DC 2-wire Cylindrical Inductive Proximity Sensor
Amplifier Built-in
2-wire type Oil resistant Metal embedding
possible
available
GXL
INDUCTIVE
PROXIMITY SENSORS
GX-U/FU SERIES
GX-U/FU
GL-18H/18HL
GL-N12
Amplifier Built-in
GL-8/8U
GL-6
High performance
&
ease of use
Conforming to
EMC Directive
Robust in tightening
Compact size: "5.4 mm "0.213 in
Long sensing range
The tightening torque has been improved to approx. four times greater
than that of conventional models
because of its thick case. As the
sensor can be securely tightened, it
does not get loose due to vibration or
shock.
GX-5SU(B) is just 5.4 mm 0.213in in
diameter, the smallest in existing DC
two-wire sensors. It saves you space.
The GX-U series features 1.6 times
longer sensing range than conventional
models. As it can be mounted at a sufficient distance from the object, there is no
fear of the sensor and the object colliding.
Conventional
GX-18M(B) model
19.6 N•m or less 4 times approx.
GX-18MU(B)
GX-12MLU(B)
"5.4 mm
"0.213 in
8 mm
0.315 in
80 N•m or less
s
1.6
GA-10/GH
Amplifier-separated
GX
GX-N
GX-12ML(B)
time
Conventional model
5 mm
0.197 in
2-color indicator
Simple wiring
Spatter-resistant type available
The normally open type is equipped
with a 2-color indicator.
The normally closed type has the
operation indicator instead.
The operation is easily observable
from any direction because the entire
sensor tail lights up.
The wiring cost is considerably
reduced as it is DC 2-wire type.
Further, each of GX-12MU(B),
GX-18MU(B), GX-30MU(B) is available as a pigtailed model (300 mm
11.811 in long cable with attached
connector) that makes replacement
easy and quick.
As the enclosure is entirely coated by
fluorine resin, the sensor can be safely
used at a place where welding spatters
fly around.
Both the pigtail cable and the mating
cable are also spatter-resistant.
(
)
722
APPLICATIONS
Controlling depth of drilling
Positioning object at welding station
(GX-FU-J only)
By detecting the
dog, the sensor
decides the depth
of the drilled hole.
It can reliably detect even
aluminum pallets because
of its long sensing range.
It can be safely used even where
welding sparks (spatter) fly around.
GL-6
GXL
Detecting traveling aluminum pallets
INDUCTIVE
PROXIMITY SENSORS
GX-U/FU
GL-8/8U
ORDER GUIDE
Standard type
"5.4
"0.213
1.5 mm 0.059 in
30
1.181
Maximum operation distance
(0 to 1.2 mm 0 to 0.047 in)
Stable sensing range
2 mm 0.079 in
M8
30
1.181
(0 to 1.6 mm 0 to 0.063 in)
3 mm 0.118 in
Threaded type
Shielded type
Sensing range (Note)
M12
40.5
1.594
(0 to 2.4 mm 0 to 0.094 in)
7 mm 0.276 in
Model No.
Output
Output operation
GX-5SU
Normally open
GX-5SUB
Normally closed
GX-8MU
Normally open
GX-8MUB
Normally closed
GX-12MU
Normally open
GX-12MUB
Normally closed
GX-18MU
Normally open
GX-18MUB
Normally closed
GX-U/FU
Appearance (mm in)
Amplifier Built-in
GL-18H/18HL
GL-N12
Non-threaded type
Type
M18
GX-30MU
44.5
1.752
GX-30MUB
(0 to 8 mm 0 to 0.315 in)
4 mm 0.157 in
M8
30
1.181
(0 to 3.2 mm 0 to 0.126 in)
Threaded type
Non-shielded type
8 mm 0.315 in
M12
40.5
1.594
(0 to 6.4 mm 0 to 0.252 in)
15 mm 0.591 in
Non-contact
DC 2-wire type
Normally open
Normally closed
GX-8MLU
Normally open
GX-8MLUB
Normally closed
GX-12MLU
Normally open
GX-12MLUB
Normally closed
GX-18MLU
Normally open
GX-18MLUB
Normally closed
GX-30MLU
Normally open
GX-30MLUB
Normally closed
GX-N
10 mm 0.394 in
M30
GX
(0 to 5.6 mm 0 to 0.220 in)
Amplifier-separated
GA-10/GH
41.5
1.634
M18
41.5
1.634
(0 to 12 mm 0 to 0.472 in)
22 mm 0.866 in
M30
44.5
1.752
(0 to 17.6 mm 0 to 0.693 in)
Note: The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if
there is an ambient temperature drift and/or supply voltage fluctuation.
723
INDUCTIVE
PROXIMITY SENSORS
GX-U/FU
ORDER GUIDE
5 m 16.404 ft cable length type and pigtailed type
5 m 16.404 ft cable length type (standard : 2 m 6.562 ft) and pigtailed type (standard: cable type) are also available.
Type
GX-N
Threaded type
Threaded type
Shielded type
Non-shielded type
GX-U/FU
GL-18H/18HL
GL-N12
Amplifier Built-in
GL-8/8U
GL-6
Non-threaded type
GXL
• Table of Model Nos.
Standard
5 m 16.404 ft cable length type
Pigtailed type (Note)
GX-5SU
GX-5SU-C5
GX-5SUB
GX-5SUB-C5
GX-8MU
GX-8MU-C5
GX-8MUB
GX-8MUB-C5
GX-12MU
GX-12MU-C5
GX-12MU-J
GX-12MUB
GX-12MUB-C5
GX-12MUB-J
GX-18MU
GX-18MU-C5
GX-18MU-J
GX-18MUB
GX-18MUB-C5
GX-18MUB-J
GX-30MU
GX-30MU-C5
GX-30MU-J
GX-30MUB
GX-30MUB-C5
GX-30MUB-J
GX-8MLU
GX-8MLU-C5
GX-8MLUB
GX-8MLUB-C5
GX-12MLU
GX-12MLU-C5
GX-12MLU-J
GX-12MLUB
GX-12MLUB-C5
GX-12MLUB-J
GX-18MLU
GX-18MLU-C5
GX-18MLU-J
GX-18MLUB
GX-18MLUB-C5
GX-18MLUB-J
GX-30MLU
GX-30MLU-C5
GX-30MLU-J
GX-30MLUB
GX-30MLUB-C5
GX-30MLUB-J
Note: Please order the suitable mating cable separately for pigtailed type.
• Mating cable
• CN-22G-C2, CN-22G-C5
Model No.
Description
GX
"14 mm "0.551 in
CN-22G-C2
GA-10/GH
Amplifier-separated
CN-22G-C5
724
Length: 2 m
6.562 ft
Length: 5 m
16.404 ft
0.3 mm2 2-core flame-resistant, spatter-resistant cable
(outer dia "3.6 mm "0.142 in) with connector at one end
300 mm
11.811 in
approx.
Mating cable
CN-22G-C2
(length 2 m 6.562 ft)
CN-22G-C5
(length 5 m 16.404 ft)
ORDER GUIDE
Spatter-resistant type
Sensing range (Note)
3 mm 0.118 in
Threaded type
Shielded type
M12
40.5
1.594
Maximum operation distance
(0 to 2.4 mm 0 to 0.094 in)
Model No.
Output
Output operation
Non-contact
DC 2-wire type
Normally open
GXL
Appearance (mm in)
GX-F12MU-J
Stable sensing range
7 mm 0.276 in
GX-F18MU-J
M18
41.5
1.634
(0 to 5.6 mm 0 to 0.220 in)
GL-6
Type
INDUCTIVE
PROXIMITY SENSORS
GX-U/FU
10 mm 0.394 in
GX-F30MU-J
M30
GL-8/8U
(0 to 8 mm 0 to 0.315 in)
44.5
1.752
Note: The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if
there is an ambient temperature drift and/or supply voltage fluctuation.
• Mating cable
Description
"14 mm "0.551 in
CN-22G-C2
CN-22G-C5
Length: 2 m
6.562 ft
Length: 5 m
16.404 ft
0.3 mm2 2-core flame-resistant, spatter-resistant cable
(outer dia "3.6 mm "0.142 in) with connector at one end
300 mm
11.811 in
approx.
Mating cable
CN-22G-C2
(length 2 m 6.562 ft)
CN-22G-C5
(length 5 m 16.404 ft)
OPTIONS
For GX-5SU(B)
MS-H12
For GX-12MU(B)
MS-H18
For GX-18MU(B)
MS-H30
For GX-30MU(B)
The sensor is easily mounted with this bracket.
It protects the sensing surface from welding sparks
(spatter), etc.
Protection cover
GX-N
MS-SS5
• MS-SS5
• MS-H12
• MS-H18
• MS-H30
GX
Sensor mounting
bracket
Protection cover
Description
Amplifier-separated
GA-10/GH
Model No.
GX-U/FU
Sensor mounting bracket
Designation
Amplifier Built-in
GL-18H/18HL
GL-N12
• CN-22G-C2, CN-22G-C5
Model No.
725
SPECIFICATIONS
Standard type
Type
Model No.
INDUCTIVE
PROXIMITY SENSORS
GXL
GL-6
GX-U/FU
Item
Normally open
Shielded type
Non-threaded type
GX-5SU
Non-shielded type
Threaded type
GX-8MU
GX-12MU
Threaded type
GX-18MU
GX-30MU
Normally closed GX-5SUB GX-8MUB GX-12MUB GX-18MUB GX-30MUB GX-8MLUB GX-12MLUB GX-18MLUB GX-30MLUB
Max. operation distance (Note 1) 1.5 mm 0.059 in10% 2 mm 0.079 in10%
3 mm 0.118 in10%
7 mm 0.276 in10% 10 mm 0.394 in10% 4 mm 0.157 in10%
0 to 1.2 mm 0 to 0.047 in 0 to 1.6 mm 0 to 0.063 in 0 to 2.4 mm 0 to 0.094 in 0 to 5.6 mm 0 to 0.220 in 0 to 8 mm 0 to 0.315 in 0 to 3.2 mm 0 to 0.126 in 0 to 6.4 mm 0 to 0.252 in 0 to 12 mm 0 to 0.472 in 0 to 17.6 mm 0 to 0.693 in
Standard sensing object
Iron sheet 66t 1 mm Iron sheet 88t 1 mm Iron sheet 1212t 1 mm Iron sheet 1818t 1mm Iron sheet 3030t 1 mm Iron sheet 2020t 1 mm Iron sheet 3030t 1 mm Iron sheet 5050t 1 mm Iron sheet 7070t 1 mm
0.2360.236t 0.039 in 0.3150.315t 0.039 in 0.4720.472t 0.039 in 0.7090.709t 0.039 in 1.1811.181t 0.039 in 0.7870.787t 0.039 in 1.1811.181t 0.039 in 1.9691.969t 0.039 in 2.7562.756t 0.039 in
20 % or less of operation distance
Hysteresis
10
12 to 24 V DC
15 % Ripple P-P 10 % or less
Supply voltage
0.8 mA or less
Non-contact DC 2-wire type
• Load current: 3 to 70 mA (Note 3) • Residual voltage: 3 V or less (Note 4)
GL-8/8U
Output
DC-12 or DC-13
Utilization category
Incorporated
Short-circuit protection
Max. response frequency
1.7 kHz
1.2 kHz
Environmental resistance
GL-18H/18HL
GL-N12
Amplifier Built-in
500 Hz
350 Hz
1 kHz
650 Hz
350 Hz
220 Hz
Normally open type: Lights up in green under stable sensing condition, lights up in orange under unstable sensing condition
2-color indicator
Pollution degree
3 (Industrial environment)
Protection
IP67 (IEC), IP67g (JEM)
Ambient temperature
25 to70 °C 13 to158 °F, Storage:30 to80 °C 22 to176 °F
Ambient humidity
45 to 85 % RH, Storage: 35 to 95 % RH
EMC
EN 50081-2, EN 50082-2, EN 60947-5-2
Voltage withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Shock resistance
GX-U/FU
1.2 kHz
Normally closed type: Orange LED (lights up when the output is ON)
Operation indicator
Sensing range Temperature characteristics
variation
Voltage characteristics
Over ambient temperature range25 to70°C 13 to158 °F: within10 % of sensing range at 20 °C 68°F
Within2 % for 10 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated) [However, Stainless steel (SUS303) for GX-5SU(B), GX-8MU(B) and GX-8MLU(B)]
Sensing part: Nylon [However, polyalylate for GX-5SU(B)], Indicator part: Nylon [excluding GX-5SU(B)]
Material
0.3 mm2 [0.15 mm2 for GX-5SU(B), GX-8MU(B) and GX-8MLU(B)] 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Cable
GX-N
8 mm 0.315 in10% 15 mm 0.591 in10% 22 mm 0.866 in10%
Stable sensing range (Note 1)
Current consumption (Note 2)
Cable extension
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Weight (Note 5)
20 g approx. 30 g approx. 55 g approx. 95 g approx.
Accessories
GX
GX-8MLU GX-12MLU GX-18MLU GX-30MLU
220 g approx.
30 g approx. 55 g approx. 95 g approx.
220 g approx.
Nut: 2 pcs., Toothed lock washer: 1 pc.
Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
Notes: 2) It is the leakage current when the output is in the OFF state.
Notes: 3) The maximum load current varies depending on the ambient temperature. Refer to ‘I/O CIRCUIT AND WIRING DIAGRAMS’ on p.727l for more details.
Notes: 4) When the cable is extended, the residual voltage becomes larger.
Notes: 5) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
GA-10/GH
Amplifier-separated
Spatter-resistant type
Shielded type
Type
Item
Model
No.
Material
Cable
Cable extension
Weight (Note)
Accessories
Normally open
Threaded type
GX-F12MU-J
GX-F18MU-J
GX-F30MU-J
Enclosure: Brass (Fluorine resin coated), Sensing part: Polyalylate (Fluorine resin coated), Indicator part: Polyalylate
0.3 mm2 2-core spatter-resistant cable, 0.3 m 0.984 ft long with round type connector
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
35 g approx.
75 g approx.
200 g approx.
Nut: 2 pcs. (Fluorine resin coated), Toothed lock washer: 1 pc. (Fluorine resin coated)
The specifications other than the above-mentioned are identical to that of the standard type (GX-12MU, GX-18MU, GX-30MU).
Note: The given weight includes the weight of two nuts and one toothed lock washer.
726
I/O CIRCUIT AND WIRING DIAGRAMS
GX-U(B)
I/O circuit diagram
Wiring diagram
Bleeder resistance
Sensor circuit
ZD
Bleeder resistance
Brown
Load
3 to 70 mA in ON state (Note)
0.8 mA in OFF state
3 V in ON state
Users’ circuit
12 to 24 V DC
10
15 %
Blue
Load
Conditions for the load
Symbols ... ZD: Surge absorption zener diode
Tr : PNP output transistor
Note: The maximum load current varies depending on the ambient
temperature.
1) The load should not be actuated by the leakage current (0.8 mA) in
the OFF state.
2) The load should be actuated by (supply voltage – 3 V) in the ON state.
3) The current in the ON state should be between 3 to 70 mA DC.
In case the current is less than 3 mA, connect a bleeder resistance
in parallel to the load so that a current of 3 mA, or more, flows.
[
]
70
35
Amplifier Built-in
GL-18H/18HL
GL-N12
Max. load current (mA)
12 to 24 V DC
10 %
15
Load
(Blue) 0 V
Internal circuit
Load
GL-6
GXL
(Brown) Output
GL-8/8U
Color code
Tr
INDUCTIVE
PROXIMITY SENSORS
GX-U/FU
3
25
13
Ambient temperature (°C °F)
55
131
70
158
I/O circuit diagram
GX-U/FU
GX-U(B)-J
Wiring diagram
Color code of mating cable
Color code of mating cable
Bleeder resistance
Bleeder resistance
3 to 70 mA in ON state (Note)
0.8 mA in OFF state
3 V in ON state
(Black) 0 V
Internal circuit
Blue
Users’ circuit
[
]
Connector pin position
GX-U-J (Normally open)
70
1
2
Not connected
35
3
Ambient temperature (°C °F)
Load
1) The load should not be actuated by the leakage current (0.8 mA) in
the OFF state.
2) The load should be actuated by (supply voltage – 3 V) in the ON state.
3) The current in the ON state should be between 3 to 70 mA DC.
In case the current is less than 3 mA, connect a bleeder resistance
in parallel to the load so that a current of 3 mA, or more, flows.
Note: The maximum load current varies depending on the ambient
temperature.
25
13
12 to 24 V DC
10%
15
Conditions for the load
Load
Symbols ... ZD: Surge absorption zener diode
Tr : PNP output transistor
Max. load current (mA)
12 to 24 V DC
10 %
15
GX-N
ZD
Load
55
131
70
158
3
Not connected
V
4
0V
GX-UB-J (Normally closed)
1
2
0V
3
Not connected
V
4
Not connected
Color code of
mating cable /
Connector pin No.
(Brown / 1) Output
White
Not connected
Blue
(Black / 4) 0 V
Color code of
mating cable /
Connector pin No.
(Brown / 1) Output
Black
Not connected
Blue
(White / 2) 0 V
727
GX
Tr
Brown
Load
Amplifier-separated
GA-10/GH
Sensor circuit
(Brown)
Output
INDUCTIVE
PROXIMITY SENSORS
GX-U/FU
I/O CIRCUIT AND WIRING DIAGRAMS
GX-FU-J
I/O circuit diagram
GXL
GL-6
Sensor circuit
(Brown / 1) Output
Tr
ZD
Bleeder resistance
Brown / 1
3 to 70 mA in ON state (Note)
0.8 mA in OFF state
3 V in ON state
12 to 24 V DC
10 %
15
Blue / 4
Load
Conditions for the load
1) The load should not be actuated by the leakage current (0.8 mA) in
the OFF state.
2) The load should be actuated by (supply voltage – 3 V) in the ON state.
3) The current in the ON state should be between 3 to 70 mA DC.
In case the current is less than 3 mA, connect a bleeder resistance
in parallel to the load so that a current of 3 mA, or more, flows.
Users’ circuit
[
Note: The maximum load current varies depending on the ambient
temperature.
]
Connector pin position
70
1
2
Not connected
35
V
3
25
13
Ambient temperature (°C °F)
55
131
70
158
3
Not connected
4
0V
SENSING CHARACTERISTICS (TYPICAL)
GX-5SU
GX-5SUB
2
0.079
Correlation between sensing object size and sensing range
Standard sensing object Iron sheet
66t 1 mm 0.2360.236t 0.039 in
#
L
1
0.039
GX
0
2
0.079
Sensing range L (mm in)
Sensing field
Sensing object
aa mm aa in
2
t 1 mm t 0.039 in
0.079 L
Iron
1
0.039
As the sensing object size becomes smaller than
the standard size (iron sheet 6 6 t 1 mm
0.236 0.236 t 0.039 in), the sensing range
shortens as shown in the left figure.
Stainless steel
(SUS304)
Brass
Aluminum
0
1
0
1
2
0.039
0.039
0.079
Center
Left
Right
Operating point ?(mm in)
5
10
15
0.197
0.394
0.591
Sensing object side
length a (mm in)
20
0.787
GX-8MU
GX-8MUB
Setting distance L (mm in)
2
0.079
1
0.039
0
4
0.157
728
Standard sensing
object Iron sheet
88t 1 mm
0.3150.315
t 0.039 in
#
L
2
0
2
4
0.079
0.079
0.157
Center
Left
Right
Operating point ?(mm in)
Correlation between sensing object size and sensing range
As the sensing object size becomes smaller than
Sensing object aa mm aa in
t 1 mm t 0.039 in
the standard size (iron sheet 8 8 t 1 mm
L
Iron
2
0.315 0.315 t 0.039 in), the sensing range
0.079
shortens as shown in the left figure.
Sensing range L (mm in)
Sensing field
12 to 24 V DC
10
15 %
Symbols ... ZD: Surge absorption zener diode
Tr : PNP output transistor
Max. load current (mA)
Load
Load
(Blue / 4) 0 V
Setting distance L (mm in)
GL-8/8U
GL-18H/18HL
GL-N12
Amplifier Built-in
GX-U/FU
GX-N
Color code of mating cable /
Connector pin No.
Load
Internal circuit
GA-10/GH
Amplifier-separated
Wiring diagram
Color code of
mating cable /
Connector pin No. Bleeder resistance
Stainless steel
(SUS304)
1
0.039
Brass
Aluminum
0
5
10
15
0.197
0.394
0.591
Sensing object side
length a (mm in)
20
0.787
SENSING CHARACTERISTICS (TYPICAL)
GX-12MU GX-12MUB
GX-F12MU-J
2
0.079
0
4
0.157
L
As the sensing object size becomes smaller than
the standard size (iron sheet 1212t 1 mm
0.472 0.472 t 0.039 in), the sensing range
shortens as shown in the left figure.
GXL
4
0.157
Sensing object aa mm aa in
t 1 mm t 0.039 in
Iron
Stainless steel
(SUS304)
2
0.079
Brass
Aluminum
GL-6
Standard sensing object Iron sheet
1212t 1 mm 0.4720.472t 0.039 mm
#
L
2
0
2
4
0.079
0.079
0.157
Center
Left
Right
Operating point #(mm in)
0
10
20
30
0.394
0.787
1.181
Sensing object side
length a (mm in)
40
1.575
GL-8/8U
4
0.157
Correlation between sensing object size and sensing range
Sensing range L (mm in)
Setting distance L (mm in)
Sensing field
GX-18MU GX-18MUB
GX-F18MU-J
Setting distance L (mm in)
5
0.197
0
20
0.787
Correlation between sensing object size and sensing range
As the sensing object size becomes smaller than
Sensing object aa mm aa in
the standard size (iron sheet 1818t 1 mm
t 1 mm t 0.039 in
L
10
0.709 0.709 t 0.039 in), the sensing range
0.394
shortens as shown in the left figure.
10
0
10
20
0.394
0.394
0.787
Center
Left
Right
Operating point #(mm in)
Amplifier Built-in
GL-18H/18HL
GL-N12
Standard sensing object Iron sheet
1818t 1 mm 0.7090.709t 0.039 in
#
L
Sensing range L (mm in)
Sensing field
10
0.394
Iron
Stainless steel
(SUS304)
5
0.197
Brass
Aluminum
0
10
20
30
0.394
0.787
1.181
Sensing object side
length a (mm in)
40
1.575
0
20
0.787
10
0
10
20
0.394
0.394
0.787
Center
Left
Right
Operating point #(mm in)
5
0.197
L
0
GX-N
5
0.197
(SUS304)
Brass
Sensing object aa mm aa in Aluminum
t 1 mm t 0.039 in
20
40
60
0.787
1.575
2.362
Sensing object side
length a (mm in)
80
3.150
GX
Standard sensing object Iron sheet
3030t 1 mm 1.1811.181t 0.039 in
#
L
Correlation between sensing object size and sensing range
As the sensing object size becomes smaller than
the standard size (iron sheet 3030t 1 mm
Iron
10
1.181 1.181 t 0.039 in), the sensing range
0.394
shortens as shown in the left figure.
Stainless steel
Sensing range L (mm in)
Setting distance L (mm in)
Sensing field
GX-U/FU
GX-30MU GX-30MUB
GX-F30MU-J
10
0.394
GX-8MLU
GX-8MLUB
4
0.157
0
10
0.394
Standard sensing
object Iron sheet
2020t 1 mm
0.7870.787
t 0.039 in
#
L
5
0
5
10
0.197
0.197
0.394
Center
Left
Right
Operating point ?(mm in)
Amplifier-separated
GA-10/GH
Correlation between sensing object size and sensing range
As the sensing object size becomes smaller than
Sensing object aa mm aa in
t 1 mm t 0.039 in
the standard size (iron sheet 2020t 1 mm
L
Iron
4
0.787 0.787 t 0.039 in), the sensing range
0.157
shortens as shown in the left figure.
Sensing range L (mm in)
Setting distance L (mm in)
Sensing field
2
0.079
INDUCTIVE
PROXIMITY SENSORS
GX-U/FU
Stainless steel
(SUS304)
2
0.079
0
Brass
Aluminum
10
20
30
0.394
0.787
1.181
Sensing object side
length a (mm in)
40
1.575
729
SENSING CHARACTERISTICS (TYPICAL)
GX-12MLU
GX-12MLUB
5
0.197
Correlation between sensing object size and sensing range
As the sensing object size becomes smaller than
Sensing object aa mm aa in
the standard size (iron sheet 3030t 1 mm
t 1 mm t 0.039 in
L
10
1.181 1.181 t 0.039 in), the sensing range
0.394
shortens as shown in the left figure.
Iron
Sensing range L (mm in)
Setting distance L (mm in)
Standard sensing object Iron sheet
3030t 1 mm 1.1811.181t 0.039 mm
#
L
10
0.394
0
20
0.787
10
0
10
20
0.394
0.394
0.787
Center
Left
Right
Operating point #(mm in)
Stainless steel
(SUS304)
5
0.197
0
Brass
Aluminum
20
40
60
0.787
1.575
2.362
Sensing object side
length a (mm in)
80
3.150
GX-18MLU
GX-18MLUB
20
0.787
Standard sensing object Iron sheet
5050t 1 mm 1.9691.969t 0.039 in
#
L
10
0.394
0
20
0.787
Correlation between sensing object size and sensing range
As the sensing object size becomes smaller than
Sensing object aa mm aa in
the standard size (iron sheet 5050t 1 mm
t 1 mm t 0.039 in
L
20
1.969 1.969 t 0.039 in), the sensing range
0.787
shortens as shown in the left figure.
Sensing range L (mm in)
Setting distance L (mm in)
Sensing field
Iron
10
0.394
10
0
10
20
0.394
0.394
0.787
Center
Left
Right
Operating point #(mm in)
0
Stainless steel
(SUS304)
Brass
Aluminum
20
40
60
0.787
1.575
2.362
Sensing object side
length a (mm in)
80
3.150
GX-30MLU
GX-30MLUB
Sensing field
Setting distance L (mm in)
GX-N
GX-U/FU
GL-18H/18HL
GL-N12
Amplifier Built-in
GL-8/8U
GL-6
GXL
Sensing field
Correlation between sensing object size and sensing range
As the sensing object size becomes smaller than
Iron
the standard size (iron sheet 7070t 1 mm
20
2.756 2.756 t 0.039 in), the sensing range
0.787
Stainless steel
shortens as shown in the left figure.
(SUS304)
20
0.787
10
0.394
GA-10/GH
Amplifier-separated
GX
0
20
0.787
730
Standard sensing object
Iron sheet 7070t 1 mm
2.7562.756t 0.039 in
#
L
10
0
10
20
0.394
0.394
0.787
Center
Left
Right
Operating point #(mm in)
Sensing range L (mm in)
INDUCTIVE
PROXIMITY SENSORS
GX-U/FU
10
0.394
0
Brass
Aluminum
Sensing object aa mm aa in
t
1
mm
t
0.039
in
L
20
40
60
0.787
1.575
2.362
Sensing object side
length a (mm in)
80
3.150
PRECAUTIONS FOR PROPER USE
Refer to p.1152l for general precautions.
This product is not a safety sensor. Its use is not
intended or designed to protect life and prevent body
injury or property damage from dangerous parts of
machinery. It is a normal object detection sensor.
Distance from surrounding metal
• As metal around the sensor may affect the sensing
performance, pay attention to the following points.
Mounting
• The tightening torque should be under the value given
below.
• The surrounding metal will affect the sensing performance. Keep the minimum distance specified in the
table below.
Model No. A (mm in) B (mm in) Tightening torque
0.78 Nm
B
• Do not fix on the operation indicator or opposite to it.
Operation
indicator
Operation
indicator
Operation
indicator
Set
screw
GX-18MU(B)
GX-F18MU-J
20 0.787
GX-30MU(B)
GX-F30MU-J
40 1.575
GX-8MLU(B)
8 0.315
GX-12MLU(B)
22 0.866
GX-18MLU(B)
45 1.772
GX-30MLU(B)
75 2.953
GL-6
8 0.315
Embedding of the sensor in metal
Mounting with nut
C
Attached toothed
lock washer
C
• Sensing range may decrease if the sensor is completely
embedded in metal. Especially for the non-threaded type
and the non-shielded type, keep the minimum distance
specified in the table below.
Attached toothed
lock washer
Model No.
E
Mounting plate
F
Mounting plate
E (mm in)
F (mm in)
GX-5SU(B)
"12 "0.472
3 0.118
GX-8MLU(B)
"24 "0.945
12 0.472
GX-12MLU(B)
"50 "1.969
15 0.591
GX-18MLU(B)
"75 "2.953
25 0.984
GX-30MLU(B)
"105 "4.134
30 1.181
Metal
Model No.
Dimension C (mm in)
Tightening torque
3 to 10.3 0.118 to 0.406
5.9 N m
10.3 0.406 or more
11.8 N m
GX-8MU(B)
GX-12MU(B)
GX-F12MU-J
3.5 to 13.5 0.138 to 0.531
10 N m
13.5 0.531 or more
20 N m
GX-18MU(B)
GX-F18MU-J
4 to 18 0.157 to 0.709
45 N m
18 0.709 or more
80 N m
GX-30MU(B)
GX-F30MU-J
5 to 21 0.197 to 0.827
80 N m
21 0.827 or more
180 N m
GX-8MLU(B)
12 0.472 or more
11.8 N m
GX-12MLU(B)
15 0.591 or more
20 N m
GX-18MLU(B)
25 0.984 or more
80 N m
GX-30MLU(B)
30 1.181 or more
180 N m
Note: With the non-shielded type, the sensing range may vary depending
on the position of the nuts.
Mutual interference
• When two or more sensors are installed in parallel or face
to face, keep the minimum separation distance specified
below to avoid mutual interference.
Face to face mounting
G
Parallel mounting
Note: Mount such that the nuts do not protrude from the threaded portion.
Model No.
G (mm in) H (mm in)
GX-5SU(B)
19 0.748
14 0.551
GX-8MU(B)
20 0.787
15 0.591
GX-12MU(B)
GX-F12MU-J
35 1.378
20 0.787
GX-18MU(B)
GX-F18MU-J
70 2.756
45 1.772
GX-30MU(B)
GX-F30MU-J
115 4.528
70 2.756
GX-8MLU(B)
60 2.362
45 1.772
GX-12MLU(B)
145 5.709
95 3.740
H
GX-18MLU(B)
250 9.843 165 6.496
GX-30MLU(B)
350 13.780 250 9.843
731
GX-N
3 0.118
4.5 0.177
GX-12MU(B)
GX-F12MU-J
GX
5 to 30
0.197 to 1.181
GX-8MU(B)
Amplifier-separated
GA-10/GH
GX-5SU(B)
D
GL-8/8U
4.5 0.177
GX-U/FU
Background metal
• Tighten with the cup-point of a set screw (M4 or less).
D (mm in)
GX-5SU(B)
Amplifier Built-in
GL-18H/18HL
GL-N12
Model No.
GXL
Influence of surrounding metal
Mounting with a set screw
Set screw
(M4 or less)
A
INDUCTIVE
PROXIMITY SENSORS
GX-U/FU
PRECAUTIONS FOR PROPER USE
Sensing range
• The sensing range is specified for the standard sensing
object. With a non-ferrous metal, the sensing range is
obtained by multiplying with the correction coefficient
specified below.
Correction coefficient
Metal
Iron
GX-U/FU
GL-18H/18HL
GL-N12
Amplifier Built-in
GL-8/8U
GL-6
Model No.
GX-N
Refer to p.1152l for general precautions.
Stainless steel
(SUS304)
Brass
Aluminum
Wiring
• The sensor must be connected to a power supply via a
load. If the sensor is connected to a power supply without a
load, the short-circuit protection makes the sensor inoperable.
(The output stays in the OFF state and the indicator does
not light up.) In this case, rectify by connecting the power
supply via a load. Now, the sensor becomes operable.
Further, take care that if the power supply is connected with
reverse polarity without a load, the sensor will get damaged.
GX-5SU(B)
1
0.63 approx. 0.32 approx. 0.30 approx.
GX-8MU(B)
1
0.59 approx. 0.32 approx. 0.29 approx.
GX-12MU(B)
GX-F12MU-J
1
0.75 approx. 0.51 approx. 0.49 approx.
GX-18MU(B)
GX-F18MU-J
1
0.75 approx. 0.50 approx. 0.48 approx.
GX-30MU(B)
GX-F30MU-J
1
0.69 approx. 0.44 approx. 0.42 approx.
GX-8MLU(B)
1
0.64 approx. 0.38 approx. 0.38 approx.
GX-12MLU(B)
1
0.67 approx. 0.44 approx. 0.43 approx.
Series connection (AND circuit)
Parallel connection (OR circuit)
When all sensors are in the ON state,
the load voltage VRL is given by:
VRL VCCn3 (V)
When all sensors are in the OFF state,
the load leakage current lcc is given by:
Blue lead wire
Brown lead wire
DC
power
supply
DC
power
supply
Brown lead wire
GX-18MLU(B)
1
0.68 approx. 0.45 approx. 0.43 approx.
GX-30MLU(B)
1
0.67 approx. 0.44 approx. 0.43 approx.
Note: The sensing range also changes if the sensing object is plated.
Protection cover (Optional)
• It protects the sensing surface from welding sparks (spatter), etc.
Mounting method
Protection cover
Sensor
Material: Fluorine resin
Vcc: supply voltage
(24 V DC max.)
n: number of sensors
GX-12MU(B)
MS-H18
GX-18MU(B)
MS-H30
Note: The output is generated normally even if the indicator
does not light up properly.
Others
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
Note: The load current in the ON state
is given by:
IL
Vcc3 V
(mA)
Load resistance
The load current must be
3 mAn h IL h 70 mA
(n: number of sensors turned ON)
Brown lead wire
Load
Brown lead wire
Load
VRL
Blue lead wire
Blue
lead wire
VCC
Brown
lead wire
GX-30MU(B)
Note: Mount the protection cover so that there is no gap between it and the
sensing surface.
lcc n0.8 (mA) (n: number of sensors)
Make sure that the load can work properly.
Make sure that the load can work
properly at this voltage.
Model No. Applicable model No.
MS-H12
Blue lead wire
• For series connection (AND circuit) or parallel connection
(OR circuit) of sensors, take care of the following.
ICC
(IL)
Brown
lead wire
Blue lead wire
VCC
Blue lead wire
• The residual voltage of the sensor is 3 V. Before connecting a relay as the load, take care of its actuation voltage.
(Some 12 V relays may not be usable.)
Relay
INDUCTIVE
PROXIMITY SENSORS
GXL
GX-U/FU
• When the sensor is mounted on a moving base, stress
should not be applied to the sensor cable joint.
Relay actuation
voltage:
VR h123 V
h9 V
VR Relay actuation
voltage
Brown lead wire
Vs 3 V Residual voltage
when the sensor
is in the ON state
12 V DC
power supply
Blue lead wire
Lights OFF
Output operation
level
LED lights
up in green
Max.
operation
distance
Switched OFF
Stress
Setting distance
Stress
Switched ON
GA-10/GH
Amplifier-separated
GX
2-color indicator (Normally open type only)
• When the sensing object is in the stable sensing range,
the LED lights up in green, and when the sensing object is
in the unstable sensing range, the LED lights up in
orange. While the LED lights up in green, the sensing is
performed stably without being affected by temperature
drifts or voltage fluctuations.
0
Output operation
2-color indicator operation
732
Unstable range
LED lights up
in orange
DIMENSIONS (Unit: mm in)
GX-5SU
GX-5SUB
The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.co.jp/
GX-8MU
GX-8MUB
Sensor
Sensor
INDUCTIVE
PROXIMITY SENSORS
GX-U/FU
"21
"0.827
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
GX-30MU
GX-30MUB
Sensor
Indicator part
1.3
0.051
5
0.197 2
39.5
0.079
1.555
M301.5 0.059
36
1.417
"43
"1.693
GX-12MLU
GX-12MLUB
Toothed lock washer
(Internally toothed)
24
0.945
Indicator part
1.3
0.051
5
0.197 2
39.5
0.079
12 1.555
0.472 M301.5 0.059
"3.6 "0.142 cable,
2 m 6.562 ft long
Toothed lock washer
(Internally toothed)
"6.8
"0.268
"2.9 "0.114 cable, 2 m 6.562 ft long
5
0.197 2
36.5
0.079
1.437
M181 0.039
"5.5
"0.217
"10.4
"0.409
"15.2
"0.598
4
0.157
2-color indicator
(Orange, green) (Note)
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
Indicator part
1.3
0.051
"3.6 "0.142 cable,
2 m 6.562 ft long
2-color indicator
Toothed lock washer
(Orange, green) (Note)
(Internally toothed)
GL-6
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
GX-12MU-J GX-12MUB-J
Sensor
GX-F12MU-J
5
35.5 0.197
1.398
2
M121 0.039
0.079
17
0.669
"5.5
"0.217
"10.4
"0.409
5
0.236
3
0.118
2-color indicator
(Orange, green) (Note)
Sensor
10
0.394
2-color indicator
(Orange, green) (Note)
Sensor
"43 "1.693
10
0.394
20
0.787
"29 "1.142
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
"26.6
"1.047
M81 0.039
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
"3.6 "0.142 cable,
2 m 6.562 ft long
3.5
0.138
36
1.417
Indicator part
GX-18MLU
GX-18MLUB
Sensor
"21 "0.827
Sensor
2-color indicator
(Orange, green) (Note)
Toothed lock washer
(Internally toothed)
Indicator part
5
0.197 2
35.5
1.3
1.398
0.051
0.079
M121 0.039
"5.5
"0.217
"10.4
"0.409
GX-30MLU
GX-30MLUB
GX-8MLU
GX-8MLUB
"6.5
"15
"0.256
6
"0.591 Toothed
0.236
lock washer
(Internally toothed)
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
"10.2
"0.402
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
"3.6 "0.142 cable,
2 m 6.562 ft long
5
0.197
"3.6 "0.142 cable,
2 m 6.562 ft long
2-color indicator
Toothed lock washer
(Orange, green) (Note)
(Internally toothed)
4
0.157
12
0.472
"5.5
"0.217
"10.4
"0.409
7
0.276
"29
"1.142
"3.6 "0.142 cable,
2 m 6.562 ft long
2-color indicator
Toothed lock washer
(Orange, green) (Note)
(Internally toothed)
3.5
0.138
5
Indicator part
0.197 2
36.5
1.3
0.079
1.437
0.051
M181 0.039
"5.5
"0.217
"10.4
"0.409
24
0.945
GL-8/8U
Indicator part
1.3
0.051
2
0.079
"5.5
"0.217
"10.4
"0.409
Sensor
GX-U/FU
5
0.197
35.5
1.398
M121 0.039
17
0.669
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
GX-18MU
GX-18MUB
Sensor
3
"2.9 "0.114 cable, 2 m 6.562 ft long
0.118
GX-N
GX-12MU
GX-12MUB
2-color indicator
"6.8 (Orange, green) (Note)
"0.268
GX
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
10
0.394
20
0.787
"15 Toothed
"0.591 lock washer
(Internally toothed)
"2.9 "0.114 cable, 2 m 6.562 ft long
4
0.157
16.5
0.650
17
0.669
M81 0.039
Amplifier Built-in
GL-18H/18HL
GL-N12
12
0.472
"21
"0.827
3.5
0.138
Indicator part
(300)
(11.811)
44
1.732
1.3
0.051
"14
"0.551
M12
connector
"3.6 "0.142 cable
2-color
indicator
Toothed lock washer
(Orange, green)
(Internally toothed)
"10.4 "5.5
"0.409 "0.217
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
733
Amplifier-separated
GA-10/GH
"5.4
"0.213
2-color indicator
(Orange, green) (Note)
GXL
Indicator part
30
1.181
1.5
0.059
INDUCTIVE
PROXIMITY SENSORS
GX-U/FU
DIMENSIONS (Unit: mm in)
GX-18MU-J GX-18MUB-J
Sensor
GX-F18MU-J
GXL
GL-6
"29
"1.142
4
0.157
"10.4
"0.409
GL-8/8U
Indicator part
1.3
0.051
"14
"0.551
M12
connector
"3.6 "0.142 cable
7
0.276
"10.2
"0.402
5
(300)
35.5 0.197
(11.811)
1.398
2
44
0.079
M121 0.039
1.732
"5.5
"0.217
"10.4
"0.409
3.5
0.138
Indicator part
1.3
0.051
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
36
1.417
2-color
indicator
(Orange, green)
Toothed lock washer
(Internally toothed)
Sensor
5
(300)
36.5 0.197
1.437
(11.811)
2
0.079
M181 0.039
"5.5
"0.217
1.3
0.051
44
1.732
"14
"0.551
M12
connector
"10.4
"0.409
"29 "1.142
Indicator part
"3.6 "0.142 cable
4
0.157
Toothed lock washer
(Internally toothed)
2-color indicator
(Orange, green)
(Note)
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
Indicator part
1.3
0.051
"14
"0.551
"26.6
"1.047
M12
connector
"3.6 "0.142 cable
Toothed lock washer
(Internally toothed)
"10.4
"0.409
"43"1.693
5
0.197
2-color indicator
(Orange, green)
(Note)
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
MS-SS5
GX-N
Sensor mounting bracket for GX-5SU(B) (Optional)
2-"3.5 "0.138
mounting holes
8.3
0.327
MS-H12 MS-H18
MS-H30
0
GX
Material: Nylon 66
734
Symbol
A
A
0.70.2
0
0.0280.008
Model No.
BC
4 0.157
4
0.157
Protection cover (Optional)
Thickness of
front face
18
10
0.709 0.394
GA-10/GH
Amplifier-separated
M12
connector
"3.6 "0.142 cable
Sensor
5
(300)
39.5 0.197
1.555
(11.811) 44
2
0.079
1.732
M301.5 0.059
"5.5
"0.217
12
0.472
10
0.394
"15.2
"0.598
2-color indicator
(Orange, green) (Note)
"3.6 "0.142 cable
Toothed lock washer
(Internally toothed)
GX-30MLU
GX-30MLUB
24
0.945
"14
"0.551
M12
connector
"10.4
"0.409
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
GX-18MLU-J
GX-18MLUB-J
Sensor
"21 "0.827
"43
"1.693
5
0.197
2-color
indicator
(Orange, green)
Note: Normally closed type has an operation indicator (orange) instead of
the 2-color indicator.
17
0.669
Indicator part
1.3
0.051
5
(300)
39.5 0.197
(11.811)
1.555
2
44
M301.5 0.059
0.079
1.732
"5.5
"0.217
36
1.417
"14
"0.551
Toothed lock washer
(Internally toothed)
GX-12MLU-J
GX-12MLUB-J
GL-18H/18HL
GL-N12
Amplifier Built-in
GX-30MU-J GX-30MUB-J
Sensor
GX-F30MU-J
5
(300)
36.5 0.197
(11.811)
1.437
2
44
M181 0.039
0.079
1.732
"5.5
"0.217
24
0.945
GX-U/FU
The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.co.jp/
8
0.315
16
0.630
4
0.157
C
Applicable
model No.
MS-H12
5
"11.5 "14
GX-12MU(B)
"0.453 "0.551
MS-H18
6
"17.5 "20
GX-18MU(B)
"0.689 "0.787
MS-H30
8
"29.4 "33
GX-30MU(B)
"1.157 "1.299
Material: Fluorine resin
6.1
0.240
B