VDE
JE-X
RELAYS
COMPACT ECONOMICAL
POWER RELAYS
22
.866
FEATURES
14
.551
• Compact size - Height Max. 18.7 mm .736 inch
lower than JY relay (22.5 mm) (.886 inch)
• High contact capacity — 5A 125 V AC
• Safety-oriented between coil and contact terminals
• All plastic materials: UL flame retardance 94V-0
• VDE, TÜV also approved
18.7
.736
mm inch
TERMINAL LAYOUT
Distance of 9.16 mm .360 inch between common and coil terminals and 8.9 mm .350 inch between contacts give room to the
land diameter width when the relay is mounted on PC board, and
allow design of patterns with insulation distances of 6 mm .236
inch between common and coil and 5.9 mm .232 inch between
contacts.
• 3 mm .118 inch or more insulation distance for close
mounting can be kept easily with JE-X relays.
0.9
.035
R1
3 dia.
.118 dia.
Coil
9.16
.361
6.16
.243
8.9
.350
3 dia.
.118 dia.
N.O.
4.45
3 dia.
.175
.118 dia. 5.9
.233 4.45
N.C.
COM
.175
In case of 3 mm
.118 inch land
diameter
N.C.
R2
3
.118
N.O.
8.9
.350
N.C.
N.O.
1.3 dia.
.051 dia.
Coil
mm inch
mm inch
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Contact material
Nominal switching
capacity
Rating
Max. switching power
(resistive
load)
Max. switching voltage
Max. switching current
Mechanical (at 180 cpm)
Expected
life (min.
Electrical (at 20 cpm)
operations) (at rated load)
Characteristics
1 Form A
1 Form C
100 mΩ
Silver alloy
5 A 30 V DC, 5 A 125 V AC,
3A 250 V AC
750 VA, 150 W
250 V AC, 30 V DC
5A
5×106
105
Max. operating speed
Initial insulation resistance*1
Between open contacts
Between contacts and
coil
Surge voltage between coil
and contact*3
Operate time*4 (at nominal voltage)
Release time (without diode)*4
(at nominal voltage)
Initial
breakdown
voltage*2
Temperature rise (at 70°C)
Coil
Minimum operating power
Nominal operating power
196 mW
400 mW
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section
*2 Detection current: 10 mA
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time
*5 Half-wave pulse of sine wave: 6ms; detection time: 10µs
*6 Half-wave pulse of sine wave: 6ms
*7 Detection time: 10µs
*8 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT.
Shock resistance
Functional*5
Destructive*6
Functional*7
Vibration resistance
Destructive
Conditions for operation,
Ambient
transport and storage*8
temp.
(Not freezing and condensHumidity
ing at low temperature)
Unit weight
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
20 cpm (at 70°C)
Min. 100 MΩ (at 500 V DC)
750 Vrms
1,500 Vrms
Min. 5,000 V
Approx. 10 ms
Approx. 2 ms
Max. 45°C with nominal coil
voltage and at nominal
switching capacity
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
98 m/s2 {10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2.0 mm
–40°C to +70°C
–40°F to +158°F
5 to 85% R.H.
Approx. 9.2g .32 oz
JE-X
TYPICAL
APPLICATIONS
ORDERING INFORMATION
Ex. JE
• Home appliances
Oven, range, dryer, heater,
Air conditioner etc.
• Automotive
• Garage door opener
• Personal computer
• Programmable controller
1
X
N
DC12V
Contact arrangement
Pick-up voltage
1a: 1 Form A
1:1 Form C
N:70% of nominal voltage
H
Protective
construction
Coil voltage
DC 5, 6, 9, H: Flux-resistant type
12, 24, 48 V
(Note) Standard packing: Carton 100 pcs. Case 500 pcs.
UL/CSA, VDE approved type is standard.
TYPES
Contact arrangement
Pick-up 70% V type
Flux-resistant type
JE1aXN-DC5V-H
JE1aXN-DC6V-H
JE1aXN-DC9V-H
JE1aXN-DC12V-H
JE1aXN-DC24V-H
JE1aXN-DC48V-H
JE1XN-DC5V-H
JE1XN-DC6V-H
JE1XN-DC9V-H
JE1XN-DC12V-H
JE1XN-DC24V-H
JE1XN-DC48V-H
Coil voltage
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
48 V DC
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
48 V DC
1 Form A
1 Form C
COIL DATA (at 20°C 68°F)
Nominal voltage,
V DC
Pick-up voltage,
V DC (max.)
Drop-out voltage,
V DC (min.)
5
6
9
12
24
48
3.5
4.2
6.3
8.4
16.8
33.6
0.5
0.6
0.9
1.2
2.4
4.8
Nominal operating
currrent,
mA (±10%)
80
67
44
33
17
8.3
Nominal operating
power,
mW
400
400
400
400
400
400
Coil resistance,
Ω(±10%)
62.5
90
202
360
1,440
5,760
Maximum
allowable voltage,
V DC (at 70°C)
6.5
7.8
11.7
15.6
31.2
62.4
DIMENSIONS
mm inch
PC board pattern (Bottom view)
14
.551
5-1.3 dia.
5-.051 dia.
22
.866
7.62
.300
4.45
.175
4.45
.175
10.16
.400
Tolerance: ±0.1 ±.004
Max.
18.2
.717
Schematic (Bottom view)
0.5
.020
3.9
.154
0.8
.031
3.9
.154
1
10.16
.400
0.3
.012
7.62
.300
COM
3
2
1.1
.043
0.4
.016
7.62
.300
1
COM
3
0.8
.031
7.62
.300
N.O.
4
1.2
.047
N.C.
5
2
4.45
.175
4.45
.175
N.O.
4
5
N.C.
Note: The above shows 1 Form C type, and No. 5
terminal is eliminated on the 1 Form A type.
Dimension:
Max. 1mm .039 inch:
1 to 5mm .039 to .197 inch:
Min. 5mm .197 inch:
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
General tolerance
±0.2 ±.008
±0.3 ±.012
±0.4 ±.016
JE-X
REFERENCE DATA
1. Max. switching power
3. Coil temperature rise (at 30°C 86°F)
2. Operate and release time
Operate & release time, ms
Contact current, A
3
AC resistive load
DC resistive
load
1
0.5
10
Operate time
Max.
Min.
5
Release time
30
50
100
0
200250
80
100
Voltage, V
50
40
30
20
120
100
100
30°C
40°C
60°C
50
Life, ×104
60
125V AC
resistive load
10
250V AC
resistive load
40
30
100
110
130
150
Coil applied voltage, %V
1
0
1
2
3
4
5
110
130
150
Coil applied voltage, %V
5. Life curve
70
5A
3A
1.5A
0A
60
Coil applied voltage, %V
4. Coil temperature rise
(Contact carrying current: 5 A)
Temperature rise, °C
Max.
Min.
Temperature rise, °C
15
5
6
Contact current, A
NOTE
Soldering should be carried out within 3 s
at 350°C 662°F or within 5 s at 250°C
482°F.
For Cautions for Use, see Relay Technical Information.