0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FX2-A3R

FX2-A3R

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SENSOR FIBER NPN 12-24VDC

  • 数据手册
  • 价格&库存
FX2-A3R 数据手册
197 FIBER SENSORS High-speed / LED Sensing Fiber Sensor FX2 SERIES Related Information ■ General terms and conditions........... P.1 ■ Sensor selection guide ....................P.11~ / P.61~ LASER SENSORS PHOTOELECTRIC SENSORS UL Recognition (FX2-A3R only) MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY COMPONENTS PRESSURE SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS High-speed response time: 15 μs (FX2-A3R) LED sensing type (FX2-A3R-LED) is also available SPECIFICATIONS Fibers Type STATIC CONTROL DEVICES LASER MARKERS Item Model No. Sensing range Min. sensing object (Note 4) Selection Guide Fibers FT / FD / FR Fiber Sensor Amplifiers FX-100 FX-300 FX-410 FX-311 FX-11A FX-301-F Other Products Hysteresis Fiber cable length For high-speed type Reflective type FT-SFM2L FD-G500 FT-FM2 (Note 5) 4 mm 0.158 in (Convergent point: 1.5 mm 0.059 in) (Note 3) Using a combination of FT-FM2 and FX-LE1, umber colored LED having a luminous intensity of 2 mcd or more (peak wavelength: 590 nm 0.023 mil) can be detected. (Setting distance: 10 mm 0.394 in, with no extraneous light) ø2 mm 0.079 in opaque object ø0.05 mm 0.002 in copper wire – – 10 % or less of operation distance (Note 3) – 2 m 0.079 ft free-cut 500 mm 19.685 in 2 m 0.079 ft free-cut 50 mm 1.969 in (Note 2) Allowable bending radius Ambient temperature For LED sensing type Thru-beam type with lens R25 mm 0.984 in or more –40 to +70 °C –40 to +158 °F (No dew condensation or icing allowed), Storage: –40 to +70 °C –40 to +158 °F Material Fiber core: Acrylic, Sheath: Polyethylene Fiber head dimensions ø2.5 × 8 mm ø0.098 × 0.315 in M4 × 25 mm 0.984 in M4 × 15 mm 0.984 in Accessories FX-CT2 (fiber cutter): 1 pc. Fiber attachment: 1 set (Note 6) M4 Nut: 2 pcs. Toothed lock washer: 1 pc. M4 Nut: 4 pcs., Toothed lock washer: 2 pcs. FX-CT2 (fiber cutter): 1 pc. Fiber attachment: 1 set (Note 6) Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 3) The sensing range and the hysteresis of reflecfive type are specified for white non-glossy paper (15 × 15 mm 0.591 × 0.591 in) as the object. 4) The minimum sensing object size of reflecfive type is the value for type at maximum sensitivity. Also, note that the corresponding setting distance is different from the rated sensing distance. 5) Two fibers make up one set for the FT-FM2. However, when using it together with the LED sensing type (FX2-A3R-LED), only one fiber is used. 6) The fiber attachment is not used with the FX2 series. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com High-speed / LED Sensing Fiber Sensor SPECIFICATIONS FX2 SERIES 198 The CAD data in the dimensions can be downloaded from the SUNX website: hm FIBER SENSORS LASER SENSORS Amplifiers Type Item High-speed type Model No. LED sensing type FX2-A3R Supply voltage 12 V DC ± 10 % Power consumption FX2-A3R-LED Ripple P-P 10 % or less 12 to 24 V DC ± 10 % 55 mA or less Ripple P-P 10 % or less 20 mA or less NPN transistor universal • Maximum sink current: 100 mA • Residual voltage: 1.0 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) Output Output operation Selectable either Light-ON or Dark-ON, by the control input Response time In light state: 15 μs or less, In dark state: 35 μs or less In light state: 50 ms or less, In dark state: 100 ms or less Operation indicator Red LED (lights up when the output is ON) Sensitivity adjuster 3-turn endless potentiometer Protection IP66 (IEC) (Note 2) (Refer to p.984 for details of standards.) Ambient temperature IP62 (IEC) (Refer to p.984 for details of standards.) –10 to +50 °C –14 to +122 °F (FX2-A3R-LED: 0 to +50°C +32 to +122 °F) (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F 500 ℓx – Emitting element: Red LED (Peak emission wavelength: 660 nm 0.026 mil, non-modulation) Receiving element: Photodiode (Peak wavelength: 590 nm 0.023 mil) Ambient illuminance Emitting / Receiving element Material AREA SENSORS SAFETY COMPONENTS PRESSURE SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS WIRESAVING SYSTEMS MEASUREMENT SENSORS Polycarbonate Weight PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Net weight: 120 g approx. �imensions W14 × H30 × D56 mm W0.551 × H1.181 × D2.205 in Accessories MS-FX-1 (Amplifier mounting bracket): 1 set, Adjusting screwdriver: 1 pc., Adjusting knob: 1 pc. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) This is the value when the combination fiber has been attached. However, the value is IP65 when combined with the free-cut type fiber. 3) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. STATIC CONTROL DEVICES LASER MARKERS OPTIONS Designation Expansion lens Model No. FX-LE1 Description Applicable fibers FT-FM2 Selection Guide • Sensing range (FX2-A3R-LED + FT-FM2): 10 mm 0.394 in • Ambient temperature: –60 to +350 °C –76 to +662 °F • Ambient humidity: 35 to 85 % RH Fibers FT / FD / FR Fiber Sensor Amplifiers Pinpoint spot lens FX-MR1 FD-G500 FX-100 Enables detection of minute objects or small marks. • Spot diameter: ø0.5 mm ø0.020 in approx. • Distance to focal point: 6 ± 1 mm 0.236 ± 0.039 in • Ambient temperature: –60 to +300 °C –76 to +572 °F • Ambient humidity: 35 to 85 % RH FX-300 FX-410 FX-311 FX-11A • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. • Since FX2-A3R-LED is un-modulated and high sensitivity type, take sufficient care against extraneous light. Do not install at places where extraneous light may be directly incident on the receiver. In such cases use a light blocking plate. FX-301-F Refer to p.986 ~ for general precautions and p.105 for precautions of fibers. • If slight difference between 110 light and dark levels is to be sensed, supply the power 100 15 min. before commencing 90 the sensing. When power is just supplied, the sensitivity 0 5 10 15 20 Time after power on (sensing distance) is (min.) approx. 10 % higher. • The sensing sensitivity is affected by the amplifier’s ambient temperature fluctuation. Avoid use of the amplifier where the temperature fluctuation is large and the sensing tolerance is small. • Do not use during the initial transient time (FX2-A3R-LED: 0.5 sec., FX2-A3R: 30 ms) after the power supply is switched on. Sensitivity (%) PRECAUTIONS FOR PROPER USE Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Other Products
FX2-A3R 价格&库存

很抱歉,暂时无法提供与“FX2-A3R”相匹配的价格&库存,您可以联系我们找货

免费人工找货
FX2-A3R
  •  国内价格 香港价格
  • 1+2456.756351+304.75949
  • 10+2233.4284510+277.05576

库存:5