0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LC2HFE2KKJ

LC2HFE2KKJ

  • 厂商:

    NAIS(松下)

  • 封装:

  • 描述:

    PANASONIC - LC2HFE2KKJ - Panel Counter, LCD, 8 Digit, 8 Digit, 8.7 mm Digit, 45 mm x 22.2 mm, LC2H S...

  • 数据手册
  • 价格&库存
LC2HFE2KKJ 数据手册
LC2H.fm Seite 68 Mittwoch, 29. Mai 2002 4:46 16 LC2H DIN HALF SIZE LCD COUNTER LC2H Features 1. 8.7 mm .343 inch Character Height (previously 7 mm) Easy-to-read character height increased from 7 mm to 8.7 mm .276 inch to .343 inch. Panel mounting type One-touch installation type 8.7mm .343inch 2. Plenty of Digits 8 digits 3. Counting Speed Switchable between 2 kHz and 30 Hz 4. Panel Mounting Type Features 2 Installation Methods Comes with very easy one-touch installation type and also installation frame type that uses the bracket on the timer/counter. Choose a method that suits the application. Panel mounting type Installation frame type PC board mounting type 5. Battery Replacement Easy on Environment To replace battery simply remove body for the one-touch installation type, and remove battery lid for the installation frame type. 6. Screw Terminals Designed for Safety Built in finger protection. 7. Panel Covers Replacable (Standard color is ash gray.) Change the panel design by replacing with a black panel cover. 8. Conforms to IP66 Protective Construction (Only installation frame type.) (Front panel surface) 9. Input Methods 1) Non-voltage input method 2) Voltage input method 3) Free voltage input method 10. Backlight Type Added to Series and Now 2-color Switchable (green/red) Easy viewing even in dark places and switchable between green and red (Voltage input type). 11. Conforms to Safety Regulations Product chart Type Non-voltage input type Standard type Voltage input type (4.5 to 30 V DC) Free voltage input type (24 to 240 V AC/DC) Backlight type Voltage input type (4.5 to 30 V DC) One-touch installation type     Installation frame type      — — — Installation type Panel mounting type PC board mounting type Product types 1. Panel mounting type 1) One-touch installation type 1 Standard type No. digits 8 digits Counting speed 2 kHz/30 Hz switchable Front reset Yes 30 Hz Input method Non-voltage input type Voltage input type (4.5 to 30 V DC) Part No. LC2H-FE-2KK LC2H-FE-DL-2KK Free voltage input type (24 to 240 V AC/DC) LC2H-FE-FV-30 Input method Voltage input type (4.5 to 30 V DC) Part No. LC2H-FE-DL-2KK-B Note) Please ask us about types without front resetting. 2 Backlight type No. digits 8 digits Counting speed 2 kHz/30 Hz switchable Front reset Yes 68 02/2003 LC2H.fm Seite 69 Samstag, 23. März 2002 4:15 16 LC2H 2) Installation frame type 1 Standard type No. digits 8 digits Counting speed Front reset 2 kHz/30 Hz switchable Yes 30 Hz Input method Non-voltage input type Voltage input type (4.5 to 30 V DC) Free voltage input type (24 to 240 V AC/DC) Part No. LC2H-F-2KK LC2H-F-DL-2KK LC2H-F-FV-30 Input method Voltage input type (4.5 to 30 V DC) Part No. LC2H-F-DL-2KK-B Note) Please ask us about types without front resetting. 2 Backlight type No. digits 8 digits Counting speed 2 kHz/30 Hz switchable Front reset Yes 2. PC board mounting type No. digits 8 digits Counting speed 2 kHz 30 Hz Front reset No Input method Non-voltage input type Part No. LC2H-C-2K-N LC2H-C-30-N Specifications 1. Panel mounting type Type Item No. digits External power supply Max. counting speed Min. input signal width (ON: OFF = 1:1) Input method (signal) Count input Input impedance Residual voltage Min. input signal width Input method (signal) Reset input Input impedance Residual voltage Display method Breakdown voltage (initial) Insulation resistance (initial) Backlight power Protective construction (Note 3) Accessories (Note 3) Battery life Standard type Non-voltage input Backlight type Voltage input 8 digits Not required (built-in battery) 2 kHz/30 Hz (Switchable by switch) 0.25 ms/16.7 ms (Switchable by switch) Non-voltage input using contacts or open collector connection High level: 4.5 to 30 V DC Low level: 0 to 2 V DC When shorted: Max. 10 k When open: Max. 750 k Max. 0.5 V Non-voltage input using contacts or open collector connection When shorted: Max. 10 k When open: Max. 750 k Max 0.5 V 30 Hz (Note 2) 16.7 ms High level: 24 to 240 V AC/DC Low level: 0 to 2.4 V AC/DC Approx. 4.7 k — — 200 ms — High level: 4.5 to 30 V DC Low level: 0 to 2 V DC Appox. 4.7 k — 7-segment LCD Standard type Free voltage type 7-segment LCD With green/red backlight Non-voltage input using contacts or open collector connection When shorted: Max. 10 k When open: Max. 750 k Max. 0.5 V 7-segment LCD Between charged and uncharged parts: 2,000 V AC for 1 minute. Min. 100 M (measured at 500 V DC) Measurement location same as for break down voltage. — 24 V DC (±10%) — IEC Standard IP66 (only panel front: when using rubber gasket) Rubber gasket, mounting bracket 7 years (at 25°C 77°F) Note 1 6 years (at 25°C 77°F) Between charged and uncharged parts: 1,000 V AC for 1 minute. Notes) 1. The value given for battery life is calculated based on continuous operation (count input signal ON/OFF = 1:1), therefore, this value is not guaranteed. Also, battery life is decreased 30% when operation is continuous with 2 kHz count inputting in 2 kHz mode. 2. Operation is at 25 Hz when using 24 V AC. 3. Only for installation frame type. 69 02/2003 LC2H.fm Seite 70 Samstag, 23. März 2002 4:15 16 LC2H 2. PC board mounting type Type Item Input method No. digits Rated operation voltage Allowable operation voltage range Current consumption Max. counting speed Min. input signal width (ON: OFF = 1:1) Count Input method input Input impedance Reset input Residual voltage Min. input signal width Input method Input impedance Residual power Break down voltage (initial) Insulation resistance (initial) PC board mounting type Non DC voltage input 8 digits 3 V DC 2.7 to 3.3 V DC Max. 30 µA (max. 250 µA during reset input) 2 kHz 30 Hz 0.25 ms 16.7 ms Non-voltage input using contacts or open collector connection When shorted: Max. 10 k When open: Max. 750 k Max. 0.5 V 10 ms Non-voltage input using contacts or open collector connection When shorted: Max. 10 k When open: Max. 750 k Max. 0.5 V Between charged and uncharged parts: 1,000 V AC for 1 minute. Min. 100 M (measured at 500 V DC) Measurement location same as for break down voltage. 3. Common Type Panel mounting/PC board mounting types Item Functional Destructive Functional Shock resistance Destructive Operation temperature Storage temperature Ambient humidity Vibrationresistance 10 to 55 Hz (1 cycle/min.), single amplitude: 0.15 mm .006 inch (10 min. on 3 axes) 10 to 55 Hz (1 cycle/min.), single amplitude: 0.375 mm .015 inch (1 hr. on 3 axes) Min. 98 m/s2 (4 times on 3 axes) Min. 294 m/s2 (5 times on 3 axes) –10 to +55°C +14 to +131°F (without frost or dew) –25 to +65°C –13 to +149°F (without frost or dew) 35 to 85% RH Part names 1. Front reset button This button resets the count value. It does not work when the lock switch is ON. Be aware that battery life will decrease if this switch is used frequently. 2. Lock switch (Refer to chart on right.) Disable the front reset button. COUNTER Count speed switch LC2H RESET Front reset button Note) Turn ON at the LCD side (reset disabled) and OFF at the terminal block side (reset enabled). 3. Count speed switch (Refer to chart on right.) Use this switch to switch the count speed between 30 Hz and 2 kHz. (On the nonvoltage and voltage input types, 30 Hz is on the LCD side and 2 kHz is on the terminal block side. Fixed at 30 Hz for free voltage input type.) Lock switch Non-voltage input/voltage input Free voltage input (Terminal block side) OFF❇ (LCD side) ON Lock switch (Unit display 1) Note) You must press the front reset button when you change the count speed switch setting. (Terminal block side) 2k Hz Count speed switch (Unit display 2) — (LCD side) 30Hz❇ Notes) 1. ❇Default setting when shipped. 2. Make the switch setting before installing to panel. 70 02/2003 (Fixed at 30 Hz) LC2H.fm Seite 71 Samstag, 23. März 2002 4:15 16 LC2H Dimensions mm inch General tolerance: ±1.0 ±.039 1. Panel mounting type • External dimensions 1) One-touch installation type 2) Installation frame type 44.8 1.764 44.8 1.764 54.4 2.142 54.4 2.142 10.4 .409 (44) (1.732) 5 .197 COUNTER 22 .866 10.4 .409 48 1.890 24 .945 5 .197 48 1.890 LC2H LC2H COUNTER 22 .866 RESET 7 .276 44 1.732 24 .945 RESET 7 .276 Reset button Reset button • Panel installation diagram • Panel installation diagram Mounting bracket ATH3803 (included) Installation screws (found on mounting bracket) 37 1.457 Panel (1 to 4.5mm .039 to .177inch thickness) Rubber spacer Note) When installing to a 4.5 mm .177 inch thick panel, remove the rubber spacer first. Rubber gasket ATH3804 (included) Panel (1 to 4.5mm .039 to .177inch thickness) • Panel cut-out dimensions • When installing repeatedly (sealed installation) (Only mounting bracket installation type.) The standard panel cut-out is shown below. Use the mounting bracket (ATH3803) and the rubber packing (ATH3804). (Only mounting bracket installation type.) 22.2+0.5 0 .874+.020 0 A A=(48×n-2.5)+1.0 0 A=(1.890×n-.098)+.039 0 60 min. 2.362 min. 45+0.5 0 1.772+.020 0 Notes) 1. Suitable installation panel thickness is 1 to 4.5 mm .039 to .177 inch. 2. Waterproofing will be lost when installing repeatedly (sealed installation). 22.2+0.5 0 .874+.020 0 • Terminal layout and wiring diagrams 1) Standard type Non voltage input type Count input Reset input 1 2 3 Voltage input type Count input +V 1 4 Free voltage input type Reset input +V 2 0V 3 4 Count input or Reset input 1 2 3 4 0V Q-R are connected internally. 71 02/2003 LC2H.fm Seite 72 Samstag, 23. März 2002 4:15 16 LC2H 2) Backlight type Voltage input type Count input +V 0V +V Reset input +V 5 1 2 Backlight 5 3 4 1 2 5 3 6 4 1 6 0V 2 3 4 6 0V 0V +V 2. PC board mounting type • External dimensions PC board pattern (BOTTOM VIEW) 33.02±0.3 1.300±.012 5.08±0.3 .200±.012 0.6±0.1 .024±.004 General tolerance: ±1.0 ±.039 mm inch 5.08±0.3 .200±.012 Mounting area 2.54 .100 DIP switch × 8 1.9 .075 2.54 .100 3.3±0.3 .130±.012 15.24 Connection sockets .600 28 pin DIP terminal 8-0.8 dia. 8-.031 dia. 43.4 1.709 0.5±0.3 .020±.012 17.3 .681 LC2H COUNTER 5.19 .204 15.24±0.3 .600±.012 19 .748 1.9 5.19 .075 .204 5.08 .200 5.08 .200 33.02 1.300 0.3±0.1 .012±.004 • Terminal layout and wiring diagrams Count input 15 17 26 28 14 12 3 Reset input 1 Q-E, }-w, e-t and S-F are connected internally. Input method 1. Standard type Non-voltage input type Panel mounting type PC board mounting type Transistor input Transistor input Contact input Contact input NPN transistor NPN transistor Count input 1 2 3 4 Reset input Count input 1 2 3 Reset input 4 0V (W and R are connected internally.) Count input 15 17 26 28 14 12 3 1 Reset input Count input 15 17 26 28 14 12 3 1 Reset input 0V (W and R are connected internally.) 3V DC 3V DC Notes) 1. When using contact input, since current flow is small from terminals 1 and 3 on the panel mounting type and terminals e to t and S to F on the PC board mounting type, please use relays and switches with high contact reliability. 2. When using transistor input, use the following as a guide for which transistors (Tr) to use for inputting. (Collector withstand voltage Q 50 V, leakage current < 1 µA) Voltage input type Transistor input +V Count input Reset input 1 2 3 4 +V Count input 1 2 3 4 Free voltage input type PNP transistor +V Reset input +V Count input 1 2 3 4 Reset input 1 or or 2 3 4 or Reset input NPN transistor Count input Contact input Notes) 1. 2 and 4. (The input and reset circuits are functionally insulated.) 2. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 µA) 3. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input terminal, can cause damage to the internal elements. 72 02/2003 LC2H.fm Seite 73 Samstag, 23. März 2002 4:15 16 LC2H 2. Backlight type Voltage input type Transistor input Contact input +V Count input Backlight connection NPN transistor PNP transistor +V +V Green +V 5 1 2 3 4 6 Red 24V DC Reset input Count input 0V 5 1 2 3 6 4 Count input Reset input 5 1 2 3 6 4 Reset input 5 1 2 6 5 3 1 4 2 0V 6 3 4 24V DC Notes) 1. Do not reverse the polarities when connecting the DC voltage for the backlight. 2. 2 and 4. (The input and reset circuits are functionally insulated.) 3. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 µA) 4. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input terminal, can cause damage to the internal elements. Explanation of operation 1. Counting takes place when the count input signal is ON. 2. Counting resumes again when the count value reaches 99999999 (full scale value) and then returns to “0” with a new count input. 3. No measurement takes place when a reset is input. 1) When reset is ON, resetting takes place and the count becomes “0”. 2) Press the front reset button when you want to reset manually (only panel installation type). Count input ❇ Reset input Count value 0 1 99999999 0 1 0 1 Note) ❇Count becomes “1” when the reset input is turned OFF while the count signal is being input. Note) Be aware that battery life will decrease if the count input or reset input are left ON. Cautions for use 1. Non-voltage input type For both panel mounting and PC board mounting types 1) Never apply voltage to the non-voltage input type. This will damage the internal elements. Also, since there is a possibility of erroneous operation, do not connect in parallel the inputs of a non-voltage input type and another counter from a single input signal. 2) Since the current flow is very small from the count input and reset input terminals (1 and 3 on the panel mounting type and terminals e to t and S to F on the PC board mounting type) please use relays and switches with high contact reliability. 3) When inputting with an open collector of a transistor, use a transistor for small signals in which ICBO is 1 µA or less and always input with no voltage. 4) When wiring, try to keep all the input lines to the count and reset inputs as short as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Also, malfunctions might occur if the floating capacitance of these wires exceeds 500 pF (10 m 32.808 ft. for parallel wires of 2 mm2). When using 2 kHz mode, use with a wiring floating capacitance of 120 pF (3 m 9.843 ft. for parallel wires of 2 mm2). In particular, when using shielded wiring, be careful of the capacitance between wires. PC board mounting type 1) For external power supply use manganese dioxide or lithium batteries (CR type: 3V). 2) Always reset after external power is applied and confirm that the display reads “0”. 3) Make the wiring from the battery to the counter unit as short as absolutely possible. Also, be careful of polarity. 4) Calculate battery life with the following formula. t = A/I t: battery life [h] I: LC2H current consumption [mA] A: battery capacity until minimum operation voltage is reached [mAh] 5) Hand solder to the lead terminal. Do not dip solder. With the tip of the soldering iron at 300°C 572°F perform soldering within 3 seconds (for 30 to 60 W soldering iron). 2. Voltage input type 1) Be aware that applying more than 30 V DC to count input terminals 1 and 2, and reset input terminals 3 and 4 will cause damage to the internal elements. 2) For external resetting use H level (application of 4.5 to 30 V DC) between reset terminals 3 and 4 of the rear terminals. In this case, connect + to terminal 3 and – to terminal 4. This is the valid polarity; therefore, the counter will not work if reversed. 3) When wiring, try to keep all the input lines to the count and reset inputs as short as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Also, malfunctions might occur if the floating capacitance of these wires exceeds 500 pF (10 m 32.808 ft. for parallel wires of 2 mm2). 3. Free voltage input type 1) Use count input terminals 1 and 2 for free voltage input and reset terminals 3 and 4 for non-voltage input. 2) Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input terminal, can cause damage to the internal elements. 73 02/2003 LC2H.fm Seite 74 Samstag, 23. März 2002 4:15 16 LC2H 3) Since the current flow is very small from reset input terminal 3, please use relays and switches with high contact reliability. 4) When inputting a reset with an open collector of a transistor, use a transistor for small signals in which ICBO is 1 µA or less and always input with no voltage. 5) To reset externally, short reset input terminals 3 and 4 on the rear. 6) Input uses a high impedance circuit; therefore, erroneous operation may occur if the influence of induction voltage is present. If you plan to use wiring for the input signal that is 10 m or longer (wire capacitance 120 pF/m at normal temperature), we recommend the use of a CR filter or the connection of a bleeder resistor. 4. How to reset multiple panel mounting type counters all at once (input is the same for count) Non-voltage input type D D 3 4 D 3 4 Tr or 3 4 Notes) 1. Use the following as a guide for choosing transistors used for input (Tr). Leakage current < 1 µA 2. Use as small a diode (D) as possible in the forward voltage so that the voltage between terminals 3 and 4 during reset input meets the standard value (0.5 V). ( At IF = 20 µA, forward voltage 0.1 and higher.) Voltage input type R Tr 3 4 3 4 +V +V or 3 4 One-touch installation type Reset button Insulation sheet Installation frame type Insulation sheet Reset button 7. Waterproof construction (Installation frame type) The operation part of the panel installation type (Installation frame type) is constructed to prevent water from entering the unit and a rubber gasket is provided to prevent water from entering the gap between the unit and the panel cutout. There must be sufficient pressure applied to the rubber gasket to prevent water from entering. Be sure to use the installation reinforcement screws when installing the frame (ATH3803). Note) Make sure that H (reset ON) level is at least 4.5 V. Tool 1 Note) The one-touch installation type is not waterproof. 8. Do not use in the following environments 3 4 ganic solvents such as methyl alcohol, benzene and thinner, or strong alkali substances such as ammonia and caustic soda. 10. Cautions regarding battery replacement 1) Remove wiring before replacing the battery. You may be electrocuted if you come into contact to a part where high voltage is applied. 2) Make sure you are not carrying a static electric charge when replacing the battery. 3) Battery replacement procedure 1 One-touch installation type 1. Using a tool remove the up/down hook of the case. 2. Pull the unit away from the case. 3. Remove the battery from the side of the unit. Do not touch the display or other parts. 4. Before inserting wipe clean the surface of the battery. 5. Insert the battery with the + and – sides in the proper position. 6. After replacing the battery return the unit to the case. Verify that the hook of the case has properly engaged. 7. Before using press the reset button on the front. 2 Frame (ATH3803) 5. Backlight luminance To prevent varying luminance among backlights when using multiple Backlight types, please use the same backlight power supply. 24V DC 2 5 2 Green 5 2 2 6 6 24V DC Red 6. Insulation sheet Before using a panel mounting type, please pull and remove the insulation sheet from the side of the product in the direction of the arrow. In consideration that the product might be stored for long periods without being used, an insulation sheet is inserted before shipping. Remove the insulation sheet and press the front reset button. 1 1) In places where the temperature changes drastically. 2) In places where humidity is high and there is the possibility of dew. (When dew forms the display may vanish and other display errors may occur.) 9. Conditions of use 1) Do not use in places where there is flammable or corrosive gas, lots of dust, presence of oil, or where the unit might be subject to strong vibrations or shocks. 2) Since the cover is made of polycarbonate resin, do not use in places where the unit might come into contact with or be exposed to environments that contain or- 74 02/2003 3 6 7 LC2H.fm Seite 75 Samstag, 23. März 2002 4:15 16 LC2H 2 Installation frame type 1. Remove the battery cover 1 from the case. 2. Remove the battery 2 from the side of the case. The battery will come loose if you put the battery side face down and lightly shake the unit 3. Before inserting wipe clean the surface of the battery. 4. Insert the battery with the + and – sides in the proper position. 5. After replacing the battery return the battery cover to the case 5. Verify that the hook of the battery cover is properly engaged. 6. Before using press the reset button 6 on the front. 1 2 + side 5 − side 6 Options 2. Lithium battery (3 V) 1. Accessaries Panel cover (black) COUNTER Pa CR2n4asonic 77 3V JAPA N 3. Installation parts Mounting bracket (suitable for installation frame type) LC2H RESET Part No.: AEL3801 You can change the design of the front panel by replacing it with this black panel cover. The counter comes with an ash gray panel cover as standard. Part No.: ATH3802 Comes packaged with the LC2H (excluding the PC board mounting type). Warning • Make sure the + and − polarities are positioned correctly. • Do not throw the old battery into a fire, short circuit it, take it apart, or allow it to come into contact with heat. • The battery is not rechargeable. Part No.: ATH3803 Packaged with LC2H (panel mounting type installation frame type). Rubber gasket (suitable for installation frame type) Part No.: ATH3804 Packaged with LC2H (panel mounting type installation frame type). 75 02/2003
LC2HFE2KKJ 价格&库存

很抱歉,暂时无法提供与“LC2HFE2KKJ”相匹配的价格&库存,您可以联系我们找货

免费人工找货