JQ1P-5V

JQ1P-5V

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
JQ1P-5V 数据手册
Automation Controls Catalog Partly to Be Discontinued: 10A type (Made in Thailand) Last time buy: September 30, 2016 JQ RELAYS 1a/1c 5A/10A small power relays Protective construction:Sealed type FEATURES 20 • High electrical noise immunity • High switching capacity in a compact package • High sensitivity: 200 mW (1a), 400 mW (1c) • High surge voltage: 8,000 V between contacts and coil • UL, CSA, VDE, SEMKO approved and TÜV available • Class B coil insulation type also available. 10 16 TYPICAL APPLICATIONS • Air conditioners • Refrigerators • Microwave ovens • Heaters (Unit:mm) ORDERING INFORMATION JQ F Contact arrangement 1a:1 Form A 1 :1 Form C Contact capacity Coil insulation class Nominal coil voltage(DC) Contact material 5V, 6V, 9V, 12V, 18V, Nil:Standard(5A) F:AgSnO2 type Nil:Class E coil insulation P :High capacity(10A) B :Class B coil insulation(UL) 24V, 48V Note:Last order of made in Thailand JQ relay 10A type was the end of September, 2016. TYPES 1) Standard type Standard type Nominal coil voltage High capacity type 1 Form A 1 Form C 1 Form A Part No. Part No. Part No. 1 Form C Part No. 5 V DC JQ1a-5V-F JQ1-5V-F JQ1aP-5V-F JQ1P-5V-F 6 V DC JQ1a-6V-F JQ1-6V-F JQ1aP-6V-F JQ1P-6V-F 9 V DC JQ1a-9V-F JQ1-9V-F JQ1aP-9V-F JQ1P-9V-F 12 V DC JQ1a-12V-F JQ1-12V-F JQ1aP-12V-F JQ1P-12V-F 18 V DC JQ1a-18V-F JQ1-18V-F JQ1aP-18V-F JQ1P-18V-F 24 V DC JQ1a-24V-F JQ1-24V-F JQ1aP-24V-F JQ1P-24V-F 48 V DC - JQ1-48V-F - JQ1P-48V-F Standard packing: Carton 100 pcs., Case 500 pcs. 2019.06 industrial.panasonic.com/ac/e/ ー1ー © Panasonic Corporation 2019 ASCTB185E 201906 Partly to Be Discontinued: 10A type (Made in Thailand) Last time buy: September 30, 2016 JQ RATING 1. Coil data • Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient temperature, etc. Therefore, please use the relay within ± 5% of rated coil voltage. • ‘Initial’ means the condition of products at the time of delivery. Contact Nominal coil arrangement voltage 1 Form A 5 V DC 6 V DC 9 V DC 12 V DC 18 V DC 24 V DC 1 Form C 5 V DC 6 V DC 9 V DC 12 V DC 18 V DC 24 V DC 48 V DC Pick-up voltage (at 20°C) Standard type: 75%V or less of nominal voltage (Initial) High capacity type: 80%V or less of nominal voltage (Initial) Standard type: 75%V or less of nominal voltage (Initial) High capacity type: 80%V or less of nominal voltage (Initial) Drop-out voltage (at 20°C) 5%V or more of nominal voltage (Initial) 5%V or more of nominal voltage (Initial) Nominal operating current [±10%] (at 20°C) 40.0 mA 33.3 mA 22.2 mA 16.7 mA 11.1 mA Coil resistance [±10%] (at 20°C) Nominal operating power (at 20°C) 125 Ω 180 Ω 405 Ω 720 Ω 1,620 Ω 8.3 mA 2,880 Ω 80 mA 66.7 mA 44.4 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA 62.5 Ω 90 Ω 202.5 Ω 360 Ω 810 Ω 1,440 Ω 5,760 Ω Max. applied voltage 180% of nominal voltage (at 20°C) 200 mW 130% of nominal voltage (at 70°C) [When using relays at 85°C, see Notes*4] 150% of nominal voltage (at 20°C) 400 mW 110% of nominal voltage (at 70°C) [When using relays at 85°C, see Notes*4] 2. Specifications Characteristics Contact Item Arrangement Contact resistance (Initial) Contact material Nominal switching capacity (resistive load) Rating Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (reference value)*1 Insulation resistance (Initial) Breakdown voltage Between open contacts (Initial) Between contact and coil Electrical characteristics Mechanical characteristics Expected life Conditions Temperature rise (coil) Specifications Standard type High capacity type 1 Form C 1 Form A 1 Form C Max. 100 mΩ (By voltage drop 6 V DC 1 A) AgSnO2 type N.O. side: N.O. side: 5 A 125 V AC, 10 A 125 V AC, 2 A 250 V AC, 5 A 250 V AC, 5 A 125 V AC, 10 A 125 V AC, 3 A 30 V AC 5 A 30 V AC 2 A 250 V AC, 5 A 250 V AC, N.C. side: N.C. side: 5 A 30 V DC 5 A 30 V DC 2 A 125 V AC, 3 A 125 V AC, 1 A 250 V AC, 2 A 250 V AC, 1 A 30 V DC 1 A 30 V DC N.O. side: N.O. side: 625 VA, 90 W 1,250 VA, 150 W 625 VA, 150 W 1,250 V AC, 150 W N.C. side: N.C. side: 250 VA, 30 W 500 V AC, 30 W 250 V AC, 110 V DC (0.3 A) N.O.: 5 A, N.C.: 2 A N.O.: 10 A, N.C.: 3 A 200 mW 400 mW 200 mW 400 mW 100 mA, 5 V DC Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “Breakdown voltage” section. 1,000 Vrms for 1 min. 750 Vrms for 1 min. 1,000 Vrms for 1 min. 750 Vrms for 1 min. 4,000 Vrms for 1 min. (Detection current: 10 mA) Max. 45°C Max. 45°C (By resistive method, nominal coil voltage (By resistive method, nominal coil voltage applied to the coil; contact carrying current: applied to the coil; contact carrying current: 5 A, at 70°C) 10 A, at 70°C) 1 Form A Surge breakdown voltage*2 (Between contact and coil) (Initial) 8,000 V Operate time (at nominal voltage) (at 20°C) (Initial) Max. 20 ms (excluding contact bounce time.) Release time (at nominal voltage) (at 20°C) (Initial) Max. 10 ms (excluding contact bounce time) (Without diode) Functional Destructive Functional Vibration resistance Destructive Mechanical (at 180 times / min.) Shock resistance Conditions for operation, transport and storage*3 Max. operating speed Unit weight 294 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.) 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10 µs.) 10 to 55 Hz at double amplitude of 2.0 mm Min. 107 Ambient temperature: –40°C to +70°C (class E insulation), –40°C to +85°C *4 (class B insulation) Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times / min. (at nominal switching capacity) Approx. 7 g * Specifications will vary with foreign standards certification ratings. Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. *4. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1 °C with 20 °C as a reference) and use a coil impressed voltage that is within the maximum applied voltage range. Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー2ー © Panasonic Corporation 2019 ASCTB185E 201906 Partly to Be Discontinued: 10A type (Made in Thailand) Last time buy: September 30, 2016 JQ 3. Expected electrical life Type Switching capacity No. of operations 5 A 125 V AC 3 A 125 V AC 2 A 250 V AC 5 A 30 V DC 5×104 2×105 2×105 105 N.O. 5 A 125 V AC 3 A 125 V AC 2 A 250 V AC 3 A 30 V DC 5×104 2×105 2×105 105 N.C. 2 A 125 V AC 1 A 250 V AC 1 A 30 V DC 2×105 2×105 105 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 5×104 5×104 105 N.O. 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 5×104 5×104 105 N.C. 3 A 125 V AC 2 A 250 V AC 1 A 30 V DC 2×105 2×105 105 1 Form A Standard type 1 Form C 1 Form A High capacity type 1 Form C REFERENCE DATA 1.-(1) Max. switching capacity (1 Form A type) 1.-(2) Max. switching capacity (1 Form C type) 100 100 Contact current, A Contact current, A AC resistive load (High capacity type)N.O.side AC resistive load(High capacity type) 10 5 AC resistive load(Standard type) AC resistive load (Standard type)N.O. side 10 5 3 2 ACresistive load 1 (High capacity type) 1 N.C. side AC resistive load (Standard type) N.C. side 10 100 250 Contact voltage, V 1,000 10 100 250 Contact voltage, V 1,000 Standard type 2. Life curve 3.-(1) Operate & release time (1 Form A type) Ambient temperature:room temperature Tested sample:JQ1-24V-F, 25 pcs. 3.-(2) Operate & release time (1 Form C type) Tested sample:JQ1-24V-F, 25 pcs. 100 125V AC resistive load 10 250V AC resistive load Release time 8 6 4 Max. Max. Min. Min. 2 1 0 1 2 3 Contact current, A 4 5 0 80 Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ 100 120 150 Coil applied voltage, %V ー3ー Operate time Operate & release time, ms Operate & release time, ms Life, ×104 Operate time Release time 8 6 4 Max. Max. Min. Min. 2 0 80 © Panasonic Corporation 2019 100 120 150 Coil applied voltage, %V ASCTB185E 201906 Partly to Be Discontinued: 10A type (Made in Thailand) Last time buy: September 30, 2016 JQ 4.-(1) Coil temperature rise (1 Form A type) Contact carrying current:3 A, 5 A Measured portion:Inside the coil 4.-(2) Coil temperature rise (1 Form C type) Contact carrying current:3 A, 5 A Measured portion:Inside the coil 50 70 60 5A at 70° C Temperature rise, ° C Temperature rise, ° C 40 5A at 85° C 30 20 3A at 70° C 5A at 70° C 3A at 70° C 40 5A at 85° C 30 3A at 85° C 20 3A at 85° C 10 50 10 0 0 100 110 120 130 140 150 160 170 180 190 Coil applied voltage, %V 5.-(1) Ambient temperature characteristics (1 Form A type) Tested sample:JQ1a-24V-F Contact carrying current:3 A, 5 A 110 120 130 140 150 160 Coil applied voltage, %V 5.-(2) Ambient temperature characteristics (1 Form C type) ① Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130 °C) (Carrying current: 3 A) ② Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130 °C) (Carrying current: 5 A) ③ Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115 °C) (Carrying current: 3 A) ④ Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115 °C) (Carrying current: 5 A) ⑤ Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A) ⑥ Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 3 A) ⑦ Pick-up voltage Tested sample:JQ1-24V-F Contact carrying current:3 A, 5 A 400 400 300 Coil applied voltage, %V Coil applied voltage, %V 100 ① ② 200 ③ ⑤ ⑥ ④ 100 300 ① ② 200 ③ ④ ⑤ 100 ⑥ ⑦ 0 20 30 40 50 60 70 80 Ambient temperature, ° C 0 90 20 30 ⑦ 40 50 60 70 80 Ambient temperature, ° C 90 High capacity type 1. Life curve 2.-(1) Operate & release time (1 Form A type) Tested sample:JQ1aP-12V-F, 25 pcs. Ambient temperature:room temperature 2.-(2) Operate & release time (1 Form C type) Tested sample:JQ1P-12V-F, 25 pcs. 100 125V AC resistive load 10 250V AC resistive load 1 0 2 4 8 6 4 Max. Min. Max. Min. 2 6 8 0 10 80 Contact current, A 3.-(1) Coil temperature rise (1 Form A type) 6 4 Max. Max. Min. Min. 2 0 100 120 150 Coil applied voltage, %V 80 100 120 150 Coil applied voltage, %V Contact carrying current:5 A, 10 A Measured portion:Inside the coil 70 70 60 60 10 A at 85° C 10 A at 85° C 50 10 A at 70° C 40 5 A at 70° C 30 5 A at 85° C 10 A at 70° C 50 10 10 120 140 160 Coil applied voltage, %V 180 5 A at 85° C 30 20 100 5 A at 70° C 40 20 0 Release time 8 3.-(2) Coil temperature rise (1 Form C type) Temperature rise, ° C Temperature rise, ° C Contact carrying current:5 A, 10 A Measured portion:Inside the coil Operate time Release time Operate & release time, ms Operate & release time, ms Life, ×104 Operate time 0 100 110 120 Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ 130 140 150 160 Coil applied voltage, %V ー4ー © Panasonic Corporation 2019 ASCTB185E 201906 Partly to Be Discontinued: 10A type (Made in Thailand) Last time buy: September 30, 2016 4.-(1) Ambient temperature characteristics (1 Form A type) JQ 4.-(2) Ambient temperature characteristics (1 Form C type) Tested sample:JQ1aP-24V-F Contact carrying current:5 A, 10 A Tested sample:JQ1P-24V-F Contact carrying current:5 A, 10 A 400 400 Coil applied voltage, %V Coil applied voltage, %V ① ② 300 200 ③ ⑤ ④ ① ② ③ 200 ④ ⑤ 100 100 ⑥ 0 300 20 30 ⑦ ⑥ ⑦ 40 50 60 70 80 Ambient temperature, ° C DIMENSIONS (mm) 0 90 20 30 40 50 60 70 80 Ambient temperature, ° C ① Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130 °C) (Carrying current: 5 A) ② Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130 °C) (Carrying current: 10 A) ③ Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115 °C) (Carrying current: 5 A) ④ Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115 °C) (Carrying current: 10 A) ⑤ Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 10 A) ⑥ Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A) ⑦ Pick-up voltage 90 CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website. Schematic (Bottom view) External dimensions CAD 1 Form A 1 Form A 10 1 Form C COM 20 COM N.O. N.O. coil Coil 15.6 N.C. 0.4 4.2 10.16 7.62 0.5 dia. 7.62 0.3 0.3 7.62 0.8 Dimension: General tolerance ±0.2 Less than 1mm: Min. 1mm less than 5mm:±0.3 ±0.4 Min. 5mm: PC board pattern (Bottom view) 1 Form A 1 Form C 10 20 10.16 15.6 1 Form C 7.62 4-φ1.3 dia. 7.62 10.16 7.62 5-φ1.3 dia. 7.62 0.4 Tolerance:±0.1 4.2 10.16 7.62 0.5 dia. 5.08 0.3 2.54 Tolerance:±0.1 7.62 0.8 0.8 0.3 0.3 Dimension: General tolerance ±0.2 Less than 1mm: Min. 1mm less than 5mm:±0.3 ±0.4 Min. 5mm: Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー5ー © Panasonic Corporation 2019 ASCTB185E 201906 Partly to Be Discontinued: 10A type (Made in Thailand) Last time buy: September 30, 2016 JQ SAFETY STANDARDS Item UL/C-UL (Recognized) CSA (Certified) File No. Contact rating Standard type (5A) 1 FormA E43028 LR26550 5A 125V AC 5A 277V AC 5A 30V DC 0.3A 110V DC 1/10HP 125V AC 1/6HP 277V AC 5A 125V AC 40011435 5A 277V AC 5A 30V DC 0.3A 110V DC 1/10HP 125V AC 1/6HP 277V AC Standard type (5A) 1 FormC E43028 5A 125V AC LR26550 5A 277V AC 5A 30V DC 0.3A 110V DC 1/10HP 125V AC 1/6HP 277V AC High capacity type E43028 (10A) 1 FormA High capacity type E43028 (10A) 1 FormC 5A 250V AC (cosφ =0.4) B 11 04 13461 296 5A 250V AC (cosφ =0.4) 5A 30V DC (0ms) 817138 3(2)A 125V AC 2(1)A 250V AC 5A 30V DC 5A 125V AC 40011435 5A 277V AC 5A 30V DC 0.3A 110V DC 1/10HP 125V AC 1/6HP 277V AC 5A 250V AC (cosφ =0.4) (N.O.) 3A 250V AC (cosφ =0.4) (N.C.) B 11 04 13461 296 5A 250V AC (cosφ =0.4) 5A 30V DC (0ms) 817138 3(2)A 125V AC 2(1)A 250V AC 5A 30V DC 10A 125V AC LR26550 8A 277V AC 5A 30V DC 0.3A 110V DC 1/6HP 125V AC 1/6HP 277V AC 10A 125V AC 40011435 8A 277V AC 5A 30V DC 0.3A 110V DC 1/6HP 125V AC 1/6HP 277V AC 10A 250V AC (cosφ =0.4) B 11 04 13461 296 10A 250V AC (cosφ =0.4) 817138 5A 30V DC (0ms) 5(3)A 250V AC 5A 30V DC 10A 125V AC LR26550 8A 277V AC 5A 30V DC 0.3A 110V DC 1/6HP 125V AC 1/6HP 277V AC 10A 125V AC 40011435 8A 277V AC 5A 30V DC 0.3A 110V DC 1/6HP 125V AC 1/6HP 277V AC (N.O.) B 11 04 10A 250V AC (cosφ =0.4) 13461 296 (N.C.) 3A 250V AC (cosφ =0.4) 10A 250V AC (cosφ =0.4) 817138 5A 30V DC (0ms) 5(3)A 250V AC 5A 30V DC Top Contact rating SEMKO(Certified) Rating Note about relay installation orientation File No. TÜV(Certified) File No. NOTES Contact rating VDE(Certified) File No. File No. Contact rating When installing with the relay terminals parallel to the ground, the contact terminals at the bottom and the coil terminals at the top, component friction will occur after numerous switching actions or due to vibration in the non-excitation state. Since this may cause the relay to stop functioning when the pick-up voltage increases even if the nominal voltage is applied, please do not install using this orientation. Bottom For Cautions for Use. Please refer to "the latest product specifications" when designing your product. •Requests to customers: https://industrial.panasonic.com/ac/e/salespolicies/ Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー6ー © Panasonic Corporation 2019 ASCTB185E 201906 GUIDELINES FOR POWER RELAYS AND HIGH-CAPACITY DC CUT OFF RELAYS USAGE For cautions for use, please read “GUIDELINES FOR RELAY USAGE”. https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp Precautions for Coil Input Long term current carrying A circuit that will be carrying a current continuously for long periods without relay switching operation. (circuits for emergency lamps, alarm devices and error inspection that, for example, revert only during malfunction and output warnings with form B contacts) Continuous, long-term current to the coil will facilitate deterioration of coil insulation and characteristics due to heating of the coil itself. For circuits such as these, please use a magnetic-hold type latching relay. If you need to use a single stable relay, use a sealed type relay that is not easily affected by ambient conditions and make a failsafe circuit design that considers the possibility of contact failure or disconnection. DC Coil operating power Steady state DC current should be applied to the coil. The wave form should be rectangular. If it includes ripple, the ripple factor should be less than 5%. However, please check with the actual circuit since the electrical characteristics may vary. The rated coil voltage should be applied to the coil and the set/reset pulse time of latching type relay differs for each relays, please refer to the relay's individual specifications. Maximum allowable voltage and temperature rise Proper usage requires that the rated coil voltage be impressed on the coil. Note, however, that if a voltage greater than or equal to the maximum continuous voltage is impressed on the coil, the coil may burn or its layers short due to the temperature rise. Furthermore, do not exceed the usable ambient temperature range listed in the catalog. Operate voltage change due to coil temperature rise (Hot start) In DC relays, after continuous passage of current in the coil, if the current is turned OFF, then immediately turned ON again, due to the temperature rise in the coil, the pick-up voltage will become somewhat higher. Also, it will be the same as using it in a higher temperature atmosphere. The resistance/temperature relationship for copper wire is about 0.4% for 1°C, and with this ratio the coil resistance increases. That is, in order to operate of the relay, it is necessary that the voltage be higher than the pick-up voltage and the pick-up voltage rises in accordance with the increase in the resistance value. However, for some polarized relays, this rate of change is considerably smaller. Coil connection When connecting coils of polarized relays, please check coil polarity (+,-) at the internal connection diagram (Schematic). If any wrong connection is made, it may cause unexpected malfunction, like abnormal heat, fire and so on, and circuit do not work. Avoid impressing voltages to the set coil and reset coil at the same time. Ambient Environment Dew condensation Usage, Transport, and Storage Conditions Condensation occurs when the ambient temperature drops suddenly from a high temperature and humidity, or the relay is suddenly transferred from a low ambient temperature to a high temperature and humidity. Condensation causes the failures like insulation deterioration, wire disconnection and rust etc. Panasonic Corporation does not guarantee the failures caused by condensation. The heat conduction by the equipment may accelerate the cooling of device itself, and the condensation may occur. Please conduct product evaluations in the worst condition of the actual usage. (Special attention should be paid when high temperature heating parts are close to the device. Also please consider the condensation may occur inside of the device.) During usage, storage, or transportation, avoid locations subjected to direct sunlight and maintain normal temperature, humidity and pressure conditions. Temperature/Humidity/Pressure When transporting or storing relays while they are tube packaged, there are cases the temperature may differ from the allowable range. In this case be sure to check the individual specifications. Also allowable humidity level is influenced by temperature, please check charts shown below and use relays within mentioned conditions. (Allowable temperature values differ for each relays, please refer to the relay's individual specifications.) Icing Condensation or other moisture may freeze on relays when the temperature become lower than 0°C.This icing causes the sticking of movable portion, the operation delay and the contact conduction failure etc. Panasonic Corporation does not guarantee the failures caused by the icing. The heat conduction by the equipment may accelerate the cooling of relay itself and the icing may occur. Please conduct product evaluations in the worst condition of the actual usage. Low temperature and low humidity The plastic becomes brittle if the switch is exposed to a low temperature, low humidity environment for long periods of time. High temperature and high humidity Storage for extended periods of time (including transportation periods) at high temperature or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and/or it may interfere with the functions. Check out the atmosphere in which the units are to be stored and transported. 1) Temperature: The tolerance temperature range differs for each relays, please refer to the relay’s individual specifications 2) Humidity: 5 to 85 % RH 3) Pressure: 86 to 106 kPa Humidity, %R.H. 85 Allowable range (Avoid icing when used at temperatures lower than 0° C) 5 –40 (Avoid condensation when used at temperatures higher than 0° C) 0 Ambient temperature, ° C 85 Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー7ー c Panasonic Corporation 2019 ASCTB412E 201903 GUIDELINES FOR POWER RELAYS AND HIGH-CAPACITY DC CUT OFF RELAYS USAGE Package In terms of the packing format used, make every effort to keep the effects of moisture, organic gases and sulfide gases to the absolute minimum. Silicon When a source of silicone substances (silicone rubber, silicone oil, silicone coating materials and silicone filling materials etc.) is used around the relay, the silicone gas (low molecular siloxane etc.) may be produced. This silicone gas may penetrate into the inside of the relay. When the relay is kept and used in this condition, silicone compound may adhere to the relay contacts which may cause the contact failure. Do not use any sources of silicone gas around the relay (Including plastic seal types). NOx Generation When relay is used in an atmosphere high in humidity to switch a load which easily produces an arc, the NOx created by the arc and the water absorbed from outside the relay combine to produce nitric acid. This corrodes the internal metal parts and adversely affects operation. Avoid use at an ambient humidity of 85%RH or higher (at 20°C). If use at high humidity is unavoidable, please contact our sales representative. Others Cleaning 1) Although the environmentally sealed type relay (plastic sealed type, etc.) can be cleaned, avoid immersing the relay into cold liquid (such as cleaning solvent) immediately after soldering. Doing so may deteriorate the sealing performance. 2) Cleaning with the boiling method is recommended(The temperature of cleaning liquid should be 40°C or lower ). Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may cause breaks in the coil or slight sticking of the contacts due to ultrasonic energy. Please refer to "the latest product specifications" when designing your product. •Requests to customers: https://industrial.panasonic.com/ac/e/salespolicies/ Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー8ー c Panasonic Corporation 2019 ASCTB412E 201903 Please contact .......... Electromechanical Control Business Division 1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan industral.panasonic.com/ac/e/ ©Panasonic Corporation 2019 ASCTB185E-1 201906 Specifications are subject to change without notice.
JQ1P-5V 价格&库存

很抱歉,暂时无法提供与“JQ1P-5V”相匹配的价格&库存,您可以联系我们找货

免费人工找货