HG-C1200

HG-C1200

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SENSOR REFLECTIVE 200MM NPN OPEN

  • 数据手册
  • 价格&库存
HG-C1200 数据手册
●● WARNING label INSTRUCTION MANUAL ●● FDA certification label In Japanese In English Micro Laser Distance Sensor [CMOS] HG-C Series ME-HGC1000 No.0059-28V Thank you very much for purchasing Panasonic products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a convenient place for quick reference. In Chinese WARNING ●● This product is for the sensing (determination and measurement) of objects. Do not use this product to secure safety, such as accident prevention which may affect human life and property. ●● Do not stare directly into the laser beam, or through observation optical equipment, such as lenses or etc. as it is dangerous. 1 INTENDED PRODUCTS FOR CE MARKING ●● This product complies with the following standards / regulations. EMC Directive CAN/CSA-C22.2 NO. 60947-5-2-14 2 CONFIRMATION OF PACKED CONTENTS Sensor 1 pc. Laser warning label (JIS Standards, GB Standard) 1 set each FDA certification label 1 pc. Instruction Manual (Japanese, English, Korean) 1 pc. each language General Information for Safety, Compliance, and Instructions (23 languages) 1 pc. 4 PART DESCRIPTION 3 SAFE USE OF LASER PRODUCT Zero set indicator (Yellow) ●● For the purpose of preventing any injury which may occur to the user by the use of the laser product in advance, the following standards have been established by the IEC Standards, JIS Standards, GB Standards and FDA Standards. IEC : IEC 60825-1-2014 JIS : JIS C 6802-2014 GB : GB 7247.1-2012 FDA : PART 1040.10 Class*1 IIa II IIIa IIIb *2 *2 R R*3,4 R R R R R*3,4 R R R R R*3,4 R R R R R*3,4 R R R R*2 R*3,4 R R R Performance (laser system) Remote control connector [1040.10 (f) (3)] Key control [1040.10 (f) (4)] Emission indicator [1040.10 (f) (5)] Beam attenuator [1040.10 (f) (6)] Reset [1040.10 (f) (10)] N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A R R N/A N/A N/A R R N/A R R R*10 R N/A R R R*10 R R*13 S S S S S S S S S S*8 S S S*8 NP S*11 S*8 NP S*11 Labeling (all laser products) Certification / identification [1010.2,3] Protective housing [1040.10 (g) (6), (7)] Aperture [1040.10 (g) (4)] Class warning [1040.10 (g) (1), (2), (3)] R D*5 N/A N/A R R*5 N/A R*6 R R*5 R R*7 R R*5 R R*9 R R*5 R R*12 R R*5 R R*12 Information (all laser products) User information [1040.10 (h) (1)] Product literature [1040.10 (h) (2) (i)] Service information [1040.10 (h) (2) (ii)] R N/A R R R R R R R R R R R R R R R R *2 *2 R : Required N/A : Not applicable S : Same as for other products of that Class. Also see footnotes. NP : Not permitted D : Depends on level of interior radiation. *3 *4 *5 *6 *7 *8 *9 *10 *11 *12 *13 DOWN key 5 MOUNTING ●● When mounting this product, use M3 screws (prepare separately). Use a tightening torque of 0.5N・m for mounting. ●● When mounting this product using the sensor mounting bracket (optional), also use a tightening torque of 0.5N・m. IV R R*3,4 N/A R R *2 UP key : Class is based on the maximum level of laser exposure during operation. : Required wherever and whenever human access to laser radiation above Class I limits is not needed for products to perform its functions. : Required for protective housings opened during operation or maintenance, if human access thus gained is not always necessary when housing is opened. : The requirements for interlock differ depending on the class of inner radiation. : The contents of label differ depending on the level and wavelength of laser radiation inside the protective housing. : Warning statement label. : CAUTION logotype. : The method to measure the level of laser radiation to human body is required. : CAUTION if 2.5mWcm-2 or less, DANGER is greater than 2.5mWcm-2 : Delay required between indication and emission. : Exception should be provided for demonstration of laser products or light shows using laser of Class IIIb or IV. : DANGER logotype. : Required after August 20, 1986. M3 screws (prepare separately) Mounting hole dimensions 37mm I Performance (all laser products) Protective housing [1040.10 (f) (1)] Safety interlocks [1040.10 (f) (2)] Location of controls [1040.10 (f) (7)] Viewing optics [1040.10 (f) (8)] Scanning safeguards [1040.10 (f) (9)] *1 *2 Digital indicator (Red) Output operation indicator (Orange) TEACH key ●● FDA Standards Outline Performance (specific-purpose products) Medical [1040.11 (a)] Measurement, leveling, alignment [1040.11 (b)] Demonstration [1040.11 (c)] PRO indicator (Yellow) Teaching indicator (Yellow) Laser emission indicator (Green) These standards classifies laser products according to the level of hazard and provide the safety measures for respective classes. Requirements ●● An English warning label is attached to this product. When this product is used in Japan or China, peel off the English warning label, and attach the Japanese or Chinese warning label. ●● When exporting this product to the United State of America attach the FDA certification label to the cable close to the sensing device. 18mm Mounting Direction ●● Direction to a movable body • When performing measurements of moving objects with excessively different materials and colors, mount the product per the following directions to minimize measurement errors. • When measuring rotating objects, mount the product as follows. Measurement can be performed with minimized effect on the object caused by up / down deflection, position deviation and etc. • When there is a step in the moving object, mount the product as follows. Measurement can be performed with minimized effect from the edges of the steps. ●● Measuring of narrow locations and recesses • When measuring in narrow locations or inside holes, mount the product so that optical path from the light emitting part to lightreceiving part is not interrupted. ●● Mounting the sensor to a wall • Mount the product as follows, so that the multiple light reflections on the wall do not emit to the lightreceiving part. When the reflection factor on a wall is high, it is effective to use a dull black color. 1-point teaching (Window comparator mode) ●● This is mode is used for setting the threshold range for the distance from the reference value of the sensing object, by performing 1-point teaching. This mode is used for sensing within the threshold range. ●● When performing 1-point teaching (window comparator mode), preset “Window comparator mode 1” in the sensing output setting of the PRO mode. For the setting method, refer to “ 12 PRO MODE SETTING.” 6 I/O CIRCUIT DIAGRAMS OFF Threshold 2_SL ●● NPN Output Type ON (Brown) +V Main circuit (Pink) External input Threshold 1_SL Load + (Black) Control output External input - OFF 12 to 24V DC ±10% (Blue) 0V Sensing object 1. Press the TEACH key twice in the sensing object present condition. (1st time: TEACH mode, 2nd time: Teaching) (Gray) Analog output Analog input device (Shield) Analog ground AGND AGND Reference surface Automatic ●● PNP Output Type 2. Teaching is completed. (Brown) +V External input Main circuit (Black) Control output (Pink) External input - 12 to 24V DC ±10% Load (Blue) 0V (Gray) Analog output Analog input device (Shield) Analog ground AGND AGND + 2-point teaching (Window comparator mode) ●● This is method to set the threshold range by conducting the 2-point teaching. ●● When performing 2-point teaching (window comparator mode), preset “Window comparator mode 2” in the sensing output setting of the PRO mode. For the setting, refer to “ 12 PRO MODE SETTING.” ●● When conducting teaching, use sensing objects (P-1 and P-2) whose distance are different from each other. 7 TEACHING Distance OFF 2-point teaching 1st time (Threshold 1_SL) OFF ●● This is the basic teaching method. Sensing object P-1 2 Distance 1 2nd time (Threshold 2_SL) ON 1. Press the TEACH key in the sensing object P-1 present condition. (1st time) ON Threshold OFF Background Sensing object P-2 Sensing object 2. Press the TEACH key in the sensing object P-2 present condition. (2nd time) 1. Press the TEACH key in the background present condition. Stable sensing is possible 2. Press the TEACH key in the sensing object present condition. Stable sensing is not possible Stable sensing is possible 3-point teaching (Window comparator mode) Stable sensing is not possible Limit-teaching ●● This is teaching method in case small object or object in background are existing. ●● This is the method to perform 3-point teaching (P-1, P-2, P-3) and to set the threshold range by setting threshold 1_SL in the mid-point between the 1st time and 2nd time, and threshold 2_SL in the mid-point between the 2nd time and 3rd time as shown in the following figure. ●● When performing 3-point teaching (window comparator mode), preset “Window comparator mode 3” in the sensing output setting of the PRO mode. For the setting, refer to “ 12 PRO MODE SETTING.” ●● When performing teaching, use sensing objects (P-1, P-2, P-3) with different distance. ●● After teaching, P-1, P-2 and P-3 will be automatically rearranged from the smaller value. Distance UP key Teaching value ON OFF 3rd time Threshold 2_SL 2nd time Threshold 1_SL 1st time Sensing objectSensing object Sensing object P-1 P-2 P-3 Background Distance OFF Distance Threshold 1. Press the TEACH key in the sensing object P-1 present condition. (1st time) Teaching value DOWN key Threshold 2. Press the TEACH key in the sensing object P-2 present condition. (2nd time) Sensing object 1. Press the TEACH key in the background present condition or the sensing object present condition. 3. Press the TEACH key in the sensing object P-3 present condition. (3rd time) 2. When an object in the background is used as a reference, press the UP key to set the threshold on the sensor side. When a sensing object is used as a reference, press the DOWN key to set the threshold on the sensing object side. Stable sensing is possible 3. Teaching is completed. Stable sensing is not possible Automatic Span adjustment in rising differential mode or trailing differential mode 10 ZERO SET FUNCTION ●● This mode is used to cancel the gradual changes in the measured value, and to only detect sudden changes. ●● When performing rising differential mode or trailing differential mode, preset “Rising differential mode” or “Trailing differential mode” in the sensing output setting of the PRO mode. For the setting method, refer to “ 12 PRO MODE SETTING.” ●● The threshold can be set by using the threshold value fine adjustment function. For the threshold value fine adjustment function, refer to “ 8 THRESHOLD VALUE FINE ADJUSTMENT FUNCTION.” ●● The zero set function is the function to compulsorily set the measured value to “zero”. ●● The zero set indicator (yellow) will turn ON when the zero set is valid. ●● When the zero set function is executed while the peak / bottom hold function is valid, the held measured value will be reset. ●● When the display setting is set to Offset, the zero set function cannot be set. Press the UP key and DOWN key simultaneously for 3 seconds. Confirmed 1. Press the TEACH key. 2. Press the UP key or DOWN key to select the span. Short span Press the UP key and DOWN key simultaneously for 6 seconds. Long span Automatic “ “ will be displayed during this period. 3. Press the TEACH key to set. ●● The setting or releasing of the zero set from an external input operates as in the following figure. 10ms or more 1 sec. ON 8 THRESHOLD VALUE FINE ADJUSTMENT FUNCTION OFF ●● Fine adjustment of the threshold can be performed in the measurement display. ●● Fine adjustment of the threshold can be performed even after teaching. Press the UP / DOWN key Press the UP / DOWN key Press the TEACH key Confirmed Automatically set after about 3 seconds. Zero set release Zero set valid period ●● When the power is turned ON again, zero set from external input can be released. At this time, the zero set will not be saved. ●● Even when the zero set is set in the sensor, the zero set can be set or released from an external input. However, when the power is turned ON again, the zero set set in the sensor will be displayed. 11 KEY LOCK FUNCTION ●● The key lock function is to prevent acceptance of key operations, so that the conditions set in each setting mode are not changed accidentally. ●● When key operation is performed after the key lock is set, “ ” will be displayed on the digital display. ●● W hen the sensing output is set to window comparator mode, the display of “ ” and “ ” can be changed by pressing the TEACH key for 1 second. Press the TEACH key for 1 second Zero set setting Change the threshold value Press the TEACH key and DOWN key simultaneously for 3 seconds. Automatic Measurement display Automatic Press the TEACH key and DOWN key simultaneously for 3 seconds. Automatic ●● When performing a fine adjustment of the threshold of “ ” or ”, press the UP key or DOWN key. After “ ” or “ ” is displayed, the fine adjustment of the threshold can be performed. Press down UP / DOWN key Press down UP / DOWN key 12 PRO MODE SETTING Part description Press the TEACH key DOWN key (Select) TEACH key (Confirmed) Automatic Confirmed or (Automatically set after about 3 seconds.) 9 PEAK / BOTTOM HOLD FUNCTION ●● The peak / bottom hold function, is for displaying the peak value and bottom value. ●● When the zero set function is executed while the peak / bottom hold function is set to “Peak hold” or “Bottom hold”, the held measured value will be reset. Default setting Response speed setting Output operation setting Sensing output setting Press the TEACH key Select Confirmed Hysteresis setting or External input setting Digital Display or Automatically set after about 3 seconds. or Description Function : Press UP key or DOWN key : Press DOWN key UP key (Select) Analog output setting Press down UP / DOWN key : Press the TEACH key ●● The PRO indicator (yellow) will turn ON when the PRO mode is set. ●● When the DOWN key is pressed for 3 seconds or more in the middle of the PRO MODE setting, the display returns to the measurement display. Item Press the TEACH key and UP key simultaneously for 3 seconds. Arrow description in figures PRO indicator (Yellow) Timer setting Hold function release Releases the hold status, and outputs the current measured value Display setting Peak hold Holds maximum measured value Hold setting Bottom hold Holds minimum measured value ECO Setting Reset setting Description Set the response time. “ ”: High precision 10ms, “ ”: Standard 5ms “ ”: High speed 1.5ms Select the control output operation mode. “ ”: Light-ON, “ ”: Dark-ON Set the sensing output. “ ”: Normal sensing mode “ ”: 1-point teaching (Window comparator mode) “ ”: 2-point teaching (Window comparator mode) “ ”: 3-point teaching (Window comparator mode) “ ”: Trailing differential mode “ ”: Trailing differential mode Sets the output operation of analog output setting. “ ”: Analog voltage output (0 to +5V) “ ”: Analog current output (4 to 20mA) Set the hysteresis width. HG-C1030: 0.001 to 5.00mm HG-C1050: 0.01 to 15.00mm HG-C1100: 0.02 to 35.00mm HG-C1200: 0.1 to 80.0mm HG-C1400: 0.2 to 200.0mm Set the external input. “ ”: Zero set function, “ ”: Teaching function “ ”: Light emitting stop function, “ ”: Trigger function Set the timer operation. The timer time is fixed at 5ms. “ ”: No timer, “ ”: OFF-delay timer “ ”: ON-delay timer, “ ”: One-shot timer The display of the measured value can be changed. “ ”: Normal, “ ”: Invert, “ ”: Offset Set the control output and the analog output operation when a measurement error occurs (insufficient light intensity, saturation of light intensity, out of measurement range). “ ”: Hold OFF, “ ”: Hold ON The digital display can be set to go OFF when key operation is not performed for 30 seconds. Current consumption can be reduced. “ ”: ECO OFF, “ ”: ECO ON Return to the default setting (factory setting). “ ”: Reset NG, “ ”: Reset OK ●● Do not use this product during the transient state when the power supply is turned ON. ●● The overall length of the cable can be extended to 10m maximum with a cable size of 0.3mm2 or more. ●● Make sure that stress by forcible bend or pulling is not applied to the sensor cable joint. ●● Although it depends on the type, light from rapid start type or high frequency lighting type fluorescent lights, sunlight and etc. may affect the sensing, therefore make sure to prevent direct incident light. ●● This product is suitable for indoor use only. ●● Keep water, oil, fingerprints and etc. which reflect light, or dust, particles or etc. which interrupts the light, away from the emitting / receiving surfaces of this product. If contaminants adhere to the surface, wipe off with a dust-free soft cloth, or lens cleaning paper. ●● Do not use the sensor in locations where there is excessive vapor, dust or etc. or in an atmosphere where corrosive gases, etc. is generated. ●● Take care that the product does not come in contact with oil, grease, organic solvents such as thinner, etc., strong acid or alkaline. ●● Make sure to turn OFF the power supply, before cleaning the light emitting / receiving windows of the sensor head. ●● There is a certain deviation in the directionality of this product. Install the product using a mounting bracket or similar fitting to allow the adjustment of optical axis. ●● The internal memory (nonvolatile) of this product has a service life. Settings cannot be configured more than 100,000 times. Procedure Measurement display DOWN: Press for 3 seconds Response time setting High precision TEACH UP / DOWN Standard UP / DOWN High speed UP / DOWN Output operation setting Light-ON UP / DOWN TEACH UP / DOWN Sensing output setting Normal sensing mode TEACH UP / DOWN Dark-ON 1-point teaching Window comparator mode UP / DOWN 2-point teaching Window comparator mode 14 ERROR INDICATION ●● In case of errors, attempt the following measures. UP / DOWN UP / DOWN Error indication UP / DOWN UP / DOWN Measured value blinks UP / DOWN Trailing differential mode Analog output setting Analog voltage output TEACH 3-point teaching Window comparator mode Rising differential mode UP / DOWN Description Remedy Insufficient amount of reflected light. The sensing object is out of the sensing range. Confirm that the sensing distance is within the specification range. Adjust the installation angle of the sensor. Flash memory is damaged or passed its life expectancy. Please contact our office. Load of the sensing output is short-circuited causing an over-current to flow. Turn OFF the power and check the load. The semiconductor laser is damaged or passed its life expectancy. Please contact our office. • W hen zero set is set, the measurement is not performed normally. • Since the display setting is set to “Offset”, the zero set function can not be used. • C onfirm that the sensing distance is within the specification range. • Set the display to any setting except “Offset.” During teaching, the measurement is not performed normally. Confirm that the sensing distance is within the specification range. System error Please contact our office. Analog current output UP / DOWN Hysteresis setting Hysteresis width TEACH UP key : Increases hysteresis width DOWN key : Decreases hysteresis width 15 SPECIFICATIONS UP / DOWN External input setting Zero set function TEACH UP / DOWN Teaching function UP / DOWN Light emitting stop function UP / DOWN Trigger function UP / DOWN Timer setting No timer TEACH UP / DOWN OFF-delay UP / DOWN ON-delay UP / DOWN One-shot Type NPN output Model No. PNP output Measurement center distance Measurement range Repeatability Linearity UP / DOWN Display setting Normal TEACH UP / DOWN Invert UP / DOWN Offset Light source Beam diameter (Note 3) Supply voltage Power consumption UP / DOWN Hold setting Temperature characteristic Hold OFF TEACH UP / DOWN Hold ON Control output UP / DOWN ECO Setting ECO OFF TEACH UP / DOWN ECO ON UP / DOWN Reset setting Reset NG TEACH UP / DOWN Output operation Short-circuit protection Analog voltage output Analog output Analog current output Response time Reset OK UP / DOWN Response time setting 13 CAUTIONS ●● This product has been developed / produced for industrial use only. ●● Make sure that the power supply is OFF before starting the wiring. ●● If the wiring is performed incorrectly, it will cause a failure. ●● Do not run the wires together with high-voltage lines or power lines, or put them in the same raceway. This can cause malfunction due to induction. ●● Verify that the supply voltage variation is within the rating. ●● If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. ●● If noise generating devices (switching regulators, inverter motors, etc.) are used around the sensor mounting area, make sure to connect the frame ground (FG) terminal of the device. External input Protection Degree of pollution Ambient temperature Ambient humidity Ambient illuminance Operating altitude Cable Material Weight Measurement center 30mm type HG-C1030 HG-C1030-P Measurement center 50mm type HG-C1050 HG-C1050-P Measurement center 100mm type HG-C1100 HG-C1100-P Measurement center 200mm type HG-C1200 HG-C1200-P 30mm 50mm 100mm 200mm 400mm ±5mm ±15mm ±35mm ±80mm 10μm 30μm 70μm 200μm ±200mm 300μm (measurement distance 200 to 400mm) 800μm (measurement distance 400 to 600mm) ±0.2%F.S. (measurement distance 200 to 400mm) ±0.3%F.S. (measurement distance 400 to 600mm) ±0.1%F.S. ±0.2%F.S. Measurement center 400mm type HG-C1400 HG-C1400-P 0.03%F.S./°C Red semiconductor laser Class 2 [JIS / IEC / GB / FDA (Note 2)] Max. output: 1mW, Emission peak wavelength: 655nm Approx. Approx. Approx. Approx. Approx. ø50μm ø70μm ø120μm ø300μm ø500μm 12 to 24V DC ±10%, Ripple P-P 10% or less 40mA or less (at 24V DC supply voltage), 65mA or less (at 12V DC supply voltage) NPN open-collector transistor PNP open-collector transistor • Maximum sink current: 50mA • Maximum source current: 50mA • Applied voltage: 30V DC or less • Applied voltage: 30V DC or less (Between control output to 0V) (Between control output to +V) • Residual voltage: 1.5V or less • Residual voltage: 1.5V or less (At 50mA sink current) (At 50mA source current) • Leakage current: 0.1 mA or less • Leakage current: 0.1 mA or less Switchable either Light-ON or Dark-ON Incorporated (Auto reset type) • Output range: 0 to +5V (at alarm: +5.2V) • Output impedance: 100Ω • Output range: 4 to 20mA (at alarm: 0mA) • Load impedance: 300Ω or less Switchable between 1.5ms / 5ms / 10ms NPN non-contact input PNP non-contact input • Input conditions • Input conditions Invalid: +8 to +V DC or Open Invalid: 0 to +0.6V DC or Open Valid: 0 to +1.2V DC Valid: +4 to +V DC • Input impedance: Approx. 10kΩ • Input impedance: Approx. 10kΩ IP67 (IEC) 2 -10 to +45°C (No dew condensation or icing allowed), Storage: -20 to +60°C 35 to 85% RH, Storage: 35 to 85% RH Incandescent lamp: Acceptance surface illuminance 3,000ℓx or less 2,000m or less 0.2mm2 5-core composite cable, 2m long Enclosure: Aluminum die-cast, Front cover: Acrylic Approx. 35g (without cable), approx. 85g (including cable) Notes: 1) Supply voltage: 24V DC, ambient temperature: +20°C, response time: 10ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. 2) This is based on the FDA Standard, according to Laser Notice No. 50 of the FDA Standard. 3) This is the size in the measurement center distance. These values were defined by using 1/e2 (approx. 13.5%) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. http://panasonic.net/id/pidsx/global Overseas Sales Division (Head Office) 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-568-33-7861 FAX: +81-568-33-8591 For sales network, please visit our website. PRINTED IN CHINA © Panasonic Industrial Devices SUNX Co., Ltd. 2017
HG-C1200 价格&库存

很抱歉,暂时无法提供与“HG-C1200”相匹配的价格&库存,您可以联系我们找货

免费人工找货
HG-C1200
  •  国内价格 香港价格
  • 1+3880.594741+502.45796

库存:4

HG-C1200
  •  国内价格 香港价格
  • 1+4704.943281+609.19430
  • 10+4283.0684210+554.57010

库存:1

HG-C1200
    •  国内价格
    • 1+4752.63572

    库存:24