PM4H-F
DIN48 SIZE ANALOG
MULTIRANGE POWER
OFF-DELAY TIMERS
PM4H-F
UL File No.: E122222
CSA File No.: LR39291
Features
1. Switch operation times between three types of time ranges of 1 s to 10 s and 1
min to 10 min.
2. Instantaneous reset available.
3. The shorter body makes it easier to use.
4. Compliant with UL, CSA, CE and LLOYD.
48
1.890
48
1.890
62.5
2.461
mm inch
RoHS Directive compatibility information
http://www.nais-e.com/
Specifications
Type
Item
Rated operating voltage
Rated frequency
Rating
Time
accuracy *1
Contact
Life
Rated power consumption
Rated control capacity
Operation mode
Time range
Operation time fluctuation
Setting error
Voltage error
Temperature error
Contact arrangement
Contact resistance (Initial value)
Contact material
Mechanical (contact)
Electrical (contact)
Allowable operating voltage range
Insulation resistance (Initial value)
Electrical
function
Breakdown voltage (Initial value)
Min. power supply width
Min. reset time
Max. temperature rise
Vibration resistance
Mechanical
function
Operating
condition
Others
Shock resistance
Functional
Destructive
Functional
Destructive
Ambient temperature
Ambient humidity
Atmospheric pressure
Ripple factor (DC type)
Protective construction
Weight
PM4H-F8R
PM4H-F11R
100 to 120V AC, 200 to 240V AC, 24V AC, 12V DC, 24V DC
50/60Hz common (AC operating type)
Approx. 1.6VA (100 to 120V AC, 200 to 240V AC), Approx. 2.3VA (24V AC)
Approx. 1.1W (12V DC, 24V DC)
3A 250V AC (resistive load)
Power OFF-delay
Power OFF-delay (with reset)
1s to 10s: 3 range switchable 1 min to 10 min: 3 range selectable
±0.3%
±5% (Full-scale value)
±0.5% (at the operating voltage changes between 85 to 110%)
±2% (at 20°C ambient temp. at the range of –10 to +50°C +14 to +122°F)
Timed-out 2 Form C
Timed-out 1 Form C
Timed-out 2 Form C
Max. 100mΩ (at 1A 6V DC)
Au flash on Silver alloy
107
5
10 (at rated control capacity)
85 to 110% of rated operating voltage (at 20°C coil temp.), 90 to 110% (DC Type)
Between live and dead metal parts
Between input and output
Min. 100MΩ
(At 500V DC)
Between contacts of different poles (*3)
Between contacts of same pole
1,500Vrms for 1 min Between live and dead metal parts
1,500Vrms for 1 min Between input and output
1,000Vrms for 1 min Between contacts of different poles (*3)
750Vrms for 1 min Between contacts of same pole
s range type: 100ms
min range type: 2s
50ms
55°C 131°F
10 to 55Hz: 1 cycle/min double amplitude of 0.25mm (10min on 3 axes)
10 to 55Hz: 1 cycle/min double amplitude of 0.375mm (1hr on 3 axes)
Min. 98m/s2 (4 times on 3 axes)
Min. 980m/s2 (5 times on 3 axes)
–10 to +50°C +14 to +122°F
30 to 85%RH (non-condensing)
860 to 1,060hPa
20%
IP65 on front panel (using rubber gasket ATC18002)
100g 3.527 oz (Pin type), 110g 3.880 oz (Screw terminal type)
PM4H-F8
*Notes: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% ripple
factor for DC), 20°C 68°F ambient temperature.
2) For the 1s range, the tolerance for each specification becomes ±10ms. When the power goes on, in rush current (0.3A) flows. Cautions should be taken. The
minimum power supplying time after forced reset input is 2s or more.
3) Between contacts of different pools for PM4H-F8, PM4H-F11R types only.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
PM4H-F
Time range
Time range
unit
Time range
1
5
10
s range type
min range type
0.04s to 1s
0.2s to 5s
0.4s to 10s
0.04 min to 1 min
0.2 min to 5 min
0.4 min to 10 min
Product types
Type
Operation
mode
Contact arrangement
Time range
3 selectable time ranges
over 1s to 10s
3 selectable time ranges
over 1 min to 10 min
PM4H-F8
Power
OFF-delay
(without reset)
Relay Timed-out
2 Form C
3 selectable time ranges
over 1s to 10s
3 selectable time ranges
over 1 min to 10 min
3 selectable time ranges
over 1s to 10s
PM4H-F8R
Power
OFF-delay
(with
instantaneous
reset)
3 selectable time ranges
over 1 min to 10 min
Relay Timed-out
1 Form C
3 selectable time ranges
over 1s to 10s
3 selectable time ranges
over 1 min to 10 min
Protective Rated operating
construction
voltage
100 to 120V AC
200 to 240V AC
24V AC
12V DC
24V DC
IP65
100 to 120V AC
200 to 240V AC
24V AC
12V DC
24V DC
100 to 120V AC
200 to 240V AC
24V AC
12V DC
24V DC
IP50
100 to 120V AC
200 to 240V AC
24V AC
12V DC
24V DC
100 to 120V AC
200 to 240V AC
24V AC
12V DC
24V DC
IP65
100 to 120V AC
200 to 240V AC
24V AC
12V DC
24V DC
100 to 120V AC
200 to 240V AC
24V AC
12V DC
24V DC
IP50
100 to 120V AC
200 to 240V AC
24V AC
12V DC
24V DC
Terminal
type
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
8 pins
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Part number
PM4HF8-S-AC120VW
PM4HF8-S-AC240VW
PM4HF8-S-AC24VW
PM4HF8-S-DC12VW
PM4HF8-S-DC24VW
PM4HF8-M-AC120VW
PM4HF8-M-AC240VW
PM4HF8-M-AC24VW
PM4HF8-M-DC12VW
PM4HF8-M-DC24VW
PM4HF8-S-AC120V
PM4HF8-S-AC240V
PM4HF8-S-AC24V
PM4HF8-S-DC12V
PM4HF8-S-DC24V
PM4HF8-M-AC120V
PM4HF8-M-AC240V
PM4HF8-M-AC24V
PM4HF8-M-DC12V
PM4HF8-M-DC24V
PM4HF8R-S-AC120VW
PM4HF8R-S-AC240VW
PM4HF8R-S-AC24VW
PM4HF8R-S-DC12VW
PM4HF8R-S-DC24VW
PM4HF8R-M-AC120VW
PM4HF8R-M-AC240VW
PM4HF8R-M-AC24VW
PM4HF8R-M-DC12VW
PM4HF8R-M-DC24VW
PM4HF8R-S-AC120V
PM4HF8R-S-AC240V
PM4HF8R-S-AC24V
PM4HF8R-S-DC12V
PM4HF8R-S-DC24V
PM4HF8R-M-AC120V
PM4HF8R-M-AC240V
PM4HF8R-M-AC24V
PM4HF8R-M-DC12V
PM4HF8R-M-DC24V
PM4H-F
Type
Operation
mode
Contact arrangement
Protective Rated operating
construction
voltage
Time range
100 to 120V AC
200 to 240V AC
24V AC
IP65
12V DC
24V DC
3 selectable time ranges
over 1s to 10s
100 to 120V AC
200 to 240V AC
24V AC
IP50
12V DC
PM4H-F11R
Power
OFF-delay
(with
instantaneous
reset)
24V DC
Relay Timed-out
2 Form C
100 to 120V AC
200 to 240V AC
24V AC
IP65
12V DC
24V DC
3 selectable time ranges
over 1 min to 10 min
100 to 120V AC
200 to 240V AC
24V AC
IP50
12V DC
24V DC
Terminal
type
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
11 pins
Screw terminal
6.0
.236
• Pin type (Flush mount/surface mount)
62.5
2.461
48
1.890
44.5
1.752
48
1.890
12.0
.472
6.0
.236
66.5
2.618
41 dia.
1.614 dia.
48
1.890
12.0
.472
41 dia.
1.614 dia.
48
1.890
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
PM4HF11R-S-AC120VW
PM4HF11R-S-AC120VSW
PM4HF11R-S-AC240VW
PM4HF11R-S-AC240VSW
PM4HF11R-S-AC24VW
PM4HF11R-S-AC24VSW
PM4HF11R-S-DC12VW
PM4HF11R-S-DC12VSW
PM4HF11R-S-DC24VW
PM4HF11R-S-DC24VSW
PM4HF11R-S-AC120V
PM4HF11R-S-AC120VS
PM4HF11R-S-AC240V
PM4HF11R-S-AC240VS
PM4HF11R-S-AC24V
PM4HF11R-S-AC24VS
PM4HF11R-S-DC12V
PM4HF11R-S-DC12VS
PM4HF11R-S-DC24V
PM4HF11R-S-DC24VS
PM4HF11R-M-AC120VW
PM4HF11R-M-AC120VSW
PM4HF11R-M-AC240VW
PM4HF11R-M-AC240VSW
PM4HF11R-M-AC24VW
PM4HF11R-M-AC24VSW
PM4HF11R-M-DC12VW
PM4HF11R-M-DC12VSW
PM4HF11R-M-DC24VW
PM4HF11R-M-DC24VSW
PM4HF11R-M-AC120V
PM4HF11R-M-AC120VS
PM4HF11R-M-AC240V
PM4HF11R-M-AC240VS
PM4HF11R-M-AC24V
PM4HF11R-M-AC24VS
PM4HF11R-M-DC12V
PM4HF11R-M-DC12VS
PM4HF11R-M-DC24V
PM4HF11R-M-DC24VS
mm inch
Toletance: ±0.5 ±.020
Dimensions
• Screw terminal type (Flush mount)
Part number
14.5
.571
44.5
1.752
PM4H-F
Terminal layouts and Wiring diagrams
• PM4H-F8 (without reset input)
Pin type
Time-out 2 Form C
N.C.
N.C.
N.O.
4 5
3
2
(–)
• PM4H-F8R (with reset input)
Pin type
Time-out 1 Form C, with reset input
N.C.
N.O.
4 5
6
7
3
2
Reset
input
1 8
Operating voltage
• PM4H-F11R (with reset input)
Pin type
Time-out 2 Form C, with reset input
(+)
(–)
Screw-tightening pin type
The PM4H-F11R should be used for the timelimit 2C.
Reset input
N.O.
N.C.
N.C.
6
7
5 6 7
N.O.
4
3
2
1 8
Operating voltage
1 11
N.O.
8
9
10
Operating voltage
(+)
(–)
Screw-tightening pin type
The PM4H-F11R should be used for the timelimit 1C and to connect reset input.
(+)
Screw terminal type
Time-out 2 Form C, with reset input
N.C. N.O. 6
7
8
9
10
N.C. N.O.
11
1
(+)
2
3
Operating
voltage
4
5
Reset input
(–)
PM4H-F (with reset) input conditions
1. Contact input (pin type example)
PM4H-F8R
2. Non-contact input (pin type example)
PM4H-F11R
PM4H-F11R
Reset input
Reset input
PM4H-F8R
Use a contact with good contact reliability for the input. Contact bounce can
lead to erroneous operation of the
timer, so use a contact with short
bounce time. Make the resistance
between terminals for a short circuit
less than 1k-ohms. Make the resistance between terminals for an open
circuit greater than 100k-ohms.
Photo-coupler
Reset input
Reset input
Check that Vce = 0.6V
Max. when ON.
Photo-coupler
Operation
• PM4H-F8 (without reset input)
• PM4H-F8R/F11R (with reset input)
Note:
Tr
Tr
Note:
Ts
Tr
Ts
Power
supply
Power
supply
T
Time-delay
contact N.O.
Reset
input
Time-delay
contact N.C.
Time-delay
contact N.O.
T
Be sure to use a photocoupler for non-contact
input.
t
Time-delay
contact N.C.
t