JV-N
COMPACT FLAT
POWER RELAY FOR
HEATER LOADS
JV-N RELAYS
FEATURES
22
.866
16
.630
10.9
.429
Compliance with RoHS Directive
• High 16 A capacity
The contacts are high capacity 16A,
125 V AC.
• Compact, flat type with low 10.9 mm
.429 inch height
Compact flat type with low surface area
of 16 × 22 mm .630 × .866 inch and
height of 10.9 mm .429 inch.
• High sensitivity at 200 mW
High sensitivity at 200 mW coil power
consumption.
• Represses contact terminal heat
The contact terminals are larger and
thicker compared to the existing JV relay.
This limits the rise in temperature of the
terminals when there is a large current
flowing to approx. 28°C 62°F (normal
current of 16 A).
• Conforms to the various safety
standards
UL/CSA, TÜV approved.
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances.
(The suffix “F” should be added to the
part number)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
SPECIFICATIONS
Contact
Characteristics
Arrangement
1 Form A
Initial contact resistance, max.
Max. 100 mΩ
(By voltage drop 6 V DC 1 A)
Contact material
AgSnO2 type
Nominal switching
16 A 125 V AC, 10 A 277 V AC
capacity
10 A 30 V DC, 10 A 125 V AC
Max. switching power
2,770 VA, 300 W
Rating
(resistive
Max. switching voltage
277 V AC, 30 V DC
load)
Max. switching current
16 A (AC 125 V), 10 A (DC)
Min. switching capacity#1
100 mA, 5 V DC
(Reference value)
Expected life (min. ope.)
2×107
Mechanical (at 180 cpm)
3×104
Sealed 16 A 125 V AC
Electrical
at resistive type
10 A 30 V DC
105
load
Flux-resistant type
105
(at 20 cpm) 10 A 125 V AC
Max. operating speed
Operate time*1 (at nominal voltage)
Release time*2 (at nominal voltage)
Initial insulation resistance
Initial breakdown Between open
contacts
voltage
(Detection
Between contacts
current: 10 mA
and coil
Surge voltage between contact and
coil
Temperature rise
Conditions in case of operation,
transport and storage*8
Coil
Nominal operating power
200 mW (DC 4.5 to 48 V)
600 mW (DC 100 V)
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Excluding contact bounce time
*2 Excluding contact bounce time, without diode
*3 By resistive method; nominal voltage applied to the coil; contact carrying current:
16A, at 70°C 158°F
*4 Nominal voltage applied to the coil, at 60°C 140°F
5
* Half-wave pulse of sine wave: 11 ms; detection time: 10 µs
*6 Half-wave pulse of sine wave: 6 ms
*7 Detection time: 10 µs
*8 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT.
Shock resistance
Vibration
resistance
Functional
Destructive
Functional
Destructive
Unit weight
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
20 cpm
Max. 12 ms (DC 4.5 V to 48 V)
Max. 8 ms (DC 100 V)
Max. 5 ms
Min. 1,000 MΩ (at 500 V DC)
1,000 Vrms for 1 min.
2,500 Vrms for 1 min.
4,500 V
Max. 45°C (DC 4.5 V to 48 V) *3
Max. 55°C (DC 100 V)*4
Ambient temperature
–40 to 70°C –40 to 158°F
(DC 4.5 to 48 V)
–40 to 60°C –40 to 140°F
(DC 100V)
Humidity: 5 to 85 % R.H.
(Note freezing and condensing
at low temperature)
Air pressure: 86 to 106 kPa
200 m/s2{20G}*5
1,000 m/s2{100G}*6
10 to 55 Hz *7
at double amplitude of 1.6 mm
10 to 55 Hz at double
amplitude of 2 mm
Approx. 8g .28 oz
JV-N
TYPICAL APPLICATIONS
ORDERING INFORMATIONS
• AV equipment: TV’s, VTR’s, etc.
• OA equipment
• HA equipment
1a
Ex. JVN
F – 4.5 V – F
Contact arrangement
Protective construction
Coil voltage (DC)
Contact material
1a: 1 Form A
Nil: Sealed type
F: Flux-resistant type
4.5, 6, 9, 12,18,
24, 48, 100 V
F: AgSnO2 type
UL/CSA, TÜV approved type is standard.
Please inquire about the previous products (Cadmium containing parts).
TYPES AND COIL DATA (at 20°C 68°F)
Part No.
Sealed type
JVN1a-4.5V-F
JVN1a-6V-F
JVN1a-9V-F
JVN1a-12V-F
JVN1a-18V-F
JVN1a-24V-F
JVN1a-48V-F
JVN1a-100V-F
Flux-resistant
type
Nominal
voltage,
V DC
Pick-up
voltage
V DC (max.)
Drop-out
voltage
V DC (min.)
Coil
resistance,
W (±10%)
JVN1aF-4.5V-F
JVN1aF-6V-F
JVN1aF-9V-F
JVN1aF-12V-F
JVN1aF-18V-F
JVN1aF-24V-F
JVN1aF-48V-F
JVN1aF-100V-F
4.5
6
9
12
18
24
48
100
3.375
4.5
6.75
9
13.5
18
36
60
0.23
0.3
0.45
0.6
0.9
1.2
2.4
4
101
180
405
720
1,620
2,880
11,520
16,600
Nominal
operating
current,
mA (±10%)
44.4
33.3
22.2
16.7
11.1
8.3
4.2
6
Nominal
operating
power,
mW
200
200
200
200
200
200
200
600
Max.
allowable
voltage,
V DC
6.75
9
13.5
18
27
36
72
110
DIMENSIONS
mm inch
22
.866
16
.630
PC board pattern
4
.157
12.7
.500
1.0
.039
0.5
.020
1.6
.063
2-0.9 dia.
2-.035 dia.
17.78
.700
0.4 10.5
.016 .413
COM
17.78
.700
NO
(R)
(R)
2.0
.079
12.7
.500
10.16
.400
Dimension:
General tolerance
Max. 1mm .039 inch:
±0.2 ±.008
1 to 5mm .039 to .197 inch: ±0.3 ±.012
Min. 5mm .197 inch:
±0.4 ±.016
10.16
.400
2.0
.079
REFERENCE DATA
1. Max. switching power
Sample: JVN1aF-12 V-F, 6 pcs.
point measured: coil inside
Contact current: 16 A
AC resistive load
1
9
8
7
operate time
6
5
Max.
–
x
Min.
4
3
release time
2
1
10
100
Contact voltage, V
1,000
0
80
100
120
140
Max.
–
x
Min.
160
Temperature rise, °C
operate & release time, ms
Contact current, A
3. Coil temperature rise
Sample: JVN1aF-12 V-F, 6 pcs.
10
100
16
10
2. Operate/release time
50
40
Ambient temperature 30°C
30
Ambient temperature 70°C
20
10
0
80
Coil applied voltage, %V
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
100
120
140
160
Coil applied voltage, %V
JV-N
4. Ambient temperature characteristics
Sample: JVN1aF-12 V-F, 6 pcs.
Variation
ratio, %
20
–40 –20
0
Drop-out
voltage
10
Pick-up
voltage
20 40 60 80
Ambient
temperature, °C
–10
–20
For Cautions for Use, see Relay Technical Information.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.