MQ-W3CR-DC12-24VEM

MQ-W3CR-DC12-24VEM

  • 厂商:

    NAIS(松下)

  • 封装:

  • 描述:

    PHOTO SENSOR REFLECTIVE

  • 数据手册
  • 价格&库存
MQ-W3CR-DC12-24VEM 数据手册
371 Triple Beam Adjustable Range Reflective Photoelectric Sensor MQ-W SERIES FIBER SENSORS Related Information ■■General terms and conditions.............. F-7 ■■Glossary of terms........................ P.1455~ Amplifier Built-in ■■Sensor selection guide................... P.271~ ■■General precautions.................... P.1458~ LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS panasonic.net/id/pidsx/global Sensing objects can be detected at a constant distance using the triple beam sensing method Hardly affected by color Hardly affected by background Adjustable range reflective type sensor can detect white or black object at the same distance. Therefore, the sensor can even detect individual objects that are mixed with black objects or objects of various colors that were hard for the diffuse reflective type sensor to detect. Adjustable range reflective type sensor dose not detect objects beyond the set range. For this reason, malfunction does not occur even if there are moving machines or people passing by in the background. UV CURING SYSTEMS Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated CX-400 CY-100 EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 However, when the background is specular, it may be necessary to change the angle of the sensor. ENVIRONMENTAL RESISTANCE VARIETIES Insusceptible to contamination on lens Visible light type and low hysteresis type are available Adjustable range reflective type sensor detects the distance by the angle, not by the light receiving intensity. Even if the lens surface is soiled by dust or any powdery material, there is little variation of sensing range. In addition, the sensor stably detects approaching objects at a fixed distance because the distance is sensed by the angle of received light. MOUNTING / SIZE Compact and slim size A small size of W32 × H32 × D12.6 mm W1.260 × H1.260 × D0.496 in has been achieved for the 40 mm 1.575 in / 200 mm 7.874 in sensing range type due to the built‑in amplifier. In addition, you can mount the sensor both vertically and horizontally by diagonal mounting. Visible light type Beam axis alignment can be performed by looking at the spot light. Low hysteresis type Hysteresis between the ON and OFF status has been reduced by half (compared to conventional model). Detection precision has been further improved! Resumption distance Operation distance MQ-WN3A□ Hysteresis 5 % ON OFF Triple Beam Adjustable Range Reflective Photoelectric Sensor MQ-W SERIES APPLICATIONS 372 FIBER SENSORS Object presence detection The sensor detects objects that are being conveyed with almost no influence from background objects. Black tire sensing Detecting the remaining amount of roll sheets Even if roll sheet colors are changed, the sensor can detect them at almost the same distance. LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Black tire AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS Roller conveyor PRESSURE / FLOW SENSORS Conveyor line INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Glossary (Performance overview of the triple beam adjustable range reflective type) Stability Indicator Sensing distance (rated) • For the triple beam adjustable range reflective type, the maximum distance to operate stably with a standard sensing object is shown. • The MQ-W series uses PSD for light receiving elements and since sensing is based on the position of the entering beam and not its intensity, the output corresponds to distance. The stability indicator displays the marginal degree of the incident light intensity. So take note that the distance by which the indicator lights on/off varies depending on the reflectance of the sensing object, as shown in the diagram below. Also, do not use the sensor when the stability indicator lights off (Unstable light received condition). Setting range (optimum) • For the triple beam adjustable range reflective type, the range between the maximum and minimum setting distance to operate stably with a standard sensing object is shown. When used beyond this range, there will be a non-detectable area near the sensor. There will also be insufficient light intensity on the far side of the sensor. This will result in unstable sensing. So when setting the sensor, use it within the optimum setting range. Setting Sensing distance object Sensing object Optimum setting range Non-detectable area Min. setting distance Operation indicator Lights up Lights off Stability indicator Stable dark condition (Black non-glossy paper) Stable light received condition Unstable light received condition Lights up Lights off Lights up Stable light received condition Stable dark condition Lights off Unstable light received condition Standard (infrared) Triple beam adjustable range reflective type Low hysteresis (infrared) Visible light (red) MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS ORDER GUIDE Type WIRE-SAVING SYSTEMS PLC Stability indicator (White non-glossy paper) Max. setting distance SIMPLE WIRE-SAVING UNITS LASER MARKERS Sensing object Sensor Sensing object SENSOR OPTIONS Appearance Sensing range 40 mm 1.575 in Model No. MQ-W3A-DC12-24V 200 mm 7.874 in MQ-W20A-DC12-24V 700 mm 27.559 in 40 mm 1.575 in MQ-W70A-DC12-24V MQ-W3AR-DC12-24V 200 mm 7.874 in 40 mm 1.575 in Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated CX-400 CY-100 EX-10 MQ-W20AR-DC12-24V EX-20 MQ-WN3A-DC12-24V EX-40 EX-30 CX-440 200 mm 7.874 in MQ-WN20A-DC12-24V EQ-30 EQ-500 700 mm 27.559 in MQ-WN70A-DC12-24V MQ-W RX-LS200 RX RT-610 373 Triple Beam Adjustable Range Reflective Photoelectric Sensor SPECIFICATIONS FIBER SENSORS LASER SENSORS Triple beam adjustable range reflective PHOTOELECTRIC SENSORS Type Item AREA SENSORS Sensing distance (rated) PRESSURE / FLOW SENSORS 40 mm 1.575 in type 200 mm 7.874 in type Visible light Low hysteresis MICRO PHOTOELECTRIC SENSORS LIGHT CURTAINS / SAFETY COMPONENTS MQ-W SERIES MQ-W3A□ Basic Model No. Visible light Low hysteresis 40 mm 1.575 in with white non-glossy paper (10 × 10 mm 0.394 × 0.394 in) 200 mm 7.874 in with white non-glossy paper (20 × 20 mm 0.787 × 0.787 in) Sensing object Opaque or translucent object (Note 2) 10 % or less of operation 5 % or less of 20 % or less of operation 10 % or less of 20 % or less of 10 % or less of distance operation distance distance operation distance operation distance operation distance (with standard sensing object) (with standard sensing object) (with standard sensing object) (with standard sensing object) (with standard sensing object) (with standard sensing object) Hysteresis (Note 3) Supply voltage 9.6 to 30 V DC Current consumption 30 mA or less MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS Output operation FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 2 ms or less (Response frequency: 250 Hz or more) Operation indicator Red LED (lights up under light received condition) Stability indicator Red LED (lights up under stable sensing condition) Distance adjuster Continuously variable adjuster Protection Environmental resistance ENERGY CONSUMPTION VISUALIZATION COMPONENTS Selectable either Light-ON or Dark-ON by the control input Response time PLC HUMAN MACHINE INTERFACES NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.2 V or less (at 100 mA sink current) Output WIRE-SAVING SYSTEMS IP67 (IEC) Ambient temperature –25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +55 °C –13 to +131 °F Ambient humidity 85 % RH or less, Storage: 85 % RH or less Ambient illuminance Incandescent light: 10,000 ℓx or less at the light-receiving face Voltage withstandability 500 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each Shock resistance 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for six times each Emitting element (modulated) Infrared LED Amplifier Built-in Power Supply Built-in CY-100 EX-40 CX-440 Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. Accessory Mounting bracket: 1 set Notes: 1) Where measurement conditions have not been specified precisely, the conditions use were an ambient temperature of +23 °C +73.4 °F. 2) Make sure to confirm detection with an actual sensor before use. 3) This value is from the sensing distance (rated). The standard sensing object is non-glossy paper described in the “Sensing distance (rated)” item. I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram MQ-W RX-LS200 RX RT-610 Wiring diagram Color code (Black) Output Tr Brown (Brown) +V D ZD Load 100mA max. (Blue) 0 V (Pink) Control input EQ-30 EQ-500 Infrared LED 4-core cable, 2 m 6.562 ft long Sensor circuit EX-30 Red LED Cable EX-10 EX-20 Infrared LED Enclosure: Die-cast zinc alloy Amplifierseparated CX-400 Red LED Material Cable extension Selection Guide 700 mm 27.559 in with white non-glossy paper (75 × 75 mm 2.953 × 2.953 in) 20 to 40 mm 0.787 to 1.575 in with white 40 to 200 mm 1.575 to 7.874 in with white 200 to 700 mm 7.874 to 27.559 in with white non‑glossy paper (10 × 10 mm 0.394 × 0.394 in) non‑glossy paper (20 × 20mm 0.787 × 0.787 in) non‑glossy paper (75 × 75 mm 2.953 × 2.953 in) Setting range (optimum) PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS Low hysteresis MQ-W3AR□ MQ-WN3A□ MQ-W20A□ MQ-W20AR□ MQ-WN20A□ MQ-W70A□ MQ-WN70A□ INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS 700 mm 27.559 in type Internal circuit + – Black 9.6 to 30 V DC Load *1 + – Pink 9.6 to 30 V DC *1 Users’ circuit Symbols … D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : NPN output transistor Blue * 1: Selecting output operation by connecting control input wire (pink) Processing Output operation Connected to +V Light-ON Connected to 0 V Dark-ON Triple Beam Adjustable Range Reflective Photoelectric Sensor MQ-W SERIES SENSING CHARACTERISTICS (TYPICAL) FIBER SENSORS LASER SENSORS 40 mm 1.575 in Type Sensing field Correlation between sensing object size and sensing range Setting distance 40 mm 1.575 in Sensing range L (mm in) 20 0.787 Setting distance 30 mm 1.181 in 10 × 10mm 0.394 × 0.394 in White non-glossy paper ℓ 0 10 0.394 Setting distance 20 mm 0.787 in L Sensor 5 0 5 10 0.197 0.197 0.394 Left Center Right Operation point ℓ (mm in) Sensing range L (mm in) …40 mm 1.575 in …30 mm 1.181 in …20 mm 0.787 in Copper foil Deep yellow acrylic board (with glossy surface) Black rubber leather type Plywood Black rubber Cardboard 0 White nonglossy paper Black nonglossy paper 20 0.787 40 1.575 These bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 40 mm 1.575 in, 30 mm 1.181 in and 20 mm 0.787 in long, respectively, with white non-glossy paper. Setting distance 30 mm 1.181 in Setting distance 20 mm 0.787 in 20 0.787 5 10 15 0.197 0.394 0.591 White non-glossy paper side length a (mm in) 20 0.787 Emitted beam 30 1.181 ø2.3 mm ø0.091 in 20 0.787 ø2.5 mm ø0.098 in MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES PLC 0 HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Setting distance 200 mm 7.874 in Sensing range L (mm in) 200 7.874 Setting distance 150 mm 5.906 in …200 mm 7.874 in …100 mm 3.937 in …40 mm 1.575 in Copper foil Deep yellow acrylic board (with glossy surface) Black rubber leather type Plywood Black rubber Cardboard White nonglossy paper Black nonglossy paper 100 3.937 Setting distance 40 mm 1.575 in These bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 200 mm 7.874 in, 100 mm 3.937 in and 40 mm 1.575 in long, respectively, with white non-glossy paper. Sensing object size: 35 × 60 mm 1.378 × 2.362 in. These curves show the characteristics with the maximum sensing range set to 200 mm 7.874 in, 100 mm 3.937 in and 40 mm 1.575 in, with white non-glossy paper (20 × 20 mm 0.787 × 0.787 in). MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in 0 5 0 5 10 0.197 0.197 0.394 Left Center Right Operation point ℓ (mm in) 200 7.874 Setting distance 100 mm 3.937 in 100 3.937 5 10 15 0.197 0.394 0.591 White non-glossy paper side length a (mm in) 20 0.787 Power Supply Built-in Amplifierseparated CX-400 Emitted beam CY-100 EX-10 200 7.874 Distance L (mm in) Setting distance L (mm in) Sensing range L (mm in) PARTICULAR USE SENSORS LASER MARKERS Setting distance 200 mm 7.874 in Correlation between material and sensing range 0 PRESSURE / FLOW SENSORS WIRE-SAVING SYSTEMS ø4.0 mm ø0.157 in 40 1.575 Correlation between sensing object size and sensing range Setting distance 50 mm 1.969 in 0 10 0.394 LIGHT CURTAINS / SAFETY COMPONENTS FA COMPONENTS Setting distance 100 mm 3.937 in Sensor AREA SENSORS SIMPLE WIRE-SAVING UNITS Sensing object size: 35 × 60 mm 1.378 × 2.362 in. Sensing field 100 3.937 MICRO PHOTOELECTRIC SENSORS SENSOR OPTIONS 200 mm 7.874 in Type 20 × 20 mm 0.787 × 0.787 in White non-glossy 200 paper 7.874 ℓ L PHOTOELECTRIC SENSORS INDUCTIVE PROXIMITY SENSORS 0 Correlation between material and sensing range 40 1.575 These curves show the characteristics with the maximum sensing range set to 40 mm 1.575 in, 30 mm 1.181 in and 20 mm 0.787 in, with white non-glossy paper (10 × 10 mm 0.394 × 0.394 in). Setting distance 40 mm 1.575 in Distance L (mm in) Setting distance L (mm in) 40 1.575 374 ø8.3 mm ø0.327 in 150 5.906 ø7.4 mm ø0.291 in 100 3.937 ø6.9 mm ø0.272 in 50 1.969 ø6.7 mm ø0.264 in 0 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 375 Triple Beam Adjustable Range Reflective Photoelectric Sensor SENSING CHARACTERISTICS (TYPICAL) FIBER SENSORS 200 7.874 ENERGY CONSUMPTION VISUALIZATION COMPONENTS 0 200 7.874 0 UV CURING SYSTEMS Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated CY-100 EX-10 EX-20 EX-30 300 11.811 • The MQ-W series has an internal circuit that is completely insulated from the enclosure (floating method). Internal circuit ø23 mm ø0.906 in • Performing direct-grounding between the enclosure and circuit 0 V will improve the anti-noise quality. • Contact our office if you would like to special-order the direct-grounding type that has the enclosure and circuit 0 V connected beforehand. Internal circuit 0V Insulation (floating) Sensor Exclusive insulating board Plain washer (Note) Spring washer (Note) EQ-500 MQ-W Exclusive mounting screw (Note) (made from resin) RX-LS200 Sensor mouting bracket (Accessory) Note: Attached with the exclusive insulating board. Direct-grounding Others 0V • An exclusive insulation mounting bracket is available in order to improve the anti-noise quality in case there are devices that produce high-frequency noise close to the sensor and the place where the sensor is mounted is an electric conductor (such as metal). Please contact our office for details. EQ-30 ø33 mm ø1.299 in 0 Case grounding method and insulation mounting bracket CX-440 RT-610 500 19.685 ø39 mm ø1.535 in Refer to p.1458~ for general precautions. • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. EX-40 RX 700 27.559 PRECAUTIONS FOR PROPER USE Enclosure CX-400 80 3.150 Sensing object size: 35 × 60 mm 1.378 × 2.362 in. FA COMPONENTS MACHINE VISION SYSTEMS 20 40 60 0.787 1.575 2.362 White non-glossy paper side length a (mm in) Emitted beam These bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 700 mm 27.559 in, 400 mm 15.748 in and 200 mm 7.874 in long, respectively, with white non-glossy paper. …700 mm 27.559 in …400 mm 15.748 in …200 mm 7.874 in 400 15.748 White nonglossy paper Black nonglossy paper HUMAN MACHINE INTERFACES Sensing range L (mm in) 600 23.622 PLC 10 0 10 20 0.394 0.394 0.787 Left Center Right Operation point ℓ (mm in) Correlation between material and sensing range WIRE-SAVING SYSTEMS LASER MARKERS L Setting distance 200 mm 7.874 in 200 7.874 Distance L (mm in) 0 20 0.787 800 31.496 STATIC ELECTRICITY PREVENTION DEVICES Setting distance 400 mm 15.748 in 400 15.748 These curves show the characteristics with the maximum sensing range set to 700 mm 27.559 in, 400 mm 15.748 in and 200 mm 7.874 in, with white non-glossy paper (75 × 75 mm 2.953 × 2.953 in). Sensor SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS ℓ Setting distance 700 mm 27.559 in 600 23.622 Setting distance 500 mm 19.685 in 75 × 75 mm 400 2.953 × 2.953 in White non-glossy Setting distance 300 mm 11.811 in 15.748 paper PARTICULAR USE SENSORS SENSOR OPTIONS Sensing range L (mm in) 600 23.622 Copper foil INDUCTIVE PROXIMITY SENSORS 800 31.496 Setting distance 700 mm 27.559 in Black acrylic PRESSURE / FLOW SENSORS Correlation between sensing object size and sensing range White acrylic LIGHT CURTAINS / SAFETY COMPONENTS 800 31.496 Plywood AREA SENSORS Sensing field Black rubber MICRO PHOTOELECTRIC SENSORS 700 mm 27.559 in Type Cardboard PHOTOELECTRIC SENSORS Setting distance L (mm in) LASER SENSORS MQ-W SERIES • Do not use during the initial transient time (50 ms) after the power supply is switched on. Triple Beam Adjustable Range Reflective Photoelectric Sensor DIMENSIONS (Unit: mm in) MQ-W SERIES The CAD data in the dimensions can be downloaded from our website. MQ-W3□  MQ-WN3□ Sensor Assembly dimensions with attached mounting bracket 12.6 12.2 0.496 0.480 3.3 1 0.039 0.130 Operation indicator (Red) 25.4 1.000 (17 0.669) 2.2 0.087 10.7 0.421 16 0.630 4.4 0.173 3.3 0.130 4.4 0.173 24.4 7.3 0.961 0.287 6.3 0.248 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS 44.8 1.764 24 0.945 10.9 0.429 3.3 0.130 4 16.6 4 0.157 0.654 0.157 25.4 1.000 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS t 1.4 t 0.055 WIRE-SAVING SYSTEMS MQ-W20□  MQ-WN20□ Sensor Assembly dimensions with attached mounting bracket Stability indicator (Red) 12.6 12.2 0.496 0.480 Operation indicator (Red) Distance adjuster 3.3 1 0.039 0.130 25.4 1.000 (17 0.669) 2.2 0.087 10.7 0.421 16 0.630 4.4 0.173 3.3 0.130 7.3 0.287 4.4 0.173 24.4 0.961 HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS 44.8 1.764 24 0.945 10.9 0.429 3.3 0.130 4 16.6 0.157 0.654 25.4 1.000 4 0.157 UV CURING SYSTEMS t 1.4 t 0.055 MQ-W70□  MQ-WN70□ Sensor Assembly dimensions with attached mounting bracket Distance adjuster 3.5 1 0.039 0.138 45 1.772 Operation indicator (Red) 12.7 0.500 19 0.748 9.1 0.358 ø4.5 ø0.177 4.4 0.173 44 1.732 (22 0.866) 4 0.157 8.1 0.319 2-M4 Thru-hole threads 13 0.512 CX-400 CY-100 EX-10 EX-20 EX-30 52 45 13 2.047 1.772 0.512 EX-40 12.5 0.492 68.2 2.660 12.5 0.492 ø4.2 ø0.165 cable, 2 m 6.562 ft long 15.5 0.610 Amplifier Built-in Amplifierseparated 4.4 0.173 3.5 0.138 Selection Guide Power Supply Built-in Stability indicator (Red) 18.6 18.2 0.732 0.717 STATIC ELECTRICITY PREVENTION DEVICES PLC 6.3 0.248 ø4.2 ø0.165 cable, 2 m 6.562 ft long 10.5 0.413 MEASUREMENT SENSORS LASER MARKERS 2-M4 Thru-hole threads 7.5 0.295 32 25.4 7.5 1.260 1.000 0.295 PHOTOELECTRIC SENSORS LIGHT CURTAINS / SAFETY COMPONENTS ø4.2 ø0.165 cable, 2 m 6.562 ft long 11.7 0.461 LASER SENSORS AREA SENSORS 2-M4 Thru-hole threads 6.3 0.248 32 25.4 6.3 0.248 1.260 1.000 FIBER SENSORS MICRO PHOTOELECTRIC SENSORS Stability indicator (Red) Distance adjuster 376 3.5 0.138 24 12.40.945 0.488 17.4 0.685 36.6 1.441 45 1.772 t 1.6 t 0.063 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610
MQ-W3CR-DC12-24VEM 价格&库存

很抱歉,暂时无法提供与“MQ-W3CR-DC12-24VEM”相匹配的价格&库存,您可以联系我们找货

免费人工找货