LC2H
Panel mounting type
One-touch installation type
Panel mounting type
Installation frame type
PC board mounting type
PRODUCT CHART
Type
DIN HALF SIZE
LCD COUNTER
Features
8.7mm
.343inch
1. 8.7 mm .343 inch Character Height
(previously 7 mm)
Easy-to-read character height increased
from 7 mm to 8.7 mm .276 inch to .343
inch.
2. Plenty of Digits
8 digits
3. Counting Speed Switchable between
2 kHz and 30 Hz
4. Panel Mounting Type Features 2 Installation Methods
Comes with very easy one-touch installation type and also installation frame type
that uses the bracket on the timer/counter.
Choose a method that suits the application.
Non-voltage input type
LC2H
5. Battery Replacement Easy on Environment
To replace battery simply remove body for
the one-touch installation type, and remove battery lid for the installation frame
type.
6. Screw Terminals Designed for Safety
Built in finger protection.
7. Panel Covers Replacable
(Standard color is ash gray.)
Change the panel design by replacing
with a black panel cover.
8. Conforms to IP66 Protective Construction (Only installation frame
type.) (Front panel surface)
9. Input Methods
1) Non-voltage input method
2) Voltage input method
3) Free voltage input method
10. Backlight Type Added to Series and
Now 2-color Switchable (green/red)
Easy viewing even in dark places and
switchable between green and red (Voltage input type).
11. Conforms to Safety Regulations
䡬
Backlight type
Voltage input type
(4.5 to 30 V DC)
䡬
䡬
䡬
Free voltage input type
(24 to 240 V AC/DC)
䡬
䡬
䡬
One-touch installation type
䡬
Standard type
Voltage input type
(4.5 to 30 V DC)
Installation frame type
Installation type
Panel
mounting
type
—
Part No.
LC2H-FE-2KK
LC2H-FE-DL-2KK
LC2H-FE-FV-30
—
Input method
Non-voltage input type
Voltage input type (4.5 to 30 V DC)
Free voltage input type (24 to 240 V AC/DC)
—
Front reset
Yes
Part No.
LC2H-FE-DL-2KK-B
䡬
Counting speed
2 kHz/30 Hz switchable
30 Hz
Front reset
Yes
Input method
Voltage input type (4.5 to 30 V DC)
PC board mounting type
PRODUCT TYPES
No. digits
1. Panel mounting type
1) One-touch installation type
1 Standard type
8 digits
Counting speed
2 kHz/30 Hz switchable
Note) Please ask us about types without front resetting.
No. digits
8 digits
2 Backlight type
72
07/2004
No. digits
30 Hz
2 kHz/30 Hz switchable
Counting speed
2) Installation frame type
1 Standard type
8 digits
Counting speed
2 kHz/30 Hz switchable
Note) Please ask us about types without front resetting.
2 Backlight type
No. digits
8 digits
No. digits
Front reset
Yes
Front reset
Yes
Front reset
Part No.
LC2H-F-2KK
LC2H-F-DL-2KK
LC2H-F-FV-30
LC2H
Input method
Non-voltage input type
Voltage input type (4.5 to 30 V DC)
Free voltage input type (24 to 240 V AC/DC)
Part No.
LC2H-F-DL-2KK-B
Part No.
LC2H-C-2K-N
LC2H-C-30-N
Input method
Voltage input type (4.5 to 30 V DC)
Input method
Non-voltage input type
30 Hz (Note 2)
No
Standard type
Backlight type
Non-voltage input
Voltage input
8 digits
Not required (built-in battery)
2 kHz/30 Hz (Switchable by switch)
16.7 ms
Standard type
Free voltage type
0.25 ms/16.7 ms (Switchable by switch)
—
High level:
24 to 240 V AC/DC
Low level:
0 to 2.4 V AC/DC
Approx. 4.7 kΩ
—
High level: 4.5 to 30 V DC
Low level: 0 to 2 V DC
—
200 ms
73
Non-voltage input using
Non-voltage input using
High
level:
4.5
to
30
V
DC
contacts or open collector
contacts or open collector
Low level: 0 to 2 V DC
connection
connection
When shorted:
When shorted:
Max. 10 kΩ
Max. 10 kΩ
Appox.
4.7
kΩ
When open:
When open:
Max. 750 kΩ
Max. 750 kΩ
Max 0.5 V
—
Max. 0.5 V
7-segment LCD
7-segment LCD
7-segment LCD
With
green/red
backlight
Between charged and
Between charged and uncharged parts: 1,000 V AC for 1 minute.
uncharged parts: 2,000 V
AC for 1 minute.
Min. 100 MΩ (measured at 500 V DC) Measurement location same as for break down voltage.
—
24 V DC (±10%)
—
IEC Standard IP66 (only panel front: when using rubber gasket)
Rubber gasket, mounting bracket
7 years (at 25°C 77°F) Note 1
6 years (at 25°C 77°F)
When shorted:
Max. 10 kΩ
When open:
Max. 750 kΩ
Max. 0.5 V
Non-voltage input using
contacts or open collector
connection
Counting speed
2 kHz
30 Hz
2. PC board mounting type
8 digits
SPECIFICATIONS
1. Panel mounting type
Input impedance
Input method (signal)
Residual voltage
Min. input signal width
Input impedance
Input method (signal)
Type
Item
No. digits
External power supply
Max. counting speed
Min. input signal width
(ON: OFF = 1:1)
Count
input
Reset
input
Residual voltage
Display method
Breakdown voltage (initial)
Insulation resistance (initial)
Backlight power
Protective construction (Note 3)
Accessories (Note 3)
Battery life
Notes) 1. The value given for battery life is calculated based on continuous operation (count input signal ON/OFF = 1:1), therefore, this value is not guaranteed.
Also, battery life is decreased 30% when operation is continuous with 2 kHz count inputting in 2 kHz mode.
2. Operation is at 25 Hz when using 24 V AC.
3. Only for installation frame type.
07/2004
LC2H
2. PC board mounting type
Input impedance
Type
Residual voltage
Min. input signal width
Input method
Input impedance
Type
Item
Input method
No. digits
Rated operation voltage
Allowable operation voltage range
Current consumption
Max. counting speed
Min. input signal width
(ON: OFF = 1:1)
Input method
Count
input
Reset
input
Residual power
Break down voltage (initial)
Insulation resistance (initial)
3. Common
Item
Functional
Vibration resistance
Destructive
Functional
Shock resistance
Destructive
Operation temperature
Storage temperature
Ambient humidity
PART NAMES
2 kHz
0.25 ms
PC board mounting type
Non DC voltage input
8 digits
3 V DC
2.7 to 3.3 V DC
Max. 30 μA (max. 250 μA during reset input)
Panel mounting/PC board mounting types
LC2H
Count speed switch
30 Hz
16.7 ms
OFF❇
Non-voltage input/voltage input
(Terminal block side)
ON
—
(Fixed at 30 Hz)
(LCD side)
2k Hz
30Hz❇
Lock switch
Non-voltage input using contacts or open collector connection
When shorted: Max. 10 kΩ
When open: Max. 750 kΩ
Max. 0.5 V
10 ms
Non-voltage input using contacts or open collector connection
When shorted: Max. 10 kΩ
When open: Max. 750 kΩ
Max. 0.5 V
Between charged and uncharged parts: 1,000 V AC for 1 minute.
Min. 100 MΩ (measured at 500 V DC) Measurement location same as for break down voltage.
COUNTER
RESET
Front reset button
Lock switch
(Unit display 1)
(Terminal block side)
(LCD side)
Notes) 1. ❇Default setting when shipped.
2. Make the switch setting before installing to panel.
Count speed
switch
(Unit display 2)
Free voltage input
10 to 55 Hz (1 cycle/min.), single amplitude: 0.15 mm .006 inch (10 min. on 3 axes)
10 to 55 Hz (1 cycle/min.), single amplitude: 0.375 mm .015 inch (1 hr. on 3 axes)
Min. 98 m/s2 (4 times on 3 axes)
Min. 294 m/s2 (5 times on 3 axes)
–10 to +55°C +14 to +131°F (without frost or dew)
–25 to +65°C –13 to +149°F (without frost or dew)
35 to 85% RH
1. Front reset button
This button resets the count value. It does
not work when the lock switch is ON. Be
aware that battery life will decrease if this
switch is used frequently.
2. Lock switch (Refer to chart on right.)
Disable the front reset button.
Note) Turn ON at the LCD side (reset disabled) and
OFF at the terminal block side (reset enabled).
3. Count speed switch (Refer to chart
on right.)
Use this switch to switch the count speed
between 30 Hz and 2 kHz. (On the nonvoltage and voltage input types, 30 Hz is
on the LCD side and 2 kHz is on the terminal block side. Fixed at 30 Hz for free
voltage input type.)
Note) You must press the front reset button when you
change the count speed switch setting.
74
07/2004
Dimensions
10.4
.409
(44)
(1.732)
1. Panel mounting type
• External dimensions
1) One-touch installation type
22
.866
• Panel installation diagram
Panel (1 to 4.5mm
.039 to .177inch
thickness)
4
54.4
2.142
5
.197
24
.945
7
.276
Rubber spacer
45+0.5
0
1.772+.020
0
Reset input
COUNTER
RESET
22.2+0.5
0
.874+.020
0
44.8
1.764
48
1.890
LC2H
Reset button
1
2
10.4
.409
44
1.732
2) Installation frame type
22
.866
• Panel installation diagram
Installation screws
(found on mounting bracket)
37
1.457
44.8
1.764
48
1.890
LC2H
LC2H
mm inch
General tolerance: ±1.0 ±.039
54.4
2.142
5
.197
COUNTER
RESET
Reset button
Rubber gasket
ATH3804 (included)
Mounting bracket
ATH3803 (included)
24
.945
7
.276
Panel
(1 to 4.5mm .039 to .177inch thickness)
22.2+0.5
0
.874+.020
0
A
A=(48×n-2.5)+1.0
0
A=(1.890×n-.098)+.039
0
• When installing repeatedly (sealed installation)
(Only mounting bracket installation type.)
Reset input
+V
4
0V
1
2
3
4
Reset input
Free voltage input type
Count input
or
75
Notes) 1. Suitable installation panel thickness is 1 to 4.5 mm .039 to .177 inch.
2. Waterproofing will be lost when installing repeatedly (sealed installation).
3
Voltage input type
Note) When installing to a 4.5 mm .177 inch thick panel, remove the rubber spacer
first.
• Panel cut-out dimensions
3
0V
Count input
+V
The standard panel cut-out is shown below.
Use the mounting bracket (ATH3803) and the rubber packing (ATH3804).
(Only mounting bracket installation type.)
60 min.
2.362 min.
2
Non voltage input type
• Terminal layout and wiring diagrams
1) Standard type
Count input
1
Q-R are connected internally.
07/2004
LC2H
2) Backlight type
1
Count input
+V
0V
2
5
6
3
33.02±0.3
1.300±.012
19
.748
4
Reset
input
Count
input
1
2
5
6
0.3±0.1
.012±.004
Reset input
2
3
4
3
4
1
2
6
5
Count
input
4
2.54
.100
5.08
.200
5.08
.200
33.02
1.300
17
3
26
1
28
Count
input
14
15
12
17
3
26
1
28
3V DC
Reset
input
General tolerance: ±1.0 ±.039 mm inch
1.9
.075
15.24 Connection sockets
.600 28 pin DIP terminal
1.9
5.19 .075
.204
Mounting area
PC board pattern (BOTTOM VIEW)
2.54
.100
12
Reset
input
PC board mounting type
Transistor input
NPN transistor
14
3V DC
15
Contact input
5.19
.204
8-0.8 dia.
8-.031 dia.
+V
3
0V
Backlight
0V
Reset
input
Non-voltage input type
15.24±0.3
.600±.012
0.5±0.3
.020±.012
1
0V
+V
Voltage input type
3
26 28
17.3
.681
DIP switch × 8
5.08±0.3
.200±.012
0V
Reset input
+V
4
2. PC board mounting type
• External dimensions
5.08±0.3
.200±.012
0.6±0.1
.024±.004
3.3±0.3
.130±.012
43.4
1.709
LC2H
COUNTER
15 17
1
14 12
• Terminal layout and wiring diagrams
Count input
3
Transistor input
NPN transistor
Q-E, }-w, e-t and S-F are connected internally.
2
0V
(W and R are connected internally.)
Panel mounting type
INPUT METHOD
1
Contact input
1. Standard type
Count
input
(W and R are connected internally.)
3
4
Contact input
2
Reset
input
+V
2
3
4
NPN transistor
1
+V
Transistor input
+V
Reset
input
Voltage input type
Count
input
1
2
3
4
PNP transistor
Count
input
+V
Reset
input
or
1
2
3
4
Free voltage input type
or
or
Notes) 1. When using contact input, since current flow is small from terminals 1 and 3 on the panel mounting type and terminals e to t and S to F on the PC board
mounting type, please use relays and switches with high contact reliability.
2. When using transistor input, use the following as a guide for which transistors (Tr) to use for inputting. (Collector withstand voltage Q 50 V, leakage current < 1 μA)
Count
input
1
Reset input
76
07/2004
Notes) 1. 2 and 4. (The input and reset circuits are functionally insulated.)
2. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 μA)
3. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input
terminal, can cause damage to the internal elements.
Count input
2
6
5
3
4
Contact input
2. Backlight type
Count
input
1
Reset
input
0V
Count
input
2
5
3
4
+V
NPN transistor
Voltage input type
+V
1
6
+V
Transistor input
Reset
input
0V
Count input
Reset input
Count value
1
2
6
5
3
4
PNP transistor
Count
input
1
mm2). When using 2 kHz mode, use with
a wiring floating capacitance of 120 pF (3
m 9.843 ft. for parallel wires of 2 mm2). In
particular, when using shielded wiring, be
careful of the capacitance between wires.
PC board mounting type
1) For external power supply use manganese dioxide or lithium batteries (CR type:
3V).
2) Always reset after external power is applied and confirm that the display reads
“0”.
3) Make the wiring from the battery to the
counter unit as short as absolutely possible. Also, be careful of polarity.
4) Calculate battery life with the following
formula.
t = A/I
t: battery life [h]
I: LC2H current consumption [mA]
A: battery capacity until minimum
operation voltage is reached
[mAh]
5) Hand solder to the lead terminal. Do not
dip solder. With the tip of the soldering iron
at 300°C 572°F perform soldering within 3
seconds (for 30 to 60 W soldering iron).
2. Voltage input type
1) Be aware that applying more than 30 V
+V
Reset
input
99999999
1
0
4
24V DC
3
1
2
3
4
LC2H
Red
5
6
24V DC
Backlight connection
5
Green
2
6
1
0
❇
1
77
DC to count input terminals 1 and 2, and
reset input terminals 3 and 4 will cause
damage to the internal elements.
2) For external resetting use H level (application of 4.5 to 30 V DC) between reset
terminals 3 and 4 of the rear terminals.
In this case, connect + to terminal 3 and
– to terminal 4. This is the valid polarity;
therefore, the counter will not work if reversed.
3) When wiring, try to keep all the input
lines to the count and reset inputs as short
as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Also,
malfunctions might occur if the floating capacitance of these wires exceeds 500 pF
(10 m 32.808 ft. for parallel wires of 2
mm2).
3. Free voltage input type
1) Use count input terminals 1 and 2 for
free voltage input and reset terminals 3
and 4 for non-voltage input.
2) Be aware that the application of voltage
that exceeds the voltage range of the H
level to the count input terminal, and the
application of voltage to the reset input
terminal, can cause damage to the internal elements.
Note) ❇Count becomes “1” when the reset input is turned OFF while the count signal is being input.
0
Notes) 1. Do not reverse the polarities when connecting the DC voltage for the backlight.
2. 2 and 4. (The input and reset circuits are functionally insulated.)
3. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 μA)
4. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input
terminal, can cause damage to the internal elements.
Explanation of operation
1. Counting takes place when the count
input signal is ON.
2. Counting resumes again when the
count value reaches 99999999 (full scale
value) and then returns to “0” with a new
count input.
3. No measurement takes place when a
reset is input.
1) When reset is ON, resetting takes place
and the count becomes “0”.
2) Press the front reset button when you
want to reset manually (only panel installation type).
Note) Be aware that battery life will decrease if the
count input or reset input are left ON.
Cautions for use
1. Non-voltage input type
For both panel mounting and PC board
mounting types
1) Never apply voltage to the non-voltage
input type. This will damage the internal
elements. Also, since there is a possibility
of erroneous operation, do not connect in
parallel the inputs of a non-voltage input
type and another counter from a single input signal.
2) Since the current flow is very small from
the count input and reset input terminals
(1 and 3 on the panel mounting type
and terminals e to t and S to F on the
PC board mounting type) please use relays and switches with high contact reliability.
3) When inputting with an open collector
of a transistor, use a transistor for small
signals in which ICBO is 1 μA or less and
always input with no voltage.
4) When wiring, try to keep all the input
lines to the count and reset inputs as short
as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Also,
malfunctions might occur if the floating capacitance of these wires exceeds 500 pF
(10 m 32.808 ft. for parallel wires of 2
07/2004
LC2H
3 4
D
3 4
D
3 4
Tr
or
3) Since the current flow is very small from
reset input terminal 3, please use relays
and switches with high contact reliability.
4) When inputting a reset with an open
collector of a transistor, use a transistor
for small signals in which ICBO is 1 μA or
less and always input with no voltage.
5) To reset externally, short reset input terminals 3 and 4 on the rear.
6) Input uses a high impedance circuit;
therefore, erroneous operation may occur
if the influence of induction voltage is
present. If you plan to use wiring for the input signal that is 10 m or longer (wire capacitance 120 pF/m at normal
temperature), we recommend the use of a
CR filter or the connection of a bleeder resistor.
4. How to reset multiple panel mounting type counters all at once (input is
the same for count)
Non-voltage input type
D
3 4
R
Tr
+V
or
3 4
+V
Notes) 1. Use the following as a guide for choosing
transistors used for input (Tr).
Leakage current < 1 μA
2. Use as small a diode (D) as possible in the
forward voltage so that the voltage between
terminals 3 and 4 during reset input meets
the standard value (0.5 V).
( At IF = 20 μA, forward voltage 0.1 and
higher.)
3 4
Voltage input type
3 4
Note) Make sure that H (reset ON) level is at least 4.5
V.
2
5
2
5
2
6
Red
2
6
24V DC
5. Backlight luminance
To prevent varying luminance among
backlights when using multiple Backlight
types, please use the same backlight
power supply.
24V DC
Green
6. Insulation sheet
Before using a panel mounting type,
please pull and remove the insulation
sheet from the side of the product in the
direction of the arrow.
In consideration that the product might be
stored for long periods without being
used, an insulation sheet is inserted before shipping. Remove the insulation
sheet and press the front reset button.
78
07/2004