0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HC3-DC24V-D-F

HC3-DC24V-D-F

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    RELAYGENPURPOSE3PDT7A24V

  • 数据手册
  • 价格&库存
HC3-DC24V-D-F 数据手册
HC Has built-in diode to absorb surge For use in semiconductor circuits HC RELAY WITH DIODE TYPE (FOR DC) FEATURES 1. The built-in diode absorbs surge voltage arising when the coil goes to the off state (for DC type). Diode characteristics; Reverse breakdown voltage: 1,000V, Forward current: 1A 2. With LED indicator type also available 3. UL, CSA approval is standard Compliance also with Japanese Electrical Appliance and Material Control Law. TYPICAL APPLICATIONS Compliance with RoHS Directive Suitable for factory automation equipment and automotive devices 1. Control panels, power supply equipment, molding equipment, machine tools, welding equipment, agricultural equipment, etc. 2. Office equipment, automatic vending machines, telecommunications equipment, disaster prevention equipment, copiers, measuring devices, medical equipment, amusement devices, etc. 3. All types of household appliance About Cd-free contacts We have introduced Cadmium free type products to reduce Environmental Hazardous Substances. (The suffix “F” should be added to the part number. The Suffix “F” is required only for 1 Form C, 2 Form C, 3 Form C contact type. The 4 Form C and 4 Form C bifurcated (twin) contact type is originally cadmium-free, the suffix “F” is not required.) Please replace parts containing Cadmium with Cadmium-free products and evaluate them with your actual application before use because the life of a relay depends on the contact material and load. TYPES 1) Plug-in type Coil voltage 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1-DC6V-D-F HC1-DC12V-D-F HC1-DC24V-D-F HC1-DC48V-D-F HC1-DC100V-D-F 2 Form C Part No. HC2-DC6V-D-F HC2-DC12V-D-F HC2-DC24V-D-F HC2-DC48V-D-F HC2-DC100V-D-F 3 Form C Part No. HC3-DC6V-D-F HC3-DC12V-D-F HC3-DC24V-D-F HC3-DC48V-D-F HC3-DC100V-D-F 4 Form C Part No. HC4-DC6V-D HC4-DC12V-D HC4-DC24V-D HC4-DC48V-D HC4-DC100V-D 4 Form C (twin) Part No. HC4D-DC6V-D HC4D-DC12V-D HC4D-DC24V-D HC4D-DC48V-D HC4D-DC100V-D 2 Form C Part No. HC2-L-DC6V-D-F HC2-L-DC12V-D-F HC2-L-DC24V-D-F HC2-L-DC48V-D-F HC2-L-DC100V-D-F 3 Form C Part No. HC3-L-DC6V-D-F HC3-L-DC12V-D-F HC3-L-DC24V-D-F HC3-L-DC48V-D-F HC3-L-DC100V-D-F 4 Form C Part No. HC4-L-DC6V-D HC4-L-DC12V-D HC4-L-DC24V-D HC4-L-DC48V-D HC4-L-DC100V-D 4 Form C (twin) Part No. HC4D-L-DC6V-D HC4D-L-DC12V-D HC4D-L-DC24V-D HC4D-L-DC48V-D HC4D-L-DC100V-D Standard packing: Carton: 20 pcs.; Case: 200 pcs. 2) Plug-in type (with LED indication) Coil voltage 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1-L-DC6V-D-F HC1-L-DC12V-D-F HC1-L-DC24V-D-F HC1-L-DC48V-D-F HC1-L-DC100V-D-F Standard packing: Carton: 20 pcs.; Case: 200 pcs. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. HC RATING 1. Coil data (Common for standard DC coil types) 2. Specifications Characteristics Item Conditions Specifications Ambient temperature: –50°C to +60°C –58°F to +140°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Conditions for operation, transport and storage* Notes: Other specifications are same as standard types. * The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT. REFERENCE DATA 1.-(1) DC coil surge voltage waveform (without diode) 1.-(2) DC coil surge voltage waveform (with diode) Diode characteristics; Reverse breakdown voltage: 1,000V, Forward current: 1A ON OFF ON OFF 260V + + DC12V – DC12V – To digital memory To digital memory breakdown voltage: 1,000 V (Reverse ( Forward current: 1 A DIMENSIONS Same dimensions as HC relay standard/ plug-in type Schematic Without LED indicator With LED indicator 1 2 3 4 1 2 3 5 6 7 8 5 6 7 8 9 10 11 12 9 10 11 12 13− +14 13− 4 +14 LED Protection (surge-absorbing) diode Protection (surge-absorbing) diode NOTES 1. Pay attention to the polarity. 2. Diode characteristics Reverse breakdown voltage: 1,000V Forward current: 1A For Cautions for Use, see Relay Technical Information. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. HC RELAY ACCESSORIES ACCESSORIES (Sockets and Terminal sockets) HC RELAY HC RELAY SOCKETS 1. Plug-in type sockets, PC board type sockets, and wrapping type sockets are available for HC relays. 2. In the table below, the socket suitable for each type of HC relay is indicated by a black dot. 3. UL/CSA approval is standard. 4. A hold-down clip is included in the package. The fixing method is the same as for HC sockets, ordinary HC terminal sockets and HL sockets. HC/HL-LEAF-SPRING-MK Compliance with RoHS Directive SOCKET SELECTOR CHART Applicable HC relay (Plug-in type) Type No. of pole Item Standard/Bifurcated contact (DC) Part No. 1 Form C 2 Form C 3 Form C 4 Form C Keep relay Amber 4 Form C 4 Form C 2 Form C 1 Form C 2 Form C 4 Form C (twin) (twin)   1-pole HC1-socket HC1-SS-K 2-pole HC2-socket HC2-SS-K  3-pole HC3-socket HC3-SS-K  1/2/4-pole (common) HC4-socket HC4-SS-K  1-pole HC1-socket for PC board HC1-PS-K  2-pole HC2-socket for PC board HC2-PS-K  HC3-PS-K   Plug-in PC board 3-pole 1/2/4-pole (common) Wrapping 1/2/4-pole (common) HC3-socket for PC board HC4-socket for PC board               HC4-PS-K          HC4-wrapping socket HC4-WS-K          HC4-wrapping socket (spring) HC4-WS          Notes: 1. Use the retainer that is shipped with the terminal socket. 2. UL/CSA approved type is standard (except for wrapping socket). All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. HC RELAY ACCESSORIES HC RELAY TERMINAL SOCKETS 1. Ordinary terminal sockets and terminal sockets for DIN rail assembly are available. 2. In the table below, the terminal socket suitable for each type of HC relay is indicated by a black dot. 3. UL/CSA approval is standard. 4. A hold-down clip is included in the package. The fixing method is the same as for sockets. The fixing method is the same as for the HC DIN rail terminal sockets and the HL DIN terminal sockets. HC/HL-LEAF-SPRING-MK HC/HL-LEAF-SPRING-K Ordinary terminal socket Terminal sockets for DIN rail assembly For general For DIN rail Type TERMINAL SOCKET SELECTOR CHART No. of pole Item Part No. Applicable HC relay (Plug-in type) Packing quantity Carton Case Standard/Bifurcated contact (DC) 1 Form C 2 Form C 3 Form C 4 Form C Keep relay Amber 4 Form C 4 Form C 2 Form C 1 Form C 2 Form C 4 Form C (twin) (twin) 2-pole HC2-slim type DIN terminal socket HC2-SFD-S 20 pcs. 100 pcs.   2-pole HC2-DIN HC2-SFD-K 10 pcs. 100 pcs.   3-pole HC3-DIN HC3-SFD-K 5 pcs. 50 pcs.  HC4-SFD-K 10 pcs. 100 pcs.          20 pcs. 10 pcs. 200 pcs. 100 pcs.          HC3-HSF-K 5 pcs. 50 pcs. HC4-HSF-K 5 pcs. 50 pcs.    1/2/4-pole HC4-DIN high (common) terminal socket 1/2/4-pole HC3 vertical (common) terminal socket HC2-terminal 2-pole socket 3-pole HC3-high terminal socket 1/2/4-pole HC-high terminal (common) socket HC4-TSF-K HC2-SF-K              Notes: 1. Use the retainer that is shipped with the terminal socket. 2. UL/CSA approved type is standard (except for HC4-TSF-K). 3. In order to prevent breakage and disfiguring, the screw tightening torque for the terminal socket should be within the range of 0.49 to 0.69 N·m {5 to 7kgf·cm}. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. HC RELAY ACCESSORIES DIMENSIONS (Unit: mm inch) 1. Plug-in type sockets HC1-Socket (HC1-SS-K) HC2-Socket (HC2-SS-K) External dimensions External dimensions 4.45 4.45 .175 .175 4.45 .175 4.45 4.45 .175 .175 4.45 .175 1 5 2 6 3 4 7 8 9 10 11 12 13 14 29.4 1.157 25.2 .992 4.06 .160 6.35 .250 6.35 .250 1 5 2 6 3 4 7 8 9 10 11 12 7.06 .278 13 14 29.4 1.157 25.2 .992 4.06 .160 6.35 .250 6.35 .250 1.27 .050 1.27 .050 25.5 1.004 25.5 1.004 2.3 .091 2.3 .091 16.55 .652 16.55 .652 General tolerance: ±0.3 ±.012 7.65 .301 21.2 .835 HC4-Socket (HC4-SS-K) External dimensions External dimensions 25.5 1.004 13.35 .526 2 5 7 8 13 3 6 9 14 29.4 1.157 25.2 .992 21.2 .835 7.65 .301 General tolerance: ±0.3 ±.012 HC3-Socket (HC3-SS-K) 1 4 7.06 .278 29.4 29.4 4.45 4.45 .175 .175 4.45 .175 4.06 .160 9.14 .360 10.41 .410 16.76 .660 1 5 2 6 3 4 7 8 9 10 11 12 13 14 29.4 1.157 25.2 .992 4.06 .160 6.35 .250 6.35 .250 7.06 .278 1.27 .050 21.2 .835 2.3 .091 16.55 .652 General tolerance: ±0.3 ±.012 25.5 1.004 2.3 .091 16.55 .652 7.65 .301 7.65 .301 General tolerance: ±0.3 ±.012 Mounting hole diagram 21.2 .835 With a relay mounted (HC2-SS-K) Side-by-side installation 25.8 1.016 8.9 .350 25.8 1.016 21.6 .850 5.9 .232 Hold-down clip is packaged with the socket. 21.6 .850 General tolerance: ±0.2 ±.008 Notes: 1. Applicable chassis board thickness is 1.0 to 2.0 mm. 2. Installation is easy by inserting the socket from the top into the holes and by depressing the two down arrows on the retention fitting from the front. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. HC RELAY ACCESSORIES 2. PC board type sockets HC1- PC board type socket (HC1-PS-K) HC2- PC board type socket (HC2-PS-K) External dimensions 4.06 .160 1 5 2 6 3 7 4 8 9 10 11 12 13 14 29.4 1.157 25.2 .992 External dimensions 4.45 4.45 .175 .175 4.45 .175 1 5 6.35 .250 6.35 .250 2 6 3 7 4 8 9 10 11 12 7.06 .278 13 14 29.4 1.157 25.2 .992 6.35 .250 6.35 .250 1.2 .047 21.2 .835 3.95 .156 HC4- PC board type socket (HC4-PS-K) 13.35 .526 3 6 7 8 9 13 14 29.4 1.157 25.2 .992 3.95 .156 General tolerance: ±0.3 ±.012 External dimensions 2 5 21.2 .835 2 .079 13.15 .518 HC3- PC board type socket (HC3-PS-K) 1 4 7.06 .278 1.27 .050 2 .079 13.15 .518 General tolerance: ±0.3 ±.012 13.35 .526 4.06 .160 External dimensions 4.06 .160 9.14 .360 4.06 .160 1 5 10.41 .410 16.76 .660 29.4 1.157 2 6 3 7 4 8 9 10 11 12 13 14 29.4 1.157 25.2 .992 4.45 4.45 .175 .175 4.45 .175 6.35 .250 6.35 .250 7.06 .278 1.27 .050 21.2 .835 2 .079 13.15 .518 General tolerance: ±0.3 ±.012 3.95 .156 General tolerance: ±0.3 ±.012 PC board pattern (Bottom view) 21.2 .835 With a relay mounted Side-by-side installation 16.8 .661 17.95 .707 Hold-down clip is packaged with the socket. 1 Form C 2 Form C 4.1 .16110.4 .409 4.1 .16110.4 .409 4.45 .175 8.9 .350 13.35 .526 13.35 .526 8-2 dia. hole 8-.079 dia. 4 Form C 4.1 .16110.4 .409 16.8 .661 16.8 .661 5-2 dia. hole 5-.079 dia. 3 Form C 16.8 .661 13.35 .526 11-2 dia. hole 11-.079 dia. 16.8 .661 4.1 .16110.4 .409 16.8 .661 4.45 .175 8.9 .350 13.35 .526 14-2 dia. hole 14-.079 dia. 13.35 .526 9.85 .388 13.35 .526 General tolerance: ±0.2 ±.008 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 2 dia. hole .079 dia. HC RELAY ACCESSORIES 3. Wrapping type sockets Standard wrapping type sockets (HC4-WS-K) External dimensions Hold-down clip (Hold-down clip is packaged with the socket) 25.5 1.004 13.35 .526 4.45 .175 1.0±0.1 .039±.004 4.06 .160 9.14 10.41 .360 .410 16.76 .660 25.2 .992 29.4 1.157 12.4 .488 34.4 1.354 Terminal cross section 1±0.1 .039±.004 1±0.05 .039±.002 1.0±0.1 .039±.004 21.2 .835 General tolerance: ±0.3 ±.012 Note: The external and mounting dimensions are the same for 1-pole (HC1-WS-K), 2-pole (HC2-WS-K), and 3-pole (HC3-WS-K) types. Only the number of terminals varies. Wrapping type sockets with hold-down clip (HC4-WS) External dimensions Terminal cross section 1±0.1 .039±.004 1 .039 1±0.05 .039±.002 23 .906 39.3 1.547 22.0 .866 25.5 1.004 21.2 .835 1 .039 1 2 3 4 5 6 7 8 9 10 11 12 13 5 .197 25.2 .992 29.4 1.157 14 General tolerance: ±0.7 ±.028 73.7 2.902 Mounting hole diagram Side-by-side installation 25.8 1.016 8.9 .350 25.8 1.016 21.6 .850 5.9 .232 21.6 .850 General tolerance: ±0.2 ±.008 Notes: 1. Applicable chassis board thickness is 1.0 to 2.0 mm. 2. Installation is easy by inserting the socket from the top into the holes and by depressing the two down arrows on the retention fitting from the front. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. HC RELAY ACCESSORIES 4. Terminal sockets for DIN rail assembly HC2-Slim type terminal sockets for DIN rail assembly (HC2-SFD-S) External dimensions 15±0.6 .591±.024 13.35±0.2 .526±.008 M3 screw M.118 screw Schematic 4 20±0.6 .787±.024 1 8 N.C. 5 N.O. 4.1±0.2 .161±.008 57±1 2.244±.039 8±0.2 .315±.008 6.3±0.2 .248±.008 6.4±0.2 .252±.008 35.4±0.5 1.394±.020 67±1 2.638±.039 2±0.15 .079±.006 6.2±0.3 .244±.012 COM 12 9 Coil 6 .236 22±0.6 .866±.024 4.2±0.3 .165±.012 14 6±0.3 .236±.012 28.5±0.6 1.122±.024 13 General tolerance: ±0.5 ±.020 HC2-high terminal socket for DIN rail assembly (HC2-SFD-K) External dimensions 13.35±0.2 .526±.008 26±0.6 1.024±.024 M3 screw M.118 screw Schematic 1 4 N.C. 21.1±0.6 .831±.024 5 N.O. 8 4.1±0.2 .161±.008 4.2±0.3 .165±.012 6.3±0.2 .248±.008 6.4±0.2 .252±.008 67±1 2.638±.039 2±0.15 .079±.006 6 .236 COM 12 9 14 13 Coil 30±0.6 1.181±.024 General tolerance: ±0.5 ±.020 HC3-high terminal socket for DIN rail assembly (HC3-SFD-K) External dimensions 26±0.6 1.024±.024 M3 screw M.118 screw Schematic 3 2 5 4 1 N.C. 21.1±0.6 .831±.024 6 N.O. 4.06±0.2 .160±.008 4.2±0.3 .165±.012 6.35±0.2 .250±.008 6.35±0.2 .250±.008 1.27±0.15 .050±.006 67±1 2.638±.039 7 COM 9 6.2 .244 8 Coil 14 30±0.6 1.181±.024 13 General tolerance: ±0.5 ±.020 HC4-high terminal socket for DIN rail assembly (HC4-SFD-K) External dimensions 4.45±0.2 .175±.008 26±0.6 1.024±.024 13.35±0.2 .526±.008 4.1±0.2 .161±.008 M3 screw M.118 screw Schematic 4 3 2 1 8 7 6 5 N.C. 21.1±0.6 .831±.024 N.O. 4.2±0.3 .165±.012 6.3±0.2 .248±.008 6.4±0.2 .252±.008 67±1 2.638±.039 2±0.15 .079±.006 COM 12 11 10 9 Coil 14 6 .236 30±0.6 1.181±.024 General tolerance: ±0.5 ±.020 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 13 HC RELAY ACCESSORIES HC vertical type terminal socket (HC4-TSF-K) External dimensions 2-4.2×5 over hole 2-.165×.197 22±0.6 .866±.024 M3 screw M.118 screw Mounting hole diagram HC2-Slim type 9 .354 15±0.2 15±0.2 .591±.008 .591±.008 30±0.6 1.181±.024 1 8 7 6 5 12 11 10 9 4 14 13 General tolerance: ±0.5 ±.020 26 1.024 10 .394 26 1.024 67 2.638 HC vertical type Panel hole dimensions for side-by-side mounting 30 1.181 4 .157 30 1.181 Panel hole dimensions for side-by-side mounting 9.5 .374 22.5 .886 22.5 .886 59 2.323 67 2.638 33.5 1.319 22 .866 2 With a relay mounted (HC4-SFD-K) HC2, HC3 and HC4 67 2-M3.5 screw hole 2.638 (or 4.2±0.1 dia. hole) 2-M.138 screw hole 57±0.5 2.244±.020 (or .165±.004 dia. hole) 22 .866 2 .079 28.6±0.6 1.126±.024 3 67±1 2.638±.039 59±1 2.323±.039 6.2 .244 Schematic 2-M3.5 screw hole (or 4.2±0.1 dia. hole) 2-M.138 screw hole (or .165±.004 dia. hole) 30 1.181 2 .079 30 1.181 2-M3.5 screw hole (or 4.2±0.1 dia. hole) 2-M.138 screw hole (or .165±.004 dia. hole) General tolerance: ±0.1 ±.004 Hold-down clip is packaged with the terminal socket. 5. Ordinary terminal sockets HC2-terminal socket (HC2-SF-K for HC2) External dimensions 2-4.2×5 over hole 2-.165×.197 6.2 12 .244 .472 Schematic 1 5 9 13 4 8 12 14 17.5 .689 40 1.575 5 .197 M3 screw M.118 screw 15 .591 30 1.181 General tolerance: ±0.5 ±.020 HC3-high terminal socket (HC3-HSF-K) suitable for both HC2 and HC3 External dimensions Schematic 2-4.2×9 over hole 2-.165×.354 22.5 .886 1 53.5 2.106 M3 screw M.118 screw 67 2.638 6.2 .244 30 1.181 4 7 13 28.6 1.126 9 .354 8 16 .315 .630 27.8 1.094 Screw hole dimensions General tolerance: ±0.5 ±.020 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 3 6 9 2 5 8 14 HC RELAY ACCESSORIES HC4-high terminal socket (HC4-HSF-K) suitable for HC 1, 2 and 4 External dimensions 2-4.2×9 over hole 2-.165×.354 22.5 .886 53.5 2.106 M3 screw M.118 screw Schematic 28.6 1.126 1 2 6 10 5 9 13 67 2.638 6.2 .244 30 1.181 8 16 .315 .630 27.8 1.094 Screw hole dimensions 9 .354 4 8 12 3 7 11 14 General tolerance: ±0.5 ±.020 Mounting hole diagram HC2-SF-K 12 23 12 .472 .906 .472 With a relay mounted (HC2-SF-K) HC3-HSF-K and HC4-HSF-K 2-M3.5 screw hole (or 4.2±0.1 dia. hole) 2-M.138 screw hole (or .165±.004 dia. hole) 12.5 .492 22.5 .886 22.5 .886 53.5 2.106 67 2.638 40 1.575 30 1.181 30 1.181 5 .197 Panel hole dimensions for side-by-side mounting 30 1.181 30 5 1.181 .197 2-M3.5 screw hole (or 4.2±0.1 dia. hole) 2-M.138 screw hole (or .165±.004 dia. hole) Hold-down clip is packaged with the terminal socket. Panel hole dimensions for side-by-side mounting General tolerance: ±0.1 ±.004 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. MOUNTING RAIL AND FASTENING PLATE MOUNTING RAIL AND FASTENING PLATE ACCESSORIES DIMENSIONS (Unit: mm inch) Mounting rail Fastening plate ATA48011 ATA4806 1,000 39.37 12 .472 50 1.969 M4 M.157 5.5 .217 5 .197 15 .591 10 15 .394 .591 2.75R 2.75R 15 10 .591 .394 15 .591 40-5.5×15 over hole 40-.217×.591 35 24 1.378 .945 1.5 5 .059 .197 10 .394 27 1.063 7.5 .295 10 .394 UP ATA4806 Compliance with RoHS Directive MOUNTING METHOD 1. DIN terminal socket mounting 1. Enables ‘one-touch’ attachment to, and easy removal from, mounting rail (35 mm DIN46277 standard rail) on device. 2. By doing away with installation tasks, large cost savings are possible. Attachment Removal By applying pressure into the rail, secure attachment is possible. Extraction is easy when a slot head screwdriver or similar tool is used to pull outward the protrusion used for removal. 3. As well as HC relays, PDX timers, and CDX and CDF time relays can be attached. 2. Wire-pressed terminals When using wire-pressed terminals, please use the parts listed below or parts made with similar specifications. • Applicable wire-pressed terminals Part number Type Company name NICHIFU Co., Ltd. Nippon Tanshi Co., Ltd. J.S.T. Mfg Co., Ltd. Tyco Electronics AMP K.K. Fork type 1.25Y-3N, 1.25Y-3S VR1.25-3, VD1.25-3 1.25-3X, 1.25-3.7X 42413-1, 41071-A Round type 1.25-3, 1.25-3S 1.25-3, 1.25-3TA R1.25-3, R1.25-M3 42065-1, 60735-1 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HC3-DC24V-D-F 价格&库存

很抱歉,暂时无法提供与“HC3-DC24V-D-F”相匹配的价格&库存,您可以联系我们找货

免费人工找货