1 Form A 5A small size
power relay for interface
RoHS compliant
Protective construction: Sealed type
PQ RELAYS
FEATURES
TYPICAL APPLICATIONS
1. Compact and slim
20 mm (L) × 10 mm (W) × 16 mm (H)
.787 inch (L) × .394 inch (W) × .630 inch
(H) slim type
2. Twin contact structure
Gold-clad twin (bifurcated) contacts
provide high reliability.
3. High capacity and small size
This small package can provide high 5 A
capacity.
4. High sensitivity with 200 mW
nominal operating power
5. High surge breakdown voltage
Despite the compact size, between
contact and coil surge resistance of
8,000 V has been achieved. The relay
has low susceptibility to noise.
6. Outstanding shock resistance
Functional shock resistance: 294 m/s2
7. Sealed type
8. Sockets are available
1. Industrial equipment, office
equipment
2. Measuring devices and test
equipment
3. Interface relays for programmable
controllers
4. Output relays in small devices such
as timers, counters, sensors, and
temperature controllers
ORDERING INFORMATION
PQ 1a
Contact arrangement
1a: 1 Form A (Bifurcated)
Nominal coil voltage (DC)
3, 5, 6, 9, 12, 18, 24 V
Notes: 1. Certified by UL, CSA, VDE and SEMKO
2. TÜV approved type is available.
TYPES
Contact arrangement
Nominal coil voltage
Part No.
1 Form A
(Bifurcated)
3V DC
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
PQ1a-3V
PQ1a-5V
PQ1a-6V
PQ1a-9V
PQ1a-12V
PQ1a-18V
PQ1a-24V
Standard packing: Carton: 100 pcs.; Case: 500 pcs.
* Sockets available.
–1–
ASCTB206E 201605-T
PQ
RATING
1. Coil data
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
3V DC
66.7mA
45Ω
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
40mA
33.3mA
22.2mA
16.7mA
11.1mA
8.3mA
125Ω
180Ω
405Ω
720Ω
1,620Ω
2,880Ω
75%V or less of
nominal voltage
(Initial)
5%V or more of
nominal voltage
(Initial)
Nominal operating
power
Max. applied voltage
180%V of
nominal voltage
(at 20°C 68°F)
200mW
130%V of
nominal voltage
(at 70°C 158°F)
2. Specifications
Characteristics
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Contact
Rating
Breakdown voltage
(Initial)
Electrical
characteristics
Specifications
1 Form A (Bifurcated)
Max. 50 mΩ (By voltage drop 6 V DC 1A)
Au-clad AgNi type
5 A 250 V AC, 5 A 30 V DC
1,250 VA, 150 W
250 V AC, 110 V DC (0.3 A)
5A
200 mW
100μA 100mV DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Between open contacts
Between contact and coil
1,000 Vrms for 1min. (Detection current: 10mA.)
4,000 Vrms for 1min. (Detection current: 10mA.)
Surge breakdown
Between contacts and coil
voltage (Initial)*2
Operate time (at 20°C 68°F) (Initial)
Release time (at 20°C 68°F) (Initial)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Electrical (at 20 times/min.)
Shock resistance
Mechanical
characteristics
Expected life
Conditions for operation, transport and storage*3
Conditions
Max. operating speed (at rated load)
Unit weight
8,000 V
Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time.)
Max. 10 ms (Nominal voltage applied to the coil, excluding contact bounce time.)
(without diode)
294 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 2.0 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 3.5 mm
Min. 2×107 (at 180 times/min.)
Min. 2×105 (5 A 125 V AC), Min. 105 (5 A 250 V AC), Min. 105 (5 A 30 V DC)
Ambient temperature: –40°C to 70°C –40°F to 158°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min.
Approx. 7 g .25 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
1. Max. switching capacity
2. Operate & release time
3. Coil temperature rise
Tested sample: PQ1a-24V, 25 pcs.
Measured portion: Inside the coil
Contact carrying current: 5 A
AC resistive load
5
1
DC resistive load
8
6
Operate time
4
Max.
Min.
Max.
Min.
2
0.3
Release time
10
100 250
30
Contact voltage, V
1,000
0
80
100
120
150
Coil applied voltage, %V
–2–
Temperature rise,°C
10
70
Operate & release time, ms
Contact current,A
100
60
50
50°C
40
30
20
70°C
10
0
100
110 120 130
140 150
160
Coil applied voltage,%V
ASCTB206E 201605-T
PQ
4. Ambient temperature characteristics
Coil applied voltage, %V
Tested sample: PQ1a-24V
Contact carrying current: 5 A
Allowable ambient temperature
against % coil voltage (max.
inside the coil temperature set
as 115°C 239°F)
300
200
Pick-up voltage with a hot-start
condition of 100%V on the coil
100
Pick-up voltage
0
20
40
60
80
100
Ambient temperature, °C
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
CAD Data
10
.394
Schematic (Bottom view)
COM
20
.787
N.O.
Coil
15.6
.614
PC board pattern
(Bottom view)
0.4
.016
7.62
.300
0.5
.020
4.2
.165
10.16
.400
7.62
.300
0.3
.012
0.3
.012
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 5mm .197 inch:
Min. 5mm .197 inch:
7.62
.300
10.16
.400
0.8
.031
7.62
.300
4-1.3 dia.
4-.051 dia.
7.62
.300
General tolerance
±0.2 ±.008
±0.3 ±.012
±0.4 ±.016
Tolerance: ±0.1 ±.004
SAFETY STANDARDS
File No.
E43028
UL (Recognized)
Contact rating
5A 277V AC
1/6HP 277V AC
5A 30V DC
0.3A 110V DC
File No.
LR26550
CSA (Certified)
Contact rating
5A 277V AC
1/6HP 277V AC
5A 30V DC
0.3A 110V DC
File No.
40013088
VDE (Certified)
Contact rating
5A 250V AC (cosφ =0.4)
5A 30V DC (0ms)
—
—
Temp.
70°C 158°F
70°C 158°F
—
—
Cycles
104
104
—
—
EN/IEC VDE Certified
INSULATION CHARACTERISTIC (IEC61810-1)
Item
Clearance/Creepage distance (IEC61810-1)
Category of protection (IEC61810-1)
Tracking resistance (IEC60112)
Insulation material group
Over voltage category
Rated voltage
Pollution degree
Type of insulation (Between contact and coil)
Type of insulation (Between open contacts)
Characteristic
Min. 3.0mm/4.0mm
RT III
PTI 175
III a
III
250V
3
Basic insulation
Micro disconnection
–3–
ASCTB206E 201605-T
PQ
NOTES
1. For cautions for use, please read “GENERAL APPLICATION GUIDELINES”.
Note about relay installation orientation
Top
When installing with the relay terminals parallel to the ground, the contact terminals at
the bottom and the coil terminals at the top, component friction will occur after
numerous switching actions or due to vibration in the non-excitation state.
Since this may cause the relay to stop functioning when the pick-up voltage increases
even if the nominal voltage is applied, please do not install using this orientation.
Bottom
–4–
ASCTB206E 201605-T