899
FIBER
SENSORS
Digital Mark Sensor
Amplifier Built-in
LX-100 SERIES
Related Information
■■General terms and conditions.............. F-3
■■Glossary of terms........................ P.1549~
■■Selection guide...............................P.865~
■■General precautions.................... P.1552~
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Recognition
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
panasonic.net/id/pidsx/global
STATIC
CONTROL
DEVICES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Liquid Leak
Detection
Liquid Level
Detection
Water
Detection
Color Mark
Detection
Wafer
Detection
Ultrasonic
Small / Slim
Object Detection
Obstacle
Detection
LX-100
FZ-10
Automatic
sensitivity setting
Can detect any mark!
Coaxial reflective optics and a sharp 1 × 5 mm 0.039
× 0.197 in spot enable high precision sensing. Stable
detection of marks is possible.
Newly
developed
4-digit digital display
The 4-digit digital display enables
numerical sensing control and
minute settings.
Operation panel
R•G•B light emitting
elements all in one
3 large buttons that click into position
making operation easy.
To detect any marking, this unit is
blue
equipped with red, green and blue
light emitting
emittingelements
elementsallallinin
LED light
one.
Highest in
the industry
12-bit A/D converter
A resolution of 1/4,000 is realized to
enable high precision mark sensing.
Total reflection
High precision coaxial
mirror
reflective optical system
Panasonic
Industrial
Devicesreflective
SUNX’s
SUNX’s unique
coaxial
optics coaxial
technology
ensures
unique
reflective
optics very
accurate sensing.
is made
technology
ensuresThe
veryunit
accurate
with a scratchproof
glass with
lens.a
sensing.
The unit is made
scratchproof glass lens.
Half mirror
Receiving element
Glass lens
Protection IP67
Washing the machines and
production line with water will
not affect the sensor thanks
to its waterproof construction.
Spot size 1 × 5 mm
0.039 × 0.197 in approx.
▲Image schematic
Automatic optimal LED selection function
The 3 colors of the R•G•B LEDs are
optimally selected according to the color
combination. With the LX-100’s Mark mode,
the built-in “Automatic optimal LED selection
function” automatically selects the LED for
the largest contrast (S/N ratio) between the
mark and base (non-mark area) to ensure
optimal sensing. For more stable detection,
the sensor makes selection according to the
contrast and not according to the reflected
light variation between the mark and base
(non-mark area).
The example on the right deals with reflected light
on packing film.
Great figures are indicated for the blue LED’s light
amount ratio and, for even more stable sensing,
the blue LED effectuates this mark sensing.
Example: A packing film
Mark
Light amount
=
ratio
Base
6 : 8
Reflective light
HUMAN MACHINE
INTERFACES
Timer
Introduction of the 3 LED mark sensor
Reflective light
PLC
Reflective light
LASER
MARKERS
PNP output
type available
Mark
Light amount
=
ratio
Base
8 : 4
Optimal
Mark
Light amount
=
ratio
Base
4 : 1
Digital Mark Sensor
LX-100 SERIES
Two detection modes can be selected from to suit the application
Mark mode Ultra high-speed response
This sensing mode automatically selects
a single color from the 3 R•G•B LEDs to
achieve an ultra quick 45 µs response
time. The automatic optimal LED
selection function automatically selects
the LED that is most suitable for the
sensing. This function is perfect for ultra
quick sensing.
RED
900
FIBER
SENSORS
Automatic selection of the optimal LED
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
GREEN
BLUE
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
Color mode High precision discrimination
SIMPLE
WIRE-SAVING
UNITS
All 3 R•G•B LEDs light up and high
precision mark color discrimination
occurs using the R•G•B reflective light
ratio. This function enables effective
detection of films with patterns around
the area of the mark.
WIRE-SAVING
SYSTEMS
The color around letters is
detected as a mark.
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
Predetermined colors are
detected as marks.
UV CURING
SYSTEMS
* You can select the mark mode or color mode through key operation.
High precision mark color discrimination
The color mode on the LX-100 series utilizes all 3 R•G•B LEDs to determine the R•G•B ratio of the mark color.
The built-in 12-bit A/D converter enables high precision 1/4,000-resolution judgments. The figure below is a graphic
description of this process.
1. 1-level teaching for this mark
2. R•G•B ratio calculated 3. Precise determination of consistency of the spot color (R•G•B ratio)
a Inconsistent
c Inconsistent
b
b
R: 15
G: 10
B: 5
LX-100
FZ-10
Mark
Even similar colors are accurately determined using the R•G•B ratio.
Ultrasonic
Small / Slim
Object Detection
Obstacle
Detection
c
Reflective light
a
b Consistent
Selection
Guide
Liquid Leak
Detection
Liquid Level
Detection
Water
Detection
Color Mark
Detection
Wafer
Detection
13 : 10 : 5
15 : 10 : 5
15 : 10 : 6
901
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
Digital Mark Sensor
LX-100 SERIES
Its digital display makes settings easy! Numerical control of the settings is possible
The 4-digit digital display enables easy verification of received light from marks and base (non-mark area). Also, the
threshold value can be controlled numerically enabling setting indication easily. Displaying the direct code enables
settings verification. This function is handy for remote maintenance.
MODE indicator
4-digit digital display
amount and
( Light-receiving
setting values are displayed. )
MODE indicator
Operation indicator
MODE key
(PRO mode: CANCEL key)
OFF key
(PRO mode: ENTER key)
ON key
(PRO mode: SELECT key)
Even beginners can quickly master MODE NAVI operation
The sensor’s basic operations are represented by 6 indicators (MODE NAVI). The user can check what mode the
sensor is presently in with a quick glance making operation simple.
This is the sensing mode. The digital display
shows the light-receiving amount (mark mode)
and the color consistency (color mode).
This is the threshold value
setting (teaching) mode.
RUN
COLOR
This mode enables a mark
mode/color mode selection.
TEACH
TIMER
Timer type selection mode.
ADJ
PRO
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Liquid Leak
Detection
Liquid Level
Detection
Water
Detection
Color Mark
Detection
Wafer
Detection
This is the threshold
fine-adjustment mode.
Sensing status digitally controllable
The sensing status, displayed
numerically, can be verified at a
glance. Also, the sensor settings
for each type of packing film can be
digitally indicated.
LX-100
FZ-10
• Example of sensor setting indication
■ Selected LED: Red LED
■ Threshold value: 600
■ Selected LED: Green LED
■ Threshold value: 1850
■ Selected LED: Blue LED
■ Threshold value: 1600
Direct codes enable settings verification at a glance
The settings for the LX-100 series sensors are displayed using a 4-digit direct code. Direct codes enable easy setting
verification and maintenance by phone.
Ultrasonic
Small / Slim
Object Detection
Obstacle
Detection
This mode enables the setting
of various functions such as
key lock and timer period.
What is the
direct code?
The direct code is 0004. At present,
the sensor is operating with a mark
at 2300 and base at 860.
Digital Mark Sensor
Direct code table (D-Code)
● When in RUN mode, press the MODE
key for at least 2 sec. to display the
direct code. (Remove your finger from
the MODE key and the direct code will
disappear.)
The sensor setting modes can be verified by a 4-digit
code (D-Code). The table below shows a list of all
available codes.
1st digit
2nd digit
Display Sensing mode (light source color) Operation mode (Note 1) Sensing (Note 2)
FINE
L-ON
COARSE
Mark mode (green)
FINE
D-ON
COARSE
FINE
L-ON
COARSE
Mark mode (blue)
FINE
D-ON
COARSE
FINE
L-ON
COARSE
Mark mode (red)
FINE
D-ON
COARSE
FINE
Consistent-ON
COARSE
Color mode
FINE
Inconsistent-ON
COARSE
LX-100 SERIES
3rd digit
Display Display mode ECO mode (Note 4) Turn mode (Note 5) Display
Key lock
OFF
Full lock
OFF
ON
Standard
(All operations disabled)
OFF
ON
ON
RUN teaching
OFF
OFF
(Teaching only enabled)
ON
Percent display
OFF
RUN adjust
(Note 3)
ON
ON
Threshold value
adjustment only enabled
(
)
4th digit
Timer mode Display Timer period
1 ms
non
2 ms
OFF-delay
5 ms
ON-delay
10 ms
non
20 ms
OFF-delay
50 ms
ON-delay
100 ms
non
200 ms
OFF-delay
500 ms
ON-delay
Press the ON button at the targeted mark.
External teaching possible
Here is an example of the most basic setting method
“2-level teaching”.
Teaching is possible through external input using an
operation panel or touch panel even on hard-to-reach
color mark sensors located inside an equipment. Also,
models can be interchanged easily.
Mode selection Press MODE key and select TEACH mode.
Mark mode
2-level teaching and full-auto teaching possible
1 Align the spot on the mark and press the ON key.
2 Align the spot onto the base (non-mark area) and press the OFF key.
* The 1 2 order can be reversed.
Color mode
1-level teaching possible
Display showing
complete settings
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Other teaching methods
• Full-auto teaching: In Mark mode, teaching is effective
without stopping the sensing object.
• 1-level teaching: In Color mode, the color detected is aligned
by the spot and teaching is effective.
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Ultrasonic
Small / Slim
Object Detection
Obstacle
Detection
Compact design for significant space savings
Key lock function
High precision sensing and multiple functions are all
packed in a compact W57 × D24 × H38 mm W2.244
× D0.945 × H1.496 in body.
Cable and plug-in connector
types are available
depending on the
equipment used.
These sensors can
mm
be easily introduced 38
1.496 in
to existing facilities.
The key lock function enables input operation control
that prevents mistaken changes in the sensor settings.
Other detailed settings include “RUN adjust”, allowing
threshold value adjustment only, and “RUN teaching”,
allowing teaching operation only.
If the sensor is set to “RUN adjust” or “RUN teaching”,
adjustment and teaching are possible having the sensor
remained in RUN mode.
57 mm
2.244 in
SIMPLE
WIRE-SAVING
UNITS
Selection
Guide
Liquid Leak
Detection
Liquid Level
Detection
Water
Detection
Color Mark
Detection
Wafer
Detection
Teaching complete. The optimal LED is
automatically selected and the sensor
automatically returns to RUN mode.
24 mm
0.945 in
LASER
SENSORS
SENSOR
OPTIONS
Super simple teaching
Sensing
FIBER
SENSORS
PARTICULAR
USE SENSORS
Notes: 1) In Mark mode, L-ON/D-ON is automatically set in the sensor. For example, with 2-level teaching, press the ON key at the targeted mark and
press the OFF key at the base (non-mark area). When doing so, the operator does not have to consider L-ON/D-ON.
2) Sensing accuracy can be set to either FINE (standard) or COARSE.
3) The percent display is only enabled in mark mode.
4) ECO mode is a function that reduces power consumption by turning off the digital display in the event that no button operations are made for
a predetermined time (approx. 10 sec. or more) in RUN mode. Press any button to turn the digital display on again.
5) The turn mode is a function that reverses the digital display making it easily to be viewed in the event that the sensor installation renders the display up-side-down.
* Default setting: D-code = “
”.
Teaching
902
LX-100
FZ-10
903
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
ORDER GUIDE
Sensors Mating cable is not supplied with the plug-in connector type. Please order it separately.
Type
Appearance
Cable type
LASER
SENSORS
Output
LX-101
NPN open-collector transistor
LX-101-P
PNP open-collector transistor
LX-101-Z
NPN open-collector transistor
LX-101-P-Z
PNP open-collector transistor
Type
Model No.
Description
CN-24B-C2
Length: 2 m 6.562 ft
CN-24B-C5
Length: 5 m 16.404 ft
CN-24BL-C2
Length: 2 m 6.562 ft
CN-24BL-C5
Length: 5 m 16.404 ft
Straight
0.34 mm2 4-core cabtyre cable, with
connector on one end
Cable outer diameter: ø5 mm ø0.197 in
Elbow
Selection
Guide
Liquid Leak
Detection
Liquid Level
Detection
OPTIONS
Type
Sensor
mounting
bracket
Model No.
MS-LX-1
MS-LX-2
Description
Mounting bracket made for LX-100 series applicable for
various kinds of installations
Sensor mounting bracket
• MS-LX-1
• MS-LX-2
Water
Detection
Color Mark
Detection
Wafer
Detection
Ultrasonic
Small / Slim
Object Detection
Obstacle
Detection
LX-100
FZ-10
ø14 mm
ø0.551 in
43.5 mm
1.713 in
ø5 mm
ø0.197 in
ø5 mm
ø0.197 in
ø14 mm
ø0.551 in
29 mm
1.142 in
FA
COMPONENTS
UV
CURING
SYSTEMS
• CN-24BL-C2
• CN-24BL-C5
31 mm
1.220 in
HUMAN
MACHINE
INTERFACES
MACHINE
VISION
SYSTEMS
Mating cables for plug-in connector
type sensor
• CN-24B-C2
• CN-24B-C5
PLC
ENERGY
MANAGEMENT
SOLUTIONS
Sensing range
Mating cables for plug-in connector type sensor Mating cable is not supplied with the plug-in connector type sensor. Please order it separately.
STATIC
CONTROL
DEVICES
LASER
MARKERS
Model No.
10 ±3 mm 0.394 ±0.118 in
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
LX-100 SERIES
Plug-in
connector
type
FIBER
SENSORS
Digital Mark Sensor
Two M4 (length 28 mm 1.102 in) screws with
washers are attached.
Two M4 (length 30 mm 1.181 in) screws with
washers are attached.
Digital Mark Sensor
LX-100 SERIES
SPECIFICATIONS
Model No.
Type
Item
FIBER
SENSORS
Cable type
Plug-in connector type
NPN output
LX-101
LX-101-Z
PNP output
LX-101-P
LX-101-P-Z
CE marking directive compliance
EMC Directive, RoHS Directive
Sensing range
Spot size
10 ±3 mm 0.394 ±0.118 in
Output 1
(OUT)
Output 2
(OUT)
Short-circuit protection
Output operation
Response time
Teaching input
Digital display
Sensitivity setting
Normal mode: 750 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
PRESSURE /
FLOW
SENSORS
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less (at 50 mA sink current)
PNP open-collector transistor
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less (at 50 mA source current)
Environmental resistance
Ambient humidity
Ambient illuminance
Voltage withstandability
Vibration resistance
Shock resistance
Emitting element
Material
Cable
Cable extension
Weight
Accessory
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less (at 100 mA sink current)
PNP open-collector transistor
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less (at 100 mA source current)
Incorporated
Mark mode: Light-ON / Dark-ON (Auto-setting on teaching), Color mode: Consistent-ON / Inconsistent-ON (Setting on teaching)
–
Incorporated
–
Inverted operation of the output 1
–
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
Mark mode: 45 µs or less, Color mode: 150 µs or less
NPN non-contact input
• Signal condition: High… +5 V to +V, or open
Low… 0 to +2 V
(source current: 0.5 mA or less)
• Input impedance: 10 kΩ approx.
INDUCTIVE
PROXIMITY
SENSORS
STATIC
CONTROL
DEVICES
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less (at 50 mA sink current)
PNP open-collector transistor
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less (at 50 mA source current)
PNP non-contact input
• Signal condition: High… +4 V to +V
(sink current: 3 mA or less)
Low… 0 to +0.6 V, or open
• Input impedance: 10 kΩ approx.
UV
CURING
SYSTEMS
4-digit red LED display
Selection
Guide
Mark mode: 2-level teaching / Full-auto teaching, Color mode: 1-level teaching
Liquid Leak
Detection
Incorporated
Liquid Level
Detection
Incorporated with variable ON-delay/OFF-delay timer, switchable either effective or ineffective (Timer period: 1 to 500 ms, 9 levels variable)
Water
Detection
Protection
Ambient temperature
MICRO
PHOTOELECTRIC
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
Fine sensitivity adjustment function
Timer function
PHOTOELECTRIC
SENSORS
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Short-circuit protection
Output operation
LASER
SENSORS
AREA
SENSORS
1 × 5 mm 0.039 × 0.197 in (at 10 mm 0.394 in setting distance)
Supply voltage
Current consumption
904
IP67 (IEC)
–10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F
Incandescent light: 3,000 ℓx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3.0 mm 0.118 in double amplitude (max. 20 G) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Combined Red / Green / Blue LEDs (Peak emission wavelength: 640 nm 0.025 mil / 525 nm 0.021 mil / 470 nm 0.019 mil)
Enclosure: PBT, Display cover: Polycarbonate, Operation buttons: Silicone rubber, Lens: Glass, Lens holder: Aluminum
(Note 2)
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight: 120 g approx., Gross weight: 180 g approx.
Wafer
Detection
Ultrasonic
35 to 85 % RH, Storage: 35 to 85 % RH
0.2 mm2 5-core cabtyre cable, 2 m 6.562 ft long
Color Mark
Detection
Net weight: 55 g approx., Gross weight: 120 g approx.
M4 (length 30 mm 1.181 in) screw with washers: 2 pcs.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) Mating cable is not supplied with the plug-in connector type. Please order it separately.
Small / Slim
Object Detection
Obstacle
Detection
LX-100
FZ-10
905
Digital Mark Sensor
I/O CIRCUIT AND WIRING DIAGRAMS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
LX-101(-Z)
D1
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
PLC
ZD2
ZD1
10 kΩ D2
+5 V
Internal circuit
Color code of cable type/
mating cable for plug-in connector type
2
Terminal No. of plug-in connector type
(Brown) +V
10 kΩ D2
Load
(Black) Output 1
Load
(White) Output 2 (Note 2) 50 mA max. (Note 1) +
50 mA max. (Note 1)
3
–
12 to 24 V DC
±10 %
(Pink) Teaching input
(Blue) 0 V
(Pink) Teaching input
*1
50 mA max. (Note 1)
4
Tr2
D1
3
Internal circuit
Users’ circuit
2
(Brown) +V
ZD2
Tr1
*1
(Black) Output 1 50 mA max. (Note 1)
(White) Output 2 (Note 2) Load
+V
Load
(Blue) 0 V
Users’ circuit
or
Non-voltage contact or PNP transistor
• Teaching input
High: 5 V to +V, or open
Low: 0 to +2 V (source current: 0.5 mA or less)
Teaching is carried out at the Low.
or
0V
Symbols … D1, D2 : Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1, Tr2 : NPN output transistor
• Teaching input
High: +4 V to +V (sink current: 3 mA or less)
Low: 0 to +0.6 V, or open
Teaching is carried out at the High.
Symbols … D1, D2 : Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1, Tr2 : PNP output transistor
Connector pin layout of plug-in connector type
MACHINE
VISION
SYSTEMS
Connector pin No.
Description
1
+V
2
Teaching input
3
0V
4
Output
SPOT SIZE CHARACTERISTICS (TYPICAL)
(Unit: mm in)
Spot size (Note 2)
Setting distance L
(Note 1)
Width (W)
Length (D)
7 0.276
2.0 0.079
5.5 0.217
8 0.315
1.7 0.067
5.5 0.217
Color Mark
Detection
9 0.354
1.2 0.047
5.3 0.209
Wafer
Detection
10 0.394
1.0 0.039
5.0 0.197
Selection
Guide
Liquid Leak
Detection
Liquid Level
Detection
W
Water
Detection
L
D
11 0.433
1.3 0.051
5.0 0.197
Small / Slim
Object Detection
12 0.472
1.5 0.059
5.0 0.197
Obstacle
Detection
13 0.512
2.0 0.079
5.0 0.197
FZ-10
12 to 24 V DC
±10 %
* 1
Non-voltage contact or NPN transistor
FA
COMPONENTS
LX-100
–
* 1
ENERGY
MANAGEMENT
SOLUTIONS
Ultrasonic
+
Notes: 1) The current of the plug-in connector type LX-101-P-Z is 100 mA max.
2) The output 2 is not incorporated to the plug-in connector type LX-101-P-Z.
HUMAN
MACHINE
INTERFACES
UV
CURING
SYSTEMS
ZD1
0V
1
Color code of cable type/
mating cable for plug-in connector type
Notes: 1) The current of the plug-in connector type LX-101-Z is 100 mA max.
2) The output 2 is not incorporated to the plug-in connector type LX-101-Z.
MEASUREMENT
SENSORS
LASER
MARKERS
4
Tr2
WIRE-SAVING
SYSTEMS
STATIC
CONTROL
DEVICES
1
Tr1
PNP output type
I/O circuit diagram
Terminal No. of plug-in connector type
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
LX-101-P(-Z)
NPN output type
I/O circuit diagram
Sensor circuit
PHOTOELECTRIC
SENSORS
Sensor circuit
FIBER
SENSORS
LASER
SENSORS
LX-100 SERIES
Notes: 1) S
etting distance “L” represents the distance from
the lens surface to the sensing object.
2) Examples only meant for use as a guideline.
Digital Mark Sensor
PRECAUTIONS FOR PROPER USE
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
Mounting
• Care must be taken regarding the sensor mounting
direction with respect to the object’s direction of movement.
Do not make the
sensor detect an object
in this direction
because it may cause
unstable operation.
Mark and base
Mark and base
• With the optional sensor mounting bracket, the
tightening torque should be 0.8 N·m or less.
Sensing glossy object
• Objects with a glossy surface have a large amount of
specular reflection particles that may destabilize sensing.
In such a case, by slightly tilting the sensor’s beam axis,
this specular reflection can be reduced rendering sensing
more stable.
• If the surface of the sensing object
has a shine, mount the sensor
inclining approx. 10 to 15 degrees
against the sensing object.
10 to 15°
Wiring
• Make sure to carry out wiring in the power supply off
condition.
• Take care that wrong wiring will damage the sensor.
• Verify that the supply voltage variation is within the rating.
• Take care that if a voltage exceeding the rated range is
applied, or if an AC power supply is directly connected,
the sensor may get burnt or damaged.
• In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this
product, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
• If power is supplied from a commercial switching
regulator, ensure that the frame ground (F.G.) terminal of
the power supply is connected to an actual ground.
• Take care that short-circuit of the load or wrong wiring
may burn or damage the sensor.
• Do not run the wires together with high-voltage lines or
power lines or put them in the same raceway. This can
cause malfunction due to induction.
• Extension up to total 100 m is possible with 0.3 mm2, or
more, cable. However, in order to reduce noise, make the
wiring as short as possible.
LX-100 SERIES
906
Refer to p.1552~ for general precautions.
Others
• Do not use during the initial transient time (0.5 sec.) after
the power supply is switched on.
• Take care that the sensor is not directly exposed to
fluorescent light from a rapid-starter lamp or a high
frequency light device or sunlight etc., as it may affect the
sensing performance.
• Do not touch the lens of the sensor by hand directly. If
the lens becomes dirty, wipe it off with a soft cloth gently.
• When the inside lens is steamed up, unscrew the lens to
get rid of the condensation.
• These sensors are only for indoor use.
• Do not use this sensor in places having excessive vapor,
dust, etc., or where it may come in direct contact with
water, or corrosive gas.
• Take care that the product does not come in contact with
water, oil, grease, or organic solvents, such as, thinner,
etc.
• Make sure that stress by forcible bend or pulling with
76 N, or more, force is not applied to the sensor cable
joint.
• This sensor cannot be used in an environment containing
inflammable or explosive gases.
• Never disassemble or modify the sensor.
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Liquid Leak
Detection
Liquid Level
Detection
Water
Detection
Color Mark
Detection
Wafer
Detection
Ultrasonic
Small / Slim
Object Detection
Obstacle
Detection
LX-100
FZ-10
907
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Digital Mark Sensor
LIST OF PROMODE SETTING ITEMS
• Before performing teaching or each detail setting, perform the setting of
either mark mode or color mode with mark/color mode setting of NAVI
mode.
Liquid Leak
Detection
Liquid Level
Detection
Water
Detection
Color Mark
Detection
Wafer
Detection
Ultrasonic
Small / Slim
Object Detection
Obstacle
Detection
LX-100
FZ-10
PROmode • For selecting a setting item, press 'ON key'. For confirming each selected setting item,
press 'OFF / ENTER key'. After confirming setting, the digital display flashes.
For canceling setting, press 'MODE key'.
NAVI mode
RUN
Run
OFF
At mark mode setting:
Indicates the absolute value
of emitting amount. It is
possible to indicate the
relative value (percent value)
against threshold value.
At color mode setting:
Indicates color matching
degree with relative value.
Press
Sensing setting
Sets the sensing level
(hysteresis.)
TEACH
SELECT
Sensing level: Fine
(20 ms)
Teaching
Adjust
At mark mode setting:
Allows fine adjustment of
the threshold value.
At color mode setting:
Allows adjustment of sensing
tolerance value.
Sensing level: Coarse
(50 ms)
(100 ms)
(200 ms)
(500 ms)
(10 ms)
(5 ms)
(2 ms)
(1 ms)
Sets timer setting period by
9-steps.
At mark mode setting:
Sets the threshold value by
'2-level teaching' or 'full-auto
teaching'.
At color mode setting:
Sets the threshold value by
'1-level teaching'.
ADJ.
OFF
Press
ENTER
Timer setting
Press
Key lock setting
Set full key lock.
Selects key lock function.
Set key lock except
for RUN adjust
mode.(RUN adjust)
OFF
Press
ENTER
Set key lock except
for RUN teaching mode.
(RUN teaching)
Display setting
Selects display method of
digital desplay.
Mark mode setting: Displays incident light intesity
Color mode setting: Displays color coincidence
Mark mode setting: Displays relative value (percentage)
Color mode setting: Displays color coincidence
Eco setting
COLOR
Sets ON/OFF of eco mode.
Mark/Color mode setting
Sets mark mode or color
mode.
TIMER
Changes display direction of
digital display.
Eco setting: ON
Not invert the display.
Invert the display.
Reset setting
PRO
Allows various detailed
settings to be configured.
Eco setting: OFF
Display inverting mode setting
Timer operation setting
Configures operation of the
timer.
PRO
Selection
Guide
LX-100 SERIES
Resets to factory setting.
Press
Press
Not reset the settings.
Reset the settings.
Digital Mark Sensor
DIMENSIONS (Unit: mm in)
24
0.945
1.5
0.059
OPE.
Sensor
LX-101-Z LX-101-P-Z
COLOR
TIMER
PRO
MODE
ON
CANCEL
SELECT
TEACH
24
0.945
OFF
RUN
TEACH
ADJ
OPE.
ENTER
57
2.244
47
1.850
5
0.197
Sensor
MODE
ON
CANCEL
SELECT
TEACH
ENTER
AREA
SENSORS
57
2.244
47
1.850
5
0.197
35 25
1.378 0.984
ø14.4
ø0.567
M12
(
MS-LX-1
5
0.197 3
0.118
2-ø4.5 ø0.177
mounting holes
)
Sensor mounting bracket (Optional)
4-R2 R0.079
39
1.535
27
1.063
15
0.591
28
1.102
(
ø22
ø0.866
15
0.591
30.4
1.197 21
0.827
R2
R0.079
2-R5 R0.197
5
0.197
25
0.984
80
3.150
R2 R0.079
4
0.157
6
0.236
9
0.354
47
1.850
57
2.244
72
2.835
Material: Stainless steel (SUS)
Two M4 (length 28 mm 1.102 in) screws with washers are attached.
28
1.102
41
1.614
3
0.118
3-M5 × 0.8 0.031
27.2
1.071
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
60
2.362
LASER
MARKERS
PLC
R4.7 R0.185
45
40 1.772
30 1.575
1.181
15
0.591
PARTICULAR
USE
SENSORS
SIMPLE
WIRE-SAVING
UNITS
2-M5 × 0.8 0.031
25
0.984
PRESSURE /
FLOW
SENSORS
STATIC
CONTROL
DEVICES
2-R5 R0.197
5
0.197
2-ø4.5 ø0.177
mounting holes
Sensor mounting bracket (Optional)
20
0.787
2-R4.7
R0.185
57
47
2.244 1.850
)
MS-LX-2
3
0.118
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
INDUCTIVE
PROXIMITY
SENSORS
35 25
1.378 0.984
ø22
ø0.866
15
0.591
LASER
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
OFF
71.5
2.815
1.5
0.059
FIBER
SENSORS
PHOTOELECTRIC
SENSORS
COLOR
TIMER
PRO
9.4
0.370
5
0.197 3
0.118
908
The CAD data can be downloaded from our website.
LX-101 LX-101-P
RUN
TEACH
ADJ
LX-100 SERIES
15
0.591
3-R2 R0.079
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
2-M4 × 0.7 0.028
57.2
2.252
2-R5
10 R0.197
0.394
47 57
1.850 2.244
4
0.157
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
R2 R0.079
4-M4 × 0.7 0.028
6
0.236
25
0.984
5
5
0.197 0.197
Material: Stainless steel (SUS)
Two M4 (length 30 mm 1.181 in) screws with washers are attached.
Selection
Guide
Liquid Leak
Detection
Liquid Level
Detection
Water
Detection
Color Mark
Detection
Wafer
Detection
Ultrasonic
Small / Slim
Object Detection
Obstacle
Detection
LX-100
FZ-10