0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PM-R65-P

PM-R65-P

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SENSOR SLOT PNP

  • 数据手册
  • 价格&库存
PM-R65-P 数据手册
395 FIBER SENSORS U-shaped Micro Photoelectric Sensor Amplifier Built-in PM-25 SERIES PM-45 SERIES PM-65 SERIES Related Information ■■General terms and conditions.............. F-3 ■■Glossary of terms / General precautions.......P.1549~ / P.1552~ ■■Selection guide.............................. P.393~ ■■Korea’s S-mark............................... P.1602 LASER SENSORS PHOTOELECTRIC SENSORS Recognition MICRO PHOTOELECTRIC SENSORS AREA SENSORS Certified (Some models only) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS panasonic.net/id/pidsx/global STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide U-shaped Convergent Reflective PM-25/PM-45/ PM-65 PNP output type available One step ahead in performance and mounting ease Three protection circuits standard on all models PM-25/45/65 SERIES All models are standardly equipped with the following protection circuits in their compact bodies. These protection circuits minimize the possibility of sensor malfunctions caused by erroneous wiring. 1 Reverse supply polarity protection circuit 2 Reverse output polarity protection circuit 3 Output short-circuit protection circuit Ample beam emitting / receiving distance of PM-25/45/65 SERIES 6 mm 0.236 in The beam emitting and receiving sections are 0.5 mm 0.02 in thinner than those on our conventional models while their external dimensions are the same. As a result, the distance between the beam emitting point and receiving point increased by 1 mm 0.039 in. The wider distance means less possibility of collision between the sensing section and sensing object. 13.4 0.528 6 0.236 3.7 0.146 Industry’s first*! IP64 rating PM-25/45 SERIES *As of April 2017, in-company survey. Our original integrated molding method has eliminated grooves and gaps on the sensing surface and main body, thus reducing the possibility of malfunctions caused by splashing water or dust. No ridges on sensing surface No joint seam Beam marks for easy adjustment PM-25/45/65 SERIES The upper-limit and lower-limit positions of beam can be visually confirmed from the front, back, right and left sides of the sensor unit. This allows easy adjustment of the position of sensing object. Upper-limit position of beam axis Lower-limit position of beam axis (Unit: mm in) < Front / back > Beam width Beam width marks are provided on PM25 series and PM45 series. < Right / left > U-shaped Micro Photoelectric Sensor PM-25 SERIES PM-45 SERIES PM-65 SERIES APPLICATIONS FIBER SENSORS Positioning of a pallet Sensing the starting point and overrun of a moving body Overrun sensing Sensing the starting point on a rotating body Starting point Dog Starting point sensing Overrun sensing Pallet is stopped by sensing the dog*. The starting point can be sensed by making a slit in the rotating body. The large operation indicator (orange) lights up when the beam enters. The indicator is easy to see from above and from the sides. PM-45 SERIES Compact size All new models require significantly less mounting space than our conventional models when mounted with the same pitch. What’s more, the new models can directly replace our conventional models currently in use. PM-L45 INDUCTIVE PROXIMITY SENSORS 10 0.394 26 1.024 18.5 0.728 (Unit: mm in) All models easy to mount with M3 screws PM-25/45/65 SERIES The sensor unit can be installed with one or two M3 screws. * M3 screws and washers are not included. ■ Models requiring one M3 screw for installation PM-F25, PM-R25, PM-F65, PM-R65 ■ Models requiring two M3 screws for installation Models other than above Resistant to vibrations and impacts PM-25/45/65 SERIES The sections where stress concentrates, such as the connecting section of the cable and internal circuit, are covered with a resin. This helps prevent malfunctions caused by vibrations and impacts. Resin-filled structure (cross-sectional view) PARTICULAR USE SENSORS VARIATION SENSOR OPTIONS Sensors come in various shapes to suit a wide range of mounting conditions SIMPLE WIRE-SAVING UNITS PM-25 SERIES Ultra-small / Cable type Easy mounting with M2/M3 screws! NPN output 1 m 3.281 ft cable 3 m 9.843 ft cable PNP output 1 m 3.281 ft cable 3 m 9.843 ft cable 1 m 3.281 ft bendingresistant cable 1 m 3.281 ft bendingresistant cable PM-45 SERIES Compact size! 15.5 0.610 14.6 0.575 MICRO PHOTOELECTRIC SENSORS PRESSURE / FLOW SENSORS Compact / Cable type Conventional model (L type) PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Starting point and overrun is sensed using the dog* on the base. Large and easy to see Multi-angle operation indicator PM-25/45/65 SERIES LASER SENSORS AREA SENSORS *“Dog” refers to the sensing object for activating the sensor’s detecting operation. 26 1.024 396 NPN output 1 m 3.281 ft cable 3 m 9.843 ft cable 1 m 3.281 ft bendingresistant cable PNP output 1 m 3.281 ft cable 3 m 9.843 ft cable 1 m 3.281 ft bendingresistant cable Compact / Connector built-in type PM-65 SERIES Easy connection with a single touch using commerciallyavailable connectors NPN output Connector attached cable 1 m 3.281 ft, 2 m 6.562 ft, 3 m 9.843 ft, 5 m 16.404 ft Connector attached bending-resistant cable 1 m 3.281 ft, 2 m 6.562 ft, 3 m 9.843 ft, 5 m 16.404 ft PNP output Connector attached cable 1 m 3.281 ft, 2 m 6.562 ft, 3 m 9.843 ft, 5 m 16.404 ft Connector attached bending-resistant cable 1 m 3.281 ft, 2 m 6.562 ft, 3 m 9.843 ft, 5 m 16.404 ft WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide U-shaped Convergent Reflective PM-25/PM-45/ PM-65 397 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS U-shaped Micro Photoelectric Sensor PM-25 SERIES PM-45 SERIES PM-65 SERIES Ultra-small / Cable type  PM-25 SERIES Easy mounting with M2/M3 screws! Cable type NPN output 1 m 3.281 ft cable 3 m 9.843 ft cable Built-in connector PNP output 1 m 3.281 ft cable 3 m 9.843 ft cable * 1 m 3.281 ft bendingresistant cable 1 m 3.281 ft bendingresistant cable Recognition Certified * NPN output / 1 m 3.281 ft cable length type only (Excluding bending-resistant cable type) AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PM-K25 PRESSURE / FLOW SENSORS PM-U25 PM-F25 PM-R25 ORDER GUIDE INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS PM-L25 Type Appearance (mm in) Sensing range SENSOR OPTIONS K type SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS 6 0.236 12.3 0.484 23.9 0.941 Model No. Cable length PM-K25 1 m 3.281 ft PM-K25-R 1 m 3.281 ft, bending-resistant cable PM-K25-C3 3 m 9.843 ft MEASUREMENT SENSORS PM-K25-P 1 m 3.281 ft STATIC CONTROL DEVICES PM-L25 1 m 3.281 ft PM-L25-R 1 m 3.281 ft, bending-resistant cable PM-L25-C3 3 m 9.843 ft PM-L25-P 1 m 3.281 ft PM-U25 1 m 3.281 ft PM-U25-R 1 m 3.281 ft, bending-resistant cable PM-U25-C3 3 m 9.843 ft PM-U25-P 1 m 3.281 ft PM-F25 1 m 3.281 ft PM-F25-R 1 m 3.281 ft, bending-resistant cable PM-F25-C3 3 m 9.843 ft PM-F25-P 1 m 3.281 ft PM-R25 1 m 3.281 ft PM-R25-R 1 m 3.281 ft, bending-resistant cable PM-R25-C3 3 m 9.843 ft PM-R25-P 1 m 3.281 ft L type LASER MARKERS PLC 12 0.472 12 0.472 13.4 0.528 MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide U type FA COMPONENTS F type ENERGY MANAGEMENT SOLUTIONS Ultra-small / Cable type HUMAN MACHINE INTERFACES 6 0.236 16 0.630 13.4 0.528 11.7 0.461 12.5 0.492 13.4 0.528 U-shaped PM-25/PM-45/ PM-65 R type Convergent Reflective 11.7 0.461 13.4 0.528 12.5 0.492 6 mm 0.236 in (fixed) Output Output operation NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor Incorporated with 2 outputs: Light-ON/Dark-ON PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor Note: The suffix “-R” in the model No. indicates a bending-resistant cable type. The suffix “-C3” indicates a 3 m 9.843 ft cable length type. OPTIONS Designation Model No. Description Mounting screw MS-M2 Mounting screw with washers for the ultra-small type sensor (50 pcs. lot). It can mount securely as it is spring washer attached. Mounting screw • MS-M2 M2 (length 10 mm 0.394 in) screw with a spring washer U-shaped Micro Photoelectric Sensor PM-25 SERIES PM-45 SERIES PM-65 SERIES 398 FIBER SENSORS SPECIFICATIONS LASER SENSORS Model No. Type Item NPN output PM-□25 PNP output PM-□25-P Bending-resistant cable 3 m 9.843 ft cable PM-□25-R PM-□25-C3 ― ― Sensing range 6 mm 0.236 in (fixed) Minimum sensing object INDUCTIVE PROXIMITY SENSORS 0.05 mm 0.002 in or less Repeatability 0.01 mm 0.0004 in or less Supply voltage PARTICULAR USE SENSORS 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less SENSOR OPTIONS PNP open-collector transistor NPN open-collector transistor •• Maximum source current: 50 mA •• Maximum sink current: 50 mA •• Applied voltage: 30 V DC or less (between output and +V) •• Applied voltage: 30 V DC or less (between output and 0 V) •• Residual voltage: 2 V or less (at 50 mA source current) •• Residual voltage: 2 V or less (at 50 mA sink current) 1 V or less (at 16 mA source current) 1 V or less (at 16 mA sink current) Output Output operation Incorporated with 2 outputs: Light-ON/Dark-ON Short-circuit protection Under light received condition: 20 μs or less Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz) (Note 2) Operation indicator HUMAN MACHINE INTERFACES IP64 (IEC) Ambient temperature (Note 3, 4) –25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +80 °C –22 to +176 °F Ambient humidity Fluorescent light: 1,000 ℓx or less at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each Shock resistance Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) Material Enclosure: PBT, Display section: Polycarbonate 0.09 mm2 4-core cabtyre cable, PVC, 1 m 3.281 ft long Cable 0.1 mm2 4-core bending-resistant cabtyre cable, PVC, 1 m 3.281 ft long (Note 5, 6) 0.09 mm2 4-core cabtyre cable, PVC, 3 m 9.843 ft long Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 7) Cable extension Weight Net weight: 10 g approx., Gross weight: 15 g approx. Net weight: 30 g approx., Gross weight: 35 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) The response frequency is the value when the disc, given in the figure below, is rotated. Disc 1.8 mm 0.071 in Disc t = 0.2 mm 0.008 in 1.6 mm 0.063 in MACHINE VISION SYSTEMS UV CURING SYSTEMS 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each Emitting element ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS 5 to 85 % RH, Storage: 5 to 95 % RH Ambient illuminance MEASUREMENT SENSORS PLC 3 Protection WIRE-SAVING SYSTEMS LASER MARKERS Orange LED (lights up under light received condition) Pollution degree SIMPLE WIRE-SAVING UNITS STATIC CONTROL DEVICES Incorporated Response time AREA SENSORS PRESSURE / FLOW SENSORS 0.8 × 1.2 mm 0.031 × 0.047 in opaque object Hysteresis MICRO PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS EMC Directive, RoHS Directive CE marking directive compliance Environmental resistance PHOTOELECTRIC SENSORS Ultra-small / Cable type 1.6 mm 0.063 in 3) In case the PM-25 series is used at an ambient temperature of +50 °C +122 °F, or more, make sure to mount it on a metal body. 4) Note that the cable of PM-□25-R loses its flexibility when the ambient temperature decreases to about -10 °C +14 F°. 5) The cable of PM-□25-R is a bending-resistant cable usable on a moving base. When the sensor is mounted on a moving base, secure the sensor cable joint at the unit in place so that stress is not applied to it. 6) When storing PM-□25-R, make sure that the cable does not come into contact with the sensing section or operation indicator. 7) If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. Selection Guide U-shaped Convergent Reflective PM-25/PM-45/ PM-65 399 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS U-shaped Micro Photoelectric Sensor PM-25 SERIES PM-45 SERIES PM-65 SERIES Compact / Cable type  PM-45 SERIES Compact size! Cable type NPN output 1 m 3.281 ft cable 3 m 9.843 ft cable 1 m 3.281 ft bendingresistant cable Built-in connector PNP output 1 m 3.281 ft cable 3 m 9.843 ft cable 1 m 3.281 ft bendingresistant cable * Recognition Certified * NPN output / 1 m 3.281 ft cable length type only AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PM-K45 PRESSURE / FLOW SENSORS PM-L45 PM-Y45 Type Appearance (mm in) Sensing range SENSOR OPTIONS K type SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS 7 0.276 25.4 1.000 21.3 0.839 MEASUREMENT SENSORS T type STATIC CONTROL DEVICES LASER MARKERS 13.7 0.539 26 1.024 PLC 18.1 0.713 UV CURING SYSTEMS Selection Guide U-shaped Convergent Reflective L type 14.6 0.575 26 1.024 7 0.276 6 mm 0.236 in (fixed) 14.6 0.575 Y type MACHINE VISION SYSTEMS F type FA COMPONENTS Compact / Cable type HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS PM-F45 PM-R45 ORDER GUIDE INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS PM-T45 13.4 0.528 20.6 0.811 13 0.512 13.7 0.539 21.3 0.839 R type PM-25/PM-45/ PM-65 13 0.512 13.7 0.539 21.3 0.839 Model No. Cable length PM-K45 1 m 3.281 ft PM-K45-C3 3 m 9.843 ft PM-K45-P 1 m 3.281 ft PM-K45-P-C3 3 m 9.843 ft PM-T45 1 m 3.281 ft PM-T45-C3 3 m 9.843 ft PM-T45-P 1 m 3.281 ft PM-T45-P-C3 3 m 9.843 ft PM-L45 1 m 3.281 ft PM-L45-C3 3 m 9.843 ft PM-L45-P 1 m 3.281 ft PM-L45-P-C3 3 m 9.843 ft PM-Y45 1 m 3.281 ft PM-Y45-C3 3 m 9.843 ft PM-Y45-P 1 m 3.281 ft PM-Y45-P-C3 3 m 9.843 ft PM-F45 1 m 3.281 ft PM-F45-C3 3 m 9.843 ft PM-F45-P 1 m 3.281 ft PM-F45-P-C3 3 m 9.843 ft PM-R45 1 m 3.281 ft PM-R45-C3 3 m 9.843 ft PM-R45-P 1 m 3.281 ft PM-R45-P-C3 3 m 9.843 ft Note: The suffix “-C3” in the model No. indicates a 3 m 9.843 ft cable length type. Output Output operation NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor Incorporated with 2 outputs: Light-ON/Dark-ON U-shaped Micro Photoelectric Sensor PM-25 SERIES PM-45 SERIES PM-65 SERIES 400 FIBER SENSORS SPECIFICATIONS LASER SENSORS Model No. Type Item 3 m 9.843 ft cable NPN output PM-□45 PM-□45-C3 PNP output PM-□45-P PM-□45-P-C3 EMC Directive, RoHS Directive CE marking directive compliance Sensing range 6 mm 0.236 in (fixed) Minimum sensing object 0.8 × 1.2 mm 0.031 × 0.047 in opaque object Hysteresis 0.01 mm 0.0004 in or less Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less Output operation Incorporated with 2 outputs: Light-ON/Dark-ON Short-circuit protection Incorporated Under light received condition: 20 μs or less Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz) (Note 2) Response time Operation indicator Orange LED (lights up under light received condition) Pollution degree 3 Protection –25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +80 °C –22 to +176 °F Ambient humidity 5 to 85 % RH, Storage: 5 to 95 % RH Ambient illuminance Fluorescent light: 1,000 ℓx or less at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each Shock resistance PRESSURE / FLOW SENSORS PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each Emitting element Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) Material Enclosure: PBT, Display section: Polycarbonate 0.09 mm 4-core cabtyre cable, PVC, 1 m 3.281 ft long Cable 2 0.09 mm 4-core cabtyre cable, PVC, 3 m 9.843 ft long 2 Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 3) Cable extension Weight Net weight: 10 g approx., Gross weight: 15 g approx. Disc Disc 1.8 mm 0.071 in t = 0.2 mm 0.008 in 1.6 mm 0.063 in Selection Guide U-shaped Convergent Reflective Net weight: 30 g approx., Gross weight: 35 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) The response frequency is the value when the disc, given in the figure below, is rotated. SAFETY LIGHT CURTAINS / SAFETY COMPONENTS HUMAN MACHINE INTERFACES IP64 (IEC) Ambient temperature AREA SENSORS SENSOR OPTIONS NPN open-collector transistor PNP open-collector transistor •• Maximum sink current: 50 mA •• Maximum source current: 50 mA •• Applied voltage: 30 V DC or less (between output and 0 V) •• Applied voltage: 30 V DC or less (between output and +V) •• Residual voltage: 2 V or less (at 50 mA sink current) •• Residual voltage: 2 V or less (at 50 mA source current) 1 V or less (at 16 mA sink current) 1 V or less (at 16 mA source current) Output MICRO PHOTOELECTRIC SENSORS INDUCTIVE PROXIMITY SENSORS 0.05 mm 0.002 in or less Repeatability Environmental resistance PHOTOELECTRIC SENSORS Compact / Cable type 1.6 mm 0.063 in 3) If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. PM-25/PM-45/ PM-65 401 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS U-shaped Micro Photoelectric Sensor PM-25 SERIES PM-45 SERIES PM-65 SERIES Compact / Connector built-in type  PM-65 SERIES Easy connection with a single touch using commercially-available connectors Cable type NPN output Connector attached cable 1 m 3.281 ft, 2 m 6.562 ft, 3 m 9.843 ft, 5 m 16.404 ft Connector attached bending-resistant cable 1 m 3.281 ft, 2 m 6.562 ft, 3 m 9.843 ft, 5 m 16.404 ft Built-in connector PNP output Connector attached cable 1 m 3.281 ft, 2 m 6.562 ft, 3 m 9.843 ft, 5 m 16.404 ft Connector attached bending-resistant cable 1 m 3.281 ft, 2 m 6.562 ft, 3 m 9.843 ft, 5 m 16.404 ft * Recognition Certified * NPN output type only AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PM-K65 PRESSURE / FLOW SENSORS PM-T65W PM-L65 PM-Y65 PM-F65 Type Appearance (mm in) Sensing range Model No. SENSOR OPTIONS K type SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS 22.4 0.882 26 1.024 13.7 0.539 STATIC CONTROL DEVICES T type LASER MARKERS PLC HUMAN MACHINE INTERFACES U-shaped 22.4 0.882 16.7 0.657 PM-R65W L type 13.5 0.531 F type PM-K65 NPN open-collector transistor PM-K65-P PNP open-collector transistor PM-T65 NPN open-collector transistor PM-T65-P PNP open-collector transistor PM-T65W NPN open-collector transistor PM-T65W-P PNP open-collector transistor PM-L65 NPN open-collector transistor 15.7 0.618 PM-L65-P PNP open-collector transistor PM-Y65 NPN open-collector transistor PM-Y65-P PNP open-collector transistor PM-F65 NPN open-collector transistor PM-F65-P PNP open-collector transistor PM-F65W NPN open-collector transistor PM-F65W-P PNP open-collector transistor PM-R65 NPN open-collector transistor PM-R65-P PNP open-collector transistor PM-R65W NPN open-collector transistor PM-R65W-P PNP open-collector transistor 6 mm 0.236 in (fixed) 13.4 0.528 13.4 0.528 22.7 0.894 22.4 0.882 13 0.512 13.4 0.528 22.4 0.882 13.5 0.531 R type Output Output operation 14.9 0.587 26.2 1.031 14.9 0.587 Convergent Reflective PM-25/PM-45/ PM-65 22.4 0.882 Y type Compact / Connector built-in type FA COMPONENTS Selection Guide 26 1.024 26 1.024 ENERGY MANAGEMENT SOLUTIONS UV CURING SYSTEMS PM-R65 7 0.276 MEASUREMENT SENSORS MACHINE VISION SYSTEMS PM-F65W ORDER GUIDE INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS PM-T65 13.4 0.528 22.4 0.882 13 0.512 13.4 0.528 22.4 0.882 Note: P  M-T65W is mounting-compatible with our conventional model “PM-T64W”. PM-F65W(-P) is mounting-compatible with our conventional model “PM-F54(P)”. PM-R65W(-P) is mounting-compatible with our conventional model “PM-R54(P)”. Incorporated with 2 outputs: Light-ON/Dark-ON U-shaped Micro Photoelectric Sensor PM-25 SERIES PM-45 SERIES PM-65 SERIES 402 FIBER SENSORS OPTIONS Designation LASER SENSORS Model No. Connector attached cable Connector attached cable Bendingresistant CN-14A-C1 Length: 1m 3.281 ft CN-14A-C2 Length: 2m 6.562 ft CN-14A-C3 Length: 3m 9.843 ft CN-14A-C5 Length: 5m 16.404 ft CN-14A-R-C1 Length: 1m 3.281 ft CN-14A-R-C2 Length: 2m 6.562 ft CN-14A-R-C3 Length: 3m 9.843 ft CN-14A-R-C5 Length: 5m 16.404 ft CN-14A Connector Connector attached cable Description PHOTOELECTRIC SENSORS • CN-14A(-R)-C□ MICRO PHOTOELECTRIC SENSORS 0.2 mm2 4-core cabtyre cable with connector on one end Cable outer diameter: ø3.7 mm ø0.146 in 0.2 mm2 4-core cabtyre cable with connector on one end Cable outer diameter: ø3.7 mm ø0.146 in AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Connector Contact • CN-14A Set of 10 housings and 40 contacts 4 Housing SPECIFICATIONS Model No. Mounting-compatible with conventional model (Note 2) PM-□65 PM-□65W PNP output PM-□65-P PM-□65W-P EMC Directive, RoHS Directive CE marking directive compliance Sensing range 6 mm 0.236 in (fixed) Minimum sensing object 0.8 × 1.2 mm 0.031 × 0.047 in opaque object Hysteresis 0.05 mm 0.002 in or less Repeatability 0.01 mm 0.0004 in or less Supply voltage 5 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption 15 mA or less NPN open-collector transistor PNP open-collector transistor •• Maximum sink current: 50 mA •• Maximum source current: 50 mA •• Applied voltage: 30 V DC or less (between output and 0 V) •• Applied voltage: 30 V DC or less (between output and +V) •• Residual voltage: 2 V or less (at 50 mA sink current) •• Residual voltage: 2 V or less (at 50 mA source current) 1 V or less (at 16 mA sink current) 1 V or less (at 16 mA source current) Output operation Incorporated with 2 outputs: Light-ON/Dark-ON Short-circuit protection Response time Incorporated Under light received condition: 20 μs or less, Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz) (Note 3) Operation indicator Environmental resistance WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Orange LED (lights up under light received condition) Pollution degree 3 Protection IP40 (IEC) Ambient temperature –25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +80 °C –22 to +176 °F Ambient humidity 5 to 85 % RH, Storage: 5 to 95 % RH Ambient illuminance Fluorescent light: 1,000 ℓx or less at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each Shock resistance 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each Emitting element Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) Material Enclosure: PBT, Display section: Polycarbonate Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 4) Cable length Weight Net weight: 3 g approx., Gross weight: 3 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) PM-T65W is mounting-compatible with our conventional model “PM-T64W”. PM-F65W(-P) is mounting-compatible with our conventional model “PM-F54(P)”. PM-R65W(-P) is mounting-compatible with our conventional model “PM-R54(P)”. 3) The response frequency is the value when the disc, given in the figure below, is rotated. Disc 1.8 mm 0.071 in Disc Recommended connector Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Recommended crimping tool Model No. : YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. t = 0.2 mm 0.008 in 1.6 mm 0.063 in PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS Compact / Connector built-in type NPN output Output INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS Type Item PRESSURE / FLOW SENSORS 1.6 mm 0.063 in 4) If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. Selection Guide U-shaped Convergent Reflective PM-25/PM-45/ PM-65 403 U-shaped Micro Photoelectric Sensor I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS NPN output type I/O circuit diagram MICRO PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Brown Load Black (Note) (Brown) +V ZD1 ZD2 Tr2 (Black) Output 1 (Note) Load 50 mA max. (White) Output 2 (Note) T r1 D (Blue) 0 V Load + – Load 50 mA max. + – White (Note) 5 to 24 V DC ±10 % 5 to 24 V DC ±10 % Blue Note: Ensure to insulate the unused output wire. INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Wiring diagram (PM-25 series / PM-45 series) Color code of cable type and connector attached cable Sensor circuit AREA SENSORS PM-25 SERIES PM-45 SERIES PM-65 SERIES Internal circuit Users’ circuit Output operation Note: Ensure to insulate the unused output wire. Symbols…D: Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2: NPN output transistor WIRE-SAVING SYSTEMS Color code Output operation Output 1 Black Light-ON Output 2 White Dark-ON Terminal arrangement diagram (PM-65 series) MEASUREMENT SENSORS STATIC CONTROL DEVICES 1 LASER MARKERS HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS MACHINE VISION SYSTEMS Convergent Reflective PM-25/PM-45/ PM-65 Designation 1 +V 2 Output 1: Light-ON 3 Output 2: Dark-ON 4 0V Wiring diagram (PM-25 series / PM-45 series) Color code of cable type and connector attached cable Sensor circuit D U-shaped 4 PNP output type I/O circuit diagram UV CURING SYSTEMS Selection Guide 3 Terminal No. PLC FA COMPONENTS 2 (Brown) +V Tr1 Tr2 ZD1 ZD2 Brown Black (Note) + 50 mA max. (Black) Output 1 (Note) 50 mA max. (White) Output 2 (Note) Load (Blue) 0 V + Load – White (Note) 5 to 24 V DC ±10 % Load – 5 to 24 V DC ±10 % Load Blue Note: Ensure to insulate the unused output wire. Internal circuit Users’ circuit Note: Ensure to insulate the unused output wire. Symbols…D: Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2: PNP output transistor Output operation Color code Output operation Output 1 Black Light-ON Output 2 White Dark-ON Terminal arrangement diagram (PM-65 series) 1 2 3 4 Terminal No. Designation 1 +V 2 Output 1: Light-ON 3 Output 2: Dark-ON 4 0V U-shaped Micro Photoelectric Sensor PM-25 SERIES PM-45 SERIES PM-65 SERIES 404 SENSING CHARACTERISTICS (TYPICAL) FIBER SENSORS LASER SENSORS PM-25 series PM-45 series Sensing position Sensing position DarkON DarkON DarkON 5.5 mm 0.217 in 8.4 mm 0.331 in SAFETY LIGHT CURTAINS / SAFETY COMPONENTS ℓ 2 mm 0.079 in Beam axis 0 AREA SENSORS 7 mm 0.276 in ℓ ℓ 2 mm 0.079 in LightON MICRO PHOTOELECTRIC SENSORS DarkON 6 mm 0.236 in ℓ PHOTOELECTRIC SENSORS 1 2 3 0.039 0.079 0.118 Operating point ℓ (mm in) 4 0.157 LightON 0 1 2 3 0.039 0.079 0.118 Operating point ℓ (mm in) 4 0.157 LightON Beam axis 0 1 2 3 0.039 0.079 0.118 Operating point ℓ (mm in) PRESSURE / FLOW SENSORS LightON 4 0.157 0 1 2 3 0.039 0.079 0.118 Operating point ℓ (mm in) 4 0.157 PM-65 series SIMPLE WIRE-SAVING UNITS DarkON DarkON WIRE-SAVING SYSTEMS 8.4 mm 0.331 in MEASUREMENT SENSORS 7 mm 0.276 in ℓ ℓ STATIC CONTROL DEVICES 2 mm 0.079 in Beam axis 0 PARTICULAR USE SENSORS SENSOR OPTIONS Sensing position LightON INDUCTIVE PROXIMITY SENSORS 1 2 3 0.039 0.079 0.118 Operating point ℓ (mm in) 4 0.157 LightON LASER MARKERS 0 1 2 3 0.039 0.079 0.118 Operating point ℓ (mm in) 4 0.157 PLC HUMAN MACHINE INTERFACES PRECAUTIONS FOR PROPER USE • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Refer to p.1552~ for general precautions. PM-45 series • The following conditions must be observed when using screws to mount the sensor unit. Screw Spring washer Flat washer Tightening torque M3 screw 1 pc. ø6 mm ø0.236 in (small round washer) 0.5 N·m ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS M3 screws Mounting Selection Guide Spring washer PM-25 series • The following conditions must be observed when using screws to mount the sensor unit. Screw Spring washer Flat washer Tightening torque M2 screw 1 pc. ø4.3 mm ø0.169 in (small round washer) 0.15 N·m M3 screw 1 pc. ø6 mm ø0.236 in (small round washer) 0.5 N·m < When using M2 screws for mounting > < When using M3 screws for mounting > M2 screws Spring washer Plain washer Outer diameter ø4.3 mm ø0.169 in M3 screws Spring washer Plain washer Outer diameter ø6 mm ø0.236 in When using the optional mounting screw set MS-M2, a spring washer is included. • In case the PM-25 series is used at an ambient temperature of +50 °C +122 °F, or more, make sure to mount it on a metal body. Plain washer Outer diameter ø6 mm ø0.236 in U-shaped Convergent Reflective PM-25/PM-45/ PM-65 PM-65 series • The following conditions must be observed when using screws to mount the sensor unit. Screw M3 screw Spring washer Flat washer Tightening torque 1 pc. ø6 mm ø0.236 in (small round washer) 0.5 N·m M3 screws Spring washer Plain washer Outer diameter ø6 mm ø0.236 in 405 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS U-shaped Micro Photoelectric Sensor PRECAUTIONS FOR PROPER USE Cable extension SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS U-shaped Convergent Reflective PM-25/PM-45/ PM-65 Connection method • Insert the connector attached cable CN‑14A-C□ / CN‑14A-R-C□ in the connector part of this product as shown in the figure below. Lock release lever Total cable length 100 m 328.084 ft CN-14A-C□ / CN-14A-R-C□ Cable attached to sensor +V Extension cable Output + 5 to 24 V DC ±10 % – 0V Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.) Supply voltage: 4.5 V or more But, when the overall cable length, including the cable attached to the sensor, is as given below, there is no need to confirm the voltage. Conductor cross-section area of extension cable Total cable length 0.08 to 0.1 mm2 Up to 5 m 16.404 ft 2 0.2 mm Up to 10 m 32.808 ft 0.3 mm2 Up to 20 m 65.617 ft PM-65 series • Cable extension is possible up to an overall length of 100 m 328.084 ft with a 0.3 mm2, or more, cable. However, since a voltage drop shall occur due to the cable extension, ensure that the power supply voltage at the end of the connector attached cable of the sensor or at the sensor terminals is within the rating. Total cable length 100 m 328.084 ft Connector +V attached cable Extension cable Output + 0V – 5 to 24 V DC ±10 % But, when the overall cable length, including the cable attached to the sensor, is as given below, there is no need to confirm the voltage. Conductor cross-section area of extension cable Total cable length 0.08 to 0.1 mm2 Up to 5 m 16.404 ft 0.2 mm Up to 10 m 32.808 ft 0.3 mm Up to 20 m 65.617 ft 2 2 Connector pin No. Terminal designation +V Output 1 Output 2 0V Disconnection method • Press and hold the lock release lever to disconnect the cable connector. Note: Pulling the cable without pressing the lock release lever in an attempt to disconnect the connector can cause wire breakage in the cable or damage to the connector. Supply voltage: 4.5 V or more Selection Guide Refer to p.1552~ for general precautions. Wiring (PM-65 series) PM-25 series / PM-45 series • Cable extension is possible up to an overall length of 100 m 328.084 ft with a 0.3 mm2, or more, cable. However, since a voltage drop shall occur due to the cable extension, ensure that the power supply voltage at the end of the cable attached to the sensor is within the rating. PARTICULAR USE SENSORS SENSOR OPTIONS PM-25 SERIES PM-45 SERIES PM-65 SERIES When using the product as an S-mark compatible product in Korea • The power supply cable and output cable connected to the product must be less than 10 m 32.808 ft. Others • This device has been developed / produced for industrial use only. • Since the sensor is intended for use inside machines, no special countermeasures have been taken against extraneous light. Take care that extraneous light is not directly incident on the beam receiving section. • Do not use during the initial transient time (50 ms) after the power supply is switched on. • Note that the cable of PM-□25-R loses its flexibility when the ambient temperature decreases to about -10 °C +14 °F. • The cable of PM-□25-R is a bending-resistant cable usable on a moving base. When the sensor is mounted on a moving base, secure the sensor cable joint at the unit in place so that stress is not applied to it. • When storing PM-□25-R, make sure that the cable does not come into contact with the sensing section or operation indicator. • If the sensor is used in a place having excessive dust, periodically clean the emitting and receiving sections with a dry, soft cloth. • If there is a large surge generating equipment, such as, motor, solenoid, electromagnetic valve, etc., in the vicinity of the sensor, use a surge absorber on that equipment. Further, do not run the sensor cables along power lines and use a capacitor between +V and 0 V, if required. Use the sensor after confirming that the surge has been eliminated. U-shaped Micro Photoelectric Sensor PM-25 SERIES PM-45 SERIES PM-65 SERIES DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. PM-K25□ Sensor Operation indicator (Orange) 23.9 0.941 18.7 0.736 13.4 0.528 6 0.236 2 0.079 12 6 0.472 0.236 8 0.315 5.5 Beam 0.217 axis 5 0.197 2-ø3.2 ø0.126 mounting holes ø6 ø0.236 13.4 0.528 6 0.236 Beam size: 1.2 × 0.8 0.047 × 0.031 AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS Operation indicator (Orange) 2 0.079 INDUCTIVE PROXIMITY SENSORS 6 0.236 Beam size: 1.2 × 0.8 0.047 × 0.031 4 0.157 SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS PM-L25(-P) PM-U25□ Sensor PM-F25□ Sensor Operation indicator (Orange) Operation indicator (Orange) 2 0.079 5.5 Beam 0.217 axis 16 0.630 11.5 0.453 2-ø3.2 ø0.126 mounting holes Operation indicator (Orange) Beam size: 1.2 × 0.8 0.047 × 0.031 3 0.118 11.7 0.461 6.2 0.244 Beam size: 1.2 × 0.8 0.047 × 0.031 1.5 0.059 (2 0.079) 5 3.2 0.126 0.197 ø2 ø0.079 1.6 0.063 Elongated mounting hole 1.95 0.077 ø2.5 ø0.098 cable 8 0.315 PM-U25(-P) 12.5 12 8 0.315 0.492 0.472 R1.6 R0.063 ø2.5 ø0.098 cable MEASUREMENT SENSORS STATIC CONTROL DEVICES 6 Beam 0.236 axis Beam axis 13.4 0.528 6 0.236 PARTICULAR USE SENSORS SENSOR OPTIONS ø2.5 ø0.098 cable 2 0.079 PM-K25(-P) 6 3 0.118 0.236 LASER SENSORS MICRO PHOTOELECTRIC SENSORS 1.6 0.063 3.2 0.126 10 12 0.394 0.472 ø2.5 ø0.098 cable FIBER SENSORS PHOTOELECTRIC SENSORS 1.75 0.069 2-elongated mounting holes Beam axis 6 0.236 8 0.315 Sensor Operation indicator (Orange) Operation indicator (Orange) 5.5 Beam 12.3 0.217 axis 0.484 1.7 0.067 PM-L25□ 3 0.118 3 0.118 6 Beam 0.236 axis 406 4 0.157 6.7 0.264 13.4 0.528 6 0.236 LASER MARKERS Operation indicator (Orange) Beam 5.5 axis 0.217 PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS 2 0.079 ø4.8 ø0.189 MACHINE VISION SYSTEMS UV CURING SYSTEMS PM-F25(-P) PM-R25□ Sensor Selection Guide U-shaped Convergent Reflective Beam 6 axis 0.236 Operation indicator (Orange) PM-25/PM-45/ PM-65 4 0.157 6.7 0.264 Operation indicator (Orange) 5.5 Beam 0.217 axis 2 0.079 13.4 0.528 6 0.236 Beam size: 1.5 0.059 1.2 × 0.8 0.047 × 0.031 R1.6 (2 0.079) R0.063 12 8 0.315 0.472 12.5 0.492 ø2.5 ø0.098 cable ø4.8 ø0.189 PM-R25(-P) 5 0.197 3.2 0.126 Elongated mounting hole 1.6 0.063 11.7 0.461 6.2 0.244 3 0.118 ø2 ø0.079 1.95 0.077 407 FIBER SENSORS LASER SENSORS U-shaped Micro Photoelectric Sensor DIMENSIONS (Unit: mm in) Sensor 25.4 1.000 19 0.748 MICRO PHOTOELECTRIC SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS PM-T45□ Sensor Operation indicator (Orange) 3.5 0.138 7 0.276 AREA SENSORS PRESSURE / FLOW SENSORS The CAD data can be downloaded from our website. PM-K45□ PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PM-25 SERIES PM-45 SERIES PM-65 SERIES Operation indicator (Orange) 2-ø3.2 ø0.126 mounting holes 19 0.748 13.4 0.528 6 0.236 Operation indicator (Orange) 2-ø3.8 ø0.150 mounting holes 6 Beam size: 1.2 × 0.8 0.047 × 0.031 0.236 2 0.079 Beam axis 15.2 0.598 2-elongated mounting holes PM-T45 PM-K45 PM-L45□ Sensor STATIC CONTROL DEVICES 26 1.024 Sensor 7 0.276 Operation indicator (Orange) ø2.5 ø0.098 cable 5 0.197 1.5 0.059 14.6 0.575 6 2 Beam size: 0.079 1.2 × 0.8 0.047 × 0.031 0.236 Beam axis 9 0.354 12.6 0.496 8.4 0.331 7.2 0.283 UV CURING SYSTEMS ø2.5 ø0.098 cable Operation indicator (Orange) 19 0.748 13.4 0.528 6 0.236 2-ø3.2 ø0.126 mounting holes 2-ø3.5 ø0.138 mounting holes 7.5 0.295 7 0.276 20.6 6 0.811 0.236 2-elongated mounting holes 4 0.157 ENERGY MANAGEMENT SOLUTIONS MACHINE VISION SYSTEMS 3.5 0.138 3.5 0.138 10 7 0.276 3.2 0.126 0.394 HUMAN MACHINE INTERFACES PM-Y45□ Operation indicator (Orange) 19 0.748 PLC FA COMPONENTS 2.5 0.098 ø2.5 ø0.098 cable WIRE-SAVING SYSTEMS LASER MARKERS 8.4 0.331 3.2 0.126 Operation indicator (R) (Orange) 4.3 0.169 ø2.5 ø0.098 cable SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS 2 0.079 0.244 5.5 0.217 SENSOR OPTIONS 19 0.748 6 0.236 13 17.2 18.1 0.677 0.512 0.713 6.2 Beam axis 13.8 0.543 8.4 0.331 17.2 21.3 0.677 0.839 11 0.433 13.7 0.539 13.4 0.528 6 0.236 26 1.024 Beam size: 1.2 × 0.8 0.047 × 0.031 4.5 0.177 13.4 0.528 6 0.236 14.6 0.575 2 0.079 8.4 0.331 Beam size: 1.2 × 0.8 0.047 × 0.031 2 0.079 Beam axis 12.6 0.496 4.5 0.177 2.5 0.098 Operation indicator (Orange) 2 0.079 PM-L45 Selection Guide PM-F45□ Sensor PM-R45□ Sensor PM-Y45 U-shaped Operation indicator (Orange) Convergent Reflective Operation indicator (Orange) PM-25/PM-45/ PM-65 Operation indicator (Orange) 8.4 0.331 13.6 0.535 2.5 0.098 13.7 0.539 13.4 0.528 6 0.236 Beam size: 1.2 × 0.8 0.047 × 0.031 2 0.079 Beam axis 15.2 0.598 9 0.354 7 0.276 2-ø3.5 ø0.138 mounting holes ø2.5 ø0.098 cable 13 0.512 7 0.276 6 0.236 17.2 0.677 21.3 0.839 Beam size: 1.2 × 0.8 0.047 × 0.031 6 0.236 17.2 21.3 0.677 0.839 13 0.512 7 0.276 2 0.079 9 0.354 7 0.276 Beam axis 15.2 0.598 2-ø3.5 ø0.138 mounting holes ø2.5 ø0.098 cable PM-R45 PM-F45 13.7 0.539 13.4 0.528 6 0.236 Operation indicator (Orange) 8.4 0.331 13.6 0.535 2.5 0.098 U-shaped Micro Photoelectric Sensor PM-25 SERIES PM-45 SERIES PM-65 SERIES DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. PM-K65  PM-K65-P Sensor PM-T65  PM-T65-P Sensor Operation indicator (Orange) 26 1.024 20 0.787 6.5 0.256 Beam size: 1.2 × 0.8 0.047 × 0.031 26 1.024 20 0.787 6 7 0.276 0.236 Beam axis 2 0.079 22.4 0.882 8.3 0.327 3.7 0.146 Sensor 4.1 0.161 1.6 0.063 26 1.024 20 0.787 6.5 0.256 Beam size: 1.2 × 0.8 0.047 × 0.031 6 0.236 (2 0.079) 3 0.118 6 13.4 0.236 0.528 4 0.157 Beam axis Operation indicator (Orange) 10 0.394 14.9 0.587 Sensor 13.4 0.528 6 0.236 Beam size: 1.2 × 0.8 0.047 × 0.031 9 0.354 12.9 0.508 HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS Operation indicator (Orange) MACHINE VISION SYSTEMS 7.2 0.283 20 0.787 LASER MARKERS PLC 6.5 0.256 Beam axis MEASUREMENT SENSORS STATIC CONTROL DEVICES Beam axis 2-mounting holes 8.4 0.331 Operation indicator (Orange) PM-T65W(-P) Sensor 7 6 15.7 0.276 0.236 0.618 3.2 0.126 (2 0.079) INDUCTIVE PROXIMITY SENSORS SIMPLE WIRE-SAVING UNITS 26.2 1.031 Beam axis PRESSURE / FLOW SENSORS WIRE-SAVING SYSTEMS 20 0.787 3.9 0.154 1.7 0.067 13 0.512 MICRO PHOTOELECTRIC SENSORS SENSOR OPTIONS Operation indicator (Orange) 7.4 0.291 6 0.236 PM-Y65  PM-Y65-P 7 0.276 PM-L65  PM-L65-P 2-elongated mounting holes PHOTOELECTRIC SENSORS PARTICULAR USE SENSORS PM-T65(-P) PM-T65W  PM-T65W-P 7.4 0.291 14 0.551 Beam axis 2 0.079 Beam axis PM-K65(-P) 2.3 0.091 Operation indicator (Orange) 6 13.4 0.236 0.528 13.7 0.539 2-mounting holes 2 0.079 3.7 0.146 20 0.787 8.4 0.331 LASER SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Beam size: 1.2 × 0.8 0.047 × 0.031 6 0.236 Operation indicator (Orange) Operation indicator (Orange) FIBER SENSORS AREA SENSORS 13 0.512 4.1 0.161 13.8 0.543 16.7 0.657 7.4 0.291 1.6 0.063 Beam 8.4 0.331 axis 22.4 3.2 0.126 0.882 7.4 0.291 22.4 0.882 8.4 8.3 0.331 0.327 2-elongated mounting holes 6.2 3.2 0.126 0.244 3.5 0.138 2-ø3.2 ø0.126 mounting holes 13.4 0.528 6 0.236 408 UV CURING SYSTEMS 2-ø3.2 ø0.126 mounting holes 26.2 1.031 PM-F65  PM-F65-P Sensor PM-L65(-P) Selection Guide U-shaped Operation indicator (Orange) 2-ø3.5 ø0.138 mounting holes 7 0.276 Operation indicator (Orange) 6.5 0.256 6 0.236 2.5 0.098 3.5 0.138 7 0.276 22.7 Beam 0.894 axis 6 0.236 3 0.118 Beam size: 1.2 × 0.8 0.047 × 0.031 3 0.118 Operation indicator (Orange) 13.4 0.528 6 0.236 Beam 14.9 8.4 0.331 axis 0.587 2 0.079 6.5 0.256 ø2.4 ø0.094 16.3 0.642 8.3 7.7 0.303 0.327 4.1 0.161 PM-Y65(-P) 2.5 0.098 Beam size: 1.2 × 0.8 0.047 × 0.031 13.4 0.528 6 (2 0.079) 0.236 8.4 3.2 0.331 0.126 3.7 2.1 22.4 0.146 0.083 0.882 Operation indicator (Orange) 12.9 0.508 Beam axis 7 0.276 13.5 0.531 Elongated mounting hole PM-F65(-P) Beam axis Convergent Reflective PM-25/PM-45/ PM-65 409 FIBER SENSORS LASER SENSORS U-shaped Micro Photoelectric Sensor DIMENSIONS (Unit: mm in) AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS 13.7 0.539 7 0.276 Sensor Beam axis 13.4 0.528 6 0.236 Operation indicator (Orange) 13 0.512 7 0.276 8.3 0.327 (2 0.079) 9 0.354 13.6 7 0.535 0.276 Beam axis 11.4 0.449 Sensor Operation indicator (Orange) PLC 6.5 0.256 6 0.236 (2 0.079) 13 0.512 7 0.276 Beam size: 1.2 × 0.8 0.047 × 0.031 Operation indicator (Orange) 2-ø3.5 ø0.138 mounting holes 9 0.354 11.4 0.449 7 0.276 13.6 0.535 PM-R65W(-P) U-shaped Convergent Reflective PM-25/PM-45/ PM-65 16.3 0.642 3.7 0.146 4.1 0.161 7 0.276 13.5 0.531 Elongated mounting hole 13.4 0.528 6 0.236 8.3 0.327 Connector attached cable (Optional) 35 1.378 50 1.969 8 0.315 8 0.315 2.5 0.098 ø3.7 ø0.146 cable Beam axis 22.4 0.882 CN-14A-C□   CN-14A-R-C□ L 13.7 0.539 7 0.276 Beam axis UV CURING SYSTEMS Selection Guide 3.2 0.126 PM-R65(-P) PM-R65W  PM-R65W-P LASER MARKERS MACHINE VISION SYSTEMS 8.4 0.331 PM-F65W(-P) STATIC CONTROL DEVICES FA COMPONENTS ø2.4 ø0.094 2.5 0.098 2.1 0.083 WIRE-SAVING SYSTEMS ENERGY MANAGEMENT SOLUTIONS Operation indicator (Orange) 13.4 0.528 6 0.236 8.3 0.327 7.7 0.303 SIMPLE WIRE-SAVING UNITS HUMAN MACHINE INTERFACES 6 6.5 0.236 0.256 22.4 0.882 SENSOR OPTIONS MEASUREMENT SENSORS 3 0.118 3 0.118 Beam size: 1.2 × 0.8 0.047 × 0.031 6.5 0.256 6 0.236 (2 0.079) 2-ø3.5 ø0.138 mounting holes 22.4 0.882 PARTICULAR USE SENSORS Sensor Beam axis Beam size: 1.2 × 0.8 0.047 × 0.031 2.5 0.098 PM-R65  PM-R65-P Operation indicator (Orange) Operation indicator (Orange) Beam axis PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS The CAD data can be downloaded from our website. PM-F65W  PM-F65W-P PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS PM-25 SERIES PM-45 SERIES PM-65 SERIES • Length L Model No. Length L CN-14A(-R)-C1 1,000 39.370 CN-14A(-R)-C2 2,000 78.740 CN-14A(-R)-C3 3,000 118.110 CN-14A(-R)-C5 5,000 196.850 410 MEMO
PM-R65-P 价格&库存

很抱歉,暂时无法提供与“PM-R65-P”相匹配的价格&库存,您可以联系我们找货

免费人工找货
PM-R65-P
  •  国内价格 香港价格
  • 1+101.314681+12.56804
  • 10+92.0990710+11.42485

库存:133