PM4HA-H-24VS

PM4HA-H-24VS

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    ANALOG TIMER MF DIN48 1S-500HR

  • 数据手册
  • 价格&库存
PM4HA-H-24VS 数据手册
PM4H-A/S/M PM4H-A PM4H-S PM4H-M DIN48 SIZE MULTI-RANGE ANALOG TIMER UL File No.: E122222 CSA File No.: LR39291 FEATURES 48 1.890 62.5 2.461 48 1.890 Socket mount mm inch Flush mount • Front panel of IP65 type is protected against water-splash and dust • 100-240V AC free-voltage input, 48-125V DC type available • Built-in Screw terminals • Screw terminal type is used for easy wiring and reducing additional cost for accessories. • 8 different operation modes: (PM4H-A) • Tube base with pin style terminals • Multiple time ranges — 1 s to 500 h (Max.) • Short body — 62.5mm 2.461 inch (screw terminal type) PRODUCT TYPE Type Contact arrangement Operation mode Protective construction Time range Rated operating voltage 100 to 240V AC PM4H-A IP65 8 operation modes • Pulse ON-delay • Pulse Flicker • Pulse ON-flicker • Differential ON/OFF-delay (1) (2) • Signal OFF-delay • Pulse One-shot • Pulse One-cycle 24V AC/DC 12V DC Relay Timed-out 2 Form C 100 to 240V AC IP50 24V AC/DC 12V DC 100 to 240V AC IP65 PM4H-S Relay Timed-out 2 Form C Power ON-delay 24V AC/DC 12V DC 16 selectable ranges 1s to 500h 100 to 240V AC IP50 24V AC/DC 12V DC 100 to 240V AC PM4H-M IP65 5 operation modes (With instantaneous contact) • Power ON-delay • Power Flicker • Power ON-flicker • Power One-shot • Power One-cycle 24V AC/DC Relay Timed-out 1 Form C Instantaneous 1 Form C 12V DC 100 to 240V AC IP50 24V AC/DC 12V DC Terminal type Part No. 11 pin Screw terminal 11 pin Screw terminal 11 pin Screw terminal 11 pin Screw terminal 11 pin Screw terminal 11 pin Screw terminal 8 pin Screw terminal 8 pin Screw terminal 8 pin Screw terminal 8 pin Screw terminal 8 pin Screw terminal 8 pin Screw terminal 8 pin Screw terminal 8 pin Screw terminal 8 pin Screw terminal 8 pin Screw terminal 8 pin Screw terminal 8 pin Screw terminal PM4HA-H-AC240VW PM4HA-H-AC240VSW PM4HA-H-24VW PM4HA-H-24VSW PM4HA-H-DC12VW PM4HA-H-DC12VSW PM4HA-H-AC240V PM4HA-H-AC240VS PM4HA-H-24V PM4HA-H-24VS PM4HA-H-DC12V PM4HA-H-DC12VS PM4HS-H-AC240VW PM4HS-H-AC240VSW PM4HS-H-24VW PM4HS-H-24VSW PM4HS-H-DC12VW PM4HS-H-DC12VSW PM4HS-H-AC240V PM4HS-H-AC240VS PM4HS-H-24V PM4HS-H-24VS PM4HS-H-DC12V PM4HS-H-DC12VS PM4HM-H-AC240VW PM4HM-H-AC240VSW PM4HM-H-24VW PM4HM-H-24VSW PM4HM-H-DC12VW PM4HM-H-DC12VSW PM4HM-H-AC240V PM4HM-H-AC240VS PM4HM-H-24V PM4HM-H-24VS PM4HM-H-DC12V PM4HM-H-DC12VS If you use this timer under harsh environment, please order above sealed type (IP65 type). IP65 type — Protection dust and water jet splay on the front face. When ordering CE type, please order the Part No. with suffix CE. (e.g. PM4HA-H-AC240VWCE) TIME RANGE Time unit Scale 1 5 10 50 Control time range sec min hrs 10h 1.0h to 10h 0.1s to 1s 0.1 min to 1 min 0.1h to 1h 0.5s to 5s 0.5 min to 5 min 0.5h to 5h 5h to 50h 1.0s to 10s 1.0 min to 10 min 1.0h to 10h 10h to 100h 5s to 50s 5 min to 50 min 5h to 50h 50h to 500h Note: 0 setting is for instantaneous output operation. 12 02/2003 PM4H-A/PM4H-S/PM4H-M All types of PM4H timer have multi-time range. 16 time ranges are selectable. 1s to 500h (Max. range) is controlled. PM4H-A/S/M CHARACTERISTICS Type Item PM4H-A Rated operating voltage Rated frequency Rated power consumption Output rating PM4H-S 100 to 240V AC, 12V DC, 24V AC/DC, 48 to 125V DC 50/60Hz common (AC operating type) Approx. 10VA (100 to 240V AC) Approx. 2.5VA (24V AC) Approx. 2W (12V DC, 24V DC, 48 to 125V DC) 5A 250V AC (resistive load) PM4H-M Pulse ON-delay Power ON-delay Pulse Flicker Power Flicker Pulse ON-Flicker Power ON-flicker Power ON-delay Differential ON/OFF-delay (1) (2) Operating mode Power One-shot Signal OFF-delay Power One-cycle Pulse One-shot (with instantaneous contact) Pulse One-cycle 1s to 500h (Max.) 16 time ranges switchable Time range ±0.3% (power off time change at the range of 0.1s to 1h) Operating time fluctuation Time Setting error ±5% (Full-scale value) accuracy ±0.5% (at the operating voltage changes between 85 to 110%) Note:) Voltage error Temperature error ±2% (at 20°C ambient temp. at the range of –10 to +50°C +14 to +122°F) Timed-out 1 Form C Contact arrangement Timed-out 2 Form C Instantaneous 1 Form C Contact Contact resistance (Initial value) Max. 100mΩ (at 1A 6V DC) Contact material Silver alloy Au flash on Silver alloy Mechanical (contact) 2×107 Life Electrical (contact) 105 (at rated control capacity) Allowable operating voltage range 85 to 110% of rated operating voltage (at 20°C coil temp.) Between live and dead metal parts Between input and output Insulation resistance (Initial value) Min. 100MΩ (At 500V DC) Between contacts of different poles Between contacts of same pole Electrical 2,000Vrms for 1 min Between live and dead metal parts function 2,000Vrms for 1 min Between input and output Breakdown voltage (Initial value) 2,000Vrms for 1 min Between contacts of different poles 1,000Vrms for 1 min Between contacts of same pole Min. power off time 100ms Max. temperature rise 55°C 131°F 65°C 149°F Functional Min. 98m/s2 (4 times on 3 axes) Shock resistance Min. 980m/s2 (5 times on 3 axes) Destructive Mechanical function 10 to 55Hz: 1 cycle/min double amplitude of 0.5mm (10min on 3 axes) Functional Vibration resistance 10 to 55Hz: 1 cycle/min double amplitude of 0.75mm (1h on 3 axes) Destructive Ambient temperature –10 to +50°C +14 to +122°F Ambient humidity Max. 85%RH Operating condition Atmospheric pressure 860 to 1,060hPa Ripple factor (DC type) 20% Protective construction IP65 on front panel (using rubber gasket ATC18002) 100g 3.527 oz (Pin type) Others Weight 110g 3.880 oz (Screw terminal type) Note: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% ripple factor for DC), 20°C 68°F ambient temperature, and 1s power off time. 2) For the 1s range, the tolerance for each specification becomes ±10ms. Rating WIRING DIAGRAMS PM4H-A Pin type • Timed-out 2 Form C COM Reset Stop input input Signal input PM4H-S Pin type • Timed-out 2 Form C Screw terminal type • Timed-out contact 2 Form C N.C. COM Screw terminal type • Timed-out 2 Form C N.C. N.O. COM COM N.O. N.O. N.C. N.C. N.O. N.C. N.O. COM COM COM (–) Operating (+) voltage PM4H-M Pin type • Timed-out 1 Form C • Instantaneous 1 Form C N.C. Operating (+) voltage (–) Stop input Signal input Reset input COM Operating voltage (+) (+) Operating (–) voltage 1) DC Type PM4H-A COM N.C. N.O. COM (–) Type Screw terminal type • Timed-out 1 Form C • Instantaneous 1 Form C N.C. N.O. N.O. N.C. N.C. N.O. PM4H-S PM4H-M Pin Connect the terminal  to negative (–), and the terminal  to positive (+). Connect the terminal  to negative (–), and the terminal  to positive (+). Screw terminal Connect the terminal x to negative (–), and the terminal z to positive (+). N.O. N.O. N.C. N.C. N.O. 2) Contact COM COM (–) Operating voltage (+) (+) Operating (–) voltage Timed-out contact Instantaneous contact 13 02/2003 PM4H-A/S/M PARTS NAME PM4H-S PM4H-A PM4H-M Power indicator LED Operation indicator LED Hand Time indicator window Set dial Time range indicator Operation mode indicator Time range selector 16 time settings selectable 1 s to 500 h Instantaneous output area 1s 5s 10s 50s 1min 5min 10min 50min When the hand is in this area, instantaneous operation starts. 1h 5h 10h 50h 10h 50h 100h 500h Operation mode selector Selectable from 8 operation modes ON : Pulse ON-delay FL : Pulse Flicker FO : Pulse ON-flicker OF1 : Differential ON/OFF-delay (1) SF : Signal OFF-delay OS : Pulse One-shot OF2 : Differential ON/OFF-delay (2) OC : Pulse One-cycle Operation mode selector Selectable from 5 operation modes ON : Power ON-delay FL : Power flicker FO : Power ON-flicker OS : Power One-shot OC : Power One-cycle DIMENSIONS mm inch • PM4H- Screw terminal type (Flush mount) Pin type (Flush mount/Surface mount) 62.5 2.461 ∅41 ∅1.614 48 1.890 0 44.5 1.752 48 1.890 0 • Panel mount dimensions (with mounting frame) Screw terminal type Rubber gasket ATC 18002 (attached) 48 1.890 Rubber gasket ATC 18002 1 .039 • Surface mount dimensions Socket mount (Pin type) Din rail socket ATC18003 (8 pin) ATC18004 (11 pin) Mounting rail AT8-DLA1 95.3 (8 pin) 3.752 101.0 (11 pin) 3.976 44.5 1.752 48 1.890 0 61.5 2.421 66 2.6 48 1.890 • Panel cut out dimensions Standard cut out dimensions are shown below. Use mounting frame (AT8-DA4) and rubber gasket (ATC18002). 45+0.6 0 1.772+.024 0 Panel Mounting frame AT8-DA4 50 1.969 66 2.6 14.5 .571 Socket (8 pin) AT8-RR When 11 pin timer is used, use the socket. AT8-DP11 Panel 50 1.969 0 66.5 2.618 44.5 1.752 Pin type Mounting frame AT8-DA4 (attached) 48 1.890 6.0 12.0 .236 .472 48 1.890 ∅41 ∅1.614 6.0 12.0 .236 .472 48 1.890 Min. 80 3.150 77 3.031 • Adjacent mounting 45+0.6 0 1.772+.024 0 A A = (48×n–2.5)+0.6 0 A = (1.890×n–.098)+.024 0 45+0.6 0 1.772+.024 0 Note: 1. The proper thickness of mounting panel is between 1 to 5mm. 2. Adjacent mount is less water-resistant. Min. 80 3.150 14 02/2003 PM4H-A/S/M OPERATION MODE PM4H-A Operation mode Pulse ON-delay ON The new settings are valid after power OFF  ON  LED lighting LED flickering  T: Setting time t1, t2, ta, tb
PM4HA-H-24VS 价格&库存

很抱歉,暂时无法提供与“PM4HA-H-24VS”相匹配的价格&库存,您可以联系我们找货

免费人工找货