6PDT FLATPACK 2AMP
DIL RELAY
NL-RELAYS
FEATURES
32.4
1.276
• Space saving dimensions — 25.4 mm × 32.4 mm × 10.9 mm
1.000 inch× 1.276 inch× 0.429 inch
• Latching types available
• Low operating power — 400 mW (single side stable)
Transistor compatible
• High breakdown voltage for transient protection — 1,000 Vrms between open
contacts, contact sets, and 1,500 V FCC surge between open contacts
• Soldering flux inflow completely prevented
25.4
1.000
10.9
.429
NLE Amber Relays
mm inch
SPECIFICATIONS
Contacts
Characteristics
Arrangement**1
Contact material
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Rating
(resistive)
Expected
life (min.
operations)
5×105
106
Minimum set and reset power
Nominal set and reset power
Max. 15 ms (Approx. 10 ms)
Max. 10 ms (Approx. 5 ms)
Ambient
temp.
Max. 65°C
with nominal coil voltage
and at switching current 2 A
Min. 147 m/s2 {15 G}
Min. 980 m/s2 {100 G}
58.8 m/s2 {6 G}, 10 to 55 Hz
at double amplitude of 1 mm
117.6 m/ s2 {12 G}, 10 to 55 Hz
at double amplitude of 2 mm
–40°C to +55°C
–40°F to +131°F
Humidity
5 to 85% R.H.
Temperature rise
Functional*4
Destructive*5
Shock resistance
Coil (polarized) (at 25°C 77°F)
Nominal operating power
2,000 Vrms
Release time (without diode)*3
(at nominal voltage)
**1 MBB contact types also available: 2 MBB, 4 MBB & 6 MBB
**2 Gold capped silver-palladium contact also available
Minimum operating power
1,000 Vrms
Breakdown
voltage*2
2 A 30 V DC
60 VA, 60 W
125 V AC, 30 V DC
2A
5×107
2 A 30 V DC
0.6 A 100 V DC
50 cps
Min. 100 MΩ at 500 V DC
Between open contacts,
contact sets
Between contacts and
coil
Operate time*3 (at nominal voltage)
100 mΩ
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Mechanical
Electrical
(resistive)
Maximum operating speed
Initial insulation resistance*1
6 Form C
gold-clad silver**2
Functional*6
Approx. 460 mW
up to 60 V DC: Approx. 720 mW
110 V DC: Approx. 900 mW
Approx. 1,000 mW
Approx. 1,600 mW
Vibration resistance
Destructive
Conditions for operation,
transport and storage*7
(Not freezing and condensing at low temperature)
Unit weight
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section
*2 Detection current: 10 mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
*7 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Approx. 17 g.60 oz
TYPICAL APPLICATIONS
Telecommunications, security equipment, detection systems.
ORDERING INFORMATION
Ex.
Contact arrangement
6: 6 Form C
Classification of type
NL
6
EB
X
6M
MBB function
EB: Amber sealed type Nil: 6 Form C
L2
DC48V
1
Operating function
Coil voltage
Contact material
Nil: Single side
Nil: stable
L2: 2 coil latching
DC: 5, 6, 12, 24,
48, 60, 110 V
Nil: Gold-clad silver
1: Gold-cap over
1: silver palladium
(Notes) 1. For UL/CSA or VDE recognized types, add suffix UL/CSA or VDE.
(Notes) 2. Standard packing Carton: 20 pcs. Case: 200 pcs.
201
NL
TYPES AND COIL DATA (at 20°C 68°F)
Single side stable
2 coil latching
Coil voltage, V DC
Part No.
Pick-up
(max.)
NL6EBX-DC5V
NL6EBX-DC6V
NL6EBX-DC12V
NL6EBX-DC24V
NL6EBX-DC48V
NL6EBX-DC60V
NL6EBX-DC110V
4.0
4.8
9.6
19.2
38.4
48
88
Coil voltage,* V DC
Nominal
Coil
operating
resistance,
Drop-out Maximum
power,
(min.)
allowable Ω (±10%)
mW
0.5
6.0
34.7
0.6
7.2
50
1.2
14.4
200
720
2.4
28.8
800
4.8
57.6
3,200
6.0
72
5,000
11.0
132
13,467
898
Part No.
NL6EBX-L2-DC5V
NL6EBX-L2-DC6V
NL6EBX-L2-DC12V
NL6EBX-L2-DC24V
NL6EBX-L2-DC48V
NL6EBX-L2-DC60V
NL6EBX-L2-DC110V
Set
(max.)
Reset
(max.)
4.0
4.8
9.6
19.2
38.4
48
88
4.0
4.8
9.6
19.2
38.4
48
88
Nominal
Coil
operating
resistance,
Maximum
power,
allowable Ω (±10%)
mW
5.5
15.6
6.6
22.5
13.2
90
1,600**
26.4
360
52.8
1,440
66
2,250
121
7,563
* See NOTE 2
** Two coil latching series are for intermittent operation only.
Power should be applied to coil continuously for no more than two minutes.
DIMENSIONS
mm inch
Single side stable
2 coil latching
PC board pattern
(Bottom view)
2.54
2.54
.100 5.08 .100
.200
2.54
.100
11 12 13 14 15 16
25.4
1.000
2.54
.100
11 12 13 14 15 16
2.54×11
.100×11
10 9 8
3.5
.138
10.9
.429
2.54
.100
17 18 19 20 21 22
27.94
1.100
32.4 1.276
6
PC board pattern
(Bottom view)
2.54
2.54
.100 5.08 .100
.200
5
25.4
1.000
10 9 8 7 6
10.9
.429
2
3
5
6
8
5 4 3 2 1
22-1.2 DIA HOLES
22-.047 DIA HOLES
Schematic (Top view)
16 15 14 13 12 11
5.08
2.54 .200 2.54
.100
.100
2.54 5.08 2.54
.100 .200 .100
1
3.5
.138
32.4 1.276
Schematic (Top view)
22 21 20 19 18 17
2.54×11
.100×11
27.94
1.100
3 2 1
20-1.2 DIA HOLES
20-.047 DIA HOLES
2.54
.100
17 18 19 20 21 22
9 10
22 21 20 19 18 17
1
2
3
4
5
16 15 14 13 12 11
6
7
8
9 10
General tolerance: ±0.3 ±.012
REFERENCE DATA
1. Electrical life (2 A 30 V DC resistive load)
2. Coil temperature rise
Pick-up voltage
Max.
Min.
15
10
Drop-out voltage
Max.
Min.
5
0
50
100
No. of operations, ×104
70
N.C. contact
N.O. contact
70
Max.
Max.
60
50
40
Min.
30
20
Temperature rise, °C
20
Contact resistance, mΩ
Pick-up/drop-out voltage, V
25
60
2 A carrying
50
No load
40
30
10
0
50
100
No. of operations, ×104
0
100
110
Coil applied voltage,%V
NOTES
On two coil latching relays
1. To maintain insulation between coils,
terminals 6 and 7 should be connected to
provide common return.
6
Latch coil
5
Latch switch
7
2. Two coil latching relays are for intermittent operation only. Power should be applied to coils for no more than two
minutes; continuous operation may burn
out the coils.
3. Position of MBB contacts
2M (2 Form D 4 Form C):
1-21-22, 10-11-12
4M (4 Form D 2 Form C):
1-21-22, 2-20-18, 9-13-15, 10-11-12
Reset coil
4
Reset switch
For Cautions for Use, see Relay Technical Information
202
9/1/2000
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.