0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MS-SL-2

MS-SL-2

  • 厂商:

    NAIS(松下)

  • 封装:

    Module

  • 描述:

    DIN RAIL ADAPTER FOR SL-T

  • 数据手册
  • 价格&库存
MS-SL-2 数据手册
Sensor & Wire-saving Link System S-LINK S-LINK V Wire-saving System SYSTEMS S-LINK LP-200 LP-F10 Laser Marker S-LINK transmits 128 points on two signal lines, and ‘T’-branch multi-drop system enabling flexible cable layout This product is introduced to only limited countries. Please contact our office for details. Conforming to EMC Directive (Excluding some components) We’ve realized a wire-saving system that’s easy to use Remote I/O Just with the wire-saving between the PLC and the sub-stations, you’ll be able to save a mountain of I/O device connection wires. 1030 S-LINK The remote I/O is one-dimensional wiring Allows for great wire-saving for all connections. Installation is made easy with no faulty wiring. The power supply line can also be wired up together enabling true wire-saving for I/O devices. The S-LINK is two-dimensional wiring Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com Via PLC I/O connectors, it can be linked to various PLCs from any maker. Also available is a control unit enabling a direct connection with any PLC bus line. We’ve provided a PCI bus, ISA bus, C bus (PC/FC-98 Series), PC/104 bus, Compact PCI bus, and VME bus compatible computer control board. Also corresponds to the open network, which is growing fast throughout the globe. In addition, S-LINK compatible controllers made by partner makers are consistently being introduced onto the market. Refer to ‘SYSTEM LAYOUT’ on p.1038l or the S-LINK partner maker information page on p.1051 for more details. About 60 types of S-LINK I/O devices are made available enabling various devices to be easily connected in any location with great wire-saving. In addition, S-LINK compatible I/O devices made by partner makers are consistently being introduced onto the market. Refer to ‘SYSTEM LAYOUT’ on p.1038l or the S-LINK partner maker information page on p.1051 for more details. Programming unnecessary Commercially available cables can also be used The S-LINK can be setup with just hardware connections rendering specialized programming knowledge unnecessary. Anyone can use it with ease. You can use, apart from specially made 4-core cables, commercially available cables such as flexible, heat-resistant, or fluorine resin sheath cables singly or in combination (conductor cross-section area 0.5 to 1.25 mm2, the SL-TW series has a conductor cross-section area of 0.5 to 0.75 mm2). Flat cable Cabtyre cable Upper-level network connection possible Because it can be connected to any main open network, long-distance and multi-point transmission networks can be constructed enabling a greatly enhanced network upgrade. Also, by wiring up scattered bit-oriented I/O devices that include mostly connected sensors and switches, an efficient wire-saving layout can be realized. If exporting equipment that was setup with any open network, it can be made to correspond to different networks just by installing an S-LINK gateway controller with the entire S-LINK system left as it is. S ES DR AD F OF K. CH B0 T B1~ 31 OU 0 63 32~ 95 64~ 127 96~F OF ON N RUS. SYD. AD IN . AT ST T SE ND SE 1 ER 3 ER BK BU SH I. WH 4 ER RD 1 0 32 16 8 4 2 1 B TE 24 0 D G ID A 24 0 F OF ON G 24 0 NK S-LI R LLE TRO Y CON EWA GAT SL -G U1 -D AN JAP 05 N8Q S-LINK gateway controller Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 1031 SYSTEMS Fully functional S-LINK I/O device lineup Wire-saving System S-LINK S-LINK V Various PLCs and PCs can be utilized Laser Marker LP-200 LP-F10 S-LINK SYSTEMS S-LINK Wire-saving for analog devices also possible SL-TBAD4/TBDA1 Also available is the A/D conversion function equipped SL-TBAD4 and the D/A conversion function equipped SL-TBDA1 enabling easy analog device wire-saving. LP-200 LP-F10 Laser Marker S-LINK S-LINK V Wire-saving System The analog output arrayed terminal unit SL-TBDA1 (1 channel) Wire-saving also possible in areas prone to water splashes Available is the SL-TW series environment resistant I/O units that can be used even in areas prone to water exposure. An IP67 protective construction (IEC 60529) casing has been realized. Because they are equipped with waterproof connectors, they can be used safely even where water splashes may occur.  Protective enclosure IP67  Easy wiring with exclusive water-resistant connector The analog input arrayed terminal unit SL-TBAD4 (4 channel) Inverter, electropneumatic converter, etc. Composite male connector Pressure gauge, flowmeter, displacement gauge, etc. SL-TW series Branch connector  A high resolution of 1/4,000 (12 bits)  Equipped with an average processing function  Fast data conversion 0.8 ms approx. Labor-saving sensor connection to the power supply SL-T8PW Provided are 8-branch connector tap SL-T8PW units that can link up to 8 thru-beam type photoelectric sensor emitters via snap male connectors. Supplying power to the emitters can be done in an efficient, wire-saving manner without wasting I/O unit points or installing separate wiring. Connecting S-LINK I/O devices also possible. Conforms to CE marking Because it conforms to CE marking (EMC directive), it can be used even in Europe. Conforming to EMC Directive (Excluding some components) SL-T8PW 8-branch The emitter of the connector tap thru-beam type photoelectric sensor High noise immunity Specifies malfunctioning S-LINK I/O devices Large voltage amplitude (24 V) and wide pulse width (35 !s) signal transmissions make for units less prone to impulse noise effects with no code errors. We’ve realized the industry’s highest level of noise proofing enabling them to be used even in worksites with conventional, high-priced optical communication remote I/O units. In the event that verification cannot be obtained from an S-LINK I/O unit, such as if the main cable is cutoff, the address of the particular unverifiable I/O unit is specified and displayed allowing equipment recovery time to be greatly reduced. Highly efficient transmission Equipped with an output hold function These units use a simple transmission format that covers most I/O data transmission signals enabling a delayed transmission time of approx. 11 ms for 128 points. (Of course, the fewer the point count means less delay time) S-LINK output devices are equipped with an output hold function. When the signal transmission line is shutdown, the output status values immediately prior to the malfunction are stored greatly reducing the effect on the output devices. [Excluding SL-CH(-PN)] 1032 Address display Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com Plug-in connection The transmission line connection is realized via T-branch multi-drop wiring with hook-up connectors. Adding devices is rendered easy and maintenance is easy. The plug-in connection of sensors achieves wiresaving. Layout-free Because S-LINK I/O devices can be connected to any arbitrary main cable / branch cable location, a universal layout is possible greatly decreasing the design workload. Plug-in units Amplifier-separated photoelectric sensor Amplifier-separated inductive proximity sensor Input terminal unit Laser Marker LP-200 LP-F10 Fiber sensor SYSTEMS T-branch connector hookup to transmission lines Wire-saving System S-LINK S-LINK V S-LINK Simple and reliable connections We’ve provided all types of hook-up connectors. Connections from S-LINK I/O devices to the main cable and from sensors and other devices to S-LINK I/O devices are all realized with one-touch hook-up connectors. They can be connected anywhere quickly and maintenance is easy. Branch cable to main cable connection and S-LINK I/O device to main cable connection Connection from various connected units to S-LINK I/O devices mThe values in ( ) represent conductor cross-section areas. mThe values in ( ) represent conductor cross-section areas. SL-CP1 (0.08 to 0.2 mm2) SL-CP2 (0.3 mm2) SL-CP3 (0.5 mm2) mm2) SL-J1A SL-CP2 (0.3 SL-CP3 (0.5 mm2) SL-CJ1 (0.08 to 0.2 mm2) SL-CJ2 (0.3 mm2) SL-JK (For cable end) SL-JK1 (For ‘T’-branch) In addition, to enhance the reliability of the crimping, S-LINK exclusive pliers are made available so that anyone can do it with ease. SL-T8J SL-BMJ Connected device extensions mThe values in ( ) represent conductor cross-section areas. 4-pin type 2-pin type SL-CP1 (0.08 to 0.2 mm2) SL-CP2 (0.3 mm2) SL-CP3 (0.5 mm2) SL-CP12 (0.08 to 0.2 mm2) SL-CP22 (0.3 mm2) Exclusive pliers SL-CJ1 (0.08 to 0.2 mm2) SL-CJ2 (0.3 mm2) SL-JK (0.5 mm2) SL-CJ12 (0.08 to 0.2 mm2) SL-CJ22 (0.3 mm2) Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 1033 SYSTEMS S-LINK S-LINK V Wire-saving System LP-200 LP-F10 Laser Marker S-LINK Direct main cable connecting of sensors and actuators possible All types of transmission line direct-connecting type sensors are made available. Even partner makers are putting on the market manifold electromagnetic valves and limit switches that can be directly connected with the S-LINK system making wire-saving and labor-saving a reality. S-LINK direct hook-up area sensor SL-N15 Items offered by partner makers Limit switch Ultrasonic sensors Manifold electromagnetic Manifold electromagnetic manufactured by Matsushita manufactured by Matsushita valve manufactured by valve manufactured by Electric Works, Ltd. Electric Works, Ltd. Koganei Corp. SMC Pneumatics S-LINK direct hook-up photoelectric sensor SL-A series Manifold electromagnetic Component indicator lamp valve manufactured by manufactured by Yazaki CKD Corp. Industrial Chemical Co., Ltd. Mid-system main / branch cable installation and removal possible For conveyors or other large scale equipment, transport can also be done after dividing the whole into units of several meters in length right at the factory. Then, reassembly and wiring can be effectuated onsite afterwards. Because the S-LINK can be easily divided even from mid-system main / branch cables with the help of commercially available connectors and terminals, the segmented equipment can be wired up prior to transport. Once onsite, assembly work is all but complete with just the connecting of the individual units to each other. In addition, when assembling the equipment, the S-LINK can work even disconnected from the PLC enabling software (PLC programming) and hardware (machine assembly, I/O check) work to be done concurrently, which results in quick delivery time. With the handy monitor, I/O devices can be checked for each piece of equipment separately enabling subcontractors to conduct check work on delivery. This results in a total delivery deadline reduction and clearly defined subcontractor responsibilities. Also, checking can be performed even without programming so you’ll know immediately if malfunctions are coming from the PLC or the S-LINK. Dividing equipment into subunits possible Equipment 4 S-LINK I/O device S-LINK controller Equipment 1 Equipment 2 Commercially available connectors Equipment 3 Individual equipment subunits can be checked separately Checking inputs / outputs is easy. Handy monitor SL-HM1 1034 Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com Auxiliary materials reduced By introducing the S-LINK, you can reduce the total cost of system construction to one-fifth. Total costs including for materials go down dramatically and, by decreasing the workload, construction time is lessened which means you can easily meet that tough deadline. The S-LINK system: • A hardware-only construction makes layout design simple • With hook-up connectors, construction time is greatly reduced • Layout modifications made easy • Equipment divided into separate segments make for easy debugging • Segmented equipment can be easily interlinked with commercially available connectors Great reductions in auxiliary materials such as cable racks, cable ducts, intermediate terminal blocks, and cables. This system also contributes greatly to the reduction waste caused by cutting cable ends. Design Construction Debug Shipment and setup Design Construction Debug Shipment and setup S-LINK Construction time greatly reduced Space-saving Because of great reductions in the amount of intermediate terminal blocks and cables needed, you can save space and minimize the size of your control board and machines. This will finally let you put all that wasted space to good use. The control box can be of smaller size Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 1035 Laser Marker LP-200 LP-F10 Conventional Wire-saving System S-LINK S-LINK V Total cost reductions and great savings in setup time SYSTEMS S-LINK SYSTEMS S-LINK APPLICATIONS Distributed installation Automatic storage LP-200 LP-F10 Laser Marker S-LINK S-LINK V Wire-saving System Because conveyors have multiple I/O device points, wire-saving and construction efficiency are the key to lowering overall costs. Other systems may be wire-saving but if they can’t prove useful for longdistance distribution lines or be reliable, then they are useless. On this point, the S-LINK system offers a total wiring length of 400 m 1312.336 ft, 800 m 2624.672 ft when using booster, with reliable T-branch I/O device connections that can be mounted in any desired location. Because T-branching renders layout designing simple, not only is it a wiresaving and construction efficient system, but you can even save time in the actual design stage. In addition, you can divide main and branch cables in mid-system with commercially available connectors and terminals so the time it takes to setup your conveyor decreases greatly. Easy hook-up Parking garage Display panel control 12 34 51 62 12 Personal computer Sensor 73 84 12 34 51 62 34 73 84 Sensor 12 Sensor 34 Sensor The S-LINK system is very suitable to wire up car detection sensors in a large parking garage. It reduces wires and installation time. 1036 Display equipment can be mounted in automobile production lines to notify operators when malfunctions occur or just to keep a reliable count of units in each line. Because each type of display equipment shows variegated data, they necessitate a great amount of wiring. This wiring must be conducted in very large factories requiring a substantial amount of cables and wires. A wire-saving system in this situation would be most effective. Using the S-LINK system means that even display equipment can be wired up with just one flat cable clearing up all the bulky wiring inside the display panels themselves and realizing great material cost savings as well as a reduced workload. Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com APPLICATIONS Integrated installation Turntable Wire-saving systems are being greatly emphasized even for assembly lines peppered with multiple I/O devices. Also, to enhance productibility, using a wire-saving system is the key to reliability and avoiding the occurrence of troubles. In the S-LINK loop wiring, the system maintains signal transmission even when the loop may break at any one place. In the S-LINK standard wiring, the controller reveals disconnected device addresses when the signal transmission line may break. Further, even if excess current may flow by a short-circuit between the signal transmission lines, the controller shuts down the entire system. S-LINK is a wire-saving system optimal for automatic assembly machinery. Wiring I/O devices mounted on a rotating board (turntable) can prove to be quite a difficult task. That’s because a slip ring that has just as many terminals as wires has to be used. Therefore, developing a large-scale slip ring with a reduced I/O point count was our challenge. S-LINK enables the connection of up to 128 I/O points on a 4-pole slip ring. A compact slip ring can be used without worrying about I/O points. Handler Parts delivery system The handler in IC test equipment uses multiple sensors. For this reason, reducing wires or making them more compact as well as lowering cost or minimizing equipment are lingering issues. S-LINK makes wire-saving and space-saving a reality and solves these problems all at once. Parts delivery system utilize many small picking sensors that verify the selection of components by personnel. The inputs equal the number of shelves and if job indicators are used, there are an equal number of outputs. The S-LINK system wires up all the picking sensors with effective space and wire saving. Also, adding more boxes is made easy. Laser Marker LP-200 LP-F10 Wire-saving System S-LINK S-LINK V Automatic assembly machine SYSTEMS S-LINK Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 1037 SYSTEMS S-LINK SYSTEM LAYOUT S-LINK S-LINK V Wire-saving System PLC LP-200 LP-F10 Laser Marker Upper-level control devices PLC (Direct connection to PLC bus) S-LINK control components PLC I/O connectors (connectable PLC) SL-S, SL-P Multi-core cable PLC I/O units (screw-on terminal type PLC) SL-S, SL-SP, SL-P, SL-PP Booster SL-BS1A S-LINK controller SL-CU1A S-LINK controller for direct connection to PLC bus / S-LINK control boards For Matsushita Electric Works, Ltd. For Mitsubishi Electric Corp. PLC FP3/FP10SH PLC MELSEC-Q series SL-FP3 SL-MEL-Q For Yokogawa Electric Corp. PLC FA-M3 series SL-FAM3 Items offered by partner makers Controllers manufactured by Matsushita Electric Works, Ltd. FP0-SL1 For Matsushita Electric Works, Ltd. PLC FP-C SL-FPC Personal Computers Open network compatible PLC FP2-SL2 For ISA bus SL-PCAT For PC/104 bus SL-PC104 For compact PCI bus SL-CPCI For CC-Link SL-GU1-C For Device Net SL-GU1-D For C bus SL-PC98 For PROFIBUS-DP SL-GU1-P PCOPCN-1 / RS-485 compatible master station board 1038 Controllers manufactured by Toyoda Machine Works, Ltd. THU-5291 For Sharp Manufacturing Systems Corp. J-board Z-300 series SL-Z300 For PCI bus SL-PCI Master board for PC/AT SL-PCAT-485 Controllers manufactured by Mitsubishi Electric Corp. FP2-C1SL A1SJ71SL92N Master board for PC/FC-98 series SL-PC98-485 Master board for PC/104 bus SL-PC104-485 For VME bus SL-VMES2 For INTERBUS SL-GU1-I For OPCN-1 / RS-485 SL-CU1-485 S-LINK gateway controller for OPCN-1 / RS-485 SL-CU1-485 Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com SYSTEM LAYOUT SYSTEMS S-LINK Analog I/O arrayed terminal unit SL-TBAD4, SL-TBDA1 Environment resistant I/O unit SL-TW(-PN) 4 inputs 1 output 1 • 2 channel I/O unit SL-CH(-PN) 8 channel snap-connector I/O unit SL-T8J(-PN), SL-TP8J(-PN) I/O arrayed terminal unit SL-TB(-PN), SL-TBP(-PN) SL-TBP-TY Relay output terminal unit SL-TPR4, SL-TPR8 Wire-saving System S-LINK S-LINK V S-LINK I/O devices 16 channel MIL connector I/O unit SL-T16C1(-PN), SL-TP16C1(-PN) 8-branch connector tap SL-T8PW Laser Marker LP-200 LP-F10 4 or 8 inputs 4 outputs 2 inputs and 2 outputs 4, 8 or 16 inputs 4, 8 or 16 outputs Snap-connector sensor block SL-BMJ, SL-BXJ Plug-in unit sensor block SL-BM, SL-BX S-LINK direct hook-up photoelectric sensor SL-A S-LINK direct hook-up picking sensor SL-N15 Items offered by partner makers Limit switch manufactured by Matsushita Electric Works, Ltd. Manifold electromagnetic valve Manifold electromagnetic valve Ultrasonic sensors Manifold electromagnetic valve manufactured by Koganei Corp. manufactured by SMC Pneumatics manufactured by CKD Corp. manufactured by Matsushita Electric Works, Ltd. Component indicator lamp manufactured by Yazaki Industrial Chemical Co., Ltd. Plug-in units (for SL-BM, SL-BX) Fiber sensor • FX-D1J • FX-A1J • FX-M1J Amplifier-separated photoelectric sensor SU-7J Amplifier-separated inductive proximity sensor GA-14J/15J Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com Input terminal unit SL-TJ1 1039 SYSTEMS S-LINK SYSTEM LAYOUT S-LINK V S-LINK Wire-saving System Connectors and cables SL-TPR4 SL-TPR8 SL-J1A [‘T’-branch 4-core flat cables] SL-CH(-PN) SL-T8PW SL-T8J(-PN) SL-TP8J(-PN) SL-CP1, SL-CP2 or SL-CP3 Connect a thru-beam type photoelectric sensor emitter or an S-LINK I/O device to the SL-T8PW SL-T16C1(-PN) SL-TP16C1(-PN) IN/OU T SEND SL X SUN -C X H1 OFF 21 4 8 16 32 64 ADDR ESS SL-JK1 ‘T’-branch an S-LINK I/O device fitted with either a 0.3mm2 cabtyre cable or a flat cable to the main or branch cable in mid-system MIL connector SL-CP2 or SL-CP3 1 2 3 SL-BM SL-N15 4 LP-F10 LP-200 Laser Marker SL-A SL-T8J(-PN) SL-TP8J(-PN) SL-CP1, SL-CP2 or SL-CP3 Connect an I/O device to the SL-T8J(-PN)/TP8J(-PN) SL-TPR4 SL-TPR8 SL-T8J(-PN) SL-TP8J(-PN) SL-BMJ Limit switch for S-LINK SL-RCM100 SL-RCM200 [S-LINK exclusive 4-core flat cable] SL-J3A [Flat cable extension] SL-CJ1 or SL-CJ2 Connect an input device to the SL-BMJ SL-BMJ SL-CH2(-PN) ADDR ESS SL X SUN -C X H1 OFF 21 4 8 16 32 64 SEND IN/OU T SIDE IO SL-WP SL-JK1 SL-CP1, SL-CP2 or SL-CP3 SL-A SL-CP2 [Cascade wiring ] SL-JK [Connect an I/O device to the SL-CH2(-PN)] [Cable extension] SL-WJ8 SL-WE [Main cable end terminal only] SL-WJ8 SL-CP1, SL-CP2 or SL-CP3 SL-CJ2 SL-TW SL-CP3 SL-JK1 SL-WY SL-WP8 SL-JK Connection S-LINK I/O device fitted with either a 0.3mm2 cabtyre cable or a flat cable to the main or branch cable end-terminal SL-CP2 or SL-CP3 SL-JE SL-BM [‘T’-branch] SL-WJ8 SL-WE [Main cable end terminal only] SL-N15 SL-A [For main cable terminal] Limit switch for S-LINK SL-BMJ SL-TB(-PN) SL-TBP(-PN) SL-TBP-TY [2-wire device cable extension] 2-wire device SL-CP1 1 SL-TPR4 SL-TPR8 SL-CJ1 2 To S-LINK input unit SL-T8J(-PN) SL-TP8J(-PN) [For main cable end terminal] (When using a cabtyre cable) SL-JE-RC Other S-LINK devices I/O modules SL-M, SL-MF 8 or 16 inputs 8 or 16 outputs 4 inputs and 4 outputs 1040 Handy monitor SL-HM1 Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com ORDER GUIDE S-LINK control units Model No. Description S-LINK controller SL-CU1A It supplies the synchronization signal to the complete system to send and receive I/O data from external devices correctly. It also monitors the signal transmission line, and specifies the addresses of the disconnected devices if the line breaks, etc. Matsushita Electric Works PLC bus S-LINK controller SL-FP3 It can be directly connected to the bus line of the FP3, FP10S or FP10SH series PLCs manufactured by Matsushita Electric Works, Ltd. Has S-LINK controller as well as PLC input and output connector functions so you don’t have to prepare for these items. Also, it doesn’t need a PLC input or output module. Mitsubishi Electric PLC bus S-LINK controller SL-MEL-Q It can be directly connected to the bus line of the MELSEC-Q series PLC manufactured by Mitsubishi Electric Corp. Has S-LINK controller as well as PLC input and output connector functions so you don’t have to prepare for these items. Also, it doesn’t need a PLC input or output module. Yokogawa Electric PLC bus S-LINK controller SL-FAM3 It can be directly connected to the bus line of the FA-M3 series PLC manufactured by Yokogawa Electric Corp. Has S-LINK controller as well as PLC input and output connector functions so you don’t have to prepare for these items. Also, it doesn’t need a PLC input or output module. Matsushita Electric Works PLC bus S-LINK control board SL-FPC It can be directly connected to the bus line of the FP-C board type PLC manufactured by Matsushita Electric Works, Ltd. Has S-LINK controller as well as PLC input and output connector functions so you don’t have to prepare for these items. Also, it doesn’t need a PLC input or output module. Sharp Manufacturing Systems PLC bus S-LINK control board SL-Z300 It can be directly connected to the bus line of the J-board Z-300 series board type PLC manufactured by Sharp Manufacturing Systems Corp. Has S-LINK controller as well as PLC input and output connector functions so you don’t have to prepare for these items. Also, it doesn’t need a PLC input or output module. PCI bus S-LINK control board SL-PCI It can be fitted into the expansion slot (PCI bus) of a personal computer to control the S-LINK system. Has S-LINK controller as well as PLC input and output connector functions so you don’t have to prepare for these items. PC/AT S-LINK control board SL-PCAT It can be fitted into the expansion slot (ISA bus) of PC/AT series or compatible to control the S-LINK system. Has S-LINK controller as well as PLC input and output connector functions so you don’t have to prepare for these items. PC/FC-98 series S-LINK control board SL-PC98 It can be fitted into the expansion slot (C bus) of PC/FC-98 series to control the S-LINK system. Has S-LINK controller as well as PLC input and output connector functions so you don’t have to prepare for these items. VME bus S-LINK control board SL-VMES2 It can be directly connected to the VME bus line to control the S-LINK system. It provides two S-LINK ports, each allowing 128 I/O points maximum, so that a total of 256 I/O points can be controlled. Has S-LINK controller as well as PLC input and output connector functions so you don’t have to prepare for these items. PC/104 bus S-LINK control board SL-PC104 Controls the S-LINK system by directly coupling (stack) the PC/104 bus line to a PC/104 bus compatible PC board or panel computer. Has S-LINK controller as well as PLC input and output connector functions so you don’t have to prepare for these items. Compact PCI S-LINK control board SL-CPCI It can be directly connected to the Compact PCI bus line to control the S-LINK system. Has S-LINK controller as well as PLC input and output connector functions so you don’t have to prepare for these items. ( ( ( ( ( ( ( ( ( ( ( ) ) ) ) ) ) ) ) ) ) ) Note: Components with ‘ ’ mark conform to the CE marking EMC Directive. The following condition must be met to conform to EN 61000-6-2. • Conditions Note: 1 Cable length between the main power supply and the controller should be less than 10 m 32.808 ft. Note: 2 When the power is supplied from S-LINK controller to I/O devices at a cable distance of more than 10 m 32.808 ft add a surge absorber between 24 V and 0 V at a cable distance of less than 10 m 32.808 ft. Note: 3 Use a local power supply at a cable distance of less than 10 m 32.808 ft from each I/O device. Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 1041 Wire-saving System S-LINK S-LINK V Appearance (Note) Laser Marker LP-200 LP-F10 Designation SYSTEMS S-LINK SYSTEMS S-LINK ORDER GUIDE Products for open network Appearance (Note) Model No. Description S-LINK gateway controller for CCLink SL-GU1-C S-LINK gateway controller for connection to open network CC-Link, promoted by Mitsubishi Electric Corp. S-LINK gateway controller for DeviceNet SL-GU1-D S-LINK gateway controller for connection to open network DeviceNet. S-LINK gateway controller for PROFIBUS-DP SL-GU1-P S-LINK gateway controller for connection to open network PROFIBUS-DP. S-LINK gateway controller for INTERBUS SL-GU1-I S-LINK gateway controller for connection to open network INTERBUS. S-LINK gateway controller for OPCN-1 / RS-485 SL-CU1-485 It incorporates S-LINK system control functions and slave functions conforming to OPCN-1 or RS-485 so that it can connect an S-LINK system to a OPCN-1 or RS-485 communication system. SL-PCAT-485 It can be installed in the extension slot (ISA bus) of a PC/AT or compatible so that the personal computer can be used as a OPCN-1 master. It incorporates the S-LINK mode (for RS-485 communication) which enables easy control of the S-LINK system and the OPCN-1 mode which enables control of OPCN-1 conforming devices. SL-PC98-485 It can be installed in the extension slot (C bus) of an PC/FC-98 series so that the personal computer can be used as a OPCN-1 master. It incorporates the S-LINK mode (for RS-485 communication) which enables easy control of the S-LINK system and the OPCN-1 mode which enables control of OPCN-1 conforming devices. SL-PC104-485 It can be installed in the personal computer or board computer of a PC/104 bus so that the personal computer or board computer can be used as a OPCN-1 master. It incorporates the S-LINK mode (for RS-485 communication) which enables easy control of the S-LINK system and the OPCN-1 mode which enables control of OPCN-1 conforming devices. OPCN-1 / RS-485 master board for PC/AT OPCN-1 / RS-485 master board for PC/FC-98 series OPCN-1 / RS-485 master board for PC/104 bus Note: Components with ‘ ’ mark conform to the CE marking EMC Directive. The following condition must be met to conform to EN 61000-6-2. • Conditions Note: 1 Cable length between the main power supply and the controller should be less than 10 m 32.808 ft. Note: 2 When the power is supplied from S-LINK controller to I/O devices at a cable distance of more than 10 m 32.808 ft add a surge absorber between 24 V and 0 V at a cable distance of less than 10 m 32.808 ft. Note: 3 Use a local power supply at a cable distance of less than 10 m 32.808 ft from each I/O device. PLC related units Designation Multi-core cable PLC I/O unit Multi-core cable Appearance (Note 1) PNP type NPN type LP-F10 LP-200 Laser Marker S-LINK V S-LINK Wire-saving System Designation PLC Multi-core cable PLC I/O unit Model No. For input For output SL-S SL-P SL-SP SL-PP Multi-core cable SL-L2000F Description This is the Multi-core cable PLC I/O unit for connecting the screw-on terminal type PLC with the S-LINK system. Interfaces I/O data between the S-LINK controller and PLC. It includes the I/O data conversion circuit for serial to parallel or parallel to serial conversion. I/O points: 32 points per unit Connection to screw-on terminal type PLC is by an optional multi-core cable attached with an MIL connector on one end. The multi-core cable attached with an MIL connector Length: 2 m on one end links the multi-core cable PLC I/O unit to 6.562 ft a screw-on terminal type PLC I/O module. Notes: 1) Components with ‘ ’ mark conform to the CE marking EMC Directive. However, note that for the multi-core cable PLC I/O units to conform to CE marking EMC Directive, it is necessary to use cascade cable SL-F70, SL-F150 or SL-F250, control cable SL-C2000F and multi-core cable SL-L2000F. Notes: 2) In case the output circuit of the PLC output module contains capacitive components for improving the noise characteristics, since it is possible that the multi-core cable PLC output units SL-P, SL-PP may not be able to receive the signal correctly, please use output modules which have an output circuit capacitance of 0.01 !F or less. Notes: 3) Since the multi-core cable PLC output units SL-P, SL-PP are high input impedance, time division input type devices, please use PLC output modules whose output circuit can operate at a load current of even 0.1 mA. 1042 Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com ORDER GUIDE PLC related units For input Description For output Manufacturer PLC FP∑ SL-S1 SL-S2 SL-P1 SL-P2 Fujitsu connector specs. MIL connector specs. PLC input connector PLC output connector (Note 2, 3) PLC input connectors PLC output connectors (same shape) SL-S3 SL-P3 PLC I/O connectors ( Max. four PLC I/O connectors can be cascaded with one S-LINK controller. ) PLC Control cable Cascade cable The listed PLC I/O modules (NPN I/O type) allow the mating PLC I/O connector to be plugged on them for signal transmission between the PLC and the S-LINK controller. The PLC I/O connector converts I/O data from End serial to parallel, and connector vice versa. I/O points: 32 points per connector SL-S4 SL-S5 SL-S6 SL-P4 SL-P5 SL-P6 SL-S7 End connector Cascade cable Control cable SL-E SL-F70 SL-F150 SL-F250 SL-F1000 SL-C1000 SL-C2000 SL-C5000 SL-C2000F Matsushita Electric Works, Ltd. the ( Excluding FPG-C32T ) PLC input PLC output module (Note 4) module (Note 4) FPG-XY64D2T FPG-XY64D2T (X side) (Y side) FP2 FP2-X32D2 FP3, FP10S AFP33027 FP10SH TC200 TC64DI Toshiba Machine Co., Ltd. NS-X64-1 NS series NS-XY64-1 (X side) NV1X3204 NV1X3204-W F55 NV1X3206 NC1X3204 NC1X3204-3 Fuji Electric NC1X3206 Co., Ltd. F70 NC1X6404 NC1X6406 NC1W6406T (X side) F80H, F120H FTU125A F120S FTU126A F140S FTU127C FTU612A (X side) F15XS NP1X3206-W Fuji Electric SX series SPH NP1X6406-W Co., Ltd. A1SX41 AnS A1SX42 A1SH42 (X side) Mitsubishi AnN, AnA AX42 Electric Corp. AnU, QnA AH42 (X side) QnAs QX41, QX42 Q AJ35TC1-32D A2CJ JW20 JW20H JW-234N Sharp JW30H JW-264N Manufacturing JW-34NC Systems Corp. JW50H JW-64NC CS1W-ID231 CS1 CS1W-ID261 CS1W-MD261 (X side) CVM1, CV C500 C500-ID219 Omron Corp. C1000H C2000H C200H-ID216 C200H series C200H-ID217 CQM1 CQM1-ID213 EH-XD32 EH-150 Hitachi Ltd. XD64-6N FA500 WD64-6N (X side) Yokogawa Electric Corp. F3XD32-3N FA-M3 F3XD64-3N DI-335 Toshiba Corp. T3 DI-335H GL20, GL40S Yasukawa GL60S, GL60H Electric GL70H Corp. H series XDC24D2H Hitachi Ltd. GL20, GL40S Yasukawa GL60S, GL60H B2605 Electric Corp. GL70H FP2-Y32T AFP33487 TC64DON NS-Y64-T1 NS-XY64-1 (Y side) NV1Y32T05P1 NC1Y32T05P1 NC1Y64T05P1-1 NC1W6406T (Y side) FTU222A FTU227C FTU612A (Y side) NP1Y32T09P1 NP1Y64T09P1 A1SY41 A1SY42 A1SH42 (Y side) AY42 AH42 (Y side) QY41P, QY42P AJ35TC1-32T JW-232S JW-262S JW-32SC JW-62SC CS1W-OD231 CS1W-OD261 CS1W-MD261 (Y side) C500-OD213 C200H-OD218 C200H-OD219 CQM1-OD213 EH-YT32 YD64-1A WD64-6N (Y side) F3YD32-1A F3YD64-1A DO-335 B2604 YTR24DH It must be connected at the end of the last PLC I/O connector. Length: 70 mm 2.756 in Length: 150 mm 5.906 in Length: 250 mm 9.843 in Length: 1,000 mm 39.370 in Length: 1 m 3.281 ft Length: 2 m 6.562 ft Length: 5 m 16.404 ft Length: 2 m 6.562 ft It links two PLC I/O connectors. It links the S-LINK controller and the first PLC I/O connector. Notes: 1) Components with ‘ ’ mark conform to the CE marking EMC Directive. However, note that for the PLC I/O connectors to conform to CE marking EMC Directive, it is necessary to use cascade cable SL-F70, SL-F150 or SL-F250 and control cable SL-C2000F. Notes: 2) The PLC I/O connectors use Fujitsu connectors. However, SL-S1, SL-S6, SL-P1 and SL-P6 connectors use MIL connectors. Notes: 3) PLC I/O connectors are connectable to S-LINK controller SL-CU1A only. Notes: 4) X side and Y side indicate the input and the output connectors, respectively, of the compound input / output module. Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 1043 Wire-saving System S-LINK S-LINK V Appearance (Note 1) Laser Marker LP-200 LP-F10 Model No. Designation SYSTEMS S-LINK SYSTEMS S-LINK ORDER GUIDE S-LINK I/O devices Appearance (Note) Model No. Description SL-CH1 NPN type SL-CH1-PN PNP type SL-CH21 NPN type 1 channel I/O unit 2 channel I/O mixed unit SL-CH21-PN PNP type SL-CH21K NPN type SL-CH20 NPN type Electrically insulates output as well as main circuits. It is suitable for power supply remote control function of NEC FA personal computer FC-9821Xa/Ka. 2 input devices are connectable. 2 channel input unit SL-CH20-PN PNP type SL-CH22 NPN type 2 output devices are connectable. 2 channel output unit Connector I/O unit It can be used as either an input unit or an output unit by switch selection. Hence, a sensor, limit switch, etc., is connectable when it is used as an input, and a relay, lamp, etc., is connectable when it is used as an output. 1 input and 1 output device are connectable. 2 channel isolation I/O unit Analog I/O arrayed terminal unit LP-F10 LP-200 Laser Marker S-LINK V S-LINK Wire-saving System Designation SL-CH22-PN PNP type 8 channel snap-connector input unit SL-T8J 8 NPN inputs SL-T8J-PN 8 PNP inputs 8 channel snap-connector output unit SL-TP8J 8 NPN outputs SL-TP8J-PN 8 PNP outputs 16 channel MIL connector input unit SL-T16C1 16 NPN inputs SL-T16C1-PN 16 PNP inputs 16 channel MIL connector output unit SL-TP16C1 16 NPN outputs SL-TP16C1-PN 16 PNP outputs Input terminal SL-TBAD4 4 inputs This is an analog input terminal unit which can connect 4 devices having an analog output. Since power supply terminals have been provided for each input channel, neat wiring is possible. Output terminal SL-TBDA1 1 output This is an analog output terminal unit which can connect one device requiring an analog input. It is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line. Note: Components with ‘ 1044 8 input or 8 output devices are connectable with snap male connectors. The output unit is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line. Since connection can be made with an MIL connector, 16 input or 16 output devices can be connected to this slim I/O unit. The output unit is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line. ’ mark conform to the CE marking EMC Directive. Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com ORDER GUIDE S-LINK I/O devices Model No. Description SL-TW4 4 NPN inputs SL-TW4-PN 4 PNP inputs SL-TW8 8 NPN inputs SL-TW8-PN 8 PNP inputs Environment resistant I/O unit Input unit SL-TW2P2-PN 2 NPN inputs and These are units which can connect 2 inputs and 2 outputs. 2 NPN outputs They feature IP67 (IEC 60529) protection, which can withstand water splashes. They are incorporated with an output signal hold function, which retains the output state just prior to an error on the 2 PNP inputs and signal transmission line. 2 PNP outputs SL-TWP4 4 NPN outputs SL-TWP4-PN 4 PNP outputs SL-TB4 4 NPN inputs SL-TB4-PN 4 PNP inputs SL-TB8 8 NPN inputs SL-TB8-PN 8 PNP inputs SL-TB16 16 NPN inputs SL-TB16-PN 16 PNP inputs SL-TBP4 4 NPN outputs SL-TBP4-PN 4 PNP outputs SL-TBP8 8 NPN outputs SL-TBP8-PN 8 PNP outputs SL-TBP16 16 NPN outputs SL-TBP16-PN 16 PNP outputs SL-TBP4-TY 4 NPN outputs SL-TBP8-TY 8 NPN outputs SL-TBP16-TY 16 NPN outputs 4 relay output SL-TPR4 4 outputs (Note 2) 8 relay output SL-TPR8 8 outputs (Note 2) SL-TW2P2 I/O mixed unit Output unit I/O arrayed terminal unit Input terminal Output terminal Separate load power supply type Relay output terminal unit These are units which can connect 4 or 8 input devices. They feature IP67 (IEC 60529) protection, which can withstand water splashes. The input devices can be easily connected by using optional composite connectors. These can connect 4 output devices. They feature IP67 (IEC 60529) protection, which can withstand water splashes. They are incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line. They are screw-on terminal units to which 4, 8 or 16 input devices are connectable. Since power supply terminals have been provided for two input channel, neat wiring is possible. They are screw-on terminal units to which 4, 8 or 16 output devices are connectable. The output unit is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line. They enable forced turning OFF of the output device connected to the output terminal without halting the complete S-LINK system, by switching off the load power supply. They are terminal units to which 4 or 8 output devices can be connected by slim socket relays that can be easily replaced. They are incorporated with an output signal hold function which retains the output state just prior to an error on the signal transmission line. Notes: 1) Components with ‘ ’ mark conform to the CE marking EMC Directive. Notes: 2) Relay output is ‘Contact a’ only. Further, when replacing the relay, use PA relay (APA3312) manufactured by Matsushita Electric Works, Ltd. Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 1045 Wire-saving System S-LINK S-LINK V Appearance (Note 1) Laser Marker LP-200 LP-F10 Designation SYSTEMS S-LINK SYSTEMS S-LINK ORDER GUIDE S-LINK I/O devices Snap-connector Appearance (Note 1) Sensor main block For plug-in unit Model No. SL-BMJ Description It allows connection of various kinds of input devices, such as, photoelectric sensors, inductive proximity sensors, limit switches, and push buttons with the snap female connectors. Changes signals from input devices into serial signals and transmits them to the signal transmission line. One SL-BMJ can be extended by one SL-BXJ or two SL-BXs, up to 16 input points. It can generate the ORed self-diagnosis output of all the connected devices. In this case, the first channel gets occupied. ( Extension block Sensor block LP-F10 LP-200 Laser Marker S-LINK V S-LINK Wire-saving System Designation Sensor main block SL-BXJ It can follow either main block, and allows connection of 8 input devices. SL-BM It allows connection of various kinds of plug-in units and changes signals from plug-in units into serial signals and transmits them to the signal transmission line. One SL-BM can be extended by three SL-BXs or one SL-BX plus one SL-BXJ, up to 16 input points. It can generate the ORed self-diagnosis output of all connected units. In this case the first channel gets occupied. ( Extension block SL-BX Digital setting fiber sensor (Note 2) Manually set fiber sensor Amplifierseparated photoelectric sensor Amplifierseparated inductive proximity sensor One touch clamping type Screw tightening type Retroreflective type with polarizing filters S-LINK direct hook-up photoelectric sensor Red LED FX-A1J Red LED FX-A1GJ Green LED FX-M1J Red LED FX-M1GJ Green LED SU-7J Its thickness is merely 10 mm 0.394 in. The sensitivity is automatically set with ease.12 kinds of sensor heads are suitable with it. (For details, refer to p.386l for the SU-7 series.) S-LINK direct hook-up picking sensor Diffuse reflective type Its thickness is merely 10 mm 0.394 in. The sensitivity setting is simple by using the jog switch. Level indicators, comprising of 10 LEDs, which enable confirmation of the set sensitivity at a glance, have been incorporated. (For details, please contact our office.) Its thickness is merely 10 mm 0.394 in. Since the sensitivity setting is done by a 12-turn potentiometer, fine setting is possible. (For details, please contact our office.) GA-15J Its thickness is merely 10 mm 0.394 in. The sensitivity is so precisely set with the 18-turn adjuster that the sensor is suitable for sophisticated applications with a high repeatability of 1 !m 0.039 mil or less. (For details, refer to p.754l for the GA-10 series.) SL-TJ1 It allows connection of 1 No. of various kinds of input devices, such as, a photoelectric sensor, an inductive proximity sensor or a limit switch. SL-A11 Thru-beam type 10 m 32.808 ft SL-A13 Thru-beam type 30 m 98.425 ft SL-A19 Thru-beam type Its thickness is merely 10 mm 0.394 in. The incident light intensity and the threshold value can be seen at a glance from the backlight LCD. Further, threshold value setting is simple by using the jog switch. (For details, please contact our office.) FX-D1J GA-14J Input terminal unit ) It can follow either main block, and allows connection of four plug-in units. Auto-setting fiber sensor Plug-in unit ) SL-A12 Retroreflective type with polarizing filters 0.1 to 5 m 0.328 to 16.404 ft Diffuse reflective type 700 mm 27.559 in Sensing range: 0.2 to 3 m 0.656 to 9.843 ft 0.05 to 1 m 0.164 to 3.281 ft when the switch is set to SHORT Beam pitch: 25 mm 0.984 in Sensing height: 100 mm 3.937 in Sensing object: "35 mm "1.378 in or more opaque object ( SL-N15 These can be hooked up to the S-LINK cable, at any place, without any interface. is a parts-taking verification sensor with five sensing ) Itbeams and can be hooked up to the S-LINK cable without any interface. Both the emitter and the receiver are incorporated with bright orange LED job indicators that are easily visible to the operator. Notes: 1) Components with ‘ ’ mark conform to the CE marking EMC Directive. Notes: 2) Output 2 cannot be used when connection is made to the plug-in unit sensor block. 1046 Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com ORDER GUIDE Connectors Model No. Description SL-J1A 10 pcs. per set It creates a ‘T’-branch connection between two S-LINK exclusive flat cables (4-core). For 0.5 mm2 flat cable to 0.5 mm2 flat cable connection (Gray) Applicable hook-up pliers: SL-JPS, SL-JPD SL-J3A 10 pcs. per set It can extend the S-LINK exclusive flat cable (4-core). For 0.5 mm2 flat cable to 0.5 mm2 flat cable connection (Black) Applicable hook-up pliers: SL-JPS, SL-JPD SL-JE 5 pcs. per set It must be connected at the end of the main cable. For 0.5 mm2 flat cable (Gray) Applicable hook-up pliers: SL-JPS, SL-JPD Cable attached end connector SL-JE-RC When cabtyre cable is used as the main cable, the end connector can be easily connected. Cable end socketbranch hook-up connector SL-JK 10 pcs. per set It enables one I/O device to be connected at the S-LINK exclusive 0.5 mm2 flat cable (4-core) end with the snap male connector (SL-CP).(Light blue) Applicable hook-up pliers: SL-JPS, SL-JPD SL-JK1 10 pcs. per set It enables one I/O device to be branched off in the middle of the S-LINK exclusive 0.5 mm2 flat cable (4-core) with the snap male connector (SL-CP).(Blue) Applicable hook-up pliers: SL-JPS, SL-JPD SL-CJ1 (White) 10 pcs. per set For 0.08 to 0.2 mm2 (Conductor cross-section area) This snap female connector is used for Wire dia.: "0.7 to "1.2 mm "0.028 to "0.047 in plugging into the socket of SL-BMJ or SL-BXJ to connect an input device, or into the snap male connector SL-CP1 2 For 0.3 mm (Conductor cross-section area) or SL-CP2 Wire dia.: "1.1 to "1.6 mm "0.043 to " 0.063 in Applicable hook-up pliers: SL-JPC Hook-up connector (Note) Cable extension hook-up connector (Note) End hook-up connector (Note) (Note) ‘T’-branch hook-up connector 4-pin type snap female connector 1 3 2 4 (Note) SL-CJ2 (Black) 10 pcs. per set SL-CP1 (White) 10 pcs. per set 1 4-pin type snap male connector 2 3 4 (Note) (Note) Environment resistant I/O unit Composite male connector SL-CP2 (Black) 10 pcs. per set SL-CP3 (Greenish blue) 10 pcs. per set For 0.08 to 0.2 mm2 (Conductor cross-section area) Wire dia.: "0.7 to "1.2 mm "0.028 to "0.047 in This snap male connector is used for connecting S-LINK I/O devices to SL-T8J(-PN) and SL-TP8J(-PN) 8-chanFor 0.3 mm2 (Conductor cross-section area) nel snap-connector I/O units as well as to Wire dia.: "1.1 to "1.6 mm "0.043 to " 0.063 in SL-JK and SL-JK1 hook-up connectors. Applicable hook-up pliers: SL-JPC (for the SL-CP1 and SL-CP2) For 0.5 mm2 (Conductor cross-section area) SL-JPE (for the SL-CP3) Wire dia.: "1.7 to "2.5 mm "0.067 to "0.098 in SL-WP4 10 pcs. per set For 0.18 to 0.75 mm2 (Conductor cross-section area) Wire dia.: "3 to "4 mm "0.118 to "0.157 in SL-WP5 10 pcs. per set These are composite male connectors For 0.18 to 0.75 mm2 (Conductor cross-section area) for connection of input or output devices Wire dia.: "4 to "5 mm "0.157 to "0.197 in to the environment resistant I/O unit SL-TW(-PN), and for connection to For 0.18 to 0.75 mm2 (Conductor cross-section area) the branch connector Wire dia.: "5 to "6 mm "0.197 to "0.236 in SL-WY or the composite female connector SL-WJ8. SL-WP6 10 pcs. per set SL-WP8 10 pcs. per set For 0.3 to 0.75 mm2 (Conductor cross-section area) Wire dia.: "6 to "8 mm "0.236 to "0.315 in Composite female connector SL-WJ8 10 pcs. per set These are composite female connectors for connection to the main cable side of For 0.3 to 0.75 (Conductor cross-section area) the environment resistant I/O unit Wire dia.: "6 to "8 mm "0.236 to "0.315 in SL-TW(-PN), and for connection to the branch connector SL-WY or the composite male connector SL-WP. Branch connector SL-WY 5 pcs. per set This is a connector for branching of the main / branch cable and for connection of the thru-beam type photoelectric sensor to the environment resistant I/O unit SL-TW(-PN). Environment resistant end connector SL-WE It is connected when the environment resistant I/O unit SL-TW(-PN) is used at the end of the main cable. Cover for M12 male connector SL-WPK 10 pcs. per set Make sure to put it on the unused main cable side connectors of the environment resistant I/O unit SL-TW(-PN). Cover for M12 female connector SL-WJK 10 pcs. per set Make sure to put it on the unused I/O side connectors of the environment resistant I/O unit SL-TW(-PN). mm2 Note: For UL compatibility, please contact our office. Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 1047 Wire-saving System S-LINK S-LINK V Appearance Laser Marker LP-200 LP-F10 Designation SYSTEMS S-LINK SYSTEMS S-LINK ORDER GUIDE Basic units S-LINK V S-LINK Wire-saving System Designation Appearance Model No. Description SL-M8 8 inputs SL-M16 16 inputs SL-M4P4 4 inputs and 4 outputs SL-MP8 8 outputs SL-MP16 16 outputs SL-M8F 8 inputs SL-M16F 16 inputs SL-M4P4F 4 inputs and 4 outputs SL-MP8F 8 outputs SL-MP16F 16 outputs Vertical type Input module I/O mixed module I/O module These are IC type modules which enable external connection of address setting switches and operation indicators. They increase the design flexibility. Input module Horizontal type LP-F10 LP-200 Laser Marker Output module I/O mixed module Output module Optional units Designation Appearance (Note) Booster Handy monitor Note: Components with ‘ 1048 Model No. Description SL-BS1A It can extend the signal transmission distance by 200 m 656.168 ft. A maximum of seven boosters can be connected for one S-LINK control unit. However, one booster can never be followed by another booster in series. SL-HM1 It can be connected at any place on the signal transmission line and the I/O states can be checked in batches of 16. The handy monitor is also incorporated with the S-LINK control functions, so that, for example, it can perform an I/O check on conveyor system segments, still under assembly, even without the S-LINK controller. ’ mark conform to the CE marking EMC Directive. Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com OPTIONS Others 8-branch connector tap Model No. SL-T8PW SL-CJ12 (White) 10 pcs. per set 2-pin type snap female connector (Note) SL-CJ22 (Black) 10 pcs. per set SL-CP12 (White) 10 pcs. per set 2-pin type snap male connector (Note) SL-CP22 (Black) 10 pcs. per set Description Connects easily to up to 8 thru-beam type photoelectric sensor emitters or S-LINK I/O devices with snap male connectors. For 0.08 to 0.2 mm2 (Conductor cross-section area) It can be used for cable extension of Wire dia.: "0.7 to "1.2 mm "0.028 to "0.047 in 2-wire I/O devices by combining with a For 0.3 mm2 (Conductor cross-section area) snap male connector SL-CP12 or Wire dia.: "1.1 to "1.6 mm "0.043 to " 0.063 in SL-CP22. For 0.08 to 0.2 mm2 (Conductor cross-section area) Wire dia.: "0.7 to "1.2 mm "0.028 to "0.047 in It can used for cable extension of 2-wire I/O devices by combining with a snap For 0.3 mm2 (Conductor cross-section area) female connector SL-CJ12 or SL-CJ22. Wire dia.: "1.1 to "1.6 mm "0.043 to " 0.063 in SL-RCM100 D line: White SL-RCM100-PK Exclusive flat cable (4-core) SL-RCM100-GN SL-RCM100-GY Length: 100 m 328.084 ft D line: White with pink stripe D line: White with green stripe D line: White with gray stripe S-LINK / S-LINK V exclusive flat cable (4-core) Conductor cross-section area: 0.5 mm2 Outer diameter: "2.5 mm "0.098 in4 SL-RCM200 Length: 200 m 656.168 ft, D line: White SL-CBM100 Length: 100 m 328.084ft SL-CBM200 Length: 200 m 656.168 ft Exclusive pliers SL-JPS Hook-up connector (SL-J) can be connected in one grip. Exclusive ratchet pliers SL-JPD Because of the ratchet mechanism, hook-up connector (SL-J) can be simply connected in one grip. SL-CP3 exclusive pliers SL-JPE 4-pin type snap male connector (SL-CP3) can be connected in one grip. Male / female connector exclusive pliers SL-JPC Snap female connector (SL-CJ) and snap male connector (SL-CP1/CP2 and SL-CP11/CP12) can be connected in one grip. Address label SL-MA1-SET 4 sheets per set By sticking the labels on the respective S-LINK devices, the set addresses can be confirmed at one glance. SL-MA1-SET is available in white, pink, green and gray colors, as a 4-sheet set, and is convenient when used by matching the color with that of the S-LINK exclusive flat cable (100 m 328.084 ft type). Marking plate SL-MA2 20 pcs. per set It is used to write the I/O device No., address No., etc., on the environment resistant I/O unit SL-TW(-PN). DIN rail mounting bracket for the SL-CH MS-CH10 10 pcs. per set Mounting bracket enabling the SL-CH(-PN) I/O units to be mounted onto a 35 mm 1.378 in width DIN rail. They can also be affixed with screws. (When affixing with screws, arrange two M4 pan-head screws separately.) I/O unit holder for SL-CH MS-SLH 5 pcs. per set It is used to mount the SL-CH(-PN) unit. (Please arrange two M4 pan-head screws separately.) (Note) Exclusive cabtyre cable (4-core) S-LINK / S-LINK V exclusive cabtyre cable (4-core) Conductor cross-section area: 0.5 mm2 Outer diameter: "7.4 mm "0.291 in (Hook-up connector cannot be used) Note: For UL compatibility, please contact our office. Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 1049 Wire-saving System S-LINK S-LINK V Appearance Laser Marker LP-200 LP-F10 Designation SYSTEMS S-LINK SYSTEMS S-LINK ORDER GUIDE Accessories • NPS-CV Protective cover for the SL-CU1A, SL-BS1A or SL-CU1-485 S-LINK V S-LINK Wire-saving System ( • RF-230 • (Reflector for the SL-A19) ) • MS-SL-2 • (Mounting base for connector I/O units) OPTION Sensor mounting bracket for SL-A LP-F10 LP-200 Laser Marker Designation Sensor mounting bracket for SL-A Sensor mounting bracket for SL-N15 Model No. MS-NX5-1 Foot angled mounting bracket (The thru-beam type sensor needs two brackets.) MS-NX5-2 Foot biangled mounting bracket (sensor protection bracket) (The thru-beam type sensor needs two brackets.) MS-NX5-3 Back angled mounting bracket (The thru-beam type sensor needs two brackets.) MS-NA1-1 MS-NA2-1 • MS-NX5-2 • MS-NX5-3 Two M4 (length 25 mm 0.984 in) screws with washers and two M4 nuts are attached. Two M4 (length 25 mm 0.984 in) screws with washers and two M4 nuts are attached. Two M4 (length 25 mm 0.984 in) screws with washers and two M4 nuts are attached. Sensor mounting bracket for SL-N15 • MS-NA1-1 • MS-NA2-1 It protects the sensor body. Two bracket set (Silver) Four M4 (length 15 mm 0.591 in) screws with washers, and four nuts are attached. MS-NA3-BK It protects the sensor body. Two bracket set (Black) Four M4 (length 15 mm 0.591 in) screws with washers, and four nuts are attached. M4 screws with washers, nuts and hooks are attached. M4 screws with washers, nuts, hooks and spacers are attached. Reflector mounting bracket for RF-230 Sensor protection bracket for SL-N15 Reflector mounting bracket Reflector mountMS-RF23 ing bracket OS-NA1-5 10 sheets per set Connector I/O unit mounting bracket, MS-DIN-3 8-branch connector tap mounting bracket DIN rail adaptor Four bracket set Four M4 (length 15 mm 0.591 in) screws with washers, eight nuts, four hooks, four spacers and eight M4 (length 18 mm 0.709 in) screws with washers are attached. (Spacers are not attached with MS-NA1-1.) • MS-NX5-1 MS-NA3 Sensor protection bracket for SL-N15 Slit mask for SL-N15 Description The seal type slit mask restrains the amount of beam emitted or received. Take care that the sensing range will be reduced when the slit mask is used. ( ) • MS-NA3 • MS-NA3-BK It is a DIN rail mounting bracket which can be fitted on the mounting base of SL-T8J, SL-TP8J, SL-T16C1, SL-TP16C1 and SL-T8PW. This adaptor is used when mounting the MS-DIN-IDC SL-GU1- to the 35 mm 1.378 in DIN rail. Two M4 (length 10 mm 0.394 in) screws with washers are attached. M4 screws with washers and nuts are attached. Slit mask for SL-N15 • OS-NA1-5 DIN rail adaptor • MS-RF23 Connector I/O unit mounting bracket, 8-branch connector tap mounting bracket • MS-DIN-3 • MS-DIN-IDC Two M4 (length 12 mm 0.472 in) screws with washers Two pcs. are attached with the DIN rail adaptor ( ) DIN rail adaptor MS-DIN-IDC 7 6 5 4 3 2 1 0 35 mm 1.378 in width DIN rail Stopper SL-GU1- (located on the back) 1050 Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com • This product does not possess control functions needed for accident prevention or safety maintenance. Handle safety related or emergency stop signals without passing them through the S-LINK system due to fail-safe considerations. • Before touching this product, remove any electrostatic charge that may be present on your body. There is a danger of this product getting damaged due to the electrostatic charge. The sensor & wire-saving link system are not mutually interchangeable with the flexible wire-saving system and cannot be mixed and matched. Please exercise caution. Nevertheless, any of the exclusive 4-core flat cable, connectors, hook-up pliers, or SL-T8PW 8-branch connector taps can be used. Refer directly to our partner makers for more details pertaining to the S-LINK compatible devices introduced here. Laser Marker LP-200 LP-F10 Information about S-LINK partner makers [Controllers suitable for S-LINK] Matsushita Electric Works, Ltd. SYSTEMS PRECAUTIONS FOR PROPER USE Wire-saving System S-LINK S-LINK V S-LINK Mitsubishi Electric Corp. Toyoda Machine Works Co., Ltd. Limit switches Ultrasonic sensors Matsushita Electric Works, Ltd. Matsushita Electric Works, Ltd. Component indicator lamp Yazaki Industrial Chemical Co., Ltd. Manifold electromagnetic valves Koganei Corp. Manifold electromagnetic valves SMC Pneumatics [S-LINK direct hook-up I/O devices] Manifold electromagnetic valves CKD Corp. Information about the ‘Design Manual’ and ‘Construction Manual’ for the S-LINK sensor & wire-saving link system We have two manuals available with more detailed information pertaining to the S-LINK sensor & wire-saving link system. Please contact our office for details. S-LINK Design Manual Holds information necessary when designing the layout for the S-LINK system. Refer to it for specifications and for illustration showing exterior dimensions. S-LINK Construction Manual Holds information necessary when introducing, constructing, and activating the S-LINK system. Refer to it for construction or startup cautionary items. Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com 1051
MS-SL-2 价格&库存

很抱歉,暂时无法提供与“MS-SL-2”相匹配的价格&库存,您可以联系我们找货

免费人工找货