HC4D-HP-AC200V

HC4D-HP-AC200V

  • 厂商:

    NAIS(松下)

  • 封装:

  • 描述:

    RELAY GEN PURP 4PDT 200VAC

  • 详情介绍
  • 数据手册
  • 价格&库存
HC4D-HP-AC200V 数据手册
1c, 2c, 4c To Be Discontinued Last time buy: September 30, 2018 Standard type Amber sealed type Relay for control panel of 1A to 10A (1c/2c/3c/4c) HC RELAYS FEATURES TYPICAL APPLICATIONS 1. Standard type and Amber sealed type 2. Rich lineup includes relays with operating indication, with diode 3. Full range of types Plug-in type, PC board type and TM type 4. Sockets and terminal sockets are available. 1. Factory automation equipment and automotive devices 2. Control panels, power supply equipment, molding equipment, machine tools, welding equipment, agricultural equipment, etc. 3. Office equipment, automatic vending machines, telecommunications equipment, disaster prevention equipment, copiers, measuring devices, medical equipment, amusement devices, etc. 4. All types of household appliance With diode type RoHS compliant Protective construction: Dust cover type/ Sealed type ORDERING INFORMATION Standard type Amber sealed type HC HC Contact arrangement 1: 1 Form C 2: 2 Form C 3: 3 Form C 4: 4 Form C 4D: Bifurcated contact (twin) Contact arrangement 1: 1 Form C 2: 2 Form C 4: 4 Form C E: Amber sealed type ED: Amber sealed type bifurcated contact (twin) (Only 4 Form C) Terminal arrangement H: Plug-in type HL: Plug-in with LED indication HP: PC board type HPL: PC board with LED indication HTM: TM type Terminal arrangement H: Plug-in type L: Plug-in with LED indication HP: PC board type PL: PC board with LED indication HTM: TM type Nominal coil voltage AC: 6, 12, 24, 48, 100 (100/110), 120 (110/120), 200 (200/220), 240 (220/240) V DC: 6, 12, 24, 48, 100 (100/110) V Nominal coil voltage AC: 6, 12, 24, 48, 100 (100/110), 120 (110/120), 200 (200/220), 240 (220/240) V DC: 6, 12, 24, 48, 100 (100/110) V Contact material Contact material Contact arrangement 1 Form C 2 Form C 3 Form C 4 Form C 4-pole bifurcated (twin) AgSnO2 type Contact material AgNi type Contact material Contact arrangement 1 Form C 2 Form C 4 Form C 4-pole bifurcated (twin) F F F Nil Nil –1– AgSnO2 type AgNi type F F Nil Nil ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC With diode type (For DC) HC Contact arrangement 1: 1 Form C 2: 2 Form C 3: 3 Form C 4: 4 Form C 4D: Bifurcated contact (twin) Terminal arrangement Nil: Plug-in type L: Plug-in with LED indication Nominal coil voltage DC: 6, 12, 24, 48, 100 (100/110) V Surge suppression D: With diode Contact material Contact material Contact arrangement 1 Form C 2 Form C 3 Form C 4 Form C 4-pole bifurcated (twin) AgSnO2 type AgNi type F F F Nil Nil LINEUP Type Contact arrangement Remarks Plug-in terminal type Without LED With LED HC relay Standard type Single side stable Bifurcated (Twin) HC relay Amber sealed type Single side stable DC type with surge absorbing diode Single side stable Bifurcated (Twin) Bifurcated (Twin) PC board terminal type Without LED With LED Top mounting type (TM type) 1 Form C 2 Form C 3 Form C 4 Form C 4 Form C 1 Form C 2 Form C 4 Form C 4 Form C 1 Form C A A A A A A A A A A A A A A A A A A A A A A A A A A A A A — A A A A A A A A A — A A A A A A A A A — 2 Form C 3 Form C 4 Form C 4 Form C A A A A A A A A — — — — — — — — — — — — Amber sealed type also available A: Available Notes: 1. HC relays with ground terminals also available. 2. HC relays with 0.9 mm wide PC board terminals also available. HC RELAY CONTACT ARRANGEMENT Type Part number Features Single side stable contact HC� Suitable for high-capacity load switching Standard type HC relays have high single-contact capacity; 1 Form C: 10 A 2 Form C and 3 Form C: 7 A 4 Form C: 5 A 4-pole bifurcated (twin) contact HC4D Bifurcated (twin) contact ensures high contact reliability Suitable for low level loads Minimum switching capability: 100 μA 100m V DC (reference value) –2– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC LED INDICATION TYPE Type Part number Features With LED indication type HC�-HL LED lights up when relay is operating Inspection and detection of trouble is easy. LEDs are green for DC types and red for AC types. All types are available with LED indication. 1 2 3 4 5 6 7 8 9 10 11 12 13 – +14 LED • LED colors indicate the type of relay: red for AC type and green for DC type. Protection diode (Bottom view) HC RELAY SERIES PRODUCT TYPES Type Part number Features Amber sealed type HC relay HC�E HC relay with diode type (for DC) HC�-�-�V-D Has built-in diode to absorb surge when the coil goes to the off state (for Relay is completely sealed with resin. DC type). Provides high reliability in adverse surroundings. Suitable for protecting relay driver circuits and for noise suppression Suitable for use in dusty conditions or where organic gases are present Diode characteristics: Reverse breakdown voltage 1,000 V Forward current 1 A 4-pole bifurcated (twin) type and Relay with LED indication are available. TYPES 1. Standard type 1) Plug-in type Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1-H-AC6V-F HC1-H-AC12V-F HC1-H-AC24V-F HC1-H-AC48V-F HC1-H-AC100V-F HC1-H-AC120V-F HC1-H-AC200V-F HC1-H-AC240V-F HC1-H-DC6V-F HC1-H-DC12V-F HC1-H-DC24V-F HC1-H-DC48V-F HC1-H-DC100V-F 2 Form C Part No. HC2-H-AC6V-F HC2-H-AC12V-F HC2-H-AC24V-F HC2-H-AC48V-F HC2-H-AC100V-F HC2-H-AC120V-F HC2-H-AC200V-F HC2-H-AC240V-F HC2-H-DC6V-F HC2-H-DC12V-F HC2-H-DC24V-F HC2-H-DC48V-F HC2-H-DC100V-F 3 Form C Part No. HC3-H-AC6V-F HC3-H-AC12V-F HC3-H-AC24V-F HC3-H-AC48V-F HC3-H-AC100V-F HC3-H-AC120V-F HC3-H-AC200V-F HC3-H-AC240V-F HC3-H-DC6V-F HC3-H-DC12V-F HC3-H-DC24V-F HC3-H-DC48V-F HC3-H-DC100V-F 4 Form C Part No. HC4-H-AC6V HC4-H-AC12V HC4-H-AC24V HC4-H-AC48V HC4-H-AC100V HC4-H-AC120V HC4-H-AC200V HC4-H-AC240V HC4-H-DC6V HC4-H-DC12V HC4-H-DC24V HC4-H-DC48V HC4-H-DC100V 4 Form C (twin) Part No. HC4D-H-AC6V HC4D-H-AC12V HC4D-H-AC24V HC4D-H-AC48V HC4D-H-AC100V HC4D-H-AC120V HC4D-H-AC200V HC4D-H-AC240V HC4D-H-DC6V HC4D-H-DC12V HC4D-H-DC24V HC4D-H-DC48V HC4D-H-DC100V 2 Form C Part No. HC2-HL-AC6V-F HC2-HL-AC12V-F HC2-HL-AC24V-F HC2-HL-AC100V-F HC2-HL-AC120V-F HC2-HL-AC200V-F HC2-HL-AC240V-F HC2-HL-DC6V-F HC2-HL-DC12V-F HC2-HL-DC24V-F HC2-HL-DC48V-F HC2-HL-DC100V-F 3 Form C Part No. HC3-HL-AC6V-F HC3-HL-AC12V-F HC3-HL-AC24V-F HC3-HL-AC100V-F HC3-HL-AC120V-F HC3-HL-AC200V-F HC3-HL-AC240V-F HC3-HL-DC6V-F HC3-HL-DC12V-F HC3-HL-DC24V-F HC3-HL-DC48V-F HC3-HL-DC100V-F 4 Form C Part No. HC4-HL-AC6V HC4-HL-AC12V HC4-HL-AC24V HC4-HL-AC100V HC4-HL-AC120V HC4-HL-AC200V HC4-HL-AC240V HC4-HL-DC6V HC4-HL-DC12V HC4-HL-DC24V HC4-HL-DC48V HC4-HL-DC100V 4 Form C (twin) Part No. HC4D-HL-AC6V HC4D-HL-AC12V HC4D-HL-AC24V HC4D-HL-AC100V HC4D-HL-AC120V HC4D-HL-AC200V HC4D-HL-AC240V HC4D-HL-DC6V HC4D-HL-DC12V HC4D-HL-DC24V HC4D-HL-DC48V HC4D-HL-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. 2) Plug-in type (with LED indication) Nominal coil voltage 6V AC 12V AC 24V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1-HL-AC6V-F HC1-HL-AC12V-F HC1-HL-AC24V-F HC1-HL-AC100V-F HC1-HL-AC120V-F HC1-HL-AC200V-F HC1-HL-AC240V-F HC1-HL-DC6V-F HC1-HL-DC12V-F HC1-HL-DC24V-F HC1-HL-DC48V-F HC1-HL-DC100V-F Standard packing: Carton: 20 pcs.; Case: 200 pcs. –3– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC 3) PC board type Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1-HP-AC6V-F HC1-HP-AC12V-F HC1-HP-AC24V-F HC1-HP-AC48V-F HC1-HP-AC100V-F HC1-HP-AC120V-F HC1-HP-AC200V-F HC1-HP-AC240V-F HC1-HP-DC6V-F HC1-HP-DC12V-F HC1-HP-DC24V-F HC1-HP-DC48V-F HC1-HP-DC100V-F 2 Form C Part No. HC2-HP-AC6V-F HC2-HP-AC12V-F HC2-HP-AC24V-F HC2-HP-AC48V-F HC2-HP-AC100V-F HC2-HP-AC120V-F HC2-HP-AC200V-F HC2-HP-AC240V-F HC2-HP-DC6V-F HC2-HP-DC12V-F HC2-HP-DC24V-F HC2-HP-DC48V-F HC2-HP-DC100V-F 3 Form C Part No. HC3-HP-AC6V-F HC3-HP-AC12V-F HC3-HP-AC24V-F HC3-HP-AC48V-F HC3-HP-AC100V-F HC3-HP-AC120V-F HC3-HP-AC200V-F HC3-HP-AC240V-F HC3-HP-DC6V-F HC3-HP-DC12V-F HC3-HP-DC24V-F HC3-HP-DC48V-F HC3-HP-DC100V-F 4 Form C Part No. HC4-HP-AC6V HC4-HP-AC12V HC4-HP-AC24V HC4-HP-AC48V HC4-HP-AC100V HC4-HP-AC120V HC4-HP-AC200V HC4-HP-AC240V HC4-HP-DC6V HC4-HP-DC12V HC4-HP-DC24V HC4-HP-DC48V HC4-HP-DC100V 4 Form C (twin) Part No. HC4D-HP-AC6V HC4D-HP-AC12V HC4D-HP-AC24V HC4D-HP-AC48V HC4D-HP-AC100V HC4D-HP-AC120V HC4D-HP-AC200V HC4D-HP-AC240V HC4D-HP-DC6V HC4D-HP-DC12V HC4D-HP-DC24V HC4D-HP-DC48V HC4D-HP-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. Note: Please add “-31” before “-F” in the part number when ordering the PC board type 0.9 mm width terminal (ex) HC1-HP-AC6V-31-F. 4) PC board type (with LED indication) Nominal coil voltage 6V AC 12V AC 24V AC 100/110V AC 110/120V AC 200/220V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1-HPL-AC6V-F HC1-HPL-AC12V-F HC1-HPL-AC24V-F HC1-HPL-AC100V-F HC1-HPL-AC120V-F HC1-HPL-AC200V-F HC1-HPL-DC6V-F HC1-HPL-DC12V-F HC1-HPL-DC24V-F HC1-HPL-DC48V-F HC1-HPL-DC100V-F 2 Form C Part No. HC2-HPL-AC6V-F HC2-HPL-AC12V-F HC2-HPL-AC24V-F HC2-HPL-AC100V-F HC2-HPL-AC120V-F HC2-HPL-AC200V-F HC2-HPL-DC6V-F HC2-HPL-DC12V-F HC2-HPL-DC24V-F HC2-HPL-DC48V-F HC2-HPL-DC100V-F 3 Form C Part No. HC3-HPL-AC6V-F HC3-HPL-AC12V-F HC3-HPL-AC24V-F HC3-HPL-AC100V-F HC3-HPL-AC120V-F HC3-HPL-AC200V-F HC3-HPL-DC6V-F HC3-HPL-DC12V-F HC3-HPL-DC24V-F HC3-HPL-DC48V-F HC3-HPL-DC100V-F 4 Form C Part No. HC4-HPL-AC6V HC4-HPL-AC12V HC4-HPL-AC24V HC4-HPL-AC100V HC4-HPL-AC120V HC4-HPL-AC200V HC4-HPL-DC6V HC4-HPL-DC12V HC4-HPL-DC24V HC4-HPL-DC48V HC4-HPL-DC100V 4 Form C (twin) Part No. HC4D-HPL-AC6V HC4D-HPL-AC12V HC4D-HPL-AC24V HC4D-HPL-AC100V HC4D-HPL-AC120V HC4D-HPL-AC200V HC4D-HPL-DC6V HC4D-HPL-DC12V HC4D-HPL-DC24V HC4D-HPL-DC48V HC4D-HPL-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. Note: Please add “-31” before “-F” in the part number when ordering the PC board type 0.9 mm width terminal (ex) HC1-HPL-AC6V-31-F. 5) TM type Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1-HTM-AC6V-F HC1-HTM-AC12V-F HC1-HTM-AC24V-F HC1-HTM-AC48V-F HC1-HTM-AC100V-F HC1-HTM-AC120V-F HC1-HTM-AC200V-F HC1-HTM-DC6V-F HC1-HTM-DC12V-F HC1-HTM-DC24V-F HC1-HTM-DC48V-F HC1-HTM-DC100V-F 2 Form C Part No. HC2-HTM-AC6V-F HC2-HTM-AC12V-F HC2-HTM-AC24V-F HC2-HTM-AC48V-F HC2-HTM-AC100V-F HC2-HTM-AC120V-F HC2-HTM-AC200V-F HC2-HTM-DC6V-F HC2-HTM-DC12V-F HC2-HTM-DC24V-F HC2-HTM-DC48V-F HC2-HTM-DC100V-F 3 Form C Part No. HC3-HTM-AC6V-F HC3-HTM-AC12V-F HC3-HTM-AC24V-F HC3-HTM-AC48V-F HC3-HTM-AC100V-F HC3-HTM-AC120V-F HC3-HTM-AC200V-F HC3-HTM-DC6V-F HC3-HTM-DC12V-F HC3-HTM-DC24V-F HC3-HTM-DC48V-F HC3-HTM-DC100V-F 4 Form C Part No. HC4-HTM-AC6V HC4-HTM-AC12V HC4-HTM-AC24V HC4-HTM-AC48V HC4-HTM-AC100V HC4-HTM-AC120V HC4-HTM-AC200V HC4-HTM-DC6V HC4-HTM-DC12V HC4-HTM-DC24V HC4-HTM-DC48V HC4-HTM-DC100V 4 Form C (twin) Part No. HC4D-HTM-AC6V HC4D-HTM-AC12V HC4D-HTM-AC24V HC4D-HTM-AC48V HC4D-HTM-AC100V HC4D-HTM-AC120V HC4D-HTM-AC200V HC4D-HTM-DC6V HC4D-HTM-DC12V HC4D-HTM-DC24V HC4D-HTM-DC48V HC4D-HTM-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. –4– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC 2. Amber sealed type 1) Plug-in type Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1E-H-AC6V-F HC1E-H-AC12V-F HC1E-H-AC24V-F HC1E-H-AC48V-F HC1E-H-AC100V-F HC1E-H-AC120V-F HC1E-H-AC200V-F HC1E-H-AC240V-F HC1E-H-DC6V-F HC1E-H-DC12V-F HC1E-H-DC24V-F HC1E-H-DC48V-F HC1E-H-DC100V-F 2 Form C Part No. HC2E-H-AC6V-F HC2E-H-AC12V-F HC2E-H-AC24V-F HC2E-H-AC48V-F HC2E-H-AC100V-F HC2E-H-AC120V-F HC2E-H-AC200V-F HC2E-H-AC240V-F HC2E-H-DC6V-F HC2E-H-DC12V-F HC2E-H-DC24V-F HC2E-H-DC48V-F HC2E-H-DC100V-F 4 Form C Part No. HC4E-H-AC6V HC4E-H-AC12V HC4E-H-AC24V HC4E-H-AC48V HC4E-H-AC100V HC4E-H-AC120V HC4E-H-AC200V HC4E-H-AC240V HC4E-H-DC6V HC4E-H-DC12V HC4E-H-DC24V HC4E-H-DC48V HC4E-H-DC100V 4 Form C (twin) Part No. HC4ED-H-AC6V HC4ED-H-AC12V HC4ED-H-AC24V HC4ED-H-AC48V HC4ED-H-AC100V HC4ED-H-AC120V HC4ED-H-AC200V HC4ED-H-AC240V HC4ED-H-DC6V HC4ED-H-DC12V HC4ED-H-DC24V HC4ED-H-DC48V HC4ED-H-DC100V 2 Form C Part No. HC2E-L-AC6V-F HC2E-L-AC12V-F HC2E-L-AC24V-F HC2E-L-AC48V-F HC2E-L-AC100V-F HC2E-L-AC120V-F HC2E-L-AC200V-F HC2E-L-AC240V-F HC2E-L-DC6V-F HC2E-L-DC12V-F HC2E-L-DC24V-F HC2E-L-DC48V-F HC2E-L-DC100V-F 4 Form C Part No. HC4E-L-AC6V HC4E-L-AC12V HC4E-L-AC24V HC4E-L-AC48V HC4E-L-AC100V HC4E-L-AC120V HC4E-L-AC200V HC4E-L-AC240V HC4E-L-DC6V HC4E-L-DC12V HC4E-L-DC24V HC4E-L-DC48V HC4E-L-DC100V 4 Form C (twin) Part No. HC4ED-L-AC6V HC4ED-L-AC12V HC4ED-L-AC24V HC4ED-L-AC48V HC4ED-L-AC100V HC4ED-L-AC120V HC4ED-L-AC200V HC4ED-L-AC240V HC4ED-L-DC6V HC4ED-L-DC12V HC4ED-L-DC24V HC4ED-L-DC48V HC4ED-L-DC100V 2 Form C Part No. HC2E-HP-AC6V-F HC2E-HP-AC12V-F HC2E-HP-AC24V-F HC2E-HP-AC48V-F HC2E-HP-AC100V-F HC2E-HP-AC120V-F HC2E-HP-AC200V-F HC2E-HP-AC240V-F HC2E-HP-DC6V-F HC2E-HP-DC12V-F HC2E-HP-DC24V-F HC2E-HP-DC48V-F HC2E-HP-DC100V-F 4 Form C Part No. HC4E-HP-AC6V HC4E-HP-AC12V HC4E-HP-AC24V HC4E-HP-AC48V HC4E-HP-AC100V HC4E-HP-AC120V HC4E-HP-AC200V HC4E-HP-AC240V HC4E-HP-DC6V HC4E-HP-DC12V HC4E-HP-DC24V HC4E-HP-DC48V HC4E-HP-DC100V 4 Form C (twin) Part No. HC4ED-HP-AC6V HC4ED-HP-AC12V HC4ED-HP-AC24V HC4ED-HP-AC48V HC4ED-HP-AC100V HC4ED-HP-AC120V HC4ED-HP-AC200V HC4ED-HP-AC240V HC4ED-HP-DC6V HC4ED-HP-DC12V HC4ED-HP-DC24V HC4ED-HP-DC48V HC4ED-HP-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. 2) Plug-in type (With LED indication) Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1E-L-AC6V-F HC1E-L-AC12V-F HC1E-L-AC24V-F HC1E-L-AC48V-F HC1E-L-AC100V-F HC1E-L-AC120V-F HC1E-L-AC200V-F HC1E-L-AC240V-F HC1E-L-DC6V-F HC1E-L-DC12V-F HC1E-L-DC24V-F HC1E-L-DC48V-F HC1E-L-DC100V-F Standard packing: Carton: 20 pcs.; Case: 200 pcs. 3) PC board type Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1E-HP-AC6V-F HC1E-HP-AC12V-F HC1E-HP-AC24V-F HC1E-HP-AC48V-F HC1E-HP-AC100V-F HC1E-HP-AC120V-F HC1E-HP-AC200V-F HC1E-HP-AC240V-F HC1E-HP-DC6V-F HC1E-HP-DC12V-F HC1E-HP-DC24V-F HC1E-HP-DC48V-F HC1E-HP-DC100V-F Standard packing: Carton: 20 pcs.; Case: 200 pcs. Note: Please add “-31” in the suffix of part number when ordering the PC board type 0.9 mm width terminal. (4 Form C, 4 Form C (twin) only) –5– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC 4) PC board type (With LED indication) Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1E-PL-AC6V-F HC1E-PL-AC12V-F HC1E-PL-AC24V-F HC1E-PL-AC48V-F HC1E-PL-AC100V-F HC1E-PL-AC120V-F HC1E-PL-AC200V-F HC1E-PL-AC240V-F HC1E-PL-DC6V-F HC1E-PL-DC12V-F HC1E-PL-DC24V-F HC1E-PL-DC48V-F HC1E-PL-DC100V-F 2 Form C Part No. HC2E-PL-AC6V-F HC2E-PL-AC12V-F HC2E-PL-AC24V-F HC2E-PL-AC48V-F HC2E-PL-AC100V-F HC2E-PL-AC120V-F HC2E-PL-AC200V-F HC2E-PL-AC240V-F HC2E-PL-DC6V-F HC2E-PL-DC12V-F HC2E-PL-DC24V-F HC2E-PL-DC48V-F HC2E-PL-DC100V-F 4 Form C Part No. HC4E-PL-AC6V HC4E-PL-AC12V HC4E-PL-AC24V HC4E-PL-AC48V HC4E-PL-AC100V HC4E-PL-AC120V HC4E-PL-AC200V HC4E-PL-AC240V HC4E-PL-DC6V HC4E-PL-DC12V HC4E-PL-DC24V HC4E-PL-DC48V HC4E-PL-DC100V 4 Form C (twin) Part No. HC4ED-PL-AC6V HC4ED-PL-AC12V HC4ED-PL-AC24V HC4ED-PL-AC48V HC4ED-PL-AC100V HC4ED-PL-AC120V HC4ED-PL-AC200V HC4ED-PL-AC240V HC4ED-PL-DC6V HC4ED-PL-DC12V HC4ED-PL-DC24V HC4ED-PL-DC48V HC4ED-PL-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. Note: Please add “-31” in the suffix of part number when ordering the PC board type 0.9 mm width terminal. (4 Form C, 4 Form C (twin) only) 5) TM type Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1E-HTM-AC6V-F HC1E-HTM-AC12V-F HC1E-HTM-AC24V-F HC1E-HTM-AC48V-F HC1E-HTM-AC100V-F HC1E-HTM-AC120V-F HC1E-HTM-AC200V-F HC1E-HTM-AC240V-F HC1E-HTM-DC6V-F HC1E-HTM-DC12V-F HC1E-HTM-DC24V-F HC1E-HTM-DC48V-F HC1E-HTM-DC100V-F 2 Form C Part No. HC2E-HTM-AC6V-F HC2E-HTM-AC12V-F HC2E-HTM-AC24V-F HC2E-HTM-AC48V-F HC2E-HTM-AC100V-F HC2E-HTM-AC120V-F HC2E-HTM-AC200V-F HC2E-HTM-AC240V-F HC2E-HTM-DC6V-F HC2E-HTM-DC12V-F HC2E-HTM-DC24V-F HC2E-HTM-DC48V-F HC2E-HTM-DC100V-F 4 Form C Part No. HC4E-HTM-AC6V HC4E-HTM-AC12V HC4E-HTM-AC24V HC4E-HTM-AC48V HC4E-HTM-AC100V HC4E-HTM-AC120V HC4E-HTM-AC200V HC4E-HTM-AC240V HC4E-HTM-DC6V HC4E-HTM-DC12V HC4E-HTM-DC24V HC4E-HTM-DC48V HC4E-HTM-DC100V 4 Form C (twin) Part No. HC4ED-HTM-AC6V HC4ED-HTM-AC12V HC4ED-HTM-AC24V HC4ED-HTM-AC48V HC4ED-HTM-AC100V HC4ED-HTM-AC120V HC4ED-HTM-AC200V HC4ED-HTM-AC240V HC4ED-HTM-DC6V HC4ED-HTM-DC12V HC4ED-HTM-DC24V HC4ED-HTM-DC48V HC4ED-HTM-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. 4. With diode type (For DC) 1) Plug-in type Nominal coil voltage 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1-DC6V-D-F HC1-DC12V-D-F HC1-DC24V-D-F HC1-DC48V-D-F HC1-DC100V-D-F 2 Form C Part No. HC2-DC6V-D-F HC2-DC12V-D-F HC2-DC24V-D-F HC2-DC48V-D-F HC2-DC100V-D-F 3 Form C Part No. HC3-DC6V-D-F HC3-DC12V-D-F HC3-DC24V-D-F HC3-DC48V-D-F HC3-DC100V-D-F 4 Form C Part No. HC4-DC6V-D HC4-DC12V-D HC4-DC24V-D HC4-DC48V-D HC4-DC100V-D 4 Form C (twin) Part No. HC4D-DC6V-D HC4D-DC12V-D HC4D-DC24V-D HC4D-DC48V-D HC4D-DC100V-D 2 Form C Part No. HC2-L-DC6V-D-F HC2-L-DC12V-D-F HC2-L-DC24V-D-F HC2-L-DC48V-D-F HC2-L-DC100V-D-F 3 Form C Part No. HC3-L-DC6V-D-F HC3-L-DC12V-D-F HC3-L-DC24V-D-F HC3-L-DC48V-D-F HC3-L-DC100V-D-F 4 Form C Part No. HC4-L-DC6V-D HC4-L-DC12V-D HC4-L-DC24V-D HC4-L-DC48V-D HC4-L-DC100V-D 4 Form C (twin) Part No. HC4D-L-DC6V-D HC4D-L-DC12V-D HC4D-L-DC24V-D HC4D-L-DC48V-D HC4D-L-DC100V-D Standard packing: Carton: 20 pcs.; Case: 200 pcs. 2) Plug-in type (with LED indication) Nominal coil voltage 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HC1-L-DC6V-D-F HC1-L-DC12V-D-F HC1-L-DC24V-D-F HC1-L-DC48V-D-F HC1-L-DC100V-D-F Standard packing: Carton: 20 pcs.; Case: 200 pcs. * Sockets and mounting boards available –6– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC RATING 1. Standard type 1) Coil data (1) AC coils (50/60Hz) Type Nominal coil voltage Pick-up voltage* (at 20°C 68°F) Drop-out voltage* (at 20°C 68°F) 6V AC Standard 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 80%V or less of nominal voltage (Initial) 30%V or more of nominal voltage (Initial) Nominal coil current [±20%] (at 20°C 68°F) Coil inductance 50Hz 60Hz N.C. condition N.O. condition 224mA 200mA 0.078H 0.074H 111mA 56mA 28mA 13.4/14.7mA 12.2/13.5mA 6.7/7.4mA 100mA 50mA 25mA 12/13.2mA 10.9/11.9mA 6/6.6mA 0.312H 1.243H 4.974H 23.75H 27.19H 85.98H 0.295H 1.181H 4.145H 20.63H 25.57H 81.76H Nominal operating power 50Hz 60Hz 1.3VA 1.2VA Max. applied voltage (at 70°C 158°F) 110%V of nominal voltage * Square, pulse drive Notes: 1. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the rated voltage. In particular, for AC operation, if the applied voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will flow leading possibly to coil burnout. 2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation. (This value differs depending on the ambient temperature. Please contact us for details.) (2) DC coils Type Nominal coil voltage Pick-up voltage* (at 20°C 68°F) Drop-out voltage* (at 20°C 68°F) 80%V or less of nominal voltage (Initial) 10%V or more of nominal voltage (Initial) 6V DC Standard 12V DC 24V DC 48V DC 100/110V DC Nominal coil current [±10%] (at 20°C 68°F) 150mA Coil resistance [±10%] (at 20°C 68°F) 40Ω 75mA 37mA 18.5mA 10/11mA 160Ω 650Ω 2,600Ω 10,000Ω Nominal operating power Max. applied voltage (at 70°C 158°F) 0.9W 110%V of nominal voltage 1.0W * Square, pulse drive Notes: 1. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature. 2. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the rated voltage. 3. For use with 200 V DC, connect a 10 KΩ (5W) resistor, in series, to the 100 V DC relay. 4. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation. (This value differs depending on the ambient temperature. Please contact us for details.) –7– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC 2) Specifications Characteristics Contact Rating Electrical characteristics Item Arrangement Contact resistance (Initial) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current*4 Min. switching capacity (Reference value)*1 Insulation resistance (Initial) Breakdown voltage (Initial) 10A 250V AC 7A 250V AC 7A 250V AC 5A 250V AC 3A 250V AC 2,500VA 1,750VA 1,750VA 1,250VA 750VA 7A 250VAC 7A 5A 3A 10A 1mA 1V DC Between open contacts Between contact sets Between contact and coil 700 Vrms for 1min. (Detection current: 10mA.) 700 Vrms for 1min. (Detection current: 10mA.) 2,000 Vrms for 1min. (Detection current: 10mA.) Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Shock resistance Functional Destructive Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) Vibration resistance Functional Destructive 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 2 mm Min. 5×107: AC coil type (at 180 times/min.); Min. 108: DC coil type (at 180 times/min.) Min. 2×105 Min. 2×105 Min. 105 Min. 2×105 Min. 2×105 resistive load resistive load resistive load resistive load resistive load (at 20 times/min.) (at 20 times/min.) (at 20 times/min.) (at 20 times/min.) (at 20 times/min.) Ambient temperature: –50 to +70°C –58 to +158°F (without LED); –50 to +60°C –58 to +140°F (with LED) Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Approx. 30g 1.06 oz Mechanical Expected life Conditions 100μA 1V DC Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section. Operate time (initial, at 20°C 68°F)*2 Release time (initial, at 20°C 68°F)*2 Mechanical characteristics Specifications 2 Form C 3 Form C 4 Form C 4 Form C (twin) Max. 30 mΩ (By voltage drop 6 V DC 1A) Ag alloy (cd free) + Au flash AgNi type + Au clad 1 Form C Electrical Conditions for operation, transport and storage*3 Unit weight Notes: *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load. *2. For the AC coil types, the operate/release time will differ depending on the phase. *3. For the ambient temperature, refer to “NOTES”. *4. When using the socket and terminal socket, be sure to verify the max. continuous current. 3) Switching capacity and expected life (1) Electrical (at 20 times/min.) Load AC Resistive (cos ϕ = 1) Voltage 125V AC 10A 250V AC 10A 1 Form C 7A 5A 7A 5A 3A 7A — 5A 5A 3A 2A 3A 7A 5A 7A 5A 3A 7A — 5A 5A 3A 2A 3A 2 Form C 3 Form C 4 Form C 4 Form C (twin) DC Inductive (cos ϕ 0.4) 125V AC 250V AC 5A 3A 3A 2A 3.5A 2.5A 1.5A — 3.5A — 2A 1A 0.5A 1A 2.5A 1.5A 2A 1.5A 1A — 2A — 1A 0.8A 0.4A 0.8A Resistive 30V DC — Inductive 30V DC — Expected life 3A — — 3A — — — 3A — 3A — 3A 1A — — 0.6A — — — 0.4A — 0.4A — — Min. 5×105 Min. 106 Min. 2×105 Min. 5×105 Min. 106 Min. 105 Min. 2×105 Min. 5×105 Min. 2×105 Min. 5×105 Min. 106 Min. 2×105 Min. 2×105 (2) Mechanical (at 180 times/min.) AC coil type: Min. 5×107; DC coil type: Min. 108 –8– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC 2. Amber sealed type 1) Coil data Same coil data as HC relay standard type. Please refer to standard type information. 2) Specifications Characteristics Contact Item 1 Form C 1 Form C 5A 250V AC 1,250VA 250VAC 5A Arrangement Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Min. switching capacity (Reference value)*1 Rating Expected life 4 Form C (twin) 4 Form C 1A 250V AC 250VA 250VAC 1A 1mA 100mV DC 100μA 100mV DC Min. 2×105 resistive load (at 20 times/min.) Ambient temperature: –40°C to +60°C –40°F to +140°F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Electrical Conditions for operation, transport and storage*2 Conditions Specifications 2 Form C 4 Form C 2 Form C 4 Form C 3A 250V AC 2A 250V AC 700VA 500VA 250VAC 250VAC 3A 2A Notes: Other specifications are same as standard types. *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load. *2. For the ambient temperature, refer to “NOTES”. 3) Switching capacity and expected life (1) Electrical (at 20 times/min.) AC Load Voltage HC1E HC2E HC4E HC4ED (4 Form C twin) Resistive (cos ϕ = 1) 125V AC 250V AC 5A 5A 3A 3A 2A 2A 1A 1A DC Inductive (cos ϕ 0.4) 125V AC 250V AC — — — — — — — — Resistive 30V DC 3A 2A 2A — Inductive 30V DC 1A 0.7A 0.6A — Expected life Min. 2×105 Min. 2×105 Min. 2×105 Min. 2×105 (2) Mechanical (at 180 times/min.) AC coil type: Min. 5×107; DC coil type: Min. 108 3. With diode type (For DC) 1) Coil data Same coil data as HC relay standard type for DC. Please refer to standard type information. Please connect DC coil type built-in diode correctly by verifying the coil polarity. 2) Specifications Characteristics Conditions Item Conditions for operation, transport and storage* Specifications Ambient temperature: –50°C to +60°C –58°F to +140°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Notes: Other specifications are same as standard type HC relay. Please see the standard type HC relay. * For the ambient temperature, refer to “NOTES”. –9– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC REFERENCE DATA Standard type 2.-(1) Max. switching capacity (single contact type) Load: 250 V AC resistive load 10 5,000 Mechanical life (AC type) 500 400 1c 300 100 (250 V AC cosϕ = 1) 3 1c, 2c, 3c, 4c AC resistive load 0.4 2c 3 DC resistive load 0.4 4c 4 6 8 0.1 10 10 30 3.-(1) Coil temperature rise (1 Form C, AC type) Measured portion: Inside the coil Ambient temperature: 25°C 77°F 0.1 10 125 250 Contact voltage, V Load current, A 3.-(2) Coil temperature rise (2 Form C, AC type) (See note.) Measured portion: Inside the coil Ambient temperature: 30°C 86°F 100 90 90 80 10A 70 7A 5A 2A 0A 60 50 40 Temperature rise, °C 100 (See note.) 10A 80 5A 70 0A 60 50 40 80 50 40 20 10 10 0 0 80 90 100 110 0 120 0A 60 10 120 5A 70 30 110 7A 90 20 100 80 Coil applied voltage, %V Coil applied voltage, %V 90 100 Measured portion: Inside the coil Ambient temperature: 15 to 21°C 59 to 70°F (See note.) Measured portion: Inside the coil Ambient temperature: 29°C 84°F Measured portion: Inside the coil Ambient temperature: 29°C 84°F 120 5A 100 3A 80 1A 100 100 90 90 80 70 60 10A 5A 0A 50 40 60 40 30 20 20 20 10 10 0 0 100 110 120 80 90 100 110 120 Coil applied voltage, %V 3.-(7) Coil temperature rise (3 Form C, DC type) 3.-(8) Coil temperature rise (4 Form C, DC type) Measured portion: Inside the coil Ambient temperature: 29°C 84°F Measured portion: Inside the coil Ambient temperature: 17 to 18°C 62 to 64°F 100 90 90 80 7A 70 5A 60 0A 50 40 Temperature rise, °C 100 0 80 90 100 110 120 Coil applied voltage, %V Note: Coil temperature rise 80 When the nominal voltage is applied to 120 or 240 V AC coil types respectively, the figures of coil temperature rise increase by approx. 10 degrees to the ones shown on each graph. 5A 70 60 3A 1A 50 40 30 30 20 20 10 5A 0A 50 40 90 7A 70 30 80 120 80 60 Coil applied voltage, %V Temperature rise, °C Temperature rise, °C 140 Temperature rise, °C 3.-(6) Coil temperature rise (2 Form C, DC type) Temperature rise, °C 3.-(5) Coil temperature rise (1 Form C, DC type) 160 110 Coil applied voltage, %V 3.-(4) Coil temperature rise (4 Form C, AC type) 180 (See note.) 100 20 90 125 250 Contact voltage, V Measured portion: Inside the coil Ambient temperature: 18°C 64°F 30 80 30 3.-(3) Coil temperature rise (3 Form C, AC type) 30 0 AC resistive load 3c 2 Temperature rise, °C 4c DC resistive load Temperature rise, °C 200 1c 2c, 3c 7 5 Mechanical life (DC type) Contact current, A Life, ×104 times 10,000 2.-(2) Max. switching capacity [4-pole bifurcated (twin) contact type] Contact current, A 1. Life curve 10 80 90 100 110 120 Coil applied voltage, %V 0 80 90 100 110 120 Coil applied voltage, %V –10– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC Amber sealed type 1.-(1) Max. switching capacity (single contact type) 1.-(2) Max. switching capacity [4-pole bifurcated (twin) contact type] 2.-(1) Coil temperature rise (1 Form C AC type) Measured portion: Inside the coil Ambient temperature: 30°C 86°F 3 1c 1c, 2c, 3c, 4c AC resistive load 2c 2 1c 4c 2c, 4c 0.4 1 AC resistive load 0.4 Temperature rise, °C Contact current, A 5 Contact current, A 100 80 70 5A 60 50 40 30 20 DC resistive load DC resistive load 90 10 0.1 10 30 0.1 10 125 250 Contact voltage, V 30 0 125 250 Contact voltage, V 80 90 100 110 120 Voltage applied to coil, %V 2.-(3) Coil temperature rise (4 Form C AC type) 2.-(4) Coil temperature rise (1 Form C DC type) Measured portion: Inside the coil Ambient temperature: 30°C 86°F Measured portion: Inside the coil Ambient temperature: 30°C 86°F Measured portion: Inside the coil Ambient temperature: 30°C 86°F 100 100 90 90 80 70 3A 60 50 40 (See note.) 100 90 2A 80 70 60 50 40 80 70 60 50 30 30 20 20 20 10 10 10 0 0 80 90 100 110 120 Voltage applied to coil, %V 80 90 100 110 120 Voltage applied to coil, %V Note: Coil temperature rise Measured portion: Inside the coil Ambient temperature: 30°C 86°F When the nominal voltage is applied to 120 or 240 V AC coil types respectively, the figures of coil temperature rise increase by approx. 10 degrees to the ones shown on each graph. 100 90 5A 0A 40 30 2.-(5) Coil temperature rise (2 Form C DC type) Temperature rise, °C Temperature rise, °C (See note.) Temperature rise, °C Temperature rise, °C 2.-(2) Coil temperature rise (2 Form C AC type) 0 80 90 100 110 120 Voltage applied to coil, %V 80 70 60 5A 50 40 30 20 10 0 80 90 100 110 120 Voltage applied to coil, %V With diode type (For DC) 1.-(1) DC coil surge voltage waveform (without diode) 1.-(2) DC coil surge voltage waveform (with diode) Diode characteristics; Reverse breakdown voltage: 1,000V, Forward current: 1A ON OFF ON OFF 260V + + 12V DC – 12V DC To digital memory – To digital memory breakdown voltage: 1,000 V (Reverse ( Forward current: 1 A –11– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ Standard type 1) Plug-in type 1 Form C External dimensions CAD Data 20.8 .819 1.7 .067 1.7 .067 Schematic (Bottom view) Without LED indication type (AC/DC) 27.2 1.071 0.6 .024 2 35.2 1.386 2 7 12 13 14 14 LED AC type 6.4 .252 2 12 13 1 .039 2.54 .100 13.35 .526 4.45 4.41 .175 .174 7 LED DC type 2 7 0.5 .020 13 ( ) ∼ 4.06 .160 6.35 .250 6.35 .250 7 12 13 14 ( ) ∼ Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: 12 14 (+) (−) Tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 2 Form C External dimensions CAD Data 20.8 .819 1.7 .067 1.7 .067 Schematic (Bottom view) Without LED indication type (AC/DC) 27.2 1.071 0.6 .024 1 5 9 13 35.2 1.386 1 .039 1 4 5 8 9 12 13 14 14 LED AC type 6.4 .252 2.54 .100 4.41 13.35 .174 .526 4 8 12 1 5 9 13 ( ) 0.5 .020 ∼ 4.06 .160 6.35 .250 6.35 .250 LED DC type 4 8 12 1 5 9 13 14 ( ) ∼ Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: 4 8 12 14 (+) (−) Tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 3 Form C External dimensions CAD Data 20.8 .819 1.7 .067 1.7 .067 0.6 .024 Schematic (Bottom view) Without LED indication type (AC/DC) 27.2 1.071 2 3 5 6 7 8 9 13 14 9 6 14 LED AC type 6.4 .252 4 3 5 8 13 1 .039 1 2 4 7 35.2 1.386 2.54 .100 4.41 13.35 .174 .526 1 0.5 .020 1 2 3 1 2 3 4 5 8 6 4 9 7 5 8 9 7 13 ( ) 4.06 .160 6.35 .250 6.35 .250 ∼ 14 ( ) ∼ Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: –12– LED DC type 13 (−) 6 14 (+) Tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC 4 Form C and 4-pole bifurcated (twin) External dimensions CAD Data 20.8 .819 1.7 .067 1.7 .067 Schematic (Bottom view) Without LED indication type (AC/DC) 27.2 1.071 0.6 .024 35.2 1.386 1 2 3 4 5 6 7 8 9 10 11 12 13 0.5 .020 13 ( ) 4.06 .160 6.35 .250 6.35 .250 14 3 4 6 7 8 9 10 11 12 14 LED AC type 6.4 .252 4.45 .175 2 5 13 1 .039 2.54 .100 4.41 13.35 .174 .526 1 ∼ LED DC type 1 2 3 4 1 2 3 4 5 6 7 8 5 6 7 8 9 10 11 12 9 10 11 12 14 ( ) 13 ∼ Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: (−) 14 (+) Tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 2) PC board type 4 Form C External dimensions CAD Data 20.8 .819 1.7 .067 1.7 .067 The diagrams show the external dimensions of the 4 Form C and 4-pole bifurcated (twin) types. For 1 Form C, 2 Form C, and 3 Form C, see diagrams at plug-in types (only the terminals are different). Types with 0.9 mm .035 inch terminal width are also available. 27.2 1.071 0.6 .024 35.2 1.386 1 .039 1.5 .059 13.35 .526 4.45 .175 1.5 .059 0.5 .020 4.41 .174 1 2 3 4 5 6 7 8 9 10 11 13 3.5 .138 12 14 4.06 .160 6.35 .250 6.35 .250 Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: PC board pattern 1 Form C Schematic 2 Form C 10.4 .409 16.8 .661 8.9 .350 13.35 .526 5-2 dia. hole 5-.079 dia. 3 Form C 4.1 .161 4.1 .161 4.45 .175 Tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 8-2 dia. hole 8-.079 dia. 10.4 .409 16.8 .661 10.4 .409 16.8 .661 13.35 .526 Same schematic as plug-in type HC relay 4.1 .161 4.1 .161 10.4 .409 16.8 .661 13.35 .526 4 Form C 11-2 dia. hole 11-.079 dia. 4.45 .175 8.9 .350 13.35 .526 14-2 dia. hole 14-.079 dia. Tolerance: ±0.1 ±.004 –13– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC 3) TM type 4 Form C External dimensions CAD Data 20.6 .811 43 1.693 The diagrams show the external dimensions of the 4 Form C and 4-pole bifurcated (twin) types. For 1 Form C, 2 Form C, and 3 Form C, see diagrams at plug-in types (only the terminals are different). 2 .079 34.2 1.346 1 .039 3.6 .142 13.35 .526 4.45 .175 1 2 3 Schematic Same schematic as plug-in type HC relay Be aware that there is no LED indicator with built-in diode types. 4.31 .170 4 5 6 7 8 9 10 11 12 13 Chassis (Panel) cutout 6.4 .252 2.54 0.5 .100 .020 14 4.06 .160 37.6 6.35 27 1.480 .250 1.063 6.35 .250 Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: Tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 Chassis (Panel) cutout in tandem mounting 23 .906 2-3.6 dia. 2-.142 dia. 37.6 1.480 Tolerance: ±0.1 ±.004 37.6 1.480 21 .827 2 .079 21 .827 Notes: 1. In mounting, use M3 screws and M3 washers. 2. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover. 3. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm). Moreover, use washers to prevent loosening. –14– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC Amber sealed type 1) Plug-in type 1 Form C External dimensions CAD Data Schematic (Bottom view) Without LED indication type (AC/DC) 27.4 1.079 2 21.0 .827 7 12 Indication of DC coil indicates only with LED indication type 13 14 LED AC type 35.2 1.386 LED DC type 2 2 14 6.4 .252 0.5 .020 4.06 .160 4.51 .178 7 7 13 2.54 .100 12 (~) 14 (~) 13 12 (+) 14 (−) 13 6.35 .250 6.35 .250 (12) (14) (7) Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: 13.35 .526 (2) (13) 4.45 .175 Tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 2 Form C External dimensions CAD Data Schematic (Bottom view) Without LED indication type (AC/DC) 27.4 1.079 21.0 .827 Indication of DC coil indicates only with LED indication type 14 4.06 .160 4.51 .178 4 8 9 12 13 14 LED AC type 35.2 1.386 13 2.54 .100 6.4 .252 0.5 .020 1 5 LED DC type 1 5 4 8 1 5 4 8 9 (~) 13 12 (~) 14 9 (−) 13 12 (+) 14 6.35 .250 6.35 .250 (4) (8) (12) (14) (1) (5) (13) (9) Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: 13.35 .526 Tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 4 Form C and 4-pole bifurcated (twin) External dimensions CAD Data Schematic (Bottom view) Without LED indication type (AC/DC) 27.4 1.079 1 5 21.0 .827 2 6 3 7 4 8 9 10 11 12 Indication of DC coil indicates only with LED indication type 14 6.4 .252 4.06 .160 4.51 .178 14 LED AC type 35.2 1.386 0.5 .020 13 1 5 13 2.54 .100 2 6 3 7 LED DC type 1 5 4 8 2 6 3 7 4 8 9 10 11 12 (−) (+) 13 14 9 10 11 12 (~) (~) 13 14 6.35 .250 6.35 .250 (4) (8) (12) (14) (3) (7) (11) (2) (6) (10) (1) (5) (9) (13) Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: 13.35 .526 4.45 .175 –15– Tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC 2) PC board type 4 Form C and 4-pole bifurcated (twin) External dimensions CAD Data 27.4 1.079 21.0 .827 Indication of DC coil indicates only with LED indication type 35.2 1.386 Schematic 14 4.06 .160 4.51 .178 Same schematic as plug-in type HC relay 13 5 .197 0.5 .020 The diagrams show the external dimensions of the 4 Form C and 4-pole bifurcated (twin) types. For 1 Form C, 2 Form C, and 3 Form C, see diagrams at plug-in types (only the terminals are different). Types with 0.9 mm .035 inch terminal width are also available. 1.5 .059 3.5 .138 6.35 .250 6.35 .250 (4) (8) (12) (14) (3) (7) (11) (1) (5) (9) Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: 13.35 .526 (2) (6) (10) (13) 4.45 .175 Tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 PC board pattern 6.35 .250 6.35 .250 4.45 .175 4.06 .160 13.35 .526 14-2 dia. hole 14-.079 dia. hole Tolerance: ±0.1 ±.004 3) TM type 4 Form C and 4-pole bifurcated (twin) External dimensions CAD Data The diagrams show the external dimensions of the 4 Form C and 4-pole bifurcated (twin) types. For 1 Form C, 2 Form C, and 3 Form C, see diagrams at plug-in types (only the terminals are different). 2 .079 34.5 1.358 0.5 .020 43.0 1.693 37.6 1.480 27.6 1.087 4.06 .160 4.61 .181 4 8 12 3 7 11 2.54 .100 6.35 .250 6.35 .250 R1 R . .8 071 9 13 Schematic Same schematic as plug-in type HC relay Be aware that there is no LED indicator with built-in diode types. Chassis (Panel) cutout in tandem mounting 14 2 6 10 1 5 6.4 .252 13.35 21.0 .526 .827 23 .906 3.6 4.45 .142 .175 37.6 1.480 21 .827 2 .079 Chassis (Panel) cutout 21 .827 2-3.6 dia. 2-.142 dia. 37.6 1.480 Tolerance: ±0.1 ±.004 Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: Tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 Notes: 1. In mounting, use M3 screws and M3 washers. 2. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover. 3. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm). Moreover, use washers to prevent loosening. –16– ASCTB4E 201709-T To Be Discontinued Last time buy: September 30, 2018 HC With diode type (For DC) Same dimensions as HC relay standard/plug-in type Schematic CAD Data Without LED indicator With LED indicator 1 2 3 4 1 2 3 5 6 7 8 5 6 7 8 9 10 11 12 9 10 11 12 13− +14 13− 4 +14 LED Protection (surge-absorbing) diode Protection (surge-absorbing) diode SAFETY STANDARDS Item 1 Form C UL/C-UL (Recognized) File No. Contact rating E43028 10A 250V AC 1/3HP 125, 250V AC 3A 30V DC E43028 HC Standard 3 Form C 4 Form C 4 Form C twin 1 Form C 2 Form C E43028 4 Form C twin 1 Form C 2 Form C HC with diode type 3 Form C (For DC) 4 Form C 4 Form C twin LR26550 etc. 7A 250V AC / HP 125, 250V AC 3A 30V DC 5A 250V AC 1/10HP 125, 250V AC 3A 30V DC 3A 250V AC 3A 30V DC 6A 250V AC 1/6HP 125, 250V AC 3A 30V DC 4A 250V AC 1/10HP 125, 250V AC 3A 30V DC 2A 250V AC 1/20HP 125, 250V AC 2A 30V DC 1A 250V AC 1A 30V DC 10A 250V AC 1/3HP 125, 250V AC 3A 30V DC 7A 250V AC 1/6HP 125, 250V AC 3A 30V DC 7A 250V AC 1/6HP 125, 250V AC 3A 30V DC 5A 250V AC 1/10HP 125, 250V AC 3A 30V DC 3A 250V AC 3A 30V DC LR26550 etc. 16 E43028 E43149 E43028 E43028 HC Amber 4 Form C 7A 250V AC / HP 125, 250V AC 3A 30V DC 16 2 Form C E43028 E43149 E43028 E43028 E43028 E43028 E43149 File No. LR26550 etc. LR26550 etc. LR26550 etc. LR26550 etc. LR26550 etc. LR26550 etc. LR26550 etc. LR26550 etc. LR26550 etc. LR26550 etc. LR26550 etc. LR26550 etc. CSA (Certified) Contact rating 10A 250V AC 1/3HP 125, 250V AC 3A 30V DC 7A 250V AC / HP 125, 250V AC 3A 30V DC File No. 40017406 40017406 16 7A 250V AC / HP 125, 250V AC 3A 30V DC 5A 250V AC 1/10HP 125, 250V AC 3A 30V DC 3A 250V AC 3A 30V DC 6A 250V AC 1/6HP 125, 250V AC 3A 30V DC 4A 250V AC 1/10HP 125, 250V AC 3A 30V DC 2A 250V AC 1/20HP 125, 250V AC 2A 30V DC 1A 250V AC 1A 30V DC 10A 250V AC 1/3HP 125, 250V AC 3A 30V DC 7A 250V AC 1/6HP 125, 250V AC 3A 30V DC 7A 250V AC 1/6HP 125, 250V AC 3A 30V DC 5A 250V AC 1/10HP 125, 250V AC 3A 30V DC 3A 250V AC 3A 30V DC — 16 40017406 VDE (Certified) Contact rating 10A 250V AC (cosφ =1.0) 3A 250V AC (cosφ =0.4) 3A 30V DC (0ms) 7A 250V AC (cosφ =1.0) 2A 250V AC (cosφ =0.4) 3A 30V DC (0ms) — 5A 65V AC (cosφ =1.0) 3A 65V AC (cosφ =0.4) 3A 30V DC (0ms) TV rating (UL/CSA) File No. Rating UL TV-3 E43149 CSA LR26550 UL TV-3 E43149 CSA LR26550 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Remarks NOTES 1. For cautions for use, please read “General Application Guidelines”. 2. Diode characteristics 1) Reverse breakdown voltage: 1,000 V 2) Forward current: 1 A 3. Diode type Since the diode inside the relay coils are designed to absorb the counter emf, the element may be damaged if a large surge, etc., is applied to the diode. If there is the possibility of a large surge voltage from the outside, please implement measures to absorb it. –17– 4. Please connect DC coil types with LED and built-in diode correctly by verifying the coil polarity (“+” and “– ”). Connecting with reverse polarity will cause the LED not to light and damage the built-in diode due to its specification. ASCTB4E 201709-T
HC4D-HP-AC200V
物料型号:文档中列出了多种HC型继电器的型号,包括标准型、琥珀密封型、带二极管型(适用于直流)等。型号包括但不限于HC1-H-AC6V-F、HC2-H-AC6V-F、HC3-H-AC6V-F等,具体型号依据接触组态、端子类型、线圈电压等参数有所不同。

器件简介:HC型继电器适用于多种控制场合,包括工厂自动化设备、汽车设备、控制面板、电源设备等。它们提供标准型、琥珀密封型、带LED指示的型号,以及用于直流电路的带二极管型。

引脚分配:继电器的引脚分配根据型号有所不同,包括插件型、PCB板型和TM型。文档提供了详细的引脚分配图和说明。

参数特性:文档详细列出了继电器的电气特性,包括线圈电压、接触材料(如AgSnO2型和AgNi型)、接触电阻、绝缘电阻、击穿电压等。

功能详解:HC型继电器具有多种功能,如高负载切换能力、LED指示操作状态、防尘密封结构、以及用于直流电路的内置二极管,用于吸收反向电压,保护电路。

应用信息:继电器广泛应用于家庭电器、办公设备、自动售货机、电信设备、医疗设备等。

封装信息:文档提供了继电器的封装类型,包括插件型、PCB板型和TM型,以及它们的标准包装信息,如每箱数量。
HC4D-HP-AC200V 价格&库存

很抱歉,暂时无法提供与“HC4D-HP-AC200V”相匹配的价格&库存,您可以联系我们找货

免费人工找货