JS1F-B-48V-F

JS1F-B-48V-F

  • 厂商:

    NAIS(松下)

  • 封装:

    插件,16x22mm

  • 描述:

  • 数据手册
  • 价格&库存
JS1F-B-48V-F 数据手册
Automation Controls Catalog VDE Cubic type 1a/1c 10A power relays RoHS compliant Protective construction: Flux-resistant type/Sealed type JS RELAYS FEATURES TYPICAL APPLICATIONS 1. Miniature size with universal terminal footprint 2. High contact capacity: 10 A 3. TV-5 type available (Standard type) 1 Form A type → TV-5 1 Form C type → TV-5 (N.O. side only) 4. VDE, TÜV also approved 5. Sealed construction for automatic cleaning (Standard type) 6. Class B and F coil insulation type also available 7. EN60335-1 GWT compliant (Tested by VDE) type available 8. Surge voltage 6 kV type also available 1. Home appliances Air conditioner, heater, etc. 2. Office machines PPC, facsimile, etc. 3. Vending machines ORDERING INFORMATION JS F Contact arrangement 1: 1 Form C (Standard) 1a: 1 Form A (Standard) 1aP: 1 Form A (Long endurance type)* Protective construction Nil: Sealed type F: Flux-resistant type Coil insulation class Nil: Class E insulation B: Class B insulation F: Class F insulation Nominal coil voltage (DC) 5V, 6V, 9V, 12V, 18V, 24V, 48V Contact material F: AgSnO2 type Flame resistance and tracking resistance Nil: – T: EN60335-1 (Conform) Surge voltage 6K: 6kV type Standard: UL, CSA, VDE, TÜV (Standard type) UL, CSA, VDE (Long endurance type and EN60335-1 GWT compliant type) UL, CSA (Surge voltage 6kV type) * 1 Form A long endurance type is Flux-resistant type only (Class B insulation only). 2014.02 industrial.panasonic.com/ac/e/ –1– © Panasonic Corporation 2014 ASCTB186E 201402-T JS TYPES Contact arrangement Nominal coil voltage Sealed type Part No. Flux-resistant type Part No. 1 Form A (Standard) 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC JS1a-5V-F JS1a-6V-F JS1a-9V-F JS1a-12V-F JS1a-18V-F JS1a-24V-F JS1a-48V-F JS1aF-5V-F JS1aF-6V-F JS1aF-9V-F JS1aF-12V-F JS1aF-18V-F JS1aF-24V-F JS1aF-48V-F 1 Form A Long endurance type 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC – – – – – – – JS1aPF-B-5V-F JS1aPF-B-6V-F JS1aPF-B-9V-F JS1aPF-B-12V-F JS1aPF-B-18V-F JS1aPF-B-24V-F JS1aPF-B-48V-F 1 Form C (Standard) 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC JS1-5V-F JS1-6V-F JS1-9V-F JS1-12V-F JS1-18V-F JS1-24V-F JS1-48V-F JS1F-5V-F JS1F-6V-F JS1F-9V-F JS1F-12V-F JS1F-18V-F JS1F-24V-F JS1F-48V-F Standard packing Carton: 100 pcs. Case: 500 pcs. Notes: 1. Class B and F coil insulation types available. Ex) JS1aF-B-12V-F, JS1aF-F-12V-F 2. 1 Form A long endurance type is Flux-resistant type only (Class B insulation only). 3. EN60335-1 GWT compliant types available. When ordering, please add suffix “T”. Ex) JS1aF-B-12V-FT 4. Surge voltage 6kV types available. When ordering, please add suffix “6K” (except for Long endurance type and EN60335-1 GWT compliant type). Ex) JS1aF-B-12V-F-6K RATING 1. Coil data Nominal coil voltage Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) Nominal operating current [±10%] (at 20°C 68°F) 5V DC 72 mA 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC 60 mA 40 mA 30 mA 20 mA 15 mA 7.5mA 70%V or less of nominal voltage (Initial) 10%V or more of nominal voltage (Initial) Coil resistance [±10%] (at 20°C 68°F) Nominal operating power (at 20°C 68°F) Max. applied voltage (at 70°C 158°F) 69.4Ω 100 225 400 900 1,600 6,400 Ω Ω Ω Ω Ω Ω 130%V of nominal voltage 360mW [When using relays at 85°C 185°F, see Note*] Note: * When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with 20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range. Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/ –2– © Panasonic Corporation 2014 ASCTB186E 201402-T JS 2. Specifications Characteristics Contact Item Contact material Contact resistance (Initial) Arrangement Specifications AgSnO2 type Max. 100 mΩ (By voltage drop 6 V DC 1A) 1 Form A, 1 Form C 1 Form A Long endurance type 10 A 250 V AC (NO), 10 A 125 V AC, 10 A 250 V AC, 10 A 277 V AC, 5 A 30 V DC 6 A 277 V AC, 5 A 30 V DC 2,500VA 150W (NO), 1,662VA 150W (NC) 2,770VA 150W 250V AC, 100V DC (0.5A) 10A (AC), 5A (DC) 360mW 100mA, 5V DC Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section. Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (reference value)*1 Insulation resistance (Initial) Rating Breakdown voltage (Initial) Electrical characteristics Between open contacts Between contact and coil 750 Vrms for 1 min. (Detection current: 10 mA) 1,500 Vrms for 1 min. (Detection current: 10 mA) Max. 35°C 95°F (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 10A, at 70°C 158°F) Max. 10 ms (excluding contact bounce time.) Max. 10 ms (excluding contact bounce time) (Without diode) 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.) 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10µs.) 10 to 55 Hz at double amplitude of 2 mm Min. 107 Temperature rise (coil) Operate time (at nominal voltage) (at 20°C 68°F) Release time (at nominal voltage) (at 20°C 68°F) Functional Destructive Functional Vibration resistance Destructive Mechanical (at 180 times/min.) Shock resistance Mechanical characteristics Expected life Conditions 1×105 [10A 125V AC, 6A 277V AC, 5A 30V DC] 5×104 (NO contact only) [10A 250V AC] Electrical (resistive load) 2×105 [10A 277V AC] 1.5×105 [10A 250V AC (at 20 times/min., 105°C 221°F)] 1×105 [5A 30V DC] –40°C to +70°C –40°F to +158°F (Class E insulation) –40°C to +85°C –40°F to +185°F –40°C to +105°C –40°F to +221°F*3; (Class B insulation)*3 Humidity: 5 to 85% R.H. (Not freezing and –40°C to +105°C –40°F to +221°F condensing at low temperature) (Class F insulation)*3 Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at nominal switching capacity) Approx. 12 g .423 oz Conditions for operation, transport and storage*2 Max. operating speed Unit weight Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. *3. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with 20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range. REFERENCE DATA 1. Maximum value for switching capacity 2.-(1) Coil temperature rise 2.-(2) Coil temperature rise Sample: JS1a-24V-F Measured portion: Inside the coil Contact current: 5 A Sample: JS1a-24V-F Measured portion: Inside the coil Contact current: 10 A 60 100 60 10 1 DC resistive load 10 30 100 26°C 70°C 85°C 40 30 50 30 20 10 10 0 100 120 140 160 70°C 85°C 40 20 Contact voltage, V 0 100 Coil applied voltage, %V Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/ Temperature rise, °C AC resistive load Temperature rise, °C Contact current, A 26°C 50 –3– 120 140 160 Coil applied voltage, %V © Panasonic Corporation 2014 ASCTB186E 201402-T JS 3. Life curve 4. Operate/release time 5. Ambient temperature characteristics Ambient temperature: Room temperature Sample: JS1-12V-F, 25 pcs. Sample: JS1-12V-F, 6 pcs. Life, ×104 125V AC resistive load 10 Changing ration, % Operate/release time, ms 100 10 Operate time 8 10 6 20 40 60 80 4 1 2 3 4 5 6 7 8 9 0 10 80 100 Contact current, A 120 Ambient temperature °C –10 Max. – x Min. Max. – x Min. Release time 0 Drop-out voltage –60 –40 –20 0 2 1 Pick-up voltage 20 –20 140 Coil applied voltage, %V DIMENSIONS (mm inch) The CAD data of the products with a CAD Data External dimensions CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ Schematic (Bottom view) 1 Form A N.O. 16 .630 0.4 .016 COIL PC board pattern (Bottom view) 1 Form A (Standard, High Power) 4-1.3 dia. 4-.051 dia. COM 3.9 .154 0.24 .009 12 .472 0.8 .031 0.8 .031 1 Form C N.O. 0.4 .016 2 16 .630 1.2 .047 2.3 .091 COIL 12.2 .480 1 Form C 3 N.O. 12 .472 1 2 .079 COM N.C. (Standard) 4 N.C. 5 5-1.3 dia. 5-.051 dia. 0.4 .016 2 .079 12.2 .480 22 .866 12 .472 Note: Terminal No. 4 is only for Standard 1 Form C type Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: 2 .079 General tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 12.2 .480 Tolerance: ±0.1 ±.004 SAFETY STANDARDS File No. E43028 UL/C-UL (Recognized) Contact rating 10A 125V AC, 6A 277V AC 5A 30V DC, 1/8HP 125V AC 1/8HP 277V AC 12A 125V AC 12A 277V AC 10A 125V AC (N.O., 85°C) 4FLA/4LRA125V AC 105°C (N.O.) 2FLA/4LRA125V AC 105°C (N.C.) 1/3HP 277V AC 75°C N.O. File No. LR26550 CSA (Certified) Contact rating 10A 125V AC 12A 125V AC 6A 277V AC 12A 277V AC 5A 30V DC 1/8HP 125V AC 1/8HP 277V AC File No. 40011475 VDE (Certified) Contact rating 10A 125V AC (cosφ =1.0) 6A 250V AC (cosφ =1.0) File No. B 12 09 13461 336 TÜV (Certified) Rating 10A 125V AC (cosφ =1.0) 6A 250V AC (cosφ =1.0) NOTES 1. For cautions for use, please read “GENERAL APPLICATION GUIDELINES” on page B-1. Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/ –4– © Panasonic Corporation 2014 ASCTB186E 201402-T
JS1F-B-48V-F 价格&库存

很抱歉,暂时无法提供与“JS1F-B-48V-F”相匹配的价格&库存,您可以联系我们找货

免费人工找货