0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
JQ1A-B-18V-F

JQ1A-B-18V-F

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    Relay Coil

  • 数据手册
  • 价格&库存
JQ1A-B-18V-F 数据手册
JQ VDE 1a/1c 5A/10A small power relays RoHS compliant JQ RELAYS FEATURES TYPICAL APPLICATIONS • High electrical noise immunity • High switching capacity in a compact package • High sensitivity: 200 mW (1a), 400 mW (1c) • High surge voltage: 8,000 V between contacts and coil • UL, CSA, VDE, SEMKO approved and TÜV available • Class B coil insulation type also available. • Air conditioners • Refrigerators • Microwave ovens • Heaters ORDERING INFORMATION JQ F Contact arrangement 1a: 1 Form A 1 : 1 Form C Contact capacity Nil: Standard (5A) P: High capacity (10A) Coil insulation class Nil: Class E coil insulation B: Class B coil insulation (UL) Nominal coil voltage (DC) 5V, 6V, 9V, 12V, 18V, 24V, 48V* Contact material F: AgSnO2 type Certified by UL, CSA, VDE and SEMKO Note: *Available only for 1 Form C type TYPES 1) Standard type Standard type Nominal coil voltage 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC 1 Form A Part No. JQ1a-5V-F JQ1a-6V-F JQ1a-9V-F JQ1a-12V-F JQ1a-18V-F JQ1a-24V-F – High capacity type 1 Form C Part No. JQ1-5V-F JQ1-6V-F JQ1-9V-F JQ1-12V-F JQ1-18V-F JQ1-24V-F JQ1-48V-F 1 Form A Part No. JQ1aP-5V-F JQ1aP-6V-F JQ1aP-9V-F JQ1aP-12V-F JQ1aP-18V-F JQ1aP-24V-F – 1 Form C Part No. JQ1P-5V-F JQ1P-6V-F JQ1P-9V-F JQ1P-12V-F JQ1P-18V-F JQ1P-24V-F JQ1P-48V-F Standard packing: Carton 100 pcs., Case 500 pcs. Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB185E 201202-T JQ RATING 1. Coil data Contact Nominal coil arrangement voltage 5V DC 1 Form A 1 Form C 6V DC 9V DC 12V DC 18V DC 24V DC 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC Pick-up voltage (at 20°C 68°F) Standard type: 75%V or less of nominal voltage (Initial) High capacity type: 80%V or less of nominal voltage (Initial) Standard type: 75%V or less of nominal voltage (Initial) High capacity type: 80%V or less of nominal voltage (Initial) Drop-out voltage (at 20°C 68°F) Nominal operating current [±10%] (at 20°C 68°F) 5%V or more of nominal voltage (Initial) 40.0mA 33.3mA 22.2mA 16.7mA 11.1mA 8.3mA 125 180 405 720 1,620 2,880 5%V or more of nominal voltage (Initial) 80 mA 66.7mA 44.4mA 33.3mA 22.2mA 16.7mA 8.3mA 62.5Ω 90 Ω 202.5Ω 360 Ω 810 Ω 1,440 Ω 5,760 Ω Coil resistance [±10%] (at 20°C 68°F) Nominal operating power (at 20°C 68°F) Ω Ω Ω Ω Ω Ω Max. applied voltage 180% of nominal voltage (at 20°C 68°F) 200mW 130% of nominal voltage (at 70°C 158°F) [When using relays at 85°C 185°F, see Notes*4] 150% of nominal voltage (at 20°C 68°F) 400mW 110% of nominal voltage (at 70°C 158°F) [When using relays at 85°C 185°F, see Notes*4] 2. Specifications Characteristics Contact Item Arrangement Contact resistance (Initial) Contact material Nominal switching capacity (resistive load) Rating Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (reference value)*1 Insulation resistance (Initial) Breakdown voltage (Initial) Between open contacts Between contact and coil Temperature rise (coil) Electrical characteristics Surge breakdown voltage*2 (Between contact and coil) (Initial) Operate time (at nominal voltage) (at 20°C 68°F) (Initial) Release time (at nominal voltage) (at 20°C 68°F) (Initial) Functional Destructive Functional Vibration resistance Destructive Mechanical (at 180 times/min.) Shock resistance Mechanical characteristics Expected life Conditions Conditions for operation, transport and storage*3 Max. operating speed Unit weight Specifications Standard type High capacity type 1 Form C 1 Form A 1 Form C Max. 100mΩ (By voltage drop 6 V DC 1 A) AgSnO2 type N.O. side: N.O. side: 5 A 125 V AC, 10 A 125 V AC, 2 A 250 V AC, 5 A 250 V AC, 5 A 125 V AC, 10 A 125 V AC, 3 A 30 V AC 5 A 30 V AC 2 A 250 V AC, 5 A 250 V AC, N.C. side: N.C. side: 5 A 30 V DC 5 A 30 V DC 2 A 125 V AC, 3 A 125 V AC, 1 A 250 V AC, 2 A 250 V AC, 1 A 30 V DC 1 A 30 V DC N.O. side: N.O. side: 625 VA, 90 W 1,250 VA, 150 W 625 VA, 150 W 1,250 V AC, 150 W N.C. side: N.C. side: 250 VA, 30 W 500 V AC, 30 W 250 V AC, 110 V DC (0.3A) N.O.: 5 A, N.C.: 2 A N.O.: 10 A, N.C.: 3 A 200 mW 400 mW 200 mW 400 mW 100 mA, 5 V DC Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “Breakdown voltage” section. 1 Form A 1,000 Vrms for 1 min. 750 Vrms for 1 min. 1,000 Vrms for 1 min. 750 Vrms for 1 min. 4,000 Vrms for 1 min. (Detection current: 10 mA) Max. 45°C 113°F Max. 45°C 113°F (By resistive method, nominal coil voltage (By resistive method, nominal coil voltage applied to the coil; contact carrying current: applied to the coil; contact carrying current: 5A, at 70°C 158°F) 10A, at 70°C 158°F) 8,000 V Max. 20 ms (excluding contact bounce time.) Max. 10 ms (excluding contact bounce time) (Without diode) 294 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.) 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10µs.) 10 to 55 Hz at double amplitude of 2.0 mm Min. 107 Ambient temperature: –40°C to +70°C –40°F to +158°F (class E insulation), –40°C to +85°C –40°F to +185°F*4 (class B insulation) Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at nominal switching capacity) Approx. 7 g .25 oz * Specifications will vary with foreign standards certification ratings. Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. *4. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with 20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range. ASCTB185E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ JQ 3. Expected electrical life Type Switching capacity 5 A 125 V AC 3 A 125 V AC 2 A 250 V AC 5 A 30 V DC 5 A 125 V AC 3 A 125 V AC 2 A 250 V AC 3 A 30 V DC 2 A 125 V AC 1 A 250 V AC 1 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 3 A 125 V AC 2 A 250 V AC 1 A 30 V DC 1 Form A Standard type N.O. 1 Form C N.C. 1 Form A N.O. High capacity type 1 Form C N.C. No. of operations 5×104 2×105 2×105 105 5×104 2×105 2×105 105 2×105 2×105 105 5×104 5×104 105 5×104 5×104 105 2×105 2×105 105 REFERENCE DATA 1.-(1) Max. switching capacity (1 Form A type) 1.-(2) Max. switching capacity (1 Form C type) 100 Contact current, A Contact current, A 100 AC resistive load (High capacity type) 10 5 100 250 10 5 3 2 AC resistive load 1 (High capacity type) N.C. side AC resistive load (Standard type) N.C. side 1 AC resistive load (Standard type) 10 AC resistive load (High capacity type) N.O. side AC resistive load (Standard type) N.O. side 10 1,000 100 250 1,000 Contact voltage, V Contact voltage, V Standard type 2. Life curve 3.-(1) Operate & release time (1 Form A type) 3.-(2) Operate & release time (1 Form C type) Ambient temperature: room temperature Tested sample: JQ1a-12V-F, 25 pcs. Tested sample: JQ1-24V-F, 25 pcs. 125V AC resistive load 10 250V AC resistive load 8 6 Operate time 4 2 Release time 1 0 1 2 3 4 5 Contact current, A Panasonic Corporation 0 80 100 120 Max. Max. Min. Min. 8 6 Operate time 4 Max. Max. Min. Min. 2 Release time 150 Coil applied voltage, %V Automation Controls Business Unit Operate & release time, ms Operate & release time, ms Life, ×104 100 0 80 100 120 150 Coil applied voltage, %V industrial.panasonic.com/ac/e/ ASCTB185E 201202-T JQ 4.-(1) Coil temperature rise (1 Form A type) 4.-(2) Coil temperature rise (1 Form C type) Contact carrying current: 3 A, 5 A Measured portion: Inside the coil Contact carrying current: 3 A, 5 A Measured portion: Inside the coil 70 40 Temperature rise, °C Temperature rise, °C 50 5 A at 70°C 5 A at 85°C 30 20 3 A at 70°C 60 5 A at 70°C 50 3 A at 70°C 40 5 A at 85°C 30 3 A at 85°C 20 3 A at 85°C 10 10 0 0 100 110 120 130 140 150 160 170 180 190 100 110 120 Coil applied voltage, %V 130 140 150 160 Coil applied voltage, %V 5.-(1) Ambient temperature characteristics (1 Form A type) 5.-(2) Ambient temperature characteristics (1 Form C type) Tested sample: JQ1a-24V-F Contact carrying current: 3 A, 5 A Tested sample: JQ1-24V-F Contact carrying current: 3 A, 5 A 400 300 1 2 200 3 5 6 4 Coil applied voltage, %V Coil applied voltage, %V 400 100 300 1 2 200 3 4 5 100 6 7 0 20 30 40 50 60 70 80 0 90 20 30 7 40 Ambient temperature, °C 50 60 70 80 90 Ambient temperature, °C 1 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130°C 266°F) (Carrying current: 3 A) 2 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130°C 266°F) (Carrying current: 5 A) 3 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) (Carrying current: 3 A) 4 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) (Carrying current: 5 A) 5 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A) 6 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 3 A) 7 Pick-up voltage High capacity type 1. Life curve 2.-(1) Operate & release time (1 Form A type) 2.-(2) Operate & release time (1 Form C type) Ambient temperature: room temperature Tested sample: JQ1aP-12V-F, 25 pcs. Tested sample: JQ1P-12V-F, 25 pcs. 250V AC resistive load 1 0 2 4 8 6 Operate time 4 Max. Min. Max. Min. 2 6 8 0 10 Release time 80 100 Contact current, A 120 150 3.-(2) Coil temperature rise (1 Form C type) Contact carrying current: 5 A, 10 A Measured portion: Inside the coil 60 Operate time 4 Max. Max. Min. Min. 2 80 100 120 150 Coil applied voltage, %V Contact carrying current: 5 A, 10 A Measured portion: Inside the coil 60 6 Release time 3.-(1) Coil temperature rise (1 Form A type) 70 8 0 Coil applied voltage, %V 70 Operate & release time, ms 125V AC resistive load 10 Operate & release time, ms Life, ×104 100 10 A at 85°C 50 10 A at 70°C 40 5 A at 70°C 30 Temperature rise, °C Temperature rise, °C 10 A at 85°C 10 A at 70°C 50 5 A at 70°C 40 5 A at 85°C 30 5 A at 85°C 20 20 10 10 0 100 120 140 160 180 0 Coil applied voltage, %V ASCTB185E 201202-T Panasonic Corporation 100 110 120 130 140 150 160 Coil applied voltage, %V Automation Controls Business Unit industrial.panasonic.com/ac/e/ JQ 4.-(1) Ambient temperature characteristics (1 Form A type) 4.-(2) Ambient temperature characteristics (1 Form C type) Tested sample: JQ1aP-24V-F Contact carrying current: 5 A, 10 A Tested sample: JQ1P-24V-F Contact carrying current: 5 A, 10 A 400 1 Coil applied voltage, %V Coil applied voltage, %V 400 2 300 200 3 5 4 300 1 2 200 3 4 5 100 100 6 0 1 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130°C 266°F) (Carrying current: 5 A) 2 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130°C 266°F) (Carrying current: 10 A) 3 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) (Carrying current: 5 A) 4 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) (Carrying current: 10 A) 5 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 10 A) 6 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A) 7 Pick-up voltage 20 30 6 7 40 50 60 70 80 90 0 20 30 Ambient temperature, °C 7 40 50 60 70 80 90 Ambient temperature, °C DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ External dimensions CAD Data 1 Form A 1 Form A 10 .394 20 .787 Schematic (Bottom view) 1 Form C COM N.O. Coil COM N.O. Coil 15.6 .614 N.C. 0.4 .016 7.62 .300 4.2 .165 0.5 dia. .020 dia. 10.16 .400 0.3 .012 7.62 .300 0.3 .012 7.62 .300 0.8 .031 1 Form C 1 Form A 10 .394 20 .787 10.16 .400 15.6 .614 PC board pattern (Bottom view) 1FormC 7.62 .300 4-1.3 dia. 4-.051 dia. 7.62 .300 0.4 .016 7.62 .300 4.2 .165 0.5 dia. .020 dia. 7.62 .300 5-1.3 dia. 5-.051 dia. 7.62 .300 2.54 .100 10.16 .400 0.3 .012 5.08 .200 2.54 .100 0.3 .012 0.3 .012 Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 5mm .197 inch: Min. 5mm .197 inch: Panasonic Corporation 10.16 .400 7.62 .300 0.8 .031 Tolerance: ±0.1 ±.004 General tolerance ±0.2 ±.008 ±0.3 ±.012 ±0.4 ±.016 Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB185E 201202-T JQ SAFETY STANDARDS Item Standard type (5A) 1 Form A UL/C-UL (Recognized) File No. Contact rating E43028 5A 125V AC 5A 277V AC 5A 30V DC 0.3A 110V DC 1/10HP 125V AC 1/6HP 277V AC CSA (Certified) File No. Contact rating File No. LR26550 5A 125V AC 5A 277V AC 5A 30V DC 0.3A 110V DC 1/10HP 125V AC 1/6HP 277V AC 40011435 VDE (Certified) Contact rating 5A 250V AC (cosφ =0.4) TÜV (Certified) File No. Rating B 11 04 5A 250V AC (cosφ =0.4) 13461 296 5A 30V DC (0ms) SEMKO (Certified) File No. Contact rating 817138 3(2)A 125V AC 2(1)A 250V AC 5A 30V DC Standard type (5A) 1 Form C E43028 5A 125V AC 5A 277V AC 5A 30V DC 0.3A 110V DC 1/10HP 125V AC 1/6HP 277V AC LR26550 5A 125V AC 5A 277V AC 5A 30V DC 0.3A 110V DC 1/10HP 125V AC 1/6HP 277V AC 40011435 5A 250V AC (cosφ =0.4) (N.O.) 3A 250V AC (cosφ =0.4) (N.C.) B 11 04 5A 250V AC (cosφ =0.4) 13461 296 5A 30V DC (0ms) 817138 3(2)A 125V AC 2(1)A 250V AC 5A 30V DC High capacity type (10A) 1 Form A E43028 LR26550 10A 125V AC 8A 277V AC 5A 30V DC 0.3A 110V DC 1/6HP 125V AC 1/6HP 277V AC 40011435 10A 250V AC (cosφ =0.4) B 11 04 10A 250V AC (cosφ =0.4) 13461 296 5A 30V DC (0ms) 817138 5(3)A 250V AC 5A 30V DC High capacity type (10A) 1 Form C E43028 10A 125V AC 8A 277V AC 5A 30V DC 0.3A 110V DC 1/6HP 125V AC 1/6HP 277V AC 10A 125V AC 8A 277V AC 5A 30V DC 0.3A 110V DC 1/6HP 125V AC 1/6HP 277V AC LR26550 10A 125V AC 8A 277V AC 5A 30V DC 0.3A 110V DC 1/6HP 125V AC 1/6HP 277V AC 40011435 (N.O.) 10A 250V AC (cosφ =0.4) (N.C.) 3A 250V AC (cosφ =0.4) B 11 04 10A 250V AC (cosφ =0.4) 13461 296 5A 30V DC (0ms) 817138 5(3)A 250V AC 5A 30V DC NOTES Note about relay installation orientation Top When installing with the relay terminals parallel to the ground, the contact terminals at the bottom and the coil terminals at the top, component friction will occur after numerous switching actions or due to vibration in the non-excitation state. Since this may cause the relay to stop functioning when the pick-up voltage increases even if the nominal voltage is applied, please do not install using this orientation. Bottom For Cautions for Use. ASCTB185E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Panasonic: JQ1P-B-24V-F JQ1P-48V-F JQ1AP-B-24V-F JQ1-B-12V-F JQ1APE-24V-H12 JQ1A-5V JQ1A-5V-F JQ1AP-12V-F JQ1AP-24V-F JQ1AP-5V-F JQ1-5V-F JQ1A-12V-F JQ1P-5V-F JQ1-24V-F JQ1-12V-F JQ1P-12V-F JQ1P-24V-F JQ1A-24V-F JQ1-18V JQ1-18V-F JQ1-3V JQ1-48V JQ1-48V-F JQ1-6V JQ1-6V-F JQ1-9V JQ1-9V-F JQ1A18V JQ1A-18V-F JQ1A-3V JQ1A-6V JQ1A-6V-F JQ1A-9V JQ1A-9V-F JQ1A-B-12V JQ1A-B-12V-F JQ1A-B-18V JQ1A-B-18V-F JQ1A-B-24V JQ1A-B-24V-F JQ1A-B-5V JQ1A-B-5V-F JQ1A-B-6V JQ1A-B-6V-F JQ1A-B-9V JQ1A-B-9V-F JQ1A-F-24V JQ1AP-18V JQ1AP-18V-F JQ1AP-3V JQ1AP-6V JQ1AP-6V-F JQ1AP-9V JQ1AP-9V-F JQ1AP-B-12V-F JQ1AP-B-18V JQ1AP-B-18V-F JQ1AP-B-5V JQ1AP-B-5V-F JQ1AP-B-6V JQ1AP-B-6V-F JQ1AP-B-9V JQ1AP-B-9V-F JQ1AP-B-9V-Y3 JQ1AP-F-12V JQ1AP-F-12V-F JQ1APF-18V JQ1AP-F-24V-F JQ1APF-B-12V-F JQ1APF-F-12V JQ1APF-F-12V-F JQ1APF-F-24V-F JQ1APF-F-5V-F JQ1APF-F-9V-F JQ1-B-12V JQ1-B-18V JQ1-B-18V-F JQ1-B-24V JQ1-B-24V-F JQ1-B-48V JQ1-B-48V-F JQ1-B-5V JQ1-B-5V-F JQ1-B-6V JQ1-B-6V-F JQ1-B-9V JQ1-B-9V-F JQ1-F-24V JQ1P-18V-F JQ1P-3V JQ1P-48V JQ1P-6V-F JQ1P-9V JQ1P-9VF JQ1P-B-12V JQ1P-B-12V-F JQ1P-B-18V JQ1P-B-18V-F JQ1P-B-24V-Y3 JQ1P-B-48V
JQ1A-B-18V-F 价格&库存

很抱歉,暂时无法提供与“JQ1A-B-18V-F”相匹配的价格&库存,您可以联系我们找货

免费人工找货
JQ1A-B-18V-F
  •  国内价格 香港价格
  • 1+25.587971+3.17418
  • 10+23.9647410+2.97282
  • 25+21.3072025+2.64315
  • 50+20.2395050+2.51070

库存:55