PQ1A-24V

PQ1A-24V

  • 厂商:

    NAIS(松下)

  • 封装:

    插件

  • 描述:

  • 数据手册
  • 价格&库存
PQ1A-24V 数据手册
1 Form A 5A small size power relay for interface RoHS compliant Protective construction: Sealed type PQ RELAYS FEATURES TYPICAL APPLICATIONS 1. Compact and slim 20 mm (L) × 10 mm (W) × 16 mm (H) .787 inch (L) × .394 inch (W) × .630 inch (H) slim type 2. Twin contact structure Gold-clad twin (bifurcated) contacts provide high reliability. 3. High capacity and small size This small package can provide high 5 A capacity. 4. High sensitivity with 200 mW nominal operating power 5. High surge breakdown voltage Despite the compact size, between contact and coil surge resistance of 8,000 V has been achieved. The relay has low susceptibility to noise. 6. Outstanding shock resistance Functional shock resistance: 294 m/s2 7. Sealed type 8. Sockets are available 1. Industrial equipment, office equipment 2. Measuring devices and test equipment 3. Interface relays for programmable controllers 4. Output relays in small devices such as timers, counters, sensors, and temperature controllers ORDERING INFORMATION PQ 1a Contact arrangement 1a: 1 Form A (Bifurcated) Nominal coil voltage (DC) 3, 5, 6, 9, 12, 18, 24 V Notes: 1. Certified by UL, CSA, VDE and SEMKO 2. TÜV approved type is available. TYPES Contact arrangement Nominal coil voltage Part No. 1 Form A (Bifurcated) 3V DC 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC PQ1a-3V PQ1a-5V PQ1a-6V PQ1a-9V PQ1a-12V PQ1a-18V PQ1a-24V Standard packing: Carton: 100 pcs.; Case: 500 pcs. * Sockets available. –1– ASCTB206E 201605-T PQ RATING 1. Coil data Nominal coil voltage Pick-up voltage (at 20°C 68°F) Nominal operating current [±10%] (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) Coil resistance [±10%] (at 20°C 68°F) 3V DC 66.7mA 45Ω 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 40mA 33.3mA 22.2mA 16.7mA 11.1mA 8.3mA 125Ω 180Ω 405Ω 720Ω 1,620Ω 2,880Ω 75%V or less of nominal voltage (Initial) 5%V or more of nominal voltage (Initial) Nominal operating power Max. applied voltage 180%V of nominal voltage (at 20°C 68°F) 200mW 130%V of nominal voltage (at 70°C 158°F) 2. Specifications Characteristics Item Arrangement Contact resistance (Initial) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (Reference value)*1 Insulation resistance (Initial) Contact Rating Breakdown voltage (Initial) Electrical characteristics Specifications 1 Form A (Bifurcated) Max. 50 mΩ (By voltage drop 6 V DC 1A) Au-clad AgNi type 5 A 250 V AC, 5 A 30 V DC 1,250 VA, 150 W 250 V AC, 110 V DC (0.3 A) 5A 200 mW 100μA 100mV DC Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section. Between open contacts Between contact and coil 1,000 Vrms for 1min. (Detection current: 10mA.) 4,000 Vrms for 1min. (Detection current: 10mA.) Surge breakdown Between contacts and coil voltage (Initial)*2 Operate time (at 20°C 68°F) (Initial) Release time (at 20°C 68°F) (Initial) Functional Destructive Functional Vibration resistance Destructive Mechanical Electrical (at 20 times/min.) Shock resistance Mechanical characteristics Expected life Conditions for operation, transport and storage*3 Conditions Max. operating speed (at rated load) Unit weight 8,000 V Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time.) Max. 10 ms (Nominal voltage applied to the coil, excluding contact bounce time.) (without diode) 294 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.) 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 2.0 mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 3.5 mm Min. 2×107 (at 180 times/min.) Min. 2×105 (5 A 125 V AC), Min. 105 (5 A 250 V AC), Min. 105 (5 A 30 V DC) Ambient temperature: –40°C to 70°C –40°F to 158°F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. Approx. 7 g .25 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. REFERENCE DATA 1. Max. switching capacity 2. Operate & release time 3. Coil temperature rise Tested sample: PQ1a-24V, 25 pcs. Measured portion: Inside the coil Contact carrying current: 5 A AC resistive load 5 1 DC resistive load 8 6 Operate time 4 Max. Min. Max. Min. 2 0.3 Release time 10 100 250 30 Contact voltage, V 1,000 0 80 100 120 150 Coil applied voltage, %V –2– Temperature rise,°C 10 70 Operate & release time, ms Contact current,A 100 60 50 50°C 40 30 20 70°C 10 0 100 110 120 130 140 150 160 Coil applied voltage,%V ASCTB206E 201605-T PQ 4. Ambient temperature characteristics Coil applied voltage, %V Tested sample: PQ1a-24V Contact carrying current: 5 A Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) 300 200 Pick-up voltage with a hot-start condition of 100%V on the coil 100 Pick-up voltage 0 20 40 60 80 100 Ambient temperature, °C DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ External dimensions CAD Data 10 .394 Schematic (Bottom view) COM 20 .787 N.O. Coil 15.6 .614 PC board pattern (Bottom view) 0.4 .016 7.62 .300 0.5 .020 4.2 .165 10.16 .400 7.62 .300 0.3 .012 0.3 .012 Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 5mm .197 inch: Min. 5mm .197 inch: 7.62 .300 10.16 .400 0.8 .031 7.62 .300 4-1.3 dia. 4-.051 dia. 7.62 .300 General tolerance ±0.2 ±.008 ±0.3 ±.012 ±0.4 ±.016 Tolerance: ±0.1 ±.004 SAFETY STANDARDS File No. E43028 UL (Recognized) Contact rating 5A 277V AC 1/6HP 277V AC 5A 30V DC 0.3A 110V DC File No. LR26550 CSA (Certified) Contact rating 5A 277V AC 1/6HP 277V AC 5A 30V DC 0.3A 110V DC File No. 40013088 VDE (Certified) Contact rating 5A 250V AC (cosφ =0.4) 5A 30V DC (0ms) — — Temp. 70°C 158°F 70°C 158°F — — Cycles 104 104 — — EN/IEC VDE Certified INSULATION CHARACTERISTIC (IEC61810-1) Item Clearance/Creepage distance (IEC61810-1) Category of protection (IEC61810-1) Tracking resistance (IEC60112) Insulation material group Over voltage category Rated voltage Pollution degree Type of insulation (Between contact and coil) Type of insulation (Between open contacts) Characteristic Min. 3.0mm/4.0mm RT III PTI 175 III a III 250V 3 Basic insulation Micro disconnection –3– ASCTB206E 201605-T PQ NOTES 1. For cautions for use, please read “GENERAL APPLICATION GUIDELINES”. Note about relay installation orientation Top When installing with the relay terminals parallel to the ground, the contact terminals at the bottom and the coil terminals at the top, component friction will occur after numerous switching actions or due to vibration in the non-excitation state. Since this may cause the relay to stop functioning when the pick-up voltage increases even if the nominal voltage is applied, please do not install using this orientation. Bottom –4– ASCTB206E 201605-T
PQ1A-24V 价格&库存

很抱歉,暂时无法提供与“PQ1A-24V”相匹配的价格&库存,您可以联系我们找货

免费人工找货