0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FX-301P-F

FX-301P-F

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SENSOR THROUGH-BEAM PNP 24VDC

  • 详情介绍
  • 数据手册
  • 价格&库存
FX-301P-F 数据手册
157 FIBER SENSORS Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F Related Information ■■General terms and conditions.............. F-3 Glossary of terms / General precautions....P.1549~ / P.1552~ ■■Selection guide………………………… P.3~ ■■Korea's S-mark.............................. P.1602 LASER SENSORS PHOTOELECTRIC SENSORS Recognition MICRO PHOTOELECTRIC SENSORS AREA SENSORS Certified (FX-301-F only) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS FX-301-F7 The FX-301-F7 (Note 1) dedicated for the leak detection fiber FD-F71 and the FX-301-F dedicated for the liquid detection fiber FT-F93 are available. Optimal setting is possible with easy operation. Threshold value will be set automatically to -20 % of the incident light intensity during the teaching to steadily detect the leak. It is also possible to change the threshold value to -15 % or -30 %. Incident light intensity (During teaching) Note: The FX-301-F can be also used by setting it to leak detection mode. However, the functions are different from the FX-301-F7 dedicated for the leak detection fiber, so it is recommended to use the FX-301-F7 when using the leak detection fiber. Leak detection fiber FD-F71 Liquid detection fiber FT-F93 -15 % -20 % -30 % Threshold follow-up function Incident light intensity is checked at regular time interval (10 min.), and threshold value is reset automatically. Other Products Dedicated amplifier for the leak detection fiber FX-301-F7 Dedicated amplifier for the liquid detection fiber FX-301-F FX2 FX-CH Automatic sensitivity setting Sets the optimal threshold value Fiber Amplifiers FX-CH2 Timer For use with leak detection or liquid detection fiber only Fibers FX-311 FX-301-F7/ FX-301-F FX-11A Light intensity monitor Easy operation even for beginners! Optimum settings can be realized with simple operations Selection Guide FX-300 PNP output type available Incident light intensity LASER MARKERS panasonic.net/id/pidsx/global Easy maintenance, as main and sub units are identical Both main and sub units utilize the same amplifier body. This feature allows for easy mounting in the side-by-side configuration. The main and sub unit Sub cable functions are distinguished only by the proper use of 3-core main cable and the 1-core sub cable. Main cable Moreover, by utilizing the same body for both main and sub units, inventory management and maintenance is simplified. Incident light intensity STATIC CONTROL DEVICES (At the time of factory shipment) Threshold value FX-301-F7 Incident light intensity (Current value) Threshold value Time *Function is set to OFF at the time of factory shipment. Flashing function incorporated When the leak detection fiber is connected (F7 mode), if a leak is detected, you will recognize which fiber detects the leak at a single glance because the emitter will start flashing. Long life and stable operational settings due to the newly developed emitting element The newly developed “four-chemical emitting element” used for FX-301-F7 / FX-301-F can suppress the secular change of the light emitting element to minimum, allowing stable detection for long period of time. Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F Easy to operate with individual / collective teaching mode Individual teaching mode (TEACH) Optimal threshold value is set automatically on FX-301-F7 just by setting the MODE indicator to “TEACH” and pressing the jog switch. The threshold value is set after selecting the liquid detection fiber for FX-301-F. 158 FIBER SENSORS Collective teaching mode (ALL) Teaching is performed collectively for all the connected amplifiers with an optical communication function when the MODE indicator is set to “ALL”. Each amplifier will be set with an optimal threshold value. At the same time, other setting in the master unit will be copied to the slave unit. LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Communication direction Collective teaching mode is possible for 16 units max. SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS LEAK DETECTION FIBER (FD-F71) MEASUREMENT SENSORS Low profile liquid detection fiber with high chemical resistance STATIC CONTROL DEVICES Labor-saving design • Because all you need to install is one screw, one-touch mounting of the fiber head is possible. • Replacement parts even for resetting after a leak are unnecessary. • Because the fiber head is simply designed, wiping off leaks is rendered easy. SEMI S2 compliant! Superb explosion resistance / chemical resistance Leak detection fiber cannot be used in combination with the FX-100/300/311/410 series. Explosion resistance is enhanced by adopting the fiber method (SEMI S2 compliant). The head unit made of fluorocarbon polymers also has superb chemical resistance. Stable detection performance The unique effect of capillarity enables reliable detection of small leaks and viscous liquids. PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Amplifier Built-in Leak Detection Sensor High-speed detection even a little liquid leak EX-F70 SERIES EX-F60 SERIES FD-F71 LASER MARKERS Selection Guide Fibers Fiber Amplifiers Other Products FX-300 P.877~ Capillarity effect Fiber head Liquid FX-311 FX-301-F7/ FX-301-F FX-11A FX2 FX-CH2 FX-CH Leakage pan Compact, space-saving This slim (10 mm 0.394 in) side-mounting fiber head is especially good for use in confined spaces. 159 FIBER SENSORS LASER SENSORS Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F LIQUID DETECTION FIBER (PIPE-MOUNTABLE) (FT-F93) Stably detect the liquid inside the pipe! Stable design that doesn’t permit liquid-absent or sensor errors • When liquid is present, its effect on the lens causes light to focus and enter. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Liquid present SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Liquid absent PRESSURE / FLOW SENSORS SEMI S2 compliant! INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Leak detection fiber cannot be used in combination with the FX-100/300/311/410 series. Because there is no electric circuitry in the fiber head, it boasts excellent explosion resistance. MEASUREMENT SENSORS Easy to use and reliable detection LASER MARKERS PLC • When abnormalities such as a severed or removed fiber or a cutoff cable occur, light does not enter and the sensor will output the same as “liquid-absent”. When the fiber cable is severed Superior explosion resistance compatible to SEMI S2 WIRE-SAVING SYSTEMS STATIC CONTROL DEVICES Beam-receiving signal Low Beam-receiving signal High Beam-receiving signal Zero Severed! Even when the shape and thickness of the pipe vary, this fiber head uses a method where the beam axis follows the diameter of the pipe, and so when compared to conventional methods, the shape and thickness of the pipe have no influence over the performance of this fiber head. Reliable detection not affected by bubbles or droplets Latest optical fiber techniques have solved problems caused by bubbles, droplets or liquid leakage that arise in conventional pipe-mountable fiber heads. HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide ORDER GUIDE Amplifiers Quick-connection cable is not supplied with the amplifier. Please order it separately. Type Leak detection fiber only Appearance Model No. Emitting element FX-301-F7 NPN output Output NPN open-collector transistor Red LED PNP output FX-301P-F7 PNP open-collector transistor NPN output FX-301-F NPN open-collector transistor Fibers Fiber Amplifiers Other Products Liquid detection fiber only FX-300 Red LED FX-301P-F PNP output PNP open-collector transistor FX-311 FX-301-F7/ FX-301-F FX-11A FX2 FX-CH2 FX-CH Quick-connection cables Quick-connection cable is not supplied with the amplifier. Please order it separately. Type Main cable (3-core) Sub cable (1-core) Model No. CN-73-C1 Description CN-73-C5 CN-71-C1 Length: 1 m 3.281 ft CN-71-C2 CN-71-C5 • CN-73-C□ Length: 1 m 3.281 ft 0.2 mm2 3-core cabtyre cable, with Length: 2 m 6.562 ft connector on one end Cable outer diameter: ø3.3 mm ø0.130 in Length: 5 m 16.404 ft CN-73-C2 Main cable 0.2 mm2 1-core cabtyre cable, with Length: 2 m 6.562 ft connector on one end Cable outer diameter: ø3.3 mm ø0.130 in Length: 5 m 16.404 ft Sub cable • CN-71-C□ FX-301-F7 FX-301-F Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only 160 ORDER GUIDE FIBER SENSORS LASER SENSORS End plates End plates are not supplied with the amplifier. Please order it separately when the amplifiers are mounted in cascade. Appearance Model No. MS-DIN-E PHOTOELECTRIC SENSORS Description MICRO PHOTOELECTRIC SENSORS When amplifiers are mounted in cascade, or when an amplifier moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides. Make sure to use end plates when cascading multiple amplifiers together. AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS 2 pcs. per set Fiber heads Bending durability Designation Shape of fiber head (mm in) : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius: R4 mm R0.157 in or less) features. INDUCTIVE PROXIMITY SENSORS : Refers to a fiber which possesses unbreakable bending-resistant feature (bending radius: R10 mm R0.394 in, reciprocating bending: 180°). PARTICULAR USE SENSORS Model No. Bending Fiber cable length radius : (mm) Free-cut SEMI S2 compliant Leak detection fiber W20 × H30 × D10 W0.787 × H1.181 × D0.394 Bending durability FD-F71 R4 5m 16.405 ft SEMI S2 compliant W23 × H20 × D17 Liquid detection fiber W0.906 × H0.787 × D0.669 PRESSURE / FLOW SENSORS Bending durability FT-F93 Protective tube R20 Fiber R2 2m 6.562 ft Protection Ambient temp. Dimensions Description Liquid leak detection Leak absent: Beam received, Leak present: Beam not received Dedicated amplifier for the leak detection fiber : FX-301-F7 Applicable pipe diameter: Outer dia. ø3 to ø10 mm ø0.118 to ø0.394 in Transparent pipe PFA (fluorine resin) or equivalently transparent pipe, wall thickness 0.3 to 1.0 mm 0.012 to 0.039 in Liquid absent: Beam not received, Liquid present: Beam received Dedicated amplifier for the liquid detection fiber : FX-301-F IP67 −20 to +60 °C −4 to +140 °F P.68 SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES IP40 −40 to +60 °C −40 to +140 °F LASER MARKERS P.58 PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS About the handling of the fiber cable length changed product The type with fiber cable length changed is prepared as a semi-custom product with fast response. Please contact the sales regarding the model name, standard price, and delivery. • Applicable fiber cable length: Up to 25 m 82.021 ft, in 1 m 3.281 ft intervals. • Applicable protective tube length: Up to 10 m 32.808 ft, in 0.5 m 1.641 ft intervals. FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Accessories FX-CT2 (Fiber cutter) FX-AT4 (Attachment for ø1 mm ø0.039 in fiber, black) MS-FD-F7-1 (SUS mounting bracket for FD-F71) MS-FD-F7-2 (PVC mounting bracket for FD-F71) • FX-CT2 SENSOR OPTIONS • FX-AT4 Selection Guide • MS-FD-F7-1 (SUS mounting bracket for FD-F71) • MS-FD-F7-2 (PVC mounting bracket for FD-F71) Fibers Fiber Amplifiers Other Products FX-300 FX-311 OPTIONS Designation Amplifier mounting bracket Fiber sensor amplifier protection seal FX-301-F7/ FX-301-F Model No. Description MS-DIN-2 Mounting bracket for amplifier FX-MB1 10 sets of 2 communication window seals and 1 connector seal Communication window seal: It prevents malfunction due to transmission signal from another amplifier, as well as, prevents effect on another amplifier. Connector seal: It prevents contact of any metal, etc., with the pins of the quickconnection cable. Amplifier mounting bracket • MS-DIN-2 FX-11A FX2 FX-CH2 FX-CH Fiber sensor amplifier protection seal • FX-MB1 Communication window seal Connector seal 161 FIBER SENSORS LASER SENSORS Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. FX-301(P)-F7  FX-301(P)-F Amplifier PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS FX-301(P)-F7: Automatic follow-up function indicator FX-301(P)-F: Model indicator (Green) (Note 1) PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Beamemitting part PARTICULAR USE SENSORS SENSOR OPTIONS MODE key Jog switch 3 0.118 64.5 2.539 27.8 Communication 1.094 window 7 0.276 30.5 1.201 7 0.276 10.5 0.413 7 0.276 3 0.118 WIRE-SAVING SYSTEMS 13.5 0.531 3.95 0.156 Suitable for 35 mm 1.378 in width DIN rail 36.5 1.437 Note: Above figure is an external dimension drawing of the FX-301(P)-F7. Shape of the indicator for FX-301(P)-F is little different. CN-73-C□ Main cable (Optional) PLC CN-71-C□ Sub cable (Optional) L L HUMAN MACHINE INTERFACES ø3.3 ø0.130 cable ENERGY MANAGEMENT SOLUTIONS 14 0.551 2.9 0.114 2.54 0.100 FA COMPONENTS ø3.3 ø0.130 cable 10 0.394 6 0.236 2.54 0.100 2.65 0.104 14 0.551 2.54 0.100 10.5 0.413 MACHINE VISION SYSTEMS UV CURING SYSTEMS 0.7 0.028 Digital display (Red) 3 0.118 10 0.394 Beamreceiving part SIMPLE WIRE-SAVING UNITS LASER MARKERS 12 0.472 Operation indicator (Orange) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS STATIC CONTROL DEVICES 48.2 1.898 26.3 1.035 2.5 0.098 8.3 0.327 AREA SENSORS MEASUREMENT SENSORS FX-301-F7 FX-301-F 2.9 0.114 10 0.394 6 0.236 10.5 0.413 0.2 0.008 7 0.276 10 0.394 13.6 0.535 3 0.118 2.54 0.100 2.65 0.104 7.2 0.283 0.2 0.008 7 0.276 10 0.394 13.6 0.535 • Length L 3 0.118 7.2 0.283 • Length L Selection Guide Model No. Length L Model No. Length L Fibers CN-73-C1 1,000 39.390 CN-71-C1 1,000 39.390 Fiber Amplifiers CN-73-C2 2,000 78.740 Other Products CN-71-C2 2,000 78.740 CN-73-C5 5,000 196.850 CN-71-C5 5,000 196.850 FX-300 FX-311 MS-DIN-2 Amplifier mounting bracket (Optional) FX-301-F7/ FX-301-F FX-11A FX2 FX-CH2 21.6 0.850 16 0.630 5.2 0.205 10 0.394 3.2 0.126 FX-CH 0.4 0.016 7.5 0.295 2 0.079 35 1.378 5.2 0.205 End plates (Optional) 2.75 0.108 3.2 0.126 8.5 0.335 MS-DIN-E M3 (length 18 mm 0.709 in) pan head screws 3 0.118 5 0.197 15 0.591 60 2.362 2-ø3.2 ø0.126 holes Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) 5.6 M3 square nut 0.220 24.7 0.972 2 ø1.8 ø0.071 0.079 4.2 0.165 3 0.118 t1 t 0.039 1.6 0.063 32 1.260 27 1.063 Material: Polycarbonate 4 0.157 Suitable for 35 mm 1.378 in width DIN rail Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only DIMENSIONS (Unit: mm in) FX-301-F7 FX-301-F The CAD data can be downloaded from our website. FD-F71 Free-cut FT-F93 Free-cut Fiber Emission indicator 5,000 196.850 3,000 118.110 30 1.181 7.8 0.307 10 20 0.394 0.787 [PFA(Fluorine resin)] 10 0.394 17.7 12.2 0.480 0.697 2-ø1 ø0.039 Beam-emitting side (Gray) Beam-receiving side (Black) ø0.25 ø0.010 fiber core × 4 (PMMA) Outer sheath ø1 ø0.039 (Polyethylene) (ø3.1) (ø0.122) Protective tube [PFA(Fluorine resin)] 22 0.866 6.2 0.244 5.5 0.217 11 0.433 20 0.787 12 0.472 2,000 78.740 1,000 2-ø1 ø0.039 39.370 7.2 0.283 23 0.906 10.3 0.406 5.5 0.217 6 0.236 Enclosure (ABS) 6 0.236 17 0.669 9 0.354 SUS mounting bracket mounting diagram 0.3 0.012 10 15 0.394 0.591 PVC mounting bracket (MS-FD-F7-2) 15.5 10.5 0.413 0.610 MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS SIMPLE WIRE-SAVING UNITS FD-F71 SUS mounting bracket WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES PVC mounting bracket mounting diagram LASER MARKERS 30 1.181 4 0.157 11 Welding part 0.433 Material: PVC ø3.1 ø0.122 PHOTOELECTRIC SENSORS SENSOR OPTIONS 0.3 0.012 5.7 0.224 Beam-receiving side (Black) ø0.25 ø0.010 × 4 fiber core (PMMA) Sheath ø1 ø0.039 (Polyethylene) ø3.1 ø0.122 Protective tube [PFA(Fluorine resin)] LASER SENSORS PARTICULAR USE SENSORS 30 1.181 11.5 ø4.2 ø0.165 thru-holes 0.453 Material: [PFA(Fluorine resin)] Material: Stainless steel (SUS316) 10.3 0.406 12 0.472 10 0.394 Beam-emitting side (Gray) FIBER SENSORS INDUCTIVE PROXIMITY SENSORS SUS mounting bracket (MS-FD-F7-1) 17 0.669 10 0.394 162 10 0.394 25 0.984 PLC FD-F71 11.5 0.453 10 0.394 PVC mounting bracket FT-F93 HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS FD-F71 Selection Guide Fibers Fiber Amplifiers Other Products FX-300 FX-311 FX-301-F7/ FX-301-F FX-11A FX2 FX-CH2 FX-CH
FX-301P-F
1. 物料型号:文档中提到了多个型号,例如CX-411, CX-412, CX-413, CX-491, CX-493, CX-481, CX-482, CX-424, CX-421, CX-422, CX-423, CX-441, CX-443, CX-444, CX-442等。

2. 器件简介:文档介绍了CX-400系列的紧凑型光电传感器,它们具有内置放大器、环境友好、低功耗等特点,适用于多种工业应用。

3. 引脚分配:文档中提供了不同型号传感器的引脚分配图和说明,例如NPN和PNP输出类型的I/O电路图。

4. 参数特性:文档列出了传感器的各种参数特性,包括感应范围、电源电压、电流消耗、输出类型、响应时间、环境温度和湿度等。

5. 功能详解:文档详细解释了传感器的功能,如自动背景抑制功能(BGS/FGS)、抗干扰能力、极性保护、感应模式选择输入等。

6. 应用信息:文档提供了传感器的应用示例,如检测不到位的胶带送料盒、在多尘环境中检测物体、检测透明玻璃瓶、检测小型药片等。

7. 封装信息:文档包含了传感器的尺寸图和安装支架的详细信息,以及可选配件如反光带、传感器安装支架等。
FX-301P-F 价格&库存

很抱歉,暂时无法提供与“FX-301P-F”相匹配的价格&库存,您可以联系我们找货

免费人工找货