• 7-segment LCD with 8.7 mm 0.343 in
character height (total digits: 8)
Backlight can be switched between green and red (for
backlight type)
One-touch installation type
Installation frame type
PC board mounting type
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
panasonic.net/id/pidsx/global
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
■■Selection guide.............................. P.1401
■■Options.......................................... P.1428
Features
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
RoHS compliance
• Counting Speed Switchable between 30 Hz
and 2 kHz (for panel mounting type)
• Battery Replacement Easy on Environment
• IP66 compliant for resistance against
negative environmental influences
(only when panel surface uses rubber
packing) (for installation frame type)
• Finger protection
Screw terminals are constructed to
protect fingers to ensure safety (for screw
terminal section)
• Replaceable panel cover
Large display in a small body
Panel design can be changed from standard (ash
gray) to black (sold separately)
IP66
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
PRODUCT TYPES
Panel mounting type
Installation
type
Counters
Hour Meters
Options
Limit Switches
Temperature
Controllers
Solenoids
Fan Motors
Backlight
No
Yes
LC2H-FE-2KK
Voltage input type (4.5 to 30 V DC)
30 Hz/2 kHz
switchable
No
Yes
LC2H-FE-DL-2KK
Yes
Yes
LC2H-FE-DL-2KK-B
Free voltage input type (24 to 240 V AC/DC)
30 Hz
No
Yes
LC2H-FE-FV-30
No
Yes
LC2H-F-2KK
Voltage input type (4.5 to 30 V DC)
30 Hz/2 kHz
switchable
No
Yes
LC2H-F-DL-2KK
Free voltage input type (24 to 240 V AC/DC)
30 Hz
Non-voltage input type
One-touch
installation
type
Non-voltage input type
Timers
Time Switches
Counting
speed
Input method
Installation
frame type
Model No.
Yes
Yes
LC2H-F-DL-2KK-B
No
Yes
LC2H-F-FV-30
Counting
speed
Backlight
Front reset
button
2 kHz
No
Yes
LC2H-C-2K-N
30 Hz
No
Yes
LC2H-C-30-N
Notes: 1) Please ask us about types without front reset button.
2) Products without backlight are listed as standard types under "Specifications".
PC board mounting type
Input method
Selection
Guide
Applications
Non-voltage input type
LC2H series
Note: There is no front reset button on the PC board mounting type.
LC4H series
Front reset
button
Model No.
LC2H Total Counter
1404
CAUTIONS FOR USE
Non-voltage input type
Common to both the panel mounting type, and the PC board mounting type
• Never apply voltage to the non-voltage input type.
This will damage the internal elements.
Also, since there is a possibility of erroneous operation,
do not connect in parallel the inputs of a non-voltage
input type and another counter from a single input signal.
• Since the current flow is very small from the count
input and reset input terminals ( and
on the panel
mounting type and terminals
to
and
to
on the
PC board mounting type) please use relays and switches
with high contact reliability.
• When inputting with an open collector of a transistor, use
a transistor for small signals in which ICBO is 1 μA or less
and always input with no voltage.
• When wiring, try to keep all the input lines to the count and
reset inputs as short as possible and avoid running them
together with high voltage and power transmission lines or in a
power conduit.
Also, malfunctions might occur if the floating capacitance of
these wires exceeds 500 pF (10 m 32.808 ft for parallel wires
of 2 mm2 0.003 in2).
When using 2 kHz mode, use with a wiring floating capacitance
of 120 pF (3 m 9.843 ft for parallel wires of 2 mm2 0.003 in2).
In particular, when using shielded wiring, be careful of the
capacitance between wires.
PC board mounting type
• For external power supply use manganese dioxide or
lithium batteries (CR type: 3V).
• Always reset after external power is applied and confirm
that the display reads "0".
• Make the wiring from the battery to the counter unit as
short as absolutely possible. Also, be careful of polarity.
• Calculate battery life with the following formula.
t = A/I
t: battery life [h]
I: LC2H current consumption [mA]
A: battery capacity until minimum
operation voltage is reached [mAh]
• Hand solder to the lead terminal.
Do not dip solder. With the tip of the soldering iron at 300 °C 572 °F
perform soldering within 3 seconds (for 30 to 60 W soldering iron).
Voltage input type
• Be aware that applying more than 30 V DC to count input
terminals and , and reset input terminals and
will cause damage to the internal elements.
• For external resetting use H level (application of 4.5 to
30 V DC) between reset terminals and of the rear
terminals. In this case, connect (+) to terminal 3 and (-)
to terminal . This is the valid polarity; therefore, the
counter will not work if reversed.
• When wiring, try to keep all the input lines to the count and reset
inputs as short as possible and avoid running them together with
high voltage and power transmission lines or in a power conduit.
Also, malfunctions might occur if the floating capacitance of
these wires exceeds 500 pF (10 m 32.808 ft for parallel wires of
2 mm2 0.003 in2).
FIBER
SENSORS
LASER
SENSORS
Free voltage input type
• Use count input terminals
and for free voltage input
and reset terminals
and for non-voltage input.
• Be aware that the application of voltage that exceeds the
voltage range of the H level to the count input terminal,
and the application of voltage to the reset input terminal,
can cause damage to the internal elements.
• Since the current flow is very small from reset input
terminal
, please use relays and switches with high
contact reliability.
• When inputting a reset with an open collector of a
transistor, use a transistor for small signals in which ICBO
is 1 μA or less and always input with no voltage.
• To reset externally, short reset input terminals
and
on the rear.
• Input uses a high impedance circuit; therefore, erroneous
operation may occur if the influence of induction voltage
is present. If you plan to use wiring for the input signal
that is 10 m 32.808 ft or longer (wire capacitance 120
pF/m at normal temperature), we recommend the use of
a CR filter or the connection of a bleeder resistor.
How to reset multiple panel mounting type
counters all at once (input is the same for count)
Non-voltage input type
D
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
D
D
3 4
PHOTOELECTRIC
SENSORS
3 4
HUMAN
MACHINE
INTERFACES
Tr
or
3 4
ENERGY
MANAGEMENT
SOLUTIONS
Notes: 1) Use the following as a guide for choosing transistors used for
input (Tr).
Leakage current < 1 μA
2) Use as small a diode (D) as possible in the forward voltage
so that the voltage between terminals 3 and 4 during reset
input meets the standard value (0.5 V).
(At IF = 20 μA, forward voltage: Max. 0.1 V)
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Voltage input type
3 4
3 4
+V
R
Tr
or
3 4
+V
3 4
Timers
Time
Switches
Note: Make sure that H (reset ON) level is at least 4.5 V.
Counters
Hour
Meters
Backlight luminance
To prevent varying luminance among backlights when
using multiple backlight types, please use the same
backlight power supply.
24 V DC
2
5
2
Green
5
Options
Limit
Switches
Temperature
Controllers
Solenoids
Fan
Motors
2
2
6
Red
6
24 V DC
Selection
Guide
Applications
LC2H
series
LC4H
series
很抱歉,暂时无法提供与“LC2H-C-2K-N”相匹配的价格&库存,您可以联系我们找货
免费人工找货