GX-308M-B-N-J

GX-308M-B-N-J

  • 厂商:

    NAIS(松下)

  • 封装:

    圆柱形,有螺纹-M8

  • 描述:

    电感 接近传感器 0.047"(1.2mm) IP67,IP67G,IP69K 圆柱形,有螺纹 - M8

  • 数据手册
  • 价格&库存
GX-308M-B-N-J 数据手册
Amplifier Built-in / DC 3-wire Type Cylindrical Inductive Proximity Sensor GX-300 SERIES Recognition Small-diameter type only. Excluding bendingresistant cable type. Listing (Excluding small-diameter type) Standard Type Cylindrical Inductive Proximity Sensors with Improved Basic Performance Visible fro m ections dir all IO-Link compatible Sensor Models in Lineup M8 / M12 / M18 / M30 Threaded Type PNP Output, Normally Open Type * Switchable to Normally Closed Type 2020.11 industrial.panasonic.com/ac/e/ Standard type cylindrical inductive proximity sensors with improved basic performance GX-300 series Improved basic performance Response frequency of 5 kHz* allows the use of high-speed application * In the case of GX-303S The GX-303S boasts a response frequency of 5 kHz and realizes high speed response. The response frequency of other sensor models has been also improved by up to 4 times as compared to our conventional models. Since the GX-300 series responds quickly to sensor ON/OFF judgement, it works well with a high-speed application and contributes to the reduction of equipment cycle time. Typical examples (Shielded type) Type Response frequency of our conventional model ø3 mm ø0.118 in — ø4 mm ø0.157 in Significant improvement over conventional models! Response frequency of GX-300 standard sensing range type 5 kHz (GX-303S) 1 kHz 4 times 4 kHz (GX-304S) ø5.4 mm ø0.213 in 1.5 kHz 2.7 times 4 kHz (GX-305S) M5 threaded 1 kHz 4 times 4 kHz (GX-305M) M8 threaded 1 kHz 2 times 2 kHz (GX-308M) M12 threaded 450 Hz 3.3 times 1,500 Hz (GX-312M) M18 threaded 300 Hz 2 times 600 Hz (GX-318M) * Conventional model: ø3.8 / ø4.4 mm ø0.150 / ø0.173 in What is response frequency? A rotating plate having the standard sensing object pasted at constant intervals is placed in front of the proximity sensor. The plate is rotated while observing the sensing output. The maximum number of times per second at which sensing can be done, for which the corresponding sensing output can be obtained, is the maximum response frequency. In other words, the larger the numeric value of the response frequency is, the faster the response is. Example) Conversion of response frequency to response speed 1 kHz → 1-ms cycle 5 kHz → 0.2-ms cycle 2 a 2a Standard sensing object a Inductive proximity sensor a: Side length of standard sensing object 50% of maximum operation distance GX-300 SERIES Enhanced a degree of the detection margin Sensing over long distance The M8 / M12 / M18 / M30 threaded type sensors are available in standard sensing range type or long sensing range type (“K” at the end of model No.). The long sensing range means reliable detection with plenty of performance margin to spare. Sensing range comparison Conventional model: 10 mm 0.394 in M30 threaded type, shielded type Standard sensing range type: 10 mm 0.394 in Long sensing range type: 15 mm 0.591 in Conventional model: 22 mm 0.866 in M30 threaded type, non-shielded type Standard sensing range type: 18 mm 0.709 in Long sensing range type: 30 mm 1.181 in Minimum risk of collision or sensing error even if the distance to the sensing object changes due to equipment vibration If the distance to the sensing object changes due to equipment vibration or time-related degradation, the sensor may generate sensing errors including sensing failure in some cases. If the sensor is set up very close to the sensing object for the purpose of preventing detecting failures, the sensor may contact the sensing object and cause damage. The long sensing range models facilitate the sensor setup for reliable sensing since they detect the sensing object at a long distance. Positioning processing equipment The distance to the dog becomes longer Conventional due to equipment vibration and the sensor model may fail to detect the sensing object. Conventional model 1 mm 0.039 in Maximum operation distance Dog GX-308MK GX-300 Sensing error The long sensing range model can perform sensing over long distance to ensure stable detection. GX-308MK 2 mm 0.079 in Maximum operation distance Stable detection Reduced variation in maximum operation distance With the GX-300 series, variation in maximum operation distance is kept within ±10% * ±15% in the case of the previous GX series. Variation in the maximum operation distance of the ø3 / ø4 / ø5.4 mm ø0.118 / ø0.157 / ø0.213 in, M5 / M8 threaded type models has been also reduced as compared to the conventional models. 3 Improved usability Indicator visible 360 degrees The indicator is conveniently visible from any direction, thus facilitating installation check and operation confirmation. Conventional model GX-300 If the operation indicator position is adjusted to make the indicator visible, the sensor distance changes. In the small-diameter type sensors, the indicator light is visible at 4 locations. In the M8 and larger threaded type sensors, the high-brightness indicator and the resin containing dispersing agent allow the confirmation of the indicator from any angle to facilitate the cumbersome adjustment of installation position. GX-N series Small-diameter type Ind from ica an Indicator light visible at 4 locations Indicator visible only at 1 location GX series ible vis ection r r to di y M8 / M12 / M18 / M30 threaded type * The operation indicator flashes in green during I/O-Link communication. Further reduction of the size of small-diameter type sensors for easier embedment The small-diameter type sensors are 25.1 mm 0.988 in in depth while the conventional models measured 30 mm 1.181 in. (GX-303S measures 27.1 mm 1.067 in in depth.) The reduced unit size enables the installation of Comparison of depth dimensions the sensor in a smaller space. of small-diameter type sensors Conventional model (GX-5S) 30 mm 1.181 in 25.1 mm 0.988 in GX-305S Type Our conventional model GX-300 ø3.0 mm ø0.118 in ‒ 27.1 mm 1.067 in ø3.8 mm ø0.150 in 30 mm 1.181 in ‒ ø4.0 mm ø0.157 in ‒ 25.1 mm 0.988 in ø4.4 mm ø0.173 in 30 mm 1.181 in ‒ ø5.4 mm ø0.213 in 30 mm 1.181 in 25.1 mm 0.988 in M5 thread 30 mm 1.181 in Threaded section: 18 mm 0.709 in 25.1 mm 0.988 in Threaded section: 15.1 mm 0.594 in Depth reduced by 16% Extensive model lineup The GX-300 series includes 310 different sensor models. We offer various types of sensor models such as the cable type (cable length: 2 m 6.562 ft or 5 m 16.404 ft), connector type and pigtailed type. Furthermore, we can supply bending-resistant cable type models (cable length: 2 m 6.562 ft or 5 m 16.404 ft), which are suitable for installation on moving parts. (For the detail of our model lineup, see page 6 and following pages.) Cable type 4 Connector type Pigtailed type GX-300 SERIES Suitable for IoT applications IO-Link compatibility What is “IO-Link”? Evolution from ON/OFF judgment sensors to sensors capable of transmitting the detection level and sensor status information IO‑Link is an open communication technology according to IEC 61131-9 for the 1:1 bidirectional communication between the IO‑Link device (sensor or actuator) and the IO‑Link master. * Only the M8 / M12 / M18 / M30 threaded type, PNP output, normally open type models are compatible with IO-Link.  IO-Link compatible sensors can also be used as ordinary sensors (PNP output type). [+] [‒] Transmission of ON/OFF signal to host device such as PLC Tr output GX-312M-A-P ON OFF W  hen IO-Link compatible sensors are connected to the IO-Link master, they can transmit not only ON/OFF signal odbus Modbus but alsoM sensor information and operation mode switching information in both ways. So, the sensors can be TCP level TCP utilized for the visualization of manufacturing operations or for the incorporation of IoT technology. ■Typical field network To PLC To PLC *CC-Link IE Field and CC-Link are trademarks of Mitsubishi Electric Corporation, and are controlled by the CC-Link Partner Association. DeviceNet and EtherNet/IP are registered trademarks of ODVA (Open DeviceNet Vender Association, Inc.). EtherCAT is a registered trademark of Beckhoff Automation GmbH. Modbus is a registered trademark of Schneider Automation, Inc. IO-Link Master Unit for CC-Link IE Field SC-LG2-CEF-P master Green indicator flashes in 1-second intervals during I/O-Link communication. GX-312M-A-P IO-Link usage example 2 IO-Link usage example 1 Using the process data, the sensor transmits the detection level (8 bits) to the host device over IO-Link. ON/OFF signal + Sensor information The IO-Link device has an IODD (IO Device Description) file containing identification information such as the device vendor’s name and model number. Workers on the manufacturing floor can load and utilize this information. Operation mode switching information N.O. IO-Link usage example 3 Wire disconnection When wire breakage or short-circuit occurs, the sensor notifies the host device by using the IO-Link event notification function. This enables quick identification of malfunctioning part to ensure smooth maintenance. N.C. IO-Link usage example 4 The operation mode can be toggled between N.O. and N.C. using IO-Link communication. 5 GX-300 ORDER GUIDE Model No. GX-3 08 M L K - A - N -C5 Size 03: ø3.0 mm ø0.118 in 04: ø4.0 mm ø0.157 in 05: ø5.4 mm ø0.213 in / M5 08: M8 12: M12 18: M18 30: M30 Connecting method None: Standard 2 m 6.562 ft cable -C5: Standard 5 m 16.404 ft cable -R: Bending-resistant 2 m 6.562 ft cable -R5: Bending-resistant 5 m 16.404 ft cable -J: Pigtailed type -Z: Connector type Shape S: Non-threaded type M: Threaded type Output N: NPN output P: PNP output Shielded / Non-shielded None: Shielded L: Non-shielded type Sensing range None: Standard sensing range Operating mode A: Normally open B: Normally closed K: Long sensing range DC 3-wire type (Small-diameter, shielded type) Type Appearance (mm in) Sensing range (Note) Model No. GX-303S-A-N 0.8 mm 0.031 in ø3 ø0.118 27.1 1.067 0 to 0.56 mm 0 to 0.022 in Max. operation distance Stable sensing range GX-303S-B-N GX-303S-A-P Non-threaded type Small-diameter, shielded type GX-303S-B-P GX-304S-A-N ø4 ø0.157 25.1 0.988 1.2 mm 0.047 in GX-304S-B-N (0 to 0.84 mm 0 to 0.033 in) GX-304S-A-P GX-304S-B-P GX-305S-A-N ø5.4 ø0.213 25.1 0.988 1 mm 0.039 in GX-305S-B-N (0 to 0.7 mm 0 to 0.028 in) GX-305S-A-P GX-305S-B-P Threaded type GX-305M-A-N M5 25.1 0.988 1.2 mm 0.047 in GX-305M-B-N (0 to 0.84 mm 0 to 0.033 in) GX-305M-A-P GX-305M-B-P Output NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor Output operation Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Note: The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 6 GX-300 ORDER GUIDE DC 3-wire type (Shielded type) Type Appearance (mm in) Sensing range (Note 1) Model No. (Note 2) GX-308M-A-N 1.5 mm 0.059 in M8 37.8 1.488 Max. operation distance 0 to 1.2 mm 0 to 0.047 in Stable sensing range GX-308M-B-N GX-308M-A-P GX-308M-B-P Standard sensing range type GX-312M-A-N M12 47.1 1.854 2 mm 0.079 in GX-312M-B-N (0 to 1.6 mm 0 to 0.063 in) GX-312M-A-P GX-312M-B-P GX-318M-A-N M18 55.3 2.177 5 mm 0.197 in GX-318M-B-N (0 to 4 mm 0 to 0.157 in) GX-318M-A-P GX-318M-B-P GX-330M-A-N Shielded type Threaded type M30 60.3 2.374 10 mm 0.394 in GX-330M-B-N (0 to 8 mm 0 to 0.315 in) GX-330M-A-P GX-330M-B-P GX-308MK-A-N M8 37.8 1.488 2 mm 0.079 in GX-308MK-B-N (0 to 1.6 mm 0 to 0.063 in) GX-308MK-A-P GX-308MK-B-P GX-312MK-A-N Long sensing range type 4 mm 0.157 in M12 47.1 1.854 (0 to 3.2 mm 0 to 0.126 in) GX-312MK-B-N GX-312MK-A-P GX-312MK-B-P GX-318MK-A-N 8 mm 0.315 in M18 55.3 2.177 (0 to 6.4 mm 0 to 0.252 in) GX-318MK-B-N GX-318MK-A-P GX-318MK-B-P GX-330MK-A-N 15 mm 0.591 in M30 60.3 2.374 (0 to 12 mm 0 to 0.472 in) GX-330MK-B-N GX-330MK-A-P GX-330MK-B-P Output NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor Output operation Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 2) The PNP output, normally open type models [GX-3□M(K)-A-P(-□)] are compatible with IO-Link. The PNP output, normally closed type models and all NPN output type models do not support IO-Link. 7 GX-300 ORDER GUIDE DC 3-wire type (Non-shielded type) Type Appearance (mm in) Sensing range (Note 1) Model No. (Note 2) GX-308ML-A-N 2 mm 0.079 in M8 37.8 1.488 Max. operation distance 0 to 1.6 mm 0 to 0.063 in Stable sensing range GX-308ML-B-N GX-308ML-A-P GX-308ML-B-P Standard sensing range type GX-312ML-A-N M12 47.1 1.854 5 mm 0.197 in GX-312ML-B-N (0 to 4 mm 0 to 0.157 in) GX-312ML-A-P GX-312ML-B-P GX-318ML-A-N M18 55.3 2.177 10 mm 0.394 in GX-318ML-B-N (0 to 8 mm 0 to 0.315 in) GX-318ML-A-P GX-318ML-B-P GX-330ML-A-N M30 Threaded type Non-shielded type 18 mm 0.709 in 60.3 2.374 GX-330ML-B-N GX-330ML-A-P (0 to 14.4 mm 0 to 0.567 in) GX-330ML-B-P GX-308MLK-A-N 4 mm 0.157 in M8 37.8 1.488 GX-308MLK-B-N GX-308MLK-A-P (0 to 3.2 mm 0 to 0.126 in) GX-308MLK-B-P GX-312MLK-A-N Long sensing range type 8 mm 0.315 in M12 47.1 1.854 GX-312MLK-B-N GX-312MLK-A-P (0 to 6.4 mm 0 to 0.252 in) GX-312MLK-B-P GX-318MLK-A-N 16 mm 0.630 in M18 55.3 2.177 GX-318MLK-B-N GX-318MLK-A-P (0 to 12.8 mm 0 to 0.504 in) GX-318MLK-B-P GX-330MLK-A-N 30 mm 1.181 in M30 82.3 3.240 (0 to 24 mm 0 to 0.945 in) GX-330MLK-B-N GX-330MLK-A-P GX-330MLK-B-P Output NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor Output operation Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 2) The PNP output, normally open type models [GX-3□ML(K)-A-P(-□)] are compatible with IO-Link. The PNP output, normally closed type models and all NPN output type models do not support IO-Link. 8 GX-300 ORDER GUIDE 5 m 16.404 ft cable length type 5 m 16.404 ft cable length type (standard: 2 m 6.562 ft) is also available. When ordering this type, suffix “-C5” to the model No. (e.g.) 5 m 16.404 ft cable length type of GX-303S-A-N is “GX-303S-A-N-C5”. Bending-resistant cable type (2 m 6.562 ft / 5 m 16.404 ft cable length) The shielded, non-threaded type sensors (ø4 mm ø0.157 in / ø5.4 mm ø0.213 in) and threaded type sensors (M5 / M8) are available with a bending-resistant cable (cable length: 2 m 6.562 ft or 5 m 16.404 ft). (Note that the ø5.4 mm ø0.213 in size, normally closed type sensors are not available with a 5-m-long bending-resistant cable.) When ordering bending-resistant 2 m 6.562 ft cable type, suffix “-R” to the model No. When ordering bending-resistant 5 m 16.404 ft cable type, suffix “-R5” to the model No. (e.g.) Bending-resistant 2 m 6.562 ft cable type of GX-304S-A-N is “GX-304S-A-N-R”. (e.g.) Bending-resistant 5 m 16.404 ft cable type of GX-304S-A-N is “GX-304S-A-N-R5”. Pigtailed type The threaded type sensors (M8 / M12 / M18 / M30) are available in the pigtailed type. (Connector: M12) When ordering this type, suffix “-J” to the model No. (e.g.) Pigtailed type of GX-308M-A-N is “GX-308M-A-N-J”. Connector type The threaded type sensors (M12 / M18 / M30) are available in the connector type. When ordering this type, suffix “-Z” to the model No. (e.g.) Connector type of GX-312M-A-N is “GX-312M-A-N-Z”. • List of connection systems 5 m 16.404 ft cable length (“-C5” at the end of model No.) Bending-resistant 2 m 6.562 ft cable (“-R” at the end of model No.) Bending-resistant 5 m 16.404 ft cable (“-R5” at the end of model No.) Pigtailed type (“-J” at the end of model No.) (Note) Connector type (“-Z” at the end of model No.) ø3.0 mm ø0.118 in Available — — — — ø4.0 mm ø0.157 in Available Available Available — — ø5.4 mm ø0.213 in Available Available Available *Excluding normally closed type — — M5 Available Available Available — — M8 Available Available Available Available — M12 Available — — Available Available M18 Available — — Available Available M30 Available — — Available Available M8 Available — — Available — M12 Available — — Available Available M18 Available — — Available Available M30 Available — — Available Available Type Smalldiameter, shielded type Shielded type Non-shielded type Note: Please purchase mating cables separately when using pigtailed type models. • Mating cable Model No. Description CN-24S-C2 Length: 2 m 6.562 ft CN-24S-C5 Length: 5 m 16.404 ft Note: AWG20 4-core cable with M12 Smartclick connector on one end Cable outside diameter: ø6 mm ø0.236 in M12 connector Mating cable CN-24S-C2 (Length: 2 m 6.562 ft) CN-24S-C5 (Length: 5 m 16.404 ft) is a trademark of OMRON Corporation. 9 GX-300 SPECIFICATIONS DC 3-wire type (Small-diameter, shielded type) Small-diameter, shielded type Type Model No. Normally open Item (Note 2) Normally closed Regulatory compliance Max. operation distance (Note 3) Non-threaded type Threaded type GX-303S-A-□ GX-304S-A-□ GX-305S-A-□ GX-305M-A-□ GX-303S-B-□ GX-304S-B-□ GX-305S-B-□ GX-305M-B-□ CE Marking (EMC Directive, RoHS Directive), UL Recognition Certification (excluding bending-resistant cable type) 0.8 mm 0.031 in ±10 % 1.2 mm 0.047 in ±10 % Stable sensing range (Note 3) 0 to 0.56 mm 0 to 0.022 in Standard sensing object Iron sheet 3 × 3 × t 1 mm 0.118 × 0.118 × t 0.039 in Hysteresis 1.0 mm 0.039 in ±10 % 1.2 mm 0.047 in ±10 % 0 to 0.84 mm 0 to 0.033 in 0 to 0.7 mm 0 to 0.028 in 0 to 0.84 mm 0 to 0.033 in Iron sheet 4 × 4 × t 1 mm 0.157 × 0.157 × t 0.039 in Iron sheet 5.4 × 5.4 × t 1 mm 0.213 × 0.213 × t 0.039 in Iron sheet 4 × 4 × t 1 mm 0.157 × 0.157 × t 0.039 in 15 % or less of operation distance (with standard sensing object) Supply voltage (Note 4) 10 to 30 V DC [including 10 % ripple (p-p)] Current consumption Output (Note 5) 10 mA or less NPN open-collector transistor • Maximum sink current: 100 mA or less (50 mA or less for GX-303S) • Applied voltage: 30 V DC or less (between output to 0 V) • Residual voltage: 2 V or less (Note 6) (at max. sink current) Short-circuit protection Response frequency (Note 7) Incorporated 5 kHz 4 kHz Operation indicator Orange LED (lights up when the output is ON) Pollution degree 3 Environmental resistance Altitude 2,000 m 6561.68 ft or less Protection Ambient temperature IP67 (IEC) -25 to +70 °C -13 to +158 °F, Storage: -25 to +70 °C -13 to +158 °F (No condensation or icing allowed) Ambient humidity Voltage withstandability PNP open-collector transistor • Maximum source current: 100 mA or less (50 mA or less for GX-303S) • Applied voltage: 30 V DC or less (between output to +V) • Residual voltage: 2 V or less (Note 6) (at max. source current) 35 to 95 % RH, Storage: 35 to 95 % RH (No condensation allowed) 500 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 50 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each 500 m/s2 acceleration in X, Y and Z directions ten times each Shock resistance Temperature Sensing range characteristics variation Voltage characteristics Within ±15 % of sensing range at +23 °C +73 °F in ambient temperature range Within ±2.5 % for ±15 % fluctuation of the rated supply voltage Enclosure: Stainless steel (SUS303) [Brass (Nickel plated) for GX-305S] Sensing part: Heat-resistant ABS, Cable: Polyvinyl chloride (PVC) Material Mating cable 0.09 mm2 3-core ø2.4 mm ø0.094 in cabtyre cable, 2 m 6.562 ft long Weight (Note 6) Net weight: 20 g approx. Gross weight: 40 g approx. Accessories 0.14 mm2 3-core ø2.9 mm ø0.114 in cabtyre cable, 2 m 6.562 ft long (Note 8) Net weight: 25 g approx. Gross weight: 50 g approx. — Net weight: 30 g approx. Gross weight: 50 g approx. Nut: 2 pcs., Toothed lock washer: 1 pc. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73 °F. 2) The sensors with “N” indicated instead of □ in their model Nos. are NPN output type. The sensors with “P” are PNP output type. 3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 4) When used at a power of 12 V, the product is less susceptible to the effects of internal self-heat generation and therefore a more stable repeat accuracy can be obtained. 5) When the output is 20 mA or less, the product is less susceptible to the effects of internal self-heat generation and therefore a more stable repeat accuracy can be obtained. 6) When the cable length is 2 m 6.562 ft. 7) The response frequency is an average value. 8) The bending-resistant cable type models come with a 0.15 mm2 3-core bending-resistant ø2.9 mm ø0.114 in cabtyre cable. 10 GX-300 SPECIFICATIONS DC 3-wire type (Shielded type) Shielded type Type Threaded type Standard sensing range Model Normally open GX-308M-A-□ No. Item (Note 2) Normally closed GX-308M-B-□ Regulatory compliance Max. operation distance (Note 3) Stable sensing range (Note 3) Standard sensing object Hysteresis Supply voltage Current consumption IO-Link communication Baud rate Output Process data (C/Q) Minimum (Note 4) cycle time Vendor ID Device ID Long sensing range GX-312M-A-□ GX-318M-A-□ GX-330M-A-□ GX-308MK-A-□ GX-312MK-A-□ GX-318MK-A-□ GX-330MK-A-□ GX-312M-B-□ GX-318M-B-□ GX-330M-B-□ GX-308MK-B-□ GX-312MK-B-□ GX-318MK-B-□ GX-330MK-B-□ CE Marking (EMC Directive, RoHS Directive), UL/c-UL Listing Certification 1.5 mm 2 mm 5 mm 10 mm 2 mm 4 mm 8 mm 15 mm 0.059 in ±10 % 0.079 in ±10 % 0.197 in ±10 % 0.394 in ±10 % 0.079 in ±10 % 0.157 in ±10 % 0.315 in ±10 % 0.591 in ±10 % 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 1.6 mm 0 to 3.2 mm 0 to 6.4 mm 0 to 12 mm 0 to 0.047 in 0 to 0.063 in 0 to 0.157 in 0 to 0.315 in 0 to 0.063 in 0 to 0.126 in 0 to 0.252 in 0 to 0.472 in Iron sheet Iron sheet Iron sheet Iron sheet Iron sheet Iron sheet Iron sheet Iron sheet 8 × 8 × t 1 mm 12 × 12 × t 1 mm 18 × 18 × t 1 mm 30 × 30 × t 1 mm 8 × 8 × t 1 mm 12 × 12 × t 1 mm 24 × 24 × t 1 mm 45 × 45 × t 1 mm 0.315 × 0.315 0.472 × 0.472 0.709 × 0.709 1.181 × 1.181 0.315 × 0.315 0.472 × 0.472 0.945 × 0.945 1.772 × 1.772 × t 0.039 in × t 0.039 in × t 0.039 in × t 0.039 in × t 0.039 in × t 0.039 in × t 0.039 in × t 0.039 in 10 % or less of operation distance (with standard sensing object) 15 % or less of operation distance (with standard sensing object) 10 to 30 V DC [including 10 % ripple (p-p)], Class 2 16 mA or less IO-Link Specification Ver1.1 COM3 (230.4 kbps) PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2) 0.4 ms Environmental resistance 834 (0x342) GX-308□: 0x70000, GX-312□: 0x70001, GX-318□: 0x70002, GX-330□: 0x70003 PNP open-collector transistor NPN open-collector transistor • Maximum source current: 200 mA or less • Maximum sink current: 200 mA or less Output [GX-308M(K)-□: 200 mA or less (-40 to +70 °C -40 to +158 °F), [GX-308M(K)-□: 200 mA or less (-40 to +70 °C -40 to +158 °F), 100 mA or less (+70 to +85 °C +158 to +185 °F)] 100 mA or less (+70 to +85 °C +158 to +185 °F)] • Applied voltage: 30 V DC or less (between output to +V) • Applied voltage: 30 V DC or less (between output to 0 V)  esidual voltage: 2 V or less (Note 5) (at source current 200 mA or less) • Residual voltage: 2 V or less (Note 5) (at sink current 200 mA or less) • R Short-circuit protection Incorporated Response frequency (Note 6) 2,000 Hz 1,500 Hz 600 Hz 400 Hz 1,500 Hz 1,000 Hz 500 Hz 250 Hz Standard I/O mode (SIO mode): Operation indicator (orange, ON), Communication indicator (green, OFF) Operation indicator IO-LINK communication mode (COM mode): Operation indicator (orange, ON), Communication indicator [green, flashing (1-sec intervals)] Pollution degree 3 Altitude 2,000 m 6561.68 ft or less Protection IP67 (IEC), IP69K, IP67G [IP67 (IEC), IP69K for connector type] -40 to +85°C -40 to +185°F, Storage: -45 to +85°C -49 to +185°F (No condensation or icing allowed) Ambient temperature (UL temperature rating for pigtailed type: -25 to +70 °C -13 to +158 °F) Ambient humidity 35 to 95 % RH, Storage: 35 to 95 % RH (No condensation allowed) Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 50 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each Shock resistance 1,000 m/s2 (GX-308M(K)-□: 500 m/s2) acceleration in X, Y and Z directions ten times each Temperature Within ±15% of sensing range at +23 °C +73°F in ambient temperature range Sensing characteristics Within ±10% of sensing range at +23 °C +73°F in temperature range of -25 to +70 °C -13 to +158 °F range Voltage variation Within ±1% for ±15 % fluctuation of the rated supply voltage characteristics Enclosure: Nickel-plated brass [stainless steel (SUS303) for GX-308M(K)-□], Material Sensing part: Polybutylene terephthalate (PBT), Cable: Polyvinyl chloride (PVC) 2 0.2 mm 3-core oil resistant 0.2 mm2 3-core oil resistant 0.2 mm2 3-core oil resistant 0.2 mm2 3-core oil resistant ø4 mm ø0.157 in cabtyre cable, ø6 mm ø0.236 in cabtyre cable, ø4 mm ø0.157 in cabtyre cable, ø6 mm ø0.236 in cabtyre cable, Mating cable 2 m 6.562 ft long (Note 7) 2 m 6.562 ft long (Note 8) 2 m 6.562 ft long (Note 7) 2 m 6.562 ft long (Note 8) Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: Cable type 55 g approx. 70 g approx. 140 g approx. 210 g approx. 55 g approx. 70 g approx. 140 g approx. 210 g approx. (Note 5) Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: 80 g approx. 95 g approx. 160 g approx. 240 g approx. 80 g approx. 95 g approx. 160 g approx. 240 g approx. Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: 25 g approx. 40 g approx. 70 g approx. 140 g approx. 25 g approx. 40 g approx. 70 g approx. 140 g approx. Weight Pigtailed type Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: 55 g approx. 70 g approx. 100 g approx. 170 g approx. 55 g approx. 70 g approx. 100 g approx. 170 g approx. Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: 25 g approx. 50 g approx. 130 g approx. Connector 25 g approx. 50 g approx. 130 g approx. — — Gross weight: Gross weight: Gross weight: type Gross weight: Gross weight: Gross weight: 75 g approx. 150 g approx. 55 g approx. 75 g approx. 150 g approx. 55 g approx. Accessories Nut: 2 pcs., Toothed lock washer: 1 pc. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23°C +73 °F. 2) The sensors with “N” indicated instead of □ in their model No. are NPN output type. The sensors with “P” are PNP output type. 3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 4) PNP output, normally closed type models and all NPN output models do not support IO-Link. 5) When the cable length is 2 m 6.562 ft. 6) The response frequency is an average value. 7) The bending-resistant cable type comes with a 0.2 mm2 3-core bending-resistant ø4 mm ø0.157 in cabtyre cable. 8) The bending-resistant cable type comes with a 0.2 mm2 3-core bending-resistant ø6 mm ø0.236 in cabtyre cable. 11 GX-300 SPECIFICATIONS DC 3-wire type (Non-shielded type) Non-shielded type Type Threaded type Standard sensing range Model Normally open GX-308ML-A-□ No. Item (Note 2) Normally closed GX-308ML-B-□ Regulatory compliance Max. operation distance (Note 3) Stable sensing range (Note 3) Standard sensing object Hysteresis Supply voltage Current consumption IO-Link communication Baud rate Output Process data (C/Q) (Note 4) Minimum cycle time Vendor ID Device ID Output Long sensing range GX-312ML-A-□ GX-318ML-A-□ GX-330ML-A-□ GX-308MLK-A-□ GX-312MLK-A-□ GX-318MLK-A-□ GX-330MLK-A-□ GX-312ML-B-□ GX-318ML-B-□ GX-330ML-B-□ GX-308MLK-B-□ GX-312MLK-B-□ GX-318MLK-B-□ GX-330MLK-B-□ CE Marking (EMC Directive, RoHS Directive), UL/c-UL Listing Certification 2 mm 5 mm 10 mm 18 mm 4 mm 8 mm 16 mm 30 mm 0.079 in ±10 % 0.197 in ±10 % 0.394 in ±10 % 0.709 in ±10 % 0.157 in ±10 % 0.315 in ±10 % 0.630 in ±10 % 1.181 in ±10 % 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14.4 mm 0 to 3.2 mm 0 to 6.4 mm 0 to 12.8 mm 0 to 24 mm 0 to 0.063 in 0 to 0.157 in 0 to 0.315 in 0 to 0.567 in 0 to 0.126 in 0 to 0.252 in 0 to 0.504 in 0 to 0.945 in Iron sheet Iron sheet Iron sheet Iron sheet Iron sheet Iron sheet Iron sheet Iron sheet 8 × 8 × t 1 mm 15 × 15 × t 1 mm 30 × 30 × t 1 mm 54 × 54 × t 1 mm 12 × 12 × t 1 mm 24 × 24 × t 1 mm 48 × 48 × t 1 mm 90 × 90 × t 1 mm 0.315 × 0.315 0.591 × 0.591 1.181 × 1.181 2.126 × 2.126 0.472 × 0.472 0.945 × 0.945 1.89 × 1.89 × 3.543 × 3.543 × t 0.039 in × t 0.039 in × t 0.039 in × t 0.039 in × t 0.039 in × t 0.039 in t 0.039 in × t 0.039 in 10% or less of operation distance (with standard sensing object) 15 % or less of operation distance (with standard sensing object) 10 to 30 V DC [including 10 % ripple (p-p)], Class 2 16 mA or less IO-Link Specification Ver1.1 COM3 (230.4 kbps) PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2) 0.4 ms 834 (0x342) GX-308□: 0x70000, GX-312□: 0x70001, GX-318□: 0x70002, GX-330□: 0x70003 NPN open-collector transistor PNP open-collector transistor • Maximum sink current: 200 mA or less • Maximum source current: 200 mA or less [GX-308ML(K)-□: 200 mA or less (-40 to +70 °C -40 to +158 °F), [GX-308ML(K)-□: 200 mA or less (-40 to +70 °C -40 to +158 °F), 100 mA or less (+70 to +85 °C +158 to +185 °F)] 100 mA or less (+70 to +85 °C +158 to +185 °F)] • Applied voltage: 30 V DC or less (between output to 0 V) • Applied voltage: 30 V DC or less (between output to +V) •R  esidual voltage: 2 V or less (Note 5) (at sink current 200 mA or less) • R  esidual voltage: 2 V or less (Note 5) (at source current 200 mA or less) Incorporated 1,000 Hz 800 Hz 400 Hz 100 Hz 1,000 Hz 800 Hz 400 Hz 100 Hz Standard I/O mode (SIO mode): Operation indicator (orange, ON), Communication indicator (green, OFF) Operation indicator IO-LINK communication mode (COM mode): Operation indicator (orange, ON), Communication indicator [green, flashing (1-sec intervals)] Pollution degree 3 Altitude 2,000 m 6561.68 ft or less Protection IP67 (IEC), IP69K, IP67G [IP67 (IEC), IP69K for connector type] -40 to +85 °C -40 to +185 °F, Storage: -45 to +85 °C -49 to +185 °F (No condensation or icing allowed) Ambient temperature (UL temperature rating for relay connector type: -25 to +70 °C -13 to +158 °F) Ambient humidity 35 to 95 % RH, Storage: 35 to 95 % RH (No condensation allowed) Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 50 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each Shock resistance 1,000 m/s2 (GX-308ML(K)-□: 500 m/s2) acceleration in X, Y and Z directions ten times each Temperature Within ±15% of sensing range at +23 °C +73°F in ambient temperature range Sensing characteristics Within ±10% of sensing range at +23 °C +73°F in temperature range of -25 to +70 °C -13 to +158 °F range Voltage variation Within ±1% for ±15 % fluctuation of the rated supply voltage characteristics Enclosure: Nickel-plated brass [stainless steel (SUS303) for GX-308ML(K)-□], Material Sensing part: Polybutylene terephthalate (PBT), Cable: Polyvinyl chloride (PVC) 0.2 mm2 3-core oil resistant 0.2 mm2 3-core oil resistant 0.2 mm2 3-core oil resistant 0.2 mm2 3-core oil resistant ø4 mm ø0.157 in cabtyre cable, ø6 mm ø0.236 in cabtyre cable, ø4 mm ø0.157 in cabtyre cable, ø6 mm ø0.236 in cabtyre cable, Mating cable 2 m 6.562 ft long (Note 7) 2 m 6.562 ft long (Note 8) 2 m 6.562 ft long (Note 7) 2 m 6.562 ft long (Note 8) Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: Cable type 55 g approx. 70 g approx. 140 g approx. 200 g approx. 55 g approx. 70 g approx. 140 g approx. 240 g approx. (Note 5) Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: 80 g approx. 95 g approx. 170 g approx. 230 g approx. 80 g approx. 95 g approx. 170 g approx. 280 g approx. Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: 25 g approx. 40 g approx. 75 g approx. 140 g approx. 25 g approx. 40 g approx. 75 g approx. 170 g approx. Weight Pigtailed type Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: Gross weight: 55 g approx. 65 g approx. 100 g approx. 160 g approx. 55 g approx. 65 g approx. 100 g approx. 220 g approx. Net weight: Net weight: Net weight: Net weight: Net weight: Net weight: 25 g approx. 55 g approx. 160 g approx. Connector 25 g approx. 55 g approx. 120 g approx. — — Gross weight: Gross weight: Gross weight: type Gross weight: Gross weight: Gross weight: 55 g approx. 80 g approx. 200 g approx. 55 g approx. 80 g approx. 150 g approx. Accessories Nut: 2 pcs., Toothed lock washer: 1 pc. Environmental resistance Short-circuit protection Response frequency (Note 6) Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23°C +73 °F. 2) The sensors with “N” indicated instead of □ in their model No. are NPN output type. The sensors with “P” are PNP output type. 3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 4) PNP output, normally closed type models and all NPN output models do not support IO-Link. 5) When the cable length is 2 m 6.562 ft. 6) The response frequency is an average value. 7) The bending-resistant cable type comes with a 0.2 mm2 3-core bending-resistant ø4 mm ø0.157 in cabtyre cable. 8) The bending-resistant cable type comes with a 0.2 mm2 3-core bending-resistant ø6 mm ø0.236 in cabtyre cable. 12 GX-300 I/O CIRCUIT AND WIRING DIAGRAMS GX-3□S-□-N  GX-305M-□-N NPN output type I/O circuit diagram Wiring diagram Color code Color code Brown Sensor circuit (Brown) +V Load (Black) Output Tr ZD D 100 mA max. (Note) + − Black 10 to 30 V DC Load + − 10 to 30 V DC Blue (Blue) 0 V Internal circuit Users’ circuit Note: Only GX-303S is 50 mA max. Symbols... D: Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: NPN output transistor GX-3□S-□-P  GX-305M-□-P PNP output type I/O circuit diagram Wiring diagram Color code Sensor circuit D Tr ZD Color code Brown (Brown) +V 100 mA max. (Note) (Black) Output Load + − + Black 10 to 30 V DC Blue Load − 10 to 30 V DC (Blue) 0 V Internal circuit Users’ circuit Note: Only GX-303S is 50 mA max. Symbols... D: Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: PNP output transistor GX-3□M(K)-A-N  GX-3□ML(K)-A-N * Excluding M5 threaded type NPN output, Normally open type I/O circuit diagram Wiring diagram Color code / Connector pin No. Color code / Connector pin No. Sensor circuit (Brown / 1) +V Brown / 1 Load (Black / 4) Output Tr ZD D Internal circuit 200 mA max. (Note) + − Black / 4 10 to 30 V DC Users’ circuit Symbols... D: Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: NPN output transistor + − 10 to 30 V DC Blue / 3 (Blue / 3) 0 V Note: In the case of the M8 threaded type: 200 mA max. (at -40 to +70 °C -40 to +158 °F), 100 mA max. (at +70 to +85 °C +158 to +185 °F) Load Connector pin diagram Pigtailed type Connector type 2 Not connected 3 0V 1 +V 4 Output Mating cable CN-24S-C□ Color code of mating cable / Connector pin No. (Brown / 1) + (White / 2) Not connected (Blue / 3) (Black / 4) Output 13 GX-300 I/O CIRCUIT AND WIRING DIAGRAMS GX-3□M(K)-B-N  GX-3□ML(K)-B-N * Excluding M5 threaded type NPN output, Normally closed type I/O circuit diagram Wiring diagram Color code / Connector pin No. Color code / Connector pin No. Sensor circuit (Brown / 1) +V Brown / 1 Load (White / 2) Output Tr ZD D 200 mA max. (Note) + − White / 2 10 to 30 V DC Connector pin diagram Note: In the case of the M8 threaded type: 200 mA max. (at -40 to +70 °C -40 to +158 °F), 100 mA max. (at +70 to +85 °C +158 to +185 °F) Pigtailed type Connector type Symbols... D: Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: NPN output transistor 1 +V 2 Output 4 Not connected 3 0V Mating cable CN-24S-C□ GX-3□M(K)-A-P  GX-3□ML(K)-A-P Color code of mating cable / Connector pin No. (Brown / 1) + (White / 2) Output (Blue / 3) (Black / 4) Not connected * Excluding M5 threaded type PNP output, Normally open type I/O circuit diagram Wiring diagram Color code / Connector pin No. Standard I/O mode (SIO mode) Brown / 1 Color code / Connector pin No. Sensor circuit Tr ZD 200 mA max. (Note) Load + − Blue / 3 Pigtailed type Connector type Users’ circuit 2 Not connected Symbols... D: Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: PNP output transistor 3 0V IO-Link communication mode (COM mode) Color code / Connector pin No. Sensor circuit (Brown / 1) +V L+ / 1 200 mA max. (Note) C/Q / 4 (Black / 4) Output (Blue / 3) 0 V Internal circuit Users’ circuit L− / 3 IO-Link master Notes: 1) In the case of the M8 threaded type: 200 mA max. (at -40 to +70 °C -40 to +158 °F), 100 mA max. (at +70 to +85 °C +158 to +185 °F) 2) In the IO-Link mode, the cable between the IO‑Link master and sensor must have a length of 20 m 65.617 ft or less. Symbols... D: Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: PNP output transistor 14 1 +V 4 Output Mating cable CN-24S-C□ ZD − Connector pin diagram Note: In the case of the M8 threaded type: 200 mA max. (at -40 to +70 °C -40 to +158 °F), 100 mA max. (at +70 to +85 °C +158 to +185 °F) Tr Load 10 to 30 V DC (Blue / 3) 0 V D + Black / 4 (Brown / 1) +V (Black / 4) Output Internal circuit 10 to 30 V DC Blue / 3 Users’ circuit D + − (Blue / 3) 0 V Internal circuit Load Color code of mating cable / Connector pin No. (Brown / 1) + (White / 2) Not connected (Blue / 3) (Black / 4) Output 10 to 30 V DC GX-300 I/O CIRCUIT AND WIRING DIAGRAMS GX-3□M(K)-B-P  GX-3□ML(K)-B-P * Excluding M5 threaded type PNP output, Normally closed type Wiring diagram I/O circuit diagram Color code / Connector pin No. Sensor circuit D Tr ZD Color code / Connector pin No. (Brown / 1) +V Brown / 1 200 mA max. (Note) (White / 2) Output + − Load Blue / 3 (Blue / 3) 0 V Internal circuit + White / 2 10 to 30 V DC Load − 10 to 30 V DC Connector pin diagram Users’ circuit Note: In the case of the M8 threaded type: 200 mA max. (at -40 to +70 °C -40 to +158 °F), 100 mA max. (at +70 to +85 °C +158 to +185 °F) Pigtailed type Connector type Symbols... D: Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: PNP output transistor 2 Output 3 0V 1 +V 4 Not connected Mating cable CN-24S-C□ Color code of mating cable / Connector pin No. (Brown / 1) + (White / 2) Output (Blue / 3) (Black / 4) Not connected SENSING CHARACTERISTICS (TYPICAL) All models Sensing field Setting distance L (mm in) 1.5 0.059 GX-304S-□ GX-305M-□ 1 0.039 0.5 0.020 GX-305S-□ Standard sensing object ℓ L GX-303S-□ 0 8 0.315 GX-330M-□ GX-318M-□ 6 0.236 4 0.157 2 0.079 0 GX-312M-□ GX-308M-□ 20 15 10 5 0 5 10 15 20 0.787 0.591 0.394 0.197 0.197 0.394 0.591 0.787 Left Center Right Operating point ℓ (mm in) 18 0.709 16 0.630 14 0.551 12 0.472 10 0.394 8 0.315 6 0.236 4 0.157 2 0.079 0 Standard sensing object ℓ L GX-330ML-□ GX-318ML-□ GX-312ML-□ GX-308ML-□ 40 30 20 10 0 10 20 30 40 1.575 1.181 0.787 0.394 0.394 0.787 1.181 1.575 Left Center Right Operating point ℓ (mm in) 16 0.630 14 0.551 12 0.472 10 0.394 8 0.315 6 0.236 4 0.157 2 0.079 0 30 1.181 Standard sensing object ℓ L GX-330MK-□ GX-318MK-□ GX-312MK-□ GX-308MK-□ 20 15 10 5 0 5 10 15 20 0.787 0.591 0.394 0.197 0.197 0.394 0.591 0.787 Left Center Right Operating point ℓ (mm in) Setting distance L (mm in) 10 0.394 Standard sensing object ℓ L Setting distance L (mm in) Setting distance L (mm in) 12 0.472 Setting distance L (mm in) 6 4 2 0 2 4 6 0.236 0.157 0.079 0.079 0.157 0.236 Left Center Right Operating point ℓ (mm in) 25 0.984 20 0.787 15 0.591 10 0.394 5 0.197 Standard sensing object ℓ L GX-330MLK-□ GX-318MLK-□ GX-312MLK-□ GX-308MLK-□ 0 40 30 20 10 0 10 20 30 40 1.575 1.181 0.787 0.394 0.394 0.787 1.181 1.575 Left Center Right Operating point ℓ (mm in) 15 GX-300 SENSING CHARACTERISTICS (TYPICAL) GX-303S-□ 0.9 0.035 0.8 0.031 0.7 0.028 0.6 0.024 0.5 0.020 0.4 0.016 0.3 0.012 0.2 0.008 0.1 0.004 Iron L 0 Stainless steel (SUS304) Brass Aluminum Copper Sensing object (size: a × a (mm) a × a (in)) t: 1 mm t 0.039 in As the sensing object size becomes smaller than the standard size (iron sheet 3 × 3 × t 1 mm 0.118 × 0.118 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between sensing range and repeatability 0.8 0.031 0.7 0.028 0.6 0.024 0.5 0.020 0.4 0.016 0.3 0.012 0.2 0.008 0.1 0.004 Sensing range L (mm in) Sensing range L (mm in) Correlation between sensing object size and sensing range 5 10 15 20 25 30 35 0.197 0.394 0.591 0.787 0.984 1.181 1.378 Sensing object side length a (mm in) 12 V DC 24 V DC Standard sensing object Iron sheet 3 × 3 × t 1 mm 0.118 × 0.118 × t 0.039 in ON point L Repeatability 0 0.05 0.002 0.1 0.004 0.15 0.006 0.2 0.008 Repeatability (mm in) GX-304S-□   GX-305M-□ 1.6 0.063 1.4 0.055 1.2 0.047 1.0 0.039 0.8 0.031 0.6 0.024 0.4 0.016 0.2 0.008 L Iron Sensing object (size: a × a (mm) a × a (in)) t: 1 mm t 0.039 in Stainless steel (SUS304) As the sensing object size becomes smaller than the standard size (iron sheet 4 × 4 × t 1 mm 0.157 × 0.157 in × t 0.039 in), the sensing range shortens as shown in the left figure. Brass Aluminum Copper 0 Correlation between sensing range and repeatability 1.2 0.047 Sensing range L (mm in) Sensing range L (mm in) Correlation between sensing object size and sensing range 12 V DC 24 V DC 1 0.039 0.8 0.031 0.6 0.024 Standard sensing object Iron sheet 4 × 4 × t 1 mm 0.157 × 0.157 × t 0.039 in ON point L Repeatability 0.4 0.016 0.2 0.008 5 10 15 20 25 30 35 0.197 0.394 0.591 0.787 0.984 1.181 1.378 Sensing object side length a (mm in) 0 0.05 0.002 0.1 0.004 0.15 0.006 0.2 0.008 Repeatability (mm in) GX-305S-□ 1.6 0.063 1.4 0.055 1.2 0.047 1.0 0.039 0.8 0.031 0.6 0.024 0.4 0.016 0.2 0.008 L Iron Stainless steel (SUS304) Brass Aluminum Copper 0 16 Sensing object (size: a × a (mm) a × a (in)) t: 1 mm t 0.039 in 5 10 15 20 25 30 35 0.197 0.394 0.591 0.787 0.984 1.181 1.378 Sensing object side length a (mm in) As the sensing object size becomes smaller than the standard size (iron sheet 5.4 × 5.4 × t 1 mm 0.213 × 0.213 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between sensing range and repeatability 1.2 0.047 Sensing range L (mm in) Sensing range L (mm in) Correlation between sensing object size and sensing range 12 V DC 1 0.039 24 V DC 0.8 0.031 0.6 0.024 Standard sensing object Iron sheet 5.4 × 5.4 × t 1 mm 0.213 × 0.213 × t 0.039 in ON point L Repeatability 0.4 0.016 0.2 0.008 0 0.05 0.002 0.1 0.004 0.15 0.006 Repeatability (mm in) 0.2 0.008 GX-300 SENSING CHARACTERISTICS (TYPICAL) GX-308M-□ Sensing range L (mm in) 2.5 0.098 2.0 0.079 L Sensing object (size: a × a (mm) a × a (in)) t: 1 mm t 0.039 in Iron 1.5 0.059 Stainless steel (SUS304) 1.0 0.039 Brass 0.5 0.020 As the sensing object size becomes smaller than the standard size (iron sheet 8 × 8 × t 1 mm 0.315 × 0.315 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range 250 225 175 Sensing object 8 × 8 mm 0.315 × 0.315 in t 1 mm t 0.039 in Iron 150 Stainless steel (SUS304) Aluminum 125 100 75 50 Aluminum Copper 0 L 200 Detection level Correlation between sensing object size and sensing range 25 0 5 10 15 20 25 0.197 0.394 0.591 0.787 0.984 Sensing object side length a (mm in) 0 2.5 3 0.5 1 1.5 2 0.020 0.039 0.059 0.079 0.098 0.118 Sensing range L (mm in) GX-312M-□ 3.0 0.118 2.5 0.098 L Sensing object (size: a × a (mm) a × a (in)) t: 1 mm t 0.039 in Iron 2.0 0.079 1.5 0.059 Stainless steel (SUS304) Brass 1.0 0.039 0.5 0.020 0.0 Aluminum Copper 0 As the sensing object size becomes smaller than the standard size (iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range 250 225 Detection level Sensing range L (mm in) Correlation between sensing object size and sensing range 200 L 175 Iron Sensing object 12 × 12 mm 0.472 × 0.472 in t 1 mm t 0.039 in 150 Stainless steel (SUS304) 125 100 Aluminum 75 50 25 0 5 10 15 20 25 0.197 0.394 0.591 0.787 0.984 Sensing object side length a (mm in) 0 0.5 1 1.5 2 2.5 3 3.5 4 0.020 0.039 0.059 0.079 0.098 0.118 0.138 0.157 Sensing range L (mm in) GX-318M-□ 6 Sensing object (size: a × a (mm) a × a (in)) 0.236 t: 1 mm t 0.039 in Iron L 5 0.197 Stainless steel 4 (SUS304) 0.157 3 0.118 Brass 2 0.079 1 0.039 0 Aluminum Copper 0 As the sensing object size becomes smaller than the standard size (iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range 250 225 Sensing object 18 × 18 mm 0.709 × 0.709 in t 1 mm t 0.039 in L 200 Detection level Sensing range L (mm in) Correlation between sensing object size and sensing range 175 150 Iron 125 100 Stainless steel (SUS304) Aluminum 75 50 25 0 10 20 30 40 50 0.394 0.787 1.181 1.575 1.969 Sensing object side length a (mm in) 0 1 2 3 4 5 6 7 8 9 10 0.039 0.079 0.118 0.157 0.197 0.236 0.276 0.315 0.354 0.394 Sensing range L (mm in) GX-330M-□ 12 0.472 10 0.394 L Stainless steel (SUS304) 8 0.315 6 0.236 Aluminum 4 0.157 2 0.079 0 Sensing object (size: a × a (mm) a × a (in)) t: 1 mm t 0.039 in Iron Brass Copper 0 10 20 30 40 50 60 0.394 0.787 1.181 1.575 1.969 2.362 Sensing object side length a (mm in) As the sensing object size becomes smaller than the standard size (iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range 250 225 L 200 Detection level Sensing range L (mm in) Correlation between sensing object size and sensing range Sensing object 30 × 30 mm 1.181 × 1.181 in t 1 mm t 0.039 in Iron 175 150 Stainless steel (SUS304) 125 100 Aluminum 75 50 25 0 0 2 4 6 8 10 12 14 16 18 20 0.079 0.157 0.236 0.315 0.394 0.472 0.551 0.630 0.709 0.787 Sensing range L (mm in) 17 GX-300 SENSING CHARACTERISTICS (TYPICAL) GX-308MK-□ 3.0 Sensing object 0.118 (size: a × a (mm) a × a (in)) 2.5 t: 1 mm t 0.039 in 0.098 L Iron 2.0 0.079 Stainless steel 1.5 (SUS304) 0.059 1.0 0.039 0.5 0.020 0.0 Aluminum Brass As the sensing object size becomes smaller than the standard size (iron sheet 8 × 8 × t 1 mm 0.315 × 0.315 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range 250 225 175 Sensing object 8 × 8 mm 0.315 × 0.315 in t 1 mm t 0.039 in Iron Stainless steel (SUS304) 150 125 100 Aluminum 75 50 25 0 Copper 0 L 200 Detection level Sensing range L (mm in) Correlation between sensing object size and sensing range 5 10 15 20 25 0.197 0.394 0.591 0.787 0.984 Sensing object side length a (mm in) 0 0.5 1 1.5 2 2.5 3 3.5 4 0.020 0.039 0.059 0.079 0.098 0.118 0.138 0.157 Sensing range L (mm in) GX-312MK-□ Sensing range L (mm in) 5 0.197 4 L 0.157 Sensing object (size: a × a (mm) a × a (in)) Iron t: 1 mm t 0.039 in Stainless steel (SUS304) 3 0.118 Aluminum 2 0.079 Copper 1 0.039 0 Brass 0 As the sensing object size becomes smaller than the standard size (iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range 250 225 L 200 Detection level Correlation between sensing object size and sensing range 175 Sensing object 12 × 12 mm 0.472 × 0.472 in t 1 mm t 0.039 in Iron Stainless steel (SUS304) 150 125 Aluminum 100 75 50 25 0 5 10 15 20 25 30 0.197 0.394 0.591 0.787 0.984 1.181 Sensing object side length a (mm in) 0 1 2 3 4 5 6 7 8 0.039 0.079 0.118 0.157 0.197 0.236 0.276 0.315 Sensing range L (mm in) GX-318MK-□ Sensing range L (mm in) 10 0.394 L 8 0.315 Sensing object (size: a × a (mm) a × a (in)) t: 1 mm t 0.039 in Iron Stainless steel (SUS304) 6 0.236 Aluminum 4 0.157 250 225 0 L 200 Copper 2 0.079 0 Brass As the sensing object size becomes smaller than the standard size (iron sheet 24 × 24 × t 1 mm 0.945 × 0.945 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range Detection level Correlation between sensing object size and sensing range 175 Sensing object 24 × 24 mm 0.945 × 0.945 in t 1 mm t 0.039 in Iron 150 Stainless steel (SUS304) 125 100 Aluminum 75 50 25 0 10 20 30 40 50 0.394 0.787 1.181 1.575 1.969 Sensing object side length a (mm in) 0 2 4 6 8 10 12 14 16 0.079 0.157 0.236 0.315 0.394 0.472 0.551 0.630 Sensing range L (mm in) GX-330MK-□ Sensing range L (mm in) 20 0.787 16 L 0.630 18 Stainless steel (SUS304) 12 0.472 Aluminum 8 0.315 4 0.157 0 Sensing object (size: a × a (mm) a × a (in)) t: 1 mm t 0.039 in Iron Brass Copper 0 10 20 30 40 50 60 70 0.394 0.787 1.181 1.575 1.969 2.362 2.756 Sensing object side length a (mm in) As the sensing object size becomes smaller than the standard size (iron sheet 45 × 45 × t 1 mm 1.772 × 1.772 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range 250 225 L 200 Detection level Correlation between sensing object size and sensing range Sensing object 45 × 45 mm 1.772 × 1.772 in t 1 mm t 0.039 in Iron 175 150 Stainless steel (SUS304) Aluminum 125 100 75 50 25 0 0 3 6 9 12 15 18 21 24 27 30 0.118 0.236 0.354 0.472 0.591 0.709 0.827 0.945 1.063 1.181 Sensing range L (mm in) GX-300 SENSING CHARACTERISTICS (TYPICAL) GX-308ML-□ 3.0 Sensing object 0.118 (size: a × a (mm) a × a (in)) 2.5 t: 1 mm t 0.039 in 0.098 L Iron 2.0 0.079 Stainless steel (SUS304) 1.5 0.059 Aluminum 1.0 0.039 0.5 0.020 0.0 Brass As the sensing object size becomes smaller than the standard size (iron sheet 8 × 8 × t 1 mm 0.315 × 0.315 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range 250 225 Detection level Sensing range L (mm in) Correlation between sensing object size and sensing range L 175 Iron 150 Sensing object 8 × 8 mm 0.315 × 0.315 in t 1 mm t 0.039 in Stainless steel (SUS304) 125 100 Aluminum 75 50 Copper 0 200 25 0 5 10 15 20 25 0.197 0.394 0.591 0.787 0.984 Sensing object side length a (mm in) 0 0.5 1 1.5 2 2.5 3 3.5 4 0.020 0.039 0.059 0.079 0.098 0.118 0.138 0.157 Sensing range L (mm in) GX-312ML-□ 6 Sensing object (size: a × a (mm) a × a (in)) 0.236 t: 1 mm t 0.039 in L Iron 5 0.197 Stainless steel 4 (SUS304) 0.157 3 0.118 Aluminum 2 0.079 250 225 0 L 200 175 Sensing object 15 × 15 mm 0.591 × 0.591 in t 1 mm t 0.039 in Iron 150 Stainless steel (SUS304) 125 100 Aluminum 75 50 Copper 1 0.039 0 Brass As the sensing object size becomes smaller than the standard size (iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range Detection level Sensing range L (mm in) Correlation between sensing object size and sensing range 25 0 10 20 30 40 50 0.394 0.787 1.181 1.575 1.969 Sensing object side length a (mm in) 0 1 2 3 4 5 6 7 8 9 10 0.039 0.079 0.118 0.157 0.197 0.236 0.276 0.315 0.354 0.394 Sensing range L (mm in) GX-318ML-□ 12 Sensing object (size: a × a (mm) a × a (in)) 0.472 t: 1 mm t 0.039 in L 10 Iron 0.394 8 0.315 Stainless steel (SUS304) 6 0.236 Aluminum 4 0.157 2 0.079 0 Brass As the sensing object size becomes smaller than the standard size (iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range 250 225 Detection level Sensing range L (mm in) Correlation between sensing object size and sensing range Copper 0 200 L 175 Iron 150 Sensing object 30 × 30 mm 1.181 × 1.181 in t 1 mm t 0.039 in Stainless steel (SUS304) 125 100 Aluminum 75 50 25 0 10 20 30 40 50 60 0.394 0.787 1.181 1.575 1.969 2.362 Sensing object side length a (mm in) 0 2 4 6 8 10 12 14 16 18 20 0.079 0.157 0.236 0.315 0.394 0.472 0.551 0.630 0.709 0.787 Sensing range L (mm in) GX-330ML-□ Sensing range L (mm in) 25 0.984 Sensing object (size: a × a (mm) a × a (in)) t: 1 mm t 0.039 in 20 L Iron 0.787 15 0.591 10 0.394 5 0.197 0 Stainless steel (SUS304) Aluminum Brass Copper 0 10 20 30 40 50 60 70 80 90 0.394 0.787 1.181 1.575 1.969 2.362 2.756 3.150 3.543 Sensing object side length a (mm in) As the sensing object size becomes smaller than the standard size (iron sheet 54 × 54 × t 1 mm 2.126 × 2.126 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range 250 225 Detection level Correlation between sensing object size and sensing range 200 L 175 Iron 150 Sensing object 54 × 54 mm 2.126 × 2.126 in t 1 mm t 0.039 in 125 Stainless steel (SUS304) 100 Aluminum 75 50 25 0 0 3 6 9 12 15 18 21 24 27 30 33 36 0.118 0.236 0.354 0.472 0.591 0.709 0.827 0.945 1.063 1.181 1.299 1.417 Sensing range L (mm in) 19 GX-300 SENSING CHARACTERISTICS (TYPICAL) GX-308MLK-□ Sensing range L (mm in) 5 0.197 L 4 0.157 Sensing object (size: a × a (mm) a × a (in)) t: 1 mm t 0.039 in Iron Stainless steel (SUS304) 3 0.118 2 0.079 Aluminum 1 0.039 0 Brass As the sensing object size becomes smaller than the standard size (iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range 250 225 Detection level Correlation between sensing object size and sensing range L 175 Iron 150 Sensing object 12 × 12 mm 0.472 × 0.472 in t 1 mm t 0.039 in Stainless steel (SUS304) 125 100 Aluminum 75 50 Copper 0 200 25 0 5 10 15 20 25 30 0.197 0.394 0.591 0.787 0.984 1.181 Sensing object side length a (mm in) 0 1 2 3 4 5 6 7 8 0.039 0.079 0.118 0.157 0.197 0.236 0.276 0.315 Sensing range L (mm in) GX-312MLK-□ Sensing range L (mm in) 10 0.394 Sensing object (size: a × a (mm) a × a (in)) t: 1 mm t 0.039 in 8 L Iron 0.315 Stainless steel 6 (SUS304) 0.236 Aluminum 4 Brass 0.157 250 225 0 200 L 175 Iron 150 Sensing object 24 × 24 mm 0.945 × 0.945 in t 1 mm t 0.039 in 125 Stainless steel (SUS304) 100 Aluminum 75 50 Copper 2 0.079 0 As the sensing object size becomes smaller than the standard size (iron sheet 24 × 24 × t 1 mm 0.945 × 0.945 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range Detection level Correlation between sensing object size and sensing range 25 0 10 20 30 40 50 0.394 0.787 1.181 1.575 1.969 Sensing object side length a (mm in) 0 2 4 6 8 10 12 14 16 0.079 0.157 0.236 0.315 0.394 0.472 0.551 0.630 Sensing range L (mm in) GX-318MLK-□ Sensing range L (mm in) 20 0.787 Sensing object (size: a × a (mm) a × a (in)) t: 1 mm t 0.039 in 16 L Iron 0.630 Stainless steel 12 (SUS304) 0.472 Aluminum 8 Brass 0.315 250 225 0 L 200 Copper 4 0.157 0 As the sensing object size becomes smaller than the standard size (iron sheet 48 × 48 × t 1 mm 1.890 × 1.890 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range Detection level Correlation between sensing object size and sensing range 175 Sensing object 48 × 48 mm 1.890 × 1.890 in t 1 mm t 0.039 in Iron Stainless steel (SUS304) 150 125 100 Aluminum 75 50 25 0 10 20 30 40 50 60 70 0.394 0.787 1.181 1.575 1.969 2.362 2.756 Sensing object side length a (mm in) 0 4 8 12 16 20 24 28 32 0.157 0.315 0.472 0.630 0.787 0.945 1.102 1.260 Sensing range L (mm in) GX-330MLK-□ 20 35 Sensing object (size: a × a (mm) a × a (in)) 1.378 t: 1 mm t 0.039 in 30 L Iron 1.181 Stainless steel 25 (SUS304) 0.984 20 0.787 Aluminum 15 Brass 0.591 10 0.394 Copper 5 0.197 0 0 10 20 30 40 50 60 70 80 90 0.394 0.787 1.181 1.575 1.969 2.362 2.756 3.150 3.543 Sensing object side length a (mm in) As the sensing object size becomes smaller than the standard size (iron sheet 90 × 90 × t 1 mm 3.543 × 3.543 × t 0.039 in), the sensing range shortens as shown in the left figure. Correlation between monitor output and sensing range 250 225 L 200 Detection level Sensing range L (mm in) Correlation between sensing object size and sensing range Sensing object 90 × 90 mm 3.543 × 3.543 in t 1 mm t 0.039 in Iron 175 150 125 Stainless steel (SUS304) 100 Aluminum 75 50 25 0 0 10 20 30 40 50 60 0.394 0.787 1.181 1.575 1.969 2.362 Sensing range L (mm in) GX-300 PRECAUTIONS FOR PROPER USE • This catalog is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use. • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Mounting hole and nut dimensions Model No. D (mm in) E (mm in) GX-303S ø3.3+0.5 0 ø0.130+0.0197 0 - GX-304S ø4.2+0.5 0 ø0.165+0.0197 0 - D GX-305S +0.5 0 +0.0197 0 ø5.7 ø0.224 - Nut dimensions GX-305M ø5.5+0.5 0 ø0.217+0.0197 0 - GX-308M(K) GX-308ML(K) ø8.5+0.5 0 ø0.335+0.0197 0 13 0.512 GX-312M(K) GX-312ML(K) +0.5 0 +0.0197 0 ø12.5 ø0.492 17 0.669 GX-318M(K) GX-318ML(K) ø18.5+0.5 0 ø0.728+0.0197 0 24 0.945 GX-330M(K) GX-330ML(K) ø30.5+0.5 0 ø1.201+0.0197 0 36 1.417 Mounting hole Mounting • The tightening torque should be under the value given below. Installation using set screw • Do not tighten the product mounting nuts with excessive force. Tr A E Bending radius of lead-out cable section Set screw (M3), cup point (Set screw is not provided with the product. It must be arranged by the customer.) Model No. GX-303S GX-304S GX-305S GX-305M 10 mm 0.394 in or more R Model No. Set screw location A (mm in) Tightening torque GX-303S GX-304S GX-305S 13 to 21 0.512 to 0.827 0.2 N∙m 8 to 21 0.315 to 0.827 0.4 N∙m Installation using nut • Do not tighten the nut with excessive force. Be sure to install the toothed locked washer. • In the case of the M8 threaded type, the allowable strength differs depending on the distance from the tip of the head. The following table shows the allowable tightening strengths for section B and section C shown in the diagram. (Section B starts from the tip of the head and its dimension is indicated in the table. Section C includes the nut on the head side. Therefore, if the nut extends into section B even slightly, the strength of section B is applicable.) • The following allowable tightening strengths are applicable when the washer is installed. Shielded type, threaded type Attached toothed lock washer C Model No. (Shielded type) GX-305M GX-308M(K) GX-312M(K) GX-318M(K) GX-330M(K) Model No. (Non-shielded type) GX-308ML(K) GX-312ML(K) GX-318ML(K) GX-330ML(K) Non-shielded type, threaded type Attached toothed lock washer B C B Dimension (mm in) Tightening torque - 1 N∙m 9 0.354 9 N∙m - • Please use the sensor after confirming the installation distance by following (a) and (b) with an actual detection object when you install. (a)The detection distance receives the influence by the material of the detection object, thickness, shape, and the size. So, the detection object is brought close to the front side of the sensor and detection distance (S) is measured. For the effect of the material, see the graph, “Correlation between sensing object size and sensing range,” (p.16). (b)Please decide installation distance (Sa) with S × 70% or less after measuring sensing distance(S). • Please install the sensor to come within the range of (Sa) when the detection object moves from vertical direction. • Please install the sensor to pass within the range of (Sa) when the detection object moves from horizontal direction. • When using the sensor, refer to the “Standard sensing object” specified in the specifications (p.10) and the graph, “Correlation between sensing object size and sensing range,” (p.16). S (a) (b) Sa Sa = S × 0.7 12 N∙m 30 N∙m - 70 N∙m - 180 N∙m Dimension (mm in) B Tightening torque C Tightening torque 3 0.118 9 N∙m 12 N∙m - 9 mm 0.354 in or more Installing small-diameter sensor B C Tightening torque Bending radius R 7 mm 0.276 in or more 30 N∙m - 70 N∙m - 180 N∙m 21 GX-300 PRECAUTIONS FOR PROPER USE Distance from surrounding metal Mutual interference • As metal around the sensor may affect the sensing performance, pay attention to the following points. • When two or more sensors are installed in parallel or face to face, keep the minimum separation distance specified below to avoid mutual interference Influence of surrounding metal • The surrounding metal will affect the sensing performance. Keep the minimum distance specified in the table below. • When mounting the sensor using a nut, use the nut and washer provided with the product. • The type of the provided nut varies in different models. See the external dimensions diagrams (p.23~) for the detail of the shape. Mounting method A (Using the provided nut) F F H G H I F Mounting method B (Embedded in the metal) J J K H G H I (Unit: mm in) Model No. (Shielded type) F G H I J GX-303S - - - - 0 GX-304S - - - - 0 GX-305S - - - - 0 GX-305M 0 GX-308M 0 GX-312M 0 GX-318M 0 ø5 ø0.197 ø8 ø0.315 ø12 ø0.472 ø18 ø0.709 ø30 ø1.181 ø8 ø0.315 ø18 ø0.709 ø27 ø1.063 ø45 ø1.772 5 0.197 4.5 0.177 8 0.315 20 0.787 40 1.575 4.5 0.177 12 0.472 24 0.945 45 1.772 10 0.394 12 0.472 18 0.709 27 1.063 45 1.772 12 0.472 18 0.709 27 1.063 45 1.772 GX-330M 0 GX-308MK 0 GX-312MK 0 GX-318MK 0 GX-330MK 0 Model No. (Non-shielded type) GX-308ML GX-312ML GX-318ML GX-330ML GX-308MLK GX-312MLK GX-318MLK GX-330MLK 22 Mounting method A Mounting method B G 0 0 0 0 0 0 2.4 0.094 3.6 0.142 6 0.236 Mounting method A ø3 ø0.118 ø4 ø0.157 ø5.4 ø0.213 ø5 ø0.197 ø8 ø0.315 ø12 ø0.472 ø18 ø0.709 ø30 ø1.181 ø8 ø0.315 ø18 ø0.709 ø27 ø1.063 ø45 ø1.772 K 0 0 0 0 0 0 0 0 0 2.4 0.094 3.6 0.142 6 0.236 H I 3 0.118 5 0.197 3 0.118 5 0.197 4.5 0.177 8 0.315 20 0.787 40 1.575 4.5 0.177 12 0.472 24 0.945 45 1.772 8 0.315 10 0.394 8 0.315 10 0.394 12 0.472 18 0.709 27 1.063 45 1.772 12 0.472 18 0.709 27 1.063 45 1.772 Mounting method B F G H I J G K H I 6 0.236 11 0.433 18 0.709 25 0.984 9 0.354 11 0.433 21 0.827 40 1.575 ø24 ø0.945 ø40 ø1.575 ø55 ø2.165 ø90 ø3.543 ø24 ø0.945 ø40 ø1.575 ø70 ø2.756 ø120 ø4.724 8 0.315 20 0.787 40 1.575 70 2.756 8 0.315 20 0.787 48 1.890 90 3.543 24 0.945 36 1.417 54 2.126 90 3.543 24 0.945 40 1.575 70 2.756 120 4.724 6 0.236 15 0.591 22 0.866 30 1.181 12 0.472 15 0.591 25 0.984 45 1.772 ø24 ø0.945 ø40 ø1.575 ø55 ø2.165 ø90 ø3.543 ø24 ø0.945 ø40 ø1.575 ø70 ø2.756 ø120 ø4.724 6 0.236 15 0.591 22 0.866 30 1.181 12 0.472 15 0.591 25 0.984 45 1.772 8 0.315 20 0.787 40 1.575 70 2.756 8 0.315 20 0.787 48 1.890 90 3.543 24 0.945 36 1.417 54 2.126 90 3.543 24 0.945 40 1.575 70 2.756 120 4.724 L L M Model No. (Shielded type) GX-303S GX-304S GX-305S GX-305M GX-308M(K) GX-312M(K) GX-318M GX-318MK GX-330M GX-330MK Model No. (Non-shielded type) GX-308ML(K) GX-312ML(K) GX-318ML GX-318MLK GX-330ML GX-330MLK L (mm in) M (mm in) 20 0.787 15 0.591 20 0.787 15 0.591 20 0.787 15 0.591 20 0.787 15 0.591 20 0.787 15 0.591 30 1.181 20 0.787 50 1.969 35 1.378 60 2.362 35 1.378 100 3.937 70 2.756 110 4.331 90 3.543 L (mm in) M (mm in) 80 3.150 60 2.362 120 4.724 100 3.937 200 7.874 110 4.331 200 7.874 120 4.724 300 11.811 200 7.874 350 13.780 300 11.811 Timing chart Non-sensing area Operation Sensing object Mode (%) N.O. Standard I/O mode (SIO) (Note 1) N.C. N.O. IO-Link communication mode (COM) (Note 2) N.C. 100 Sensing area Proximity Sensor 0 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF Flashing (1 sec cycle) ON OFF ON OFF Flashing (1 sec cycle) ON OFF ON OFF Communication indicator (Green) Operation indicator (Orange) OUT Communication indicator (Green) Operation indicator (Orange) OUT Communication indicator (Green) Operation indicator (Orange) OUT Communication indicator (Green) Operation indicator (Orange) OUT Notes: 1) When sensors that are not compatible with IO-Link are used or when IO-Link compatible models are used as ordinary sensors, they operate in the standard I/O mode (SIO mode). 2) The operation mode can be changed by the IO-Link communications. The timer function of the output can be set up by the IO-Link communications. GX-300 PRECAUTIONS FOR PROPER USE Others • This product has been developed / produced for industrial use only. • Do not install the product in the following locations. Doing so may result in product failure or malfunction. ∙ Outdoor locations directly subject to sunlight, rain, snow, water droplets, or oil. ∙ Locations subject to atmospheres with chemical vapors, in particular solvents and acids. ∙ Locations subject to corrosive gases. • The product may malfunction if used near ultrasonic cleaning equipment, high-frequency equipment, transceivers, cellular phones, inverters, or other devices that generate a high-frequency electric field. • Laying the product wiring in the same conduit or duct as high-voltage wires or power lines may result in incorrect operation and damage due to induction. Wire the product using a separate conduit or independent conduit. • The following conditions shall be observed if you use the product under an environment using cutting oil that may affect product’s life and/or performance. ∙ Usage in oil or water is prohibited. • Impact on the product life may differ depending on the oil you use. Before using the cutting oil, make sure that it should not cause deterioration or degradation of sealing components. • Never use thinner or other solvents. Otherwise, the product surface may be dissolved. • When turning ON the power by influence of temperature environment, an output mis-pulse sometimes occurs. After the product has passed for 300 ms after turning ON, please use in the stable state. If the sensing object is located near the sensor’s sensing surface, an output mis-pulse may be generated for 300 ms or longer at the time of power-on. Be sure to check the product for proper operation under actual operating condition before using. • The product is adjusted with a high degree of accuracy, so do not use in the environment with sudden temperature change. • Do not attempt to disassemble, repair, or modify the product. • Do not use a voltage that exceeds the rated operating voltage range. Applying a voltage that is higher than the operating voltage range may result in damage or burnout. • Be sure that the power supply polarity and other wiring is correct. Incorrect wiring may cause explosion or burnout. • If the power supply is connected directly without a load, the internal elements may explode or burn. Be sure to insert a load when connecting the power supply. • Please use gloves to protect yourself from injury caused by screw. • For the connector type and pigtailed type, check the specifications of the connector cable to be used. Please do not use it under conditions that exceed the range of its specifications of both the product and the connector cable. • Please make sure there is no foreign matter in connector part before connecting the connector cable to the connector type and pigtailed type. • In the IO-Link mode, the cable between the IO-Link master and sensor must have a length of 20 m 65.617 ft or less. DIMENSIONS(Unit: mm in) Sensor 27.1 1.067 18 0.709 Operation indicator (orange), 4 locations on circumference GX-304S-□ Sensor 25.1 0.988 0 ø4 -0.1 0 ø0.157 -0.004 0 ø3 -0.1 0 ø0.118 -0.004 GX-303S-□ The CAD data can be downloaded from our website. Operation indicator (orange), 4 locations on circumference 18.5 0.728 ø2.4 mm ø0.094 in cable, 2 m 6.562 ft long (Products with “-C5” at the end of model No.: 5 m 16.404 ft) GX-305S-□ Sensor ø2.9 mm ø0.114 in cable, 2 m 6.562 ft long (Products with “-C5” or “-R5” at the end of model No.: 5 m 16.404 ft) GX-305M-□ Sensor 0 ø5.4 -0.1 0 ø0.213 -0.004 25.1 0.988 25.1 0.988 18.5 0.728 Operation indicator (orange), 4 locations on circumference ø10 ø0.394 8 0.315 18.5 0.728 0.6 0.024 15.1 0.594 4 1 0.157 0.039 Operation indicator (orange), 4 locations on circumference ø2.9 mm ø0.114 in cable, 2 m 6.562 ft long (Products with “-C5” or “-R5” at the end of model No.: 5 m 16.404 ft) ø2.9 mm ø0.114 in cable, 2 m 6.562 ft long (Products with “-C5” or “-R5” at the end of model No.: 5 m 16.404 ft) 3 0.118 M5 × 0.5 0.020 Toothed lock washer (Internally toothed) 23 DIMENSIONS(Unit: mm in) The CAD data can be downloaded from our website. GX-308M(K)-□   GX-312M(K)-□   GX-318M(K)-□   GX-330M(K)-□ GX-308ML(K)-□   GX-312ML(K)-□   GX-318ML(K)-□   GX-330ML(K)-□ Cable type / Pigtailed type Sensor Connector type B B D F E J Operation indicator (orange), 4 locations on circumference IO-Link communication indicator [green, flashing (1-sec intervals)] D C G G M8, M12 sizes: ø4 mm ø0.157 in cable, 2 m 6.562 ft long M18, M30 sizes: ø6 mm ø0.236 in cable, 2 m 6.562 ft long (Products with “-C5” or “-R5” at the end of model No.: 5 m 16.404 ft) A F E J < Cable type > C A I I Operation indicator (orange) IO-Link communication indicator [green, flashing (1-sec intervals)] H H Toothed lock washer (Internally toothed) Toothed lock washer (Internally toothed) < Pigtailed type > Cable length: 0.3 m 0.984 ft Symbol Model No. GX-308M(K) GX-312M(K) GX-318M(K) GX-330M(K) Symbol Model No. M12 × 1 0.039 A B C M8 × 1 M8 × 0.039 M12 × 1 M12 × 0.039 M18 × 1 M18 × 0.039 M30 × 1.5 M30 × 0.059 37.8 1.488 47.1 1.854 55.3 2.177 60.3 2.374 4.4 0.173 3.7 0.146 8.5 0.335 8.3 0.327 A M8 × 1 M8 × 0.039 M12 × 1 GX-312ML(K) M12 × 0.039 M18 × 1 GX-318ML(K) M18 × 0.039 M30 × 1.5 GX-330ML M30 × 0.059 M30 × 1.5 GX-330MLK M30 × 0.059 GX-308ML(K) B 37.8 1.488 47.1 1.854 55.3 2.177 60.3 2.374 82.3 3.240 Shielded type D E F G 26 1.024 33 1.299 38 1.496 43 1.693 - 10 0.394 12 0.472 12 0.472 12 0.472 4 0.157 4 0.157 4 0.157 4 0.157 Non-shielded type C D E F G 4.4 26 6 8 0.173 1.024 0.236 0.315 3.7 33 7 10 0.146 1.299 0.276 0.394 8.5 38 10 10 0.335 1.496 0.394 0.394 8.3 43 13 10 0.327 1.693 0.512 0.394 8.3 65 15 10 0.327 2.559 0.591 0.394 - H I J 3 0.118 4 0.157 4 0.157 5 0.197 15 0.591 21 0.827 29 1.142 42 1.654 13 0.512 17 0.669 24 0.945 36 1.417 H I J 3 15 13 0.118 0.591 0.512 4 21 17 0.157 0.827 0.669 4 29 24 0.157 1.142 0.945 5 42 36 0.197 1.654 1.417 5 42 36 0.197 1.654 1.417 Symbol Model No. GX-312M(K) GX-318M(K) GX-330M(K) Symbol Model No. A B M12 × 1 M12 × 0.039 M18 × 1 M18 × 0.039 M30 × 1.5 M30 × 0.059 C Shielded type D E F 48 M12 × 1 1.890 M12 × 0.039 53 M12 × 1 2.087 M12 × 0.039 58 M12 × 1 2.283 M12 × 0.039 33 1.299 38 1.496 43 1.693 G H I J 12 4 4 21 17 0.472 0.157 0.157 0.827 0.669 12 4 4 29 24 0.472 0.157 0.157 1.142 0.945 12 4 5 42 36 0.472 0.157 0.197 1.654 1.417 - Non-shielded type C D E F G A B M12 × 1 48 M12 × 1 33 7 10 M18 × 1 53 M12 × 1 38 10 10 H I J 4 21 17 GX-312ML(K) M12 × 0.039 1.890 M12 × 0.039 1.299 0.276 0.394 - 0.157 0.827 0.669 4 29 24 GX-318ML(K) M18 × 0.039 2.087 M12 × 0.039 1.496 0.394 0.394 - 0.157 1.142 0.945 GX-330ML GX-330MLK M30 × 1.5 58 M12 × 1 M30 × 0.059 2.283 M12 × 0.039 M30 × 1.5 80 M12 × 1 M30 × 0.059 3.150 M12 × 0.039 43 13 10 1.693 0.512 0.394 65 15 10 2.559 0.591 0.394 - 5 42 36 0.197 1.654 1.417 5 42 36 0.197 1.654 1.417 Note: M8 type models are not available in the connector type. Please contact .......... Industrial Device Business Division 7-1-1, Morofuku, Daito-shi, Osaka 574-0044, Japan industrial.panasonic.com/ac/e/ ©Panasonic Corporation 2020 No.CE-GX300-6 November, 2020 Specifications are subject to change without notice.
GX-308M-B-N-J 价格&库存

很抱歉,暂时无法提供与“GX-308M-B-N-J”相匹配的价格&库存,您可以联系我们找货

免费人工找货
GX-308M-B-N-J
  •  国内价格 香港价格
  • 1+657.275411+82.25107
  • 5+608.662285+76.16765
  • 10+590.5284610+73.89840
  • 25+568.8470925+71.18520
  • 50+553.9981050+69.32701
  • 100+540.37591100+67.62233

库存:2

GX-308M-B-N-J
    •  国内价格
    • 1+274.97880
    • 200+109.71720
    • 500+106.05600
    • 1000+104.24160

    库存:0