0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LX-101-P-Z

LX-101-P-Z

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SENSOR REFLECTIVE 10MM PNP

  • 数据手册
  • 价格&库存
LX-101-P-Z 数据手册
899 FIBER SENSORS Digital Mark Sensor Amplifier Built-in LX-100 SERIES Related Information ■■General terms and conditions.............. F-3 ■■Glossary of terms........................ P.1549~ ■■Selection guide...............................P.865~ ■■General precautions.................... P.1552~ LASER SENSORS PHOTOELECTRIC SENSORS Recognition MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS panasonic.net/id/pidsx/global STATIC CONTROL DEVICES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Wafer Detection Ultrasonic Small / Slim Object Detection Obstacle Detection LX-100 FZ-10 Automatic sensitivity setting Can detect any mark! Coaxial reflective optics and a sharp 1 × 5 mm 0.039 × 0.197 in spot enable high precision sensing. Stable detection of marks is possible. Newly developed 4-digit digital display The 4-digit digital display enables numerical sensing control and minute settings. Operation panel R•G•B light emitting elements all in one 3 large buttons that click into position making operation easy. To detect any marking, this unit is blue equipped with red, green and blue light emitting emittingelements elementsallallinin LED light one. Highest in the industry 12-bit A/D converter A resolution of 1/4,000 is realized to enable high precision mark sensing. Total reflection High precision coaxial mirror reflective optical system Panasonic Industrial Devicesreflective SUNX’s SUNX’s unique coaxial optics coaxial technology ensures unique reflective optics very accurate sensing. is made technology ensuresThe veryunit accurate with a scratchproof glass with lens.a sensing. The unit is made scratchproof glass lens. Half mirror Receiving element Glass lens Protection IP67 Washing the machines and production line with water will not affect the sensor thanks to its waterproof construction. Spot size 1 × 5 mm 0.039 × 0.197 in approx. ▲Image schematic Automatic optimal LED selection function The 3 colors of the R•G•B LEDs are optimally selected according to the color combination. With the LX-100’s Mark mode, the built-in “Automatic optimal LED selection function” automatically selects the LED for the largest contrast (S/N ratio) between the mark and base (non-mark area) to ensure optimal sensing. For more stable detection, the sensor makes selection according to the contrast and not according to the reflected light variation between the mark and base (non-mark area). The example on the right deals with reflected light on packing film. Great figures are indicated for the blue LED’s light amount ratio and, for even more stable sensing, the blue LED effectuates this mark sensing. Example: A packing film Mark Light amount = ratio Base 6 : 8 Reflective light HUMAN MACHINE INTERFACES Timer Introduction of the 3 LED mark sensor Reflective light PLC Reflective light LASER MARKERS PNP output type available Mark Light amount = ratio Base 8 : 4 Optimal Mark Light amount = ratio Base 4 : 1 Digital Mark Sensor LX-100 SERIES Two detection modes can be selected from to suit the application Mark mode Ultra high-speed response This sensing mode automatically selects a single color from the 3 R•G•B LEDs to achieve an ultra quick 45 µs response time. The automatic optimal LED selection function automatically selects the LED that is most suitable for the sensing. This function is perfect for ultra quick sensing. RED 900 FIBER SENSORS Automatic selection of the optimal LED LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS GREEN BLUE AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Color mode High precision discrimination SIMPLE WIRE-SAVING UNITS All 3 R•G•B LEDs light up and high precision mark color discrimination occurs using the R•G•B reflective light ratio. This function enables effective detection of films with patterns around the area of the mark. WIRE-SAVING SYSTEMS The color around letters is detected as a mark. MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS Predetermined colors are detected as marks. UV CURING SYSTEMS * You can select the mark mode or color mode through key operation. High precision mark color discrimination The color mode on the LX-100 series utilizes all 3 R•G•B LEDs to determine the R•G•B ratio of the mark color. The built-in 12-bit A/D converter enables high precision 1/4,000-resolution judgments. The figure below is a graphic description of this process. 1. 1-level teaching for this mark 2. R•G•B ratio calculated 3. Precise determination of consistency of the spot color (R•G•B ratio) a Inconsistent c Inconsistent b b R: 15 G: 10 B: 5 LX-100 FZ-10 Mark Even similar colors are accurately determined using the R•G•B ratio. Ultrasonic Small / Slim Object Detection Obstacle Detection c Reflective light a b Consistent Selection Guide Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Wafer Detection 13 : 10 : 5 15 : 10 : 5 15 : 10 : 6 901 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC Digital Mark Sensor LX-100 SERIES Its digital display makes settings easy! Numerical control of the settings is possible The 4-digit digital display enables easy verification of received light from marks and base (non-mark area). Also, the threshold value can be controlled numerically enabling setting indication easily. Displaying the direct code enables settings verification. This function is handy for remote maintenance. MODE indicator 4-digit digital display amount and ( Light-receiving setting values are displayed. ) MODE indicator Operation indicator MODE key (PRO mode: CANCEL key) OFF key (PRO mode: ENTER key) ON key (PRO mode: SELECT key) Even beginners can quickly master MODE NAVI operation The sensor’s basic operations are represented by 6 indicators (MODE NAVI). The user can check what mode the sensor is presently in with a quick glance making operation simple. This is the sensing mode. The digital display shows the light-receiving amount (mark mode) and the color consistency (color mode). This is the threshold value setting (teaching) mode. RUN COLOR This mode enables a mark mode/color mode selection. TEACH TIMER Timer type selection mode. ADJ PRO HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Wafer Detection This is the threshold fine-adjustment mode. Sensing status digitally controllable The sensing status, displayed numerically, can be verified at a glance. Also, the sensor settings for each type of packing film can be digitally indicated. LX-100 FZ-10 • Example of sensor setting indication ■ Selected LED: Red LED ■ Threshold value: 600 ■ Selected LED: Green LED ■ Threshold value: 1850 ■ Selected LED: Blue LED ■ Threshold value: 1600 Direct codes enable settings verification at a glance The settings for the LX-100 series sensors are displayed using a 4-digit direct code. Direct codes enable easy setting verification and maintenance by phone. Ultrasonic Small / Slim Object Detection Obstacle Detection This mode enables the setting of various functions such as key lock and timer period. What is the direct code? The direct code is 0004. At present, the sensor is operating with a mark at 2300 and base at 860. Digital Mark Sensor Direct code table (D-Code) ● When in RUN mode, press the MODE key for at least 2 sec. to display the direct code. (Remove your finger from the MODE key and the direct code will disappear.) The sensor setting modes can be verified by a 4-digit code (D-Code). The table below shows a list of all available codes. 1st digit 2nd digit Display Sensing mode (light source color) Operation mode (Note 1) Sensing (Note 2) FINE L-ON COARSE Mark mode (green) FINE D-ON COARSE FINE L-ON COARSE Mark mode (blue) FINE D-ON COARSE FINE L-ON COARSE Mark mode (red) FINE D-ON COARSE FINE Consistent-ON COARSE Color mode FINE Inconsistent-ON COARSE LX-100 SERIES 3rd digit Display Display mode ECO mode (Note 4) Turn mode (Note 5) Display Key lock OFF Full lock OFF ON Standard (All operations disabled) OFF ON ON RUN teaching OFF OFF (Teaching only enabled) ON Percent display OFF RUN adjust (Note 3) ON ON Threshold value adjustment only enabled ( ) 4th digit Timer mode Display Timer period 1 ms non 2 ms OFF-delay 5 ms ON-delay 10 ms non 20 ms OFF-delay 50 ms ON-delay 100 ms non 200 ms OFF-delay 500 ms ON-delay Press the ON button at the targeted mark. External teaching possible Here is an example of the most basic setting method “2-level teaching”. Teaching is possible through external input using an operation panel or touch panel even on hard-to-reach color mark sensors located inside an equipment. Also, models can be interchanged easily. Mode selection Press MODE key and select TEACH mode. Mark mode 2-level teaching and full-auto teaching possible 1 Align the spot on the mark and press the ON key. 2 Align the spot onto the base (non-mark area) and press the OFF key. * The 1 2 order can be reversed. Color mode 1-level teaching possible Display showing complete settings PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Other teaching methods • Full-auto teaching: In Mark mode, teaching is effective without stopping the sensing object. • 1-level teaching: In Color mode, the color detected is aligned by the spot and teaching is effective. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Ultrasonic Small / Slim Object Detection Obstacle Detection Compact design for significant space savings Key lock function High precision sensing and multiple functions are all packed in a compact W57 × D24 × H38 mm W2.244 × D0.945 × H1.496 in body. Cable and plug-in connector types are available depending on the equipment used. These sensors can mm be easily introduced 38 1.496 in to existing facilities. The key lock function enables input operation control that prevents mistaken changes in the sensor settings. Other detailed settings include “RUN adjust”, allowing threshold value adjustment only, and “RUN teaching”, allowing teaching operation only. If the sensor is set to “RUN adjust” or “RUN teaching”, adjustment and teaching are possible having the sensor remained in RUN mode. 57 mm 2.244 in SIMPLE WIRE-SAVING UNITS Selection Guide Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Wafer Detection Teaching complete. The optimal LED is automatically selected and the sensor automatically returns to RUN mode. 24 mm 0.945 in LASER SENSORS SENSOR OPTIONS Super simple teaching Sensing FIBER SENSORS PARTICULAR USE SENSORS Notes: 1) In Mark mode, L-ON/D-ON is automatically set in the sensor. For example, with 2-level teaching, press the ON key at the targeted mark and press the OFF key at the base (non-mark area). When doing so, the operator does not have to consider L-ON/D-ON. 2) Sensing accuracy can be set to either FINE (standard) or COARSE. 3) The percent display is only enabled in mark mode. 4) ECO mode is a function that reduces power consumption by turning off the digital display in the event that no button operations are made for a predetermined time (approx. 10 sec. or more) in RUN mode. Press any button to turn the digital display on again. 5) The turn mode is a function that reverses the digital display making it easily to be viewed in the event that the sensor installation renders the display up-side-down. * Default setting: D-code = “ ”. Teaching 902 LX-100 FZ-10 903 PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS ORDER GUIDE Sensors Mating cable is not supplied with the plug-in connector type. Please order it separately. Type Appearance Cable type LASER SENSORS Output LX-101 NPN open-collector transistor LX-101-P PNP open-collector transistor LX-101-Z NPN open-collector transistor LX-101-P-Z PNP open-collector transistor Type Model No. Description CN-24B-C2 Length: 2 m 6.562 ft CN-24B-C5 Length: 5 m 16.404 ft CN-24BL-C2 Length: 2 m 6.562 ft CN-24BL-C5 Length: 5 m 16.404 ft Straight 0.34 mm2 4-core cabtyre cable, with connector on one end Cable outer diameter: ø5 mm ø0.197 in Elbow Selection Guide Liquid Leak Detection Liquid Level Detection OPTIONS Type Sensor mounting bracket Model No. MS-LX-1 MS-LX-2 Description Mounting bracket made for LX-100 series applicable for various kinds of installations Sensor mounting bracket • MS-LX-1 • MS-LX-2 Water Detection Color Mark Detection Wafer Detection Ultrasonic Small / Slim Object Detection Obstacle Detection LX-100 FZ-10 ø14 mm ø0.551 in 43.5 mm 1.713 in ø5 mm ø0.197 in ø5 mm ø0.197 in ø14 mm ø0.551 in 29 mm 1.142 in FA COMPONENTS UV CURING SYSTEMS • CN-24BL-C2 • CN-24BL-C5 31 mm 1.220 in HUMAN MACHINE INTERFACES MACHINE VISION SYSTEMS Mating cables for plug-in connector type sensor • CN-24B-C2 • CN-24B-C5 PLC ENERGY MANAGEMENT SOLUTIONS Sensing range Mating cables for plug-in connector type sensor Mating cable is not supplied with the plug-in connector type sensor. Please order it separately. STATIC CONTROL DEVICES LASER MARKERS Model No. 10 ±3 mm 0.394 ±0.118 in WIRE-SAVING SYSTEMS MEASUREMENT SENSORS LX-100 SERIES Plug-in connector type FIBER SENSORS Digital Mark Sensor Two M4 (length 28 mm 1.102 in) screws with washers are attached. Two M4 (length 30 mm 1.181 in) screws with washers are attached. Digital Mark Sensor LX-100 SERIES SPECIFICATIONS Model No. Type Item FIBER SENSORS Cable type Plug-in connector type NPN output LX-101 LX-101-Z PNP output LX-101-P LX-101-P-Z CE marking directive compliance EMC Directive, RoHS Directive Sensing range Spot size 10 ±3 mm 0.394 ±0.118 in Output 1 (OUT) Output 2 (OUT) Short-circuit protection Output operation Response time Teaching input Digital display Sensitivity setting Normal mode: 750 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) PRESSURE / FLOW SENSORS NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (at 50 mA sink current) PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less (at 50 mA source current) Environmental resistance Ambient humidity Ambient illuminance Voltage withstandability Vibration resistance Shock resistance Emitting element Material Cable Cable extension Weight Accessory NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (at 100 mA sink current) PNP open-collector transistor • Maximum source current: 100 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less (at 100 mA source current) Incorporated Mark mode: Light-ON / Dark-ON (Auto-setting on teaching), Color mode: Consistent-ON / Inconsistent-ON (Setting on teaching) – Incorporated – Inverted operation of the output 1 – PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS Mark mode: 45 µs or less, Color mode: 150 µs or less NPN non-contact input • Signal condition: High… +5 V to +V, or open Low… 0 to +2 V (source current: 0.5 mA or less) • Input impedance: 10 kΩ approx. INDUCTIVE PROXIMITY SENSORS STATIC CONTROL DEVICES NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (at 50 mA sink current) PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less (at 50 mA source current) PNP non-contact input • Signal condition: High… +4 V to +V (sink current: 3 mA or less) Low… 0 to +0.6 V, or open • Input impedance: 10 kΩ approx. UV CURING SYSTEMS 4-digit red LED display Selection Guide Mark mode: 2-level teaching / Full-auto teaching, Color mode: 1-level teaching Liquid Leak Detection Incorporated Liquid Level Detection Incorporated with variable ON-delay/OFF-delay timer, switchable either effective or ineffective (Timer period: 1 to 500 ms, 9 levels variable) Water Detection Protection Ambient temperature MICRO PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Fine sensitivity adjustment function Timer function PHOTOELECTRIC SENSORS 12 to 24 V DC ±10 %   Ripple P-P 10 % or less Short-circuit protection Output operation LASER SENSORS AREA SENSORS 1 × 5 mm 0.039 × 0.197 in (at 10 mm 0.394 in setting distance) Supply voltage Current consumption 904 IP67 (IEC) –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F Incandescent light: 3,000 ℓx or less at the light-receiving face 1,000 V AC for one min. between all supply terminals connected together and enclosure 10 to 500 Hz frequency, 3.0 mm 0.118 in double amplitude (max. 20 G) in X, Y and Z directions for two hours each 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each Combined Red / Green / Blue LEDs (Peak emission wavelength: 640 nm 0.025 mil / 525 nm 0.021 mil / 470 nm 0.019 mil) Enclosure: PBT, Display cover: Polycarbonate, Operation buttons: Silicone rubber, Lens: Glass, Lens holder: Aluminum (Note 2) Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. Net weight: 120 g approx., Gross weight: 180 g approx. Wafer Detection Ultrasonic 35 to 85 % RH, Storage: 35 to 85 % RH 0.2 mm2 5-core cabtyre cable, 2 m 6.562 ft long Color Mark Detection Net weight: 55 g approx., Gross weight: 120 g approx. M4 (length 30 mm 1.181 in) screw with washers: 2 pcs. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) Mating cable is not supplied with the plug-in connector type. Please order it separately. Small / Slim Object Detection Obstacle Detection LX-100 FZ-10 905 Digital Mark Sensor I/O CIRCUIT AND WIRING DIAGRAMS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS LX-101(-Z) D1 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS PLC ZD2 ZD1 10 kΩ D2 +5 V Internal circuit Color code of cable type/ mating cable for plug-in connector type 2 Terminal No. of plug-in connector type (Brown) +V 10 kΩ D2 Load (Black) Output 1 Load (White) Output 2 (Note 2) 50 mA max. (Note 1) + 50 mA max. (Note 1) 3 – 12 to 24 V DC ±10 % (Pink) Teaching input (Blue) 0 V (Pink) Teaching input *1 50 mA max. (Note 1) 4 Tr2 D1 3 Internal circuit Users’ circuit 2 (Brown) +V ZD2 Tr1 *1 (Black) Output 1 50 mA max. (Note 1) (White) Output 2 (Note 2) Load +V Load (Blue) 0 V Users’ circuit or Non-voltage contact or PNP transistor • Teaching input High: 5 V to +V, or open Low: 0 to +2 V (source current: 0.5 mA or less) Teaching is carried out at the Low. or 0V Symbols … D1, D2 : Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : NPN output transistor • Teaching input High: +4 V to +V (sink current: 3 mA or less) Low: 0 to +0.6 V, or open Teaching is carried out at the High. Symbols … D1, D2 : Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : PNP output transistor Connector pin layout of plug-in connector type MACHINE VISION SYSTEMS Connector pin No. Description 1 +V 2 Teaching input 3 0V 4 Output SPOT SIZE CHARACTERISTICS (TYPICAL) (Unit: mm in) Spot size (Note 2) Setting distance L (Note 1) Width (W) Length (D) 7 0.276 2.0 0.079 5.5 0.217 8 0.315 1.7 0.067 5.5 0.217 Color Mark Detection 9 0.354 1.2 0.047 5.3 0.209 Wafer Detection 10 0.394 1.0 0.039 5.0 0.197 Selection Guide Liquid Leak Detection Liquid Level Detection W Water Detection L D 11 0.433 1.3 0.051 5.0 0.197 Small / Slim Object Detection 12 0.472 1.5 0.059 5.0 0.197 Obstacle Detection 13 0.512 2.0 0.079 5.0 0.197 FZ-10 12 to 24 V DC ±10 % * 1 Non-voltage contact or NPN transistor FA COMPONENTS LX-100 – * 1 ENERGY MANAGEMENT SOLUTIONS Ultrasonic + Notes: 1) The current of the plug-in connector type LX-101-P-Z is 100 mA max. 2) The output 2 is not incorporated to the plug-in connector type LX-101-P-Z. HUMAN MACHINE INTERFACES UV CURING SYSTEMS ZD1 0V 1 Color code of cable type/ mating cable for plug-in connector type Notes: 1) The current of the plug-in connector type LX-101-Z is 100 mA max. 2) The output 2 is not incorporated to the plug-in connector type LX-101-Z. MEASUREMENT SENSORS LASER MARKERS 4 Tr2 WIRE-SAVING SYSTEMS STATIC CONTROL DEVICES 1 Tr1 PNP output type I/O circuit diagram Terminal No. of plug-in connector type INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS LX-101-P(-Z) NPN output type I/O circuit diagram Sensor circuit PHOTOELECTRIC SENSORS Sensor circuit FIBER SENSORS LASER SENSORS LX-100 SERIES Notes: 1) S  etting distance “L” represents the distance from the lens surface to the sensing object. 2) Examples only meant for use as a guideline. Digital Mark Sensor PRECAUTIONS FOR PROPER USE • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Mounting • Care must be taken regarding the sensor mounting direction with respect to the object’s direction of movement. Do not make the sensor detect an object in this direction because it may cause unstable operation. Mark and base Mark and base • With the optional sensor mounting bracket, the tightening torque should be 0.8 N·m or less. Sensing glossy object • Objects with a glossy surface have a large amount of specular reflection particles that may destabilize sensing. In such a case, by slightly tilting the sensor’s beam axis, this specular reflection can be reduced rendering sensing more stable. • If the surface of the sensing object has a shine, mount the sensor inclining approx. 10 to 15 degrees against the sensing object. 10 to 15° Wiring • Make sure to carry out wiring in the power supply off condition. • Take care that wrong wiring will damage the sensor. • Verify that the supply voltage variation is within the rating. • Take care that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the sensor may get burnt or damaged. • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. • Take care that short-circuit of the load or wrong wiring may burn or damage the sensor. • Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. • Extension up to total 100 m is possible with 0.3 mm2, or more, cable. However, in order to reduce noise, make the wiring as short as possible. LX-100 SERIES 906 Refer to p.1552~ for general precautions. Others • Do not use during the initial transient time (0.5 sec.) after the power supply is switched on. • Take care that the sensor is not directly exposed to fluorescent light from a rapid-starter lamp or a high frequency light device or sunlight etc., as it may affect the sensing performance. • Do not touch the lens of the sensor by hand directly. If the lens becomes dirty, wipe it off with a soft cloth gently. • When the inside lens is steamed up, unscrew the lens to get rid of the condensation. • These sensors are only for indoor use. • Do not use this sensor in places having excessive vapor, dust, etc., or where it may come in direct contact with water, or corrosive gas. • Take care that the product does not come in contact with water, oil, grease, or organic solvents, such as, thinner, etc. • Make sure that stress by forcible bend or pulling with 76 N, or more, force is not applied to the sensor cable joint. • This sensor cannot be used in an environment containing inflammable or explosive gases. • Never disassemble or modify the sensor. FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Wafer Detection Ultrasonic Small / Slim Object Detection Obstacle Detection LX-100 FZ-10 907 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Digital Mark Sensor LIST OF PROMODE SETTING ITEMS • Before performing teaching or each detail setting, perform the setting of either mark mode or color mode with mark/color mode setting of NAVI mode. Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Wafer Detection Ultrasonic Small / Slim Object Detection Obstacle Detection LX-100 FZ-10 PROmode • For selecting a setting item, press 'ON key'. For confirming each selected setting item, press 'OFF / ENTER key'. After confirming setting, the digital display flashes. For canceling setting, press 'MODE key'. NAVI mode RUN Run OFF At mark mode setting: Indicates the absolute value of emitting amount. It is possible to indicate the relative value (percent value) against threshold value. At color mode setting: Indicates color matching degree with relative value. Press Sensing setting Sets the sensing level (hysteresis.) TEACH SELECT Sensing level: Fine (20 ms) Teaching Adjust At mark mode setting: Allows fine adjustment of the threshold value. At color mode setting: Allows adjustment of sensing tolerance value. Sensing level: Coarse (50 ms) (100 ms) (200 ms) (500 ms) (10 ms) (5 ms) (2 ms) (1 ms) Sets timer setting period by 9-steps. At mark mode setting: Sets the threshold value by '2-level teaching' or 'full-auto teaching'. At color mode setting: Sets the threshold value by '1-level teaching'. ADJ. OFF Press ENTER Timer setting Press Key lock setting Set full key lock. Selects key lock function. Set key lock except for RUN adjust mode.(RUN adjust) OFF Press ENTER Set key lock except for RUN teaching mode. (RUN teaching) Display setting Selects display method of digital desplay. Mark mode setting: Displays incident light intesity Color mode setting: Displays color coincidence Mark mode setting: Displays relative value (percentage) Color mode setting: Displays color coincidence Eco setting COLOR Sets ON/OFF of eco mode. Mark/Color mode setting Sets mark mode or color mode. TIMER Changes display direction of digital display. Eco setting: ON Not invert the display. Invert the display. Reset setting PRO Allows various detailed settings to be configured. Eco setting: OFF Display inverting mode setting Timer operation setting Configures operation of the timer. PRO Selection Guide LX-100 SERIES Resets to factory setting. Press Press Not reset the settings. Reset the settings. Digital Mark Sensor DIMENSIONS (Unit: mm in) 24 0.945 1.5 0.059 OPE. Sensor LX-101-Z  LX-101-P-Z COLOR TIMER PRO MODE ON CANCEL SELECT TEACH 24 0.945 OFF RUN TEACH ADJ OPE. ENTER 57 2.244 47 1.850 5 0.197 Sensor MODE ON CANCEL SELECT TEACH ENTER AREA SENSORS 57 2.244 47 1.850 5 0.197 35 25 1.378 0.984 ø14.4 ø0.567 M12 ( MS-LX-1 5 0.197 3 0.118 2-ø4.5 ø0.177 mounting holes ) Sensor mounting bracket (Optional) 4-R2 R0.079 39 1.535 27 1.063 15 0.591 28 1.102 ( ø22 ø0.866 15 0.591 30.4 1.197 21 0.827 R2 R0.079 2-R5 R0.197 5 0.197 25 0.984 80 3.150 R2 R0.079 4 0.157 6 0.236 9 0.354 47 1.850 57 2.244 72 2.835 Material: Stainless steel (SUS) Two M4 (length 28 mm 1.102 in) screws with washers are attached. 28 1.102 41 1.614 3 0.118 3-M5 × 0.8 0.031 27.2 1.071 SENSOR OPTIONS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS 60 2.362 LASER MARKERS PLC R4.7 R0.185 45 40 1.772 30 1.575 1.181 15 0.591 PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS 2-M5 × 0.8 0.031 25 0.984 PRESSURE / FLOW SENSORS STATIC CONTROL DEVICES 2-R5 R0.197 5 0.197 2-ø4.5 ø0.177 mounting holes Sensor mounting bracket (Optional) 20 0.787 2-R4.7 R0.185 57 47 2.244 1.850 ) MS-LX-2 3 0.118 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS INDUCTIVE PROXIMITY SENSORS 35 25 1.378 0.984 ø22 ø0.866 15 0.591 LASER SENSORS MICRO PHOTOELECTRIC SENSORS OFF 71.5 2.815 1.5 0.059 FIBER SENSORS PHOTOELECTRIC SENSORS COLOR TIMER PRO 9.4 0.370 5 0.197 3 0.118 908 The CAD data can be downloaded from our website. LX-101  LX-101-P RUN TEACH ADJ LX-100 SERIES 15 0.591 3-R2 R0.079 HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS 2-M4 × 0.7 0.028 57.2 2.252 2-R5 10 R0.197 0.394 47 57 1.850 2.244 4 0.157 MACHINE VISION SYSTEMS UV CURING SYSTEMS R2 R0.079 4-M4 × 0.7 0.028 6 0.236 25 0.984 5 5 0.197 0.197 Material: Stainless steel (SUS) Two M4 (length 30 mm 1.181 in) screws with washers are attached. Selection Guide Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Wafer Detection Ultrasonic Small / Slim Object Detection Obstacle Detection LX-100 FZ-10
LX-101-P-Z 价格&库存

很抱歉,暂时无法提供与“LX-101-P-Z”相匹配的价格&库存,您可以联系我们找货

免费人工找货
LX-101-P-Z
  •  国内价格
  • 1+4405.85494

库存:4