0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PM4S-A2C30M-AC120V

PM4S-A2C30M-AC120V

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    ANALOG TIMER - PM4S

  • 数据手册
  • 价格&库存
PM4S-A2C30M-AC120V 数据手册
PM4S PM4S Timers MULTI-RANGE ANALOG TIMER Features RoHS Directive compatibility information http://www.nais-e.com/ 1. Economic pricing that promptly reflects market demands Remarkable economic pricing is implemented in pursuit of cost performance. 2. Output contacts switchable between timed out 2C and timed out 1C/Instantaneous 1C The timed out 1C/Instantaneous 1C output contact enables the efficient addition of self-maintenance circuits. 3. 4 different time ranges selectable on a single unit Five types of timers cover the full range of time settings from 1 second to 30 hours. 4. Equipped with zero-setting instantaneous output Set the dial all the way to “0” for instantaneous operation, so circuit testing can be easily accomplished. 5. Compliant with UL, c-UL and CE. Product types Type /////// Contact arrangement Time range PM4S Multi-range Timer A type 1s/10s/1min/10min (4 time ranges selectable) PM4S Multi-range Timer B type 3s/30s/3min/30min (4 time ranges selectable) PM4S Multi-range Ttimer C type Power ON-delay T.D.: Timed-out 2C INST.: Timed-out 1C Instantaneous 1C (Selected by front switch) 6s/60s/6min/60min (4 time ranges selectable) PM4S Multi-range Timer D type 1min/10min/1h/10h (4 time ranges selectable) PM4S Multi-range Timer E type 3min/30min/3h/30h (4 time ranges selectable) Operating voltage 100 to 120V AC 200 to 240V AC 12V DC 24V DC 100 to 120V AC 200 to 240V AC 12V DC 24V DC 100 to 120V AC 200 to 240V AC 12V DC 24V DC 100 to 120V AC 200 to 240V AC 12V DC 24V DC 100 to 120V AC 200 to 240V AC 12V DC 24V DC Parts name • The PM4S Multi-Range timer allows time units and output contacts to be selected via front switches. Output contact selector Time range selector Time unit selector All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. Part No. PM4S-A2C10M-AC120V PM4S-A2C10M-AC240V PM4S-A2C10M-DC12V PM4S-A2C10M-DC24V PM4S-A2C30M-AC120V PM4S-A2C30M-AC240V PM4S-A2C30M-DC12V PM4S-A2C30M-DC24V PM4S-A2C60M-AC120V PM4S-A2C60M-AC240V PM4S-A2C60M-DC12V PM4S-A2C60M-DC24V PM4S-A2C10H-AC120V PM4S-A2C10H-AC240V PM4S-A2C10H-DC12V PM4S-A2C10H-DC24V PM4S-A2C30H-AC120V PM4S-A2C30H-AC240V PM4S-A2C30H-DC12V PM4S-A2C30H-DC24V PM4S Specifications Type PM4S Multi-range Timer Item Rated operating voltage Rated frequency 100 to 120V AC Rated power consumption Output rating Operating mode Rating Time accuracy Note) A type B type Time range C type D type E type Operating time fluctuation Setting error Voltage error Temperature error Contact arrangement Contact Contact resistance (Initial value) Contact material Mechanical (contact) Electrical (contact) Allowable operating voltage range Life Insulation resistance (Initial value) Electrical function Breakdown voltage (Initial value) Min. power off time Max. temperature rise Functional Destructive Functional Destructive Vibration resistance Mechanical function Shock resistance Operating condition Others Ambient temperature Ambient humidity Atmospheric pressure Ripple factor (DC type) Weight 200 to 240V AC 12V DC 24V DC 50/60 Hz — Approx. 3.0VA/3.6VA Approx. 5.6VA/6.8VA (at 100V AC) (at 200V AC) Approx. 1.3W Approx. 1.7W Approx. 4.5VA/5.25VA Approx. 7.5VA/9.8VA (at 120V AC) (at 240V AC) 5A 250V AC (resistive load) Power ON-delay 1s/10s/1min/10min (4 time ranges selectable) 3s/30s/3min/30min (4 time ranges selectable) 6s/60s/6min/60min (4 time ranges selectable) 1min/10min/1h/10h (4 time ranges selectable) 3min/30min/3h/30h (4 time ranges selectable) ±1% (power off time change at the range of 0.1s to 1h) ±5% (Full-scale value) ±1% (at the operating voltage changes between 85 to 110%) ±2% (at 20°C ambient temp. at the range of –10 to +50°C +14 to +122°F) T.D.: Timed-out 2 Form C INST.: Timed-out 1 Form C, instantaneous 1 Form C (Selected by front switch) Max. 100mΩ (at 1A 6V DC) Silver alloy Min. 107 Min. 105 (at raed control capacity) 85 to 110% of rated operating voltage Min. 100MΩ Between live and dead metal parts (At 500V DC) Between input and output Between contacts of different poles Between contacts of same pole 2,000Vrms for 1 min Between live and dead metal parts 2,000Vrms for 1 min Between input and output 2,000Vrms for 1 min Between contacts of different poles 1,000Vrms for 1 min Between contacts of same pole 100 ms 55°C 131°F 10 to 55Hz: 1 cycle/min double amplitude of 0.25mm (10min on 3 axes) 10 to 55Hz: 1 cycle/min double amplitude of 0.375mm (1h on 3 axes) Min. 98m/s2 (4 times on 3 axes) Min. 980m/s2 (5 times on 3 axes) –10 to +50°C +14 to +122°F 30 to 85%RH (non-condensing) 860 to 1,060hPa 20% Approximately 110 g 3.880 oz Notes) 1. Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% ripple factor for DC), 20°C 68°F ambient temperature, and 1s power off time. 2. For the 1s range, the tolerance for each specification becomes ±10ms. Applicable standard Safety standard EN61812-1 (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity EMC Pollution Degree 2/Overvoltage Category III EN55011 Group1 ClassA EN55011 Group1 ClassA EN61000-4-2 RF electromagnetic field immunity EN61000-4-3 EFT/B immunity EN61000-4-4 Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/Instantaneous stop/Voltage fluctuation immunity EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 4 kV contact 8 kV air 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (895 MHz to 905 MHz) 2 kV (power supply line) 1 kV (power line) 10 V/m AM modulation (0.15 MHz to 80 MHz) 30 A/m (50 Hz) 10 ms, 30% (rated voltage) 100 ms, 60% (rated voltage) 1,000 ms, 60% (rated voltage) 5,000 ms, 95% (rated voltage) All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. PM4S Dimension (Unit: mm inch) Tolerance: ±0.5 ±.020 • Surface mount dimensions 14.5 .571 48 1.890 5.5 .217 63.7 2.508 102.2 4.024 14.2 .559 DIN rail terminal block AT8-DF8K (Sold separately) 44.5 1.752 • Panel mount dimensions (with mounting frame) Device installation rail AT8-DLA1 (Sold separately) • Panel cut out dimensions Standard cut out dimensions are shown below. Use mounting frame (AT8-DA4) and rubber gasket (ATC18002). Mounting frame AT8-DA4 (Sold separately) 45+0.6 0 1.772+.024 0 Min. 80 3.150 45+0.6 0 1.772+.024 0 50 1.969 Min. 80 3.150 • Adjacent mounting 84.7 3.335 Rear terminal socket AT78041 (Sold separately) Panel (Thickness 1 to 3.5 mm .039 to .138 inch) 45+0.6 0 1.772+.024 0 A A = (48×n–2.5)+0.6 0 A = (1.890×n–.098)+.024 0 • Terminal layouts and wiring diagrams NC T. D. I N S T. 3 4 NO 4 3 4 MODE 1 1 NC NO 5 3 6 2 7 1 8 COM T.D.: Timed-out 2 Form C INST.: Timed-out 1 Form C, instantaneous 1 Form C * Selected by front switch Notes: 1. Operating voltage signs in parentheses ( ) indicate the polarity of the DC type. COM 2. is a time delay contact. Operating voltage is an instantaneous contact. Operation mode 1. T.D. mode 2. INST. mode Power supply Time out (N.O. contact) 1–3 or 6–8 OP.LED OFF ON ON OFF T Power supply T ON OFF Time out (N.O. contact) 6–8 ON ON OFF OFF Time out (N.O. contact) 1–3 OP.LED All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. Note: Keep 0.1s or more for power off time. PM4S Precautions during usage 4. In order to maintain the characteristics, do not remove the timer case. 5. When installing the panel, use the ATA4811 mounting frame (Sold separately). 6. If you change the operating voltage, be sure not to allow leak current into the timer. 7. Avoid leaving the unit powered continuously. Leaving the unit powered up with output set to ON continuously for a long period of time (about 1 month or more) will wear out the electronic components. If you will be keeping it powered continuously, combine with a relay to create the circuit shown below: 1. Avoid locations subject to flammable or corrosive gases, excessive dust, oil, vibrations, or excessive shocks. 2. Since the main-unit is made of polycarbonate resin, avoid contact with or use in environments containing methyl alcohol, benzene, thinners, and other organic solvents; and ammonia, caustic sodas, and other alkaline substances. 3. Power supply superimposed surge protector Although a surge protector will withstand standard-waveform voltage with the values in the next table, anything above this will destroy the internal circuit. You should therefore use a surge absorber. 12 V DC 24 V DC 500 V 100 to 120 V AC 200 to 240 V AC 4,000 V R T R • Surge waveform [±(1.2×50) µs uni-polar full wave voltage] R 8. The timer setting dial should only be turned within the range indicated on the dial face. Turning it too far may break the stopper and cause damage to internal components. T Acquisition of CE marking Please abide by the conditions below when using in applications that comply with EN61812-1. 1. Overvoltage category III, pollution level 2 2. The load connected to the output contact should have basic insulation. This timer is protected with basic insulation and can be doubleinsulated to meet EN/IEC requirements by using basic insulation on the load. 3. Please use a power supply that is protected by an overcurrent protection device which complies with the EN/ IEC standard (example: 250 V 1 A fuse, etc.). 4. You must use a terminal socket or socket for the installation. Do not touch the terminals or other parts of the timer when it is powered. When installing or un-installing, make sure that no voltage is being applied to any of the terminals. 5. Do not use this timer as a safety circuit. For example when using a timer in a heater circuit, etc., provide a protection circuit on the machine side. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
PM4S-A2C30M-AC120V 价格&库存

很抱歉,暂时无法提供与“PM4S-A2C30M-AC120V”相匹配的价格&库存,您可以联系我们找货

免费人工找货