HE2AN-DC110V 数据手册
HE VDE TV-10/TV-15 rated 1a 30A, 2a 20A power relays HE RELAYS FEATURES 4. Compatible with all major safety standards UL, CSA, VDE and TÜV certified 5. Terminals are available 1. Excellent resistance to contact welding Owing to the pre-tension and kick-off mechanism, the 1 Form A passes TV-15 and the 2 Form A passes TV-10. 2. High-capacity and long life Contact arrangement Contact capacity Electrical life (at 20 times/min.) Mechanical life (at 180 times/min.) 1 Form A Plug-in type Compliance with RoHS Directive TYPICAL APPLICATIONS 1 Form A type 2 Form A type 30A 1. Office equipment Copiers, package air conditioners, automatic vending machines. 2. Industrial equipment Machine tools, molding equipment, wrapping machines, food processing equipment, etc. 3. Home appliances Air conditioners, microwave ovens, televisions, stereo systems, water heaters and air heating equipment. 20A 2×105 DC type: 107, AC type: 5×106 3. Excellent surge resistance Between contacts and coil, the surge voltage is more than 10,000 V (when surge waveform accords with JEC-212-1981). Single side stable type HE 1 Form A, 2 Form A Min. 8 mm 1 Form A and 2 Form A: PC board type: Min. 3 mm Min. 2.5 mm Type Insulation gap Distance between contacts* Breakdown voltage Between open contacts Between contact and coil 2, 000 Vrms for 1 min. 5, 000 Vrms for 1 min. * Reference value CLASSIFICATION Type Operating funciton Contact arrangement PC board Plug-in 1 Form A 1 Form A 2 Form A TM Single side stable 1 Form A Screw terminal 2 Form A ORDERING INFORMATION HE HE Relay Contact arrangement 1a: 1 Form A (Single side stable type) 2a: 2 Form A (Single side stable type) Pick-up voltage N: 70% of nominal voltage Terminals Nil: Plug-in type S: Screw terminal type Q: TM type P: PC board type Nominal coil voltage DC 6, 12, 24, 48, 100, 110 V AC 12, 24, 48, 100 (100/120), 200 (200/240) V All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 1 Form A 2 Form A HE TYPES 1. PC board type (1 Form A, DC coil) (Single side stable) 1 Form A Part No. HE1aN-P-DC6V HE1aN-P-DC12V HE1aN-P-DC24V HE1aN-P-DC48V HE1aN-P-DC100V HE1aN-P-DC110V Nominal coil voltage 6V DC 12V DC 24V DC 48V DC 100V DC 110V DC Standard packing: Carton: 25 pcs.; Case: 100 pcs. 2. Plug-in type (Single side stable) Type DC type AC type Nominal coil voltage 1 Form A Part No. 2 Form A Part No. 6V DC 12V DC 24V DC 48V DC 100V DC 110V DC 12V AC 24V AC 48V AC 100/120V AC 200/240V AC HE1aN-DC6V HE1aN-DC12V HE1aN-DC24V HE1aN-DC48V HE1aN-DC100V HE1aN-DC110V HE1aN-AC12V HE1aN-AC24V HE1aN-AC48V HE1aN-AC100V HE1aN-AC200V HE2aN-DC6V HE2aN-DC12V HE2aN-DC24V HE2aN-DC48V HE2aN-DC100V HE2aN-DC110V HE2aN-AC12V HE2aN-AC24V HE2aN-AC48V HE2aN-AC100V HE2aN-AC200V 1 Form A Part No. HE1aN-Q-DC6V HE1aN-Q-DC12V HE1aN-Q-DC24V HE1aN-Q-DC48V HE1aN-Q-DC100V HE1aN-Q-DC110V HE1aN-Q-AC12V HE1aN-Q-AC24V HE1aN-Q-AC48V HE1aN-Q-AC100V HE1aN-Q-AC200V 2 Form A Part No. HE2aN-Q-DC6V HE2aN-Q-DC12V HE2aN-Q-DC24V HE2aN-Q-DC48V HE2aN-Q-DC100V HE2aN-Q-DC110V HE2aN-Q-AC12V HE2aN-Q-AC24V HE2aN-Q-AC48V HE2aN-Q-AC100V HE2aN-Q-AC200V 1 Form A Part No. HE1aN-S-DC6V HE1aN-S-DC12V HE1aN-S-DC24V HE1aN-S-DC48V HE1aN-S-DC100V HE1aN-S-DC110V HE1aN-S-AC12V HE1aN-S-AC24V HE1aN-S-AC48V HE1aN-S-AC100V HE1aN-S-AC200V 2 Form A Part No. HE2aN-S-DC6V HE2aN-S-DC12V HE2aN-S-DC24V HE2aN-S-DC48V HE2aN-S-DC100V HE2aN-S-DC110V HE2aN-S-AC12V HE2aN-S-AC24V HE2aN-S-AC48V HE2aN-S-AC100V HE2aN-S-AC200V Standard packing: Carton: 20 pcs.; Case: 100 pcs. 3. TM type (Single side stable) Type DC type AC type Nominal coil voltage 6V DC 12V DC 24V DC 48V DC 100V DC 110V DC 12V AC 24V AC 48V AC 100/120V AC 200/240V AC Standard packing: Carton: 20 pcs.; Case: 100 pcs. 4. Screw terminal type (Single side stable) Type DC type AC type Nominal coil voltage 6V DC 12V DC 24V DC 48V DC 100V DC 110V DC 12V AC 24V AC 48V AC 100/120V AC 200/240V AC Standard packing: Carton: 10 pcs.; Case: 50 pcs. Note: The TM type of the screw terminals are also available. * For terminal sockets, see page 223. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. HE RATING 1. Coil data 1) AC coils Nominal coil voltage Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) 70%V or less of nominal voltage (Initial) 15%V or more of nominal voltage (Initial) Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) Nominal operating current [±10%] (at 20°C 68°F) Nominal operating power 138mA 1.7VA 74mA 39mA 18.7 to 2.1mA 9.1 to 10.8mA 1.8VA 1.9VA 1.9 to 2.7VA 1.8 to 2.6VA 12V AC 24V AC 48V AC 100/120V AC 200/240V AC Max. applied voltage (at 20°C 68°F) 110%V of nominal voltage 2) DC coils Nominal operating current [±10%] (at 20°C 68°F) Coil resistance [±10%] (at 20°C 68°F) Nominal operating power 6V DC 320mA 18.8Ω 1.92W 12V DC 24V DC 48V DC 100V DC 110V DC 160mA 80mA 40mA 19mA 18mA 75Ω 300Ω 1,200Ω 5,200Ω 6,300Ω 1.92W 1.92W 1.92W 1.92W 1.92W Nominal coil voltage 70%V or less of nominal voltage (Initial) 10%V or more of nominal voltage (Initial) Max. applied voltage (at 55°C 131°F) 110%V of nominal voltage 2. Specifications Characteristics Contact Rating Item Contact material Arrangement Contact resistance (Initial) Nominal switching capacity (resistive load) Max. switching power Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (Reference value)*1 Insulation resistance (Initial) Specifications AgSnO2 type 1 Form A 2 Form A Max. 100 mΩ (By voltage drop 6 V DC 1A) 30A 277V AC 25A 277V AC 8,310VA 6,925VA 277V AC, 30V DC 30A 25A DC: 1.92W, AC: 1.7 to 2.7VA 100mA 5V DC Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section. Between open contacts Between contact sets Between contact and coil Temperature rise (coil) Surge breakdown voltage*2 (between contact and coil) (Initial) Operate time (at nominal voltage) 2,000 Vrms for 1min (Detection current: 10mA.) — 4,000 Vrms for 1min (Detection current: 10mA.) 5,000 Vrms for 1min (Detection current: 10mA.) DC: Max. 60°C (at 55°C) (By resistive method), AC: Max. 65°C (at 55°C) (By resistive method) Breakdown voltage (Initial) Electrical characteristics Release time (at nominal voltage) Functional Destructive Functional Vibration resistance Destructive Mechanical Shock resistance Mechanical characteristics Expected life Conditions Electrical (resistive load) (at 20 times/min.) Conditions for operation, transport and storage*3 Max. operating speed Unit weight Min. 10,000V Max. 30ms (excluding contact bounce time) DC: Max.10ms (excluding contact bounce time, without diode), AC: Max. 30ms (excluding contact bounce time) Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.) 10 to 55 Hz at double amplitude of 1.5 mm DC: Min. 107 (at 180 times/min.), AC: Min. 5×106 (at 180 times/min.) Min. 105 (25A 277V AC) Min. 105 (30A 277V AC) Min. 2×105 (30A 250V AC) Min. 2×105 (20A 250V AC) Ambient temperature: –50°C to +55°C –58°F to +131°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature), Air pressure: 86 to 106kPa 20 times/min. (at max. rating) PC board type: approx. 80g 2.82oz, Plug-in type/TM type: approx. 90g 3.17oz, Screw terminal type: approx. 120g 4.23oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. HE REFERENCE DATA 1 Form A Type 1. Maximum switching power 2. Life curve 3. Coil temperature rise (DC type) Measured portion: Inside the coil Contact current: 30 A 1,000 AC resistive 10 5 DC resistive 1 0.5 70 500 Temperature rise, °C 50 30 20 No. of operations, ×104 Contact current, A 100 100 250 V AC resistive 30 V DC resistive 50 10 60 20°C 50 40°C 40 60°C 30 20 5 10 30 100 500 1,000 0 5 10 Contact voltage, V 15 20 25 30 0 35 100 110 120 Coil applied voltage, %V Contact current, A 4. Ambient temperature characteristics Tested sample: HE1aN-AC120V, 6 pcs. Rate of change, % 30 –50 –20 20 Pick-up voltage x-x 10 Drop-out voltage 20 40 0 –10 60 80 Ambient temperature, °C –20 –30 2 Form A Type 1. Maximum switching power 2. Life curve 3. Coil temperature rise (DC type) 100 1,000 50 30 20 500 10 DC resistive 5 70 60 Temperature rise, °C AC resistive No. of operations, ×104 Contact current, A Measured portion: Inside the coil Contact current: 30 A 100 250 V AC resistive 30 V DC resistive 50 1 10 0.5 5 20°C 50 40°C 60°C 40 30 20 10 30 100 500 1,000 Contact voltage, V 0 5 10 15 20 25 30 Contact current, A 35 4. Ambient temperature characteristics Rate of change, % Tested sample: HE2aN-AC120V, 6 pcs. Pick-up 20 voltage xx- 10 Drop-out voltage –50 –20 0 20 40 –10 60 80 Ambient temperature, °C –20 –30 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 0 100 110 120 Coil applied voltage, %V HE DIMENSIONS (mm inch) 1. PC board type 1 Form A CAD Data The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac External dimensions Schematic (Bottom view) Single side stable type Single side stable type 33 1.299 38.0 1.496 1 4 6 5 PC board pattern (Bottom view) 24 .945 4.7 .185 8.4 .331 36.3 1.429 0.5 .020 4.7 .185 18.6 .732 4 .157 6-2 dia. hole 6-.079 dia. 32 1.260 General tolerance: ±0.3 ±.012 2. Plug-in type 1 Form A CAD Data Tolerance: ±0.1 ±.004 External dimensions Schematic (Bottom view) Single side stable type Single side stable type 36.4 1.433 2-4.5 dia. 2-.177 dia. 1 6.35 .250 6 5 R4 R.157 5 6 0.8 .031 4 4 33 1.299 8.4 10.25 .331 .404 1 Panel cutout 40 1.575 50 1.969 #250 tab terminal 2-4.5±0.1 dia. 2-.177±.004 dia. 40±0.1 1.575±.004 10.4 .409 Tolerance: ±0.1 ±.004 35 1.378 3.5 .138 0.8 .031 General tolerance: ±0.3 ±.012 2 Form A CAD Data External dimensions Schematic (Bottom view) Single side stable type Single side stable type 1 36.4 1.433 14.4 .567 2-4.5 dia. 2-.177 dia. 1 2 3 4 2 3 6 4 5 33 1.299 6 8.4 10.25 .331 .404 0.8 .031 6.35 .250 R4 R.157 5 Panel cutout 40 1.575 50 1.969 #250 tab terminal 2-4.5±0.1 dia. 2-.177±.004 dia. 10.4 .409 3.5 .138 35 1.378 0.8 .031 General tolerance: ±0.3 ±.012 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 40±0.1 1.575±.004 Tolerance: ±0.1 ±.004 HE 3. TM type Schematic (Bottom view) External dimensions CAD Data Single side stable type Single side stable type 1 Form A 2 Form A 47.6 1.874 36.4 1.433 14.4 .567 47.6 1.874 36.4 1.433 1 4.5 .177 33 1.299 40 1.575 50 1.969 60 2.362 8.4 10.25 .331 .404 6.35 .250 2 3 0.8 .031 3 4 5 Panel cutout 2-4.5±0.1 dia. 2-.177±.004 dia. 10.4 .409 35 1.378 2 6 #250 tab terminal 10.4 .409 5 2 Form A 40 1.575 50 1.969 60 2.362 6.35 .250 6 1 R4 R.157 5 8.4 10.25 .331 .404 #250 tab terminal 3.5 .138 4 33 1.299 6 4 1 Form A 4.5 .177 R4 R.157 5 6 0.8 .031 1 4 1 47.6±0.1 1.874±.004 Tolerance: ±0.1 ±.004 35 1.378 3.5 .138 0.8 .031 0.8 .031 General tolerance: ±0.3 ±.012 4. Screw terminal type 1 Form A CAD Data External dimensions Schematic (Bottom view) Single side stable type Single side stable type M4.5 M.177 2-4.5 dia. 2-.177 dia. M3.5 M.138 51.0 2.008 40.0 1.575 14.4 .567 R4 R.157 33.5 1.319 50.0 1.969 17.5 .689 21.5 .846 16.5 .650 1 4 6 5 Panel cutout 2-4.5±0.1 dia. 2-.177±.004 dia. 40±0.1 1.575±.004 7.5 .295 Tolerance: ±0.1 ±.004 44.5 1.752 3.5 .138 0.8 .031 General tolerance: ±0.3 ±.012 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. HE 2 Form A CAD Data External dimensions Schematic (Bottom view) Single side stable type Single side stable type M4.0 M.157 2-4.5 dia. 2-.177 dia. M3.5 M.138 1 51.0 2.008 40.0 1.575 36.4 1.433 14.4 .567 2 3 6 17.5 .689 21.5 .846 16.5 .650 R4 R.157 33.5 1.319 50.0 1.969 4 5 Panel cutout 2-4.5±0.1 dia. 2-.177±.004 dia. 7.5 .295 40±0.1 1.575±.004 Tolerance: ±0.1 ±.004 44.5 1.752 3.5 .138 0.8 .031 General tolerance: ±0.3 ±.012 MOUNTING METHOD 1. Plug-in type 2. Screw terminal type M4 screw M4 screw Washer 3. Allowable installation wiring size for screw terminal types and terminal sockets Due to the UP terminals, it is possible to either directly connect the wires or use crimped terminal. Washer Faston No. 250 SAFETY STANDARDS Item 1 Form A 2 Form A UL/C-UL (Recognized) File No. Contact rating E43028 30A 277V AC 30A 30V DC 1.5HP 125V AC 3HP 250V AC E43028 25A 277V AC 25A 30V DC 1HP 125V AC 2HP 250V AC CSA (Certified) File No. Contact rating LR26550 etc. 30A 277V AC 30A 30V DC 1.5HP 125V AC 3HP 250V AC 25A 277V AC 25A 30V DC 1HP 125V AC 2HP 250V AC LR26550 etc. File No. 40006681 40006681 VDE (Certified) Contact rating 30A 250V AC (cosφ =1.0) 30A 250V AC (cosφ =0.4) 5A 110V DC (0ms) 25A 250V AC (cosφ =1.0) 25A 250V AC (cosφ =0.4) 5A 110V DC (0ms) TV rating (UL/CSA) File No. Rating UL E43028 TV-15 UL E43028 TV-10 TÜV (Certified) Rating B 09 04 30A 250V AC (cosφ =1.0) 13461 261 30A 250V AC (cosφ =0.4) 8A 110V DC (0ms) File No. B 09 04 25A 250V AC (cosφ =1.0) 13461 261 25A 250V AC (cosφ =0.4) 8A 110V DC (0ms) NOTES 1. The dust cover should not be removed since doing so may alter the characteristics. 2. Avoid use under severe environmental conditions, such as high humidity, organic gas or in dust, oily locations and locations subjected to extremely frequent shock or vibrations. 3. When mounting, use spring washers. Optimum fastening torque ranges from 49 to 68.6 N⋅m (5 to 7 kgf·cm). 4. Firmly insert the receptacles so that there is no slack or looseness. To remove a receptacle, 19.6 to 39.2 N (2 to 4 kg) of pulling strength is required. Do not remove more than one receptacle at one time. Always remove one receptacle at a time and pull it straight outwards. 5. When using the AC type, the operate time due to the in-rush phase is 20 ms or more. Therefore, it is necessary for you to verify the characteristics for your actual circuit. 6. When using the push-on blocks for the screw terminal type, use crimped terminals and tighten the screw-down terminals to the torque below. M4.5 screw: 147 to 166.6 N⋅cm (15 to 17 kgf·cm) M4 screw: 117.6 to 137 N·cm (12 to 14 kgf·cm) M3.5 screw: 78.4 to 98 N·cm (8 to 10 kgf·cm) For Cautions for Use. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. HE RELAY ACCESSORIES HE RELAY TERMINAL SOCKET ACCESSORIES (Terminal sockets) FEATURES 1. Snap-in mounting to DIN rails is possible. Can be inserted into 35 mm wide DIN rails. Removal is easy, too. 2. Sure and easy wiring The use of UP terminals makes wiring exceptionally easy and sure. 3. Hold-down clips can be stored in main unit Because the hold-down clips can be stored in the main unit, there is no need to remove them when, for example, wiring is changed. TYPES No. of poles For 1 Form A For 2 Form A Types Part No. JH1-SF JH2-SF Single side stable type Standard packing: Carton: 10 pcs.; Case: 50 pcs. SPECIFICATIONS Item Arrangement Max. continuous current Breakdown voltage (initial) Insulation resistance Heat resistance Specifications 1 Form A 2 Form A 30A 250V AC 20A 250V AC 2,000 Vrms for 1min (between terminals) (Detection current: 10mA.) Min. 100MΩ (between poles) 150°C ±3°C for 1 hour Note: Do not insert or remove while powered on. DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac 1 Form A and 2 Form A types External dimensions CAD Data M4×4 screw M.157×4 M3.5×4 screw M.138×4 7 Lot No. 7 3 60 22 2.362 .866 2 1 6 6 7.2 .283 1 2 8 1 9.2 .362 8 9 .354 10.25 8.4 .404 .331 4 .157 40 1.575 4 4 3 5 5 9 .354 Panel cutout 11 .433 14.4 .567 2-4.2 dia. hole (or 2-M4 screw hole) 2-.165 dia. hole (or 2-M.157 screw hole) 11 .433 16 .630 Relay mounting diagram 23 .906 34 1.339 70 2.756 61 2.402 Note: The JH1-SF (1 Form A single side stable type) does not have receptacles (tooth rests) for numbers 2, 3, 7, and 8. The JH2-SF (2 Form A single side stable type) does not have receptacles (tooth rests) for numbers 7 and 8. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. HE RELAY ACCESSORIES MOUNTING METHOD 1. Relay mounting 2. Installing to a DIN rail 3. Removing from a DIN rail Push Flat-head screwdriver NOTES 1. Be careful not to drop the relay. It is made of heat-hardened resin and may break. 2. Be sure to tighten the screw-down terminals firmly. Loose terminals may lead to the generation of heat. 3. When the 1 Form A is used in situations covered by the Japanese Electrical Appliance and Material Control Law, the use of 5.5 mm2 cabling and 30 A current is not allowed. Consequently, the circuit should be less than 20 A. 4. When fixing the terminal socket with screws, to avoid torque damage and distortion, apply torque within the ranges shown below. M3.5 screws: 0.784 to 0.98 N·m (8 to 10 kgf·cm) M4 screws: 1.176 to 1.37 N·m (12 to 14 kgf·cm) All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HE2AN-DC110V 价格&库存

很抱歉,暂时无法提供与“HE2AN-DC110V”相匹配的价格&库存,您可以联系我们找货

免费人工找货
HE2AN-DC110V
  •  国内价格 香港价格
  • 1+447.664981+57.94557

库存:0