377
Triple Beam Adjustable Range Reflective Photoelectric Sensor
MQ-W SERIES
FIBER
SENSORS
Related Information
■■General terms and conditions............ F-17
■■Glossary of terms........................ P.1359~
Amplifier Built-in
■■Sensor selection guide................... P.283~
■■General precautions...................... P.1405
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
panasonic-electric-works.net/sunx
Sensing objects can be detected at a constant distance
using the triple beam sensing method
Hardly affected by color
Hardly affected by background
Adjustable range reflective type sensor can detect white
or black object at the same distance. Therefore, the
sensor can even detect individual objects that are mixed
with black objects or objects of various colors that were
hard for the diffuse reflective type sensor to detect.
Adjustable range reflective type sensor dose not detect
objects beyond the set range.
For this reason, malfunction does not occur even if
there are moving machines or people passing by in the
background.
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
CX-400
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
However, when the background is specular, it may be
necessary to change the angle of the sensor.
ENVIRONMENTAL RESISTANCE
VARIETIES
Insusceptible to contamination on lens
Visible light type and low hysteresis type are available
Adjustable range reflective type sensor detects the
distance by the angle, not by the light receiving intensity.
Even if the lens surface is soiled by dust or any powdery
material, there is little variation of sensing range.
In addition, the sensor stably detects approaching objects
at a fixed distance because the distance is sensed by the
angle of received light.
MOUNTING / SIZE
Compact and slim size
A small size of W32 × H32 × D12.6 mm W1.260 × H1.260
× D0.496 in has been achieved for the 40 mm 1.575 in /
200 mm 7.874 in sensing range type due to the built‑in
amplifier. In addition, you can mount the sensor both
vertically and horizontally by diagonal mounting.
Visible light type
Beam axis alignment can be performed by looking at the spot light.
Low hysteresis type
Hysteresis between the ON and OFF status has been
reduced by half (compared to conventional model).
Detection precision has been further improved!
Resumption distance
Operation distance
MQ-WN3A□
Hysteresis 5 %
ON OFF
Triple Beam Adjustable Range Reflective Photoelectric Sensor
MQ-W SERIES
APPLICATIONS
378
FIBER
SENSORS
Object presence detection
The sensor detects objects that are being conveyed
with almost no influence from background objects.
Black tire sensing
Detecting the remaining amount of roll sheets
Even if roll sheet colors are changed, the sensor
can detect them at almost the same distance.
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Black tire
AREA
SENSORS
LIGHT
CURTAINS
Roller conveyor
PRESSURE /
FLOW
SENSORS
Conveyor line
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
Glossary (Performance overview of the triple beam adjustable range reflective type)
Stability Indicator
Sensing distance (rated)
• For the triple beam adjustable range reflective type, the maximum
distance to operate stably with a standard sensing object is shown.
• The MQ-W series uses PSD for light receiving elements and
since sensing is based on the position of the entering beam
and not its intensity, the output corresponds to distance. The
stability indicator displays the marginal degree of the incident
light intensity. So take note that the distance by which the
indicator lights on/off varies depending on the reflectance
of the sensing object, as shown in the diagram below. Also,
do not use the sensor when the stability indicator lights off
(Unstable light received condition).
Setting range (optimum)
• For the triple beam adjustable range reflective type, the range
between the maximum and minimum setting distance to operate
stably with a standard sensing object is shown. When used
beyond this range, there will be a non-detectable area near the
sensor. There will also be insufficient light intensity on the far
side of the sensor. This will result in unstable sensing. So when
setting the sensor, use it within the optimum setting range.
Setting Sensing
distance object
Sensing object
Optimum setting
range
Non-detectable
area
Min. setting
distance
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Operation indicator
Lights up
Lights off
Stability indicator
Stable dark condition
(Black non-glossy paper) Stable light received condition
Unstable light received condition
Lights up
Lights off
Stability indicator
(White non-glossy paper)
Max. setting
distance
SIMPLE
WIRE-SAVING
UNITS
ENDOSCOPE
Sensing
object
Sensor
Sensing object
SENSOR
OPTIONS
Lights up
Stable light received condition
Stable dark condition
Lights off
Unstable light received condition
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
ORDER GUIDE
Standard (infrared)
Low hysteresis (infrared) Visible light (red)
Triple beam adjustable range reflective type
Type
UV
CURING
SYSTEMS
Appearance
Sensing range
40 mm
1.575 in
Model No.
MQ-W3A-DC12-24V
200 mm
7.874 in
MQ-W20A-DC12-24V
700 mm
27.559 in
40 mm
1.575 in
MQ-W70A-DC12-24V
MQ-W3AR-DC12-24V
200 mm
7.874 in
40 mm
1.575 in
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
CX-400
EX-10
EX-20
MQ-W20AR-DC12-24V
EX-30
MQ-WN3A-DC12-24V
CX-440
EX-40
EQ-30
200 mm
7.874 in
MQ-WN20A-DC12-24V
EQ-500
MQ-W
700 mm
27.559 in
MQ-WN70A-DC12-24V
RX-LS200
RX
RT-610
379
Triple Beam Adjustable Range Reflective Photoelectric Sensor
SPECIFICATIONS
FIBER
SENSORS
LASER
SENSORS
Triple beam adjustable range reflective
PHOTOELECTRIC
SENSORS
Type
40 mm 1.575 in type
200 mm 7.874 in type
Visible light Low hysteresis
MICRO
PHOTOELECTRIC
SENSORS
Item
AREA
SENSORS
Sensing distance (rated)
LIGHT
CURTAINS
Setting range (optimum)
PRESSURE /
FLOW
SENSORS
MQ-W SERIES
MQ-W3A□
Basic Model No.
Visible light Low hysteresis
40 mm 1.575 in with white non-glossy paper
(10 × 10 mm 0.394 × 0.394 in)
200 mm 7.874 in with white non-glossy paper
(20 × 20 mm 0.787 × 0.787 in)
Sensing object
Opaque or translucent object (Note 2)
5 % or less of
20 % or less of operation
10 % or less of
20 % or less of
10 % or less of
10 % or less of operation
operation distance distance
operation distance operation distance operation distance
distance
(with standard sensing object) (with standard sensing object) (with standard sensing object) (with standard sensing object) (with standard sensing object) (with standard sensing object)
Hysteresis (Note 3)
Supply voltage
9.6 to 30 V DC
Current consumption
30 mA or less
MEASUREMENT
SENSORS
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.2 V or less (at 100 mA sink current)
Output
WIRE-SAVING
SYSTEMS
Output operation
Selectable either Light-ON or Dark-ON by the control input
Response time
2 ms or less (Response frequency: 250 Hz or more)
STATIC
CONTROL
DEVICES
Operation indicator
Red LED (lights up under light received condition)
Stability indicator
Red LED (lights up under stable sensing condition)
ENDOSCOPE
Distance adjuster
Continuously variable adjuster
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Protection
Environmental resistance
LASER
MARKERS
IP67 (IEC)
Ambient temperature
–25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +55 °C –13 to +131 °F
Ambient humidity
85 % RH or less, Storage: 85 % RH or less
Ambient illuminance
Incandescent light: 10,000 ℓx or less at the light-receiving face
Voltage withstandability
500 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for six times each
Shock resistance
Emitting element (modulated)
Infrared LED
Amplifier
Built-in
Power Supply
Built-in
EX-10
CX-440
EQ-30
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Accessory
Mounting bracket: 1 set
Notes: 1) Where measurement conditions have not been specified precisely, the conditions use were an ambient temperature of +23 °C +73.4 °F.
2) Make sure to confirm detection with an actual sensor before use.
3) This value is from the sensing distance (rated). The standard sensing object is non-glossy paper described in the “Sensing distance (rated)” item.
I/O CIRCUIT AND WIRING DIAGRAMS
I/O circuit diagram
Wiring diagram
Color code
(Black) Output
Tr
Brown
(Brown) +V
D
ZD
Load
100mA max.
(Blue) 0 V
(Pink) Control input
+
–
Black
9.6 to 30 V DC
RX-LS200
RX
RT-610
Internal circuit
Load
*1
+
–
Pink
9.6 to 30 V DC
*1
Blue
EQ-500
MQ-W
Infrared LED
4-core cable, 2 m 6.562 ft long
Sensor circuit
EX-40
Red LED
Cable
EX-20
EX-30
Infrared LED
Enclosure: Die-cast zinc alloy
Amplifierseparated
CX-400
Red LED
Material
Cable extension
Selection
Guide
700 mm 27.559 in with white non-glossy
paper (75 × 75 mm 2.953 × 2.953 in)
20 to 40 mm 0.787 to 1.575 in with white
40 to 200 mm 1.575 to 7.874 in with white
200 to 700 mm 7.874 to 27.559 in with white
non‑glossy paper (10 × 10 mm 0.394 × 0.394 in) non‑glossy paper (20 × 20mm 0.787 × 0.787 in) non‑glossy paper (75 × 75 mm 2.953 × 2.953 in)
PARTICULAR
USE
SENSORS
SIMPLE
WIRE-SAVING
UNITS
Low hysteresis
MQ-W3AR□ MQ-WN3A□ MQ-W20A□ MQ-W20AR□ MQ-WN20A□ MQ-W70A□ MQ-WN70A□
INDUCTIVE
PROXIMITY
SENSORS
SENSOR
OPTIONS
700 mm 27.559 in type
Users’ circuit
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : NPN output transistor
* 1: Selecting output operation by connecting control input wire (pink)
Processing
Output operation
Connected to +V
Light-ON
Connected to 0 V
Dark-ON
Triple Beam Adjustable Range Reflective Photoelectric Sensor
MQ-W SERIES
SENSING CHARACTERISTICS (TYPICAL)
FIBER
SENSORS
LASER
SENSORS
40 mm 1.575 in Type
Sensing field
Correlation between sensing object size and sensing range
Setting distance 40 mm 1.575 in
Sensing range L (mm in)
20
0.787
Setting distance 30 mm 1.181 in
10 × 10mm
0.394 × 0.394 in
White non-glossy
paper
ℓ
0
10
0.394
Setting distance 20 mm 0.787 in
L
Sensor
5
0
5
10
0.197
0.197
0.394
Left
Center
Right
Operation point ℓ (mm in)
Sensing range L (mm in)
…40 mm
1.575 in
…30 mm
1.181 in
…20 mm
0.787 in
Copper foil
Deep yellow acrylic board
(with glossy surface)
Black rubber
leather type
Plywood
Black rubber
Cardboard
0
White nonglossy paper
Black nonglossy paper
20
0.787
40
1.575
These bars indicate
the sensing range
with the respective
objects when the
distance adjuster is
set to a sensing range
of 40 mm 1.575 in,
30 mm 1.181 in and
20 mm 0.787 in long,
respectively, with
white non-glossy
paper.
Setting distance 30 mm 1.181 in
Setting distance 20 mm 0.787 in
20
0.787
5
10
15
0.197
0.394
0.591
White non-glossy paper
side length a (mm in)
20
0.787
Emitted beam
30
1.181
ø2.3 mm
ø0.091 in
20
0.787
ø2.5 mm
ø0.098 in
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
0
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
Setting distance 200 mm 7.874 in
Sensing range L (mm in)
200
7.874
Setting distance 150 mm 5.906 in
…200 mm
7.874 in
…100 mm
3.937 in
…40 mm
1.575 in
Copper foil
Deep yellow acrylic board
(with glossy surface)
Black rubber
leather type
Plywood
Black rubber
Cardboard
White nonglossy paper
Black nonglossy paper
100
3.937
Setting distance 40 mm 1.575 in
These bars indicate
the sensing range
with the respective
objects when the
distance adjuster is
set to a sensing range
of 200 mm 7.874 in,
100 mm 3.937 in and
40 mm 1.575 in long,
respectively, with
white non-glossy
paper.
Sensing object size:
35 × 60 mm 1.378 × 2.362 in.
These curves show the
characteristics with the
maximum sensing range
set to 200 mm 7.874 in,
100 mm 3.937 in and
40 mm 1.575 in, with white
non-glossy paper (20 ×
20 mm 0.787 × 0.787 in).
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
0
5
0
5
10
0.197
0.197
0.394
Left
Center
Right
Operation point ℓ (mm in)
200
7.874
Setting distance 100 mm 3.937 in
100
3.937
5
10
15
0.197
0.394
0.591
White non-glossy paper
side length a (mm in)
20
0.787
Power Supply
Built-in
Amplifierseparated
CX-400
Emitted beam
EX-10
EX-20
200
7.874
Distance L (mm in)
Setting distance L (mm in)
Sensing range L (mm in)
PARTICULAR
USE
SENSORS
ENDOSCOPE
Setting distance 200 mm 7.874 in
Correlation between material and sensing range
0
PRESSURE /
FLOW
SENSORS
WIRE-SAVING
SYSTEMS
ø4.0 mm
ø0.157 in
40
1.575
Correlation between sensing object size and sensing range
Setting distance 50 mm 1.969 in
0
10
0.394
LIGHT
CURTAINS
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Setting distance 100 mm 3.937 in
Sensor
AREA
SENSORS
SIMPLE
WIRE-SAVING
UNITS
Sensing object size:
35 × 60 mm 1.378 × 2.362 in.
Sensing field
100
3.937
MICRO
PHOTOELECTRIC
SENSORS
SENSOR
OPTIONS
200 mm 7.874 in Type
20 × 20 mm
0.787 × 0.787 in
White non-glossy
200 paper
7.874
ℓ L
PHOTOELECTRIC
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
0
Correlation between material and sensing range
40
1.575
These curves show the
characteristics with the
maximum sensing range
set to 40 mm 1.575 in,
30 mm 1.181 in and 20
mm 0.787 in, with white
non-glossy paper (10 ×
10 mm 0.394 × 0.394 in).
Setting distance 40 mm 1.575 in
Distance L (mm in)
Setting distance L (mm in)
40
1.575
380
ø8.3 mm
ø0.327 in
150
5.906
ø7.4 mm
ø0.291 in
100
3.937
ø6.9 mm
ø0.272 in
50
1.969
ø6.7 mm
ø0.264 in
0
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
381
Triple Beam Adjustable Range Reflective Photoelectric Sensor
SENSING CHARACTERISTICS (TYPICAL)
FIBER
SENSORS
200
7.874
10
0
10
20
0.394
0.394
0.787
Left
Center
Right
Operation point ℓ (mm in)
0
Correlation between material and sensing range
600
23.622
Sensing range L (mm in)
WIRE-SAVING
SYSTEMS
ENDOSCOPE
L
…700 mm
27.559 in
…400 mm
15.748 in
…200 mm
7.874 in
400
15.748
200
7.874
These bars indicate
the sensing range
with the respective
objects when the
distance adjuster is
set to a sensing range
of 700 mm 27.559 in,
400 mm 15.748 in
and 200 mm 7.874 in
long, respectively,
with white non-glossy
paper.
PLC /
TERMINALS
White nonglossy paper
Black nonglossy paper
0
HUMAN
MACHINE
INTERFACES
PRECAUTIONS FOR PROPER USE
LASER
MARKERS
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
CX-400
Emitted beam
700
27.559
500
19.685
300
11.811
ø39 mm
ø1.535 in
ø33 mm
ø1.299 in
ø23 mm
ø0.906 in
0
Refer to General precautions.
• An exclusive insulation mounting bracket is available in
order to improve the anti-noise quality in case there are
devices that produce high-frequency noise close to the
sensor and the place where the sensor is mounted is an
electric conductor (such as metal). Please contact our
office for details.
Sensor
Exclusive insulating board
Plain washer (Note)
Spring washer (Note)
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
Exclusive mounting
screw (Note)
(made from resin)
Case grounding method and insulation mounting bracket
• The MQ-W series has an internal circuit that is completely
insulated from the enclosure (floating method).
EX-20
Internal
circuit
EX-30
EX-40
EQ-30
80
3.150
Others
EX-10
CX-440
20
40
60
0.787
1.575
2.362
White non-glossy paper
side length a (mm in)
Sensing object size:
35 × 60 mm 1.378 × 2.362 in.
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
FA
COMPONENTS
Selection
Guide
Setting distance 200 mm 7.874 in
200
7.874
Distance L (mm in)
0
20
0.787
800
31.496
STATIC
CONTROL
DEVICES
Setting distance 400 mm 15.748 in
400
15.748
These curves show the
characteristics with the
maximum sensing range
set to 700 mm 27.559 in,
400 mm 15.748 in and
200 mm 7.874 in, with
white non-glossy paper
(75 × 75 mm 2.953 ×
2.953 in).
Sensor
SIMPLE
WIRE-SAVING
UNITS
MEASUREMENT
SENSORS
ℓ
Setting distance 700 mm 27.559 in
600
23.622
Setting distance 500 mm 19.685 in
75 × 75 mm
400 2.953 × 2.953 in
White
non-glossy Setting distance 300 mm 11.811 in
15.748
paper
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Sensing range L (mm in)
600
23.622
Copper foil
INDUCTIVE
PROXIMITY
SENSORS
800
31.496
Setting distance 700 mm 27.559 in
Black acrylic
PRESSURE /
FLOW
SENSORS
Correlation between sensing object size and sensing range
White acrylic
LIGHT
CURTAINS
800
31.496
Plywood
AREA
SENSORS
Sensing field
Black rubber
MICRO
PHOTOELECTRIC
SENSORS
700 mm 27.559 in Type
Cardboard
PHOTOELECTRIC
SENSORS
Setting distance L (mm in)
LASER
SENSORS
MQ-W SERIES
0V
Enclosure
Insulation (floating)
Sensor mouting bracket
(Accessory)
Note: Attached with the exclusive insulating board.
• Performing direct-grounding between the enclosure and
circuit 0 V will improve the anti-noise quality.
• Contact our office if you would like to special-order the
direct-grounding type that has the enclosure and circuit
0 V connected beforehand.
EQ-500
MQ-W
RX-LS200
Internal circuit
0V
RX
RT-610
Direct-grounding
Triple Beam Adjustable Range Reflective Photoelectric Sensor
DIMENSIONS (Unit: mm in)
MQ-W SERIES
The CAD data in the dimensions can be downloaded from our website.
MQ-W3□ MQ-WN3□
Sensor
Assembly dimensions with attached mounting bracket
12.6 12.2
0.496 0.480
3.3
1
0.039 0.130
Operation indicator (Red)
25.4
1.000
(17 0.669)
2.2
0.087 10.7
0.421
16
0.630
4.4
0.173
3.3
0.130
7.3
0.287
PHOTOELECTRIC
SENSORS
LIGHT
CURTAINS
4.4 0.173
24.4
0.961
6.3
0.248
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
ø4.2 ø0.165 cable,
2 m 6.562 ft long
11.7
0.461
LASER
SENSORS
AREA
SENSORS
2-M4 Thru-hole threads
6.3
0.248
32 25.4
6.3
0.248 1.260 1.000
FIBER
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Stability indicator (Red)
Distance adjuster
382
PARTICULAR
USE
SENSORS
44.8
1.764
24
0.945
10.9
0.429
3.3
0.130
4
16.6
4
0.157 0.654 0.157
25.4
1.000
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
t 1.4
t 0.055
WIRE-SAVING
SYSTEMS
MQ-W20□ MQ-WN20□
Sensor
Assembly dimensions with attached mounting bracket
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
Stability indicator (Red)
ENDOSCOPE
12.6 12.2
0.496 0.480
Operation indicator (Red)
Distance adjuster
3.3
1
0.039 0.130
25.4
1.000
(17 0.669)
2.2
0.087 10.7
0.421
16
0.630
4.4
0.173
3.3
0.130
7.3
0.287
4.4 0.173
24.4
0.961
LASER
MARKERS
PLC /
TERMINALS
6.3
0.248
HUMAN
MACHINE
INTERFACES
2-M4 Thru-hole threads
7.5
0.295 32
25.4
7.5 1.260 1.000
0.295
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
ø4.2 ø0.165 cable,
2 m 6.562 ft long
10.5
0.413
FA
COMPONENTS
44.8
1.764
24
0.945
10.9
0.429
3.3
0.130
4
16.6
0.157 0.654
25.4
1.000
4
0.157
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
t 1.4
t 0.055
MQ-W70□ MQ-WN70□
Sensor
Assembly dimensions with attached mounting bracket
Distance adjuster
3.5
1
0.039 0.138
45
1.772
Operation indicator (Red)
Amplifierseparated
12.7
0.500
19
0.748
4.4
0.173
3.5
0.138
9.1
0.358
ø4.5
ø0.177
4.4
0.173
44
1.732
(22 0.866)
4
0.157
8.1
0.319
2-M4 Thru-hole threads
13
0.512
CX-400
EX-10
EX-20
EX-30
EX-40
52
45
13 2.047 1.772
0.512
CX-440
12.5
0.492 68.2
2.660
12.5
0.492
ø4.2 ø0.165 cable,
2 m 6.562 ft long
15.5
0.610
Amplifier
Built-in
Power Supply
Built-in
Stability indicator (Red)
18.6 18.2
0.732 0.717
Selection
Guide
3.5
0.138
24
12.40.945
0.488
17.4
0.685
36.6 1.441
45 1.772
t 1.6
t 0.063
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610