429
FIBER
SENSORS
Connector Built-in U-shaped Micro Photoelectric Sensor
PM-64 SERIES
Related Information
■■General terms and conditions.............. F-7
■■Glossary of terms......................... P.1455~
Amplifier Built-in
■■Sensor selection guide................... P.427~
■■General precautions.................... P.1458~
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Conforming to
EMC Directive
MICRO
PHOTOELECTRIC
SENSORS
Recognition
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
panasonic.net/id/pidsx/global
Easy connection with a single touch
using commercially-available connectors
Built-in connector saves space
This greatly reduces the amount of space taken up
compared to previous models.
The dimension between the beam axis and cable
bending part has been reduced to half at maximum.
UV CURING
SYSTEMS
Selection
Guide
U-shaped
Convergent
Reflective
Previous model
Connector type
PM-□64
25.4 mm
1.000 in
26 mm
1.024 in
22.3 mm
0.878 in
PM-24
PM-44/PM-54
The connector connection type eliminates the extra
work of soldering and insulation processing. In addition,
the connector used is a commercially-available multipurpose connector which is also currently used by the
DP-100 series of digital pressure sensors.
23 mm
0.906 in
11 mm
0.433 in
2.1 mm
0.083 in
PM-64
Can be connected using commerciallyavailable connectors
Approximately
60 %
of previous
model
Detachable
Commerciallyavailable connector
Digital pressure sensor
DP-100 series
Connector Built-in U-shaped Micro Photoelectric Sensor
PM-64 SERIES
APPLICATIONS
430
FIBER
SENSORS
Positioning of a pallet
Sensing the starting point and
overrun of a moving body
Overrun sensing
Dog
Starting point sensing
Overrun
sensing
Sensing the starting point
on a rotating body
The starting
point can be
sensed by
making a slit in
the rotating
body.
LASER
SENSORS
Starting
point
Starting point and overrun is
sensed using the dog on the base.
Pallet is stopped by sensing the dog.
Improved maintenance and workability significantly reduces total cost
The processing cost of the connector cables can be drastically reduced through the use of commercially-available
crimping connectors.
Previous model (Soldering: Connector type)
• Automation is hard because of soldering.
• Insulation processing is required.
• A large space is necessary at the terminal area.
• Connectors are not reliable
(not fully connected or seated).
Insulation processing
Soldering
Previous model (Converted to the cable-type commercially-available connector)
Intermediate box
Commercially-available connector
• Crimping processing is required in two places.
• A set of commercially-available connectors is
necessary.
• There are many processes for cable connections.
Crimping processing
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
Suggestion
PM-64 series (Commercially-available connectors can be used)
MICRO
PHOTOELECTRIC
SENSORS
LASER
MARKERS
• An intermediate box is required.
Crimping processing
PHOTOELECTRIC
SENSORS
• Crimping processing makes automation
possible so the connectors are also highly
reliable.
• Soldering, insulation processing, and an
intermediate box are not necessary.
• Connectors are widely available.
• Mounting in a small space is easy.
• Strongly connected using a locking connector.
• 1 m 3.281 ft, 2 m 6.562 ft, 3 m 9.843 ft, and 5 m
16.404 ft connector cables are available.
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
U-shaped
Convergent
Reflective
PM-64
PM-24
PM-44/PM-54
431
Connector Built-in U-shaped Micro Photoelectric Sensor
PM-64 SERIES
ORDER GUIDE
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Type
K type
MICRO
PHOTOELECTRIC
SENSORS
Appearance (mm in)
AREA
SENSORS
Sensing range
Model No.
PRESSURE /
FLOW
SENSORS
13.7 0.539 in
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
T type
26 1.024 in
15.5 0.610 in
26.2 1.031 in
5 mm 0.197 in
(fixed)
15.7 0.618 in
15.5 0.610 in
22.7
0.894 in
13.8 0.543 in
PLC
F type
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
23
0.906 in
14 0.551 in
R type
UV
CURING
SYSTEMS
NPN open-collector
transistor
PM-K64P
PNP open-collector
transistor
PM-T64
NPN open-collector
transistor
PM-T64P
PNP open-collector
transistor
PM-T64W
(Note)
NPN open-collector
transistor
PM-L64
NPN open-collector
transistor
PM-L64P
PNP open-collector
transistor
PM-Y64
NPN open-collector
transistor
PM-Y64P
PNP open-collector
transistor
PM-F64
NPN open-collector
transistor
PM-F64P
PNP open-collector
transistor
PM-R64
NPN open-collector
transistor
PM-R64P
PNP open-collector
transistor
14 0.551 in
13.4 0.528 in
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
PM-K64
23
0.906 in
L type
WIRE-SAVING
SYSTEMS
Small and built-in connector type
SIMPLE
WIRE-SAVING
UNITS
16.7 0.657 in
Y type
SENSOR
OPTIONS
23
0.906 in
26 1.024 in
PARTICULAR
USE
SENSORS
Output operation
7 0.207 in
23
0.906 in
26 1.024 in
LIGHT
CURTAINS /
SAFETY
COMPONENTS
INDUCTIVE
PROXIMITY
SENSORS
Output
23
0.906 in
13.4 0.528 in
Incorporated with 2 outputs:
Light-ON / Dark-ON
Note: PM-T64W is compatible with our conventional PM-T53(B).
OPTIONS
Selection
Guide
U-shaped
Convergent
Reflective
PM-64
PM-24
PM-44/
PM-54
Designation
Connector
attached
cable
Connector
attached
cable
Flexible
cable
Connector
Model No.
Description
CN-14A-C1
Length: 1m 3.281 ft
CN-14A-C2
Length: 2m 6.562 ft
CN-14A-C3
Length: 3m 9.843 ft
CN-14A-C5
Length: 5m 16.404 ft
CN-14A-R-C1
Length: 1m 3.281 ft
CN-14A-R-C2
Length: 2m 6.562 ft
CN-14A-R-C3
Length: 3m 9.843 ft
CN-14A-R-C5
Length: 5m 16.404 ft
CN-14A
Set of 10 housings and 40 contacts
Connector attached cable
• CN-14A(-R)-C□
0.2 mm2 4-core cabtyre cable with
connector on one end
Cable outer diameter: ø3.7mm
ø0.146 in
Recommended connector
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
Recommended crimping tool
Model No. : YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
Connector
• CN-14A
Contact
4
Housing
Connector Built-in U-shaped Micro Photoelectric Sensor
PM-64 SERIES
SPECIFICATIONS
Model No.
Type
Item
FIBER
SENSORS
T type
L type
NPN output
PM-K64
PM-T64(W)
PM-L64
PM-Y64
PM-F64
PM-R64
PNP output
PM-K64P
PM-T64P
PM-L64P
PM-Y64P
PM-F64P
PM-R64P
Sensing range
Minimum sensing object
Y type
5 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption
15 mA or less
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 0.7 V or less (at 50 mA sink current)
0.4 V or less (at 16 mA sink current)
Utilization category
PNP open-collector transistor
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 0.7 V or less (at 50 mA source current)
0.4 V or less (at 16 mA source current)
DC-12 or DC-13
Incorporated with 2 outputs: Light-ON / Dark-ON
Under light received condition: 20 µs or less
Under light interrupted condition: 100 µs or less
(Response frequency: 1 kHz or more) (Note 4)
Response time
Operation indicator
Orange LED (lights up under light received condition)
Pollution degree
3 (Industrial environment)
–25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +80 °C –22 to +176 °F
Ambient humidity
35 to 85 % RH, Storage: 5 to 95 % RH (Note 5)
Ambient illuminance
Fluorescent light: 1,000 ℓx at the light-receiving face
EMC
EN 60947-5-2
Voltage withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 2,000 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance
15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions for three times each
Emitting element
Infrared LED (Peak emission wavelength: 940 nm 0.037 mil, non-modulated)
Material
MICRO
PHOTOELECTRIC
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
0.01 mm 0.0004 in or less (Note 3)
Output operation
PHOTOELECTRIC
SENSORS
0.8 × 1.8 mm 0.031 × 0.071 in opaque object
Repeatability
Ambient temperature
R type
AREA
SENSORS
0.05 mm 0.002 in or less (Note 2)
Supply voltage
F type
5 mm 0.197 in (fixed)
Hysteresis
Environmental resistance
LASER
SENSORS
Small and built-in connector type
K type
Output
432
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Enclosure: PBT, Slit cover: Polycarbonate
Cable length
Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 6)
Weight
Net weight: 3 g approx.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) This is the value when a sensing object is moved in a lateral direction to the U-shape.
3) This is the value when a sensing object is moved in a lateral direction to the U-shape and when the inserting length of the sensing board is 5 mm 0.197 in.
4) The response frequency is the value when the disc, given in the figure below, is rotated.
Disk
Disk
Selection
Guide
U-shaped
Convergent
Reflective
1.8 mm 0.071 in
PM-64
PM-24
t = 0.2 mm 0.008 in
1.6 mm 0.063 in
1.6 mm 0.063 in
5) 5-35% RH in an ambient temperature of +23 °C +73.4 °F.
6) Confirm that the sensor terminal voltage is more than 4.5 V when using an extension of over 20 m 65.617 ft.
PM-44/
PM-54
433
Connector Built-in U-shaped Micro Photoelectric Sensor
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
PM-□64(W)
NPN output type
I/O circuit diagram
MICRO
PHOTOELECTRIC
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
(Brown) +V
ZD1
(Black) Output 1 Load
(Note 1,2)
50 mA max.
(White) Output 2 (Note 1,2)
Tr1
ZD2
Tr2
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
–
5 to 24 V DC
±10 %
1
Users’ circuit
Notes: 1) Make sure to connect terminals correctly as the sensor does not
incorporate a reverse polarity protection circuit.
Further, the output is not incorporated with a short-circuit
protection circuit. Do not connect it directly to a power supply or a
capacitive load. Faulty wiring may result in damage.
2) Ensure to insulate the unused output wire.
U-shaped
Convergent
Reflective
I/O circuit diagram
1
+V
2
Output1: Light-ON
3
Output2: Dark-ON
4
0V
Terminal arrangement diagram
Color code of connector attached cable
(Brown) +V
ZD1
Tr1
ZD2
50 mA max.
(Black) Output 1 (Note 1,2)
50 mA max.
Tr2
(White) Output 2 (Note 1,2)
Load
(Blue) 0 V
Internal circuit
+
Load
–
5 to 24 V DC
±10 %
1
Users’ circuit
Notes: 1) Make sure to connect terminals correctly as the sensor does not
incorporate a reverse polarity protection circuit.
Further, the output is not incorporated with a short-circuit
protection circuit. Do not connect it directly to a power supply or a
capacitive load. Faulty wiring may result in damage.
2) Ensure to insulate the unused output wire.
SENSING CHARACTERISTICS (TYPICAL)
PM-K64(P) PM-L64(P)
Sensing position
PM-44/
PM-54
Designation
PNP output type
PM-64
PM-24
4
3
PM-□64P
Symbols … ZD1, ZD2 : Surge absorption zener diode
Tr1,Tr2 : PNP output transistor
Selection
Guide
2
Symbols … ZD1, ZD2 : Surge absorption zener diode
Tr1,Tr2 : NPN output transistor
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
+
Terminal No.
Internal circuit
Sensor circuit
HUMAN
MACHINE
INTERFACES
Load
50 mA max.
(Blue) 0 V
LASER
MARKERS
PLC
Terminal arrangement diagram
Color code of connector attached cable
Sensor circuit
AREA
SENSORS
PM-64 SERIES
DarkON
DarkON
9 mm 0.354 in
ℓ
7 mm 0.276 in
ℓ
2.6 mm
0.102 in
LightON 0
Beam
axis
1
2
3
0.039
0.079
0.118
Operating point ℓ (mm in)
4
0.157
LightON
1
2
3
0.039
0.079
0.118
Operating point ℓ (mm in)
4
0.157
2
3
4
Terminal No.
Designation
1
+V
2
Output1: Light-ON
3
Output2: Dark-ON
4
0V
Connector Built-in U-shaped Micro Photoelectric Sensor
PRECAUTIONS FOR PROPER USE
PM-64 SERIES
434
Refer to p.1458~ for general precautions.
LASER
SENSORS
Cable extension
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
• Cable extension is possible up to an overall length of
100 m 328.084 ft with a 0.3 mm2, or more, cable.
However, since a voltage drop shall occur due to the
cable extension, ensure that the power supply voltage
at the end of the cable attached to the sensor or at the
sensor terminals is within the rating.
Make sure to connect terminals correctly as the
sensor does not incorporate a reverse polarity
protection circuit.
Further, the output is not incorporated with a
short-circuit protection circuit. Do not connect it
directly to a power supply or a capacitive load.
Faulty wiring may result in damage.
Mounting
• When fixing the sensor with screws, use M3 screws and
the tightening torque should be 0.5 N·m or less.
Further, use small, round type plain washers (ø6 mm
ø0.236 in).
Total cable length 100 m 328.084 ft
Connector
+V
attached cable
Extension cable
Output
Supply voltage:
4.5 V or more
0V
+
–
5 to 24V DC
±10 %
But, when the overall cable length, including the cable
attached to the sensor, is as given below, there is no
need to confirm the voltage.
)
Wiring
Connection method
• Insert the connector attached cable
CN-14A(-R)-C□ in the connector part
of this product as shown in the right
figure.
1
2
3
4
Connector pin No.
Terminal designation
1
+V
2
Projection
CN-14A(-R)-C□
Housing: PAP-04V-S
Manufactured by J.S.T.
Mfg. Co., Ltd.
(
3
Output 1 Output 2
)
4
0V
Disconnection method
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Conductor crosssection area of
extension cable
Total cable length
SIMPLE
WIRE-SAVING
UNITS
0.08 to 0.1 mm2
Up to 5 m 16.404 ft
WIRE-SAVING
SYSTEMS
2
0.2 mm
Up to 10 m 32.808 ft
0.3 mm2
Up to 20 m 65.617 ft
Others
(
PHOTOELECTRIC
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
M3 screws
Spring washer
Plain washer
Outer diameter
ø6 mm
ø0.236 in
FIBER
SENSORS
• Since the sensor is intended for
use inside machines, no special
countermeasures have been
taken against extraneous light.
Take care that extraneous light is
not directly incident on the beam
receiving section.
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
• If the sensor is used in a place having excessive dust,
periodically clean the emitting and receiving sections with
a dry, soft cloth.
• If there is a large surge generating equipment, such as,
motor, solenoid, electromagnetic valve, etc., in the vicinity
of the sensor, use a surge absorber on that equipment.
Further, do not run the sensor cables along power lines
and use a capacitor between +V and 0 V, if required.
Use the sensor after confirming that the surge has been
eliminated.
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
U-shaped
Convergent
Reflective
• Pressing the projection of the connector attached cable,
pull out the connector.
PM-64
Note: Take care that if the cable is pulled out without pressing the projection,
the cable may break.
PM-44/
PM-54
PM-24
435
FIBER
SENSORS
LASER
SENSORS
Connector Built-in U-shaped Micro Photoelectric Sensor
DIMENSIONS (Unit: mm in)
AREA
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Sensor
26
1.024
20
0.787
PM-T64(P)
Sensor
13.7
0.539
7
0.276
3.5
0.138
7
0.276
3
0.118
Beam axis
2-ø3.2 ø0.126 mounting holes
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
The CAD data in the dimensions can be downloaded from our website.
PM-K64(P)
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
PM-64 SERIES
13.4
0.528
5
0.197
7
0.276
Operation indicator
(Orange)
2.6
0.102
6.8
0.268 Beam axis width:
0.8 0.031
26
1.024
Beam axis
9
0.354
Locking 3.2
13.8
part
0.126 0.543
23
0.906
7.4
0.291
6.2
4.1
0.244
0.161
3.2
0.126
(2.1
0.083 )
3.7
0.146
1.7
0.067
20
0.787
SIMPLE
WIRE-SAVING
UNITS
Beam axis width:
0.8 0.031
13
0.512
1.6
0.063
20
0.787
13.4
0.528
5
0.197
2.6
0.102
Beam axis
9
0.354
23
0.906
7.4
0.291
2-mounting oblong holes
Connector attached cable CN-14A(-R)-C□ (Optional)
Beam axis
Operation indicator
(Orange)
10.5
0.413
2.1
0.083
(
Locking
part
2-mounting
oblong holes
)
Connector attached cable
CN-14A(-R)-C□ (Optional)
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
PM-T64W
Sensor
STATIC
ELECTRICITY
PREVENTION
DEVICES
16.7
0.657
10
0.394
LASER
MARKERS
PLC
7
0.276
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Beam axis width:
0.8 0.031
4.1
0.161
3.2
0.126
13
0.512
6
0.236
4
0.157
Beam axis
23
0.906
20
0.787
26
1.024
1.6
0.063
(2.1
0.083)
Locking
part
2-mounting
oblong holes
Sensor
PM-44/
PM-54
9
0.354
Beam axis
PM-L64
9
0.354
7.2
0.283
20
0.787
2-ø3.2 ø0.126 mounting holes
PM-F64(P)
Center of beam axis
and boss
Beam axis width:
0.8 0.031
Connector attached cable
CN-14A(-R)-C□ (Optional)
Sensor
6.5
0.256
2.5
0.098
Operation indicator (Orange)
13.4
0.528
5
0.197
7
0.276
2.5
0.098
2.6
0.102
9
0.354
23
0.906
6.4
0.252 Beam axis width:
0.8 0.031
2.6
0.102
12.9
0.508
PM-L64
Beam axis and boss
Beam axis
Beam axis
15.5
0.610
Beam axis width:
0.8 0.031
7
0.276
Locking part
12.8
0.504
13.8
0.543
5
0.197
6.4
0.252
3
0.118
Operation indicator (Orange)
2.1
(0.083
)
Connector attached cable
CN-14A(-R)-C□ (Optional)
12.8
0.504
13.4
0.528
5
0.197
2-ø3.5 ø0.138 mounting holes
3.5
0.138
7
0.276
22.7
0.894
Operation indicator (Orange)
Locking part
Connector attached cable
CN-14A(-R)-C□ (Optional)
PM-Y64(P)
7
0.276
Beam axis
2-mounting oblong holes
9
15.5 0.354
0.610
10.5
0.413
3.5
0.138
7
15.7 0.276
0.618
3.2
0.126
2.6
8.3
0.102 0.327
Beam axis
9
0.354
26.2
1.031
20
0.787
2.1
(0.083
)
13.4
0.528
5
0.197
7.4
0.291
U-shaped
PM-24
2.6
0.102
Sensor
1.7 0.067
3.7 0.146
Operation indicator
(Orange)
Convergent
Reflective
PM-64
PM-L64(P)
ø2.4 ø0.094
Center of beam
axis and boss
16.3
0.642
8.2
0.323
Locking part
Connector attached cable
CN-14A(-R)-C□ (Optional)
2.1
( 0.083
)
7
0.276
14
0.551
ø3.2 ø0.126
mounting holes
Connector Built-in U-shaped Micro Photoelectric Sensor
DIMENSIONS (Unit: mm in)
PM-64 SERIES
The CAD data in the dimensions can be downloaded from our website.
PM-R64(P)
PHOTOELECTRIC
SENSORS
3
0.118
MICRO
PHOTOELECTRIC
SENSORS
Beam axis and boss
7
0.276
Operation indicator (Orange)
Center of beam axis
and boss
2.5
0.098
2.6
0.102
7
0.276
AREA
SENSORS
Center of beam
axis and boss
13.4
0.528
5
0.197
LIGHT
CURTAINS /
SAFETY
COMPONENTS
Beam axis width:
0.8 0.031
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
16.3
23
0.642 0.906 9
0.354
8.2
0.323
7
0.276
14
0.551
ø3.2 ø0.126
mounting holes
PARTICULAR
USE
SENSORS
2.1
(0.083
)
Locking part
SENSOR
OPTIONS
Connector attached cable
CN-14A(-R)-C□ (Optional)
SIMPLE
WIRE-SAVING
UNITS
CN-14A-C□ CN-14A-R-C□
Connector attached cable (Optional)
L
(
)
35
1.378
8
0.315
(
)
FIBER
SENSORS
LASER
SENSORS
Sensor
ø2.4
ø0.094
436
(
)
50
1.969
8
0.315
ø3.7 ø0.146 cable
(
)
• Length L
Model No.
Length L
CN-14A(-R)-C1
1,000 39.370
CN-14A(-R)-C2
2,000 78.740
CN-14A(-R)-C3
3,000 118.110
CN-14A(-R)-C5
5,000 196.850
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
U-shaped
Convergent
Reflective
PM-64
PM-24
PM-44/
PM-54