HL
15A (1C), 10 A (2C)
SPACE SAVING
POWER RELAY
20.8
.819
HL RELAYS
FEATURES
27.2
1.071
• High switching capacity in a compact size
1 Form C (15 A 125 V AC), 2 Form C (10 A 250 V AC)
• Rugged construction for tough applications
• Long life
Mechanical: Min. 108 operations (DC),
Min. 5 × 107 operations (AC)
Electrical: Min. 5 × 105 operations
35.4
1.394
mm inch
SPECIFICATIONS
Contacts
Characteristics (at 25°C 77°F, 50% Relative humidity)
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Nominal switching
capacity
Max. switching power
Rating
(resistive)
Max. switching voltage
Max. switching current
Min. switching capacity#1
Expected
life
Mechanical (at 180 cpm)
15 A 125 V
AC
Electrical
10 A 250 V
(resistive)
AC
3 A 30 V DC
1 Form C
2 Form C
Max. operating speed
Initial insulation resistance*1
50 mΩ
Silver alloy
15 A 125 V AC,
10 A 250 V AC
10 A 250 V AC
AC: 2,500 VA
AC: 2,500 VA
DC: 90 W
DC: 90 W
250 V AC
250 V AC
30 V DC
30 V DC
15 A
10 A
100 mA, 5 V DC
5×107 (AC), 106 (DC)
5×105
—
5×105
5×105
5×10
5×10
Initial
breakdown
voltage*2
20 cpm
Between contact sets
Between open contacts
Between contacts and coil
Operate time (at nominal voltage)
Release time*3 (without diode)
(at nominal voltage)
Temperature rise, max.
(at nominal voltage)
Functional*4
Shock resistance
Destructive*5
Functional*6
Vibration resistance
5
Destructive
5
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as “Initial breakdown voltage” section
*2 Detection current: 10 mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
*7 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
TYPICAL APPLICATIONS
Min. 100 MΩ (at 500 V DC)
1,500 Vrms for 1 min.
1,000 Vrms for 1 min.
2,000 Vrms for 1 min.
Max. 25 ms (DC type)
Max. 25 ms (AC type)
Max. 25 ms (DC type)
Max. 25 ms (AC type)
Max. 80°C
Min. 196 m/s2 {20 G}
Min. 980 m/s2 {100 G}
10 to 55 Hz
at double amplitude of 1 mm
10 to 55 Hz
at double amplitude of 2 mm
Conditions for operation, Ambient
transport and storage*7 temperature
(Not freezing and
condensing at low
Humidity
temperature)
Unit weight
–50°C to +70°C
–58°F to +158°F
5 to 85% R.H.
Approx. 35 g 1.25 oz
ORDERING INFORMATION
Power station control equipment,
refrigerators, building control equipment,
office machines, and medical equipment.
Ex. HL
Contact arrangement
1: 1 Form C
2: 2 Form C
2
H
AC240V
Terminal arrangement
H: Plug-in
HP: PC board
HTM: Top mounting
L: Light emitting diode wired, plug-in
PL: Light emitting diode wired, PC board
Note: Standard packing Carton: 20 pcs., Case: 200 pcs.
UL/CSA approved type is standard.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Coil voltage
AC 6, 12, 24, 48,
120, 240 V
DC 6, 12, 24, 48,
110 V
HL
COIL DATA (at 20° C 68°F)
DC coils
Coil voltage,
V DC
Pick-up voltage,
V DC (max.)
Drop-out voltage,
V DC (min.)
Max. allowable
voltage, V DC
Coil resistance,
Ω (±10%)
Nominal coil
current, mA
6
12
24
48
110
4.8
9.6
19.2
38.4
88.0
0.6
1.2
2.4
4.8
11.0
6.6
13.2
26.4
52.8
121.0
40
160
650
2,600
10,000
150
75
37
18.5
10
Operating power, W
Nominal
Minimum
0.90
0.58
1.0
0.64
AC coils at 60 Hz
Coil voltage,
V DC
Pick-up voltage,
V AC (max.)
Drop-out voltage,
V AC (min.)
Max. allowable
voltage, V AC
Nominal coil
current, mA
6
12
24
48
110/120
220/240
4.8
9.6
19.2
38.4
88
176
1.8
3.6
7.2
14.4
36
72
6.6
13.2
26.4
52.8
132
264
200
100
50
25
10.9/11.9
6.0/6.5
Notes:
1. The range of coil current is ±15% for AC (60 Hz), ±10% for DC, at 20°C.
2. The relay may be used in the range of 80% to 110% of the nominal coil
voltage. However, it is recommended that the relay be used at 85% to
110% nominal voltage to take temporary voltage variations into
consideration.
3. Each coil resistance of DC types is the measured value at a coil
temperature of 20°C. Please allow a compensation of ±0.4%
resistance for each coil temperature change of ±1°C.
Operating power, VA
Nominal
Minimum
1.20
0.77
4. All AC 240 V types are rated for double coil voltages, both AC 220 V
and AC 240 V.
5. For use with 220 or 240 V DC, connect a resistor, as suggested below,
in series with the 110 V DC relay.
Voltage
220 V DC
240 V DC
1 Form C, 2 Form C
11 kW (5 W)
13 kW (5 W)
DIMENSIONS
mm inch
Plug-in
PC board*1
20.8
.819
Top mounting
20.8
.819
27.2
1.071
27.2
1.071
35.4
1.394
35.4
1.394
6.35
.250
Accepts Faston #187
HL1
(1 Form C)
3.95
.156
4.6
.181
6
.236
7.15
.281
Schematic
2
3
6
7
14.2
.559
3.5
.138
1.5
.059
6
AC type
DC type
8
(+)
2
6
2
2
3
3
(−)
6
6
7
(∼)
8
(∼)
AC type
Mounting dimension
2-3.2 to 3.5 dia
2-.126 to .138 dia
37.6
1.480
3
7
6
7
Accepts Faston #187
3.6
.142
37.6
1.480
8
7
8
3
6
8
(∼)
1.5
.059
Schematic
2
3
6
2
2
3
7
(∼)
6.35
.250
0.5
.020
2
7
1.2
.047
5
.197
3
8
43
1.693
35.4
1.354
1.2
.047
1.2
.047
10
.394
2
.079
20.6
.811
7
(−)
8
(+)
DC type
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
8
Schematic
2
3
6
7
8
HL
mm inch
Plug-in
PC board*1
27.2
1.071
20.8
.819
Top mounting
27.2
1.071
20.8
.819
1.2
.047
1.2
.047
1.2
.047
5
.197
6.35
.250
6.35
.250
3.5
.138
1.5
.059
Accepts Faston #187
10
.394
0.5
.020
1.5
.059
Accepts Faston #187
3.6
.142
3.7
.146
4.7
.185
6
.236
7.3
.287
Schematic
1 2
3 4
5 6
7
8
14.2
.559
1
3
5
7
Schematic
1 2
3 4
5 6
7
8
2
4
6
8
2
2
7
(∼)
7
8
(∼)
AC type
7
(∼)
DC type
37.6
1.480
Schematic
1 2
3 4
5 6
8
7
8
6
6
8
(+)
(−)
7
2
4
6
Mounting dimension
2-3.2 to 3.5 dia.
2-.126 to .138 dia.
37.6
1.480
3
3
6
6
1
3
5
2
2
3
3
43
1.693
34.4
1.354
35.4
1.394
35.4
1.394
HL2
(2 Form C)
2
.079
20.6
.811
7
8
(∼)
8
(+)
(−)
AC type
DC type
Tolerance: ±0.5 ±.020
*1 PC board pattern
Copper-side view
10
.394
4.6
.181
5-2 dia.
5-.079 dia.
R3
1.25 2
17.75 .049 .079
.700 1.25 2
.049 .079
7.15 8.5
4
.281 .335
.158
6
.236
R2
4
.158
8-2 dia.
8-.079 dia.
10
.394
1.25
.049
18
13.3 .709
.524
7.3
4
.158 .287
R2
R2
14.2
.559
14.2
.559
(HL2)
(HL1)
Tolerance: ±0.1 ±.004
ACCESSORIES
mm inch
HL1-SS-K (with hold-down clip)
HL2-SS-K (with hold-down clip)
25.5
1.004
Plug-in terminal socket mount
Simply insert socket into panel hole and
push down as indicated to lock socket in
place.
25.5
1.004
Accepts Faston #187
Accepts Faston #187
0.23
.009
29.4
1.157
4.75
.187
0.23
.009
29.4
1.157
4.75
.187
1.0 to 2.0
.039 to .079
11.2 .441
18.7
.736
11.2 .441
18.7
.736
Panel cutout
Panel cutout
25.8
1.016
21.6
.850
Panel thickness
Panel cutout for tandem mounting
25.8
1.016
25.8
1.016
8.9
.350
21.6
.850
25.8
1.016
21.6
.850
5.9
.232
Minimum
separation distance
21.6
.850
Tolerance: ±0.1 ±.004
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
HL
2. PC board terminal socket
HL1-PS-K
mm inch
HL2-PS-K
Layout for tandem mounting
(2 Form C)
10
.394
21.2
.835
23.2
.913
10
.394
21.2
.835
0.23
.009
17.45
.687
0.23
.009
29.4
1.157
(6.6)
(.260)
29.4
1.157
2.0
.079
2.0
.079
1.0
.039
11.2
.441
16.2
.638
11.2
.441
16.2
.638
PC board pattern
17.45
.687
8-2.4 dia.
8-.094 dia.
17.45
.687
12.75
.502
15.3
.602
1.0
.039
PC board pattern
5-2.4 dia.
5-.094 dia.
10
.394
17.25
.679
(5.3)
(.209)
15.3
.602
7.9
.311
15.3
.602
2.4 dia.
.094 dia.
17.45
.687
12.75
.502
6.75
.266
10
.394
15.3
.602
6.75
.266
Tolerance: ±0.1 ±.004
3. Screw terminal socket for DIN rail assembly
HL2-SFD-K (with hold-down clip)
9.35±0.2
.368±.008
Schematic
15.3±0.2
.602±.008
M3.5
Terminal screw
2
10±0.2
.394±.008
2
1
4
3
21.1±0.6
.831±.024
4
Layout for tandem mounting
1
26
1.024
3
8
.315
26
1.024
4.65±0.2
.183±.008
67
2.638
33.5
1.319
67±1
2.638±.039
1.35±0.1
.053±.004
8.1±0.2
.319±.008
6
5
8
7
26±0.6
1.024±.024
30±0.6
1.181±.024
8
.315
6
5
8
7
30
1.181
4
.158
30
1.181
2-M3.5 SCREW HOLES OR
2-4.2 ±0.1 DIA.
Minimum separation in tandem mounting
28.6±0.6
1.126±.024
Tolerance: ±0.1 ±.004
10±0.3
.394±.012
(Remark) Max. continuous current of all HL sockets is 10 A.
For Cautions for Use, see Relay Technical Information