1c, 2c, 4c
To Be Discontinued
Last time buy: September 30, 2018
Standard type
Amber sealed type
Relay for control panel of
1A to 10A (1c/2c/3c/4c)
HC RELAYS
FEATURES
TYPICAL APPLICATIONS
1. Standard type and Amber sealed
type
2. Rich lineup includes relays with
operating indication, with diode
3. Full range of types
Plug-in type, PC board type and TM
type
4. Sockets and terminal sockets are
available.
1. Factory automation equipment and
automotive devices
2. Control panels, power supply
equipment, molding equipment,
machine tools, welding equipment,
agricultural equipment, etc.
3. Office equipment, automatic
vending machines,
telecommunications equipment,
disaster prevention equipment,
copiers, measuring devices, medical
equipment, amusement devices, etc.
4. All types of household appliance
With diode type
RoHS compliant
Protective construction: Dust cover type/
Sealed type
ORDERING INFORMATION
Standard type
Amber sealed type
HC
HC
Contact arrangement
1: 1 Form C
2: 2 Form C
3: 3 Form C
4: 4 Form C
4D: Bifurcated contact (twin)
Contact arrangement
1: 1 Form C
2: 2 Form C
4: 4 Form C
E: Amber sealed type
ED: Amber sealed type bifurcated contact
(twin) (Only 4 Form C)
Terminal arrangement
H:
Plug-in type
HL: Plug-in with LED indication
HP: PC board type
HPL: PC board with LED indication
HTM: TM type
Terminal arrangement
H:
Plug-in type
L:
Plug-in with LED indication
HP: PC board type
PL: PC board with LED indication
HTM: TM type
Nominal coil voltage
AC: 6, 12, 24, 48, 100 (100/110), 120 (110/120),
200 (200/220), 240 (220/240) V
DC: 6, 12, 24, 48, 100 (100/110) V
Nominal coil voltage
AC: 6, 12, 24, 48, 100 (100/110), 120 (110/120),
200 (200/220), 240 (220/240) V
DC: 6, 12, 24, 48, 100 (100/110) V
Contact material
Contact
material
Contact
arrangement
1 Form C
2 Form C
3 Form C
4 Form C
4-pole bifurcated (twin)
AgSnO2 type
Contact material
AgNi type
Contact
material
Contact
arrangement
1 Form C
2 Form C
4 Form C
4-pole bifurcated (twin)
F
F
F
Nil
Nil
–1–
AgSnO2 type
AgNi type
F
F
Nil
Nil
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
With diode type (For DC)
HC
Contact arrangement
1: 1 Form C
2: 2 Form C
3: 3 Form C
4: 4 Form C
4D: Bifurcated contact (twin)
Terminal arrangement
Nil: Plug-in type
L: Plug-in with LED indication
Nominal coil voltage
DC: 6, 12, 24, 48, 100 (100/110) V
Surge suppression
D: With diode
Contact material
Contact
material
Contact
arrangement
1 Form C
2 Form C
3 Form C
4 Form C
4-pole bifurcated (twin)
AgSnO2 type
AgNi type
F
F
F
Nil
Nil
LINEUP
Type
Contact arrangement
Remarks
Plug-in terminal type
Without LED
With LED
HC relay
Standard type
Single side stable
Bifurcated (Twin)
HC relay
Amber sealed
type
Single side stable
DC type with
surge absorbing
diode
Single side stable
Bifurcated (Twin)
Bifurcated (Twin)
PC board terminal type
Without LED
With LED
Top mounting type
(TM type)
1 Form C
2 Form C
3 Form C
4 Form C
4 Form C
1 Form C
2 Form C
4 Form C
4 Form C
1 Form C
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
—
A
A
A
A
A
A
A
A
A
—
A
A
A
A
A
A
A
A
A
—
2 Form C
3 Form C
4 Form C
4 Form C
A
A
A
A
A
A
A
A
—
—
—
—
—
—
—
—
—
—
—
—
Amber sealed type
also available
A: Available
Notes: 1. HC relays with ground terminals also available.
2. HC relays with 0.9 mm wide PC board terminals also available.
HC RELAY CONTACT ARRANGEMENT
Type
Part number
Features
Single side stable contact
HC�
Suitable for high-capacity load switching
Standard type HC relays have high single-contact capacity;
1 Form C: 10 A
2 Form C and 3 Form C: 7 A
4 Form C: 5 A
4-pole bifurcated (twin) contact
HC4D
Bifurcated (twin) contact ensures high contact reliability
Suitable for low level loads
Minimum switching capability: 100 μA 100m V DC (reference value)
–2–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
LED INDICATION TYPE
Type
Part number
Features
With LED indication type
HC�-HL
LED lights up when relay is operating
Inspection and detection of trouble is easy.
LEDs are green for DC types and red for
AC types.
All types are available with LED indication.
1
2
3
4
5
6
7
8
9
10
11
12
13 –
+14
LED
• LED colors indicate the type of relay:
red for AC type and green for DC type.
Protection diode
(Bottom view)
HC RELAY SERIES PRODUCT TYPES
Type
Part number
Features
Amber sealed type HC relay
HC�E
HC relay with diode type (for DC)
HC�-�-�V-D
Has built-in diode to absorb surge when the coil goes to the off state (for
Relay is completely sealed with resin.
DC type).
Provides high reliability in adverse surroundings.
Suitable for protecting relay driver circuits and for noise suppression
Suitable for use in dusty conditions or where organic gases are present Diode characteristics: Reverse breakdown voltage 1,000 V
Forward current 1 A
4-pole bifurcated (twin) type and Relay with LED indication are available.
TYPES
1. Standard type
1) Plug-in type
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-H-AC6V-F
HC1-H-AC12V-F
HC1-H-AC24V-F
HC1-H-AC48V-F
HC1-H-AC100V-F
HC1-H-AC120V-F
HC1-H-AC200V-F
HC1-H-AC240V-F
HC1-H-DC6V-F
HC1-H-DC12V-F
HC1-H-DC24V-F
HC1-H-DC48V-F
HC1-H-DC100V-F
2 Form C
Part No.
HC2-H-AC6V-F
HC2-H-AC12V-F
HC2-H-AC24V-F
HC2-H-AC48V-F
HC2-H-AC100V-F
HC2-H-AC120V-F
HC2-H-AC200V-F
HC2-H-AC240V-F
HC2-H-DC6V-F
HC2-H-DC12V-F
HC2-H-DC24V-F
HC2-H-DC48V-F
HC2-H-DC100V-F
3 Form C
Part No.
HC3-H-AC6V-F
HC3-H-AC12V-F
HC3-H-AC24V-F
HC3-H-AC48V-F
HC3-H-AC100V-F
HC3-H-AC120V-F
HC3-H-AC200V-F
HC3-H-AC240V-F
HC3-H-DC6V-F
HC3-H-DC12V-F
HC3-H-DC24V-F
HC3-H-DC48V-F
HC3-H-DC100V-F
4 Form C
Part No.
HC4-H-AC6V
HC4-H-AC12V
HC4-H-AC24V
HC4-H-AC48V
HC4-H-AC100V
HC4-H-AC120V
HC4-H-AC200V
HC4-H-AC240V
HC4-H-DC6V
HC4-H-DC12V
HC4-H-DC24V
HC4-H-DC48V
HC4-H-DC100V
4 Form C (twin)
Part No.
HC4D-H-AC6V
HC4D-H-AC12V
HC4D-H-AC24V
HC4D-H-AC48V
HC4D-H-AC100V
HC4D-H-AC120V
HC4D-H-AC200V
HC4D-H-AC240V
HC4D-H-DC6V
HC4D-H-DC12V
HC4D-H-DC24V
HC4D-H-DC48V
HC4D-H-DC100V
2 Form C
Part No.
HC2-HL-AC6V-F
HC2-HL-AC12V-F
HC2-HL-AC24V-F
HC2-HL-AC100V-F
HC2-HL-AC120V-F
HC2-HL-AC200V-F
HC2-HL-AC240V-F
HC2-HL-DC6V-F
HC2-HL-DC12V-F
HC2-HL-DC24V-F
HC2-HL-DC48V-F
HC2-HL-DC100V-F
3 Form C
Part No.
HC3-HL-AC6V-F
HC3-HL-AC12V-F
HC3-HL-AC24V-F
HC3-HL-AC100V-F
HC3-HL-AC120V-F
HC3-HL-AC200V-F
HC3-HL-AC240V-F
HC3-HL-DC6V-F
HC3-HL-DC12V-F
HC3-HL-DC24V-F
HC3-HL-DC48V-F
HC3-HL-DC100V-F
4 Form C
Part No.
HC4-HL-AC6V
HC4-HL-AC12V
HC4-HL-AC24V
HC4-HL-AC100V
HC4-HL-AC120V
HC4-HL-AC200V
HC4-HL-AC240V
HC4-HL-DC6V
HC4-HL-DC12V
HC4-HL-DC24V
HC4-HL-DC48V
HC4-HL-DC100V
4 Form C (twin)
Part No.
HC4D-HL-AC6V
HC4D-HL-AC12V
HC4D-HL-AC24V
HC4D-HL-AC100V
HC4D-HL-AC120V
HC4D-HL-AC200V
HC4D-HL-AC240V
HC4D-HL-DC6V
HC4D-HL-DC12V
HC4D-HL-DC24V
HC4D-HL-DC48V
HC4D-HL-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2) Plug-in type (with LED indication)
Nominal coil voltage
6V AC
12V AC
24V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-HL-AC6V-F
HC1-HL-AC12V-F
HC1-HL-AC24V-F
HC1-HL-AC100V-F
HC1-HL-AC120V-F
HC1-HL-AC200V-F
HC1-HL-AC240V-F
HC1-HL-DC6V-F
HC1-HL-DC12V-F
HC1-HL-DC24V-F
HC1-HL-DC48V-F
HC1-HL-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
–3–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
3) PC board type
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-HP-AC6V-F
HC1-HP-AC12V-F
HC1-HP-AC24V-F
HC1-HP-AC48V-F
HC1-HP-AC100V-F
HC1-HP-AC120V-F
HC1-HP-AC200V-F
HC1-HP-AC240V-F
HC1-HP-DC6V-F
HC1-HP-DC12V-F
HC1-HP-DC24V-F
HC1-HP-DC48V-F
HC1-HP-DC100V-F
2 Form C
Part No.
HC2-HP-AC6V-F
HC2-HP-AC12V-F
HC2-HP-AC24V-F
HC2-HP-AC48V-F
HC2-HP-AC100V-F
HC2-HP-AC120V-F
HC2-HP-AC200V-F
HC2-HP-AC240V-F
HC2-HP-DC6V-F
HC2-HP-DC12V-F
HC2-HP-DC24V-F
HC2-HP-DC48V-F
HC2-HP-DC100V-F
3 Form C
Part No.
HC3-HP-AC6V-F
HC3-HP-AC12V-F
HC3-HP-AC24V-F
HC3-HP-AC48V-F
HC3-HP-AC100V-F
HC3-HP-AC120V-F
HC3-HP-AC200V-F
HC3-HP-AC240V-F
HC3-HP-DC6V-F
HC3-HP-DC12V-F
HC3-HP-DC24V-F
HC3-HP-DC48V-F
HC3-HP-DC100V-F
4 Form C
Part No.
HC4-HP-AC6V
HC4-HP-AC12V
HC4-HP-AC24V
HC4-HP-AC48V
HC4-HP-AC100V
HC4-HP-AC120V
HC4-HP-AC200V
HC4-HP-AC240V
HC4-HP-DC6V
HC4-HP-DC12V
HC4-HP-DC24V
HC4-HP-DC48V
HC4-HP-DC100V
4 Form C (twin)
Part No.
HC4D-HP-AC6V
HC4D-HP-AC12V
HC4D-HP-AC24V
HC4D-HP-AC48V
HC4D-HP-AC100V
HC4D-HP-AC120V
HC4D-HP-AC200V
HC4D-HP-AC240V
HC4D-HP-DC6V
HC4D-HP-DC12V
HC4D-HP-DC24V
HC4D-HP-DC48V
HC4D-HP-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” before “-F” in the part number when ordering the PC board type 0.9 mm width terminal (ex) HC1-HP-AC6V-31-F.
4) PC board type (with LED indication)
Nominal coil voltage
6V AC
12V AC
24V AC
100/110V AC
110/120V AC
200/220V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-HPL-AC6V-F
HC1-HPL-AC12V-F
HC1-HPL-AC24V-F
HC1-HPL-AC100V-F
HC1-HPL-AC120V-F
HC1-HPL-AC200V-F
HC1-HPL-DC6V-F
HC1-HPL-DC12V-F
HC1-HPL-DC24V-F
HC1-HPL-DC48V-F
HC1-HPL-DC100V-F
2 Form C
Part No.
HC2-HPL-AC6V-F
HC2-HPL-AC12V-F
HC2-HPL-AC24V-F
HC2-HPL-AC100V-F
HC2-HPL-AC120V-F
HC2-HPL-AC200V-F
HC2-HPL-DC6V-F
HC2-HPL-DC12V-F
HC2-HPL-DC24V-F
HC2-HPL-DC48V-F
HC2-HPL-DC100V-F
3 Form C
Part No.
HC3-HPL-AC6V-F
HC3-HPL-AC12V-F
HC3-HPL-AC24V-F
HC3-HPL-AC100V-F
HC3-HPL-AC120V-F
HC3-HPL-AC200V-F
HC3-HPL-DC6V-F
HC3-HPL-DC12V-F
HC3-HPL-DC24V-F
HC3-HPL-DC48V-F
HC3-HPL-DC100V-F
4 Form C
Part No.
HC4-HPL-AC6V
HC4-HPL-AC12V
HC4-HPL-AC24V
HC4-HPL-AC100V
HC4-HPL-AC120V
HC4-HPL-AC200V
HC4-HPL-DC6V
HC4-HPL-DC12V
HC4-HPL-DC24V
HC4-HPL-DC48V
HC4-HPL-DC100V
4 Form C (twin)
Part No.
HC4D-HPL-AC6V
HC4D-HPL-AC12V
HC4D-HPL-AC24V
HC4D-HPL-AC100V
HC4D-HPL-AC120V
HC4D-HPL-AC200V
HC4D-HPL-DC6V
HC4D-HPL-DC12V
HC4D-HPL-DC24V
HC4D-HPL-DC48V
HC4D-HPL-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” before “-F” in the part number when ordering the PC board type 0.9 mm width terminal (ex) HC1-HPL-AC6V-31-F.
5) TM type
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-HTM-AC6V-F
HC1-HTM-AC12V-F
HC1-HTM-AC24V-F
HC1-HTM-AC48V-F
HC1-HTM-AC100V-F
HC1-HTM-AC120V-F
HC1-HTM-AC200V-F
HC1-HTM-DC6V-F
HC1-HTM-DC12V-F
HC1-HTM-DC24V-F
HC1-HTM-DC48V-F
HC1-HTM-DC100V-F
2 Form C
Part No.
HC2-HTM-AC6V-F
HC2-HTM-AC12V-F
HC2-HTM-AC24V-F
HC2-HTM-AC48V-F
HC2-HTM-AC100V-F
HC2-HTM-AC120V-F
HC2-HTM-AC200V-F
HC2-HTM-DC6V-F
HC2-HTM-DC12V-F
HC2-HTM-DC24V-F
HC2-HTM-DC48V-F
HC2-HTM-DC100V-F
3 Form C
Part No.
HC3-HTM-AC6V-F
HC3-HTM-AC12V-F
HC3-HTM-AC24V-F
HC3-HTM-AC48V-F
HC3-HTM-AC100V-F
HC3-HTM-AC120V-F
HC3-HTM-AC200V-F
HC3-HTM-DC6V-F
HC3-HTM-DC12V-F
HC3-HTM-DC24V-F
HC3-HTM-DC48V-F
HC3-HTM-DC100V-F
4 Form C
Part No.
HC4-HTM-AC6V
HC4-HTM-AC12V
HC4-HTM-AC24V
HC4-HTM-AC48V
HC4-HTM-AC100V
HC4-HTM-AC120V
HC4-HTM-AC200V
HC4-HTM-DC6V
HC4-HTM-DC12V
HC4-HTM-DC24V
HC4-HTM-DC48V
HC4-HTM-DC100V
4 Form C (twin)
Part No.
HC4D-HTM-AC6V
HC4D-HTM-AC12V
HC4D-HTM-AC24V
HC4D-HTM-AC48V
HC4D-HTM-AC100V
HC4D-HTM-AC120V
HC4D-HTM-AC200V
HC4D-HTM-DC6V
HC4D-HTM-DC12V
HC4D-HTM-DC24V
HC4D-HTM-DC48V
HC4D-HTM-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
–4–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
2. Amber sealed type
1) Plug-in type
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1E-H-AC6V-F
HC1E-H-AC12V-F
HC1E-H-AC24V-F
HC1E-H-AC48V-F
HC1E-H-AC100V-F
HC1E-H-AC120V-F
HC1E-H-AC200V-F
HC1E-H-AC240V-F
HC1E-H-DC6V-F
HC1E-H-DC12V-F
HC1E-H-DC24V-F
HC1E-H-DC48V-F
HC1E-H-DC100V-F
2 Form C
Part No.
HC2E-H-AC6V-F
HC2E-H-AC12V-F
HC2E-H-AC24V-F
HC2E-H-AC48V-F
HC2E-H-AC100V-F
HC2E-H-AC120V-F
HC2E-H-AC200V-F
HC2E-H-AC240V-F
HC2E-H-DC6V-F
HC2E-H-DC12V-F
HC2E-H-DC24V-F
HC2E-H-DC48V-F
HC2E-H-DC100V-F
4 Form C
Part No.
HC4E-H-AC6V
HC4E-H-AC12V
HC4E-H-AC24V
HC4E-H-AC48V
HC4E-H-AC100V
HC4E-H-AC120V
HC4E-H-AC200V
HC4E-H-AC240V
HC4E-H-DC6V
HC4E-H-DC12V
HC4E-H-DC24V
HC4E-H-DC48V
HC4E-H-DC100V
4 Form C (twin)
Part No.
HC4ED-H-AC6V
HC4ED-H-AC12V
HC4ED-H-AC24V
HC4ED-H-AC48V
HC4ED-H-AC100V
HC4ED-H-AC120V
HC4ED-H-AC200V
HC4ED-H-AC240V
HC4ED-H-DC6V
HC4ED-H-DC12V
HC4ED-H-DC24V
HC4ED-H-DC48V
HC4ED-H-DC100V
2 Form C
Part No.
HC2E-L-AC6V-F
HC2E-L-AC12V-F
HC2E-L-AC24V-F
HC2E-L-AC48V-F
HC2E-L-AC100V-F
HC2E-L-AC120V-F
HC2E-L-AC200V-F
HC2E-L-AC240V-F
HC2E-L-DC6V-F
HC2E-L-DC12V-F
HC2E-L-DC24V-F
HC2E-L-DC48V-F
HC2E-L-DC100V-F
4 Form C
Part No.
HC4E-L-AC6V
HC4E-L-AC12V
HC4E-L-AC24V
HC4E-L-AC48V
HC4E-L-AC100V
HC4E-L-AC120V
HC4E-L-AC200V
HC4E-L-AC240V
HC4E-L-DC6V
HC4E-L-DC12V
HC4E-L-DC24V
HC4E-L-DC48V
HC4E-L-DC100V
4 Form C (twin)
Part No.
HC4ED-L-AC6V
HC4ED-L-AC12V
HC4ED-L-AC24V
HC4ED-L-AC48V
HC4ED-L-AC100V
HC4ED-L-AC120V
HC4ED-L-AC200V
HC4ED-L-AC240V
HC4ED-L-DC6V
HC4ED-L-DC12V
HC4ED-L-DC24V
HC4ED-L-DC48V
HC4ED-L-DC100V
2 Form C
Part No.
HC2E-HP-AC6V-F
HC2E-HP-AC12V-F
HC2E-HP-AC24V-F
HC2E-HP-AC48V-F
HC2E-HP-AC100V-F
HC2E-HP-AC120V-F
HC2E-HP-AC200V-F
HC2E-HP-AC240V-F
HC2E-HP-DC6V-F
HC2E-HP-DC12V-F
HC2E-HP-DC24V-F
HC2E-HP-DC48V-F
HC2E-HP-DC100V-F
4 Form C
Part No.
HC4E-HP-AC6V
HC4E-HP-AC12V
HC4E-HP-AC24V
HC4E-HP-AC48V
HC4E-HP-AC100V
HC4E-HP-AC120V
HC4E-HP-AC200V
HC4E-HP-AC240V
HC4E-HP-DC6V
HC4E-HP-DC12V
HC4E-HP-DC24V
HC4E-HP-DC48V
HC4E-HP-DC100V
4 Form C (twin)
Part No.
HC4ED-HP-AC6V
HC4ED-HP-AC12V
HC4ED-HP-AC24V
HC4ED-HP-AC48V
HC4ED-HP-AC100V
HC4ED-HP-AC120V
HC4ED-HP-AC200V
HC4ED-HP-AC240V
HC4ED-HP-DC6V
HC4ED-HP-DC12V
HC4ED-HP-DC24V
HC4ED-HP-DC48V
HC4ED-HP-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2) Plug-in type (With LED indication)
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1E-L-AC6V-F
HC1E-L-AC12V-F
HC1E-L-AC24V-F
HC1E-L-AC48V-F
HC1E-L-AC100V-F
HC1E-L-AC120V-F
HC1E-L-AC200V-F
HC1E-L-AC240V-F
HC1E-L-DC6V-F
HC1E-L-DC12V-F
HC1E-L-DC24V-F
HC1E-L-DC48V-F
HC1E-L-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
3) PC board type
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1E-HP-AC6V-F
HC1E-HP-AC12V-F
HC1E-HP-AC24V-F
HC1E-HP-AC48V-F
HC1E-HP-AC100V-F
HC1E-HP-AC120V-F
HC1E-HP-AC200V-F
HC1E-HP-AC240V-F
HC1E-HP-DC6V-F
HC1E-HP-DC12V-F
HC1E-HP-DC24V-F
HC1E-HP-DC48V-F
HC1E-HP-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” in the suffix of part number when ordering the PC board type 0.9 mm width terminal. (4 Form C, 4 Form C (twin) only)
–5–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
4) PC board type (With LED indication)
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1E-PL-AC6V-F
HC1E-PL-AC12V-F
HC1E-PL-AC24V-F
HC1E-PL-AC48V-F
HC1E-PL-AC100V-F
HC1E-PL-AC120V-F
HC1E-PL-AC200V-F
HC1E-PL-AC240V-F
HC1E-PL-DC6V-F
HC1E-PL-DC12V-F
HC1E-PL-DC24V-F
HC1E-PL-DC48V-F
HC1E-PL-DC100V-F
2 Form C
Part No.
HC2E-PL-AC6V-F
HC2E-PL-AC12V-F
HC2E-PL-AC24V-F
HC2E-PL-AC48V-F
HC2E-PL-AC100V-F
HC2E-PL-AC120V-F
HC2E-PL-AC200V-F
HC2E-PL-AC240V-F
HC2E-PL-DC6V-F
HC2E-PL-DC12V-F
HC2E-PL-DC24V-F
HC2E-PL-DC48V-F
HC2E-PL-DC100V-F
4 Form C
Part No.
HC4E-PL-AC6V
HC4E-PL-AC12V
HC4E-PL-AC24V
HC4E-PL-AC48V
HC4E-PL-AC100V
HC4E-PL-AC120V
HC4E-PL-AC200V
HC4E-PL-AC240V
HC4E-PL-DC6V
HC4E-PL-DC12V
HC4E-PL-DC24V
HC4E-PL-DC48V
HC4E-PL-DC100V
4 Form C (twin)
Part No.
HC4ED-PL-AC6V
HC4ED-PL-AC12V
HC4ED-PL-AC24V
HC4ED-PL-AC48V
HC4ED-PL-AC100V
HC4ED-PL-AC120V
HC4ED-PL-AC200V
HC4ED-PL-AC240V
HC4ED-PL-DC6V
HC4ED-PL-DC12V
HC4ED-PL-DC24V
HC4ED-PL-DC48V
HC4ED-PL-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” in the suffix of part number when ordering the PC board type 0.9 mm width terminal. (4 Form C, 4 Form C (twin) only)
5) TM type
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1E-HTM-AC6V-F
HC1E-HTM-AC12V-F
HC1E-HTM-AC24V-F
HC1E-HTM-AC48V-F
HC1E-HTM-AC100V-F
HC1E-HTM-AC120V-F
HC1E-HTM-AC200V-F
HC1E-HTM-AC240V-F
HC1E-HTM-DC6V-F
HC1E-HTM-DC12V-F
HC1E-HTM-DC24V-F
HC1E-HTM-DC48V-F
HC1E-HTM-DC100V-F
2 Form C
Part No.
HC2E-HTM-AC6V-F
HC2E-HTM-AC12V-F
HC2E-HTM-AC24V-F
HC2E-HTM-AC48V-F
HC2E-HTM-AC100V-F
HC2E-HTM-AC120V-F
HC2E-HTM-AC200V-F
HC2E-HTM-AC240V-F
HC2E-HTM-DC6V-F
HC2E-HTM-DC12V-F
HC2E-HTM-DC24V-F
HC2E-HTM-DC48V-F
HC2E-HTM-DC100V-F
4 Form C
Part No.
HC4E-HTM-AC6V
HC4E-HTM-AC12V
HC4E-HTM-AC24V
HC4E-HTM-AC48V
HC4E-HTM-AC100V
HC4E-HTM-AC120V
HC4E-HTM-AC200V
HC4E-HTM-AC240V
HC4E-HTM-DC6V
HC4E-HTM-DC12V
HC4E-HTM-DC24V
HC4E-HTM-DC48V
HC4E-HTM-DC100V
4 Form C (twin)
Part No.
HC4ED-HTM-AC6V
HC4ED-HTM-AC12V
HC4ED-HTM-AC24V
HC4ED-HTM-AC48V
HC4ED-HTM-AC100V
HC4ED-HTM-AC120V
HC4ED-HTM-AC200V
HC4ED-HTM-AC240V
HC4ED-HTM-DC6V
HC4ED-HTM-DC12V
HC4ED-HTM-DC24V
HC4ED-HTM-DC48V
HC4ED-HTM-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
4. With diode type (For DC)
1) Plug-in type
Nominal coil voltage
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-DC6V-D-F
HC1-DC12V-D-F
HC1-DC24V-D-F
HC1-DC48V-D-F
HC1-DC100V-D-F
2 Form C
Part No.
HC2-DC6V-D-F
HC2-DC12V-D-F
HC2-DC24V-D-F
HC2-DC48V-D-F
HC2-DC100V-D-F
3 Form C
Part No.
HC3-DC6V-D-F
HC3-DC12V-D-F
HC3-DC24V-D-F
HC3-DC48V-D-F
HC3-DC100V-D-F
4 Form C
Part No.
HC4-DC6V-D
HC4-DC12V-D
HC4-DC24V-D
HC4-DC48V-D
HC4-DC100V-D
4 Form C (twin)
Part No.
HC4D-DC6V-D
HC4D-DC12V-D
HC4D-DC24V-D
HC4D-DC48V-D
HC4D-DC100V-D
2 Form C
Part No.
HC2-L-DC6V-D-F
HC2-L-DC12V-D-F
HC2-L-DC24V-D-F
HC2-L-DC48V-D-F
HC2-L-DC100V-D-F
3 Form C
Part No.
HC3-L-DC6V-D-F
HC3-L-DC12V-D-F
HC3-L-DC24V-D-F
HC3-L-DC48V-D-F
HC3-L-DC100V-D-F
4 Form C
Part No.
HC4-L-DC6V-D
HC4-L-DC12V-D
HC4-L-DC24V-D
HC4-L-DC48V-D
HC4-L-DC100V-D
4 Form C (twin)
Part No.
HC4D-L-DC6V-D
HC4D-L-DC12V-D
HC4D-L-DC24V-D
HC4D-L-DC48V-D
HC4D-L-DC100V-D
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2) Plug-in type (with LED indication)
Nominal coil voltage
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-L-DC6V-D-F
HC1-L-DC12V-D-F
HC1-L-DC24V-D-F
HC1-L-DC48V-D-F
HC1-L-DC100V-D-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
* Sockets and mounting boards available
–6–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
RATING
1. Standard type
1) Coil data
(1) AC coils (50/60Hz)
Type
Nominal coil
voltage
Pick-up voltage*
(at 20°C 68°F)
Drop-out
voltage*
(at 20°C 68°F)
6V AC
Standard
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
80%V or less of
nominal voltage
(Initial)
30%V or more
of nominal
voltage
(Initial)
Nominal coil current
[±20%] (at 20°C 68°F)
Coil inductance
50Hz
60Hz
N.C.
condition
N.O.
condition
224mA
200mA
0.078H
0.074H
111mA
56mA
28mA
13.4/14.7mA
12.2/13.5mA
6.7/7.4mA
100mA
50mA
25mA
12/13.2mA
10.9/11.9mA
6/6.6mA
0.312H
1.243H
4.974H
23.75H
27.19H
85.98H
0.295H
1.181H
4.145H
20.63H
25.57H
81.76H
Nominal operating
power
50Hz
60Hz
1.3VA
1.2VA
Max. applied
voltage
(at 70°C 158°F)
110%V of
nominal voltage
* Square, pulse drive
Notes: 1. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage. In particular, for AC operation, if the applied voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will flow
leading possibly to coil burnout.
2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
(2) DC coils
Type
Nominal coil
voltage
Pick-up voltage*
(at 20°C 68°F)
Drop-out voltage*
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
6V DC
Standard
12V DC
24V DC
48V DC
100/110V DC
Nominal coil current
[±10%]
(at 20°C 68°F)
150mA
Coil resistance
[±10%]
(at 20°C 68°F)
40Ω
75mA
37mA
18.5mA
10/11mA
160Ω
650Ω
2,600Ω
10,000Ω
Nominal operating
power
Max. applied voltage
(at 70°C 158°F)
0.9W
110%V of
nominal voltage
1.0W
* Square, pulse drive
Notes: 1. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature.
2. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
3. For use with 200 V DC, connect a 10 KΩ (5W) resistor, in series, to the 100 V DC relay.
4. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
–7–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
2) Specifications
Characteristics
Contact
Rating
Electrical
characteristics
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity
(resistive load)
Max. switching power
(resistive load)
Max. switching voltage
Max. switching current*4
Min. switching capacity
(Reference value)*1
Insulation resistance (Initial)
Breakdown
voltage
(Initial)
10A 250V AC
7A 250V AC
7A 250V AC
5A 250V AC
3A 250V AC
2,500VA
1,750VA
1,750VA
1,250VA
750VA
7A
250VAC
7A
5A
3A
10A
1mA 1V DC
Between open
contacts
Between contact
sets
Between contact
and coil
700 Vrms for 1min. (Detection current: 10mA.)
700 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Shock
resistance
Functional
Destructive
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration
resistance
Functional
Destructive
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 2 mm
Min. 5×107: AC coil type (at 180 times/min.); Min. 108: DC coil type (at 180 times/min.)
Min. 2×105
Min. 2×105
Min. 105
Min. 2×105
Min. 2×105
resistive load
resistive load
resistive load
resistive load
resistive load
(at 20 times/min.)
(at 20 times/min.)
(at 20 times/min.)
(at 20 times/min.)
(at 20 times/min.)
Ambient temperature: –50 to +70°C –58 to +158°F (without LED); –50 to +60°C –58 to +140°F (with LED)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Approx. 30g 1.06 oz
Mechanical
Expected life
Conditions
100μA 1V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Operate time
(initial, at 20°C 68°F)*2
Release time
(initial, at 20°C 68°F)*2
Mechanical
characteristics
Specifications
2 Form C
3 Form C
4 Form C
4 Form C (twin)
Max. 30 mΩ (By voltage drop 6 V DC 1A)
Ag alloy (cd free) + Au flash
AgNi type + Au clad
1 Form C
Electrical
Conditions for operation,
transport and storage*3
Unit weight
Notes: *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. For the ambient temperature, refer to “NOTES”.
*4. When using the socket and terminal socket, be sure to verify the max. continuous current.
3) Switching capacity and expected life
(1) Electrical (at 20 times/min.)
Load
AC
Resistive (cos ϕ = 1)
Voltage
125V AC
10A
250V AC
10A
1 Form C
7A
5A
7A
5A
3A
7A
—
5A
5A
3A
2A
3A
7A
5A
7A
5A
3A
7A
—
5A
5A
3A
2A
3A
2 Form C
3 Form C
4 Form C
4 Form C (twin)
DC
Inductive (cos ϕ 0.4)
125V AC
250V AC
5A
3A
3A
2A
3.5A
2.5A
1.5A
—
3.5A
—
2A
1A
0.5A
1A
2.5A
1.5A
2A
1.5A
1A
—
2A
—
1A
0.8A
0.4A
0.8A
Resistive
30V DC
—
Inductive
30V DC
—
Expected life
3A
—
—
3A
—
—
—
3A
—
3A
—
3A
1A
—
—
0.6A
—
—
—
0.4A
—
0.4A
—
—
Min. 5×105
Min. 106
Min. 2×105
Min. 5×105
Min. 106
Min. 105
Min. 2×105
Min. 5×105
Min. 2×105
Min. 5×105
Min. 106
Min. 2×105
Min. 2×105
(2) Mechanical (at 180 times/min.)
AC coil type: Min. 5×107; DC coil type: Min. 108
–8–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
2. Amber sealed type
1) Coil data
Same coil data as HC relay standard type. Please refer to standard type information.
2) Specifications
Characteristics
Contact
Item
1 Form C
1 Form C
5A 250V AC
1,250VA
250VAC
5A
Arrangement
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Rating
Expected life
4 Form C (twin)
4 Form C
1A 250V AC
250VA
250VAC
1A
1mA 100mV DC
100μA 100mV DC
Min. 2×105 resistive load (at 20 times/min.)
Ambient temperature: –40°C to +60°C –40°F to +140°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Electrical
Conditions for operation, transport and
storage*2
Conditions
Specifications
2 Form C
4 Form C
2 Form C
4 Form C
3A 250V AC
2A 250V AC
700VA
500VA
250VAC
250VAC
3A
2A
Notes: Other specifications are same as standard types.
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the ambient temperature, refer to “NOTES”.
3) Switching capacity and expected life
(1) Electrical (at 20 times/min.)
AC
Load
Voltage
HC1E
HC2E
HC4E
HC4ED (4 Form C twin)
Resistive (cos ϕ = 1)
125V AC
250V AC
5A
5A
3A
3A
2A
2A
1A
1A
DC
Inductive (cos ϕ 0.4)
125V AC
250V AC
—
—
—
—
—
—
—
—
Resistive
30V DC
3A
2A
2A
—
Inductive
30V DC
1A
0.7A
0.6A
—
Expected life
Min. 2×105
Min. 2×105
Min. 2×105
Min. 2×105
(2) Mechanical (at 180 times/min.)
AC coil type: Min. 5×107; DC coil type: Min. 108
3. With diode type (For DC)
1) Coil data
Same coil data as HC relay standard type for DC. Please refer to standard type information.
Please connect DC coil type built-in diode correctly by verifying the coil polarity.
2) Specifications
Characteristics
Conditions
Item
Conditions for operation, transport and storage*
Specifications
Ambient temperature: –50°C to +60°C –58°F to +140°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Notes: Other specifications are same as standard type HC relay. Please see the standard type HC relay.
* For the ambient temperature, refer to “NOTES”.
–9–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
REFERENCE DATA
Standard type
2.-(1) Max. switching capacity
(single contact type)
Load: 250 V AC resistive load
10
5,000
Mechanical life (AC type)
500
400
1c
300
100
(250 V AC cosϕ = 1)
3
1c, 2c, 3c, 4c
AC
resistive
load
0.4
2c
3
DC
resistive
load
0.4
4c
4
6
8
0.1
10
10
30
3.-(1) Coil temperature rise
(1 Form C, AC type)
Measured portion: Inside the coil
Ambient temperature: 25°C 77°F
0.1
10
125 250
Contact voltage, V
Load current, A
3.-(2) Coil temperature rise
(2 Form C, AC type)
(See note.)
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
100
90
90
80
10A
70
7A
5A
2A
0A
60
50
40
Temperature rise, °C
100
(See note.)
10A
80
5A
70
0A
60
50
40
80
50
40
20
10
10
0
0
80
90
100
110
0
120
0A
60
10
120
5A
70
30
110
7A
90
20
100
80
Coil applied voltage, %V
Coil applied voltage, %V
90
100
Measured portion: Inside the coil
Ambient temperature: 15 to 21°C 59 to 70°F
(See note.)
Measured portion: Inside the coil
Ambient temperature: 29°C 84°F
Measured portion: Inside the coil
Ambient temperature: 29°C 84°F
120
5A
100
3A
80
1A
100
100
90
90
80
70
60
10A
5A
0A
50
40
60
40
30
20
20
20
10
10
0
0
100
110
120
80
90
100
110
120
Coil applied voltage, %V
3.-(7) Coil temperature rise
(3 Form C, DC type)
3.-(8) Coil temperature rise
(4 Form C, DC type)
Measured portion: Inside the coil
Ambient temperature: 29°C 84°F
Measured portion: Inside the coil
Ambient temperature: 17 to 18°C 62 to 64°F
100
90
90
80
7A
70
5A
60
0A
50
40
Temperature rise, °C
100
0
80
90
100
110
120
Coil applied voltage, %V
Note: Coil temperature rise
80
When the nominal voltage is applied to 120 or 240 V
AC coil types respectively, the figures of coil
temperature rise increase by approx. 10 degrees to
the ones shown on each graph.
5A
70
60
3A
1A
50
40
30
30
20
20
10
5A
0A
50
40
90
7A
70
30
80
120
80
60
Coil applied voltage, %V
Temperature rise, °C
Temperature rise, °C
140
Temperature rise, °C
3.-(6) Coil temperature rise
(2 Form C, DC type)
Temperature rise, °C
3.-(5) Coil temperature rise
(1 Form C, DC type)
160
110
Coil applied voltage, %V
3.-(4) Coil temperature rise
(4 Form C, AC type)
180
(See note.)
100
20
90
125 250
Contact voltage, V
Measured portion: Inside the coil
Ambient temperature: 18°C 64°F
30
80
30
3.-(3) Coil temperature rise
(3 Form C, AC type)
30
0
AC
resistive
load
3c
2
Temperature rise, °C
4c
DC
resistive
load
Temperature rise, °C
200
1c
2c, 3c
7
5
Mechanical life (DC type)
Contact current, A
Life, ×104 times
10,000
2.-(2) Max. switching capacity
[4-pole bifurcated (twin) contact type]
Contact current, A
1. Life curve
10
80
90
100
110
120
Coil applied voltage, %V
0
80
90
100
110
120
Coil applied voltage, %V
–10–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
Amber sealed type
1.-(1) Max. switching capacity
(single contact type)
1.-(2) Max. switching capacity
[4-pole bifurcated (twin) contact type]
2.-(1) Coil temperature rise (1 Form C AC type)
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
3
1c
1c, 2c, 3c, 4c
AC
resistive
load
2c
2
1c
4c
2c, 4c
0.4
1
AC
resistive
load
0.4
Temperature rise, °C
Contact current, A
5
Contact current, A
100
80
70
5A
60
50
40
30
20
DC resistive load
DC resistive load
90
10
0.1
10
30
0.1
10
125 250
Contact voltage, V
30
0
125 250
Contact voltage, V
80
90
100
110
120
Voltage applied to coil, %V
2.-(3) Coil temperature rise (4 Form C AC type)
2.-(4) Coil temperature rise (1 Form C DC type)
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
100
100
90
90
80
70
3A
60
50
40
(See note.)
100
90
2A
80
70
60
50
40
80
70
60
50
30
30
20
20
20
10
10
10
0
0
80
90
100
110
120
Voltage applied to coil, %V
80
90
100
110
120
Voltage applied to coil, %V
Note: Coil temperature rise
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
When the nominal voltage is applied to 120 or 240 V
AC coil types respectively, the figures of coil
temperature rise increase by approx. 10 degrees to
the ones shown on each graph.
100
90
5A
0A
40
30
2.-(5) Coil temperature rise (2 Form C DC type)
Temperature rise, °C
Temperature rise, °C
(See note.)
Temperature rise, °C
Temperature rise, °C
2.-(2) Coil temperature rise (2 Form C AC type)
0
80
90
100
110
120
Voltage applied to coil, %V
80
70
60
5A
50
40
30
20
10
0
80
90
100
110
120
Voltage applied to coil, %V
With diode type (For DC)
1.-(1) DC coil surge voltage waveform
(without diode)
1.-(2) DC coil surge voltage waveform
(with diode)
Diode characteristics;
Reverse breakdown voltage: 1,000V,
Forward current: 1A
ON
OFF
ON
OFF
260V
+
+
12V DC
–
12V DC
To digital
memory
–
To digital
memory
breakdown voltage: 1,000 V
(Reverse
(
Forward current: 1 A
–11–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
Standard type
1) Plug-in type
1 Form C
External dimensions
CAD Data
20.8
.819
1.7
.067
1.7
.067
Schematic (Bottom view)
Without LED indication type
(AC/DC)
27.2
1.071
0.6
.024
2
35.2
1.386
2
7
12
13
14
14
LED AC type
6.4
.252
2
12
13
1
.039
2.54
.100
13.35
.526
4.45
4.41
.175
.174
7
LED DC type
2
7
0.5
.020
13
( )
∼
4.06
.160
6.35
.250
6.35
.250
7
12
13
14
( )
∼
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
12
14
(+)
(−)
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
2 Form C
External dimensions
CAD Data
20.8
.819
1.7
.067
1.7
.067
Schematic (Bottom view)
Without LED indication type
(AC/DC)
27.2
1.071
0.6
.024
1
5
9
13
35.2
1.386
1
.039
1
4
5
8
9
12
13
14
14
LED AC type
6.4
.252
2.54
.100
4.41
13.35
.174
.526
4
8
12
1
5
9
13
( )
0.5
.020
∼
4.06
.160
6.35
.250
6.35
.250
LED DC type
4
8
12
1
5
9
13
14
( )
∼
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
4
8
12
14
(+)
(−)
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
3 Form C
External dimensions
CAD Data
20.8
.819
1.7
.067
1.7
.067
0.6
.024
Schematic (Bottom view)
Without LED indication type
(AC/DC)
27.2
1.071
2
3
5
6
7
8
9
13
14
9
6
14
LED AC type
6.4
.252
4
3
5
8
13
1
.039
1
2
4
7
35.2
1.386
2.54
.100
4.41
13.35
.174
.526
1
0.5
.020
1
2
3
1
2
3
4
5
8
6
4
9
7
5
8
9
7
13
( )
4.06
.160
6.35
.250
6.35
.250
∼
14
( )
∼
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
–12–
LED DC type
13
(−)
6
14
(+)
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
4 Form C and 4-pole bifurcated (twin)
External dimensions
CAD Data
20.8
.819
1.7
.067
1.7
.067
Schematic (Bottom view)
Without LED indication type
(AC/DC)
27.2
1.071
0.6
.024
35.2
1.386
1
2
3
4
5
6
7
8
9
10
11
12
13
0.5
.020
13
( )
4.06
.160
6.35
.250
6.35
.250
14
3
4
6
7
8
9
10
11
12
14
LED AC type
6.4
.252
4.45
.175
2
5
13
1
.039
2.54
.100
4.41
13.35
.174
.526
1
∼
LED DC type
1
2
3
4
1
2
3
4
5
6
7
8
5
6
7
8
9
10
11
12
9
10
11
12
14
( )
13
∼
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
(−)
14
(+)
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
2) PC board type
4 Form C
External dimensions
CAD Data
20.8
.819
1.7
.067
1.7
.067
The diagrams show the external dimensions of
the 4 Form C and 4-pole bifurcated (twin) types.
For 1 Form C, 2 Form C, and 3 Form C, see
diagrams at plug-in types (only the terminals are
different).
Types with 0.9 mm .035 inch terminal width are
also available.
27.2
1.071
0.6
.024
35.2
1.386
1
.039
1.5
.059
13.35
.526
4.45
.175
1.5
.059
0.5
.020
4.41
.174
1
2
3
4
5
6
7
8
9
10
11
13
3.5
.138
12
14
4.06
.160
6.35
.250
6.35
.250
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
PC board pattern
1 Form C
Schematic
2 Form C
10.4
.409
16.8
.661
8.9
.350
13.35
.526
5-2 dia. hole
5-.079 dia.
3 Form C
4.1
.161
4.1
.161
4.45
.175
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
8-2 dia. hole
8-.079 dia.
10.4
.409
16.8
.661
10.4
.409
16.8
.661
13.35
.526
Same schematic as plug-in type HC relay
4.1
.161
4.1
.161
10.4
.409
16.8
.661
13.35
.526
4 Form C
11-2 dia. hole
11-.079 dia.
4.45
.175
8.9
.350
13.35
.526
14-2 dia. hole
14-.079 dia.
Tolerance: ±0.1 ±.004
–13–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
3) TM type
4 Form C
External dimensions
CAD Data
20.6
.811
43
1.693
The diagrams show the external dimensions of
the 4 Form C and 4-pole bifurcated (twin) types.
For 1 Form C, 2 Form C, and 3 Form C, see
diagrams at plug-in types (only the terminals are
different).
2
.079
34.2
1.346
1
.039
3.6
.142
13.35
.526
4.45
.175
1
2
3
Schematic
Same schematic as plug-in type HC relay
Be aware that there is no LED indicator with
built-in diode types.
4.31
.170
4
5
6
7
8
9
10
11
12
13
Chassis (Panel) cutout
6.4
.252
2.54
0.5
.100 .020
14
4.06
.160
37.6
6.35 27 1.480
.250 1.063
6.35
.250
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
Chassis (Panel) cutout in tandem mounting
23
.906
2-3.6 dia.
2-.142 dia.
37.6
1.480
Tolerance: ±0.1 ±.004
37.6
1.480
21
.827
2
.079
21
.827
Notes: 1. In mounting, use M3 screws and M3 washers.
2. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover.
3. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm).
Moreover, use washers to prevent loosening.
–14–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
Amber sealed type
1) Plug-in type
1 Form C
External dimensions
CAD Data
Schematic (Bottom view)
Without LED indication type
(AC/DC)
27.4
1.079
2
21.0
.827
7
12
Indication of DC coil
indicates only with
LED indication type
13
14
LED AC type
35.2
1.386
LED DC type
2
2
14
6.4
.252
0.5
.020
4.06 .160
4.51 .178
7
7
13
2.54
.100
12
(~)
14
(~)
13
12
(+)
14
(−)
13
6.35 .250
6.35 .250
(12)
(14)
(7)
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
13.35
.526
(2)
(13)
4.45
.175
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
2 Form C
External dimensions
CAD Data
Schematic (Bottom view)
Without LED indication type
(AC/DC)
27.4
1.079
21.0
.827
Indication of DC coil
indicates only with
LED indication type
14
4.06 .160
4.51 .178
4
8
9
12
13
14
LED AC type
35.2
1.386
13
2.54
.100
6.4
.252
0.5
.020
1
5
LED DC type
1
5
4
8
1
5
4
8
9
(~)
13
12
(~)
14
9
(−)
13
12
(+)
14
6.35 .250
6.35 .250
(4) (8) (12)
(14)
(1) (5)
(13)
(9)
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
13.35
.526
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
4 Form C and 4-pole bifurcated (twin)
External dimensions
CAD Data
Schematic (Bottom view)
Without LED indication type
(AC/DC)
27.4
1.079
1
5
21.0
.827
2
6
3
7
4
8
9 10 11 12
Indication of DC coil
indicates only with
LED indication type
14
6.4
.252
4.06 .160
4.51 .178
14
LED AC type
35.2
1.386
0.5
.020
13
1
5
13
2.54
.100
2
6
3
7
LED DC type
1
5
4
8
2
6
3
7
4
8
9 10 11 12
(−)
(+)
13
14
9 10 11 12
(~)
(~)
13
14
6.35 .250
6.35 .250
(4) (8)
(12)
(14)
(3) (7) (11)
(2) (6) (10)
(1) (5)
(9)
(13)
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
13.35
.526
4.45
.175
–15–
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
2) PC board type
4 Form C and 4-pole bifurcated (twin)
External dimensions
CAD Data
27.4
1.079
21.0
.827
Indication of DC coil
indicates only with
LED indication type
35.2
1.386
Schematic
14
4.06 .160
4.51 .178
Same schematic as plug-in type HC relay
13
5
.197
0.5
.020
The diagrams show the external dimensions of
the 4 Form C and 4-pole bifurcated (twin) types.
For 1 Form C, 2 Form C, and 3 Form C, see
diagrams at plug-in types (only the terminals are
different).
Types with 0.9 mm .035 inch terminal width are
also available.
1.5
.059
3.5
.138
6.35 .250
6.35 .250
(4) (8)
(12)
(14)
(3) (7) (11)
(1) (5)
(9)
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
13.35
.526
(2) (6) (10)
(13)
4.45
.175
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
PC board pattern
6.35 .250
6.35 .250
4.45
.175
4.06
.160
13.35
.526
14-2 dia. hole
14-.079 dia. hole
Tolerance: ±0.1 ±.004
3) TM type
4 Form C and 4-pole bifurcated (twin)
External dimensions
CAD Data
The diagrams show the external dimensions of
the 4 Form C and 4-pole bifurcated (twin) types.
For 1 Form C, 2 Form C, and 3 Form C, see
diagrams at plug-in types (only the terminals are
different).
2
.079
34.5
1.358
0.5
.020
43.0
1.693
37.6
1.480
27.6
1.087
4.06 .160
4.61 .181
4 8 12
3 7 11
2.54
.100
6.35 .250
6.35 .250
R1
R . .8
071
9 13
Schematic
Same schematic as plug-in type HC relay
Be aware that there is no LED indicator with
built-in diode types.
Chassis (Panel) cutout in tandem mounting
14
2 6 10
1 5
6.4
.252
13.35 21.0
.526 .827
23
.906
3.6 4.45
.142 .175
37.6
1.480
21
.827
2
.079
Chassis (Panel) cutout
21
.827
2-3.6 dia.
2-.142 dia.
37.6
1.480
Tolerance: ±0.1 ±.004
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
Notes: 1. In mounting, use M3 screws and M3 washers.
2. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover.
3. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm).
Moreover, use washers to prevent loosening.
–16–
ASCTB4E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HC
With diode type (For DC)
Same dimensions as HC relay standard/plug-in type
Schematic
CAD Data
Without LED indicator
With LED indicator
1
2
3
4
1
2
3
5
6
7
8
5
6
7
8
9
10
11
12
9
10
11
12
13−
+14
13−
4
+14
LED
Protection (surge-absorbing) diode
Protection (surge-absorbing) diode
SAFETY STANDARDS
Item
1 Form C
UL/C-UL (Recognized)
File No.
Contact rating
E43028
10A 250V AC
1/3HP 125, 250V AC
3A 30V DC
E43028
HC
Standard
3 Form C
4 Form C
4 Form C twin
1 Form C
2 Form C
E43028
4 Form C twin
1 Form C
2 Form C
HC with
diode type
3 Form C
(For DC)
4 Form C
4 Form C twin
LR26550
etc.
7A 250V AC
/ HP 125, 250V AC
3A 30V DC
5A 250V AC
1/10HP 125, 250V AC
3A 30V DC
3A 250V AC
3A 30V DC
6A 250V AC
1/6HP 125, 250V AC
3A 30V DC
4A 250V AC
1/10HP 125, 250V AC
3A 30V DC
2A 250V AC
1/20HP 125, 250V AC
2A 30V DC
1A 250V AC
1A 30V DC
10A 250V AC
1/3HP 125, 250V AC
3A 30V DC
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
5A 250V AC
1/10HP 125, 250V AC
3A 30V DC
3A 250V AC
3A 30V DC
LR26550
etc.
16
E43028
E43149
E43028
E43028
HC Amber
4 Form C
7A 250V AC
/ HP 125, 250V AC
3A 30V DC
16
2 Form C
E43028
E43149
E43028
E43028
E43028
E43028
E43149
File No.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
CSA (Certified)
Contact rating
10A 250V AC
1/3HP 125, 250V AC
3A 30V DC
7A 250V AC
/ HP 125, 250V AC
3A 30V DC
File No.
40017406
40017406
16
7A 250V AC
/ HP 125, 250V AC
3A 30V DC
5A 250V AC
1/10HP 125, 250V AC
3A 30V DC
3A 250V AC
3A 30V DC
6A 250V AC
1/6HP 125, 250V AC
3A 30V DC
4A 250V AC
1/10HP 125, 250V AC
3A 30V DC
2A 250V AC
1/20HP 125, 250V AC
2A 30V DC
1A 250V AC
1A 30V DC
10A 250V AC
1/3HP 125, 250V AC
3A 30V DC
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
5A 250V AC
1/10HP 125, 250V AC
3A 30V DC
3A 250V AC
3A 30V DC
—
16
40017406
VDE (Certified)
Contact rating
10A 250V AC (cosφ =1.0)
3A 250V AC (cosφ =0.4)
3A 30V DC (0ms)
7A 250V AC (cosφ =1.0)
2A 250V AC (cosφ =0.4)
3A 30V DC (0ms)
—
5A 65V AC (cosφ =1.0)
3A 65V AC (cosφ =0.4)
3A 30V DC (0ms)
TV rating (UL/CSA)
File No.
Rating
UL
TV-3
E43149
CSA
LR26550
UL
TV-3
E43149
CSA
LR26550
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Remarks
NOTES
1. For cautions for use, please read
“General Application Guidelines”.
2. Diode characteristics
1) Reverse breakdown voltage: 1,000 V
2) Forward current: 1 A
3. Diode type
Since the diode inside the relay coils are
designed to absorb the counter emf, the
element may be damaged if a large
surge, etc., is applied to the diode. If
there is the possibility of a large surge
voltage from the outside, please
implement measures to absorb it.
–17–
4. Please connect DC coil types with
LED and built-in diode correctly by
verifying the coil polarity (“+” and “–
”). Connecting with reverse polarity
will cause the LED not to light and
damage the built-in diode due to its
specification.
ASCTB4E 201709-T