0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
GX-M18B-P

GX-M18B-P

  • 厂商:

    NAIS(松下)

  • 封装:

    Cylinder,Threaded-M18

  • 描述:

    SENSOR PROX INDUCTIVE 4MM CYLIND

  • 数据手册
  • 价格&库存
GX-M18B-P 数据手册
817 Cylindrical Inductive Proximity Sensor GX-M SERIES Related Information FIBER SENSORS ■■General terms and conditions.............. F-3 ■■Glossary of terms........................P.1576~ Amplifier Built-in ■■Selection guide.............................. P.781~ ■■General precautions.................... P.1579~ LASER SENSORS PHOTOELECTRIC SENSORS Listing (2 m cable length type only) MICRO PHOTOELECTRIC SENSORS Features AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS panasonic.net/id/pidsx/global WIRE-SAVING SYSTEMS • Wide product range Types: D  C 3-wire shielded type DC 3-wire non-shielded type DC 2-wire standard type DC 2-wire long range type Size: M8, M12, M18, M30 Connector: 2  m (6.56 ft) cable length type M12 plug-in connector type M12 pigtailed type (DC 2-wire M8 type only) • Strong resistance IP68 (GX-M8□: IP67) MEASUREMENT SENSORS Type GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX Sensing range (Note 1,2) Max. operation distance: 2 mm 0.08 in (Stable sensing range 0 to 1.6 mm 0.06 in) Max. operation distance: 5 mm 0.20 in (Stable sensing range 0 to 4 mm 0.16 in) M30 Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in) Ex.) GX-M12□ Max. operation distance: 10 mm 0.39 in (Stable sensing range 0 to 8 mm 0.32 in) Max. operation distance: 7 mm 0.28 in (Stable sensing range 0 to 5.6 mm 0.22 in) Max. operation distance: 12 mm 0.47 in (Stable sensing range 0 to 9.6 mm 0.38 in) M30 Selection Guide Amplifier Built-in Amplifierseparated Other Products Non-shielded UV CURING SYSTEMS Shielded MACHINE VISION SYSTEMS Appearance M8 FA COMPONENTS DC 3-wire type (2 m cable length type) M12 ENERGY MANAGEMENT SOLUTIONS M18 HUMAN MACHINE INTERFACES Metal embedding possible ORDER GUIDE PLC M12 LASER MARKERS Oil resistant 2-wire type PNP output type available available Large selection M18 STATIC CONTROL DEVICES Ex.) GX-MK12□ Max. operation distance: 22 mm 0.87 in (Stable sensing range 0 to 17.6 mm 0.69 in) Model No. NPN output PNP output Output operation GX-M8A GX-M8A-P Normally open GX-M8B GX-M8B-P Normally closed GX-M12A GX-M12A-P Normally open GX-M12B GX-M12B-P Normally closed GX-M18A GX-M18A-P Normally open GX-M18B GX-M18B-P Normally closed GX-M30A GX-M30A-P Normally open GX-M30B GX-M30B-P Normally closed GX-MK12A GX-MK12A-P Normally open GX-MK12B GX-MK12B-P Normally closed GX-MK18A GX-MK18A-P Normally open GX-MK18B GX-MK18B-P Normally closed GX-MK30A GX-MK30A-P Normally open GX-MK30B GX-MK30B-P Normally closed Notes: 1) It is the value in state where the circumference of a detection side has a metal object. 2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. Cylindrical Inductive Proximity Sensor GX-M SERIES ORDER GUIDE FIBER SENSORS LASER SENSORS DC 2-wire type (2 m cable length type) PHOTOELECTRIC SENSORS GX-M8A-U Normally open MICRO PHOTOELECTRIC SENSORS GX-M8B-U Normally closed GX-M12A-U Normally open GX-M12B-U Normally closed GX-M18A-U Normally open GX-M18B-U Normally closed GX-M30A-U Normally open GX-M30B-U Normally closed GX-ML8A-U Normally open GX-ML8B-U Normally closed GX-ML12A-U Normally open GX-ML12B-U Normally closed GX-ML18A-U Normally open GX-ML18B-U Normally closed GX-ML30A-U Normally open GX-ML30B-U Normally closed M8 Max. operation distance: 5 mm 0.20 in (Stable sensing range 0 to 4 mm 0.16 in) M30 Max. operation distance: 2 mm 0.08 in (Stable sensing range 0 to 1.6 mm 0.06 in) Max. operation distance: 10 mm 0.39 in (Stable sensing range 0 to 8 mm 0.32 in) M8 M12 Model No. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in) Max. operation distance: 2.5 mm 0.10 in (Stable sensing range 0 to 2 mm 0.08 in) Ex.) GX-M12□-U Max. operation distance: 4 mm 0.16 in (Stable sensing range 0 to 3.2 mm 0.13 in) M18 M12 Output operation Sensing range (Note 1,2) M18 Appearance Max. operation distance: 8 mm 0.32 in (Stable sensing range 0 to 6.4 mm 0.25 in) M30 Long range Standard Type 818 Max. operation distance: 15 mm 0.59 in (Stable sensing range 0 to 12 mm 0.47 in) Notes: 1) It is the value in state where the circumference of a detection side has a metal object. 2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES M12 plug-in connector type (except for GX-M8□-U and GX-ML8□-U) ENERGY MANAGEMENT SOLUTIONS M12 plug-in connector type is also available. When ordering this type, suffix “-Z” for the M12 plug-in connector type to the model No. (e.g.) M12 plug-in connector type of GX-M8A-P is “GX-M8A-P-Z”. FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS M12 pigtailed type (for GX-M8□-U and GX-ML8□-U only) M12 pigtailed type is also available. When ordering this type, suffix “-J” for the M12 pigtailed type to the model No. (e.g.) M12 pigtailed type of GX-M8A-U is “GX-M8A-U-J”. Selection Guide Amplifier Built-in Amplifierseparated Other Products Mating cable • Mating cable For M12 plug-in connector type Type Straight Elbow Model No. Description CN-24C-C2 Length: 2 m 6.56 ft CN-24C-C5 Length: 5 m 16.40 ft Clamping ring : ø14mm 0.55 in CN-24CL-C2 Length: 2 m 6.56 ft CN-24CL-C5 Length: 5 m 16.40 ft Cable outer : ø5.3mm 0.21 in • Straight type • Elbow type GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX 819 Cylindrical Inductive Proximity Sensor SPECIFICATIONS FIBER SENSORS LASER SENSORS DC 3-wire type PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Item Normally open GX-M12A□ GX-M18A□ GX-M30A□ GX-MK12A□ GX-MK18A□ GX-MK30A□ Normally closed GX-M8B□ GX-M12B□ GX-M18B□ GX-M30B□ GX-MK12B□ GX-MK18B□ GX-MK30B□ CE marking directive compliance Stable sensing range (Note 2,3) Standard sensing object ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 5 mm 0.20 in ±10 % 10 mm 0.39 in ±10 % 7 mm 0.28 in ±10 % 12 mm 0.47 in ±10 % 22 mm 0.87 in ±10 % 0 to 1.2 mm 0 to 0.05 in 0 to 1.6 mm 0 to 0.06 in 0 to 4 mm 0 to 0.16 in 0 to 8 mm 0 to 0.32 in 0 to 5.6 mm 0 to 0.22 in 0 to 9.6 mm 0 to 0.38 in 0 to 17.6 mm 0 to 0.69 in Iron sheet 8 × 8 × t 1 mm 0.32 × 0.32 × t 0.04 in Iron sheet 12 × 12 × t 1 mm 0.47 × 0.47 × t 0.04 in Iron sheet 18 × 18 × t 1 mm 0.71 × 0.71 × t 0.04 in Iron sheet 30 × 30 × t 1 mm 1.18 × 1.18 × t 0.04 in Iron sheet 24 × 24 × t 1 mm 0.94 × 0.94 × t 0.04 in Iron sheet 24 × 24 × t 1 mm 0.94 ×0.94 × t 0.04 in Iron sheet 45 × 45 × t 1 mm 1.77 × 1.77 × t 0.04 in 15 % or less of operation distance (with standard sensing object) Repeatability (Note 2) Along sensing axis: 5 % or less of operation distance Supply voltage 12 to 24 V DC ±10 %   Ripple P-P 10 % or less Current consumption 10 mA or less NPN open-collector transistor • Maximum sink current 200 mA • Applied voltage: 24 V DC or less (between output and 0 V) • Residual voltage 2 V or less Output Incorporated Short-circuit protection Max. response frequency 5 kHz 5 kHz Operation indicator IP67 (IEC) Voltage withstandability 500 V AC for one min. between all supply terminals connected together and enclosure 10 to 55 Hz frequency, 0.5 mm 0.02 in double amplitude in X, Y and Z directions for 1.5 hours each 294 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each Shock resistance Within ±10 % fluctuation of sensing range at +23 °C +73 °F and rated voltage in the range of allowable temperature and supply voltage Enclosure: Brass (Nickel plated), Sensing part: PPS Selection Guide Cable extension Amplifier Built-in Net weight (Note 4) GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX 0.5 kHz 50 % RH or less (at +70 °C +158 °F) Material Other Products 1 kHz –25 to +70 °C –13 to +158 °F, Storage: –40 to +85 °C –40 to +185 °F 0.44 mm2 (0.15 mm2 for GX-M8□) 3-core cabtyre cable, 2 m 6.56 ft long Cable (except for M12 plug-in connector type) Amplifierseparated 2.5 kHz IP69K (DIN), IP68 (IEC) (2 m cable length type only) , IP67 (IEC) (M12 plug-in connector type only) Ambient humidity Sensing range variation (Note 2) 1 kHz 3 (industrial enviroment) Ambient temperature Vibration resistance 2 kHz Yellow LED (lights up when the output is ON) Pollution degree Protection PNP open-collector transistor • Maximum source current 200 mA • Applied voltage: 24 V DC or less (between output and + V) • Residual voltage 2 V or less DC-12 or DC-13 Utilization category Environmental resistance HUMAN MACHINE INTERFACES 2 mm 0.08 in ±10 % Hysteresis (Note 2) STATIC CONTROL DEVICES PLC EMC Directive, RoHS Directive Max. operation distance (Note 2,3) 1.5 mm 0.06 in ±10 % MEASUREMENT SENSORS LASER MARKERS Non-shielded type GX-M8A□ SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Shielded type Type Model No. MICRO PHOTOELECTRIC SENSORS GX-M SERIES Extension up to total 10 m 32.80 ft is possible with 0.34 mm2, or more, cable. 2 m cable length type 40 g approx. 70 g approx. 90 g approx. 150 g approx. 75 g approx. 100 g approx. 180 g approx. M12 plug-in connector type 15 g approx. 20 g approx. 45 g approx. 110 g approx. 25 g approx. 55 g approx. 140 g approx. Accessories Nut: 2 pcs. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) It is the value in state where the circumference of a detection side has a metal object. 3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 4) The weight includes the weight of two nuts. Cylindrical Inductive Proximity Sensor GX-M SERIES SPECIFICATIONS FIBER SENSORS LASER SENSORS DC 2-wire type Standard type Model No. Type Item Long range type Normally open GX-M8A-U(-J) GX-M12A-U(-Z) GX-M18A-U(-Z) GX-M30A-U(-Z) GX-ML8A-U(-J) GX-ML12A-U(-Z) GX-ML18A-U(-Z) GX-ML30A-U(-Z) Normally closed GX-M8B-U(-J) GX-M12B-U(-Z) GX-M18B-U(-Z) GX-M30B-U(-Z) GX-ML8B-U(-J) GX-ML12B-U(-Z) GX-ML18B-U(-Z) GX-ML30B-U(-Z) CE marking directive compliance EMC Directive, RoHS Directive Max. operation distance (Note 2,3) 1.5 mm 0.06 in ±10 % 2 mm 0.08 in ±10 % Stable sensing range (Note 2,3) Standard sensing object 5 mm 0.20 in ±10 % 10 mm 0.39 in ±10 % 2.5 mm 0.10 in ±10 % 4 mm 0.16 in ±10 % 0 to 4 mm 0 to 0.09 in 0 to 8 mm 0 to 0.22 in 0 to 2 mm 0 to 0.08 in 0 to 3.2 mm 0 to 0.13 in 0 to 6.4 mm 0 to 0.25 in 0 to 12 mm 0 to 0.47 in Iron sheet 8 × 8 × t 1 mm 0.32 × 0.32 × t 0.04 in Iron sheet 12 × 12 × t 1 mm 0.47 × 0.47 × t 0.04 in Iron sheet 18 × 18 × t 1mm 0.71 × 0.71 × t 0.04 in Iron sheet 30 × 30 × t 1 mm 1.18 × 1.18 × t 0.04 in Iron sheet 8 × 8 × t 1 mm 0.32 × 0.32 × t 0.04 in Iron sheet 12 × 12 × t 1 mm 0.47 × 0.47 × t 0.04 in Iron sheet 18 × 18 × t 1 mm 0.71 × 0.71 × t 0.04 in Iron sheet 30 × 30 × t 1 mm 1.18 × 1.18 × t 0.04 in 15 % or less of operation distance (with standard sensing object) Supply voltage 12 to 24 V DC ±10 %   Ripple P-P 10 % or less Max. response frequency 1 kHz 1.2 kHz Operation indicator 1.3 kHz 1.3 kHz 1.5 kHz 0.8 kHz IP67 (IEC) IP69K (DIN), IP68 (IEC) (2 m cable length type only) , IP67 (IEC) (M12 plug-in connector type only) –25 to +70 °C –13 to +158 °F, Storage: –40 to +85 °C –40 to +185 °F Ambient humidity 500 V AC for one min. between all supply terminals connected together and enclosure Vibration resistance 10 to 55 Hz frequency, 0.5 mm 0.02 in double amplitude in X, Y and Z directions for 1.5 hours each 294 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each Shock resistance FA COMPONENTS UV CURING SYSTEMS Enclosure: Brass (Nickel plated), Sensing part: PPS 0.44 mm2 [0.15 mm2 for GX-M(L)8□-U] 2-core cabtyre cable, 2 m 6.56 ft long Cable (except for M12 plug-in connector type) Cable extension Extension up to total 10 m 32.80 ft is possible with 0.34 mm2, or more, cable. 2 m cable length type 40 g approx. 70 g approx. 90 g approx. 150 g approx. 40 g approx. 70 g approx. 90 g approx. 150 g approx. M12 pigtailed(-J type) / M12 plug-in connector type 20 g approx. 20 g approx. 45 g approx. 110 g approx. 20 g approx. 20 g approx. 45 g approx. 110 g approx. Accessories ENERGY MANAGEMENT SOLUTIONS MACHINE VISION SYSTEMS Within ±10 % fluctuation of sensing range at +23 °C +73 °F and rated voltage in the range of allowable temperature and supply voltage Material PLC HUMAN MACHINE INTERFACES 50 % RH or less (at +70 °C +158 °F) Voltage withstandability STATIC CONTROL DEVICES LASER MARKERS 3 (Industrial environment) Ambient temperature Sensing range variation (Note 2) 1.1 kHz Yellow LED (lights up when the output is ON) Pollution degree Protection MEASUREMENT SENSORS Incorporated 1 kHz INDUCTIVE PROXIMITY SENSORS WIRE-SAVING SYSTEMS DC-12 or DC-13 Utilization category PRESSURE / FLOW SENSORS SIMPLE WIRE-SAVING UNITS Non-contact DC 2-wire type • Load current: 1.5 to 100 mA • Residual voltage: 4.2 V or less (Note 5) Short-circuit protection SAFETY LIGHT CURTAINS / SAFETY COMPONENTS SENSOR OPTIONS 0.5 mA or less Output MICRO PHOTOELECTRIC SENSORS PARTICULAR USE SENSORS Along sensing axis: 5 % or less of operation distance Current consumption (Note 4) Environmental resistance 8 mm 0.32 in ±10 % 15 mm 0.59 in ±10 % 0 to 1.6 mm 0 to 0.06 in Repeatability (Note 2) PHOTOELECTRIC SENSORS AREA SENSORS 0 to 1.2 mm 0 to 0.05 in Hysteresis (Note 2) Net weight (Note 6) 820 Nut: 2 pcs. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) It is the value in state where the circumference of a detection side has a metal object. 3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 4) It is the leakage current when the output is in the OFF state. 5) When the cable is extended, the residual voltage becomes larger. 6) The weight includes the weight of two nuts. Selection Guide Amplifier Built-in Amplifierseparated Other Products GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX 821 FIBER SENSORS LASER SENSORS GX-M SERIES Cylindrical Inductive Proximity Sensor WIRING DIAGRAMS DC 3-wire type PHOTOELECTRIC SENSORS Wiring diagrams MICRO PHOTOELECTRIC SENSORS NPN output type PNP output type (Brown) +V AREA SENSORS (Brown) +V Load SAFETY LIGHT CURTAINS / SAFETY COMPONENTS + (Black) Output – (Black) Output 12 to 24V DC ±10 % – Load PRESSURE / FLOW SENSORS (Blue) 0 V (Blue) 0 V INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Connector pin position M12 connector 4 3 1 2 • Normally Open 1 : +V 2 : Not connected 3:0V 4 : Output • Normally Closed 1 : +V 2 : Output 3:0V 4 : Not connected WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS DC 2-wire type Wiring diagrams (Brown) +V PLC – ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated Other Products GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX Load + HUMAN MACHINE INTERFACES (Blue) 0 V 12 to 24V DC ±10 % Load Connector pin position M12 connector 4 3 1 2 • Normally Open • Normally Closed 1 : +V (except for GX-M8□-U-J and GX-ML8□-U-J) 1 : Not connected 2 : Not connected 3 : +V 4:0V • Normally Open (GX-M8□-U-J and GX-ML8□-U-J only) 1 : +V 2 : Not connected 3 : Not connected 4:0V + 2:0V 3 : Not connected 4 : Not connected 12 to 24V DC ±10 % Cylindrical Inductive Proximity Sensor PRECAUTIONS FOR PROPER USE GX-M SERIES 822 Refer to p.1579~ for general precautions. • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. LASER SENSORS Embedding of the sensor in metal • Sensing range may decrease if the sensor is completely embedded in metal. Especially for the non-shielded type, keep the minimum distance specified in the right table. Sensor B C size (mm in) (mm in) % Mounting • The tightening torque should be under the value given below. & M12 12 0.47 12 0.47 M18 18 0.71 18 0.71 M30 30 1.18 30 1.18 Note: With the non-shielded type, the sensing range may vary depending on the position of the nuts. 0HWDO • When two or more sensors are installed in parallel or face to face, keep the minimum separation distance specified below to avoid mutual interference. Face to face mounting Model No. GX-M□ GX-M(L)8□-U-J Sensor Connector (Note) M8 5 N·m 2 N·m M12 6 N·m 2 N·m M18 15 N·m 2 N·m M30 40 N·m 2 N·m M8 5 N·m 1.5 N·m Note: Connector is equipped with -Z type or -J type. • As metal around the sensor may affect the sensing performance, pay attention to the following points. Background metal • The surrounding metal will affect the sensing performance. Keep the minimum distance specified in the table below. A A (mm in) M8 M12 M18 M30 3 0.12 4 0.16 10 0.39 20 0.79 - 21 0.83 36 1.42 66 2.60 DC 2-wire standard type 4.5 0.18 6 0.23 15 0.59 30 1.18 DC 2-wire long range type 8 0.32 12 0.47 25 0.98 45 1.77 DC 3-wire non-shielded type DC 3-wire shielded type D (mm in) M8 M12 M18 M30 E (mm in) M8 M12 M18 M30 18 24 60 120 3 4 10 20 0.71 0.94 2.36 4.72 0.12 0.16 0.39 0.77 AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS STATIC CONTROL DEVICES LASER MARKERS PLC 48 72 120 1.89 2.83 4.72 HUMAN MACHINE INTERFACES 18 24 60 120 3 4 10 20 0.71 0.94 2.36 4.72 0.12 0.16 0.39 0.77 ENERGY MANAGEMENT SOLUTIONS 50 100 180 5 8 16 30 DC 2-wire long 30 1.18 1.97 3.93 7.09 0.20 0.32 0.63 1.18 range type FA COMPONENTS DC 3-wire non-shielded type - 84 144 264 3.30 5.67 10.39 Wiring Influence of surrounding metal DC 3-wire shielded type Type MICRO PHOTOELECTRIC SENSORS MEASUREMENT SENSORS E DC 2-wire standard type Distance from surrounding metal Type Parallel mounting D Sensor size PHOTOELECTRIC SENSORS PARTICULAR USE SENSORS Mutual interference Tightening torque FIBER SENSORS • Make sure that the power supply is off while wiring. • Verify that the supply voltage variation is within the rating. • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. • Ensure that an isolation transformer is utilized for the DC power supply. If an autotransformer is utilized, the main body or power supply may be damaged. • If the used power supply generates a surge, connect a surge absorber to the power supply to absorb the surge. • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. • Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. • Damage or burnout may result in case of short circuit of load or miswiring. • Make a cable length as short as possible to lessen noise pickup. MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated Other Products GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX 823 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Cylindrical Inductive Proximity Sensor PRECAUTIONS FOR PROPER USE • Our products have been developed / produced for industrial use only. • Avoid using a product where there is excessive vapor, dust or corrosive gas, or in a place where it could be exposed directly to water or chemicals. • Take care that the sensor does not come in direct contact with water, oil, grease or organic solvents, such as, thinner, etc. • Do not use in an environment containing inflammable or explosive gases. • Never disassemble or modify the product. DIMENSIONS (Unit: mm in) Sensors b a /(' HUMAN MACHINE INTERFACES E ENERGY MANAGEMENT SOLUTIONS D FA COMPONENTS LED GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX b a b GX-M8□ 33 1.30 25 0.98 45 1.77 24 0.94 M12 GX-M12□ 35 1.38 25 0.98 50 1.97 30 1.18 M18 GX-M18□ 39 1.54 28 1.10 50 1.97 28 1.10 M30 GX-M30□ 43 1.69 32 1.26 55 2.17 32 1.26 Sensors 2 m cable length type (mm in) Non-shielded type a b c a b M12 plug-in connector type (mm in) c M12 GX-MK12□ 55 2.17 42 1.65 5 0.20 66 2.60 42 1.65 5 0.20 M18 GX-MK18□ 60 2.36 44 1.73 8 0.32 72 2.83 44 1.73 8 0.32 M30 GX-MK30□ 63 2.48 41 1.61 13 0.51 74 2.91 41 1.61 13 0.51 2 m cable length type (mm in) Standard type, Long range type a Other Products a M8 Sensors b Amplifierseparated F M12 plug-in connector type (mm in) DC 2-wire type UV CURING SYSTEMS Amplifier Built-in 2 m cable length type (mm in) Shielded type LASER MARKERS Selection Guide The CAD data can be downloaded from our website. DC 3-wire type LED STATIC CONTROL DEVICES MACHINE VISION SYSTEMS Refer to p.1579~ for general precautions. Others MEASUREMENT SENSORS PLC GX-M SERIES M12 plug-in connector type (mm in) (M8 size: M12 pigtailed type) a b a b M8 GX-M(L)8□-U (-J) 33 1.30 25 0.98 - 24 0.94 M12 GX-M(L)12□-U (-Z) 35 1.38 25 0.98 50 1.97 30 1.18 M18 GX-M(L)18□-U (-Z) 39 1.54 28 1.10 50 1.97 28 1.10 M30 GX-M(L)30□-U (-Z) 43 1.69 32 1.26 55 2.17 32 1.26 824 MEMO
GX-M18B-P 价格&库存

很抱歉,暂时无法提供与“GX-M18B-P”相匹配的价格&库存,您可以联系我们找货

免费人工找货