LC2H.fm Seite 68 Mittwoch, 29. Mai 2002 4:46 16
LC2H
DIN HALF SIZE
LCD COUNTER
LC2H
Features
1. 8.7 mm .343 inch Character Height
(previously 7 mm)
Easy-to-read character height increased
from 7 mm to 8.7 mm .276 inch to .343
inch.
Panel mounting type
One-touch installation type
8.7mm
.343inch
2. Plenty of Digits
8 digits
3. Counting Speed Switchable between
2 kHz and 30 Hz
4. Panel Mounting Type Features 2 Installation Methods
Comes with very easy one-touch installation type and also installation frame type
that uses the bracket on the timer/counter.
Choose a method that suits the application.
Panel mounting type
Installation frame type
PC board mounting type
5. Battery Replacement Easy on Environment
To replace battery simply remove body for
the one-touch installation type, and remove battery lid for the installation frame
type.
6. Screw Terminals Designed for Safety
Built in finger protection.
7. Panel Covers Replacable
(Standard color is ash gray.)
Change the panel design by replacing
with a black panel cover.
8. Conforms to IP66 Protective Construction (Only installation frame
type.) (Front panel surface)
9. Input Methods
1) Non-voltage input method
2) Voltage input method
3) Free voltage input method
10. Backlight Type Added to Series and
Now 2-color Switchable (green/red)
Easy viewing even in dark places and
switchable between green and red (Voltage input type).
11. Conforms to Safety Regulations
Product chart
Type
Non-voltage input type
Standard type
Voltage input type
(4.5 to 30 V DC)
Free voltage input type
(24 to 240 V AC/DC)
Backlight type
Voltage input type
(4.5 to 30 V DC)
One-touch installation type
Installation frame type
—
—
—
Installation type
Panel
mounting
type
PC board mounting type
Product types
1. Panel mounting type
1) One-touch installation type
1 Standard type
No. digits
8 digits
Counting speed
2 kHz/30 Hz switchable
Front reset
Yes
30 Hz
Input method
Non-voltage input type
Voltage input type (4.5 to 30 V DC)
Part No.
LC2H-FE-2KK
LC2H-FE-DL-2KK
Free voltage input type (24 to 240 V AC/DC)
LC2H-FE-FV-30
Input method
Voltage input type (4.5 to 30 V DC)
Part No.
LC2H-FE-DL-2KK-B
Note) Please ask us about types without front resetting.
2 Backlight type
No. digits
8 digits
Counting speed
2 kHz/30 Hz switchable
Front reset
Yes
68
02/2003
LC2H.fm Seite 69 Samstag, 23. März 2002 4:15 16
LC2H
2) Installation frame type
1 Standard type
No. digits
8 digits
Counting speed
Front reset
2 kHz/30 Hz switchable
Yes
30 Hz
Input method
Non-voltage input type
Voltage input type (4.5 to 30 V DC)
Free voltage input type (24 to 240 V AC/DC)
Part No.
LC2H-F-2KK
LC2H-F-DL-2KK
LC2H-F-FV-30
Input method
Voltage input type (4.5 to 30 V DC)
Part No.
LC2H-F-DL-2KK-B
Note) Please ask us about types without front resetting.
2 Backlight type
No. digits
8 digits
Counting speed
2 kHz/30 Hz switchable
Front reset
Yes
2. PC board mounting type
No. digits
8 digits
Counting speed
2 kHz
30 Hz
Front reset
No
Input method
Non-voltage input type
Part No.
LC2H-C-2K-N
LC2H-C-30-N
Specifications
1. Panel mounting type
Type
Item
No. digits
External power supply
Max. counting speed
Min. input signal width
(ON: OFF = 1:1)
Input method (signal)
Count
input
Input impedance
Residual voltage
Min. input signal width
Input method (signal)
Reset
input
Input impedance
Residual voltage
Display method
Breakdown voltage (initial)
Insulation resistance (initial)
Backlight power
Protective construction (Note 3)
Accessories (Note 3)
Battery life
Standard type
Non-voltage input
Backlight type
Voltage input
8 digits
Not required (built-in battery)
2 kHz/30 Hz (Switchable by switch)
0.25 ms/16.7 ms (Switchable by switch)
Non-voltage input using
contacts or open collector
connection
High level: 4.5 to 30 V DC
Low level: 0 to 2 V DC
When shorted:
Max. 10 k
When open:
Max. 750 k
Max. 0.5 V
Non-voltage input using
contacts or open collector
connection
When shorted:
Max. 10 k
When open:
Max. 750 k
Max 0.5 V
30 Hz (Note 2)
16.7 ms
High level:
24 to 240 V AC/DC
Low level:
0 to 2.4 V AC/DC
Approx. 4.7 k
—
—
200 ms
—
High level: 4.5 to 30 V DC
Low level: 0 to 2 V DC
Appox. 4.7 k
—
7-segment LCD
Standard type
Free voltage type
7-segment LCD
With green/red backlight
Non-voltage input using
contacts or open collector
connection
When shorted:
Max. 10 k
When open:
Max. 750 k
Max. 0.5 V
7-segment LCD
Between charged and
uncharged parts: 2,000 V
AC for 1 minute.
Min. 100 M (measured at 500 V DC) Measurement location same as for break down voltage.
—
24 V DC (±10%)
—
IEC Standard IP66 (only panel front: when using rubber gasket)
Rubber gasket, mounting bracket
7 years (at 25°C 77°F) Note 1
6 years (at 25°C 77°F)
Between charged and uncharged parts: 1,000 V AC for 1 minute.
Notes) 1. The value given for battery life is calculated based on continuous operation (count input signal ON/OFF = 1:1), therefore, this value is not guaranteed.
Also, battery life is decreased 30% when operation is continuous with 2 kHz count inputting in 2 kHz mode.
2. Operation is at 25 Hz when using 24 V AC.
3. Only for installation frame type.
69
02/2003
LC2H.fm Seite 70 Samstag, 23. März 2002 4:15 16
LC2H
2. PC board mounting type
Type
Item
Input method
No. digits
Rated operation voltage
Allowable operation voltage range
Current consumption
Max. counting speed
Min. input signal width
(ON: OFF = 1:1)
Count Input method
input
Input impedance
Reset
input
Residual voltage
Min. input signal width
Input method
Input impedance
Residual power
Break down voltage (initial)
Insulation resistance (initial)
PC board mounting type
Non DC voltage input
8 digits
3 V DC
2.7 to 3.3 V DC
Max. 30 µA (max. 250 µA during reset input)
2 kHz
30 Hz
0.25 ms
16.7 ms
Non-voltage input using contacts or open collector connection
When shorted: Max. 10 k
When open: Max. 750 k
Max. 0.5 V
10 ms
Non-voltage input using contacts or open collector connection
When shorted: Max. 10 k
When open: Max. 750 k
Max. 0.5 V
Between charged and uncharged parts: 1,000 V AC for 1 minute.
Min. 100 M (measured at 500 V DC) Measurement location same as for break down voltage.
3. Common
Type
Panel mounting/PC board mounting types
Item
Functional
Destructive
Functional
Shock resistance
Destructive
Operation temperature
Storage temperature
Ambient humidity
Vibrationresistance
10 to 55 Hz (1 cycle/min.), single amplitude: 0.15 mm .006 inch (10 min. on 3 axes)
10 to 55 Hz (1 cycle/min.), single amplitude: 0.375 mm .015 inch (1 hr. on 3 axes)
Min. 98 m/s2 (4 times on 3 axes)
Min. 294 m/s2 (5 times on 3 axes)
–10 to +55°C +14 to +131°F (without frost or dew)
–25 to +65°C –13 to +149°F (without frost or dew)
35 to 85% RH
Part names
1. Front reset button
This button resets the count value. It does
not work when the lock switch is ON. Be
aware that battery life will decrease if this
switch is used frequently.
2. Lock switch (Refer to chart on right.)
Disable the front reset button.
COUNTER
Count speed switch
LC2H
RESET
Front reset button
Note) Turn ON at the LCD side (reset disabled) and
OFF at the terminal block side (reset enabled).
3. Count speed switch (Refer to chart
on right.)
Use this switch to switch the count speed
between 30 Hz and 2 kHz. (On the nonvoltage and voltage input types, 30 Hz is
on the LCD side and 2 kHz is on the terminal block side. Fixed at 30 Hz for free
voltage input type.)
Lock switch
Non-voltage input/voltage input
Free voltage input
(Terminal block side)
OFF❇
(LCD side)
ON
Lock switch
(Unit display 1)
Note) You must press the front reset button when you
change the count speed switch setting.
(Terminal block side)
2k Hz
Count speed
switch
(Unit display 2)
—
(LCD side)
30Hz❇
Notes) 1. ❇Default setting when shipped.
2. Make the switch setting before installing to panel.
70
02/2003
(Fixed at 30 Hz)
LC2H.fm Seite 71 Samstag, 23. März 2002 4:15 16
LC2H
Dimensions
mm inch
General tolerance: ±1.0 ±.039
1. Panel mounting type
• External dimensions
1) One-touch installation type
2) Installation frame type
44.8
1.764
44.8
1.764
54.4
2.142
54.4
2.142
10.4
.409
(44)
(1.732)
5
.197
COUNTER
22
.866
10.4
.409
48
1.890
24
.945
5
.197
48
1.890
LC2H
LC2H
COUNTER
22
.866
RESET
7
.276
44
1.732
24
.945
RESET
7
.276
Reset button
Reset button
• Panel installation diagram
• Panel installation diagram
Mounting bracket
ATH3803 (included)
Installation screws
(found on mounting bracket)
37
1.457
Panel (1 to 4.5mm
.039 to .177inch
thickness)
Rubber spacer
Note) When installing to a 4.5 mm .177 inch thick panel, remove the rubber spacer
first.
Rubber gasket
ATH3804 (included)
Panel
(1 to 4.5mm .039 to .177inch thickness)
• Panel cut-out dimensions
• When installing repeatedly (sealed installation)
(Only mounting bracket installation type.)
The standard panel cut-out is shown below.
Use the mounting bracket (ATH3803) and the rubber packing (ATH3804).
(Only mounting bracket installation type.)
22.2+0.5
0
.874+.020
0
A
A=(48×n-2.5)+1.0
0
A=(1.890×n-.098)+.039
0
60 min.
2.362 min.
45+0.5
0
1.772+.020
0
Notes) 1. Suitable installation panel thickness is 1 to 4.5 mm .039 to .177 inch.
2. Waterproofing will be lost when installing repeatedly (sealed installation).
22.2+0.5
0
.874+.020
0
• Terminal layout and wiring diagrams
1) Standard type
Non voltage input type
Count input
Reset input
1
2
3
Voltage input type
Count input
+V
1
4
Free voltage input type
Reset input
+V
2
0V
3
4
Count input
or
Reset input
1
2
3
4
0V
Q-R are connected internally.
71
02/2003
LC2H.fm Seite 72 Samstag, 23. März 2002 4:15 16
LC2H
2) Backlight type
Voltage input type
Count input
+V
0V
+V
Reset input
+V
5
1
2
Backlight
5
3
4
1
2
5
3
6
4
1
6
0V
2
3
4
6
0V
0V
+V
2. PC board mounting type
• External dimensions
PC board pattern (BOTTOM VIEW)
33.02±0.3
1.300±.012
5.08±0.3
.200±.012
0.6±0.1
.024±.004
General tolerance: ±1.0 ±.039 mm inch
5.08±0.3
.200±.012
Mounting area
2.54
.100
DIP switch × 8
1.9
.075
2.54
.100
3.3±0.3
.130±.012
15.24 Connection sockets
.600 28 pin DIP terminal
8-0.8 dia.
8-.031 dia.
43.4
1.709
0.5±0.3
.020±.012
17.3
.681
LC2H
COUNTER
5.19
.204
15.24±0.3
.600±.012
19
.748
1.9
5.19 .075
.204
5.08
.200
5.08
.200
33.02
1.300
0.3±0.1
.012±.004
• Terminal layout and wiring diagrams
Count input
15 17
26 28
14 12
3
Reset input
1
Q-E, }-w, e-t and S-F are connected internally.
Input method
1. Standard type
Non-voltage input type
Panel mounting type
PC board mounting type
Transistor input
Transistor input
Contact input
Contact input
NPN transistor
NPN transistor
Count
input
1
2
3
4
Reset
input
Count
input
1
2
3
Reset
input
4
0V
(W and R are connected internally.)
Count
input
15
17
26
28
14
12
3
1
Reset
input
Count
input
15
17
26
28
14
12
3
1
Reset
input
0V
(W and R are connected internally.)
3V DC
3V DC
Notes) 1. When using contact input, since current flow is small from terminals 1 and 3 on the panel mounting type and terminals e to t and S to F on the PC board
mounting type, please use relays and switches with high contact reliability.
2. When using transistor input, use the following as a guide for which transistors (Tr) to use for inputting. (Collector withstand voltage Q 50 V, leakage current < 1 µA)
Voltage input type
Transistor input
+V
Count
input
Reset
input
1
2
3
4
+V
Count
input
1
2
3
4
Free voltage input type
PNP transistor
+V
Reset
input
+V
Count
input
1
2
3
4
Reset
input
1
or
or
2
3
4
or
Reset input
NPN transistor
Count input
Contact input
Notes) 1. 2 and 4. (The input and reset circuits are functionally insulated.)
2. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 µA)
3. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input
terminal, can cause damage to the internal elements.
72
02/2003
LC2H.fm Seite 73 Samstag, 23. März 2002 4:15 16
LC2H
2. Backlight type
Voltage input type
Transistor input
Contact input
+V
Count
input
Backlight connection
NPN transistor
PNP transistor
+V
+V
Green
+V
5
1
2
3
4
6
Red
24V DC
Reset
input
Count
input
0V
5
1
2
3
6
4
Count
input
Reset
input
5
1
2
3
6
4
Reset
input
5
1
2
6
5
3
1
4
2
0V
6
3
4
24V DC
Notes) 1. Do not reverse the polarities when connecting the DC voltage for the backlight.
2. 2 and 4. (The input and reset circuits are functionally insulated.)
3. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 µA)
4. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input
terminal, can cause damage to the internal elements.
Explanation of operation
1. Counting takes place when the count
input signal is ON.
2. Counting resumes again when the
count value reaches 99999999 (full scale
value) and then returns to “0” with a new
count input.
3. No measurement takes place when a
reset is input.
1) When reset is ON, resetting takes place
and the count becomes “0”.
2) Press the front reset button when you
want to reset manually (only panel installation type).
Count input
❇
Reset input
Count value
0
1
99999999
0
1
0
1
Note) ❇Count becomes “1” when the reset input is turned OFF while the count signal is being input.
Note) Be aware that battery life will decrease if the
count input or reset input are left ON.
Cautions for use
1. Non-voltage input type
For both panel mounting and PC board
mounting types
1) Never apply voltage to the non-voltage
input type. This will damage the internal
elements. Also, since there is a possibility
of erroneous operation, do not connect in
parallel the inputs of a non-voltage input
type and another counter from a single input signal.
2) Since the current flow is very small from
the count input and reset input terminals
(1 and 3 on the panel mounting type
and terminals e to t and S to F on the
PC board mounting type) please use relays and switches with high contact reliability.
3) When inputting with an open collector
of a transistor, use a transistor for small
signals in which ICBO is 1 µA or less and
always input with no voltage.
4) When wiring, try to keep all the input
lines to the count and reset inputs as short
as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Also,
malfunctions might occur if the floating capacitance of these wires exceeds 500 pF
(10 m 32.808 ft. for parallel wires of 2
mm2). When using 2 kHz mode, use with
a wiring floating capacitance of 120 pF (3
m 9.843 ft. for parallel wires of 2 mm2). In
particular, when using shielded wiring, be
careful of the capacitance between wires.
PC board mounting type
1) For external power supply use manganese dioxide or lithium batteries (CR type:
3V).
2) Always reset after external power is applied and confirm that the display reads
“0”.
3) Make the wiring from the battery to the
counter unit as short as absolutely possible. Also, be careful of polarity.
4) Calculate battery life with the following
formula.
t = A/I
t: battery life [h]
I: LC2H current consumption [mA]
A: battery capacity until minimum
operation voltage is reached
[mAh]
5) Hand solder to the lead terminal. Do not
dip solder. With the tip of the soldering iron
at 300°C 572°F perform soldering within 3
seconds (for 30 to 60 W soldering iron).
2. Voltage input type
1) Be aware that applying more than 30 V
DC to count input terminals 1 and 2, and
reset input terminals 3 and 4 will cause
damage to the internal elements.
2) For external resetting use H level (application of 4.5 to 30 V DC) between reset
terminals 3 and 4 of the rear terminals.
In this case, connect + to terminal 3 and
– to terminal 4. This is the valid polarity;
therefore, the counter will not work if reversed.
3) When wiring, try to keep all the input
lines to the count and reset inputs as short
as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Also,
malfunctions might occur if the floating capacitance of these wires exceeds 500 pF
(10 m 32.808 ft. for parallel wires of 2
mm2).
3. Free voltage input type
1) Use count input terminals 1 and 2 for
free voltage input and reset terminals 3
and 4 for non-voltage input.
2) Be aware that the application of voltage
that exceeds the voltage range of the H
level to the count input terminal, and the
application of voltage to the reset input
terminal, can cause damage to the internal elements.
73
02/2003
LC2H.fm Seite 74 Samstag, 23. März 2002 4:15 16
LC2H
3) Since the current flow is very small from
reset input terminal 3, please use relays
and switches with high contact reliability.
4) When inputting a reset with an open
collector of a transistor, use a transistor
for small signals in which ICBO is 1 µA or
less and always input with no voltage.
5) To reset externally, short reset input terminals 3 and 4 on the rear.
6) Input uses a high impedance circuit;
therefore, erroneous operation may occur
if the influence of induction voltage is
present. If you plan to use wiring for the input signal that is 10 m or longer (wire capacitance 120 pF/m at normal
temperature), we recommend the use of a
CR filter or the connection of a bleeder resistor.
4. How to reset multiple panel mounting type counters all at once (input is
the same for count)
Non-voltage input type
D
D
3 4
D
3 4
Tr
or
3 4
Notes) 1. Use the following as a guide for choosing
transistors used for input (Tr).
Leakage current < 1 µA
2. Use as small a diode (D) as possible in the
forward voltage so that the voltage between
terminals 3 and 4 during reset input meets
the standard value (0.5 V).
( At IF = 20 µA, forward voltage 0.1 and
higher.)
Voltage input type
R
Tr
3 4
3 4
+V
+V
or
3 4
One-touch installation type
Reset button
Insulation sheet
Installation frame type
Insulation sheet
Reset button
7. Waterproof construction (Installation frame type)
The operation part of the panel installation type (Installation frame type) is constructed to prevent water from entering
the unit and a rubber gasket is provided to
prevent water from entering the gap between the unit and the panel cutout. There
must be sufficient pressure applied to the
rubber gasket to prevent water from entering. Be sure to use the installation reinforcement screws when installing the
frame (ATH3803).
Note) Make sure that H (reset ON) level is at least 4.5
V.
Tool
1
Note) The one-touch installation type is not
waterproof.
8. Do not use in the following environments
3 4
ganic solvents such as methyl alcohol,
benzene and thinner, or strong alkali substances such as ammonia and caustic soda.
10. Cautions regarding battery replacement
1) Remove wiring before replacing the
battery. You may be electrocuted if you
come into contact to a part where high
voltage is applied.
2) Make sure you are not carrying a static
electric charge when replacing the battery.
3) Battery replacement procedure
1 One-touch installation type
1. Using a tool remove the up/down hook
of the case.
2. Pull the unit away from the case.
3. Remove the battery from the side of the
unit. Do not touch the display or other
parts.
4. Before inserting wipe clean the surface
of the battery.
5. Insert the battery with the + and – sides
in the proper position.
6. After replacing the battery return the
unit to the case. Verify that the hook of the
case has properly engaged.
7. Before using press the reset button on
the front.
2
Frame (ATH3803)
5. Backlight luminance
To prevent varying luminance among
backlights when using multiple Backlight
types, please use the same backlight
power supply.
24V DC
2
5
2
Green
5
2
2
6
6
24V DC
Red
6. Insulation sheet
Before using a panel mounting type,
please pull and remove the insulation
sheet from the side of the product in the
direction of the arrow.
In consideration that the product might be
stored for long periods without being
used, an insulation sheet is inserted before shipping. Remove the insulation
sheet and press the front reset button.
1
1) In places where the temperature
changes drastically.
2) In places where humidity is high and
there is the possibility of dew. (When dew
forms the display may vanish and other
display errors may occur.)
9. Conditions of use
1) Do not use in places where there is
flammable or corrosive gas, lots of dust,
presence of oil, or where the unit might be
subject to strong vibrations or shocks.
2) Since the cover is made of polycarbonate resin, do not use in places where the
unit might come into contact with or be exposed to environments that contain or-
74
02/2003
3
6
7
LC2H.fm Seite 75 Samstag, 23. März 2002 4:15 16
LC2H
2 Installation frame type
1. Remove the battery cover 1 from the
case.
2. Remove the battery 2 from the side of
the case. The battery will come loose if
you put the battery side face down and
lightly shake the unit
3. Before inserting wipe clean the surface
of the battery.
4. Insert the battery with the + and – sides
in the proper position.
5. After replacing the battery return the
battery cover to the case 5. Verify that the
hook of the battery cover is properly engaged.
6. Before using press the reset button 6
on the front.
1
2
+ side
5
− side
6
Options
2. Lithium battery (3 V)
1. Accessaries
Panel cover (black)
COUNTER
Pa
CR2n4asonic
77
3V
JAPA
N
3. Installation parts
Mounting bracket (suitable for installation frame type)
LC2H
RESET
Part No.: AEL3801
You can change the design of the front
panel by replacing it with this black panel
cover. The counter comes with an ash
gray panel cover as standard.
Part No.: ATH3802
Comes packaged with the LC2H (excluding the PC board mounting type).
Warning
• Make sure the + and − polarities are
positioned correctly.
• Do not throw the old battery into a fire,
short circuit it, take it apart, or allow it to
come into contact with heat.
• The battery is not rechargeable.
Part No.: ATH3803
Packaged with LC2H (panel mounting
type installation frame type).
Rubber gasket (suitable for installation
frame type)
Part No.: ATH3804
Packaged with LC2H (panel mounting
type installation frame type).
75