Micro Laser Distance Sensor [CMOS]
HG-C Series
ME-HGC1000 No.0059-28V
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
In Chinese
WARNING
●● This product is for the sensing (determination and measurement) of objects. Do
not use this product to secure safety, such as accident prevention which may affect human life and property.
●● Do not stare directly into the laser beam, or through observation optical equipment, such as lenses or etc. as it is dangerous.
1 INTENDED PRODUCTS FOR CE MARKING
●● This product complies with the following standards / regulations.
EMC Directive
CAN/CSA-C22.2 NO. 60947-5-2-14
2 CONFIRMATION OF PACKED CONTENTS
Sensor
1 pc.
Laser warning label (JIS Standards, GB Standard)
1 set each
FDA certification label
1 pc.
Instruction Manual (Japanese, English, Korean)
1 pc. each language
General Information for Safety, Compliance, and Instructions (23 languages) 1 pc.
4 PART DESCRIPTION
3 SAFE USE OF LASER PRODUCT
Zero set indicator (Yellow)
●● For the purpose of preventing any injury which may occur to the user by the use
of the laser product in advance, the following standards have been established by
the IEC Standards, JIS Standards, GB Standards and FDA Standards.
IEC : IEC 60825-1-2014
JIS : JIS C 6802-2014
GB : GB 7247.1-2012
FDA : PART 1040.10
Class*1
IIa
II
IIIa
IIIb
*2
*2
R
R*3,4
R
R
R
R
R*3,4
R
R
R
R
R*3,4
R
R
R
R
R*3,4
R
R
R
R*2
R*3,4
R
R
R
Performance (laser system)
Remote control connector [1040.10 (f) (3)]
Key control [1040.10 (f) (4)]
Emission indicator [1040.10 (f) (5)]
Beam attenuator [1040.10 (f) (6)]
Reset [1040.10 (f) (10)]
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
R
R
N/A
N/A
N/A
R
R
N/A
R
R
R*10
R
N/A
R
R
R*10
R
R*13
S
S
S
S
S
S
S
S
S
S*8
S
S
S*8
NP
S*11
S*8
NP
S*11
Labeling (all laser products)
Certification / identification [1010.2,3]
Protective housing [1040.10 (g) (6), (7)]
Aperture [1040.10 (g) (4)]
Class warning [1040.10 (g) (1), (2), (3)]
R
D*5
N/A
N/A
R
R*5
N/A
R*6
R
R*5
R
R*7
R
R*5
R
R*9
R
R*5
R
R*12
R
R*5
R
R*12
Information (all laser products)
User information [1040.10 (h) (1)]
Product literature [1040.10 (h) (2) (i)]
Service information [1040.10 (h) (2) (ii)]
R
N/A
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
*2
*2
R : Required
N/A : Not applicable
S : Same as for other products of that Class. Also see footnotes.
NP : Not permitted
D : Depends on level of interior radiation.
*3
*4
*5
*6
*7
*8
*9
*10
*11
*12
*13
DOWN key
5 MOUNTING
●● When mounting this product, use M3 screws (prepare separately).
Use a tightening torque of 0.5N・m for mounting.
●● When mounting this product using the sensor mounting bracket (optional), also
use a tightening torque of 0.5N・m.
IV
R
R*3,4
N/A
R
R
*2
UP key
: Class is based on the maximum level of laser exposure during operation.
: Required wherever and whenever human access to laser radiation above Class I limits is not
needed for products to perform its functions.
: Required for protective housings opened during operation or maintenance, if human access
thus gained is not always necessary when housing is opened.
: The requirements for interlock differ depending on the class of inner radiation.
: The contents of label differ depending on the level and wavelength of laser radiation inside
the protective housing.
: Warning statement label.
: CAUTION logotype.
: The method to measure the level of laser radiation to human body is required.
: CAUTION if 2.5mWcm-2 or less, DANGER is greater than 2.5mWcm-2
: Delay required between indication and emission.
: Exception should be provided for demonstration of laser products or light shows using laser
of Class IIIb or IV.
: DANGER logotype.
: Required after August 20, 1986.
M3 screws (prepare separately)
Mounting hole dimensions
37mm
I
Performance (all laser products)
Protective housing [1040.10 (f) (1)]
Safety interlocks [1040.10 (f) (2)]
Location of controls [1040.10 (f) (7)]
Viewing optics [1040.10 (f) (8)]
Scanning safeguards [1040.10 (f) (9)]
*1
*2
Digital indicator (Red)
Output operation indicator (Orange)
TEACH key
●● FDA Standards Outline
Performance (specific-purpose products)
Medical [1040.11 (a)]
Measurement, leveling, alignment [1040.11 (b)]
Demonstration [1040.11 (c)]
PRO indicator (Yellow)
Teaching indicator (Yellow)
Laser emission indicator (Green)
These standards classifies laser products according to the level of hazard and
provide the safety measures for respective classes.
Requirements
●● An English warning label is attached to this product. When this product is used
in Japan or China, peel off the English warning label, and attach the Japanese or
Chinese warning label.
●● When exporting this product to the United State of America attach the FDA certification label to the cable close to the sensing device.
18mm
Mounting Direction
●● Direction to a movable body
• When performing measurements
of moving objects with excessively different materials and
colors, mount the product per the
following directions to minimize
measurement errors.
• When measuring rotating objects,
mount the product as follows.
Measurement can be performed
with minimized effect on the object caused by up / down deflection, position deviation and etc.
• When there is a step in the moving object, mount the product as
follows. Measurement can be
performed with minimized effect
from the edges of the steps.
●● Measuring of narrow locations and recesses
• When measuring in narrow locations or inside holes, mount the
product so that optical path from
the light emitting part to lightreceiving part is not interrupted.
●● Mounting the sensor to a wall
• Mount the product as follows, so
that the multiple light reflections
on the wall do not emit to the lightreceiving part. When the reflection
factor on a wall is high, it is effective to use a dull black color.
1-point teaching (Window comparator mode)
●● This is mode is used for setting the threshold range for the distance from the reference value of the sensing object, by performing 1-point teaching. This mode is
used for sensing within the threshold range.
●● When performing 1-point teaching (window comparator mode), preset “Window
comparator mode 1” in the sensing output setting of the PRO mode. For the setting method, refer to “ 12 PRO MODE SETTING.”
6 I/O CIRCUIT DIAGRAMS
OFF
Threshold 2_SL
●● NPN Output Type
ON
(Brown) +V
Main circuit
(Pink) External input
Threshold 1_SL
Load
+
(Black) Control output
External
input
-
OFF
12 to 24V DC
±10%
(Blue) 0V
Sensing object
1. Press the TEACH key twice in the sensing object present condition.
(1st time: TEACH mode, 2nd time: Teaching)
(Gray) Analog output
Analog
input device
(Shield) Analog ground AGND
AGND
Reference surface
Automatic
●● PNP Output Type
2. Teaching is completed.
(Brown) +V
External
input
Main circuit
(Black) Control output
(Pink) External input
-
12 to 24V DC
±10%
Load
(Blue) 0V
(Gray) Analog output
Analog
input device
(Shield) Analog ground AGND
AGND
+
2-point teaching (Window comparator mode)
●● This is method to set the threshold range by conducting the 2-point teaching.
●● When performing 2-point teaching (window comparator mode), preset “Window
comparator mode 2” in the sensing output setting of the PRO mode.
For the setting, refer to “ 12 PRO MODE SETTING.”
●● When conducting teaching, use sensing objects (P-1 and P-2) whose distance are
different from each other.
7 TEACHING
Distance
OFF
2-point teaching
1st time (Threshold 1_SL)
OFF
●● This is the basic teaching method.
Sensing object P-1
2
Distance
1
2nd time (Threshold 2_SL)
ON
1. Press the TEACH key in the sensing object P-1 present condition. (1st time)
ON
Threshold
OFF
Background
Sensing object P-2
Sensing object
2. Press the TEACH key in the sensing object P-2 present condition. (2nd time)
1. Press the TEACH key in the background present condition.
Stable sensing is possible
2. Press the TEACH key in the sensing object present condition.
Stable sensing is not possible
Stable sensing is possible
3-point teaching (Window comparator mode)
Stable sensing is not possible
Limit-teaching
●● This is teaching method in case small object or object in background are existing.
●● This is the method to perform 3-point teaching (P-1, P-2, P-3) and to set the threshold range
by setting threshold 1_SL in the mid-point between the 1st time and 2nd time, and threshold
2_SL in the mid-point between the 2nd time and 3rd time as shown in the following figure.
●● When performing 3-point teaching (window comparator mode), preset “Window
comparator mode 3” in the sensing output setting of the PRO mode.
For the setting, refer to “ 12 PRO MODE SETTING.”
●● When performing teaching, use sensing objects (P-1, P-2, P-3) with different distance.
●● After teaching, P-1, P-2 and P-3 will be automatically rearranged from the smaller value.
Distance
UP key
Teaching value
ON
OFF
3rd time
Threshold 2_SL
2nd time
Threshold 1_SL
1st time
Sensing objectSensing object Sensing object
P-1
P-2
P-3
Background
Distance
OFF
Distance
Threshold
1. Press the TEACH key in the sensing object P-1 present condition. (1st time)
Teaching value
DOWN key
Threshold
2. Press the TEACH key in the sensing object P-2 present condition. (2nd time)
Sensing object
1. Press the TEACH key in the background present condition or the
sensing object present condition.
3. Press the TEACH key in the sensing object P-3 present condition. (3rd time)
2. When an object in the background is used as a reference, press the
UP key to set the threshold on the sensor side.
When a sensing object is used as a reference, press the DOWN
key to set the threshold on the sensing object side.
Stable sensing is possible
3. Teaching is completed.
Stable sensing is not possible
Automatic
Span adjustment in rising differential mode or trailing differential mode
10 ZERO SET FUNCTION
●● This mode is used to cancel the gradual changes in the measured value, and to
only detect sudden changes.
●● When performing rising differential mode or trailing differential mode, preset “Rising differential mode” or “Trailing differential mode” in the sensing output setting of
the PRO mode. For the setting method, refer to “ 12 PRO MODE SETTING.”
●● The threshold can be set by using the threshold value fine adjustment function.
For the threshold value fine adjustment function, refer to “ 8 THRESHOLD VALUE FINE ADJUSTMENT FUNCTION.”
●● The zero set function is the function to compulsorily set the measured value to “zero”.
●● The zero set indicator (yellow) will turn ON when the zero set is valid.
●● When the zero set function is executed while the peak / bottom hold function is
valid, the held measured value will be reset.
●● When the display setting is set to Offset, the zero set function cannot be set.
Press the UP key and DOWN key
simultaneously for 3 seconds.
Confirmed
1. Press the TEACH key.
2. Press the UP key or DOWN key to select the span.
Short span
Press the UP key and DOWN key
simultaneously for 6 seconds.
Long span
Automatic
“
“ will be displayed during this
period.
3. Press the TEACH key to set.
●● The setting or releasing of the zero set from an external input operates as in the following figure.
10ms or more
1 sec.
ON
8 THRESHOLD VALUE FINE ADJUSTMENT FUNCTION
OFF
●● Fine adjustment of the threshold can be performed in the measurement display.
●● Fine adjustment of the threshold can be performed even after teaching.
Press the UP / DOWN key
Press the UP / DOWN key
Press the TEACH key
Confirmed
Automatically
set after about 3
seconds.
Zero set release
Zero set valid period
●● When the power is turned ON again, zero set from external input can be released.
At this time, the zero set will not be saved.
●● Even when the zero set is set in the sensor, the zero set can be set or released
from an external input. However, when the power is turned ON again, the zero set
set in the sensor will be displayed.
11 KEY LOCK FUNCTION
●● The key lock function is to prevent acceptance of key operations, so that the conditions set in each setting mode are not changed accidentally.
●● When key operation is performed after the key lock is set, “
” will be displayed
on the digital display.
●● W hen the sensing output is set to window comparator mode, the display of
“
” and “
” can be changed by pressing the TEACH key for 1 second.
Press the TEACH
key for 1 second
Zero set setting
Change the threshold value
Press the TEACH key and DOWN
key simultaneously for 3 seconds.
Automatic
Measurement display
Automatic
Press the TEACH key and DOWN
key simultaneously for 3 seconds.
Automatic
●● When performing a fine adjustment of the threshold of “
” or
”, press
the UP key or DOWN key. After “
” or “
” is displayed, the fine adjustment of the threshold can be performed.
Press down UP /
DOWN key
Press down UP /
DOWN key
12 PRO MODE SETTING
Part description
Press the TEACH
key
DOWN key (Select)
TEACH key (Confirmed)
Automatic
Confirmed
or
(Automatically set after about 3 seconds.)
9 PEAK / BOTTOM HOLD FUNCTION
●● The peak / bottom hold function, is for displaying the peak value and bottom value.
●● When the zero set function is executed while the peak / bottom hold function is
set to “Peak hold” or “Bottom hold”, the held measured value will be reset.
Default setting
Response speed
setting
Output operation
setting
Sensing output
setting
Press the TEACH key
Select
Confirmed
Hysteresis setting
or
External input
setting
Digital Display
or
Automatically set after
about 3 seconds.
or
Description
Function
: Press UP key or DOWN key
: Press DOWN key
UP key (Select)
Analog output
setting
Press down UP /
DOWN key
: Press the TEACH key
●● The PRO indicator (yellow) will turn ON when the PRO mode is set.
●● When the DOWN key is pressed for 3 seconds or more in the middle of the PRO
MODE setting, the display returns to the measurement display.
Item
Press the TEACH key
and UP key simultaneously for 3 seconds.
Arrow description in figures
PRO indicator (Yellow)
Timer setting
Hold function
release
Releases the hold status,
and outputs the current
measured value
Display setting
Peak hold
Holds maximum measured value
Hold setting
Bottom hold
Holds minimum measured
value
ECO Setting
Reset setting
Description
Set the response time.
“
”: High precision 10ms, “
”: Standard 5ms
“
”: High speed 1.5ms
Select the control output operation mode.
“
”: Light-ON, “
”: Dark-ON
Set the sensing output.
“
”: Normal sensing mode
“
”: 1-point teaching (Window comparator mode)
“
”: 2-point teaching (Window comparator mode)
“
”: 3-point teaching (Window comparator mode)
“
”: Trailing differential mode
“
”: Trailing differential mode
Sets the output operation of analog output setting.
“
”: Analog voltage output (0 to +5V)
“
”: Analog current output (4 to 20mA)
Set the hysteresis width.
HG-C1030: 0.001 to 5.00mm
HG-C1050: 0.01 to 15.00mm
HG-C1100: 0.02 to 35.00mm
HG-C1200: 0.1 to 80.0mm
HG-C1400: 0.2 to 200.0mm
Set the external input.
“
”: Zero set function, “
”: Teaching function
“
”: Light emitting stop function, “
”: Trigger function
Set the timer operation. The timer time is fixed at 5ms.
“
”: No timer, “
”: OFF-delay timer
“
”: ON-delay timer, “
”: One-shot timer
The display of the measured value can be changed.
“
”: Normal, “
”: Invert, “
”: Offset
Set the control output and the analog output operation when a
measurement error occurs (insufficient light intensity, saturation of light intensity, out of measurement range).
“
”: Hold OFF, “
”: Hold ON
The digital display can be set to go OFF when key operation is not
performed for 30 seconds. Current consumption can be reduced.
“
”: ECO OFF, “
”: ECO ON
Return to the default setting (factory setting).
“
”: Reset NG, “
”: Reset OK
●● Do not use this product during the transient state when the power supply is turned ON.
●● The overall length of the cable can be extended to 10m maximum with a cable
size of 0.3mm2 or more.
●● Make sure that stress by forcible bend or pulling is not applied to the sensor cable joint.
●● Although it depends on the type, light from rapid start type or high frequency
lighting type fluorescent lights, sunlight and etc. may affect the sensing, therefore
make sure to prevent direct incident light.
●● This product is suitable for indoor use only.
●● Keep water, oil, fingerprints and etc. which reflect light, or dust, particles or etc. which interrupts the light, away from the emitting / receiving surfaces of this product. If contaminants adhere to the surface, wipe off with a dust-free soft cloth, or lens cleaning paper.
●● Do not use the sensor in locations where there is excessive vapor, dust or etc. or
in an atmosphere where corrosive gases, etc. is generated.
●● Take care that the product does not come in contact with oil, grease, organic solvents such as thinner, etc., strong acid or alkaline.
●● Make sure to turn OFF the power supply, before cleaning the light emitting / receiving windows of the sensor head.
●● There is a certain deviation in the directionality of this product. Install the product
using a mounting bracket or similar fitting to allow the adjustment of optical axis.
●● The internal memory (nonvolatile) of this product has a service life. Settings cannot be configured more than 100,000 times.
Procedure
Measurement display
DOWN: Press for 3 seconds
Response time
setting
High precision
TEACH
UP /
DOWN
Standard
UP /
DOWN
High speed
UP / DOWN
Output operation
setting
Light-ON
UP /
DOWN
TEACH
UP / DOWN
Sensing output
setting
Normal sensing
mode
TEACH
UP /
DOWN
Dark-ON
1-point teaching
Window comparator mode
UP /
DOWN
2-point teaching
Window comparator mode
14 ERROR INDICATION
●● In case of errors, attempt the following measures.
UP /
DOWN
UP /
DOWN
Error indication
UP /
DOWN
UP /
DOWN
Measured value blinks
UP / DOWN
Trailing differential mode
Analog output
setting
Analog voltage
output
TEACH
3-point teaching
Window comparator mode
Rising differential mode
UP /
DOWN
Description
Remedy
Insufficient amount of reflected light.
The sensing object is out of the sensing range.
Confirm that the sensing distance is within the
specification range.
Adjust the installation angle of the sensor.
Flash memory is damaged or passed its life expectancy.
Please contact our office.
Load of the sensing output is short-circuited
causing an over-current to flow.
Turn OFF the power and check the load.
The semiconductor laser is damaged or
passed its life expectancy.
Please contact our office.
• W
hen zero set is set, the measurement is
not performed normally.
• Since the display setting is set to “Offset”,
the zero set function can not be used.
• C
onfirm that the sensing distance is within
the specification range.
• Set the display to any setting except “Offset.”
During teaching, the measurement is not performed normally.
Confirm that the sensing distance is within the
specification range.
System error
Please contact our office.
Analog current
output
UP / DOWN
Hysteresis setting
Hysteresis width
TEACH
UP key
: Increases hysteresis width
DOWN key : Decreases hysteresis width
15 SPECIFICATIONS
UP / DOWN
External input
setting
Zero set function
TEACH
UP /
DOWN
Teaching function
UP /
DOWN
Light emitting
stop function
UP /
DOWN
Trigger function
UP / DOWN
Timer setting
No timer
TEACH
UP /
DOWN
OFF-delay
UP /
DOWN
ON-delay
UP /
DOWN
One-shot
Type
NPN output
Model No.
PNP output
Measurement center
distance
Measurement range
Repeatability
Linearity
UP / DOWN
Display setting
Normal
TEACH
UP /
DOWN
Invert
UP /
DOWN
Offset
Light source
Beam diameter (Note 3)
Supply voltage
Power consumption
UP / DOWN
Hold setting
Temperature characteristic
Hold OFF
TEACH
UP /
DOWN
Hold ON
Control output
UP / DOWN
ECO Setting
ECO OFF
TEACH
UP /
DOWN
ECO ON
UP / DOWN
Reset setting
Reset NG
TEACH
UP /
DOWN
Output operation
Short-circuit protection
Analog voltage
output
Analog output
Analog current
output
Response time
Reset OK
UP / DOWN
Response time
setting
13 CAUTIONS
●● This product has been developed / produced for industrial use only.
●● Make sure that the power supply is OFF before starting the wiring.
●● If the wiring is performed incorrectly, it will cause a failure.
●● Do not run the wires together with high-voltage lines or power lines, or put them in
the same raceway. This can cause malfunction due to induction.
●● Verify that the supply voltage variation is within the rating.
●● If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
●● If noise generating devices (switching regulators, inverter motors, etc.) are used
around the sensor mounting area, make sure to connect the frame ground (FG)
terminal of the device.
External input
Protection
Degree of pollution
Ambient temperature
Ambient humidity
Ambient illuminance
Operating altitude
Cable
Material
Weight
Measurement
center 30mm type
HG-C1030
HG-C1030-P
Measurement
center 50mm type
HG-C1050
HG-C1050-P
Measurement center 100mm type
HG-C1100
HG-C1100-P
Measurement center 200mm type
HG-C1200
HG-C1200-P
30mm
50mm
100mm
200mm
400mm
±5mm
±15mm
±35mm
±80mm
10μm
30μm
70μm
200μm
±200mm
300μm (measurement
distance 200 to 400mm)
800μm (measurement
distance 400 to 600mm)
±0.2%F.S. (measurement
distance 200 to 400mm)
±0.3%F.S. (measurement
distance 400 to 600mm)
±0.1%F.S.
±0.2%F.S.
Measurement center 400mm type
HG-C1400
HG-C1400-P
0.03%F.S./°C
Red semiconductor laser Class 2 [JIS / IEC / GB / FDA (Note 2)]
Max. output: 1mW, Emission peak wavelength: 655nm
Approx.
Approx.
Approx.
Approx.
Approx.
ø50μm
ø70μm
ø120μm
ø300μm
ø500μm
12 to 24V DC ±10%, Ripple P-P 10% or less
40mA or less (at 24V DC supply voltage), 65mA or less (at 12V DC supply voltage)
NPN open-collector transistor
PNP open-collector transistor
• Maximum sink current: 50mA
• Maximum source current: 50mA
• Applied voltage: 30V DC or less
• Applied voltage: 30V DC or less
(Between control output to 0V)
(Between control output to +V)
• Residual voltage: 1.5V or less
• Residual voltage: 1.5V or less
(At 50mA sink current)
(At 50mA source current)
• Leakage current: 0.1 mA or less
• Leakage current: 0.1 mA or less
Switchable either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to +5V (at alarm: +5.2V)
• Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA)
• Load impedance: 300Ω or less
Switchable between 1.5ms / 5ms / 10ms
NPN non-contact input
PNP non-contact input
• Input conditions
• Input conditions
Invalid: +8 to +V DC or Open
Invalid: 0 to +0.6V DC or Open
Valid: 0 to +1.2V DC
Valid: +4 to +V DC
• Input impedance: Approx. 10kΩ
• Input impedance: Approx. 10kΩ
IP67 (IEC)
2
-10 to +45°C (No dew condensation or icing allowed), Storage: -20 to +60°C
35 to 85% RH, Storage: 35 to 85% RH
Incandescent lamp: Acceptance surface illuminance 3,000ℓx or less
2,000m or less
0.2mm2 5-core composite cable, 2m long
Enclosure: Aluminum die-cast, Front cover: Acrylic
Approx. 35g (without cable), approx. 85g (including cable)
Notes: 1) Supply voltage: 24V DC, ambient temperature: +20°C, response time: 10ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics.
2) This is based on the FDA Standard, according to Laser Notice No. 50 of the FDA Standard.
3)
This is the size in the measurement center distance. These values were defined by using 1/e2 (approx. 13.5%)
of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting
point may be higher than at the point and this may affect the measurement value.