GXL-15FU-R-C5

GXL-15FU-R-C5

  • 厂商:

    NAIS(松下)

  • 封装:

    Module

  • 描述:

    SENSOR PROX INDUCT 4MM IP67 MOD

  • 详情介绍
  • 数据手册
  • 价格&库存
GXL-15FU-R-C5 数据手册
823 DC 2-wire type Micro-size Inductive Proximity Sensor GXL SERIES FIBER SENSORS Related Information ■■General terms and conditions.............. F-7 ■■Glossary of terms........................ P.1482~ Amplifier Built-in ■■Sensor selection guide.................. P.803~ ■■General precautions.................... P.1485~ LASER SENSORS PHOTOELECTRIC SENSORS Conforming to EMC Directive MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS panasonic.net/id/pidsx/global MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX Flexible cable Different freq. type available type available High performance in micro-size design BASIC PERFORMANCE Versatile mounting Reduced wiring operation Since the sensor is fingertip size, it can be mounted in a tight space. The wiring cost of the DC 2-wire type is 2/3 that of a conventional model. Besides, the possibility of miswiring is reduced. Particularly convenient when many sensors are used. UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated 2-wire type Oil resistant available Wiring of the 3-wire type is cumbersome. Wiring of the 2-wire type is simple and neat. ENVIRONMENTAL RESISTANCE Others Flexible cable type Cost performance The bending durability of its cable is ten times that of the conventional model. The sensor can be mounted on a moving table or a robot arm. Achieve high performance at an affordable price. DC 2-wire type Micro-size Inductive Proximity Sensor GXL SERIES APPLICATIONS 824 FIBER SENSORS Detecting wafer frame Wafer Detecting aluminum pallet Code reading LASER SENSORS PHOTOELECTRIC SENSORS Wafer frame MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS ORDER GUIDE SENSOR OPTIONS GXL-8 type Front sensing Top sensing DC 2-wire Type Appearance (mm in) Sensing range (Note 1) Model No. (Note 2) SIMPLE WIRE-SAVING UNITS Output GXL-8FU 7.4 0.291 8 0.315 20 0.787 Maximum operation distance 2.5 mm 0.098 in (0 to 1.8 mm) (0 to 0.071 in) 8 0.315 8 0.315 23 0.906 Stable sensing range Normally open GXL-8FUI GXL-8FUB GXL-8FUIB GXL-8HU Output operation Normally closed Non-contact DC 2- wire type Normally open GXL-8HUI WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES GXL-8HUB Normally closed GXL-8HUIB Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 2) “ I ” in the model No. indicates a different frequency type. ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS GXL-15 (Standard) type Front sensing Top sensing DC 2-wire Type Appearance (mm in) Sensing range (Note 1) Model No. (Note 2) Output GXL-15FU 8 0.315 15 0.591 32 1.260 Maximum operation distance 5 mm 0.197 in (0 to 4 mm) (0 to 0.157 in) 15 0.591 15 0.591 30 1.181 Stable sensing range Normally open GXL-15FUI GXL-15HU GXL-15HUI GXL-15HUB GXL-15HUIB Selection Guide Amplifier Built-in Amplifierseparated GXL-15FUB GXL-15FUIB Output operation Normally closed Non-contact DC 2- wire type GX-F/H Normally open GXL GL Normally closed Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 2) “ I ” in the model No. indicates a different frequency type. GX-M GX-U/GX-FU/ GX-N GX 825 DC 2-wire type Micro-size Inductive Proximity Sensor ORDER GUIDE FIBER SENSORS GXL-15 (Long sensing range) type ··· For mounting on non-magnetic material (Note 3) Type MICRO PHOTOELECTRIC SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS DC 2-wire AREA SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS Front sensing PHOTOELECTRIC SENSORS Top sensing LASER SENSORS GXL SERIES Appearance (mm in) Sensing range (Note 1) Model No. (Note 2) Output Output operation GXL-15FLU 8 0.315 15 0.591 32 1.260 Maximum operation distance 8 mm 0.315 in (0 to 6.4 mm) (0 to 0.252 in) 15 0.591 15 0.591 30 1.181 Stable sensing range Normally open GXL-15FLUI GXL-15FLUB GXL-15FLUIB GXL-15HLU Normally closed Non-contact DC 2- wire type GXL-15HLUI GXL-15HLUB GXL-15HLUIB Normally open Normally closed Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 2) “ I ” in the model No. indicates a different frequency type. Aluminum sheet 3) To mount the long sensing range GXL-15 type on a magnetic body, such as iron, the enclosed aluminum sheet, or any other aluminum sheet having a minimum size of 30 × 39.5 × t 0.3 mm 1.181 × 1.555 × t 0.012 in (GXL-15HLU type: 30 × 30 × t 0.3 mm 1.181 × 1.181 × t 0.012 in), should be inserted between the sensor and the magnetic body. However, it is not necessary to use the aluminum sheet when mounting on a non-magnetic body, such as, aluminum or an insulator. Flexible cable type and 5 m 16.404 ft cable length type Flexible cable type and 5 m 16.404 ft cable length type (standard: 1 m 3.281 ft) are also available. HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS • Table of Model Nos. Type FA COMPONENTS MACHINE VISION SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX DC 2-wire UV CURING SYSTEMS Top sensing Front sensing Top sensing Front sensing Top sensing Front sensing PLC Standard GXL-8FU GXL-8FUI GXL-8FUB GXL-8FUIB GXL-8HU GXL-8HUI GXL-8HUB GXL-8HUIB GXL-15FU GXL-15FUI GXL-15FUB GXL-15FUIB GXL-15HU GXL-15HUI GXL-15HUB GXL-15HUIB GXL-15FLU GXL-15FLUI GXL-15FLUB GXL-15FLUIB GXL-15HLU GXL-15HLUI GXL-15HLUB GXL-15HLUIB Flexible cable type GXL-8FU-R GXL-8FUI-R GXL-8FUB-R GXL-8FUIB-R GXL-8HU-R GXL-8HUI-R GXL-8HUB-R GXL-8HUIB-R GXL-15FU-R GXL-15FUI-R GXL-15FUB-R GXL-15FUIB-R GXL-15HU-R GXL-15HUI-R GXL-15HUB-R GXL-15HUIB-R GXL-15FLU-R GXL-15FLUI-R GXL-15FLUB-R GXL-15FLUIB-R GXL-15HLU-R GXL-15HLUI-R GXL-15HLUB-R GXL-15HLUIB-R 5 m 16.404 ft cable length type GXL-8FU-C5 GXL-8FUI-C5 GXL-8FUB-C5 GXL-8FUIB-C5 GXL-8HU-C5 GXL-8HUI-C5 GXL-8HUB-C5 GXL-8HUIB-C5 GXL-15FU-C5 GXL-15FUI-C5 GXL-15FUB-C5 GXL-15FUIB-C5 GXL-15HU-C5 GXL-15HUI-C5 GXL-15HUB-C5 GXL-15HUIB-C5 GXL-15FLU-C5 GXL-15FLUI-C5 GXL-15FLUB-C5 GXL-15FLUIB-C5 GXL-15HLU-C5 GXL-15HLUI-C5 GXL-15HLUB-C5 GXL-15HLUIB-C5 Flexible cable of 5 m 16.404 ft cable length type GXL-8FU-R-C5 GXL-8FUI-R-C5 GXL-8FUB-R-C5 GXL-8FUIB-R-C5 GXL-8HU-R-C5 GXL-8HUI-R-C5 GXL-8HUB-R-C5 GXL-8HUIB-R-C5 GXL-15FU-R-C5 GXL-15FUI-R-C5 GXL-15FUB-R-C5 GXL-15FUIB-R-C5 GXL-15HU-R-C5 GXL-15HUI-R-C5 GXL-15HUB-R-C5 GXL-15HUIB-R-C5 GXL-15FLU-R-C5 GXL-15FLUI-R-C5 GXL-15FLUB-R-C5 GXL-15FLUIB-R-C5 GXL-15HLU-R-C5 GXL-15HLUI-R-C5 GXL-15HLUB-R-C5 GXL-15HLUIB-R-C5 DC 2-wire type Micro-size Inductive Proximity Sensor GXL SERIES ORDER GUIDE 826 FIBER SENSORS Accessories • MS-GXL8-4 (Sensor mounting bracket for GXL-8FU, GXL-8HU type) • MS-A15F (Aluminum sheet for GXL-15FLU type) • MS-A15H (Aluminum sheet for GXL-15HLU type) • MS-GXL8-4 • MS-A15F • MS-A15H LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS 1 pc. each of M3 (length: 12 mm 0.472 in) truss head screw, nut, spring washer and plain washer is attached. Not included with the MS-GXL12-1. (Bracket only) Please use only the items included with the sensor. SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS OPTIONS Designation Sensor mounting bracket MEASUREMENT SENSORS Model No. Description MS-GXL15 Mounting bracket for GXL-15 type MS-GXL15-2 Mounting bracket for GXL-15F type Sensor mounting bracket • MS-GXL15 • MS-GXL15-2 STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES MS-GXL15 Screws are not supplied. Screws are not supplied. ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX 827 DC 2-wire type Micro-size Inductive Proximity Sensor SPECIFICATIONS FIBER SENSORS LASER SENSORS DC 2-wire type GXL-15 type PHOTOELECTRIC SENSORS Type MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Max. operation distance (Note 3) Stable sensing range (Note 3) Standard sensing object Hysteresis FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Amplifier Built-in Amplifierseparated GXL GL GX-M GX-U/GX-FU/ GX-N GX Front sensing Top sensing Front sensing Top sensing GXL-8FU GXL-8HU GXL-15FU GXL-15HU GXL-15FLU GXL-15HLU 2.5 mm 0.098 in ±20 % 5 mm 0.197 in ±10 % 8 mm 0.315 in ±10 % 0 to 1.8 mm 0 to 0.071 in 0 to 4 mm 0 to 0.157 in 0 to 6.4 mm 0 to 0.252 in Iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less 12 to 24 V DC ±10 %   Ripple P-P 10 % or less 0.8 mA or less Non-contact DC 2-wire type • Load current: 3 to 100 mA (Note 5) • Residual voltage: 3 V or less (Note 6) Utilization category DC-12 or DC-13 Short-circuit protection Incorporated Max. response frequency Operation indicator 2-color indicator 1 kHz Normally closed type: Red LED (lights up when the output is ON) Normally open type: Lights up in green under stable sensing condition Lights up in red under unstable sensing condition Pollution degree 3 (Industrial environment) Protection Ambient temperature IP67 (IEC), IP67G (Note 7) –25 to +70 °C –13 to +158 °F, Storage: –30 to +80 °C –22 to +176 °F Ambient humidity 45 to 85 % RH, Storage: 35 to 95 % RH EMC EN 60947-5-2 Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each Shock resistance Over ambient temperature range –25 to +70 °C –13 to +158 °F: Within+15 –10 % of sensing range at +20 °C +68 °F Voltage characteristics Within ±2 % for ±10 % fluctuation of the supply voltage Material Cable (Note 8) Weight Accessories 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each Temperature characteristics Cable extension GX-F/H Top sensing Non-contact DC 2-wire type • Load current: 3 to 70 mA (Note 5) • Residual voltage: 3 V or less (Note 6) Output Sensing range variation Selection Guide Front sensing Current consumption (Note 4) Environmental resistance ENERGY CONSUMPTION VISUALIZATION COMPONENTS Long sensing range (For mounting on non-magnetic body) (Note 2) Standard Supply voltage PLC HUMAN MACHINE INTERFACES GXL-8 type 20 % or less of operation distance (with standard sensing object) Repeatability MEASUREMENT SENSORS LASER MARKERS Standard Model No. Item WIRE-SAVING SYSTEMS STATIC ELECTRICITY PREVENTION DEVICES GXL SERIES Enclosure: PBT, Indicator part: Polyalylate 0.15 mm2 2-core oil, heat and cold resistant cable, 1 m 3.281 ft long Enclosure: PET Enclosure: PBT Enclosure: PET Indicator part: Indicator part: Indicator part: Polyalylate Polyalylate Polyalylate 0.2 mm2 2-core oil, heat and cold resistant cable, 1 m 3.281 ft long Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. Net weight: 12 g approx. MS-GXL8-4 (Sensor mounting bracket): 1 set Net weight: 20 g approx. – MS-A15F MS-A15H (Aluminum sheet): 1 pc. (Aluminum sheet): 1 pc. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) To mount the long sensing range type on a magnetic body, such as iron, the enclosed aluminum sheet, or any other aluminum sheet having a minimum size of 30 × 39.5 × t 0.3 mm 1.181 × 1.555 × t 0.012 in (GXL-15HLU type: 30 × 30 × t 0.3 mm 1.181 × 1.181 × t 0.012 in), should be inserted between the sensor and the magnetic body. However, it is not necessary to use the aluminum sheet when mounting on a non-magnetic body, such as, aluminum or an insulator. 3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 4) It is the leakage current when the output is in the OFF state. 5) The maximum load current varies with the ambient temperature. Refer to “I/O CIRCUIT AND WIRING DIAGRAMS (p.828)” for more details. 6) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V. 7) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand. 8) The flexible cable type (model No. with suffix “-R”) has a 0.15 mm2 (GXL-15 type: 0.2 mm2) flexible, oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long. DC 2-wire type Micro-size Inductive Proximity Sensor GXL SERIES I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS LASER SENSORS DC 2-wire type PHOTOELECTRIC SENSORS GXL-8 type I/O circuit diagram Sensor circuit ZD Color code Bleeder resistance Bleeder resistance Brown Load 3 to 70 mA in ON state (Note) 0.8 mA in OFF state + 3 V in ON state – (Blue) 0 V Internal circuit MICRO PHOTOELECTRIC SENSORS Wiring diagram (Brown) Output Tr AREA SENSORS + 12 to 24 V DC ±10 % – Blue LIGHT CURTAINS / SAFETY COMPONENTS Load 12 to 24 V DC PRESSURE / ±10 % FLOW SENSORS Load INDUCTIVE PROXIMITY SENSORS Load PARTICULAR USE SENSORS Users’ circuit SENSOR OPTIONS Symbols … ZD: Surge absorption zener diode Tr : PNP output transistor Max. load current (mA) Note: The maximum load current varies depending on the ambient temperature. 70 35 SIMPLE WIRE-SAVING UNITS Conditions for the load 1) T  he load should not be actuated by the leakage current (0.8 mA) in the OFF state. 2) T  he load should be actuated by (supply voltage – 3 V) in the ON state. 3) T  he current in the ON state should be between 3 to 70 mA DC. In case the current is less than 3 mA, connect a bleeder resistance in parallel to the load so that a current of 3 mA, or more, flows. 3 –25 –13 828 Ambient temperature (°C °F) +55 +131 WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS +70 +158 PLC GXL-15 type I/O circuit diagram Sensor circuit (Brown) Output Tr ZD Color code Bleeder resistance ENERGY CONSUMPTION VISUALIZATION COMPONENTS Bleeder resistance Brown Load 3 to 100 mA in ON state (Note) 0.8 mA in OFF state + 3 V in ON state – (Blue) 0 V Internal circuit HUMAN MACHINE INTERFACES Wiring diagram FA COMPONENTS Load + 12 to 24 V DC ±10 % – Blue 12 to 24 V DC ±10 % Load UV CURING SYSTEMS Load Users’ circuit Symbols … ZD: Surge absorption zener diode Tr : PNP output transistor Selection Guide Note: The maximum load current varies depending on the ambient temperature. Max. load current (mA) MACHINE VISION SYSTEMS 100 50 Conditions for the load 1) T  he load should not be actuated by the leakage current (0.8 mA) in the OFF state. 2) T  he load should be actuated by (supply voltage – 3 V) in the ON state. 3) T  he current in the ON state should be between 3 to 100 mA DC. In case the current is less than 3 mA, connect a bleeder resistance in parallel to the load so that a current of 3 mA, or more, flows. Amplifier Built-in Amplifierseparated GX-F/H GXL GL 3 –25 –13 Ambient temperature (°C °F) +55 +131 +70 +158 GX-M GX-U/GX-FU/ GX-N GX 829 DC 2-wire type Micro-size Inductive Proximity Sensor SENSING CHARACTERISTICS (TYPICAL) FIBER SENSORS GXL-8 type INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 1 0.039 4 0.157 Top sensing 2 0.079 0 10 0.394 GL GX-U/GX-FU/ GX-N GX As the sensing object size becomes smaller than the standard size (iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in), the sensing range shortens as shown in the left figures. Brass 1 0.039 Aluminum 0 20 0.787 5 10 15 0.197 0.394 0.591 Sensing object side length a (mm in) 20 0.787 GXL-15 (Long sensing range) type 8 0.315 5 0 5 10 0.197 0.197 0.394 Left Center Right Operating point ℓ (mm in) 6 0.236 Sensing object a × a mm a × a in L t 1 mm t 0.039 in Front sensing Stainless steel (SUS304) 4 0.157 2 0.079 0 Iron Brass L Top sensing t 1 mm Aluminum t 0.039 in Sensing object a × a mm a × a in 10 20 30 0.394 0.787 1.181 Sensing object side length a (mm in) 40 1.575 As the sensing object size becomes smaller than the standard size (iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in), the sensing range shortens as shown in the left figure. Sensing field • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Mounting GXL-8 type • The tightening torque should be 0.5 N·m or less. • To mount the sensor with a nut, the thru-hole diameter should be ø3.4 mm ø0.134 in. With the attached mounting screw and nut, take care that the thickness of the mounting plate should be 2.3 mm 0.091 in or less. • If a screw other than the attached screw is used, make sure to use a M3 truss head screw. Do not use a flat head screw or a pan head screw. M3 (length 12 mm 0.472 in) truss head screw (Accessory) MS-GXL8-4 (Accessory) M3 × 0.5 mm 0.020 in tapped hole (Depth: 8 mm 0.315 in or more) or ø3.4 mm ø0.134 in thru-hole 11.5 mm 0.453 in If mounting using nut and washers (Accessories) ø2.4 mm ø0.094 in hole (Depth: 3 mm 0.118 in or more) Correlation between sensing object size and sensing range Standard sensing object Standard sensing object Iron sheet 30 × 30 × t 1 mm Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in 1.181 × 1.181 × t 0.039 in 10 ℓ ℓ 0.394 L L Front sensing Top sensing 5 0.197 0 10 0.394 5 0 5 10 0.197 0.197 0.394 Left Center Right Operating point ℓ (mm in) 10 0.394 L Sensing object a × a mm a × a in t 1 mm t 0.039 in Top sensing Iron Stainless steel (SUS304) 5 0.197 Brass L Front sensing 0 t 1 mm Aluminum t 0.039 in Sensing object a × a mm a × a in 10 20 30 0.394 0.787 1.181 Sensing object side length a (mm in) 40 1.575 As the sensing object size becomes smaller than the standard size (iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in), the sensing range shortens as shown in the left figure. PRECAUTIONS FOR PROPER USE Amplifierseparated GX-M 5 10 15 0.197 0.394 0.591 Sensing object side length a (mm in) Correlation between sensing object size and sensing range 8 Standard sensing object 0.315 Iron sheet 20 × 20 × t 1 mm Standard sensing object Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in 0.787 × 0.787 × t 0.039 in ℓ ℓ 6 L L 0.236 Front sensing Amplifier Built-in GXL 0 5 0 5 10 0.197 0.197 0.394 Left Center Right Operating point ℓ (mm in) Selection Guide GX-F/H Aluminum 1 0.039 Sensing field Setting distance L (mm in) STATIC ELECTRICITY PREVENTION DEVICES 4 Sensing object Sensing object 0.157 a × a mm a × a in a × a mm a × a in t 1 mm t 1 mm L L t 0.039 in t 0.039 in 3 Top sensing 0.118 Iron Front sensing Stainless steel (SUS304) 2 0.079 GXL-15 (Standard) type WIRE-SAVING SYSTEMS MEASUREMENT SENSORS 2 0.079 0 10 0.394 PARTICULAR USE SENSORS 4 Sensing object Sensing object 0.157 a a mm a a in a × a mm a × a in × × t 1 mm t 1 mm L L t 0.039 in t 0.039 in 3 Top sensing 0.118 Iron Front sensing Stainless steel (SUS304) 2 0.079 Brass Sensing range L (mm in) PRESSURE / FLOW SENSORS Standard sensing object Iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in ℓ L L Top sensing Correlation between sensing object size and sensing range (NPN output type) Setting distance L (mm in) LIGHT CURTAINS / SAFETY COMPONENTS Setting distance L (mm in) AREA SENSORS 4 Standard sensing object 0.157 Iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in ℓ 3 Front sensing 0.118 Correlation between sensing object size and sensing range (DC 2-wire type) Sensing range L (mm in) Sensing field (common) MICRO PHOTOELECTRIC SENSORS Sensing range L (mm in) PHOTOELECTRIC SENSORS Sensing range L (mm in) LASER SENSORS GXL SERIES Refer to p.1485~ for general precautions. GXL-15 type M3 pan head screw • The tightening torque should be 1 N·m or or truss head screw less. not use a ( Do flat head screw ) • To mount the sensor with the optional sensor mounting bracket MS-GXL15, the thru-hole M3 × 0.5 mm 0.020 in tapped hole or ø3.4 mm ø0.134 in thru-hole diameter should be ø3.4 mm ø0.134 in. 9 mm • Screw, nut or washers are not supplied. 0.354 in Please arrange them separately. If mounting using nut • To mount the long sensing range type on a and washers. magnetic body, such as iron, the enclosed When mounting using MS-GXL15 (Optional) aluminum sheet, or any other aluminum sheet having a minimum size of 30 × 39.5 × t 0.3 mm 1.181 × 1.555 × t 0.012 in Aluminum sheet (GXL-15HLU type: 30 × 30 × t 0.3 mm 1.181 × 1.181 × t 0.012 in), should be inserted between the sensor and the magnetic body. However, it is not necessary to use the aluminum sheet when mounting on a nonSensor mounting magnetic body, such as, aluminum or an bracket’s mounting insulator. holes • When mounting the inductive proximity sensor with the optional sensor mounting bracket MS-GXL15-2, if the bracket is Sensor’s mounting mounted close to the sensing part, the holes bracket itself gets sensed and the operation MS-GXL15-2 sensor becomes unstable. Make sure to mount such (Optional mounting bracket) that the mounting holes of the sensor and those of the mounting bracket are in one horizontal straight line. GXL-15F DC 2-wire type Micro-size Inductive Proximity Sensor PRECAUTIONS FOR PROPER USE Refer to p.1485~ for general precautions. Influence of surrounding metal Front sensing type Metal C • The sensing range is specified for the standard sensing object. With a non-ferrous metal, the sensing range is obtained by multiplying with the correction coefficient specified below. Further, the sensing range also changes if the sensing object is smaller than the standard sensing object or if the sensing object is plated. Correction coefficient C Model No. Metal A GXL-8 type Metal GXL-8F type GXL-15FU type GXL-15FLU type A 7 mm 0.276 in 8 mm 0.315 in 8 mm 0.315 in (Note) B 8 mm 0.315 in 20 mm 0.787 in 30 mm 1.181 in C 3 mm 0.118 in 7 mm 0.276 in 10 mm 0.394 in Note: The GXL-15FLU type should be mounted on an insulator or a non-magnetic body. To mount it on a magnetic body, such as iron, use the enclosed aluminum sheet. Metal Metal D Iron Stainless steel (SUS304) Brass 1 1 1 0.82 approx. 0.74 approx. 0.75 approx. 0.59 approx. 0.53 approx. 0.53 approx. Aluminum 0.57 approx. 0.52 approx. 0.51 approx. G F GXL-8H type GXL-15HU type GXL-15HLU type D 4 mm 0.157 in 6 mm 0.236 in 12 mm 0.472 in E 10 mm 0.394 in 20 mm 0.787 in 30 mm 1.181 in F 3 mm 0.118 in 0 mm 0 in 10 mm 0.394 in (Note) G 3 mm 0.118 in 3 mm 0.118 in 10 mm 0.394 in Note: When GXL-15HLU type is mounted on an insulator or a non-magnetic body, or seated on the enclosed aluminum sheet, the distance “F” can be zero. • When two or more sensors are installed in parallel or face to face, keep the minimum separation distance specified below to avoid mutual interference. Between “I” type and non “I” type J Front sensing 0 mm 15 mm (Note 2) 0.591 in Between two “I” types 18 mm 30 mm or two non “I” types 0.709 in 1.181 in Between “I” type GXL-15FU and non “I” type 0 mm 25 mm (Note 2) 0.984 in GXL-15HU Between two “I” types 30 mm 60 mm type or two non “I” types 1.181 in 2.362 in Between “I” type 0 mm SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS J H H 25 mm GXL-15FLU and non “I” type (Note 2) 0.984 in GXL-15HLU Between two “I” types 75 mm 90 mm type or two non “I” types 2.953 in 3.543 in Notes: 1) “I” in the model No. specifies the different frequency type. 2) Close mounting is possible for up to two sensors. When mounting three sensors or more at an equal spacing, align the model with “I” and the model without “I” alternately. The minimum value of dimension “H” should be as given below. GXL-8 type: 5 mm 0.1975 in, GXL-15FU/15HU type: 7.5 mm 0.295 in, GXL-15FLU/15HLU type: 30 mm 1.181 in Top sensing DC power supply + – STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS DC power supply FA COMPONENTS Blue lead wire Series connection (AND circuit) Parallel connection (OR circuit) When all sensors are in the ON state, the load voltage Load VRL is given by: VRL = Vcc – n × 3 (V) VRL Vcc: supply voltage + Vcc ( 24 V DC max.) – n: number of sensors Make sure that the load can work properly at this voltage. Load Icc (IL) + – Note: The output is generated normally even if the indicator does not light up properly. When all sensors are in the OFF state, the load leakage current Icc is given by: Icc = n × 0.8 (mA) (n : number of sensors) Make sure that the load can work properly. Vcc Note : The load current in the ON state is given by : Vcc – 3 V IL = Load resistance (mA) GXL-8 type : 3 mA × n ≤ lL ≤ 70 mA n: number of sensors turned ON GXL-15 type : 3 mA × n ≤ lL ≤ 100 mA n: number of sensors turned ON ( ) ( ) • The residual voltage of the sensor is 3 V. Before connecting a relay at the load, take care of its actuation voltage. (Some 12 V relays may not be usable.) H MEASUREMENT SENSORS • For series connection (AND circuit) or parallel connection (OR circuit) of sensors, take care of the following. J Relay actuation voltage: VR ≤ 12 – 3V ≤ 9V ) ( Relay GXL-8 type SENSOR OPTIONS Brown lead wire Brown lead wire Mutual interference prevention H PARTICULAR USE SENSORS • The sensor must be connected to a power supply via a load. If the sensor is connected to a power supply without a load, the short-circuit protection makes the sensor inoperable. (The output stays in the OFF state and the indicator does not light up.) In this case, rectify by connecting the power supply via a load. Now, the sensor becomes operable. Further, take care that if the power supply is connected with reverse polarity without a load, the sensor will get damaged. + – VR Relay actuation voltage Brown lead wire ( + 12 V DC – power supply VS = 3 V Residual voltage when the sensor is in the ON state Blue lead wire ) AREA SENSORS INDUCTIVE PROXIMITY SENSORS Others Blue lead wire MICRO PHOTOELECTRIC SENSORS PRESSURE / FLOW SENSORS Wiring Metal G E GXL-15FU type PHOTOELECTRIC SENSORS LIGHT CURTAINS / SAFETY COMPONENTS GXL-15HU GXL-15FLU GXL-15HLU type • Do not use during the initial transient time (50 ms) after the power supply is switched on. Top sensing type FIBER SENSORS LASER SENSORS Sensing range • When there is a metal near the sensor, keep the minimum separation distance specified below. B 830 GXL SERIES MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX 831 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS PRECAUTIONS FOR PROPER USE PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS • Following work must be done in case of using this product as a CE Marking (European standard EMC Directive)conforming product. Ensure that the shield is connected to 0 V. 0V Shield (piping, etc.) Power supply / OUT Load Sensor Note: The shield (piping, etc.) must be insulated. DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. GXL-8FU type Sensor WIRE-SAVING SYSTEMS LASER MARKERS ( 8 0.315 7.4 0.291 (1) (0.039) ENERGY CONSUMPTION VISUALIZATION COMPONENTS 21 20 11.5 0.827 0.787 0.453 4 0.157 Sensing direction 3.3 0.130 3 0.118 ø3 ø0.118 mounting hole ø2.9 ø0.114 cable, 1 m 3.281 ft long 5 0.197 5.5 0.217 4 0.157 8 0.315 3 0.118 8 0.315 5.3 0.209 5.5 0.217 9.2 0.362 4.6 0.181 7.4 0.291 2.6 0.102 ø3 ø0.118 mounting hole ø2.9 ø0.114 cable, 1 m 3.281 ft long 5 10.5 0.197 0.413 (4.5) 18.5 (0.177) 0.728 6.8 1.4 0.055 0.268 2-color indicator (Red,green) (Only red LED for normally closed type) 4 0.157 4 0.157 7.4 0.291 7.3 0.287 4.5 0.177 4 0.157 5 0.197 7.4 0.291 GXL-8FU FA COMPONENTS MACHINE VISION SYSTEMS 5.2 0.205 ) Sensor 7.4 Sensing 0.291 direction PLC HUMAN MACHINE INTERFACES GXL-8HU type 2-color indicator (Red, green) Only red LED for normally closed type MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES Refer to p.1485~ for general precautions. Use conditions to comply with CE Marking AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS GXL SERIES GXL-8HU FIBER SENSORS DC 2-wire type Micro-size Inductive Proximity Sensor 5.3 0.209 2.6 0.102 2 0.079 3 0.118 23 0.906 UV CURING SYSTEMS Sensor GXL-15H type Sensor 8 0.315 5 0.197 Selection Guide Amplifier Built-in 15 0.591 14.4 0.567 Amplifierseparated GX-F/H GXL GL 7.5 0.295 32 35 1.260 20.5 0.807 1.378 2-color indicator (Note) (Red, green) Sensing direction 15 0.591 GXL-15F GX-U/GX-FU/ GX-N 4 3 0.157 0.118 9 0.354 14.4 0.567 13 0.512 2-ø3.2 ø0.126 mounting holes ø3 ø0.118 cable, 1 m 3.281 ft long 7 0.276 14.4 0.567 5.7 0.224 2.8 0.110 Note: Normally closed type have an operation indicator (red) instead of the 2-color indicator. ø3 ø0.118 cable, 1 m 3.281 ft long 9 ø5.4 ø0.213 0.354 (4) 26 (0.157) 1.024 21 0.827 12.5 0.492 2-color indicator (Note) 12 (Red, green) 0.472 14.4 0.567 GX-M GX Sensing direction 2.8 0.110 2-ø3.2 ø0.126 mounting holes 11 0.433 GXL-15H GXL-15F type 8.5 0.335 6.7 0.264 16 16.5 0.630 0.650 7.9 0.311 7.7 0.303 30 1.181 8.9 0.350 3 0.118 Note: N  ormally closed type have an operation indicator (red) instead of the 2-color indicator. DC 2-wire type Micro-size Inductive Proximity Sensor DIMENSIONS (Unit: mm in) MS-GXL15 Sensor mounting bracket for GXL-15 type (Optional) (16.2) 15.8 (0.638) 0.622 Center of ø2.4 ø0.094 hole, 2 sensing 3 0.118 or more deep 0.079 2 0.079 0.3 0.012 (11.5) 3.3 (0.453) 0.130 t 0.4 t 0.016 11.5 0.453 14 0.551 9 0.354 M3 × 0.5 0.020 tapped hole, 8 0.315 or more deep 4.5 0.177 ø3.1 ø0.122 hole AREA SENSORS 2.5 0.098 LIGHT CURTAINS / SAFETY COMPONENTS 7 0.276 PRESSURE / FLOW SENSORS 2-M3 × 0.5 0.020 tapped hole INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Material: Stainless steel (SUS304) SENSOR OPTIONS 1 pc. each of M3 (length 12 mm 0.472 in) truss head screw, nut, spring washer and plain washer is attached. MS-A15F  MS-A15H Aluminum sheet (Accessory for GXL-15FLU / GXL-15HLU type) 3.2 0.126 30 1.181 24 0.945 LASER MARKERS 2-ø3.2 ø0.126 1.2 0.047 2-3.2 × 5.1 0.126 × 0.201 oblong holes 39.5 1.555(MS-A15H: 30 1.181) Material: B  racket ... Stainless steel (SUS304) Fixed rubber ... FKM (Fluorine rubber) PLC HUMAN MACHINE INTERFACES 6.6 0.260 t 0.5 t 0.020 WIRE-SAVING SYSTEMS STATIC ELECTRICITY PREVENTION DEVICES 8 0.315 16.5 0.650 SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS 30 1.181 4 0.157 LASER SENSORS MICRO PHOTOELECTRIC SENSORS Material: Cold rolled carbon steel (SPCC) MS-GXL15-2 Sensor mounting bracket for GXL-15F type (Optional) FIBER SENSORS PHOTOELECTRIC SENSORS t2 t 0.079 Mounting hole dimensions 2.3 0.091 832 The CAD data in the dimensions can be downloaded from our website. MS-GXL8-4 Sensor mounting bracket for GXL-8FU / GXL-8HU type (Accessory) (9.0) (0.354) GXL SERIES ENERGY CONSUMPTION VISUALIZATION COMPONENTS 4 0.157 Fixed rubber 9 0.354 1.9 0.075 21 0.827 t = 0.3 0.012 1.9 0.075 FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Amplifierseparated GX-F/H GXL GL GX-M GX-U/GX-FU/ GX-N GX
GXL-15FU-R-C5
物料型号: - 型号包括GXL-8FU、GXL-8FUI、GXL-8FUB、GXL-8HU、GXL-15FU、GXL-15FUI、GXL-15FUB、GXL-15HU等。

器件简介: - 这是一系列直流2线式微型电感式接近传感器,具有内置放大器,设计用于紧凑空间的安装,减少了布线工作,并减少了误接线的可能性。

引脚分配: - 文档中没有明确提供引脚分配图,但提到了2线式设计,意味着传感器有两个引脚用于电源和信号输出。

参数特性: - 工作距离:GXL-8型最大2.5mm,GXL-15型最大5mm或8mm,具体取决于型号。 - 稳定感应范围:即使在环境温度变化或电源电压波动下,也能稳定检测标准感应对象。 - 输出类型:非接触式直流2线式,具有常开和常闭选项。 - 工作电压:12到24V直流,纹波P-P不超过10%。 - 电流消耗:不超过0.8mA。

功能详解: - 传感器可用于检测晶圆框架、铝托盘、条形码阅读等应用。 - 提供了不同感应范围和不同频率类型的传感器,以适应不同的应用需求。

应用信息: - 传感器适用于需要小尺寸和高性能的场合,如自动化设备、机器人臂等。

封装信息: - 提供了不同长度的电缆选项,包括抗弯曲电缆和5米长的电缆。 - 还提供了安装支架等配件,以方便安装和使用。