0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HL-G112-A-C5

HL-G112-A-C5

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SENSOR REFLECTIVE 120MM NPN/PNP

  • 数据手册
  • 价格&库存
HL-G112-A-C5 数据手册
A variety of high-end functions are included in a compact, self-contained body for exceptional ease of use Easy input settings while looking at digital display The built-in digital display makes it easy to perform sensor setting while checking displacement values. 5.5 digit, 7-segment LED display UP key HL-G125-A-C5 HL-G125-S-J Easy to embed in machines and production lines thanks to a built-in controller 20.4 0.803 2-ø 4.5 ø 0.177 51.4 2.024 60 2.362 Beam-receiving axis 47.5 1.870 57 2.244 49.4 1.945 70 47.5 1.8 ft ø6.85 ø0.270 0.5 m 15° Equipped on HL-G125-S-J only ø12.5 ø0.492 4 1. 3 1.6 693 40 ft Specular reflection type Equipped on HL-G103A-RS-J only Lightweight body that can be installed on movable parts Its lightweight resin body weighs 70 g approx., which can be installed on moving parts such as sliders and robot arms. Cable with superior flexibility is fitted as standard. Height: 60 mm 2.362 in Ideal for measuring mirrored objects 62.4 2.457 33 1.299 0 64 1. ø12.5 ø0.492 43 93 6 1. HL-G1 2-ø 4.5 ø 0.177 72.3 2.846 Beamreceiving axis m Amplifier separated type sensor Depth: 57 mm 2.244 in Diffuse reflection type 66.6 2.622 34.41 1.355 Flexible cable HL-G105A-RA-C5 HL-G105A-RS-J 5.5 digit LED display (Red) Alarm indicator (Orange) Laser emission indicator (Green) 20.4 0.803 64.2 2.528 39.32 1.548 Software tool for sensor configuration and evaluation In addition to configuring up to 16 sensors at once, this free tool makes it easy to gather data needed for analysis, such as received light waveform monitoring and data buffering. The interface language can be selected at the time of installation. ● Data buffering Stores and displays measurement data, which can be superimposed on previously recorded data for easy comparison and analysis. ● Received light waveform display Displays the amount of light received by cell from light-receiving element. ● Measured value display Displays measured values as well as the output state for each terminal. HMI screen data for sensor setting and data indication The GT02 / GT12 series HMI can be used in combination with the HL-G1 to allow easy confirmation of sensor status and configuration of sensor settings from a remote location. Japanese, English, Chinese, and Korean are supported. For more information about the GT series, visit our website or refer to our catalog. Select from the following HMI operator panels: Power supply: 24 V Communication port: RS422 (RS485) ● AIG02GQ14D ● AIG02MQ15D ● AIG12GQ14D / AIG12GQ15D ● AIG12MQ14D / AIG12MQ15D 66.8 2.630 Beamreceiving axis 7.53° ø12.5 ø0.492 ø6.85 ø0.270 0. 5 m 4 1. 1.6 3 64 93 0 ft ø12.5 ø0.492 L Model No. L HL-G1CCJ2 2,000 +2000 78.740 +7.8740 5,000 +5000 196.850 +19.6850 10,000 +1,0000 393.701 +39.3700 20,000 +2,0000 787.402 +78.7400 2013.12 31.2 1.228 Equipped on HL-G108A-RS-J only Extension cable HL-G1CCJ10 66.8 2.630 57.4 2.260 Extension cable (optional) (43 1.693) ø 12.5 ø 0.492 panasonic.net/id/pidsx/global ø 6.85 ø 0.270 cable 14-core × 0.1 mm2 Insulator diameter: ø 0.7 mm ø 0.028 in (RS-422/485 communication cable: ø 1.0 mm ø 0.039 in) (50 1.969) Panasonic Industrial Devices SUNX Co., Ltd. Global Sales Department Sensor configuration and evaluation software tool, HMI screen data, function blocks, etc. Terms of use Panasonic Industrial Devices SUNX offers no warranty for this software and is not liable for any loss or damage suffered as a result of its use or operation, whether direct, indirect, incidental, consequential, or unforeseen. ø6.85 ø0.270 0.5 4 m 1.6 1.693 3 40 ft 2-ø 4.5 ø 0.177 15.05° HL-G1CCJ□ HL-G1CCJ20 Software is available for download. Beam-emitting axis Equipped on HL-G105A-RS-J only HL-G1CCJ5 62.3 2.453 42.24 1.663 47.5 1.870 10.39° OUT 1 indicator (Yellow) OUT 2 indicator (Yellow) OUT 3 indicator (Yellow) UP key DOWN key Measurement center distance 82.9 3.264 10.75 0.423 20.4 0.803 69 2.717 59.5 2.343 32.8 1.291 69 2.717 Sensor head ENTER key 2-ø 4.5 ø 0.177 20.77° Beamreceiving axis 5.5 digit LED display (Red) Alarm indicator (Orange) Laser emission indicator (Green) UP key DOWN key 47.5 1.870 Thanks to its IP67 protective enclosure, the HL-G1 can be used in the presence of water and dust. Mounting holes are lined with metal sleeves, allowing the instrument to be tightened securely in place with up to 0.8 N·m of torque. Measurement center distance 47.3 1.862 13.4 0.528 Beam-emitting axis HL-G108A-RA-C5 HL-G108A-RS-J OUT 1 indicator (Yellow) OUT 2 indicator (Yellow) OUT 3 indicator (Yellow) ENTER key IP67 protective enclosure protects from water and dust Sensor head No.CE-HLG1A-4 December, 2013 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Telephone: +81-568-33-7861 Facsimile: +81-568-33-8591 All Rights Reserved ©Panasonic Industrial Devices SUNX Co., Ltd. 2013 Ŷ Laser Displacement Sensor Diffuse reflection type HL-G125Ƒ Specular reflection type HL-G10ƑAƑ Measure distances as long as 250mm 30° 4.3 ø 6.85 ø 0.270 0.169 Width: 20.4 mm 0.803 in New models UP key DOWN key Measurement center distance 26.3 1.035 17.5 0.689 Beamemitting axis 72.3 2.846 5 0. DOWN key Sensor head OUT 1 indicator (Yellow) OUT 2 indicator (Yellow) OUT 3 indicator (Yellow) ENTER key UP key DOWN key Measurement center distance 250 9.843 3.8 Beam0.150 emitting axis 6.2° 20.4 0.803 HL-G103A-RA-C5 HL-G103A-RS-J 5.5 digit LED display (Red) Alarm indicator (Orange) Laser emission indicator (Green) OUT 1 indicator (Yellow) OUT 2 indicator (Yellow) OUT 3 indicator (Yellow) ENTER key Controller installation and mounting space is not required because controller function is included in sensor unit. ENTER key Sensor head 5.5 digit LED display (Red) Alarm indicator (Orange) Laser emission indicator (Green) Compact For dimensions of the diffuse reflection type (other than the HL-G125□), refer to the HL-G1 catalog or our website. CAD data for dimensional diagrams can be downloaded from our website. DIMENSIONS (Unit: mm in) Ŷ 2013.12 panasonic.net/id/pidsx/global Conforming to EMC Directive Conforming to FDA regulations Measurement range: 26.3 ±2 mm 1.035 ±0.079 in 0.5 μm 0.020 mil Resolution: Linearity: ±0.2 % F.S. Beam diameter: 0.1 × 0.1 mm 0.004 × 0.004 in 30 mm 1.181 in 50 mm 1.969 in 85 mm 3.346 in 120 mm 4.724 in 250 mm 9.843 in 26.3 mm 1.035 in 47.3 mm 1.862 in 82.9 mm 3.264 in Measuring range ±4 mm ±0.157 in ±10 mm ±0.394 in ±20 mm ±0.787 in ±60 mm ±2.362 in ±150 mm ±5.906 in ±2 mm ±0.079 in ±5 mm ±0.197 in ±10 mm ±0.394 in Resolution 0.5 μm 0.020 mil 1.5 μm 0.059 mil 2.5 μm 0.098 mil 8 μm 0.315 mil 20 μm 0.787 mil 0.5 μm 0.020 mil 1.5 μm 0.059 mil 2.5 μm 0.098 mil Linearity ±0.1 % F.S. ±0.3 % F.S. Temprerature characteristics Light source Beam diameter (Note 2) Controlling the height of a dispenser nozzle Measuring HDD surface fluctuation Specular reflection type HL-G105□ HL-G105A□ Measurement range: 50 ±10mm 1.969 ±0.394 in 1.5 μm 0.059 mil Resolution: Linearity: ±0.1 % F.S. Beam diameter: 0.5 × 1.0 mm 0.020 × 0.039 in Measurement range: 47.3 ±5 mm 1.862 ±0.197 in 1.5 μm 0.059 mil Resolution: Linearity: ±0.2 % F.S. Beam diameter: 0.1 × 0.1 mm 0.004 × 0.004 in 0.1 × 0.1 mm 0.5 ×1.0 mm 0.75 × 1.25 mm 1.0 × 1.5 mm 1.75 × 3.5 mm 0.004 × 0.004 in 0.020 × 0.039 in 0.030 × 0.049 in 0.039 × 0.059 in 0.069 × 0.138 in Sampling rate 200 μs, 500 μs, 1 ms, 2 ms Output range: 3.2 to 20.8 mA (normal) / 21.6 mA (at alarm), Load impedance: 300 Ω max. • Maximum sink current : 50 mA • Applied voltage : 3 to 24 V DC (between output and 0 V) • Residual voltage : 2 V or less (at 50 mA of sink current) HL-G108A□ Multi input Measurement range: 85 ±20 mm 3.346 ±0.787 in 2.5 μm 0.098 mil Resolution: Linearity: ±0.1 % F.S. Beam diameter: 0.75 ×1.25 mm 0.030×0.049 in Measurement range: 82.9 ±10 mm 3.264 ±0.394 in 2.5 μm 0.098 mil Resolution: Linearity: ±0.2 % F.S. Beam diameter: 0.2 × 0.2 mm 0.008 × 0.008 in Communications interface (high-function type only) Indicator HL-G108□ Open when the output is ON. NPN open collector output operates when 0 V is connected. PNP open collector output operates when 24 V DC is connected. NPN output operates when 0 V is connected and NPN is set (depending on settings). PNP output operates when external power + is connected and PNP is set (depending on settings). Zero set, zero set off, reset, memory switching, teaching, saving, and laser control according to the input time. In case NPN output is selected, function varies according to the time 0 V is connected NPN. In case PNP output is selected, function varies according to the time external power + is connected. RS-422 or RS-485 (selectable) Baud rate: 9,600 / 19,200 / 38,400 / 115,200 / 230,400 / 460,800 / 921,600 bps Data length 8 bit, stop bit length 1 bit, without parity check, BCC check, termination code: CR Laser emission Orange LED (lights up when this product cannot measure because of insufficient or excessive light intensity) Output Yellow LED x 3 Cable Cable extension Weight HL-G112□ Measurement range: 120 ±60 mm 4.724 ±2.362 in 8 μm 0.315 mil Resolution: Linearity: ±0.1 % F.S. Beam diameter: 1.0 × 1.5 mm 0.039 × 0.059 in Enclosure: PBT, front cover: acrylic, cable: PVC Standard type: 0.1 mm2 10-core cabtyre cable, 5 m 16.404 ft long, high functionality type: 14-core cabtyre cable with connector, 0.5 m 1.640 ft long Extension up to total 20 m 65.617 ft is possible with optional cable (Cable for standard type cannot be extended). Standard type Net weight: 70 g approx. (not including cable), 320 g approx. (including cable), gross weight: 380 g approx. High functionality type Net weight: 70 g approx. (not including cable), 110 g approx. (including cable), gross weight: 160 g approx. Warning label: 1 set Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 °C +68 °F, sampling rate 500 μs, average number of samples: 1024, measurement center distance, object measured is made of white ceramic and analog measurement values. 2) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity. The results may be affected if there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself. OPTIONS Diffuse reflection type HL-G125□ Type Measurement range: 250 ±150 mm 9.843 ±5.906 in 20 μm 0.787 mil Resolution: Linearity: ±0.3 % F.S. Beam diameter: 1.75 × 3.5 mm 0.069 × 0.138 in Extension cable (for High function type) Testing sheet slack 0 í0.4 í150 í5.906 0.2   150 5.906 0.2 í0.4 í150 í5.906 í 0 í (Center)   150 5.906 í0.4 í2.0 í0.079 0.2 0 í0.2 0 í0.2 í 0 í (Center) 2.5  5.0 0.197 í0.4 í5.0 í0.197 í 0 í (Center)   2.0 0.079 í0.4 í2.0 í0.079 í 0 í (Center) 2.5  5.0 0.197 Measuring distance L (mm in) 2.0 0.079 Horizontal positioning 0.4 0.1° 0° í0.1° 6DPSOLQJUDWHȝV Average number of samples: 1024 0 í0.4 í10.0 í0.394   Specular reflection type í0.2 6DPSOLQJUDWHȝV Average number of samples: 1024 í 0 í (Center) Measuring distance L (mm in) 0.4 0.2 6DPSOLQJUDWHȝV Average number of VDPSOHV í0.2 Vertical positioning 0.05° 0° í0.05° ƒ ƒ íƒ 0 HL-G108A-R□ Horizontal positioning 6DPSOLQJUDWHȝV Average number of samples: 1024 0.2 Measuring distance L (mm in) 0.4 0.1° 0° í0.1° 6DPSOLQJUDWHȝV Average number of VDPSOHV í0.2 Specular reflection type 0.4 Horizontal positioning 0.4 0.5° 0° í0.5° 0 Measuring distance L (mm in) Vertical positioning í0.4 í5.0 í0.197 6DPSOLQJUDWHȝV Average number of samples: 1024 0 0HDVXULQJGLVWDQFH/ PPin) 0.2 Vertical positioning 0.4 10° 0° í10° í0.2 í 0 í (Center) Specular reflection type 0.2 ƒ ƒ íƒ 6DPSOLQJUDWHȝV Average number of samples: 1024 0 í0.2 í 0 í (Center)   Measuring distance L (mm in) 10.0 0.394 í0.4 í10.0 í0.394 í 0  í (Center)  Measuring distance L (mm in) 10.0 0.394 IP67 (IEC) –10 to +45 °C +14 to +113 °F (No dew condensation), Storage: –20 to +60 °C –4 to +140 °F (No dew condensation) Accessory Detecting rotating direction of fan 6DPSOLQJUDWHȝV Average number of VDPSOHV Measuring distance L (mm in) Red LED 5.5 digit display Protection Material Diffuse reflection type Horizontal positioning 0.4 10° 0° í10° Green LED (lights up during laser emission) Alarm Ambient temperature 9HUWLFDOSRVLWLRQLQJ HL-G105A-R□ Incorporated (automatic restoration) Digital display Measuring the eccentricity of a metal shaft • Maximum source current : 50 mA • Residual voltage : 2.8 V or less (at 50 mA of source current) HL-G103A-R□ Diffuse reflection type í Judgment output or alarm output (setting selectable) NPN transistor, open-collector / PNP transistor, open-collector (selectable) Specular reflection type HL-G125□  Current Diffuse reflection type L Measuring object 0.4 Output range: 0 to 10.5 V (normal) / 11 V (at alarm), Output impedance: 100 Ω Timing input Detecting presence of O-ring 0.2 × 0.2 mm 0.008 × 0.008 in Voltage Output polarity setting input L 100 mA max. Short circuit protection Positioning of wafer í Sensor head Measuring object 24 V DC ±10 % including ripple 0.5 V (P-P) Output operation Inspecting processed food quantities 0.1 × 0.1 mm 0.004 × 0.004 in CMOS image sensor Current consumption Output (OUT 1, OUT 2, OUT 3) + ±0.08 % F.S. / °C Receiving element Analog output + Sensor head ±0.2 % F.S. Red semiconductor laser, Class 2 (Class 1 for specular reflection type) (IEC / JIS / FDA, Laser Notice No. 50) Max. output: 1 mW (0.39mW for specular reflection type) Peak emission wavelength: 655 nm 0.026 mil Supply voltage Diffuse reflection type í White ceramic Horizontal orientation Error (% F.S.) Measurement range: 30 ±4 mm 1.181 ±0.157 in 0.5 μm 0.020 mil Resolution: Linearity: ±0.1 % F.S. Beam diameter: 0.1 × 0.1 mm 0.004 × 0.004 in Measurement center distance White ceramic Vertical orientation Error (% F.S.) HL-G103A□ High function type HL-G103-S-J HL-G105-S-J HL-G108-S-J HL-G112-S-J HL-G125-S-J HL-G103A-RS-J HL-G105A-RS-J HL-G108A-RS-J Error (% F.S.) HL-G103□ Correlation between measuring distance and error characteristics Standard type HL-G103-A-C5 HL-G105-A-C5 HL-G108-A-C5 HL-G112-A-C5 HL-G125-A-C5 HL-G103A-RA-C5 HL-G105A-RA-C5 HL-G108A-RA-C5 Error (% F.S.) Specular reflection type Specular reflection type Error (% F.S.) Item Diffuse reflection type Error (% F.S.) Model No. Type For sensing characteristics diagrams for the diffuse reflection type (other than the HL-G125□), refer to the HL-G1 catalog or our website. SENSING CHARACTERISTICS (TYPICAL) Error (% F.S.) A total of 8 models accommodate a variety of applications Diffuse reflection type For more information about I/O circuit diagrams and communication specifications of the high-function type, refer to the HL-G1 catalog or our website. SPECIFICATIONS Error (% F.S.) Extensive selection Appearance Model No. Description HL-G1CCJ2 Length: 2 m 6.562 ft, Weight: 130 g approx. HL-G1CCJ5 Length: 5 m 16.404 ft, Weight: 320 g approx. HL-G1CCJ10 Length: 10 m 32.808 ft, Weight: 630 g approx. HL-G1CCJ20 Length: 20 m 65.617 ft, Weight: 1300 g approx. 14-core cabtyre cable with connector on both ends PRECAUTIONS FOR PROPER USE • This product has been developed / produced for industrial use. • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. • Do not operate products using methods other than the ones described in the instruction manual included with each product. Control or adjustment through procedures other than the ones specified may cause hazardous laser radiation exposure. • The following label is attached to the product. Handle the product according to the instruction given on the warning label. The Japanes, English, Chinese, Korean warning label is packed with the sensor. ( ) • This product is classified as a Class 2 (specular reflection type: Class 1) Laser Product under IEC / JIS standards and FDA regulations. Do not look at the laser beam directly or through an optical system such as a lens. (A Class 2 label is shown above.) Measurement range: 26.3 ±2 mm 1.035 ±0.079 in 0.5 μm 0.020 mil Resolution: Linearity: ±0.2 % F.S. Beam diameter: 0.1 × 0.1 mm 0.004 × 0.004 in 30 mm 1.181 in 50 mm 1.969 in 85 mm 3.346 in 120 mm 4.724 in 250 mm 9.843 in 26.3 mm 1.035 in 47.3 mm 1.862 in 82.9 mm 3.264 in Measuring range ±4 mm ±0.157 in ±10 mm ±0.394 in ±20 mm ±0.787 in ±60 mm ±2.362 in ±150 mm ±5.906 in ±2 mm ±0.079 in ±5 mm ±0.197 in ±10 mm ±0.394 in Resolution 0.5 μm 0.020 mil 1.5 μm 0.059 mil 2.5 μm 0.098 mil 8 μm 0.315 mil 20 μm 0.787 mil 0.5 μm 0.020 mil 1.5 μm 0.059 mil 2.5 μm 0.098 mil Linearity ±0.1 % F.S. ±0.3 % F.S. Temprerature characteristics Light source Beam diameter (Note 2) Controlling the height of a dispenser nozzle Measuring HDD surface fluctuation Specular reflection type HL-G105□ HL-G105A□ Measurement range: 50 ±10mm 1.969 ±0.394 in 1.5 μm 0.059 mil Resolution: Linearity: ±0.1 % F.S. Beam diameter: 0.5 × 1.0 mm 0.020 × 0.039 in Measurement range: 47.3 ±5 mm 1.862 ±0.197 in 1.5 μm 0.059 mil Resolution: Linearity: ±0.2 % F.S. Beam diameter: 0.1 × 0.1 mm 0.004 × 0.004 in 0.1 × 0.1 mm 0.5 ×1.0 mm 0.75 × 1.25 mm 1.0 × 1.5 mm 1.75 × 3.5 mm 0.004 × 0.004 in 0.020 × 0.039 in 0.030 × 0.049 in 0.039 × 0.059 in 0.069 × 0.138 in Sampling rate 200 μs, 500 μs, 1 ms, 2 ms Output range: 3.2 to 20.8 mA (normal) / 21.6 mA (at alarm), Load impedance: 300 Ω max. • Maximum sink current : 50 mA • Applied voltage : 3 to 24 V DC (between output and 0 V) • Residual voltage : 2 V or less (at 50 mA of sink current) HL-G108A□ Multi input Measurement range: 85 ±20 mm 3.346 ±0.787 in 2.5 μm 0.098 mil Resolution: Linearity: ±0.1 % F.S. Beam diameter: 0.75 ×1.25 mm 0.030×0.049 in Measurement range: 82.9 ±10 mm 3.264 ±0.394 in 2.5 μm 0.098 mil Resolution: Linearity: ±0.2 % F.S. Beam diameter: 0.2 × 0.2 mm 0.008 × 0.008 in Communications interface (high-function type only) Indicator HL-G108□ Open when the output is ON. NPN open collector output operates when 0 V is connected. PNP open collector output operates when 24 V DC is connected. NPN output operates when 0 V is connected and NPN is set (depending on settings). PNP output operates when external power + is connected and PNP is set (depending on settings). Zero set, zero set off, reset, memory switching, teaching, saving, and laser control according to the input time. In case NPN output is selected, function varies according to the time 0 V is connected NPN. In case PNP output is selected, function varies according to the time external power + is connected. RS-422 or RS-485 (selectable) Baud rate: 9,600 / 19,200 / 38,400 / 115,200 / 230,400 / 460,800 / 921,600 bps Data length 8 bit, stop bit length 1 bit, without parity check, BCC check, termination code: CR Laser emission Orange LED (lights up when this product cannot measure because of insufficient or excessive light intensity) Output Yellow LED x 3 Cable Cable extension Weight HL-G112□ Measurement range: 120 ±60 mm 4.724 ±2.362 in 8 μm 0.315 mil Resolution: Linearity: ±0.1 % F.S. Beam diameter: 1.0 × 1.5 mm 0.039 × 0.059 in Enclosure: PBT, front cover: acrylic, cable: PVC Standard type: 0.1 mm2 10-core cabtyre cable, 5 m 16.404 ft long, high functionality type: 14-core cabtyre cable with connector, 0.5 m 1.640 ft long Extension up to total 20 m 65.617 ft is possible with optional cable (Cable for standard type cannot be extended). Standard type Net weight: 70 g approx. (not including cable), 320 g approx. (including cable), gross weight: 380 g approx. High functionality type Net weight: 70 g approx. (not including cable), 110 g approx. (including cable), gross weight: 160 g approx. Warning label: 1 set Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 °C +68 °F, sampling rate 500 μs, average number of samples: 1024, measurement center distance, object measured is made of white ceramic and analog measurement values. 2) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity. The results may be affected if there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself. OPTIONS Diffuse reflection type HL-G125□ Type Measurement range: 250 ±150 mm 9.843 ±5.906 in 20 μm 0.787 mil Resolution: Linearity: ±0.3 % F.S. Beam diameter: 1.75 × 3.5 mm 0.069 × 0.138 in Extension cable (for High function type) Testing sheet slack 0 í0.4 í150 í5.906 0.2   150 5.906 0.2 í0.4 í150 í5.906 í 0 í (Center)   150 5.906 í0.4 í2.0 í0.079 0.2 0 í0.2 0 í0.2 í 0 í (Center) 2.5  5.0 0.197 í0.4 í5.0 í0.197 í 0 í (Center)   2.0 0.079 í0.4 í2.0 í0.079 í 0 í (Center) 2.5  5.0 0.197 Measuring distance L (mm in) 2.0 0.079 Horizontal positioning 0.4 0.1° 0° í0.1° 6DPSOLQJUDWHȝV Average number of samples: 1024 0 í0.4 í10.0 í0.394   Specular reflection type í0.2 6DPSOLQJUDWHȝV Average number of samples: 1024 í 0 í (Center) Measuring distance L (mm in) 0.4 0.2 6DPSOLQJUDWHȝV Average number of VDPSOHV í0.2 Vertical positioning 0.05° 0° í0.05° ƒ ƒ íƒ 0 HL-G108A-R□ Horizontal positioning 6DPSOLQJUDWHȝV Average number of samples: 1024 0.2 Measuring distance L (mm in) 0.4 0.1° 0° í0.1° 6DPSOLQJUDWHȝV Average number of VDPSOHV í0.2 Specular reflection type 0.4 Horizontal positioning 0.4 0.5° 0° í0.5° 0 Measuring distance L (mm in) Vertical positioning í0.4 í5.0 í0.197 6DPSOLQJUDWHȝV Average number of samples: 1024 0 0HDVXULQJGLVWDQFH/ PPin) 0.2 Vertical positioning 0.4 10° 0° í10° í0.2 í 0 í (Center) Specular reflection type 0.2 ƒ ƒ íƒ 6DPSOLQJUDWHȝV Average number of samples: 1024 0 í0.2 í 0 í (Center)   Measuring distance L (mm in) 10.0 0.394 í0.4 í10.0 í0.394 í 0  í (Center)  Measuring distance L (mm in) 10.0 0.394 IP67 (IEC) –10 to +45 °C +14 to +113 °F (No dew condensation), Storage: –20 to +60 °C –4 to +140 °F (No dew condensation) Accessory Detecting rotating direction of fan 6DPSOLQJUDWHȝV Average number of VDPSOHV Measuring distance L (mm in) Red LED 5.5 digit display Protection Material Diffuse reflection type Horizontal positioning 0.4 10° 0° í10° Green LED (lights up during laser emission) Alarm Ambient temperature 9HUWLFDOSRVLWLRQLQJ HL-G105A-R□ Incorporated (automatic restoration) Digital display Measuring the eccentricity of a metal shaft • Maximum source current : 50 mA • Residual voltage : 2.8 V or less (at 50 mA of source current) HL-G103A-R□ Diffuse reflection type í Judgment output or alarm output (setting selectable) NPN transistor, open-collector / PNP transistor, open-collector (selectable) Specular reflection type HL-G125□  Current Diffuse reflection type L Measuring object 0.4 Output range: 0 to 10.5 V (normal) / 11 V (at alarm), Output impedance: 100 Ω Timing input Detecting presence of O-ring 0.2 × 0.2 mm 0.008 × 0.008 in Voltage Output polarity setting input L 100 mA max. Short circuit protection Positioning of wafer í Sensor head Measuring object 24 V DC ±10 % including ripple 0.5 V (P-P) Output operation Inspecting processed food quantities 0.1 × 0.1 mm 0.004 × 0.004 in CMOS image sensor Current consumption Output (OUT 1, OUT 2, OUT 3) + ±0.08 % F.S. / °C Receiving element Analog output + Sensor head ±0.2 % F.S. Red semiconductor laser, Class 2 (Class 1 for specular reflection type) (IEC / JIS / FDA, Laser Notice No. 50) Max. output: 1 mW (0.39mW for specular reflection type) Peak emission wavelength: 655 nm 0.026 mil Supply voltage Diffuse reflection type í White ceramic Horizontal orientation Error (% F.S.) Measurement range: 30 ±4 mm 1.181 ±0.157 in 0.5 μm 0.020 mil Resolution: Linearity: ±0.1 % F.S. Beam diameter: 0.1 × 0.1 mm 0.004 × 0.004 in Measurement center distance White ceramic Vertical orientation Error (% F.S.) HL-G103A□ High function type HL-G103-S-J HL-G105-S-J HL-G108-S-J HL-G112-S-J HL-G125-S-J HL-G103A-RS-J HL-G105A-RS-J HL-G108A-RS-J Error (% F.S.) HL-G103□ Correlation between measuring distance and error characteristics Standard type HL-G103-A-C5 HL-G105-A-C5 HL-G108-A-C5 HL-G112-A-C5 HL-G125-A-C5 HL-G103A-RA-C5 HL-G105A-RA-C5 HL-G108A-RA-C5 Error (% F.S.) Specular reflection type Specular reflection type Error (% F.S.) Item Diffuse reflection type Error (% F.S.) Model No. Type For sensing characteristics diagrams for the diffuse reflection type (other than the HL-G125□), refer to the HL-G1 catalog or our website. SENSING CHARACTERISTICS (TYPICAL) Error (% F.S.) A total of 8 models accommodate a variety of applications Diffuse reflection type For more information about I/O circuit diagrams and communication specifications of the high-function type, refer to the HL-G1 catalog or our website. SPECIFICATIONS Error (% F.S.) Extensive selection Appearance Model No. Description HL-G1CCJ2 Length: 2 m 6.562 ft, Weight: 130 g approx. HL-G1CCJ5 Length: 5 m 16.404 ft, Weight: 320 g approx. HL-G1CCJ10 Length: 10 m 32.808 ft, Weight: 630 g approx. HL-G1CCJ20 Length: 20 m 65.617 ft, Weight: 1300 g approx. 14-core cabtyre cable with connector on both ends PRECAUTIONS FOR PROPER USE • This product has been developed / produced for industrial use. • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. • Do not operate products using methods other than the ones described in the instruction manual included with each product. Control or adjustment through procedures other than the ones specified may cause hazardous laser radiation exposure. • The following label is attached to the product. Handle the product according to the instruction given on the warning label. The Japanes, English, Chinese, Korean warning label is packed with the sensor. ( ) • This product is classified as a Class 2 (specular reflection type: Class 1) Laser Product under IEC / JIS standards and FDA regulations. Do not look at the laser beam directly or through an optical system such as a lens. (A Class 2 label is shown above.) Measurement range: 26.3 ±2 mm 1.035 ±0.079 in 0.5 μm 0.020 mil Resolution: Linearity: ±0.2 % F.S. Beam diameter: 0.1 × 0.1 mm 0.004 × 0.004 in 30 mm 1.181 in 50 mm 1.969 in 85 mm 3.346 in 120 mm 4.724 in 250 mm 9.843 in 26.3 mm 1.035 in 47.3 mm 1.862 in 82.9 mm 3.264 in Measuring range ±4 mm ±0.157 in ±10 mm ±0.394 in ±20 mm ±0.787 in ±60 mm ±2.362 in ±150 mm ±5.906 in ±2 mm ±0.079 in ±5 mm ±0.197 in ±10 mm ±0.394 in Resolution 0.5 μm 0.020 mil 1.5 μm 0.059 mil 2.5 μm 0.098 mil 8 μm 0.315 mil 20 μm 0.787 mil 0.5 μm 0.020 mil 1.5 μm 0.059 mil 2.5 μm 0.098 mil Linearity ±0.1 % F.S. ±0.3 % F.S. Temprerature characteristics Light source Beam diameter (Note 2) Controlling the height of a dispenser nozzle Measuring HDD surface fluctuation Specular reflection type HL-G105□ HL-G105A□ Measurement range: 50 ±10mm 1.969 ±0.394 in 1.5 μm 0.059 mil Resolution: Linearity: ±0.1 % F.S. Beam diameter: 0.5 × 1.0 mm 0.020 × 0.039 in Measurement range: 47.3 ±5 mm 1.862 ±0.197 in 1.5 μm 0.059 mil Resolution: Linearity: ±0.2 % F.S. Beam diameter: 0.1 × 0.1 mm 0.004 × 0.004 in 0.1 × 0.1 mm 0.5 ×1.0 mm 0.75 × 1.25 mm 1.0 × 1.5 mm 1.75 × 3.5 mm 0.004 × 0.004 in 0.020 × 0.039 in 0.030 × 0.049 in 0.039 × 0.059 in 0.069 × 0.138 in Sampling rate 200 μs, 500 μs, 1 ms, 2 ms Output range: 3.2 to 20.8 mA (normal) / 21.6 mA (at alarm), Load impedance: 300 Ω max. • Maximum sink current : 50 mA • Applied voltage : 3 to 24 V DC (between output and 0 V) • Residual voltage : 2 V or less (at 50 mA of sink current) HL-G108A□ Multi input Measurement range: 85 ±20 mm 3.346 ±0.787 in 2.5 μm 0.098 mil Resolution: Linearity: ±0.1 % F.S. Beam diameter: 0.75 ×1.25 mm 0.030×0.049 in Measurement range: 82.9 ±10 mm 3.264 ±0.394 in 2.5 μm 0.098 mil Resolution: Linearity: ±0.2 % F.S. Beam diameter: 0.2 × 0.2 mm 0.008 × 0.008 in Communications interface (high-function type only) Indicator HL-G108□ Open when the output is ON. NPN open collector output operates when 0 V is connected. PNP open collector output operates when 24 V DC is connected. NPN output operates when 0 V is connected and NPN is set (depending on settings). PNP output operates when external power + is connected and PNP is set (depending on settings). Zero set, zero set off, reset, memory switching, teaching, saving, and laser control according to the input time. In case NPN output is selected, function varies according to the time 0 V is connected NPN. In case PNP output is selected, function varies according to the time external power + is connected. RS-422 or RS-485 (selectable) Baud rate: 9,600 / 19,200 / 38,400 / 115,200 / 230,400 / 460,800 / 921,600 bps Data length 8 bit, stop bit length 1 bit, without parity check, BCC check, termination code: CR Laser emission Orange LED (lights up when this product cannot measure because of insufficient or excessive light intensity) Output Yellow LED x 3 Cable Cable extension Weight HL-G112□ Measurement range: 120 ±60 mm 4.724 ±2.362 in 8 μm 0.315 mil Resolution: Linearity: ±0.1 % F.S. Beam diameter: 1.0 × 1.5 mm 0.039 × 0.059 in Enclosure: PBT, front cover: acrylic, cable: PVC Standard type: 0.1 mm2 10-core cabtyre cable, 5 m 16.404 ft long, high functionality type: 14-core cabtyre cable with connector, 0.5 m 1.640 ft long Extension up to total 20 m 65.617 ft is possible with optional cable (Cable for standard type cannot be extended). Standard type Net weight: 70 g approx. (not including cable), 320 g approx. (including cable), gross weight: 380 g approx. High functionality type Net weight: 70 g approx. (not including cable), 110 g approx. (including cable), gross weight: 160 g approx. Warning label: 1 set Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 °C +68 °F, sampling rate 500 μs, average number of samples: 1024, measurement center distance, object measured is made of white ceramic and analog measurement values. 2) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity. The results may be affected if there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself. OPTIONS Diffuse reflection type HL-G125□ Type Measurement range: 250 ±150 mm 9.843 ±5.906 in 20 μm 0.787 mil Resolution: Linearity: ±0.3 % F.S. Beam diameter: 1.75 × 3.5 mm 0.069 × 0.138 in Extension cable (for High function type) Testing sheet slack 0 í0.4 í150 í5.906 0.2   150 5.906 0.2 í0.4 í150 í5.906 í 0 í (Center)   150 5.906 í0.4 í2.0 í0.079 0.2 0 í0.2 0 í0.2 í 0 í (Center) 2.5  5.0 0.197 í0.4 í5.0 í0.197 í 0 í (Center)   2.0 0.079 í0.4 í2.0 í0.079 í 0 í (Center) 2.5  5.0 0.197 Measuring distance L (mm in) 2.0 0.079 Horizontal positioning 0.4 0.1° 0° í0.1° 6DPSOLQJUDWHȝV Average number of samples: 1024 0 í0.4 í10.0 í0.394   Specular reflection type í0.2 6DPSOLQJUDWHȝV Average number of samples: 1024 í 0 í (Center) Measuring distance L (mm in) 0.4 0.2 6DPSOLQJUDWHȝV Average number of VDPSOHV í0.2 Vertical positioning 0.05° 0° í0.05° ƒ ƒ íƒ 0 HL-G108A-R□ Horizontal positioning 6DPSOLQJUDWHȝV Average number of samples: 1024 0.2 Measuring distance L (mm in) 0.4 0.1° 0° í0.1° 6DPSOLQJUDWHȝV Average number of VDPSOHV í0.2 Specular reflection type 0.4 Horizontal positioning 0.4 0.5° 0° í0.5° 0 Measuring distance L (mm in) Vertical positioning í0.4 í5.0 í0.197 6DPSOLQJUDWHȝV Average number of samples: 1024 0 0HDVXULQJGLVWDQFH/ PPin) 0.2 Vertical positioning 0.4 10° 0° í10° í0.2 í 0 í (Center) Specular reflection type 0.2 ƒ ƒ íƒ 6DPSOLQJUDWHȝV Average number of samples: 1024 0 í0.2 í 0 í (Center)   Measuring distance L (mm in) 10.0 0.394 í0.4 í10.0 í0.394 í 0  í (Center)  Measuring distance L (mm in) 10.0 0.394 IP67 (IEC) –10 to +45 °C +14 to +113 °F (No dew condensation), Storage: –20 to +60 °C –4 to +140 °F (No dew condensation) Accessory Detecting rotating direction of fan 6DPSOLQJUDWHȝV Average number of VDPSOHV Measuring distance L (mm in) Red LED 5.5 digit display Protection Material Diffuse reflection type Horizontal positioning 0.4 10° 0° í10° Green LED (lights up during laser emission) Alarm Ambient temperature 9HUWLFDOSRVLWLRQLQJ HL-G105A-R□ Incorporated (automatic restoration) Digital display Measuring the eccentricity of a metal shaft • Maximum source current : 50 mA • Residual voltage : 2.8 V or less (at 50 mA of source current) HL-G103A-R□ Diffuse reflection type í Judgment output or alarm output (setting selectable) NPN transistor, open-collector / PNP transistor, open-collector (selectable) Specular reflection type HL-G125□  Current Diffuse reflection type L Measuring object 0.4 Output range: 0 to 10.5 V (normal) / 11 V (at alarm), Output impedance: 100 Ω Timing input Detecting presence of O-ring 0.2 × 0.2 mm 0.008 × 0.008 in Voltage Output polarity setting input L 100 mA max. Short circuit protection Positioning of wafer í Sensor head Measuring object 24 V DC ±10 % including ripple 0.5 V (P-P) Output operation Inspecting processed food quantities 0.1 × 0.1 mm 0.004 × 0.004 in CMOS image sensor Current consumption Output (OUT 1, OUT 2, OUT 3) + ±0.08 % F.S. / °C Receiving element Analog output + Sensor head ±0.2 % F.S. Red semiconductor laser, Class 2 (Class 1 for specular reflection type) (IEC / JIS / FDA, Laser Notice No. 50) Max. output: 1 mW (0.39mW for specular reflection type) Peak emission wavelength: 655 nm 0.026 mil Supply voltage Diffuse reflection type í White ceramic Horizontal orientation Error (% F.S.) Measurement range: 30 ±4 mm 1.181 ±0.157 in 0.5 μm 0.020 mil Resolution: Linearity: ±0.1 % F.S. Beam diameter: 0.1 × 0.1 mm 0.004 × 0.004 in Measurement center distance White ceramic Vertical orientation Error (% F.S.) HL-G103A□ High function type HL-G103-S-J HL-G105-S-J HL-G108-S-J HL-G112-S-J HL-G125-S-J HL-G103A-RS-J HL-G105A-RS-J HL-G108A-RS-J Error (% F.S.) HL-G103□ Correlation between measuring distance and error characteristics Standard type HL-G103-A-C5 HL-G105-A-C5 HL-G108-A-C5 HL-G112-A-C5 HL-G125-A-C5 HL-G103A-RA-C5 HL-G105A-RA-C5 HL-G108A-RA-C5 Error (% F.S.) Specular reflection type Specular reflection type Error (% F.S.) Item Diffuse reflection type Error (% F.S.) Model No. Type For sensing characteristics diagrams for the diffuse reflection type (other than the HL-G125□), refer to the HL-G1 catalog or our website. SENSING CHARACTERISTICS (TYPICAL) Error (% F.S.) A total of 8 models accommodate a variety of applications Diffuse reflection type For more information about I/O circuit diagrams and communication specifications of the high-function type, refer to the HL-G1 catalog or our website. SPECIFICATIONS Error (% F.S.) Extensive selection Appearance Model No. Description HL-G1CCJ2 Length: 2 m 6.562 ft, Weight: 130 g approx. HL-G1CCJ5 Length: 5 m 16.404 ft, Weight: 320 g approx. HL-G1CCJ10 Length: 10 m 32.808 ft, Weight: 630 g approx. HL-G1CCJ20 Length: 20 m 65.617 ft, Weight: 1300 g approx. 14-core cabtyre cable with connector on both ends PRECAUTIONS FOR PROPER USE • This product has been developed / produced for industrial use. • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. • Do not operate products using methods other than the ones described in the instruction manual included with each product. Control or adjustment through procedures other than the ones specified may cause hazardous laser radiation exposure. • The following label is attached to the product. Handle the product according to the instruction given on the warning label. The Japanes, English, Chinese, Korean warning label is packed with the sensor. ( ) • This product is classified as a Class 2 (specular reflection type: Class 1) Laser Product under IEC / JIS standards and FDA regulations. Do not look at the laser beam directly or through an optical system such as a lens. (A Class 2 label is shown above.) A variety of high-end functions are included in a compact, self-contained body for exceptional ease of use Easy input settings while looking at digital display The built-in digital display makes it easy to perform sensor setting while checking displacement values. 5.5 digit, 7-segment LED display UP key HL-G125-A-C5 HL-G125-S-J Easy to embed in machines and production lines thanks to a built-in controller 20.4 0.803 2-ø 4.5 ø 0.177 51.4 2.024 60 2.362 Beam-receiving axis 47.5 1.870 57 2.244 49.4 1.945 70 47.5 1.8 ft ø6.85 ø0.270 0.5 m 15° Equipped on HL-G125-S-J only ø12.5 ø0.492 4 1. 3 1.6 693 40 ft Specular reflection type Equipped on HL-G103A-RS-J only Lightweight body that can be installed on movable parts Its lightweight resin body weighs 70 g approx., which can be installed on moving parts such as sliders and robot arms. Cable with superior flexibility is fitted as standard. Height: 60 mm 2.362 in Ideal for measuring mirrored objects 62.4 2.457 33 1.299 0 64 1. ø12.5 ø0.492 43 93 6 1. HL-G1 2-ø 4.5 ø 0.177 72.3 2.846 Beamreceiving axis m Amplifier separated type sensor Depth: 57 mm 2.244 in Diffuse reflection type 66.6 2.622 34.41 1.355 Flexible cable HL-G105A-RA-C5 HL-G105A-RS-J 5.5 digit LED display (Red) Alarm indicator (Orange) Laser emission indicator (Green) 20.4 0.803 64.2 2.528 39.32 1.548 Software tool for sensor configuration and evaluation In addition to configuring up to 16 sensors at once, this free tool makes it easy to gather data needed for analysis, such as received light waveform monitoring and data buffering. The interface language can be selected at the time of installation. ● Data buffering Stores and displays measurement data, which can be superimposed on previously recorded data for easy comparison and analysis. ● Received light waveform display Displays the amount of light received by cell from light-receiving element. ● Measured value display Displays measured values as well as the output state for each terminal. HMI screen data for sensor setting and data indication The GT02 / GT12 series HMI can be used in combination with the HL-G1 to allow easy confirmation of sensor status and configuration of sensor settings from a remote location. Japanese, English, Chinese, and Korean are supported. For more information about the GT series, visit our website or refer to our catalog. Select from the following HMI operator panels: Power supply: 24 V Communication port: RS422 (RS485) ● AIG02GQ14D ● AIG02MQ15D ● AIG12GQ14D / AIG12GQ15D ● AIG12MQ14D / AIG12MQ15D 66.8 2.630 Beamreceiving axis 7.53° ø12.5 ø0.492 ø6.85 ø0.270 0. 5 m 4 1. 1.6 3 64 93 0 ft ø12.5 ø0.492 L Model No. L HL-G1CCJ2 2,000 +2000 78.740 +7.8740 5,000 +5000 196.850 +19.6850 10,000 +1,0000 393.701 +39.3700 20,000 +2,0000 787.402 +78.7400 2013.12 31.2 1.228 Equipped on HL-G108A-RS-J only Extension cable HL-G1CCJ10 66.8 2.630 57.4 2.260 Extension cable (optional) (43 1.693) ø 12.5 ø 0.492 panasonic.net/id/pidsx/global ø 6.85 ø 0.270 cable 14-core × 0.1 mm2 Insulator diameter: ø 0.7 mm ø 0.028 in (RS-422/485 communication cable: ø 1.0 mm ø 0.039 in) (50 1.969) Panasonic Industrial Devices SUNX Co., Ltd. Global Sales Department Sensor configuration and evaluation software tool, HMI screen data, function blocks, etc. Terms of use Panasonic Industrial Devices SUNX offers no warranty for this software and is not liable for any loss or damage suffered as a result of its use or operation, whether direct, indirect, incidental, consequential, or unforeseen. ø6.85 ø0.270 0.5 4 m 1.6 1.693 3 40 ft 2-ø 4.5 ø 0.177 15.05° HL-G1CCJ□ HL-G1CCJ20 Software is available for download. Beam-emitting axis Equipped on HL-G105A-RS-J only HL-G1CCJ5 62.3 2.453 42.24 1.663 47.5 1.870 10.39° OUT 1 indicator (Yellow) OUT 2 indicator (Yellow) OUT 3 indicator (Yellow) UP key DOWN key Measurement center distance 82.9 3.264 10.75 0.423 20.4 0.803 69 2.717 59.5 2.343 32.8 1.291 69 2.717 Sensor head ENTER key 2-ø 4.5 ø 0.177 20.77° Beamreceiving axis 5.5 digit LED display (Red) Alarm indicator (Orange) Laser emission indicator (Green) UP key DOWN key 47.5 1.870 Thanks to its IP67 protective enclosure, the HL-G1 can be used in the presence of water and dust. Mounting holes are lined with metal sleeves, allowing the instrument to be tightened securely in place with up to 0.8 N·m of torque. Measurement center distance 47.3 1.862 13.4 0.528 Beam-emitting axis HL-G108A-RA-C5 HL-G108A-RS-J OUT 1 indicator (Yellow) OUT 2 indicator (Yellow) OUT 3 indicator (Yellow) ENTER key IP67 protective enclosure protects from water and dust Sensor head No.CE-HLG1A-4 December, 2013 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Telephone: +81-568-33-7861 Facsimile: +81-568-33-8591 All Rights Reserved ©Panasonic Industrial Devices SUNX Co., Ltd. 2013 Ŷ Laser Displacement Sensor Diffuse reflection type HL-G125Ƒ Specular reflection type HL-G10ƑAƑ Measure distances as long as 250mm 30° 4.3 ø 6.85 ø 0.270 0.169 Width: 20.4 mm 0.803 in New models UP key DOWN key Measurement center distance 26.3 1.035 17.5 0.689 Beamemitting axis 72.3 2.846 5 0. DOWN key Sensor head OUT 1 indicator (Yellow) OUT 2 indicator (Yellow) OUT 3 indicator (Yellow) ENTER key UP key DOWN key Measurement center distance 250 9.843 3.8 Beam0.150 emitting axis 6.2° 20.4 0.803 HL-G103A-RA-C5 HL-G103A-RS-J 5.5 digit LED display (Red) Alarm indicator (Orange) Laser emission indicator (Green) OUT 1 indicator (Yellow) OUT 2 indicator (Yellow) OUT 3 indicator (Yellow) ENTER key Controller installation and mounting space is not required because controller function is included in sensor unit. ENTER key Sensor head 5.5 digit LED display (Red) Alarm indicator (Orange) Laser emission indicator (Green) Compact For dimensions of the diffuse reflection type (other than the HL-G125□), refer to the HL-G1 catalog or our website. CAD data for dimensional diagrams can be downloaded from our website. DIMENSIONS (Unit: mm in) Ŷ 2013.12 panasonic.net/id/pidsx/global Conforming to EMC Directive Conforming to FDA regulations A variety of high-end functions are included in a compact, self-contained body for exceptional ease of use Easy input settings while looking at digital display The built-in digital display makes it easy to perform sensor setting while checking displacement values. 5.5 digit, 7-segment LED display UP key HL-G125-A-C5 HL-G125-S-J Easy to embed in machines and production lines thanks to a built-in controller 20.4 0.803 2-ø 4.5 ø 0.177 51.4 2.024 60 2.362 Beam-receiving axis 47.5 1.870 57 2.244 49.4 1.945 70 47.5 1.8 ft ø6.85 ø0.270 0.5 m 15° Equipped on HL-G125-S-J only ø12.5 ø0.492 4 1. 3 1.6 693 40 ft Specular reflection type Equipped on HL-G103A-RS-J only Lightweight body that can be installed on movable parts Its lightweight resin body weighs 70 g approx., which can be installed on moving parts such as sliders and robot arms. Cable with superior flexibility is fitted as standard. Height: 60 mm 2.362 in Ideal for measuring mirrored objects 62.4 2.457 33 1.299 0 64 1. ø12.5 ø0.492 43 93 6 1. HL-G1 2-ø 4.5 ø 0.177 72.3 2.846 Beamreceiving axis m Amplifier separated type sensor Depth: 57 mm 2.244 in Diffuse reflection type 66.6 2.622 34.41 1.355 Flexible cable HL-G105A-RA-C5 HL-G105A-RS-J 5.5 digit LED display (Red) Alarm indicator (Orange) Laser emission indicator (Green) 20.4 0.803 64.2 2.528 39.32 1.548 Software tool for sensor configuration and evaluation In addition to configuring up to 16 sensors at once, this free tool makes it easy to gather data needed for analysis, such as received light waveform monitoring and data buffering. The interface language can be selected at the time of installation. ● Data buffering Stores and displays measurement data, which can be superimposed on previously recorded data for easy comparison and analysis. ● Received light waveform display Displays the amount of light received by cell from light-receiving element. ● Measured value display Displays measured values as well as the output state for each terminal. HMI screen data for sensor setting and data indication The GT02 / GT12 series HMI can be used in combination with the HL-G1 to allow easy confirmation of sensor status and configuration of sensor settings from a remote location. Japanese, English, Chinese, and Korean are supported. For more information about the GT series, visit our website or refer to our catalog. Select from the following HMI operator panels: Power supply: 24 V Communication port: RS422 (RS485) ● AIG02GQ14D ● AIG02MQ15D ● AIG12GQ14D / AIG12GQ15D ● AIG12MQ14D / AIG12MQ15D 66.8 2.630 Beamreceiving axis 7.53° ø12.5 ø0.492 ø6.85 ø0.270 0. 5 m 4 1. 1.6 3 64 93 0 ft ø12.5 ø0.492 L Model No. L HL-G1CCJ2 2,000 +2000 78.740 +7.8740 5,000 +5000 196.850 +19.6850 10,000 +1,0000 393.701 +39.3700 20,000 +2,0000 787.402 +78.7400 2013.12 31.2 1.228 Equipped on HL-G108A-RS-J only Extension cable HL-G1CCJ10 66.8 2.630 57.4 2.260 Extension cable (optional) (43 1.693) ø 12.5 ø 0.492 panasonic.net/id/pidsx/global ø 6.85 ø 0.270 cable 14-core × 0.1 mm2 Insulator diameter: ø 0.7 mm ø 0.028 in (RS-422/485 communication cable: ø 1.0 mm ø 0.039 in) (50 1.969) Panasonic Industrial Devices SUNX Co., Ltd. Global Sales Department Sensor configuration and evaluation software tool, HMI screen data, function blocks, etc. Terms of use Panasonic Industrial Devices SUNX offers no warranty for this software and is not liable for any loss or damage suffered as a result of its use or operation, whether direct, indirect, incidental, consequential, or unforeseen. ø6.85 ø0.270 0.5 4 m 1.6 1.693 3 40 ft 2-ø 4.5 ø 0.177 15.05° HL-G1CCJ□ HL-G1CCJ20 Software is available for download. Beam-emitting axis Equipped on HL-G105A-RS-J only HL-G1CCJ5 62.3 2.453 42.24 1.663 47.5 1.870 10.39° OUT 1 indicator (Yellow) OUT 2 indicator (Yellow) OUT 3 indicator (Yellow) UP key DOWN key Measurement center distance 82.9 3.264 10.75 0.423 20.4 0.803 69 2.717 59.5 2.343 32.8 1.291 69 2.717 Sensor head ENTER key 2-ø 4.5 ø 0.177 20.77° Beamreceiving axis 5.5 digit LED display (Red) Alarm indicator (Orange) Laser emission indicator (Green) UP key DOWN key 47.5 1.870 Thanks to its IP67 protective enclosure, the HL-G1 can be used in the presence of water and dust. Mounting holes are lined with metal sleeves, allowing the instrument to be tightened securely in place with up to 0.8 N·m of torque. Measurement center distance 47.3 1.862 13.4 0.528 Beam-emitting axis HL-G108A-RA-C5 HL-G108A-RS-J OUT 1 indicator (Yellow) OUT 2 indicator (Yellow) OUT 3 indicator (Yellow) ENTER key IP67 protective enclosure protects from water and dust Sensor head No.CE-HLG1A-4 December, 2013 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Telephone: +81-568-33-7861 Facsimile: +81-568-33-8591 All Rights Reserved ©Panasonic Industrial Devices SUNX Co., Ltd. 2013 Ŷ Laser Displacement Sensor Diffuse reflection type HL-G125Ƒ Specular reflection type HL-G10ƑAƑ Measure distances as long as 250mm 30° 4.3 ø 6.85 ø 0.270 0.169 Width: 20.4 mm 0.803 in New models UP key DOWN key Measurement center distance 26.3 1.035 17.5 0.689 Beamemitting axis 72.3 2.846 5 0. DOWN key Sensor head OUT 1 indicator (Yellow) OUT 2 indicator (Yellow) OUT 3 indicator (Yellow) ENTER key UP key DOWN key Measurement center distance 250 9.843 3.8 Beam0.150 emitting axis 6.2° 20.4 0.803 HL-G103A-RA-C5 HL-G103A-RS-J 5.5 digit LED display (Red) Alarm indicator (Orange) Laser emission indicator (Green) OUT 1 indicator (Yellow) OUT 2 indicator (Yellow) OUT 3 indicator (Yellow) ENTER key Controller installation and mounting space is not required because controller function is included in sensor unit. ENTER key Sensor head 5.5 digit LED display (Red) Alarm indicator (Orange) Laser emission indicator (Green) Compact For dimensions of the diffuse reflection type (other than the HL-G125□), refer to the HL-G1 catalog or our website. CAD data for dimensional diagrams can be downloaded from our website. DIMENSIONS (Unit: mm in) Ŷ 2013.12 panasonic.net/id/pidsx/global Conforming to EMC Directive Conforming to FDA regulations
HL-G112-A-C5 价格&库存

很抱歉,暂时无法提供与“HL-G112-A-C5”相匹配的价格&库存,您可以联系我们找货

免费人工找货