HE2AN-AC200V

HE2AN-AC200V

  • 厂商:

    NAIS(松下)

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
HE2AN-AC200V 数据手册
VDE TV-10/TV-15 rated 1a 30A 2a 20A power relays HE RELAYS FEATURES TYPICAL APPLICATIONS 1. Excellent resistance to contact welding Owing to the pre-tension and kick-off mechanism, the 1 Form A passes TV-15 and the 2 Form A passes TV-10. 2. High-capacity and long life 1. Office equipment Copiers, package air conditioners, automatic vending machines. 2. Industrial equipment Machine tools, molding equipment, wrapping machines, food processing equipment, etc. 3. Home appliances Air conditioners, microwave ovens, televisions, stereo systems, water heaters and air heating equipment. Contact arrangement Contact capacity Electrical life (at 20 times/min.) Mechanical life (at 180 times/ min.) 1 Form A Plug-in type HE 1 Form A type 2 Form A type 30A 20A 210 5 DC type: 107, AC type: 5106 3. Excellent surge resistance Between contacts and coil, the surge voltage is more than 10,000 V (when surge waveform accords with JEC-212-1981). 4. Compatible with all major safety standards UL, CSA, VDE and TÜV certified Form A type also available with 48A contact capacity Refer to data sheet, starting on page 9. Type Insulation gap Distance between contacts* Between open contacts Between contact and coil Breakdown voltage Single side stable type HE 1 Form A, 2 Form A Min. 8 mm 1 Form A and 2 Form A: PC board type: Min. 3 mm Min. 2.5 mm 2, 000 Vrms for 1 min. 5, 000 Vrms for 1 min. *Reference value CLASSIFICATION Type Operating funciton Contact arrangement PC board 1 Form A Plug-in 1 Form A 2 Form A TM Single side stable 1 Form A Screw terminal 2 Form A 1 Form A 2 Form A ORDERING INFORMATION HE HE Relay Contact arrangement 1a: 1 Form A (Single side stable type) 2a: 2 Form A (Single side stable type) Pick-up voltage N: 70% of nominal voltage Terminals Nil: Plug-in type S: Screw terminal type Q: TM type P: PC board type Coil voltage DC 6, 12, 24, 48, 100, 110 V AC 12, 24, 48, 100 (100/120), 200 (200/240) V ds_61C06_en_he: 150313D 1 HE TYPES 1. PC board type (1 Form A, DC coil) (Single side stable) 1 Form A Part No. HE1aN-P-DC6V HE1aN-P-DC12V HE1aN-P-DC24V HE1aN-P-DC48V HE1aN-P-DC100V HE1aN-P-DC110V Coil voltage 6V DC 12V DC 24V DC 48V DC 100V DC 110V DC Packing quantity Carton Case 25 pcs. 100 pcs. 2. Plug-in type (Single side stable) Type DC type AC type Coil voltage 6V DC 12V DC 24V DC 48V DC 100V DC 110V DC 12V AC 24V AC 48V AC 100/120V AC 200/240V AC 1 Form A Part No. HE1aN-DC6V HE1aN-DC12V HE1aN-DC24V HE1aN-DC48V HE1aN-DC100V HE1aN-DC110V HE1aN-AC12V HE1aN-AC24V HE1aN-AC48V HE1aN-AC100V HE1aN-AC200V 2 Form A Part No. HE2aN-DC6V HE2aN-DC12V HE2aN-DC24V HE2aN-DC48V HE2aN-DC100V HE2aN-DC110V HE2aN-AC12V HE2aN-AC24V HE2aN-AC48V HE2aN-AC100V HE2aN-AC200V 1 Form A Part No. HE1aN-Q-DC6V HE1aN-Q-DC12V HE1aN-Q-DC24V HE1aN-Q-DC48V HE1aN-Q-DC100V HE1aN-Q-DC110V HE1aN-Q-AC12V HE1aN-Q-AC24V HE1aN-Q-AC48V HE1aN-Q-AC100V HE1aN-Q-AC200V 2 Form A Part No. HE2aN-Q-DC6V HE2aN-Q-DC12V HE2aN-Q-DC24V HE2aN-Q-DC48V HE2aN-Q-DC100V HE2aN-Q-DC110V HE2aN-Q-AC12V HE2aN-Q-AC24V HE2aN-Q-AC48V HE2aN-Q-AC100V HE2aN-Q-AC200V Packing quantity Carton Case 20 pcs. 100 pcs. 20 pcs. 100 pcs. 3. TM type (Single side stable) Type DC type AC type 2 Coil voltage 6V DC 12V DC 24V DC 48V DC 100V DC 110V DC 12V AC 24V AC 48V AC 100/120V AC 200/240V AC Packing quantity Carton Case 20 pcs. 100 pcs. 20 pcs. 100 pcs. ds_61C06_en_he: 150313D HE 4. Screw terminal type (Single side stable) Type DC type AC type Coil voltage 6V DC 12V DC 24V DC 48V DC 100V DC 110V DC 12V AC 24V AC 48V AC 100/120V AC 200/240V AC 1 Form A Part No. HE1aN-S-DC6V HE1aN-S-DC12V HE1aN-S-DC24V HE1aN-S-DC48V HE1aN-S-DC100V HE1aN-S-DC110V HE1aN-S-AC12V HE1aN-S-AC24V HE1aN-S-AC48V HE1aN-S-AC100V HE1aN-S-AC200V 2 Form A Part No. HE2aN-S-DC6V HE2aN-S-DC12V HE2aN-S-DC24V HE2aN-S-DC48V HE2aN-S-DC100V HE2aN-S-DC110V HE2aN-S-AC12V HE2aN-S-AC24V HE2aN-S-AC48V HE2aN-S-AC100V HE2aN-S-AC200V Packing quantity Carton Case 10 pcs. 50 pcs. 10 pcs. 50 pcs. Note: The TM type of the screw terminals are also available. RATING 1. Coil data 1) AC coils Coil voltage Pick-up voltage (at 20C 68F) Drop-out voltage (at 20C 68F) 12V AC 24V AC 48V AC 100/120V AC 200/240V AC 70%V or less of nominal voltage (Initial) 15%V or more of nominal voltage (Initial) Pick-up voltage (at 20C 68F) Drop-out voltage (at 20C 68F) Nominal operating current [10%] (at 20C 68F) 138mA 74mA 39mA 18.7 to 2.1mA 9.1 to 10.8mA Nominal operating power Max. allowable voltage (at 20C 68F) 1.7VA 1.8VA 1.9VA 1.9 to 2.7VA 1.8 to 2.6VA 110%V of nominal voltage 2) DC coils Coil voltage 6V DC 12V DC 24V DC 48V DC 100V DC 110V DC 70%V or less of nominal voltage (Initial) ds_61C06_en_he: 150313D 10%V or more of nominal voltage (Initial) Nominal operating current [10%] (at 20C 68F) 320mA 160mA 80mA 40mA 19mA 18mA Coil resistance [10%] (at 20C 68F) Nominal operating power Max. allowable voltage (at 55C 131F) 18.8 75 300 1,200 5,200 6,300 1.92W 1.92W 1.92W 1.92W 1.92W 1.92W 110%V of nominal voltage 3 HE 2. Specifications Characteristics Contact Rating Item Arrangement Initial contact resistance, max Contact material Nominal switching capacity (resistive load) Max. switching power Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (Reference value)*1 Specifications 1 Form A 2 Form A Max. 100 m (By voltage drop 6 V DC 1A) AgSnO2 type 30A 277V AC 25A 277V AC 8,310VA 6,925VA 277V AC, 30V DC 30A 25A DC: 1.92W, AC: 1.7 to 2.7VA 100mA 5V DC Min. 1,000M (at 500V DC) Measurement at same location as “Initial breakdown voltage” section. 2,000 Vrms for 1min (Detection current: 10mA.) — 4,000 Vrms for 1min (Detection current: 10mA.) 5,000 Vrms for 1min (Detection current: 10mA.) Insulation resistance (Initial) Between open contacts Between contact sets Between contact and coil Surge breakdown voltage*2 (between contact and coil) Temperature rise Operate time (at nominal voltage) Breakdown voltage (Initial) Electrical characteristics Min. 10,000V (initial) DC: Max. 60C (at 55C) (By resistive method), AC: Max. 65C (at 55C) (By resistive method) Max. 30ms (excluding contact bounce time) DC: Max.10ms (excluding contact bounce time, without diode), AC: Max. 30ms (excluding contact bounce time) Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10s.) 10 to 55 Hz at double amplitude of 1.5 mm DC: Min. 107 (at 180 times/min.), AC: Min. 5106 (at 180 times/min.) Min. 105 (25A 277V AC) Min. 105 (30A 277V AC) Min. 2105 (30A 250V AC) Min. 2105 (20A 250V AC) Ambient temperature: –50C to +55C –58F to +131F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature), Air pressure: 86 to 106kPa 20 times/min. (at max. rating) PC board type: approx. 80g 2.82oz, Plug-in type/TM type: approx. 90g 3.17oz, Screw terminal type: approx. 120g 4.23oz Release time (at nominal voltage) Mechanical characteristics Expected life Conditions Functional Destructive Functional Vibration resistance Destructive Mechanical Shock resistance Electrical (resistive load) (at 20 times/min.) Conditions for operation, transport and storage*3 Conditions for operation, transport and storage*3 Unit weight *1 *2 *3 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. Wave is standard shock voltage of 1.250s according to JEC-212-1981 The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information. REFERENCE DATA 1 Form A Type 1. Maximum switching power 2. Life curve 3. Coil temperature rise (DC type) Measured portion: Inside the coil Contact current: 30 A 1,000 AC resistive 10 5 DC resistive 1 0.5 70 500 Temperature rise, °C 50 30 20 No. of operations, ×104 Contact current, A 100 100 250 V AC resistive 30 V DC resistive 50 10 60 20°C 50 40°C 40 60°C 30 20 5 10 30 100 500 1,000 Contact voltage, V 4 0 5 10 15 20 25 30 Contact current, A 35 0 100 110 120 Coil applied voltage, %V ds_61C06_en_he: 150313D HE 4. Ambient temperature characteristics Tested sample: HE1aN-AC120V, 6 pcs. Rate of change, % 30 -50 -20 20 Pick-up voltage x-x 10 Drop-out voltage 20 40 0 60 80 Ambient temperature, °C -10 -20 -30 2 Form A Type 1. Maximum switching power 2. Life curve 3. Coil temperature rise (DC type) Measured portion: Inside the coil Contact current: 30 A 1,000 AC resistive 10 DC resistive 5 70 500 60 Temperature rise, °C 50 30 20 No. of operations, ×104 Contact current, A 100 100 250 V AC resistive 30 V DC resistive 50 1 10 0.5 5 20°C 50 40°C 60°C 40 30 20 10 30 100 500 1,000 Contact voltage, V 0 5 10 15 20 25 30 Contact current, A 0 35 100 110 120 Coil applied voltage, %V 4. Ambient temperature characteristics Rate of change, % Tested sample: HE2aN-AC120V, 6 pcs. xx- Pick-up 20 voltage 10 Drop-out voltage -50 -20 0 20 40 60 80 Ambient temperature, °C -10 -20 -30 DIMENSIONS(mm inch) 1. PC board type 1 Form A CAD Data CAD Data Data from our Web site. Download CAD External dimensions Schematic (Bottom view) Single side stable type Single side stable type 33 1.299 38.0 1.496 1 4 PC board pattern (Bottom view) 4.7 .185 24 .945 8.4 .331 36.3 1.429 0.5 .020 4.7 .185 4 .157 General tolerance: 0.3 .012 ds_61C06_en_he: 150313D 6 18.6 .732 5 32 1.260 6-2 dia. hole 6-.079 dia. Tolerance: 0.1 .004 5 HE 2. Plug-in type 1 Form A CAD Data External dimensions Schematic (Bottom view) Single side stable type Single side stable type 36.4 1.433 2-4.5 dia. 2-.177 dia. 1 5 Panel cutout 2-4.5±0.1 dia. 2-.177±.004 dia. 40 1.575 50 1.969 #250 tab terminal 6.35 .250 6 R4 R.157 5 6 0.8 .031 4 4 33 1.299 8.4 10.25 .331 .404 1 40±0.1 1.575±.004 Tolerance: 0.1 .004 10.4 .409 35 1.378 3.5 .138 0.8 .031 General tolerance: 0.3 .012 2 Form A CAD Data External dimensions Schematic (Bottom view) Single side stable type Single side stable type 1 36.4 1.433 14.4 .567 2-4.5 dia. 2-.177 dia. 1 2 3 4 6.35 .250 4 5 Panel cutout R4 R.157 5 2-4.5±0.1 dia. 2-.177±.004 dia. 40 1.575 50 1.969 #250 tab terminal 8.4 10.25 .331 .404 0.8 .031 3 6 33 1.299 6 2 40±0.1 1.575±.004 Tolerance: 0.1 .004 10.4 .409 35 1.378 3.5 .138 0.8 .031 General tolerance: 0.3 .012 3. TM type External dimensions CAD Data Schematic (Bottom view) Single side stable type 1 Form A Single side stable type 2 Form A 47.6 1.874 36.4 1.433 14.4 .567 47.6 1.874 36.4 1.433 1 4 1 4.5 .177 33 1.299 2 3 8.4 10.25 .331 .404 0.8 .031 6.35 .250 R4 R.157 5 40 1.575 50 1.969 60 2.362 8.4 10.25 .331 .404 #250 tab terminal 10.4 .409 4 33 1.299 6 40 1.575 50 1.969 60 2.362 0.8 .031 6.35 .250 5 1 2 3 4 2 Form A 5 Panel cutout #250 tab terminal 2-4.5±0.1 dia. 2-.177±.004 dia. 47.6±0.1 1.874±.004 Tolerance: 0.1 .004 35 1.378 0.8 .031 6 6 10.4 .409 3.5 .138 4 1 Form A 4.5 .177 R4 R.157 5 6 1 3.5 .138 35 1.378 0.8 .031 General tolerance: 0.3 .012 6 ds_61C06_en_he: 150313D HE 4. Screw terminal type 1 Form A CAD Data External dimensions Schematic (Bottom view) Single side stable type Single side stable type M4.5 M.177 2-4.5 dia. 2-.177 dia. M3.5 M.138 51.0 2.008 40.0 1.575 14.4 .567 17.5 .689 21.5 .846 16.5 .650 R4 R.157 33.5 1.319 50.0 1.969 1 4 6 5 Panel cutout 2-4.5±0.1 dia. 2-.177±.004 dia. 40±0.1 1.575±.004 Tolerance: 0.1 .004 7.5 .295 44.5 1.752 3.5 .138 0.8 .031 General tolerance: 0.3 .012 2 Form A CAD Data External dimensions Schematic (Bottom view) Single side stable type Single side stable type M4.0 M.157 2-4.5 dia. 2-.177 dia. M3.5 M.138 1 51.0 2.008 40.0 1.575 36.4 1.433 14.4 .567 2 3 6 33.5 1.319 50.0 1.969 5 Panel cutout 17.5 .689 21.5 .846 16.5 .650 R4 R.157 4 2-4.5±0.1 dia. 2-.177±.004 dia. 40±0.1 1.575±.004 Tolerance: 0.1 .004 7.5 .295 44.5 1.752 3.5 .138 0.8 .031 General tolerance: 0.3 .012 MOUNTING METHOD 1. Plug-in type 2. Screw terminal type M4 screw M4 screw Washer Faston No. 250 ds_61C06_en_he: 150313D Washer 3. Allowable installation wiring size for screw terminal types and terminal sockets Due to the UP terminals, it is possible to either directly connect the wires or use crimped terminal. 7 HE SAFETY STANDARDS Item UL/C-UL (Recognized) File No. Contact rating CSA (Certified) File No. Contact rating File No. VDE (Certified) Contact rating TV rating (UL/CSA) File No. Rating E43028 30A 277V AC 30A 30V DC 1.5HP 125V AC 3HP 250V AC LR26550 30A 277V AC etc. 30A 30V DC 1.5HP 125V AC 3HP 250V AC 40006681 30A 250V AC (cos=1.0) 30A 250V AC (cos=0.4) 5A 110V DC (0ms) UL E43028 TV-15 E43028 25A 277V AC 25A 30V DC 1HP 125V AC 2HP 250V AC LR26550 25A 277V AC etc. 25A 30V DC 1HP 125V AC 2HP 250V AC 40006681 25A 250V AC (cos=1.0) 25A 250V AC (cos=0.4) 5A 110V DC (0ms) UL E43028 TV-10 1 Form A 2 Form A TÜV (Certified) File No. Rating B 09 04 30A 250V AC (cos=1.0) 13461 30A 250V AC (cos=0.4) 261 8A 110V DC (0ms) B 09 04 13461 261 25A 250V AC (cos=1.0) 25A 250V AC (cos=0.4) 8A 110V DC (0ms) NOTES 1. The dust cover should not be removed since doing so may alter the characteristics. 2. Avoid use under severe environmental conditions, such as high humidity, organic gas or in dust, oily locations and locations subjected to extremely frequent shock or vibrations. 3. When mounting, use spring washers. Optimum fastening torque ranges from 49 to 68.6 Nm (5 to 7 kgf·cm). 4. Firmly insert the receptacles so that there is no slack or looseness. To remove a receptacle, 19.6 to 39.2 N (2 to 4 kg) of pulling strength is required. Do not remove more than one receptacle at one time. Always remove one receptacle at a time and pull it straight outwards. 5. When using the AC type, the operate time due to the in-rush phase is 20 ms or more. Therefore, it is necessary for you to verify the characteristics for your actual circuit. 6. When using the push-on blocks for the screw terminal type, use crimped terminals and tighten the screw-down terminals to the torque below. M4.5 screw: 147 to 166.6 Ncm (15 to 17 kgf·cm) M4 screw: 117.6 to 137 N·cm (12 to 14 kgf·cm) M3.5 screw: 78.4 to 98 N·cm (8 to 10 kgf·cm) For Cautions for Use, see Relay Technical Information. 8 ds_61C06_en_he: 150313D HE VDE Ideal for solar inverter compact size, 1a 48A power relays HE RELAYS PV Type FEATURES • 48A current at 250 V AC achieved in compact size (L: 33  W: 38  H: 36.3 mm L: 1.299  W: 1.496  H: 1.429 inch) Due to improved conduction efficiency, wide terminal blades are used. (for high capacity type) • High insulation and 10,000 V surge breakdown voltage (between contacts and coil) achieved. • Conforms to various safety standards UL/C-UL and VDE TYPICAL APPLICATIONS • Photovoltaic power generation systems (Solar inverter) • Contact gap: 2.5 mm (VDE0126 compliant) Compliant with European photovoltaic standard VDE0126 Compliant with EN61810-1 2.5 kV surge breakdown voltage (between contacts) • Contributes to energy saving in devices thanks to reduced coil hold voltage Coil hold voltage can be reduced down to 40% of the nominal coil voltage (ambient temperature 20C 68F). This equals to operating power of approximately 310 mW. *Coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage. ORDERING INFORMATION HE 1a N P DC Contact arrangement 1a: 1 Form A (Single side stable type) Pick-up voltage N: 70% of nominal voltage Terminals P: PC board terminal type Coil voltage (DC) 6, 9, 12, 24V Type, contact material and switching capacity Y5: PV type, AgNi type (1 Form A 48A high capacity) Note: Certified by UL/C-UL and VDE ds_61C06_en_he: 280813D 9 HE TYPES High capacity type Part No. HE1aN-P-DC6V-Y5 HE1aN-P-DC9V-Y5 HE1aN-P-DC12V-Y5 HE1aN-P-DC24V-Y5 Nominal coi l voltage 6V DC 9V DC 12V DC 24V DC Standard packing: Carton: 20 pcs.; Case: 100 pcs. RATING 1. Coil data Nominal coil voltage Pick-up voltage (at 20C 68F) (Initial) Drop-out voltage (at 20C 68F) (Initial) 6V DC 9V DC 12V DC 24V DC 70%V or less of nominal voltage 10%V or more of nominal voltage Nominal operating current [10%] (at 20C 68F) 320mA 213mA 160mA 80mA Coil resistance [10%] (at 20C 68F) Nominal operating power Max. applied voltage (at 20C 68F) 1,920mW 110%V of nominal voltage 18.8 42.2 75.0 300.0 2. Specifications Characteristics Contact Rating Item Arrangement Contact resistance (Initial) Contact material Nominal switching capacity Contact carring power Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (Reference value)*1 Insulation resistance (Initial) Between open contacts Between contact and coil Surge breakdown voltage*2 (Between contact and coil) (Initial) Breakdown voltage (Initial) Electrical characteristics Temperature rise Coil hold voltage*3 Operate time (at 20C 68F) Release time (at 20C 68F)*5 Mechanical characteristics Shock resistance Functional Destructive Vibration resistance Functional Destructive Mechanical Expected life Conditions Resistive load Electrical Inductive load Conditions for operation, transport and storage*4 Max. operating speed Unit weight Specifications High capacity type 1 Form A Max. 100 m (By voltage drop 6 V DC 1A) AgNi type 48 A 250 V AC (Resistive load) 12,000 VA (Resistive load) 250 V AC 48 A (AC) 1,920 mW 100 mA 5 V DC Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section. 2,000 Vrms for 1 min. (Detection current: 10 mA) 5,000 Vrms for 1 min. (Detection current: 10 mA) 10,000 V Max. 60C 140F (By resistive method, contact carrying current: 48A, 100%V of nominal coil voltage at 55C 131F.) Max. 30C 86F (By resistive method, contact carrying current: 48A, 60%V of nominal coil voltage at 85C 185F.) 40 to 100%V (Contact carrying current: 48A, at 20C 68F), 50 to 100%V (Contact carrying current: 48A, at 55C 131F), 50 to 60%V (Contact carrying current: 48A, at 85C 185F) Max. 30 ms (nominal coil voltage, excluding contact bounce time) Max. 10 ms (nominal coil voltage, excluding contact bounce time) (without diode) Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10 s.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10 s.) 10 to 55 Hz at double amplitude of 1.5 mm Min. 106 (at 180 times/min.) Min. 3104 (48 A 250 V AC) (ON : OFF = 1s : 9s) Endurance: 48 A 250 V AC (cos = 0.8), Min. 3104 (ON : OFF = 0.1s : 10s) Overload: 72 A 250 V AC (cos = 0.8), Min. 50 (ON : OFF = 0.1s : 10s) Ambient temperature: –50 to +55C –58 to +131F (When nominal coil voltage applied) –50 to +85C –58 to +185F (When applied coil hold voltage is 50% to 60% of nominal coil voltage) Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature); Atmospheric pressure: 86 to 106 kPa 6 times/min. (at nominal switching capacity ON : OFF = 1s : 9s) Approx. 80 g 2.82 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of 1.250s according to JEC-212-1981 *3. Coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage. *4. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES (see page 12). *5. Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions. 10 ds_61C06_en_he: 280813D HE REFERENCE DATA 1. Coil temperature rise (High capacity type) Sample: HE1aN-P-DC9V-Y5, 6 pcs. Point measured: coil inside Ambient temperature: 25C 77F, 60C 140F, 85C 185F Contact carrying current: 48A Temperature rise, °C 70 60 25°C 50 60°C 40 85°C 30 20 10 0 50 60 70 80 90 100 Coil applied voltage, %V 2. Electrical life test (High capacity type, Resistive load 250V AC, 48A at 85C 185F) Sample: HE1aN-P-DC9V-Y5, 6 pcs. Change of pick-up and drop-out voltage Circuit: 250V AC 9V DC Contact welding detection and Miscontacting detection circuit Change of contact resistance 9 100 8 90 7 6 Pick-up voltage 5 Max. x Min. 4 3 Drop-out voltage 2 Max. x Min. 1 0 0 3 Contact resistance, mΩ Pick-up and drop-out voltage, V Operation frequency: 6 times/min. (ON/OFF = 1.0s : 9.0s) 80 70 60 50 40 30 20 Max. x Min. 10 0 0 3 No. of operations, x104 4 No. of operations, x10 DIMENSIONS (mm inch) CAD Data Data from our Web site. Download CAD High capacity type PC board pattern (Bottom view) External dimensions 38.0 1.496 33 1.299 6.5 .256 24 .945 8.4 .331 0.5 .020 6.3 .248 36.3 1.429 18.6 .732 1.3 .051 2-2 dia. hole 2-.079 dia. hole 4 .157 General tolerance: 0.3 .012 32 1.260 Tolerance: 0.1 .004 SAFETY STANDARDS Certification authority C-UL High capacity type VDE (VDE0435) Contact rating 48 A 277 V AC (at 85C 185F) *60A 277V AC (general use, at 60°C 140°F, 10k cycle), in use at 60% of rated coil voltage 48 A 250 V AC cos = 0.8 (at 85C 185F) *72A 250V AC (cosφ = 0.8 at 85°C 185°F, 50 cycle) *60A 250V AC (cosφ = 0.8 at 85°C 185°F, 10k cycle) *50A 20V DC (0ms, at 85°C 185°F, 30k cycle) * Under development. Please contact us. ** Only 9V DC type is certified by VDE. ds_61C06_en_he: 280813D 11 HE NOTES  Usage, transport and storage conditions 1) Temperature: –50 to +55C –58 to +131F –50 to +85C –58 to +185F (When applied coil hold voltage is 50% to 60% of nominal coil voltage) 2) Humidity: 5 to 85% RH (Avoid freezing and condensation.) The humidity range varies with the temperature. Use within the range indicated in the graph below. 3) Atmospheric pressure: 86 to 106 kPa Temperature and humidity range for usage, transport, and storage  Certification This relay is UL/C-UL certified. 48 A 277 V AC (High capacity type) This relay is certified by VDE 48 A 250 V AC cos = 0.8 (High capacity type) Humidity, %RH 85 Tolerance range (Avoid freezing when used at temperatures lower than 0°C 32°F) 5 –50 –58 (Avoid condensation when used at temperatures higher than 0°C 32°F) 0 +32 55 +131 Temperature, °C °F Humidity, %RH 85 Tolerance range (Avoid freezing when used at temperatures lower than 0°C 32°F) 5 –50 –58 (Avoid condensation when used at temperatures higher than 0°C 32°F) 0 +32 85 +185 Temperature, °C °F  –50 to +85C –58 to +185F (When applied coil hold voltage is 50% to 60% of nominal coil voltage) For Cautions for Use, see Relay Technical Information. 12 ds_61C06_en_he: 280813D HE ACCESSORIES (Terminal sockets) HE RELAY TERMINAL SOCKET FEATURES 1. Snap-in mounting to DIN rails is possible. Can be inserted into 35 mm wide DIN rails. Removal is easy, too. 2. Sure and easy wiring The use of UP terminals makes wiring exceptionally easy and sure. 3. Hold-down clips can be stored in main unit Because the hold-down clips can be stored in the main unit, there is no need to remove them when, for example, wiring is changed. TYPES No. of poles For 1 Form A For 2 Form A Types Single side stable type Single side stable type Part No. JH1-SF JH2-SF Standard packing: Carton: 10 pcs.; Case: 50 pcs. SPECIFICATIONS Item Specifications Arrangement Max. continuous current Breakdown voltage (initial) Insulation resistance Heat resistance 1 Form A 2 Form A 30A 250V AC 20A 250V AC 2,000 Vrms for 1min (between terminals) (Detection current: 10mA.) Min. 100M (between poles) 150C 3C for 1 hour Note: Do not insert or remove while powered on. DIMENSIONS (Unit: mm inch) 1 Form A and 2 Form A types External dimensions M3.5×4 screw M.138×4 7 4 3 7 Lot No. 4 5 5 9 .354 3 60 22 2.362 .866 2 1 6 6 7.2 .283 1 2 8 1 9.2 .362 8 9 .354 10.25 8.4 .404 .331 4 .157 Panel cutout M4×4 screw M.157×4 11 .433 14.4 .567 40 1.575 2-4.2 dia. hole (or 2-M4 screw hole) 2-.165 dia. hole (or 2-M.157 screw hole) 11 .433 16 .630 Relay mounting diagram 23 .906 34 1.339 70 2.756 61 2.402 Note: The JH1-SF (1 Form A single side stable type) does not have receptacles (tooth rests) for numbers 2, 3, 7, and 8. The JH2-SF (2 Form A single side stable type) does not have receptacles (tooth rests) for numbers 7 and 8. ds_61C06_en_he: 150313D 13 HE MOUNTING METHOD 1. Relay mounting 2. Installing to a DIN rail Push 3. Removing from a DIN rail Flat-head screwdriver NOTES 1. Be careful not to drop the relay. It is made of heat-hardened resin and may break. 2. Be sure to tighten the screw-down terminals firmly. Loose terminals may lead to the generation of heat. 3. When the 1 Form A is used in situations covered by the Japanese Electrical Appliance and Material Control Law, the use of 5.5 mm2 cabling and 30 A current is not allowed. Consequently, the circuit should be less than 20 A. 14 4. When fixing the terminal socket with screws, to avoid torque damage and distortion, apply torque within the ranges shown below. M3.5 screws: 0.784 to 0.98 N·m (8 to 10 kgf·cm) M4 screws: 1.176 to 1.37 N·m (12 to 14 kgf·cm) ds_61C06_en_he: 150313D
HE2AN-AC200V 价格&库存

很抱歉,暂时无法提供与“HE2AN-AC200V”相匹配的价格&库存,您可以联系我们找货

免费人工找货