensing range L (mm in)
200
7.874
Sensing
region
100
3.937
Selection
Guide
0
Correlation between sensing object size and sensing range
FA
COMPONENTS
UV
CURING
SYSTEMS
Sensor
White
HUMAN
MACHINE
INTERFACES
MACHINE
VISION
SYSTEMS
L
Diffuse reflective type
Sensing field
PLC
ENERGY
MANAGEMENT
SOLUTIONS
a × a mm
White nonglossy paper
400
15.748
CX-423□
Setting distance L (mm in)
STATIC
CONTROL
DEVICES
As the sensing object size becomes smaller than the standard
size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the
sensing range shortens, as shown in the left graph.
For plotting the left graph, the sensitivity has been set such that
a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just
detectable at a distance of 800 mm 31.496 in.
800
31.496
20
0
20
40
0.787
0.787
1.575
Center
Left
Right
Operating point ℓ (mm in)
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
L
Sensor
0
40
1.575
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Correlation between sensing object size and sensing range
0
Dark
N2
N4
N6
Lightness
N8
The sensing region is
represented by oblique lines in
the left figure.
However, the sensitivity should
be set with an enough margin
because of slight variation in
products.
Emitted beam
250
9.843
200
7.874
150
5.906
110
4.331
100
3.937
ø2.5 mm
ø0.098 in
ø2 mm
ø0.079 in
ø2.2 mm
ø0.087 in
50
1.969
ø4 mm
ø0.157 in
0
Light
N1 N2 N3 N4 N5 N6 N7 N8 N9
Lightness shown on the left may
differ slightly from the actual
object condition.
ø5 mm
ø0.197 in
Visible spot range
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
Sensing field
Distance L (mm in)
AREA
SENSORS
Diffuse reflective type
Sensing range L (mm in)
MICRO
PHOTOELECTRIC
SENSORS
CX-422□
Sensing range L (mm in)
PHOTOELECTRIC
SENSORS
Setting distance L (mm in)
LASER
SENSORS
CX-400 SERIES Ver.2
Compact Photoelectric Sensor
CX-400 SERIES Ver.2
SENSING CHARACTERISTICS (TYPICAL)
FIBER
SENSORS
CX-441□
Adjustable range reflective type
Sensing fields
80
3.150
Gray non-glossy paper
Lightness: 5
30
1.181
20
0.787
60
2.362
50 × 50 mm
1.969 × 1.969 in
Non-glossy paper
10
0.394
ℓ
L
4
0.157
Gray non-glossy paper
Lightness: 5
50 × 50 mm
1.969 × 1.969 in
Non-glossy paper
20
0.787
Sensor
0
White nonglossy paper
40
1.575
0
4
0.157
2
0
2
4
0.079
0.079
0.157
Center
Left
Right
Operating point ℓ (mm in)
MICRO
PHOTOELECTRIC
SENSORS
80
3.150
L
ℓ
Sensor
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
ø2 mm 0.079 in
ø2 mm 0.079 in
PRESSURE /
FLOW
SENSORS
ø3 mm 0.118 in
INDUCTIVE
PROXIMITY
SENSORS
ø3 mm 0.118 in
0
2
0
2
4
0.079
0.079
0.157
Center
Left
Right
Operating point ℓ (mm in)
Correlation between color
(50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range
AREA
SENSORS
60
2.362
50
1.969
40
1.575
30
1.181
20
0.787
Distance L (mm in)
Setting distance L (mm in)
White nonglossy paper
Setting distance L (mm in)
• Setting distance: 50 mm 1.969 in
40
1.575
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Emitted beam
• Setting distance: 25 mm 0.984 in
262
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Correlation between material
(50 × 50 mm 1.969 × 1.969 in) and sensing range
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
25
0.984
Black rubber
0
Plywood
mm
…25
0.984 in
Cardboard
Black
Blue
Gray
Green
Red
Brown
Orange
White
0
Yellow
mm
…25
0.984 in
Gray non-glossy
paper (Lightness: 5)
25
0.984
mm
…50
1.969 in
White nonglossy paper
mm
…50
1.969 in
50
1.969
Sensing range L (mm in)
Sensing range L (mm in)
50
1.969
These bars indicate the
sensing range with the
respective colors when
the distance adjuster is
set to a sensing range
of 50 mm 1.969 in and
25 mm 0.984 in long,
respectively, with white
color.
The sensing range also
varies depending on
material.
CX-443□
2
0
2
4
0.079
0.079
0.157
Center
Left
Right
Operating point ℓ (mm in)
0
4
0.157
Gray non-glossy paper
Lightness: 5
Correlation between color
(50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range
Sensing range L (mm in)
50
1.969
mm
…50
1.969 in
25
0.984
Black
Gray
Blue
Green
Brown
Red
Orange
White
0
Yellow
mm
…25
0.984 in
These bars indicate
the sensing range with
the respective colors
when the distance
adjuster is set to a
sensing range of
50 mm 1.969 in and
25 mm 0.984 in long,
respectively, with white
color.
The sensing range
also varies depending
on material.
HUMAN
MACHINE
INTERFACES
FA
COMPONENTS
Selection
Guide
ø6.2 mm 0.244 in
ø5.9 mm 0.232 in
Amplifier
Built-in
ø5.3 mm 0.209 in
Power Supply
Built-in
Amplifierseparated
0
2
0
2
4
0.079
0.079
0.157
Center
Left
Right
Operating point ℓ (mm in)
PLC
ø6.5 mm 0.256 in
EX-Z
Correlation between material
(50 × 50 mm 1.969 × 1.969 in) and sensing range
50
1.969
mm
…50
1.969 in
25
0.984
mm
…25
0.984 in
0
Black rubber
4
0.157
White nonglossy paper
60
2.362
50
1.969
40
1.575
30
1.181
20
0.787
Plywood
0
20
0.787
Sensor
Cardboard
Gray non-glossy paper
Lightness: 5
10
0.394
ℓ
Gray non-glossy
paper (Lightness: 5)
40
1.575
White nonglossy paper
L
White nonglossy paper
60
2.362
LASER
MARKERS
UV
CURING
SYSTEMS
80
3.150
50 × 50 mm 1.969 × 1.969 in
Non-glossy paper
Distance L (mm in)
ℓ
Sensor
20
0.787
80
3.150
Sensing range L (mm in)
L
30
1.181
• Setting distance: 50 mm 1.969 in
Setting distance L (mm in)
Setting distance L (mm in)
50 × 50 mm 1.969 × 1.969 in
Non-glossy paper
STATIC
CONTROL
DEVICES
MACHINE
VISION
SYSTEMS
Emitted beam
• Setting distance: 25 mm 0.984 in
MEASUREMENT
SENSORS
ENERGY
MANAGEMENT
SOLUTIONS
Adjustable range reflective type
Sensing fields
40
1.575
These bars indicate
the sensing range
with the respective
objects when the
distance adjuster is
set to a sensing range
of 50 mm 1.969 in
and 25 mm 0.984 in
long, respectively,
with white non-glossy
paper.
These bars indicate
the sensing range
with the respective
objects when the
distance adjuster is
set to a sensing range
of 50 mm 1.969 in
and 25 mm 0.984 in
long, respectively,
with white non-glossy
paper.
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
263
Compact Photoelectric Sensor
SENSING CHARACTERISTICS (TYPICAL)
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Sensing fields
White nonglossy paper
30
1.181
20
0.787
• Setting distance: 50 mm 1.969 in
• Setting distance: 100 mm 3.937 in
80
3.150
40
1.575
Gray non-glossy paper
Lightness: 5
50 × 50 mm
1.969 × 1.969 in
Non-glossy paper
L
0
10
0.394
SENSOR
OPTIONS
ℓ
40
1.575
Gray non-glossy paper
Lightness: 5
0
10
0.394
5
0
5
10
0.394
0.197
0.197
Center
Left
Right
Operating point ℓ (mm in)
100
3.937
50 × 50 mm
1.969 × 1.969 in
Non-glossy paper
20
0.787
Sensor
White nonglossy paper
White nonglossy paper
60
2.362
10
0.394
PARTICULAR
USE
SENSORS
SIMPLE
WIRE-SAVING
UNITS
Emitted beam
• Setting distance: 25 mm 0.984 in
ℓ
L
Setting distance L (mm in)
AREA
SENSORS
Adjustable range reflective type
Setting distance L (mm in)
MICRO
PHOTOELECTRIC
SENSORS
CX-444□
Setting distance L (mm in)
PHOTOELECTRIC
SENSORS
Gray non-glossy paper
Lightness: 5
50 × 50 mm
1.969 × 1.969 in
Non-glossy paper
50
1.969
ℓ
L
Sensor
Sensor
0
10
0.394
5
0
5
10
0.197
0.197
0.394
Center
Left
Right
Operating point ℓ (mm in)
Correlation between color
(50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range
100
3.937
ø9 mm ø0.354 in
80
3.150
ø8 mm ø0.315 in
50
1.969
ø6.5 mm ø0.256 in
20
0.787
ø5.3 mm ø0.209 in
Distance L (mm in)
FIBER
SENSORS
LASER
SENSORS
CX-400 SERIES Ver.2
0
5
0
5
10
0.197
0.197
0.394
Center
Left
Right
Operating point ℓ (mm in)
Correlation between material
(50 × 50 mm 1.969 × 1.969 in) and sensing range
WIRE-SAVING
SYSTEMS
Emitted beam
White nonglossy paper
200
7.874
50 × 50 mm
1.969 × 1.969 in
Non-glossy paper
50
1.969
0
10
0.394
EX-Z
RT-610
300 mm
…11.811 in
200 mm
…7.874 in
…100 mm
3.937 in
100
3.937
0
50 × 50 mm
1.969 × 1.969 in
Non-glossy paper
100
3.937
L
0
10
0.394
5
0
5
10
0.197
0.197
0.394
Center
Left
Right
Operating point ℓ (mm in)
# ℓ
Sensor
5
0
5
10
0.197
0.197
0.394
Center
Left
Right
Operating point ℓ (mm in)
300
11.811
□15 mm □0.591 in
200
7.874
□11 mm □0.433 in
100
3.937
1.181
30
□9 mm □0.354 in
ø8 mm ø0.315 in
0
Correlation between material
(50 × 50 mm 1.969 × 1.969 in) and sensing range
These bars indicate the
sensing range with the
respective colors when
the distance adjuster is
set to a sensing range
of 300 mm 11.811 in,
200 mm 7.874 in and
100 mm 3.937 in long,
respectively, with white
color.
The sensing range also
varies depending on
material.
300
11.811
200
7.874
300 mm
…11.811 in
200 mm
…7.874 in
…100 mm
3.937 in
100
3.937
0
Black rubber
RX
0
10
0.394
200
7.874
Plywood
MQ-W
RX-LS200
# ℓ
White nonglossy paper
300
11.811
Cardboard
EQ-500
200
7.874
Black
EQ-30
Gray
CX-440
L
Sensor
300
11.811
Blue
EX-40
50 × 50 mm
1.969 × 1.969 in
Non-glossy paper
400
15.748
Gray non-glossy paper
Lightness: 5
400
15.748
Green
EX-30
Gray non-glossy paper
Lightness: 5
400
15.748
Brown
EX-20
Red
EX-10
100
3.937
• Setting distance: 300 mm 11.811 in
400
15.748
White nonglossy paper
Correlation between color
(50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range
White
CY-100
5
0
5
10
0.197
0.197
0.394
Center
Left
Right
Operating point ℓ (mm in)
Sensing range L (mm in)
CX-400
ℓ
L
Sensor
Orange
Amplifierseparated
Gray non-glossy paper
Lightness: 5
Yellow
Power Supply
Built-in
Setting distance L (mm in)
Amplifier
Built-in
• Setting distance: 200 mm 7.874 in
Distance L (mm in)
• Setting distance: 100 mm 3.937 in
100
3.937
Selection
Guide
Plywood
Sensing fields
Gray non-glossy
paper (Lightness: 5)
UV
CURING
SYSTEMS
These bars indicate
the sensing range with
the respective objects
when the distance
adjuster is set to a
sensing range of 100
mm 3.937 in and 50
mm 1.969 in long,
respectively, with white
non-glossy paper.
Adjustable range reflective type
White nonglossy paper
MACHINE
VISION
SYSTEMS
CX-442□
Setting distance L (mm in)
FA
COMPONENTS
Black rubber
ENERGY
MANAGEMENT
SOLUTIONS
0
Cardboard
Black
Blue
Gray
Green
Red
Brown
Orange
White
Yellow
0
HUMAN
MACHINE
INTERFACES
mm
…50
1.969 in
Gray non-glossy
paper (Lightness: 5)
mm
…50
1.969 in
PLC
mm
…100
3.937 in
50
1.969
White nonglossy paper
mm
…100
3.937 in
Sensing range L (mm in)
50
1.969
100
3.937
Setting distance L (mm in)
LASER
MARKERS
These bars indicate the
sensing range with the
respective colors when
the distance adjuster is
set to a sensing range
of 100 mm 3.937 in
and 50 mm 1.969 in
long, respectively, with
white color.
The sensing range also
varies depending on
material.
Sensing range L (mm in)
STATIC
CONTROL
DEVICES
100
3.937
Sensing range L (mm in)
MEASUREMENT
SENSORS
These bars indicate
the sensing range with
the respective objects
when the distance
adjuster is set to a
sensing range of
300 mm 11.811 in,
200 mm 7.874 in and
100 mm 3.937 in long,
respectively, with white
non-glossy paper.
Compact Photoelectric Sensor
PRECAUTIONS FOR PROPER USE
CX-400 SERIES Ver.2
264
Refer to p.1552~ for general precautions.
LASER
SENSORS
All models
PHOTOELECTRIC
SENSORS
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
Mounting
• The tightening
torque should be
0.5 N·m or less.
INDUCTIVE
PROXIMITY
SENSORS
M3
(length 12 mm 0.472 in)
screw with washers Sensor
mounting
bracket
(Optional)
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Others
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
CX-41□ CX-42□ CX-49□ CX-48□
Part description and functions
STATIC
CONTROL
DEVICES
Beam alignment
Stability indicator (Green) (Note 1)
Lights up under the
stable light condition or
the stable dark condition
Operation indicator (Orange) (Note 2)
Lights up when the sensing
output is ON
Sensitivity adjuster (Note 1)
Sensing range becomes
longer when turned.
Operation mode switch (Note 1)
L: Light-ON
D: Dark-ON
Notes: 1) Not incorporated on the emitter.
2) It is the power indicator (green, lights up when the power is ON. )
on the emitter.
Operation mode switch
Operation mode switch
FIBER
SENSORS
Description
Light-ON mode is obtained when the
operation mode switch (thru-beam type incorporate it in the receiver ) is turned fully
clockwise (L side).
Dark-ON mode is obtained when the operation mode switch (thru-beam type incorporate it in the receiver ) is turned fully counterclockwise (D side).
LASER
MARKERS
Thru-beam type
1. Set the operation mode switch to the Light-ON mode position (L
side).
2. Place the emitter and the receiver face to face along a straight
line, move the emitter in the up, down, left and right directions, in
order to determine the range of the light received condition with
the help of the operation indicator (orange). Then, set the emitter at the center of this range.
3. Similarly, adjust for up, down, left and right angular movement of
the emitter.
Sensing object
4. Further, perform the angular adjustment for the receiver also.
5. C heck that the stability indicator
(green) lights up.
6. Choose the operation mode, LightEmitter
ON or Dark-ON, as per your requirement, with the operation mode
switch.
Receiver
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Retroreflective type
1. Set the operation mode switch to the Light-ON mode position (L
side).
2. Placing the sensor and the reflector face to face along a straight
line, move the reflector in the up, down, left and right directions,
in order to determine the range of the light received condition
with the help of the operation indicator (orange). Then, set the
reflector at the center of this range.
3. Similarly, adjust for up, down, left and right angular movement
of the reflector.
4. Further, perform the angular adjustment for the sensor also.
5. Check that the stability indicator
Sensing object
(green) lights up.
6.
C hoose the operation mode,
Light-ON or Dark-ON, as per your
requirement, with the operation
mode switch.
Reflector
Sensor
Power Supply
Built-in
Amplifierseparated
EX-Z
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
265
Compact Photoelectric Sensor
PRECAUTIONS FOR PROPER USE
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Sensitivity adjustment
PRESSURE /
FLOW
SENSORS
A
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
B
A
3
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
A
4
MACHINE
VISION
SYSTEMS
The position at the middle of points
is the optimum sensing position.
and
Note: Use the flathead screwdriver (purchase separately) to turn the adjuster
slowly. Turning with excessive strength will cause damage to the
adjuster.
ENERGY
MANAGEMENT
SOLUTIONS
Light condition
Emitter
Dark condition
Emitter
Receiver
Thru-beam
type
Receiver
Sensing object
UV
CURING
SYSTEMS
Sensor
Reflector
Sensor
Retroreflective
type
Reflector
Sensing object
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
Diffuse
reflective
type
Sensor
EX-20
EX-30
In case of Light-ON
Operation
indicator
Output
EX-40
CX-440
ON
EQ-30
EQ-500
MQ-W
OFF
RX-LS200
RX
RT-610
,
: Lights up,
Glossy surface
• If a shiny object is covered or wrapped with a transparent
film, such as those described below, the retroreflective type
sensor with polarizing filters may not be able to detect it.
In that case, follow the steps given below.
• Can wrapped by clear film
• Aluminum sheet covered by plastic film
• Gold or silver color (specular) label or wrapping paper
Steps
• Tilt the sensor with respect to the sensing object while fitting.
• Reduce the sensitivity.
• Increase the distance between the sensor and the
sensing object.
CX-48□
Retroreflective type sensor for transparent object sensing (CX-48□)
• Optimum sensing is possible when the position of the
transparent sensing object is set at the center of the
sensor and the reflector. If the sensing position is set
near the sensor or the reflector, the sensing may be
unstable. In this case, set the sensing position at the
center of the sensor and the reflector.
Sensor
Sensing
condition
Stable light
receiving
Unstable light
receiving
Unstable dark
receiving
Stable dark
receiving
: Turns OFF
Reflector
Transparent sensing object
Relation between output and indicators
Stability
indicator
Reflector
10° to 30°
Retroreflective type sensor with polarizing filters (CX-491□)
Sensing object
CX-400
EX-10
Sensing
object
L
Sensor
EX-Z
CY-100
Make L sufficiently
long
Example of sensing objects
B
LASER
MARKERS
FA
COMPONENTS
In the dark condition, turn the sensitivity adjuster
further clockwise until the sensor enters the
“Light” state operation and then bring it back to
confirm point where the sensor just returns to
the “Dark” state operation.
If the sensor does not enter the “Light”
state operation even when the sensitivity
adjuster is turned fully clockwise, the
position is point .
Optimum
position
STATIC
CONTROL
DEVICES
Make L, shown in the
diagram, sufficiently long.
2 Install at an angle of 10 to
30 degrees to the sensing
object.
1
In the light received condition, turn the
sensitivity adjuster slowly clockwise and
confirm the point where the sensor
enters the “Light” state operation.
2
SIMPLE
WIRE-SAVING
UNITS
• Please take care of the following points when detecting
materials having a gloss.
Description
Turn the sensitivity adjuster fully
counterclockwise to the minimum
sensitivity position, MIN.
1
INDUCTIVE
PROXIMITY
SENSORS
Retroreflective type sensor (excluding CX-491□)
Sensitivity
adjuster
Step
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
HUMAN
MACHINE
INTERFACES
Refer to p.1552~ for general precautions.
CX-41□ CX-42□ CX-49□ CX-48□
AREA
SENSORS
PLC
CX-400 SERIES Ver.2
In case of Dark-ON
Output
OFF
Operation Stability
indicator
indicator
• When the sensor detects an uneven plastic receptacle or
glass bottle, the received-light amount may differ with the
sensing position or direction. Adjust the sensitivity after
confirming the stable sensing condition by turning the
sensing object, etc.
• When sensing pipe-shaped transparent sensing object,
set it in a standing, not lying, position as shown in Figure
A. The sensor may fail to detect a lying object as shown
in Figure B.
Correct
Incorrect
A
B
ON
Sensor
Reflector
Sensor
Reflector
Compact Photoelectric Sensor
PRECAUTIONS FOR PROPER USE
CX-400 SERIES Ver.2
266
Refer to p.1552~ for general precautions.
FIBER
SENSORS
LASER
SENSORS
CX-41□
Slit mask (Optional)
Interference prevention filter (CX-411□)
PHOTOELECTRIC
SENSORS
• With the slit mask OS-CX-□, the sensor can detect a
small object.
However, the sensing range is reduced when the slit
mask is mounted.
• By mounting the interference prevention filters PF-CX4-□,
two sets of the CX-411□ can be mounted close together.
However, the sensing range is reduced when the
interference prevention filter is mounted.
How to mount
• The filters can be mounted by the same method as for
the slit masks.
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
• Since there are two types of the interference prevention
filter, the two sets of sensors should be fitted with
different types of interference prevention filters, as shown
in the figure below.
The interference prevention does not work even if the
filters are mounted for emitters only, receivers only or the
same model No. of the interference prevention filters are
mounted on both the sets of the sensor.
PRESSURE /
FLOW
SENSORS
1. Insert the fixing hook into the fixing groove.
2. Then, pressing the slit mask against the main unit, insert
the fixing tab into the fixing groove.
Fixing groove
Fixing tab
Removing tab
AREA
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
PF-CX4-H
(Horizontal, Light brown)
WIRE-SAVING
SYSTEMS
Fixing groove
Slit mask
MICRO
PHOTOELECTRIC
SENSORS
MEASUREMENT
SENSORS
Fixing hook
STATIC
CONTROL
DEVICES
How to remove
LASER
MARKERS
1. Insert a screwdriver into the removing tab.
2. Pull forward while lifting the removing tab.
PF-CX4-V
(Vertical, Silver)
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
CX-44□
Mounting
• Care must be taken regarding the sensor mounting
direction with respect to the object’s direction of movement.
Correct
Correct
Sensing
object
Sensing
object
Operation mode switch
Sensing
object
FA
COMPONENTS
Description
Detecting-ON mode is obtained when
the operation mode switch is turned fully
clockwise (L side).
Incorrect
Do not make the
sensor detect an
object in this direction
because it may cause
unstable operation.
• When detecting a specular object (aluminum or copper
foil, etc.) or an object having a glossy surface or coating,
please take care that there are cases when the object
may not be detected due to a change in angle, wrinkles
on the object surface, etc.
• When a specular body is present below the sensor, use the
sensor by tilting it slightly upwards to avoid wrong operation.
Incorrect
Operation mode switch
Not detecting-ON is obtained when the
operation mode switch is turned fully
counterclockwise (D side)
Note: Use the flathead screwdriver (purchase separately) to turn
the operation mode switch slowly. Turning with excessive
strength will cause damage to the adjuster.
• Depending on whether you select the BGS or FGS
function, the output operation changes as follows.
Correct
Sensing range
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
EX-Z
CX-400
CY-100
Setting
distance
EX-10
EX-20
Non-detectable area
EX-30
Specular
face
Tilt
• If a specular body is present in the background, wrong operation
may be caused due to a small change in the angle of the
background body. In that case, install the sensor at an inclination
and confirm the operation with the actual sensing object.
• Take care that there is a non-detectable area right in front
of the sensor.
EX-40
L-ON
ON
OFF
D-ON
ON
OFF
EQ-30
L-ON
ON
OFF
MQ-W
D-ON
ON
OFF
BGS
FGS
CX-440
EQ-500
RX-LS200
RX
RT-610
267
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PRECAUTIONS FOR PROPER USE
SIMPLE
WIRE-SAVING
UNITS
Stability indicator
When using the BGS function
• Since the CX-44□ use a 2-segment photodiode as its
receiving element, and sensing is done based on the
difference in the incident beam angle of the reflected
beam from the sensing object, the output and the
operation indicator (orange) operate according to the
object distance.
Further, the stability indicator (green) shows the margin
to the setting distance.
Sensor
Setting distance
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
EX-Z
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
Description
1
Turn the distance adjuster fully counterclockwise
to the minimum sensing range position.
(CX-441□/443□/444□: 20 mm 0.787 in approx.,
CX-442□: 40 mm 1.575 in approx.)
2
Place an object at the required distance from the
sensor, turn the distance adjuster gradually
clockwise, and find out point A where the sensor
changes to the detecting condition.
3
Remove the object, turn the adjuster clockwise
further until the sensor goes into the detecting
state again. Once it has entered, turn the
distance adjuster backward until the sensor
returns to the non-detecting condition. This
position is designated as point B . When the
sensor does not go into the detecting condition
even if the adjuster is turned fully clockwise, the
position where the adjuster was fully turned is
regarded as the point B .
There may be more than 1 turn between point
A and B , since this sensor incorporates a
5-turn adjuster.
Stability indicator
4
The optimum position to stably detect objects is
the center point between A and B .
OFF (Lights off)
Stable operating condition
Lights up
Stable operating condition
Lights off
Unstable operating condition
BGS/FGS functions
• This sensor incorporates BGS/FGS functions. Select
either BGS or FGS function depending on the positions of
the background and sensing object.
BGS function
• This function is used when the sensing object is
apart from the background.
Sensing
object
FA
COMPONENTS
UV
CURING
SYSTEMS
Step
ON (Lights up)
Output (operation indicator)
(BGS mode, In case of Detection-ON)
ENERGY
MANAGEMENT
SOLUTIONS
MACHINE
VISION
SYSTEMS
Sensing object
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Refer to p.1552~ for general precautions.
CX-44□
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
CX-400 SERIES Ver.2
Turn fully
Optimum
position
• Follow only steps 1 and 2 . Since the sensing point may
change depending on the sensing object, be sure to
check the operation with the actual sensing object.
When using the FGS function
FGS function
• This function is used when the
sensing object contacts the
background or the sensing object is
glossy, etc.
• Please use the FGS function
together with a conveyor or other
background unit.
Distance
adjuster
Background
FIBER
SENSORS
Compact Photoelectric Sensor
• Please use the FGS function together with a conveyor or other background unit.
Step
Sensing
object
1
Background
Distance adjustment
• When this product is used, be sure to carry
out the distance adjustment.
• Since the distance adjuster of this sensor is
a 5-turn adjuster, when the point A and B is
adjusted as explained in the table right, there
may be more than 1 turn between the point A
and B . Therefore, make sure to remember the
turns of both points to find the optimum position.
• Be sure to wire the sensing mode selection
input (Pink / 2) before distance adjustment.
If the wiring is done after the distance
adjustment, the sensing area is changed.
• Turn the distance adjuster gradually and lightly with a
“minus” screwdriver (purchase separately). In order to
protect itself, the distance adjuster idles if turned fully.
If the adjuster is idled when distance adjustment is done,
carry out the adjustment again.
2
Description
Turn the distance adjuster fully clockwise to the
maximum sensing range position.
(CX-441□/443□: 50 mm 1.969 in approx.,
CX-444□: 100 mm 3.937 in approx.,
CX-442□: 300 mm 11.811 in approx.)
In the state where the sensor detects the
background, turn the distance adjuster gradually
counterclockwise, and find out point A where
the sensor changes to the non-detecting
condition.
3
Place an object at the required distance from the
sensor, turn the adjuster counterclockwise further
until the sensor goes into the non-detecting
condition again. Once entered, turn the distance
adjuster backward until the sensor returns to the
detecting condition. This position is designated
as point B . When the sensor does not go into
the non-detecting condition even if the adjuster is
turned fully counterclockwise, the position where
the adjuster was fully turned is regarded as the
point B .
There may be more than 1 turn between point
A and B , since this sensor incorporates a
5-turn adjuster.
4
The optimum position to stably detect objects is
the center point between A and B .
Distance
adjuster
Turn fully
Optimum
position
Others
• Its distance adjuster is mechanically operated. Do not
drop; avoid other shocks.
Compact Photoelectric Sensor
DIMENSIONS (Unit: mm in)
Sensor
Operation indicator (Orange)(Note 2)
Beam
axis
Operation mode switch (Note 1)
20
0.787
3
0.118
ø3.7 ø0.146 cable,
2 m 6.562 ft long (Note 4)
3-core (emitter: 2-core) × 0.2 mm2
insulator diameter: ø1.2 ø0.047
Notes: 1) Not incorporated on the emitter and the basic type sensor.
2) It is the power indicator (green) on the emitter.
3) Not incorporated on the emitter.
4) Basic type: 0.5 m 1.640 ft long
CX-41□-J
Sensor
Sensitivity adjuster (Note 1)
Operation indicator (Orange)(Note 2)
Stability indicator (Green)(Note 1)
Beam
axis
(
Operation indicator (Orange)
2-M3 × 0.5 0.020
thru-hole threads
ø3.7 ø0.146 cable
SENSOR
OPTIONS
M8 connector
11.8
0.465
WIRE-SAVING
SYSTEMS
Center of
sensing
2-M3 × 0.5 0.020
thru-hole threads
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
2.3
(0.091
)
15.5 0.610
25.4
31
1.220 1.000
4
0.157
Beam-emitting
part
PLC
20
0.787
3
0.118
11.2
0.441
STATIC
CONTROL
DEVICES
LASER
MARKERS
7.85 0.309
3.95 0.156
Operation mode switch (Note 1)
MACHINE
VISION
SYSTEMS
ø3.7 ø0.146 cable,
2 m 6.562 ft long (Note 2)
UV
CURING
SYSTEMS
3-core × 0.2 mm2
insulator diameter: ø1.2 ø0.047
300
(11.811
)
Notes: 1) Not incorporated on the emitter.
2) It is the power indicator (green) on the emitter.
SIMPLE
WIRE-SAVING
UNITS
Sensor
Stability indicator (Green)
4 0.157
) M12 connector
44
(1.732
)
PARTICULAR
USE
SENSORS
CX-49□ CX-48□ CX-42□
Beam-receiving
part
2.3
0.091
INDUCTIVE
PROXIMITY
SENSORS
MEASUREMENT
SENSORS
Operation mode switch (Note 1)
15.5 0.610
31
25.4
1.220 1.000
PRESSURE /
FLOW
SENSORS
Notes: 1) Not incorporated on the emitter.
2) It is the power indicator (green) on the emitter.
7.85 0.309
3.95 0.156
20
0.787
3
0.118
11.2
0.441
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
2.3
( 0.091
)
2-M3 × 0.5 0.020
thru-hole threads
Sensitivity adjuster (Note 1)
11.8
0.465
AREA
SENSORS
15.5
31 0.610 25.4
1.220 1.000
35.5
1.398
42.5
1.673
ø9.4
ø0.370
LASER
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
7.85 0.309
3.95 0.156
20
0.787
3
0.118
Beam
axis
FIBER
SENSORS
PHOTOELECTRIC
SENSORS
Operation mode switch (Note 1)
11.2
0.441
2-M3 × 0.5 0.020
thru-hole threads
11.8
0.465
Stability indicator (Green)(Note 1)
2.3
(0.091
)
15.5 0.610
25.4
31
1.220 1.000
Sensor
Operation indicator (Orange)(Note 2)
7.85 0.309
3.95 0.156
Stability indicator (Green)(Note 3)
11.2
0.441
CX-41□-Z
Sensitivity adjuster (Note 1)
11.8
0.465
268
The CAD data can be downloaded from our website.
CX-41□
Sensitivity adjuster (Note 1)
CX-400 SERIES Ver.2
Notes: 1) Not incorporated on the Bacic type sensors.
2) Basic type: 0.5 m 1.640 ft long
Selection
Guide
Amplifier
Built-in
CX-49□-Z CX-48□-Z CX-42□-Z
Sensitivity adjuster
Operation indicator (Orange)
Stability indicator (Green)
15.5 0.610
25.4
35.5 31
1.220
42.5 1.398
1.000
1.673
ø9.4
ø0.370
11.8
0.465
2-M3 × 0.5 0.020
thru-hole threads
CX-49□-J CX-48□-J CX-42□-J
Sensitivity adjuster
7.85 0.309
3.95 0.156
Operation indicator (Orange)
Operation mode switch
20
0.787
3
0.118
11.2
Beam-receiving 0.441
part
Center of
sensing
4
4 0.157
0.157
Beam-emitting
part
Sensor
Stability indicator (Green)
11.2
Beam-receiving 0.441
part
4 0.157
2.3
( 0.091
)
M8 connector
4
0.157
Beam-emitting
part
Center of
sensing
15.5 0.610
31
25.4
1.220 1.000
2-M3 × 0.5 0.020
thru-hole threads
Sensor
11.8
0.465
7.85 0.309
3.95 0.156
Power Supply
Built-in
Amplifierseparated
EX-Z
CX-400
Operation mode switch
20
0.787
3
0.118
CY-100
EX-10
EX-20
EX-30
(
)
2.3
0.091 M12 connector
44
(1.732
)
ø3.7 ø0.146 cable
300
(11.811
)
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
269
FIBER
SENSORS
LASER
SENSORS
Compact Photoelectric Sensor
CX-400 SERIES Ver.2
DIMENSIONS (Unit: mm in)
CX-44□
MICRO
PHOTOELECTRIC
SENSORS
12.5
0.492
Operation indicator (Orange)
Distance adjuster (5-turn)
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
Stability indicator (Green)
11.2
0.441
PRESSURE /
FLOW
SENSORS
PARTICULAR
USE
SENSORS
Beamreceiving part
22
0.866
Beamemitting part
Center of
sensing
2
0.079 2.8
0.110
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
31 25.4
1.220 1.000
22
0.866
Center of
sensing
ø3.7 ø0.146 cable,
2 m 6.562 ft long
4-core × 0.2mm2
insulator diameter:
ø1.2 ø0.047
Beamreceiving part
ø9.4
0.370
RF-220
0.9
0.035
31 25.4
35.5
42.5 1.398 1.220 1.000
1.673
Beamemitting part
M8 connector
2-M3 × 0.5 0.020
thru-hole threads
RF-210
Reflector (Optional)
Reflector (Optional)
33.3
1.311
12.8 0.504
35.3
1.390
M3 nut mounting holes
(for mounting at the back)
Reflector
49.3
59.3 1.941
2.335
2-ø3.6 ø0.142
mounting
holes
25
0.984
8.3
0.327
2-ø4.6 ø0.181
mounting
holes
3.2
0.126
4 0.157
3.3
0.130
40
1.575
Material: Acrylic (Reflector)
ABS (Base)
21
( 0.827
)
8 0.315
5 0.197
MACHINE
VISION
SYSTEMS
11 0.433
34.3
42.31.350
1.665
30
(1.181
)
10 0.394
8.2
0.323
4
0.157
Operation mode switch
20
0.787
3 0.118
2 2.8
0.079 0.110
50.3
1.980
FA
COMPONENTS
UV
CURING
SYSTEMS
Distance adjuster (5-turn)
0.9
0.035
LASER
MARKERS
PLC
12.5
0.492
Operation indicator (Orange)
11.2
0.441
RF-230 Reflector (Accessory for the retroreflective type sensor)
STATIC
CONTROL
DEVICES
Sensor
Stability indicator (Green)
SIMPLE
WIRE-SAVING
UNITS
MEASUREMENT
SENSORS
8.2
0.323
4
0.157
Operation mode switch
20
0.787
3 0.118
2-M3 × 0.5 0.020
thru-hole threads
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
CX-44□-Z
Sensor
PHOTOELECTRIC
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
The CAD data can be downloaded from our website.
3.3
0.130
Base
2-ø3.4 ø0.134 thru-holes
(for mounting at the side)
25
0.984
10
0.394
2-ø3.4 ø0.134 holes,
6 0.236 deep
(for mounting at the back)
8.3
0.327
2-M3 nut mounting holes
(for mounting at the side)
Material: A
crylic (Reflector)
ABS (Base)
Material: Acrylic (Reflector)
ABS (Base)
Two M3 (length 8 mm 0.315 in)
screws with washers and two nuts are attached.
Note: It is not attached with the basic type sensor.
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
RF-11
Amplifierseparated
EX-Z
CX-400
30
1.181
28
1.102
(
)
RF-12
Reflective tape (Optional)
30
1.181
28
1.102
0.7
0.028
(
)
0.7
0.028
Adhesive
tape
(
)
23
25
0.984 0.906
EX-30
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
0.5
0.020
Reflective surface
(Acrylic)
EX-20
EX-40
30
1.181
Reflective tape (Optional)
Rear surface
Effective
reflecting surface
Material: Acrylic
RF-13
30
1.181
( )
8
6
0.315 0.236
CY-100
EX-10
Reflective tape (Optional)
Effective
reflecting surface
Material: Flexible polyvinyl chloride
Adhesive
tape
( pressure-sensitive
)
adhesive
Compact Photoelectric Sensor
DIMENSIONS (Unit: mm in)
CX-400 SERIES Ver.2
The CAD data can be downloaded from our website.
MS-CX2-1
Sensor mounting bracket (Optional)
5
0.197
3.4
0.134
14 0.551
Assembly dimensions
12
0.472
3
0.118
R12
R0.472
8 0.315
22
0.866
15
0.591
7°
t 1.2
t 0.047
0.5
0.020
Mounting drawing with the
receiver of CX-41□
3.4
0.134
3.4
0.134
2-ø3.4 ø0.134 holes
(for RF-210)
R12 R0.472
12
0.472
3
0.118
5
0.197
22
0.866
10 0.394
0.3
(0.012
)
7˚
25.4
1.000
31
1.220
25
0.984
Material: Stainless steel (SUS304)
9.5
0.374
Two M3 (length 12 mm 0.472 in) screws with washers are attached.
42.5
1.673
t 1.2
t 0.047
12.3 0.484
Sensor mounting bracket (Optional)
15.8
0.622
7
0.276
7.8
0.307
22 0.866
14
0.551
R12 R0.472
14°
12
0.472
3.6
(0.142
)
15.8
0.622
8.2
0.323
4
0.157
36
1.417
55
2.165
28
1.102
4.5
0.177
5 0.197
14˚
4.5
0.177
4 0.157
4.5 0.177
t2
t 0.079
4
0.157
R12 R0.472
12
0.472
4.5 0.177
FA
COMPONENTS
15.5
0.610
MACHINE
VISION
SYSTEMS
7 0.276
4.5
0.177
5 0.197
8.2 0.323
18
0.709
0.9
0.035
46
1.811
13
0.512
Power Supply
Built-in
Amplifierseparated
CY-100
EX-10
EX-20
0.9
0.035
6.2
0.244
t 2.5
t 0.098
Two M3 (length 14 mm 0.551 in) screws with washers are attached.
Material: Stainless steel (SUS304)
Selection
Guide
CX-400
29
1.142
40°20°
5.5
0.217 5.5
0.217
25
0.984
UV
CURING
SYSTEMS
EX-Z
R9.5
R0.374
EX-30
18
0.709
13
0.512 11.2
0.441
EX-40
CX-440
EQ-30
EQ-500
25.4
1.000
12.3 0.484
Beam axis
46
1.811
25
0.984
t 2.5
t 0.098
SENSOR
ø25 ø0.984
R25
R0.984
19
29
0.748 1.142
4
0.157
3.4
0.134
ø55 ø2.165
ø39 ø1.535
7
0.276
Mounting drawing
with the receiver
of CX-41□
SENSOR
25
0.984
SENSOR
25
0.984
25.4
1.000
Assembly dimensions
SENSOR
3.4
0.134
HUMAN
MACHINE
INTERFACES
Sensor mounting bracket (Optional)
7°
MEASUREMENT
SENSORS
Amplifier
Built-in
ø55 ø2.165
ø39 ø1.535
6
0.236
14°
SIMPLE
WIRE-SAVING
UNITS
ENERGY
MANAGEMENT
SOLUTIONS
Beam axis
23
15.5
0.906 0.610
MS-CX2-4
19
0.748
SENSOR
OPTIONS
PLC
22
0.866
14
0.551
Two M3 (length 12 mm 0.472 in) screws with washers are attached.
7
0.276
INDUCTIVE
PROXIMITY
SENSORS
LASER
MARKERS
Material: Stainless steel (SUS304)
20°
PRESSURE /
FLOW
SENSORS
Mounting drawing with the
receiver of CX-41□
7.8
0.307
40°
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
STATIC
CONTROL
DEVICES
8-ø3.4 ø0.134
holes
7 0.276
4.5
0.177
t2
t 0.079
AREA
SENSORS
Assembly dimensions
25
10
0.394 0.984
55
2.165
MICRO
PHOTOELECTRIC
SENSORS
WIRE-SAVING
SYSTEMS
MS-CX2-2
14
0.551
LASER
SENSORS
PARTICULAR
USE
SENSORS
Beam axis
20
0.787
12.5 0.492
36
1.417
3.4
0.134 13.6 0.535 25.2
0.992
14˚
FIBER
SENSORS
PHOTOELECTRIC
SENSORS
20
0.787
14°
3.4
25 0.134 R25
42.5 0.984
R0.984
1.673
270
MQ-W
RX-LS200
RX
RT-610
271
FIBER
SENSORS
LASER
SENSORS
Compact Photoelectric Sensor
CX-400 SERIES Ver.2
DIMENSIONS (Unit: mm in)
MS-CX2-5
Sensor mounting bracket (Optional)
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
15
0.591
AREA
SENSORS
t 1.5
t 0.059
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
3.4
0.134
3.4
0.134
3.5
0.138
SENSOR
OPTIONS
5
0.197
SIMPLE
WIRE-SAVING
UNITS
STATIC
CONTROL
DEVICES
8
0.315
Amplifierseparated
EX-Z
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
20
0.787
37
1.457
5
0.197
7.9 0.311
MS-CX-3
Sensor mounting bracket (Optional)
Assembly dimensions
t 1.2
t 0.047
30 1.181
20.5
0.807
10°
R25
R0.984
3.5
0.138 5
3.4
0.197
0.134
3.4
0.134
14
0.551
8
3.4
0.315
0.134
6
0.236
35
25
0.984 1.378
25.2
0.992
13.6
0.535
11.2
0.441
18
0.709
Beam axis
R25
R0.984
10°
15
0.591
3.4
0.134
5
0.197
6
0.236
0.5
0.020
Mounting drawing with the
receiver of CX-41□
8.5
0.335
Two M3 (length 12 mm 0.472 in) screws with washers are attached.
Power Supply
Built-in
7
0.276
20
7 0.787
0.276 37
1.457
Material: Stainless steel (SUS304)
Amplifier
Built-in
R25
R0.984
45
1.772
Two M3 (length 12 mm 0.472 in) screws with washers are attached.
MACHINE
VISION
SYSTEMS
Selection
Guide
7°
Beam axis
Material: Stainless steel (SUS304)
FA
COMPONENTS
UV
CURING
SYSTEMS
25.4
1.000
18.9
0.744 5 0.197
6.5 0.256
PLC
ENERGY
MANAGEMENT
SOLUTIONS
t 1.5
t 0.059
7.9
0.311
LASER
MARKERS
HUMAN
MACHINE
INTERFACES
15
0.591
20.6
26.2 0.811
1.031
18.9
0.744 5 0.197
6.5 0.256
PARTICULAR
USE
SENSORS
MEASUREMENT
SENSORS
Mounting drawing with the
receiver of CX-41□
R19
R 0.748
R25
R0.984
45
1.772
INDUCTIVE
PROXIMITY
SENSORS
Assembly dimensions
25
0.984
19
0.748
19
0.748
7°
PRESSURE /
FLOW
SENSORS
WIRE-SAVING
SYSTEMS
The CAD data can be downloaded from our website.
6
0.236
3.5
0.138
4.8
0.189
18
0.709
6 0.236
3.4
0.134
8
0.315
14
0.551
30
1.181
10°
t 1.2
t 0.047
0.4
0.016
(
8.5
0.335
9 0.354
31
1.220
20
0.787
25.4
1.000
35
1.378
)
Compact Photoelectric Sensor
DIMENSIONS (Unit: mm in)
CX-400 SERIES Ver.2
The CAD data can be downloaded from our website.
MS-RF21-1
Reflector mounting bracket for RF-210 (Optional)
23
0.906
5.5
0.217
23
0.906
ø36
50
ø1.417 1.969
30°
10
0.394
3.2
0.126
ø25
t 1.2 ø0.984
t 0.047
12.5 0.492
10
0.394
R7.5
R0.295
46
1.811
25
0.984
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
20°
PARTICULAR
USE
SENSORS
46
1.811
SENSOR
OPTIONS
25
0.984
13
0.512
SIMPLE
WIRE-SAVING
UNITS
13
0.512
WIRE-SAVING
SYSTEMS
Material: Stainless steel (SUS304)
Two M3 (length 12 mm 0.472 in) screws with washers are attached.
MS-RF22
Reflector mounting bracket for RF-220 (Optional)
Assembly dimensions
25
0.984
4.5
0.177
35
1.378
25
0.984
28.3
19.3 1.114
0.760
4
0.157
35.3
1.390
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
8.3
0.327
FA
COMPONENTS
16 0.630
8 0.315
6 0.236
8-M3 × 0.5 0.020
thru-hole threads
44.3
1.744
t 1.6
t 0.063
MACHINE
VISION
SYSTEMS
34.3
1.350
21
( 0.827
)
27
(1.063
)
20
0.787
STATIC
CONTROL
DEVICES
PLC
10
0.394
11
0.433
10
0.394
MEASUREMENT
SENSORS
LASER
MARKERS
25
0.984
4.5
0.177
44
10 0.394 1.732
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
30°
3.5
0.138
LASER
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
ø36
50
ø1.417 1.969
20°
16
0.630
FIBER
SENSORS
PHOTOELECTRIC
SENSORS
Assembly dimensions
5.5
0.217
272
8 0.315
t 1.6
t 0.063
UV
CURING
SYSTEMS
4
0.157
6
0.236
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Selection
Guide
Two M3 (length 8 mm 0.315 in) screws with washers are attached.
Amplifier
Built-in
MS-RF23
Reflector mounting bracket for RF-230 (Optional)
40
1.575
(
)
3
0.118
Amplifierseparated
Assembly dimensions
4.5
0.177
4.5
0.177
10
0.394 11
0.433
40
1.575
28.3
19.3 1.114
0.760
50.3
1.980
5 0.197
EX-Z
CX-400
10
0.394
50
1.969
40
1.575
CY-100
EX-10
8.3
0.327
EX-20
EX-30
16 0.630
18 0.709
12
0.472
3
(0.118
)
EX-40
15 0.591 61
2.402
35
1.378
t2
t 0.079
7 0.276
26
1.024
28
1.102
(
)
20
0.787
8-M4 × 0.7 0.028 thru-hole threads
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Two M4 (length 10 mm 0.394 in) screws with washers are attached.
Power Supply
Built-in
(
30
(1.181
)
)
7
0.276
CX-440
49.3
1.941
61.3
2.413
37
1.457
10
0.394
40
1.575
5
0.197
EQ-30
t2
t 0.079
EQ-500
MQ-W
RX-LS200
RX
RT-610