0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
RF-SFBH-12

RF-SFBH-12

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    CORNER MIRROR 236 X 72 MM

  • 数据手册
  • 价格&库存
RF-SFBH-12 数据手册
Type 4 PLe SIL3 LIGHT CURTAIN SF4B SERIES Ver.2 Conforming to Machine & EMC Directive Certified Certified (SF4B-� only) Protection structure IP67 New version with improved environmental resistance performance Robust type SF4B-□G□ 2015.04 panasonic.net/id/pidsx/global Approved Listing Conforming to OSHA / ANSI (SF4B-�-03 only) (Excluding SF4B-�-03) GB Conforming to 4584 Advanced light curtains at the forefront of the industry Protection structure IP67 in a very compact size Improved environmental resistance performance and easier operability New structure A seamless structure with minimal joints has now been developed. The inner unit is protected by a cylindrical inner case. Seams on the unit and lens surfaces have been greatly reduced so that particles such as oil mists and dust are prevented from penetrating the case. Thus, the environmental resistance performance could be raised. SF4B series has passed the tests of IP65 and IP67 as specified by IEC / JIS standards. (Ver.2 only) IEC / JIS Description IP65 No harmful effect from direct water jet from any direction IP67 No water penetration from immersion in water under specified conditions * Refer to each standard for details of test conditions. Inner case Cylindrical inner case protects the internal unit. This new structure does not use adhesive or double-sided tape on the joints like the previous models. There is no need to worry about water immersion or corrosion such as a coolant causing the adhesive to strip off. Error details can be understood at a glance Equipped with a digital error indicator The system constantly checks the light curtain for problems such as incorrect cable wiring, disconnection, short-circuits, internal circuit problems, and incoming light problems. Details of any electrical problems such as at equipment startup will appear on the digital display. It is no longer necessary to count the number of times the LED blinks, making the system much more convenient. Angle of view is wider and indicators are even more visible Error number notification means smooth support via telephone Normal operation Digital error indicator 2 Error occurred Slim 28 mm 1.102 in Unified response time for all models A fast response time of 14 ms has been achieved regardless of the number of beam channels, the beam axis pitches and the number of units connected in series. This reduces calculation work required for the safety distance. 14 ms even in case of 3 units connected in series! Safety distance Safety distance (Note) Same response Characteristic distance for time of 14 ms the machinery’s maximum stopping time Finger protection type Hand protection type 28 mm* 1.102 in or * Series connection allows max. 3 sets or a total of up to 192 beam axes. 116 mm*4.567 in Dangerous source Safety distance Characteristic distance for light curtain Characteristic distance for the machinery’s maximum stopping time SF4B series Characteristic distance for SF4B series * This is the characteristic safety distance for the light curtain as defined by ISO 13855. Note: Calculate the safety distance based on the distance depending on the light curtain and the distance depending on the maximum halting time of machinery. For more details, refer to p.31~. Install the light curtain according to the relevant standards of the region where the light curtain is used. 3 A universal design that can be used anywhere in the world In Europe, America and Japan PNP output and NPN output in a single model! Supports both PNP and NPN polarities in a single model The SF4B series combines PNP transistor output and NPN transistor output in a single model. Overseas equipment that uses PNP, replacement with NPN sensors, factories that are positively grounded, and transfer of equipment overseas are all situations where the control circuits for a single model are suitable for use worldwide. ■ Polarity can be changed easily by changing wiring When the output polarity setting wire (shielded) is connected to 0 V, PNP output is selected, and when it is connected to 24 V, it switches to NPN output. PNP circuit 0V Output polarity setting wire (Shield) NPN circuit 24 V Output polarity setting wire (Shield) Control output (OSSD) Connect to 0 V Connect to 24 V Not connected / open PNP output NPN output Error PNP / NPN polarity indicator Either PNP or NPN side lights depending on which is selected. Global support for the safety of press machines or shear (paper cutting) machines Can be widely used for press machines and other types of equipment from Japan, Europe, North America, South Korea, and China. ●: Available Type Machinery EMC UL Japanese Press Japanese Shear S-mark Korean Press / Chinese GB Directive Directive Certified Machine Support (Paper Cutter) Support certification Cutting Machine Compatibility Model No. SF4B-□ SF4B-□G SF4B-A□-01 Light SF4B-H□-01 curtains SF4B-H□G-01 SF4B-F□-01 SF4B-□-03 ● ● ● ● ● ● ● ● ● (No.TA523) ● (No.TA521) ● ● ● ● ● ● ● (No.TA524) ● (No.TA522) ● ● ● ● SF-C11 ● ● ● SF-C12 ● ● ● SF-C13 ● ● ● ● ● ● ● ● ● Control SF-C14EX units SF-C14EX-01 ● ● (No.09-AV4BI-0001~0009) ● (No.TA525) (Note1) ● (No.TA526) (Note2) ● ● (No.TA527) (Note1) ● (No.TA528) (Note2) ● ● (No.TA529) (Note1) ● (No.TA530) (Note2) Notes: 1) In combination with SF4B-A□-01. (For products produced in or after October 2012)    2) In combination with SF4B-H□-01 / SF4B-H□G-01 / SF4B-F□-01. (For products produced in or after October 2012) It is possible to select from among each three types of standard / robust types depending on the worksite A wide range of variations are available with protective heights of 230 to 1,910 mm 9.055 to 75.197 in (1,270 mm 50.000 in for the finger protection type). Mixing six types in a series connection is also possible. Finger protection type SF4B-F□(G) SF4B-H□(G) Arm / foot protection type SF4B-A□(G) Minimum sensing object Minimum sensing object mm mm ø0.551 in mm mm ø0.984 in mm mm ø1.772 in ø14 (10 mm 0.394 in beam pitch) 4 Hand protection type Minimum sensing object ø25 (20 mm 0.787 in beam pitch) ø45 (40 mm 1.575 in beam pitch) Muting control function is built into light curtain Safety circuits are selectable A muting control function is provided to increase both safety and productivity (excluding SF4B-□-03) The light curtain is equipped with a muting control function that causes the line to stop only when a person passes through the light curtain, and does not stop the line when an object passes through. The muting sensors and muting lamps can be connected directly to the light curtain so that a exclusive controller is not required for muting. This both reduces costs and increases safety and productivity. Muting sensors Muting lamps Muting lamps Light curtain SF4B series SF4B series External device (Force-guided relay, etc.) Muting sensors CX-400 series Motor, etc. Override function allows the line to be restarted smoothly after it has stopped while muting control was active In case the power turns off while the light curtain has been interrupted by an object or in case the line stops before the muting conditions have been established (if only one muting sensor has been interrupted), the line can be restarted smoothly without having to remove the object that is interrupting the light curtain. (excluding SF4B-□-03) Example : When power turns off while light curtain was interrupted SF4B series Previous model Removal operation required No removal necessary Object must be removed before restart Smooth restart Equipped with a safety circuit that does not require an exclusive safety relay unit The light curtain has a built-in external device monitoring function (such as for monitoring whether relays have fused) and an interlock function. The safety circuit is built without safety relay unit and size reduction of a control board is achieved, which contributes to cost reduction. Previous model Reset input Monitor Light curtain Safety relay unit External devices (Force-guided relay, etc.) Motor, etc. SF4B series Reset input No safety relay unit needed Smaller control board Monitor SF4B series Built-in external device monitoring function External devices (Force-guided relay, etc.) Motor, etc. ●Recommended safety relay Panasonic Corporation SF relay slim type SF relay slim type SFS3-L-DC24V (AG1S132) SFS4-L-DC24V (AG1S142) DIN terminal block SFS4-SFD (AG1S847) [4-pole type] SFS6-SFD (AG1S867) [6-pole type] Note: C  ontact Panasonic Corporation for details on the recommended products. 5 A commitment to design that is easy to use Beam-axis alignment indicators show the incident light position at a glance Beam-axis alignment indicators display the beam channels of the light curtain in four blocks. When the beam channel at the bottommost channel (or topmost channel), which is used as a reference for beam-axis alignments, is correctly aligned, the LED blinks red. After this, each block lights red as the beam axes successively become aligned. When all channel beam axes are aligned, all LEDs light green. The display also has an additional stability indicator (STB) so that setup can be carried out with greater stability. The bottommost beam axis is aligned The beam axes of the two lower blocks are aligned All beam axes are aligned 4 block Beam axes are displayed in 4 blocks 3 block Blinking OSSD STB 1 block OSSD STB A B C D A B C D Light up OSSD STB Light up Light up OSSD STB 2 block A B C D A B C D The bottommost LED ‘D’ is blinking red The two bottom LEDs ‘C, D’ light up in red All LEDs ‘A to D’ light up in green Furthermore, STB display allows the most stable incident light status* to be confirmed. * 140 % or more incident light intensity of control output operation level Laser alignment tool for easy installation Greatly improved ease of installation (excluding SF4B-□G□) The tool performs beam-axis alignment using a laser beam spot. As the tool is battery-operated, it is possible to perform beam-axis alignment before supplying power to the equipment. The hexagon-socket head bolts used for aligning the beam axis can be accessed from the front of the light curtain. Beam adjustment can be carried out easily while turning the 360° rotation Hexagon-socket bolts. Also, when used with M5 hexagon-socket head bolt for beam-axis the beam-axis head bolt for alignment alignment (up to ±15˚) alignment part is directly and firmly fixed with M5 bolts so that beam axes Hexagon-socket misalignment head bolt for alignment can be (360˚ rotation for every 30˚) prevented. Laser alignment tool The topmost beam axis is correctly aligned Visible red spot! Mode Made of die-cast! Align at the front! Direct fixing to prevent misalignment! Few number of bolts! Hexagonal wrench The bottommost channel beam axis is correctly aligned Easy to distinguish receiver and emitter Emitter is gray, receiver is black. Whether during startup or maintenance, troubles due to incorrect wiring or false recognition can be greatly reduced. Moreover, the model No. can be checked at the front face of the light curtain. Black connector Gray cable with black line Black cover Receiver Model No. is shown on the front face of the sensor Emitter SF-4B-00�V2� EMITTER Type4 Gray connector 6 RECEIVER SF-4B-00�V2� RECEILVER Type4 Gray cable Gray cover EMITTER Mutual interference is reduced without needing interference prevention lines Reducing the number of malfunctions caused by extraneous light The light curtain is equipped with the ELCA (Extraneous Light Check & Avoid) function. Because it automatically shifts the scan timing of the light curtain in order to avoid interference, it is not necessary to wire interference prevention lines between machineries. Double scanning method and retry processing are two new functions exclusive to our company, which successfully eliminate the effects of momentary extraneous light from peripheral equipment. The reduction in operating errors caused by extraneous light reduces frequent stopping of machinery. Options exclusive for light curtain are available for an easy construction of safety circuit Handy-controller SFB-HC* that enables the user to select a variety of settings SFB-HC Separate muting control function for each beam channel The handy-controller SFB-HC* (optional) can be used to carry out muting control for specified beam axes only. Because individual beam axis can be specified to suit the object, separate guards to prevent entry do not need to be set up. While muting control is active (line operating) Line stopped SFB-HC For example, depending on the height of the object, the muting function can be activated for 10 beam channels starting from the bottom, so that if the 11th or subsequent beam channels are interrupted, it is judged that a person has entered the area and the line stops. * A handy-controller cannot be used with the SF4B-□-01, SF4B-H□G-01, SF4B-□-03 and the SF-C14EX-01. Specific beam axes can be deactivated The SF4B series incorporates a fixed blanking function. A variable number of beam axes can be deactivated The SF4B series incorporates a floating blanking function. The SF4B series is equipped with a fixed blanking function which allows specific beam channels to be selectively interrupted without causing the control output (OSSD) to output the OFF signal. This function is convenient for use with applications in which certain fixed obstacles tend to block specific beam channels. Furthermore, this function provides greater safety as the control output (OSSD) will automatically output the OFF signal if the fixed obstacles are subsequently removed from the sensing area. 1, 2 or 3 non-specified beam channels can be deactivated. If the number of beam channels that are blocked is less than or equal to the set number of beam channels, then the control output (OSSD) will not output the OFF signal. This function is useful when the positions of obstacles within the sensing area must be changed during object rearrangement, or when an object passes through the light curtain’s sensing area. Note: When the floating blanking function is used, the acceptable size for the minimum sensing object changes. Refer to “PRECAUTIONS FOR PROPER USE” (p.30) for details. Selectable configuration for auxiliary output Mode No. Description 0 1 2 3 4 5 6 7 8 9 Negative logic of the control output (OSSD 1, OSSD 2) (factory setting) Positive logic of the control output (OSSD 1, OSSD 2) For emission: output ON, For non-emission: output OFF For emission: output OFF, For non-emission: output ON For unstable incident beam: OFF (Note 1) For unstable incident beam: ON (Note 1) For muting: ON For muting: OFF For beam received: ON, For beam interrupted: OFF (Note 2) For beam received: OFF, For beam interrupted: ON (Note 2) Notes: 1) The output cannot be used while the fixed blanking function, floating blanking function or the muting function is activated. 2) This device outputs the beam received / interrupted state at the detectable area regardless of fixed blanking function, floating blanking function, and muting function. A variety of other functions can be selected Emission intensity control function This function reduces the amount of emitting light. The two modes, normal mode and short mode, can be selected (factory setting: normal mode). Monitoring function This function allows the user to confirm the details of each light curtain setting. Protection function A password protection can be used to avoid unauthorized changes of the settings (factory setting: no password protection). Copy function Setting details can be copied to other light curtains. This is helpful if you need the same settings on different devices. Muting lamp diagnosis setting When the muting lamp diagnosis is disabled, the muting function will continue to operate even if the lamp is blown. Refer to the SF4B manual for details. 7 Resistant to impact, less damage to workpiece Robust type SF4B-□G□ Thick and robust housing resistant to impact Front protection cover The SF4B-□G□ light curtain is enclosed in a 5 mm (0.197 in) thick robust metal case, protecting the workpiece from various types of impact, such as collision or being stepped on. The front protection cover protects the sensing surface from welding spatter and reduces damage due to collisions. The beam axis adjuster can be attached without removing the front protection cover. Average thickness 5 mm Stepped on Kicked Collision Impact Front protection cover 0.197 in Loads applied Dropped No guard needed Fully protected sensing surface The robust light curtain can be used without an L-shape or U-shape guard, reducing installation and maintenance. The sensing surface is fully protected by narrowing and deepening the exposed area of the sensing surface. Previous product SF4B-□G□ Collision with sensing surface Narrow Sensing surface protected Deep U-shape / L-shape guard Round design minimizes damage to the workpiece Enables series connection with standard type possible The case is designed so that shock upon impact is dissipated alleviating potential damage to the workpiece in the event of a collision. The mating cable is standard, allowing the robust and standard types to be connected in series. Previous product SF4B-□G□ Large impact on collision Small impact on collision Standard type Robust type Standard type Use robust type only for required sections Workpiece not contaminated with paint The body has an alumite-treated case so that paint does not stick to the workpiece in the event of a collision. PRODUCT CONFIGURATION Mounting bracket and mating cable are optional. Muting control components (12-core cable, with interference prevention wire) Standard components (8-core cable) Component parts Component parts 1 Light curtain Required 7 1 Light curtain 2 Mounting bracket (Optional) Required 7 3 8-core bottom cap cable (Optional) 6 12-core extension cable 7 Cable for series connection 7 Cable for series connection 2 8 (Optional, use for cable extension) 1 (Optional, use for connection in series) 3 5 12-core bottom cap cable (Optional) 4 8-core extension cable (Optional, use for cable extension) 1 2 Mounting bracket (Optional) 4 (Optional, use for connection in series) 5 2 6 ORDER GUIDE 1 Light curtains Mounting bracket and bottom cap cable are not supplied with the light curtain. Be sure to order them separately. Finger protection type Hand protection type Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) Min. sensing object ø14 mm ø0.551 in (10 mm 0.394 in beam pitch) Type Appearance Beam channel No. Number Protective height (mm in) of SFB-HC Korean Press compliant beam China Press compliant non‑compatible (SFB-HC non-ompatible) channels (GB4584)(Note 3) 23 230 9.055 220 8.661 SF4B-F23 SF4B-F23-01 SF4B-F23-03 Model No. (Note 2) Operating range (Note 1) 5 mm 0.197 in Protective height 0.3 to 7 m 0.984 to 22.966 ft Beam pitch 5 mm 10 mm 0.197 in 0.394 in Beam channel No. 5 mm 0.197 in 0.3 to 9 m 0.984 to 29.528 ft Protective height Beam pitch 5 mm 20 mm 0.197 in 0.787 in Arm / Foot protection type Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch) 0.3 to 7 m 0.984 to 22.966 ft Beam channel No. 15 mm 0.591 in 0.3 to 9 m 0.984 to 29.528 ft Protective height Beam pitch 40 mm 1.575 in 15 mm 0.591 in 0.3 to 7 m 0.984 to 22.966 ft SF4B-F31 SF4B-F31-01 SF4B-F31-03 31 310 12.205 300 11.811 SF4B-F39 SF4B-F39-01 SF4B-F39-03 39 390 15.354 380 14.960 SF4B-F47 SF4B-F47-01 SF4B-F47-03 47 470 18.504 460 18.110 SF4B-F55 SF4B-F55-01 SF4B-F55-03 55 550 21.654 540 21.260 SF4B-F63 SF4B-F63-01 SF4B-F63-03 63 630 24.803 620 24.409 SF4B-F71 SF4B-F71-01 SF4B-F71-03 71 710 27.953 700 27.559 SF4B-F79 SF4B-F79-01 SF4B-F79-03 79 790 31.102 780 30.708 SF4B-F95 SF4B-F95-01 SF4B-F95-03 95 950 37.402 940 37.007 SF4B-F111 SF4B-F111-01 SF4B-F111-03 111 1,110 43.701 1,100 43.306 SF4B-F127 SF4B-F127-01 SF4B-F127-03 127 1,270 50.000 1,260 49.606 SF4B-H12 SF4B-H12-01 SF4B-H12-03 12 230 SF4B-H16 SF4B-H16-01 SF4B-H16-03 16 310 12.205 300 11.811 SF4B-H20 SF4B-H20-01 SF4B-H20-03 20 390 15.354 380 14.960 SF4B-H24 SF4B-H24-01 SF4B-H24-03 24 470 18.504 460 18.110 SF4B-H28 SF4B-H28-01 SF4B-H28-03 28 550 21.654 540 21.260 SF4B-H32 SF4B-H32-01 SF4B-H32-03 32 630 24.803 620 24.409 SF4B-H36 SF4B-H36-01 SF4B-H36-03 36 710 27.953 700 27.559 SF4B-H40 SF4B-H40-01 SF4B-H40-03 40 790 31.102 780 30.708 SF4B-H48 SF4B-H48-01 SF4B-H48-03 48 950 37.402 940 37.007 SF4B-H56 SF4B-H56-01 SF4B-H56-03 56 1,110 43.701 1,100 43.306 SF4B-H64 SF4B-H64-01 SF4B-H64-03 64 1,270 50.000 1,260 49.606 SF4B-H72 SF4B-H72-01 SF4B-H72-03 72 1,430 56.299 1,420 55.905 SF4B-H80 SF4B-H80-01 SF4B-H80-03 80 1,590 62.598 1,580 62.205 SF4B-H88 SF4B-H88-01 SF4B-H88-03 88 1,750 68.898 1,740 68.503 SF4B-H96 SF4B-H96-01 SF4B-H96-03 96 1,910 75.197 1,900 74.803 SF4B-A6 SF4B-A6-01 – 6 230 SF4B-A8 SF4B-A8-01 – 8 310 12.205 280 11.024 SF4B-A10 SF4B-A10-01 – 10 390 15.354 360 14.173 SF4B-A12 SF4B-A12-01 – 12 470 18.504 440 17.323 SF4B-A14 SF4B-A14-01 – 14 550 21.654 520 20.472 SF4B-A16 SF4B-A16-01 – 16 630 24.803 600 23.622 SF4B-A18 SF4B-A18-01 – 18 710 27.953 680 26.772 SF4B-A20 SF4B-A20-01 – 20 790 31.102 760 29.921 SF4B-A24 SF4B-A24-01 – 24 950 37.402 920 36.220 SF4B-A28 SF4B-A28-01 – 28 1,110 43.701 1,080 42.520 SF4B-A32 SF4B-A32-01 – 32 1,270 50.000 1,240 48.819 SF4B-A36 SF4B-A36-01 – 36 1,430 56.299 1,400 55.118 SF4B-A40 SF4B-A40-01 – 40 1,590 62.598 1,560 61.417 SF4B-A44 SF4B-A44-01 – 44 1,750 68.898 1,720 67.716 SF4B-A48 SF4B-A48-01 – 48 1,910 75.197 1,880 74.016 9.055 9.055 220 200 8.661 7.874 Notes: 1) The operating range is the possible setting distance between the emitter and the receiver. The light curtain can detect an object less than 0.3 m 0.984 ft away. Receiver cannot be placed in this range Emitter 0.3 m 0.984 ft Actual operating range of the light curtain Receiver Setting range of the receiver 9 m 29.528 ft SF4B-F□, SF4B-H72/H80/H88/H96□, SF4B-A36/A40/A44/A48□, SF4B-F□G, SF4B-H72G/H80G/H88G/H96G□, SF4B-A36G/A40G/A44G/A48G: 7 m 22.966 ft Receiver 2) The model No. with “E” on the product label is the emitter, “D” on the label is the receiver. 3) Not conforming to Korean Press (SF4B-□-03) 9 ORDER GUIDE 1 Light curtains (Robust type) Mounting bracket and bottom cap cable are not supplied with the light curtain. Be sure to order them separately. Finger protection type Hand protection type Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) Min. sensing object ø14 mm ø0.551 in (10 mm 0.394 in beam pitch) Type Appearance Beam channel No. Operating range 11.8 mm 0.465 in Protective height 0.3 to 7 m 0.984 to 22.966 ft Beam pitch 11.8 mm 10 mm 0.465 in 0.394 in Beam channel No. 11.8 mm 0.465 in Protective height 0.3 to 9 m 0.984 to 29.529 ft Beam pitch 11.8 mm 20 mm 0.465 in 0.787 in Arm / Foot protection type Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch) 0.3 to 7 m 0.984 to 22.966 ft Beam channel No. 21.8 mm 0.858 in Protective height 0.3 to 9 m 0.984 to 29.529 ft Beam pitch 40 mm 1.575 in 21.8 mm 0.858 in 0.3 to 7 m 0.984 to 22.966 ft Differences from standard type Model No. SFB-HC non‑compatible Protective height (mm in) China Press compliant (GB4584) SF4B-F23G – 23 244 9.606 220 SF4B-F31G – 31 324 12.756 300 11.811 SF4B-F39G – 39 404 15.906 380 14.960 SF4B-F47G – 47 484 19.055 460 18.110 SF4B-F55G – 55 564 22.205 540 21.260 SF4B-F63G – 63 644 25.354 620 24.409 SF4B-F71G – 71 724 28.504 700 27.559 SF4B-F79G – 79 804 31.654 780 30.708 SF4B-F95G – 95 964 37.953 940 37.007 SF4B-F111G – 111 1,124 44.252 1,100 43.306 SF4B-F127G – 127 1,284 50.551 1,260 49.606 SF4B-H12G SF4B-H12G-01 12 244 9.606 220 SF4B-H16G SF4B-H16G-01 16 324 12.756 300 11.811 SF4B-H20G SF4B-H20G-01 20 404 15.906 380 14.960 SF4B-H24G SF4B-H24G-01 24 484 19.055 460 18.110 SF4B-H28G SF4B-H28G-01 28 564 22.205 540 21.260 SF4B-H32G SF4B-H32G-01 32 644 25.354 620 24.409 SF4B-H36G SF4B-H36G-01 36 724 28.504 700 27.559 SF4B-H40G SF4B-H40G-01 40 804 31.654 780 30.708 SF4B-H48G SF4B-H48G-01 48 964 37.953 940 37.007 SF4B-H56G SF4B-H56G-01 56 1,124 44.252 1,100 43.306 SF4B-H64G SF4B-H64G-01 64 1,284 50.551 1,260 49.606 SF4B-H72G SF4B-H72G-01 72 1,444 56.850 1,420 55.905 SF4B-H80G SF4B-H80G-01 80 1,604 63.150 1,580 62.205 SF4B-H88G SF4B-H88G-01 88 1,764 69.449 1,740 68.503 SF4B-H96G SF4B-H96G-01 96 1,924 75.748 1,900 74.803 SF4B-A6G – 6 244 9.606 200 280 11.024 8.661 8.661 7.874 SF4B-A8G – 8 324 12.756 SF4B-A10G – 10 404 15.906 360 14.173 SF4B-A12G – 12 484 19.055 440 17.323 SF4B-A14G – 14 564 22.205 520 20.472 SF4B-A16G – 16 644 25.354 600 23.622 SF4B-A18G – 18 724 28.504 680 26.772 SF4B-A20G – 20 804 31.654 760 29.921 SF4B-A24G – 24 964 37.953 920 36.220 SF4B-A28G – 28 1,124 44.252 1,080 42.520 SF4B-A32G – 32 1,284 50.551 1,240 48.819 SF4B-A36G – 36 1,444 56.850 1,400 55.118 SF4B-A40G – 40 1,604 63.150 1,560 61.417 SF4B-A44G – 44 1,764 69.449 1,720 67.716 SF4B-A48G – 48 1,924 75.748 1,880 74.016 The robust type SF4B-□G□ is different from the standard type SF4B-□ in the following ways: • Sensing width (protective height) • Profile • Net weight • Mounting bracket • Front protection cover • Laser alignment tool • Noncompliant with Japanese and Korean press standard • Noncompliant with Korean regulations Other specifications, input/output circuits, and options are the same as for the standard type. 10 Number of beam channels ORDER GUIDE 2 Mounting brackets Mounting bracket is not supplied with the light curtain. Be sure to order it separately. Designation Model No. Description M8 rear mounting bracket MS-SFB-7-T For rear mounting. Allows the light curtain to be mounted at the rear with one M8 hexagon-socket-head bolt. (4 pcs. per set for emitter and receiver) M8 side mounting bracket MS-SFB-8-T For side mounting. Allows the light curtain to be mounted at the side with one M8 hexagon-socket-head bolt. (4 pcs. per set for emitter and receiver) M8 rear / side mounting bracket set MS-SFB-1-T2 Can be used as either a rear mounting bracket MS-SFB-7-T or a side mounting bracket MS-SFB-8-T depending on mounting direction. (4 pcs. per set for emitter and receiver) Standard mounting bracket MS-SFB-1 Used to mount the light curtain on the rear surface and side surface. (4 pcs. per set for emitter and receiver) MS-SFB-1-T Allows the light curtain to be mounted at the rear and side with one M8 hexagonsocket-head bolt. (4 pcs. per set for emitter and receiver) MS-SFB-4 Used as the mounting bracket when changing over a previous light curtain with a protective height of 200 mm 7.874 in or more to the SF4B series. It is installed using two M5 hexagon-socket-head bolts. (4 pcs. per set for emitter and receiver) MS-SFB-4-T Used as the mounting bracket when changing over a previous light curtain with a protective height of 200 mm 7.874 in or more to the SF4B series. It is installed using one M8 hexagon-socket-head bolt. (4 pcs. per set for emitter and receiver) Dead zoneless mounting bracket (Material: Die-cast zinc alloy) MS-SFB-3 Mounting with no dead zone is possible so that the mounting bracket does not project past the protective height. (4 pcs. per set for emitter and receiver) Standard L mounting bracket (For SF4B-□G□) Material: Cold rolled carbon steel (SPCC) (Trivalent chrome plated) MS-SF4BG-1 Mounting is possible behind or at the side of the light curtain. Mount with two M5 bolts or one M8 bolt. (4 pcs. per set for emitter and receiver) Dead zoneless mounting bracket (For SF4B-□G□) Material: Mounting bracket ... Cold rolled carbon steel (SPCC) (Trivalent chrome plated) Supporting bracket ...PPS MS-SF4BG-3 Allows light curtains to be installed closely together or in locations with installation restrictions due to equipment columns or jigs. (4 pcs. per set for emitter and receiver) Rear / side mounting bracket Material: Cold rolled carbon steel (SPCC) 360° mounting bracket Material: Die-cast zinc alloy M8 mounting bracket Pitch adapter bracket * Light curtain can revolve 360° horizontally. M8 pitch adapter bracket M8 rear mounting bracket M8 side mounting bracket Standard mounting bracket M8 mounting bracket Pitch adapter bracket • MS-SFB-7-T • MS-SFB-1-T2 (Rear mounting) • MS-SFB-1 • MS-SFB-8-T • MS-SFB-1-T2 (Side mounting) M8 rear mounting bracket MS-SFB-7-T MS-SFB-1-T2 (Rear mounting) M5 (length: 18 mm 0.709 in) hexagon-socket-head bolt Accessory for MS-SFB-7-T MS-SFB-1-T2 ( ) Light curtain M5 (length: 18 mm 0.709 in) hexagon-socket-head bolt Accessory for MS-SFB-8-T MS-SFB-1-T2 ( ) Sensing surface Four bracket set Four M5 (length: 18 mm 0.709 in) hexagon-socket-head bolts are attached. M8 mounting hole (for center mounting) Standard mounting bracket MS-SFB-1 M8 side mounting bracket MS-SFB-8-T MS-SFB-1-T2 (Side mounting) M5 mounting hole (for two-point mounting) Light curtain Sensing surface Four bracket set Four M5 (length: 18 mm 0.709 in) hexagon-socket-head bolts are attached. M8 pitch adapter bracket Dead zoneless mounting bracket • MS-SFB-4-T • MS-SFB-3 M8 pitch adapter bracket MS-SFB-4-T M5 (length: 18 mm 0.709 in) hexagon-socket-head bolt (Accessory for MS-SFB-4-T) Light curtain Sensing surface Four bracket set Four M5 (length: 18 mm 0.709 in) hexagon-socket-head bolts are attached. Light curtain Light curtain Sensing surface Four bracket set Four M5 (length: 25 mm 0.984 in) hexagon-socket-head bolts and four spacers are attached. M5 (length: 18 mm 0.709 in) hexagon-socket-head bolt (Accessory for MS-SFB-1) Sensing surface Four bracket set Four M5 (length: 18 mm 0.709 in) hexagon-socket-head bolts are attached. M5 (length: 18 mm 0.709 in) hexagon-socket-head bolt (Accessory for MS-SFB-1-T) • MS-SF4BG-1 M5 (length: 10 mm 0.394 in) hexagon-socket-head bolt (Accessory) M5 mounting hole Standard L mounting bracket (MS-SF4BG-1) M8 mounting hole (For mounting in center) Light curtain Four bracket set Eight M5 (length: 10 mm 0.394 in) hexagon-socket-head bolts are attached. M8 mounting bracket MS-SFB-1-T Light curtain Sensing surface Standard L mounting bracket (For SF4B-□G□) Dead zoneless mounting bracket MS-SFB-3 Spacer (Accessory for MS-SFB-3) M5 (length: 25 mm 0.984 in) hexagon-socket-head bolt (Accessory for MS-SFB-3) • MS-SFB-4 • MS-SFB-1-T Four bracket set Four M5 (length: 18 mm 0.709 in) hexagon-socket-head bolts are attached. Pitch adapter bracket MS-SFB-4 M5 (length: 18 mm 0.709 in) hexagon-socket-head bolt (Accessory for MS-SFB-4) Light curtain Sensing surface Four bracket set Four M5 (length: 18 mm 0.709 in) hexagon-socket-head bolts are attached. Dead zoneless mounting bracket (For SF4B-□G□) • MS-SF4BG-3 When using M5 hexagon- When using M8 socket-head bolt hexagon bolt (Rear mounting) (Rear mounting) M5 hexagonsocket-head bolt (Parchase separately.) Light curtain Dead zoneless supporting bracket Accessory for dead zoneless mounting bracket Dead zoneless mounting bracket MS-SF4BG-3 M8 hexagon bolt (Parchase separately.) Light curtain Dead zoneless supporting bracket Accessory for dead zoneless mounting bracket Dead zoneless mounting bracket MS-SF4BG-3 Four bracket set Twelve M5 (length: 8 mm 0.315 in) hexagon-socket-head bolts and four nut slots are attached. 11 ORDER GUIDE 3 4 5 6 Discrete wire Bottom cap cable Connector 3 For emitter With connectors on both ends For receiver Discrete wire With connectors on both ends With connector Connector on one end For receiver For emitter 3 Exclusive mating cable for SF-C14EX Adapter cable 3 Model No. SFB-CCB3 SFB-CCB7 SFB-CCB10 SFB-CCB15 With connector on one end Extension cable Bottom cap cable 5 Extension cable 6 Appearance Cable for series 7 connection Muting control components (12-core cable, with interference prevention wire) 4 Standard components (8-core cable) Type 7 Mating cable / Extension cable / Cables for series connection Mating cable is not supplied with the light curtain. Be sure to order it separately. For SF4-AH□ (PNP type) For SF4-AH□-N (NPN type) For SF2-EH□ (PNP type) For SF2-EH□-N (NPN type) SFB-CB05 SFB-CB5 SFB-CB10 SFB-CC3 SFB-CC10 SFB-CCJ3E SFB-CCJ10E SFB-CCJ3D SFB-CCJ10D SFB-CCB3-MU SFB-CCB7-MU SFB-CB05-MU Description (Note) Length: 3 m 9.843 ft Net weight: 370 g approx. (2 cables) Length: 7 m 22.966 ft Net weight: 820 g approx. (2 cables) Length: 10 m 32.808 ft Net weight: 1,160 g approx. (2 cables) Length: 15 m 49.213 ft Net weight: 1,710 g approx. (2 cables) Length: 0.5 m 1.640 ft Net weight: 95 g approx. (2 cables) Length: 5 m 16.404 ft Net weight: 620 g approx. (2 cables) Length: 10 m 32.808 ft Net weight: 1,200 g approx. (2 cables) Length: 3 m 9.843 ft Net weight: 380 g approx. (2 cables) Length: 10 m 32.808 ft Net weight: 1,200 g approx. (2 cables) Length: 3 m 9.843 ft Net weight: 190 g approx. (1 cables) Length: 10 m 32.808 ft Net weight: 580 g approx. (1 cable) Length: 3 m 9.843 ft Net weight: 210 g approx. (1 cables) Length: 10 m 32.808 ft Net weight: 600 g approx. (1 cable) Length: 3 m 9.843 ft Net weight: 420 g approx. (2 cables) Length: 7 m 22.966 ft Net weight: 930 g approx. (2 cables) SFB-CB05-A-P SFB-CB05-A-N SFB-CB05-B-P SFB-CB05-B-N Used for connecting to the light curtain and to an extension cable or the SF-C11 control unit. Two cables per set for emitter and receiver Connector outer diameter: ø14 mm ø0.551 in max. Used for cable extension or connecting to the SF-C13 control unit. Two cables per set for emitter and receiver Connector outer diameter: ø14 mm ø0.551 in max. Used for cable extension or connecting to the SF-C11 and the SF-C14EX control unit. One each for emitter and receiver Connector outer diameter: ø14 mm ø0.551 in max. Connector color: Gray (for emitter), Black (for receiver) Used for connecting to the light curtain and to other cables or the SF-C13 control unit. Two cables per set for emitter and receiver Used for connecting to the light curtain and to an extension Length: 0.5 m 1.640 ft cable or the SF-C12 control unit. Net weight: Two cables per set for emitter and receiver 110 g approx. (2 cables) Connector outer diameter: ø16 mm ø0.630 in max. Length: 3 m 9.843 ft Net weight: 430 g approx. (2 cables) Length: 7 m 22.966 ft SFB-CC7-MU Net weight: 1,000 g approx. (2 cables) Length: 10 m 32.808 ft SFB-CC10-MU Net weight: 1,300 g approx. (2 cables) Length: 3 m 9.843 ft SFB-CCJ3E-MU Net weight: 190 g approx. (1 cables) Length: 10 m 32.808 ft SFB-CCJ10E-MU Net weight: 660 g approx. (1 cable) Length: 3 m 9.843 ft SFB-CCJ3D-MU Net weight: 210 g approx. (1 cables) Length: 10 m 32.808 ft SFB-CCJ10D-MU Net weight: 680 g approx. (1 cable) Length: 0.1 m 0.328 ft SFB-CSL01 Net weight: 45 g approx. (2 cables) Length: 0.5 m 1.640 ft SFB-CSL05 Net weight: 95 g approx. (2 cables) Length: 1 m 3.281 ft SFB-CSL1 Net weight: 150 g approx. (2 cables) Length: 5 m 16.404 ft SFB-CSL5 Net weight: 630 g approx. (2 cables) Length: 0.5 m 1.640 ft SFB-CB05-EX Net weight: 95 g approx. (2 cables) Length: 5 m 16.404 ft SFB-CB5-EX Net weight: 620 g approx. (2 cables) Length: 10 m 32.808 ft SFB-CB10-EX Net weight: 1,200 g approx. (2 cables) SFB-CC3-MU Used for connecting to the light curtain and to other cables or the SF-C13 control unit. Two cables per set for emitter and receiver Used for connecting to an extension cable or the SF-C13 control unit. Two cables per set for emitter and receiver Connector outer diameter: ø16 mm ø0.630 in max. Used for connecting to an extension cable or the SF-C12 control unit. One each for emitter and receiver Connector color: Gray (for emitter), Black (for receiver) Connector outer diameter: ø16 mm ø0.630 in max. Used to connect light curtains in series Two cables per set for emitter and receiver (common for emitter and receiver) Cable color: Gray (common for emitter and receiver) Used for connecting to the light curtain and to SF-C14EX control unit or 8-core extension cable with connectors on both ends Two cables per set for emitter and receiver Connector outer diameter: ø14 mm ø0.551 in max. Used to allow connector cables connected to previous light curtains (at the control circuit side) to be smoothly adapted to the SF4B series. Length: 0.5 m 1.640 ft Also, SFB-CB05-A-P and SFB-CB05-A-N are usable even Net weight: when external device input is not used as the polarity of PNP 110 g approx. (2 cables) output or NPN output is fixed. Two cables per set for emitter and receiver Connector outer diameter: ø14 mm ø0.551 in max. Note: Where the cable color has not been specified, it is black for emitter, gray with black line for outer diameter is ø6 mm ø0.236 in, min. bending radius is R6 mm R0.236 in. For details of mating cable of CC-Link Safety system remote I/O unit with connectors for light curtain SF-CL1T264T, refer to website. 12 ORDER GUIDE Intermediate supporting bracket Spare parts (Accessories for light curtain) Designation Intermediate supporting bracket (Excluding SF4B-□G□) (Note 1) Intermediate support‑ ing bracket (Note 2) (For SF4B-□G□) Test rod ø14 Test rod ø25 Model No. MS-SFB-2 Used to mount the light curtain on the intermediate position. (2 pcs. per set for emitter and receiver) Mounting is possible behind or at the side of the light curtain. MS-SF4BG-2 Used to mount the light curtain in the intermediate position. (2 pcs. per set for emitter and receiver) Mounting is possible behind or at the side of the light curtain. SF4B-TR14 Min. sensing object for regular checking (ø14 mm ø0.551 in), with finger protection type (min. sensing object ø14 mm ø0.551 in) SF4B-TR25 Min. sensing object for regular checking (ø25 mm ø0.984 in), with hand protection type (min. sensing object ø25 mm ø0.984 in) Notes: 1) T  he number of sets required varies depending on the product. 1 set: SF4B-F□.............................. Light curtain with 79 to 111 beam channels SF4B-H□.............................. Light curtain with 40 to 56 beam channels SF4B-A□.............................. Light curtain with 20 to 28 beam channels 2 sets: SF4B-F127□ SF4B-H□.............................. Light curtain with 64 to 80 beam channels SF4B-A□.............................. Light curtain with 32 to 40 beam channels 3 sets: SF4B-H□.............................. Light curtain with 88 to 96 beam channels SF4B-A□.............................. Light curtain with 44 to 48 beam channels • MS-SFB-2 Description 2) The number of sets required varies depending on the product. 1 set: SF4B-F□G........................... Light curtain with 79 to 127 beam channels SF4B-H□G□......................... Light curtain with 40 to 64 beam channels SF4B-A□G........................... Light curtain with 20 to 32 beam channels 2 set: SF4B-H□G□......................... Light curtain with 72 to 96 beam channels SF4B-A□G........................... Light curtain with 36 to 48 beam channels Light curtain M5 hexagonsocket-head bolt Purchase separately. Intermediate supporting bracket MS-SFB-2 Sensing surface M5 hexagonsocket-head bolt Purchase separately. Light curtain Intermediate supporting bracket MS-SFB-2 Sensing surface • MS-SF4BG-2 M5 hexagon-sockethead bolt (Purchase separately.) Material: Cold rolled carbon steel (SPCC) M5 hexagon-sockethead bolt (Purchase separately.) Material: Cold rolled carbon steel (SPCC) OPTIONS Exclusive control units Designation Appearance Model No. Application cable Description SF-C11 Use 8-core cable with connector to connect to the light curtain. Bottom cap cable: SFB-CB□ Compatible with up to Control Category 4. Extension cable: SFB-CCJ□ Interference prevention wires and muting function cannot be used. Robust type control unit SF-C12 Use 12-core cable with connector to connect to the light Bottom cap cable: curtain. SFB-CB05-MU Compatible with up to Control Category 4. Extension cable: Muting function cannot be used. SFB-CCJ□-MU Interference prevention wires can be used. Slim type control unit SF-C13 Bottom cap cable: SFB-CCB□(-MU) Extension cable: SFB-CC□(-MU) Use a discrete wire cable to connect to the light curtain. Compatible with up to Control Category 4. Interference prevention wires and muting function can be used. Application expansion unit for SF4B series SF-C14EX Bottom cap cable:  SFB-CB□-EX Extension cable:  SFB-CCJ□ The muting control function and emergency stop input expand the applications of the light curtains. Use exclusive cable to connect to the light curtain. Compatible with up to Control Category 4. The handy-controller SFB-HC cannot be used with SF‑C14EX‑01. Bottom cap cable: SFB-CB□-CL Extension cable: SFB-CCJ10□-CL This is a remote I/O unit that allows the safety field network “CC-Link Safety” to be connected to the light curtains or the safety components. Use exclusive cable to connect to the light curtain. Compatible with up to Control Category 4. Please contact our office for details. Connector connection type control unit Handy-controller non-compatible type CC-Link Safety system remote I/O unit for light curtain (Note) SF-C14EX-01 SF-CL1T264T Note: Refer to our website for details of the remote I/O unit SF-CL1T264T. SF-C12 spare relay set A set of spare relays (2 safety relays and 1 removal tool) is available for the safety relay that is built into the SF-C12. Model No.: SF-C12-RY 13 OPTIONS ●Recommended safety relay Safety relay Panasonic Corporation SF relay slim type SF relay slim type SFS3-L-DC24V (AG1S132) SFS4-L-DC24V (AG1S142) DIN terminal block SFS4-SFD (AG1S847) [4-pole type] SFS6-SFD (AG1S867) [6-pole type] Note: Contact Panasonic Corporation for details on the recommended products. Item Type Model No. Part No. With LED indicator SFS3-L-DC24V SFS4-L-DC24V AG1S132 AG1S142 3a1b 4a2b Contact arrangement Rated nominal switching capacity Min. switching capacity Coil rating Rated power consumption Operation time Release time Ambient temperature Applicable standards 6 A / 250 V AC, 6 A / 30 V DC 1 mA / 5 V DC 15 mA / 24 V DC 20.8 mA / 24 V DC 360 mW 500 mW 20 ms or less 20 ms or less -40 to +85 °C -40 to +185 °F (Humidity: 5 to 85 % RH) UL, C-UL, TÜV, Korea S-mark Handy-controller Designation Appearance Model No. Pigtailed type In case of 8-core Bottom cap cable (Note) Fix ed Floa bla ting nki Aux blan ng Lig iliary king ht out con em put trol issi on Handycontroller SFB-HC Co de Mo nit Pr or ote Co ct FU py NC TIO N CA NC (Note) EL EN Extension cable 8-core 8-core In case of 12-core FUNCTION 12-core → 8-core TE R 8-core → 12-core CANCEL Bottom cap cable (Note) * Includes 2 adapter cables Cable set for cable type connection SFC-WNC1 (Note) Note: A  handy-controller cannot be used with the SF4B-□-01, the SF4B-□-03 and the SF-C14EX-01. Adapter cable (Accessory) ENTER Handy-controller Adapter cable (Accessory) Extension cable Note: If using a bottom cap cable with discrete wire, please order the SFB-CC3/CC10 separately. Refer to the instruction manual for the light curtain for details on wiring. Cable type 12-core → 8-core Cable set +V 0V Synchronization - Adapter cable (Accessory) Not used 8-core 8-core Synchronization + Control circuit FUNCTION Appearance Model No. Wire-saving Y-shaped connector SFB-WY1 (Note) WY1-CCN3 (Note) Cable with connector on one side WY1-CCN10 (Note) ENTER Handy-controller Terminal block Y-shaped connector Type CANCEL Description Wire-saving connector for standard components (8-core cable). Cables of emitter and receiver are consolidated into one cable for wire-saving. Wiring has +24 V, 0 V, OSSD 1, OSSD 2, output polarity setting wire (shield). Power wire and synchronization wire are connected inside the connector. Interlock is disabled (automatic reset). Cable length: 3 m 9.843 ft Net weight: 200 g approx. (1 cable) Mating cable for Y-shaped connector Cable color: Gray (with black line) Connector color: Black Cable length: 10 m 32.808 ft The min. bending radius: R6 mm R0.236 in Net weight: 620 g approx. (1 cable) Note: Not available for SF4B-□-01. By using the Y-shaped connector, the least required wires such as power or safety output are consolidated into one cable. Man-hours taken for wiring is eliminated to the minimum. Construction times as well as wiring mistakes are greatly reduced. Previous A total of 16 wires Y-shaped connector SF4B series SF4B series Only 5 wires Less wiring mistakes! Reduced wiring time! Easy wiring to safety PLC, etc. Safety PLC / remote I/O Safety relay unit SF-C13 8 wires Safety PLC / remote I/O Safety relay unit SF-C13 Y-shaped connector 5 wires 8 wires Refer to the operation manual SF4B for more detail such as installation of Y-shaped connector, terminal wiring, and wiring example. 14 OPTIONS Product configuration Emitter Receiver Extension cable (1 cable for receiver) Extension cable SFB-CCJ3D (3 m 9.843 ft) SFB-CCJ10D (10 m 32.808 ft) Y-shaped connector SFB-WY1 Extension cable (1 cable for emitter) Bottom cap cable (2 cables for emitter and receiver) SFB-CCJ3D (3 m 9.843 ft) SFB-CCJ10D (10 m 32.808 ft) WY1-CCN3 (3 m 9.843 ft) WY1-CCN10 (10 m 32.808 ft) SFB-CCJ3E (3 m 9.843 ft) SFB-CCJ10E (10 m 32.808 ft) SFB-CB05 (0.5 m 1.64 ft) SFB-CB5 (5 m 16.404 ft) SFB-CB10 (10 m 32.808 ft) Cable with connector on one side (Common for all models) Connector pin No. Connector pin layout Black connector 2 1 8 3 Receiver 7 Emitter 6 4 5 Gray connector Description 1 OSSD 2 2 +24 V 3 OSSD 1 4 Not used 5 Not used 6 Not used 7 0V 8 Output polarity setting wire (Shield) Wiring diagram of control unit SF-C13 For PNP output (minus ground) For NPN output (plus ground) • Connect the light curtain control outputs OSSD 1 and OSSD 2 to S1 and S2 respectively. • Connect the light curtain control outputs OSSD 1 and OSSD 2 to S4 and S2 respectively and ground the + side. Light curtain (SF4B series) Light curtain (SF4B series) Y-shaped connector WY1-CCN□ +24 V DC +24 V DC Not used (Yellow-green) +24 V (Brown) 0V (Blue) Output polarity setting wire (Shield) Not used (Gray) Not used (Gray / Black) Not used (Gray / Black) Output polarity setting wire 0 V (Shield) (Blue) OSSD 2 (White) OSSD 2 (White) S1 OSSD 1 (Black) L1 RESET (Note 1) (Note 1) FUSE1 FUSE2 (Note 2) S2 S3 S4 X1 X2 X3 13 23 33 41 F Ui Not used (Yellow-green) +24 V (Brown) Not used (Gray) OSSD 1 (Black) A1 Y-shaped connector WY1-CCN□ (Note 1) FUSE1 A1 F.G. K1 S1 S2 S3 S4 X1 X2 F Ui SF-C13 control circuit A2 0V INTER_LOCK AUX KA, KB: Force-guided relay F.G. or magnet contactor KA N FUSE2 33 41 SF-C13 control circuit RESET (Note 1) (Note 2) K2 FAULT 14 24 X3 13 23 K1 K2 OUT L1 34 42 L1L2L3 KB OUT KB KA M 3~ Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) Unused wires must be insulated. A2 0V INTER_LOCK FAULT 14 24 34 42 AUX KA, KB: Force-guided relay KB or magnet contactor KA N L1L2L3 KB KA M 3~ Notes: 1) T  he above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) Unused wires must be insulated. 15 OPTIONS Front protection cover (except for SF4B-□G□) / Protection bar set (except for SF4B-□G□) / Corner mirror Designation Applicable beam axes Front protection cover Protection bar set Rear / side protection bar set Corner mirror Finger Hand Arm / foot Model No. Model No. Model No. Model No. 23 12 6 Effective reflective surface 31 16 8 39 20 10 47 24 12 55 28 14 63 32 16 71 36 18 79 40 20 95 48 24 111 56 28 127 64 32 – 72 36 – 80 40 – 88 44 – 96 48 FC-SFBH-12 FC-SFBH-16 FC-SFBH-20 FC-SFBH-24 FC-SFBH-28 FC-SFBH-32 FC-SFBH-36 FC-SFBH-40 FC-SFBH-48 FC-SFBH-56 FC-SFBH-64 FC-SFBH-72 FC-SFBH-80 FC-SFBH-88 FC-SFBH-96 MC-SFBH-12 MC-SFBH-16 MC-SFBH-20 MC-SFBH-24 MC-SFBH-28 MC-SFBH-32 MC-SFBH-36 MC-SFBH-40 MC-SFBH-48 MC-SFBH-56 MC-SFBH-64 MC-SFBH-72 MC-SFBH-80 MC-SFBH-88 MC-SFBH-96 MC-SFBH-12-T MC-SFBH-16-T MC-SFBH-20-T MC-SFBH-24-T MC-SFBH-28-T MC-SFBH-32-T MC-SFBH-36-T MC-SFBH-40-T MC-SFBH-48-T MC-SFBH-56-T MC-SFBH-64-T MC-SFBH-72-T MC-SFBH-80-T MC-SFBH-88-T MC-SFBH-96-T RF-SFBH-12 RF-SFBH-16 RF-SFBH-20 RF-SFBH-24 RF-SFBH-28 RF-SFBH-32 RF-SFBH-36 RF-SFBH-40 RF-SFBH-48 RF-SFBH-56 RF-SFBH-64 RF-SFBH-72 RF-SFBH-80 RF-SFBH-88 RF-SFBH-96 236 × 72 mm 9.291 × 2.835 in 316 × 72 mm 12.441 × 2.835 in 396 × 72 mm 15.591 × 2.835 in 476 × 72 mm 18.740 × 2.835 in 556 × 72 mm 21.890 × 2.835 in 636 × 72 mm 25.039 × 2.835 in 716 × 72 mm 28.189 × 2.835 in 796 × 72 mm 31.339 × 2.835 in 956 × 72 mm 37.638 × 2.835 in 1,116 × 72 mm 43.937 × 2.835 in 1,276 × 72 mm 50.236 × 2.835 in 1,436 × 72 mm 56.535 × 2.835 in 1,596 × 72 mm 62.835 × 2.835 in 1,756 × 72 mm 69.134 × 2.835 in 1,916 × 72 mm 75.433 × 2.835 in Note: T  he model Nos. given above denote a single unit, not a pair of units. 2 units are required for use in mounting to the emitter / receiver. (Except for corner mirror) Front protection cover Protection bar set Front protection cover • FC-SFBH-□ Rear / side protection bar set • MC-SFBH-□ • MC-SFBH-□-T * Not available for SF4B-□G□. * Not available for SF4B-□G□. M5 hexagon Protects sensing surface of the light curtain from flying objects such as welding spatter. The operating range reduces when the front protection cover is used. socket-head bolt with washers M5 hexagonsocket-head bolt Note: Not available for SF4B-□G□. Material: Polycarbonate Protection bar mounting bracket M5 hexagonsocket-head bolt Sensing range Light curtain SF4B-H□ SF4B-A□ SF4B-F□ 12 to 64 beam 72 to 96 beam 6 to 32 beam 36 to 48 beam axes type axes type axes type axes type Only emitter installed Only receiver installed Protection bar intermediate supporting bracket MS-SFB-6 (Optional) (Note 2) Protection bar 0.3 to 6 m 0.3 to 7.5 m 0.3 to 6 m 0.3 to 7.5 m 0.3 to 6 m 0.984 to 19.685 ft 0.984 to 24.606 ft 0.984 to 19.685 ft 0.984 to 24.606 ft 0.984 to 19.685 ft M5 hexagonsocket-head bolt Both emitter and 0.3 to 5.5 m 0.3 to 7 m 0.3 to 5.5 m 0.3 to 7 m 0.3 to 5.5 m receiver installed 0.984 to 18.045 ft 0.984 to 22.966 ft 0.984 to 18.045 ft 0.984 to 22.966 ft 0.984 to 18.045 ft Note: The operating range is the possible setting distance between the emitter and the receiver. Corner mirror M5 hexagonsocket-head bolt • RF-SFBH-□ • Parts List Normally for an L-shaped or U-shaped installation, 2 or 3 sets of light curtains are needed. With the use of a corner mirror reflecting the light, one set of light curtain is possible for L-shaped or U-shaped installation. Designation Protection bar MC-SFBH-□ Number Remarks MC-SFBH-□-T Number Remarks 1 pc. Material: Aluminum 1 pc. Material: Aluminum Protection bar Material: Cold rolled 1 pc. Material: 1 pc. each mounting bracket carbon steel (SPCC) each Die-cast zinc alloy (Note 1) (For left side, for right side) (Trivalent chrome plated) Sensing range Corner mirror RF-SFBH-□ With 1 mirror Declined to 90 % With 2 mirrors Declined to 80 % Hexagon-socket-head M5 M5 2 pcs. 2 pcs. (length: 20 mm 0.787 in) (length: 20 mm 0.787 in) bolt with washers Hexagon-socket-head M5 M5 2 pcs. 2 pcs. (length: 16 mm 0.630 in) (length: 18 mm 0.709 in) bolt Protection bar intermediate supporting bracket MS-SFB-6 (Optional) (Note 2) 1 pc. Material: Cold rolled Material: Cold rolled carbon steel (SPCC) carbon steel (SPCC) 1 pc. Trivalent Trivalent chrome plated chrome plated Notes: 1) A  vailable as a spare part. Model No.: MS-MCSFB-1-T 2) T  he protection bar intermediate supporting bracket MS-SFB-6 (optional) is installed to protection bars that are longer than the MC-SFBH-48(-T). Use if there is much flexure bending in the protection bar. Please contact our office for details. 16 OPTIONS Front protection cover (For SF4B-□G□) Designation Applicable beam axes Side stopper (Accessory for a front protection cover) Finger Hand Arm / foot Model No. 23 12 6 31 16 8 39 20 10 47 24 12 55 28 14 63 32 16 71 36 18 79 40 20 95 48 24 111 56 28 127 64 32 – 72 36 – 80 40 – 88 44 – 96 48 FC-SF4BG-H12 FC-SF4BG-H16 FC-SF4BG-H20 FC-SF4BG-H24 FC-SF4BG-H28 FC-SF4BG-H32 FC-SF4BG-H36 FC-SF4BG-H40 FC-SF4BG-H48 FC-SF4BG-H56 FC-SF4BG-H64 FC-SF4BG-H72 FC-SF4BG-H80 FC-SF4BG-H88 FC-SF4BG-H96 Bottom stopper Accessory for a front protection cover Bottom cap cable Material: Front protection cover ... Polycarbonate Top / Side / Bottom stopper ... Stainless steel (SUS304) Sensing range SF4B-A□G SF4B-H□G□ SF4B-F□G 12 to 64 beam 72 to 96 beam 6 to 32 beam 36 to 48 beam axes type axes type axes type axes type Only emitter installed Only receiver installed Test rod ø45 Model No. SF4B-TR45 Laser alignment tool SF-LAT-2N (Excluding SF4B-□G□) 0.3 to 6 m 0.3 to 7.5 m 0.3 to 6 m 0.3 to 7.5 m 0.3 to 6 m 0.984 to 19.685 ft 0.984 to 24.606 ft 0.984 to 19.685 ft 0.984 to 24.606 ft 0.984 to 19.685 ft 0.3 to 5.5 m Both emitter and 0.3 to 7 m 0.3 to 5.5 m 0.3 to 7 m 0.3 to 5.5 m receiver installed 0.984 to 18.045 ft 0.984 to 22.966 ft 0.984 to 18.045 ft 0.984 to 22.966 ft 0.984 to 18.045 ft Note: T  he operating range is the possible setting distance between the emitter and the receiver. Note: The model Nos. given above denote a single unit, not a pair of units. 2 units are required for use in mounting to the emitter / receiver. Designation Top stopper (Accessory for a front protection cover) Front protection cover Front protection cover Laser alignment tool (Excluding SF4B-□G□) Description Min. sensing object for regular checking (ø45 mm ø1.772 in), with arm / foot protection type (min. sensing object ø45 mm ø1.772 in) • SF-LAT-2N Allows easy beam axis alignment using easy-to-see laser beam Laser alignment tool SF-LAT-4BG Allows easy beam axis alignment using easy-to-see laser beam (For SF4B-□G□) Caution tape Attached to the side of the light curtain to alert workers to hazards SF-TP-BG10 (10 m 32.8 ft long) Laser alignment tool (For SF4B-□G□) • SF-LAT-4BG Designation Model No. Description With the auxiliary output of the light curtain, the operation is easily observable from various directions. Specifications • Supply voltage: 24 V DC ±15 % • Current consumption: 12 mA or less • Indicators: Orange LED (8 pcs. used) [Light up when external contact is ON] • Ambient temperature: –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed) • Material: POM (Enclosure) Polycarbonate (Cover) Cold rolled carbon steel (SPCC) (Bracket) • Cable: 0.3 mm2 2-core cabtyre cable, 3 m 9.843 ft long • Weight: 70 g approx. (including bracket) I/O circuit diagrams Large display unit for light curtain Color code (Brown) +V + 24 V DC – ±15 % Internal circuit • SF-TP-BG10 Large display unit for light curtain • SF-IND-2 With NPN output type SF-IND-2 Caution tape *1 Non-voltage contact or NPN open-collector transistor or M5 hexagon-sockethead bolt (length: 10 mm 0.394 in or more) Purchase separately. (Blue) – V *1 Users’ circuit With PNP output type Color code (Brown) +V *1 + 24 V DC – ±15 % (Blue) – V Internal circuit Users’ circuit *1 Non-voltage contact or PNP open-collector transistor or Attaches to top of light curtain. Tighten together the mounting bracket provided with the light curtain MS-SFB-1/4, MS-SFBG-1 and the attached mounting bracket of SF-IND-2. 17 SPECIFICATIONS Light curtain individual specifications SF4B-F□(G) Type Item Min. sensing object ø14 mm ø0.551 in type (10 mm 0.394 in beam pitch) Model No. (Note 2) SF4B-F23□ SF4B-F23G SF4B-F31□ SF4B-F31G SF4B-F39□ SF4B-F39G SF4B-F47□ SF4B-F47G SF4B-F55□ SF4B-F55G Number of beam channels 23 31 230 mm 9.055 in Protective height China Press compliant (GB4584) 244 mm 9.606 in 220 mm 8.661 in Current consumption 310 mm 12.205 in 39 324 mm 12.756 in 300 mm 11.811 in 47 404 mm 15.906 in 380 mm 14.960 in 2.4 × 10 –9 2.8 × 10 –9 MTTFd 470 mm 18.504 in 55 484 mm 19.055 in 460 mm 18.110 in 550 mm 21.654 in 564 mm 22.205 in 540 mm 21.260 in Emitter: 100 mA or less, Receiver: 160 mA or less Emitter: 80 mA or less, Receiver: 120 mA or less PFHd 3.2 × 10 –9 3.6 × 10–9 4.0 × 10–9 100 years or more Net weight (Total of emitter and receiver) Type Item 390 mm 15.354 in 510 g approx. 980 g approx. 660 g approx. 1,340 g approx. 810 g approx. 1,700 g approx. 960 g approx. 2,000 g approx. 1,110 g approx. 2,400 g approx. Min. sensing object ø14 mm ø0.551 in type (10 mm 0.394 in beam pitch) Model No. (Note 2) SF4B-F63□ SF4B-F63G SF4B-F71□ SF4B-F71G SF4B-F79□ SF4B-F79G SF4B-F95□〉 SF4B-F95G Number of beam channels 63 630 mm 24.803 in Protective height China Press compliant (GB4584) 71 644 mm 25.354 in 620 mm 24.409 in Current consumption 710 mm 27.953 in 79 724 mm 28.504 in 700 mm 27.559 in 790 mm 31.102 in 95 804 mm 31.654 in 780 mm 30.708 in 950 mm 37.402 in 964 mm 37.953 in 940 mm 37.007 in Emitter: 100 mA or less, Receiver: 160 mA or less Emitter: 115 mA or less, Receiver: 190 mA or less PFHd 4.4 × 10–9 4.8 × 10–9 MTTFd 5.2 × 10–9 6.0 × 10–9 100 years or more Net weight (Total of emitter and receiver) 1,260 g approx. 2,800 g approx. 1,420 g approx. 3,200 g approx. 1,570 g approx. 3,400 g approx. 1,870 g approx. 4,200 g approx. Type Min. sensing object ø14 mm ø0.551 in type (10 mm 0.394 in beam pitch) Item Model No. (Note 2) SF4B-F111□ SF4B-F111G SF4B-F127□ SF4B-F127G Number of beam channels Protective height China Press compliant (GB4584) Current consumption PFHd 111 1,110 mm 43.701 in 1,124 mm 44.252 in 1,100 mm 43.306 in 1,270 mm 50.000 in 1,284 mm 50.551 in 1,260 mm 49.606 in Emitter: 135 mA or less, Receiver: 230 mA or less 6.8 × 10–9 MTTFd Net weight (Total of emitter and receiver) 127 7.6 × 10–9 100 years or more 2,170 g approx. 5,000 g approx. 2,470 g approx. 5,600 g approx. Notes: 1) W  here measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. The model No. with “G“ is a robust type. 2) The models with the “-01” or “-03” cannot be used with the handy-controller SFB-HC. 18 SPECIFICATIONS SF4B-H□(G□) Type Item Min. sensing object ø25 mm ø0.984 in type (20 mm 0.787 in beam pitch) Model No. (Note 2) SF4B-H12□ SF4B-H12G□ SF4B-H16□ SF4B-H16G□ SF4B-H20□ SF4B-H20G□ SF4B-H24□ SF4B-H24G□ SF4B-H28□ SF4B-H28G□ Number of beam channels 12 230 mm 9.055 in Protective height China Press compliant (GB4584) 16 244 mm 9.606 in 220 mm 8.661 in Current consumption 310 mm 12.205 in 20 324 mm 12.756 in 300 mm 11.811 in 2.0 × 10 1.8 × 10 –9 –9 MTTFd 380 mm 14.960 in 470 mm 18.504 in 28 484 mm 19.055 in 550 mm 21.654 in 460 mm 18.110 in 564 mm 22.205 in 540 mm 21.260 in Emitter: 80 mA or less, Receiver: 115 mA or less 2.2 × 10 –9 2.4 × 10–9 2.6 × 10–9 100 years or more Net weight (Total of emitter and receiver) 510 g approx. 980 g approx. Type 660 g approx. 1,340 g approx. 810 g approx. 1,700 g approx. 960 g approx. 2,000 g approx. 1,110 g approx. 2,400 g approx. Min. sensing object ø25 mm ø0.984 in type (20 mm 0.787 in beam pitch) Model No. (Note 2) SF4B-H32□ SF4B-H32G□ SF4B-H36□ SF4B-H36G□ SF4B-H40□ SF4B-H40G□ SF4B-H48□ SF4B-H48G□ SF4B-H56□ SF4B-H56G□ Number of beam channels 32 630 mm 24.803 in Protective height China Press compliant (GB4584) 36 644 mm 25.354 in 620 mm 24.409 in Current consumption 710 mm 27.953 in 40 724 mm 28.504 in 700 mm 27.559 in Emitter: 80 mA or less, Receiver: 115 mA or less PFHd 2.8 × 10–9 3.0 × 10–9 MTTFd 790 mm 31.102 in 48 804 mm 31.654 in 780 mm 30.708 in 950 mm 37.402 in 56 964 mm 37.953 in 1,124 mm 44.252 in 1,100 mm 43.306 in 940 mm 37.007 in Emitter: 90 mA or less, Receiver: 140 mA or less 3.2 × 10–9 1,110 mm 43.701 in Emitter: 100 mA or less, Receiver: 160 mA or less 3.6 × 10–9 4.0 × 10–9 100 years or more Net weight (Total of emitter and receiver) 1,260 g approx. 2,800 g approx. Type Item 24 404 mm 15.906 in Emitter: 70 mA or less, Receiver: 95 mA or less PFHd Item 390 mm 15.354 in 1,420 g approx. 3,200 g approx. 1,570 g approx. 3,400 g approx. 1,870 g approx. 4,200 g approx. 2,170 g approx. 5,000 g approx. Min. sensing object ø25 mm ø0.984 in type (20 mm 0.787 in beam pitch) Model No. (Note 2) SF4B-H64□ SF4B-H64G SF4B-H72□ SF4B-H72G SF4B-H80□ SF4B-H80G SF4B-H88□ SF4B-H88G SF4B-H96□ SF4B-H96G□ Number of beam channels Protective height China Press compliant (GB4584) Current consumption PFHd 64 1,270 mm 50.000 in 72 1,284 mm 50.551 in 1,260 mm 49.606 in 1,430 mm 56.299 in 80 1,444 mm 56.850 in 1,420 mm 55.905 in 88 1,604 mm 63.150 in 1,580 mm 62.205 in 1,750 mm 68.898 in 96 1,764 mm 69.449 in 1,740 mm 68.503 in 1,910 mm 75.197 in 1,924 mm 75.748 in 1,900 mm 74.803 in Emitter: 100 mA or less, Emitter: 110 mA or less, Receiver: 180 mA or less Emitter: 120 mA or less, Receiver: 200 mA or less Receiver: 160 mA or less 4.4 × 10–9 4.8 × 10–9 MTTFd Net weight (Total of emitter and receiver) 1,590 mm 62.598 in 5.2 × 10–9 5.6 × 10–9 6.0 × 10–9 100 years or more 2,470 g approx. 5,600 g approx. 2,770 g approx. 6,400 g approx. 3,070 g approx. 7,000 g approx. 3,370 g approx. 7,800 g approx. 3,670 g approx. 8,400 g approx. Notes: 1) W  here measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. The model No. with “G“ is a robust type. 2) The models with the “-01” or “-03” cannot be used with the handy-controller SFB-HC. 19 SPECIFICATIONS SF4B-A□(G) Type Item Min. sensing object ø45 mm ø1.772 in type (40 mm 1.575 in beam pitch) Model No. (Note 2) SF4B-A6□ SF4B-A6G SF4B-A8□ SF4B-A8G SF4B-A10□ SF4B-A10G SF4B-A12□ SF4B-A12G SF4B-A14□ SF4B-A14G Number of beam channels 6 230 mm 9.055 in Protective height China Press compliant (GB4584) 8 244 mm 9.606 in 200 mm 7.874 in Current consumption 310 mm 12.205 in 10 324 mm 12.756 in 280 mm 11.024 in 1.6 × 10 1.5 × 10 –9 –9 MTTFd 360 mm 14.173 in 470 mm 18.504 in 14 484 mm 19.055 in 550 mm 21.654 in 440 mm 17.323 in 564 mm 22.205 in 520 mm 20.472 in Emitter: 70 mA or less, Receiver: 95 mA or less 1.7 × 10 –9 1.8 × 10–9 1.9 × 10–9 100 years or more Net weight (Total of emitter and receiver) 510 g approx. 980 g approx. Type 660 g approx. 1,340 g approx. 810 g approx. 1,700 g approx. 960 g approx. 2,000 g approx. 1,110 g approx. 2,400 g approx. Min. sensing object ø45 mm ø1.772 in type (40 mm 1.575 in beam pitch) Model No. (Note 2) SF4B-A16□ SF4B-A16G SF4B-A18□ SF4B-A18G SF4B-A20□ SF4B-A20G SF4B-A24□ SF4B-A24G SF4B-A28□ SF4B-A28G Number of beam channels 16 630 mm 24.803 in Protective height China Press compliant (GB4584) 18 644 mm 25.354 in 600 mm 23.622 in Current consumption 710 mm 27.953 in 20 724 mm 28.504 in 680 mm 26.772 in Emitter: 70 mA or less, Receiver: 95 mA or less PFHd 2.0 × 10–9 2.1 × 10–9 MTTFd 790 mm 31.102 in 24 804 mm 31.654 in 760 mm 29.921 in 950 mm 37.402 in 28 964 mm 37.953 in 920 mm 36.220 in Emitter: 75 mA or less, Receiver: 105 mA or less 2.2 × 10–9 1,110 mm 43.701 in 1,124 mm 44.252 in 1,080 mm 42.520 in Emitter: 80 mA or less, Receiver: 120 mA or less 2.4 × 10–9 2.6 × 10–9 100 years or more Net weight (Total of emitter and receiver) 1,260 g approx. 2,800 g approx. Type Item 12 404 mm 15.906 in Emitter: 65 mA or less, Receiver: 85 mA or less PFHd Item 390 mm 15.354 in 1,420 g approx. 3,200 g approx. 1,570 g approx. 3,400 g approx. 1,870 g approx. 4,200 g approx. 2,170 g approx. 5,000 g approx. Min. sensing object ø45 mm ø1.772 in type (40 mm 1.575 in beam pitch) Model No. (Note 2) SF4B-A32□ SF4B-A32G SF4B-A36□ SF4B-A36G SF4B-A40□ SF4B-A40G SF4B-A44□ SF4B-A44G SF4B-A48□ SF4B-A48G Number of beam channels Protective height China Press compliant (GB4584) Current consumption PFHd 32 1,270 mm 50.000 in 36 1,284 mm 50.551 in 1,240 mm 48.819 in 1,430 mm 56.299 in 40 1,444 mm 56.850 in 1,400 mm 55.118 in 44 1,604 mm 63.150 in 1,560 mm 61.417 in Emitter: 80 mA or less, Emitter: 85 mA or less, Receiver: 130 mA or less Receiver: 120 mA or less 2.8 × 10 –9 3.0 × 10 –9 MTTFd Net weight (Total of emitter and receiver) 1,590 mm 62.598 in 3.2 × 10 –9 1,750 mm 68.898 in 48 1,764 mm 69.449 in 1,720 mm 67.716 in 1,910 mm 75.197 in 1,924 mm 75.748 in 1,880 mm 74.016 in Emitter: 95 mA or less, Receiver: 140 mA or less 3.4 × 10–9 3.6 × 10–9 100 years or more 2,470 g approx. 5,600 g approx. 2,770 g approx. 6,400 g approx. 3,070 g approx. 7,000 g approx. 3,370 g approx. 7,800 g approx. 3,670 g approx. 8,400 g approx. Notes: 1) W  here measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. The model No. with “G“ is a robust type. 2) The models with the “-01” or “-03” cannot be used with the handy-controller SFB-HC. 20 SPECIFICATIONS Light curtain common specifications Type Min. sensing object ø14 mm ø0.551 in type Min. sensing object ø25 mm ø0.984 in type Min. sensing object ø45 mm ø1.772 in type SF4B-F□(G) SF4B-H□(G□) SF4B-A□(G) SFB-HC non-compatible SF4B-F□-01 SF4B-H□-01 SF4B-A□-01 Item Korean press compliant SF4B-F□-03 SF4B-H□-03 Applicable standards (Note 2) Model No. International standard Japan Europe (EU) North America IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 South Korea (S-Mark) S1-G-35-2005, S2-W-11-2003 (SF4B-□ only) China (GB) Operating range (Note 3) Min. sensing object (Note 4) Effective aperture angle Supply voltage Control outputs (OSSD 1, OSSD 2) Operation mode Protection circuit Response time Auxiliary output (Non-safety output) Operation mode Protection circuit Responce time GB 4584 (excluding SF4B-□-03) 0.3 to 7 m 0.984 to 22.966 ft ø14 mm ø0.551 in opaque object 12 to 64 beam channels type: 0.3 to 9 m 0.984 to 29.528 ft 6 to 32 beam channels type: 0.3 to 9 m 0.984 to 29.528 ft 72 to 96 beam channels type: 0.3 to 7 m 0.984 to 22.966 ft 36 to 48 beam channels type: 0.3 to 7 m 0.984 to 22.966 ft ø25 mm ø0.984 in opaque object ø45 mm ø1.772 in opaque object ±2.5° or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)] 24 V DC ±10 % Ripple P-P 10 % or less PNP open-collector transistor / NPN open-collector transistor (switching method) • When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA • Applied voltage: same as supply voltage When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V • Residual voltage: 2.5 V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the light curtain or the synchronization signal)(Note 5,6) Incorporated OFF response: 14 ms or less, ON response: 80 to 90 ms PNP open-collector transistor / NPN open-collector transistor (switching method) • When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA • Applied voltage: same as supply voltage When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V • Residual voltage: 2.5 V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) OFF when control outputs are ON, ON when control outputs are OFF [Factory setting, operating mode can be changed using the SFB-HC handy-controller (optional)]. Incorporated OFF replay: 34 ms or less, ON replay 110 ms or less Interference prevention function Incorporated (Note 7) (Available only when in series connection for SF4B-□-03) Emission halt function / Interlock function Incorporated / Incorporated [Manual reset / Auto reset (Note 8)] External device monitoring function Incorporated Override function / Muting function Incorporated (Note 7) (excluding SF4B-□-03) / Incorporated (Note 7) (excluding SF4B-□-03) Environmental resistance Optional functions (Note 9) Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control Degree of protection IP67 / IP65 (IEC) Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F Ambient humidity Ambient illuminance Dielectric strength voltage 30 to 85 % RH, Storage: 30 to 95 % RH Incandescent light: 3,500 ℓx or less at the light-receiving face 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each Shock resistance Emitting element Material Connecting method / Cable length Accessories 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) Enclosure: Aluminium, Upper and lower edges: Iron, Sensing surface: Polycarbonate and Polyester resin, Cap: PBT Connector / Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note 10) MS-SFB-2 (Intermediate supporting bracket): (Note 11) MS-SFB-2 (Intermediate supporting bracket): (Note 11) MS-SFB-2 MS-SF4BG-2 (Intermediate supporting bracket): (Note 12) MS-SF4BG-2 (Intermediate supporting bracket): (Note 12) (Intermediate supporting bracket): (Note 11) SF4B-TR14 (Test rod): 1 No. SF4B-TR25 (Test rod): 1 No. MS-SF4BG-2 (Intermediate supporting bracket): (Note 12) Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) PLe SIL3 compliant from production in August 2009. Model Nos. having the suffix “G” are robust type. 3) The operating range is the possible setting distance between the emitter and the receiver. 4) When the floating blanking function is used, the size of the min. sensing object is changed. For details, refer to “Safety distance” (p.36~). 5) The outputs are not “OFF” when muting function is active even if the beam channel is interruped. 6) In case the blanking function is valid, the operation mode is changed. For details, refer to “Safety distance” (p.36~). 7) In case of using this function, please use 12-core cable. 8) The manual reset and auto reset are possible to be switched depending on the wiring status. 9) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-□-01, SF4B-□-03 and the SF-C14EX-01. 10) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). 11) The intermediate supporting bracket (MS-SFB-2) is enclosed with the following models. The number of sets required varies depending on the product. 1 set: SF4B-F□............... Light curtain with 79 to 111 beam channels, SF4B-H□............... Light curtain with 40 to 56 beam channels, SF4B-A□.............. Light curtain with 20 to 28 beam channels 2 sets: SF4B-F127, SF4B-H□ ...Light curtain with 64 to 80 beam channels, SF4B-A□...Light curtain with 32 to 40 beam channels 3 sets: SF4B-H□.............. Light curtain with 88 to 96 beam channels, SF4B-A□................. Light curtain with 44 to 48 beam channels 12) The intermediate supporting bracket (MS-SF4BG-2) is enclosed with the following models. 1 set: SF4B-F□G............ Light curtain with 79 to 127 beam channels, SF4B-H□G□.......... Light curtain with 40 to 64 beam channels SF4B-A□G............ Light curtain with 20 to 32 beam channels 2 sets: SF4B-H□G□......... Light curtain with 72 to 96 beam channels, SF4B-A□G.............. Light curtain with 36 to 48 beam channels 21 SPECIFICATIONS Control units Connectable light curtains Applicable standards Control category Supply voltage / Current consumption Fuse (rating) Enabling path Utilization category Rated operation voltage (Ue) / Rated operation current (le) Contact resistance Contact protection fuse rating Pick-up delay (Auto reset / Manual reset) Response time Auxiliary output Rated operation voltage / current Contact protection fuse rating Semiconductor auxiliary output (AUX) Output operation Excess voltage category Polarity selection function (Note 4) Pollution degree Protection Ambient temperature Enclosure material Weight SF-C11 (Note 2) SF-C12 Notes: 1) W  here measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) SF-C11 and SF-C13 have acqusred the Korea S-mark. 3) If several SF-C11 or SF-C13 units are being used in a line together, leave a space of 5 mm 0.197 in or more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs at right. 4) Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground. 5) For details of control unit SF-C1□ (SF-C10 series), refer to the website or general catalog. Item Model No. SF-C13 (Note 2) SF4B / SF2B series SF4B series Light curtains manufactured by Panasonic Industrial Devices SUNX IEC 61496-1, EN 61496-1, ANSI/UL 61496-1, CAN/CSA 61496-1, JIS B 9704-1 ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards 24 V DC ±10 %   Ripple P-P 10 % or less / 100 mA or less (excluding light curtain) Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down NO contact × 3 (13-14, 23-24, 33-34) NO contact × 2 (13-14, 23-24) NO contact × 3 (13-14, 23-24, 33-34) AC-15, DC-13 (IEC 60947-5-1) 30 V DC / 6 A, 230 V AC / 6 A, resistive load 24 V DC / 1 A, resistive load 30 V DC / 4 A, 230 V AC / 4 A, resistive load (For inductive load, during contact protection) (For inductive load, during contact protection) (For inductive load, during contact protection) Min. applicable load: 10 mA (at 24 V DC) (Note 3) Min. applicable load: 15 mA (at 24 V DC) Min. applicable load: 10 mA (at 24 V DC) (Note3) 100 mΩ or less (initial value) 50 mΩ or less (initial value) 100 mΩ or less (initial value) 6 A (slow blow) 3 A (slow blow) 4 A (slow blow) 80 ms or less / 90 ms or less 30 ms or less / 30 ms or less 80 ms or less / 90 ms or less 10 ms or less 14 ms or less 10 ms or less Safety relay contact (NC contact) ×1 (41-42) (Related to enabling path) Safety relay contact (NC contact) × 1 (31-32) (Related to enabling path) Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path) 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) 30 V DC / 3 A, Min. applicable load: 15 mA (at 24 V DC) 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) 2 A (slow blow) 3 A (slow blow) 2 A (slow blow) – PNP open‑collector transistor PNP open-collector transistor NPN open-collector transistor – ON when the light curtain is interrupted Related to auxiliary output of light curtain Ⅱ Ⅲ Ⅱ Incorporated (Cable connection allows selection of plus / minus ground) Incorporated (Sliding switch allows selection of plus / minus ground) Minus ground: Correspond to PNP output light curtain Minus ground: Correspond to PNP output light curtain Plus ground: Correspond to NPN output light curtain Plus ground: Correspond to NPN output light curtain 2 Enclosure: IP40, Terminal: IP20 IP65 Enclosure: IP40, Terminal: IP20 –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F ABS Die-cast aluminum ABS Net weight: 320 g approx. Net weight: 1 kg approx. Net weight: 200 g approx. Dilating when SF-C11 units are mounted close together 6 5 4 3 2 1 0 32 Dilating when SF-C13 units are mounted close together Rated operation current (A) Model No. Rated operation current (A) Item 35 40 45 50 55 95 104 113 122 131 Ambient temperature (°C °F) 6 5 4 3 2 1 0 32 35 40 45 50 55 95 104 113 122 131 Ambient temperature (°C °F) SF-C14EX(-01) (Note 2) Connectable light curtains SF4B series Applicable standards IEC 61496-1, EN 61496-1, ANSI/UL 61496-1, CAN/CSA 61496-1, JIS B 9704-1 Control category ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards Supply voltage / Current consumption 24 V DC ±10 % Ripple P-P 10 % or less / 0.2 A or less (Excluding light curtain and other external connecting device) Enabling path (Enabling path 1, 2, 3) PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch) Enabling path 1: ON when the light curtain is in light receiving condition, OFF when the light curtain is in light interrupted condition (Note 3) Operation mode Enabling path 2: ON when the light curtain is in light receiving condition or the muting function is valid (Output operation) OFF when the light curtain is in light interrupted condition and the muting function is invalid (Note 3) Enabling path 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid OFF response: 14 ms or less (Enabling path 1 and 2: including the response time of the light curtain) Response time ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note 4) PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch) Auxiliary outputs Auxiliary output 1, 2, 3, 4 • Maximum source current: 60 mA or less • Maximum sink current: 60 mA or less (Note 5) • Applied voltage: same as supply voltage (between the auxiliary output and +V) • Applied voltage: same as supply voltage (between the auxiliary output and 0 V) • Residual voltage: 2 V or less (at 60 mA source current) • Residual voltage: 2 V or less (at 60 mA sink current) Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is valid Auxiliary output 2: ON when the override function is invalid, OFF when the override function is valid Operation mode Auxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is error (Output operation) Auxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition (Note 5) Muting lamp output Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit) Protection Enclosure: IP40, Terminal: IP20 Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F Material Enclosure: ABS Connection terminal Detachable spring-cage terminal Weight Net weight: 250 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) SF-C14EX-01 is Handy-controller non-compatible type. 3) Both enabling path 1 and 2 are OFF when the emergency stop is valid regardless of whether the light curtain is in the light receiving or light interrupted condition. 4) The auto-reset cannot be used with enabling path 3. 5) The auxiliary output incorporated in the SF4B series is outputed. 6) For details of control unit SF-C14EX(-01), refer to the website or general catalog. 22 SPECIFICATIONS Handy-controller Model No. Item Supply voltage SFB-HC 24 V DC ±10 % Ripple P-P10 % or less (common to light curtain power supply) Current consumption Communication method Digital display 65 mA or less RS-485 two-way communications (Specific procedure) 4-digit red LED display × 2 (Selected beam channels, setting contents etc. are displayed.) Function indicator Green LED × 9 (set function is displayed.) Fixed blanking (Factory setting: Disabled) / Floating blanking (Factory setting: Disabled) / Auxiliary output change (Factory setting: Negative Logic of OSSD) / Light emitting amount control (Factory setting: Disabled) / Muting setting change [Factory setting: All beam channels enabled, A = B, Setting of the muting lamp diagnosis function enabled (Ver. 2 or later), Muting sensor output operation setting N.O. / N.C. (Ver. 2.1 or later)] Interlock setting change (Factory setting: start / restart) / External device monitoring setting change (Factory setting: Enabled, 300 ms) / Override setting changing function 60 sec. (Ver. 2.1 or later) / Setting detail monitoring / Protecting (Factory setting: Disabled)(Factory password setting: 0000) / Initialization / Copy Functions Ambient temperature Ambient humidity –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F 30 to 85 % RH, Storage: 30 to 85 % RH Voltage withstandability Insulation resistance Cable 1,000 V AC for one min. between all supply terminals connected together and enclosure 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure 8-core shielded cable, 0.5 m 1.640 ft long, with a connector at the end (2 cables) Material Enclosure: ABS Weight Net weight: 200 g approx. Accessories Adapter cable: 2 cables Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. Laser alignment tool Model No. Item Supply voltage SF-LAT-2N / SF-LAT-4BG (For SF4B-□G□) 3 V (LR6 battery × 2 pcs.) Battery 1.5 V (LR6 battery) × 2 pcs. (replaceable) Battery lifetime 30 hours approx. of continuous operation (LR6 battery, at +25 °C +77 °F ambient temperature) Red semiconductor laser: Class 2 (IEC / JIS / FDA) (Max. output: 1 mW, Peak emission wavelength: 650 nm 0.026 mil) (Note 2) Light source Spot diameter 10 mm 0.394 in approx. (at 5 m 16.404 ft distance) Ambient temperature Ambient humidity 0 to +40 °C +32 to +104 °F (No dew condensation), Storage: 0 to +55 °C +32 to +131 °F 35 to 85 % RH, Storage: 35 to 85 % RH Material Enclosure: ABS, Mounting part: Aluminum Weight Net weight: 200 g approx. (including batteries) Accessories LR6 battery: 2 pcs. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) As for FDA regulation, the product complies with 21 CFR 1040.10 and 1040.11 based on Laser Notice No. 50, dated June 24, 2007, issued by CDRH under the FDA. Corner mirror Model No. Item RF-SFBH-□ With one mirror: Declined to 90 %, With two mirrors: Declined to 80 % (When used in combination with the SF4B series) Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F Environmental resistance Attenuation rate of sensing range Ambient humidity Vibration resistance Shock resistance Material Accessories 30 to 85 % RH, Storage: 30 to 95 % RH 10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each Enclosure: Alminium, Mounting bracket: Stainless steel, Mirror (rear surface mirror): Glass, Side cover: EPDM Intermediate supporting bracket: 1 set (RF-SFBH-40/48/56/64), 2 sets (RF-SFBH-72/80/88/96) Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 23 I/O CIRCUIT AND WIRING DIAGRAMS Refer to the manual on our website for details. I/O circuit diagram In case of using I/O circuit for PNP output Emitter In case of using I/O circuit for NPN output Emitter Color code of mating cable Color code of mating cable (Brown) +V (Red) Muting lamp output * S1 (Brown) +V (Shield) Output polarity setting wire * S1 * S1 + – (Gray) Interference prevention + (Gray / Black) Interference prevention – 0.22 μF 470 Ω 0.22 μF 470 Ω 0.22 μF 470 Ω (Yellow) Override input (Pale purple) Interlock setting input 24 V DC ±10 % 470 Ω 0.22 μF 470 Ω 0.22 μF 470 Ω (Yellow) Override input (Pale purple) Interlock setting input (Pink) Emission halt input / Reset input Load (Gray) Interference prevention + (Gray / Black) Interference prevention – Sensor circuit Sensor circuit (Yellow-green / Black) Auxiliary output 0.22 μF (Yellow-green / Black) Auxiliary output * S1 Load (Pink) Emission halt input / Reset input + – * S1 24 V DC ±10 % * S1 (Red) Muting lamp output (Shield) Output polarity setting wire Internal circuit Receiver (Blue) 0 V (Blue) 0 V (Orange) Synchronization + (Orange) Synchronization + (Orange / Black) Synchronization – Users’ circuit Receiver (Orange / Black) Synchronization – (Orange) Synchronization + * S1 (Brown) +V (Gray) Interference prevention + (Gray / Black) Interference prevention – 0.047 μF 1 kΩ Users’ circuit (Orange / Black) Synchronization – (Orange) Synchronization + (Brown) +V * S1 (Shield) Output polarity setting wire K1 (Sky-blue / White) Muting input A (Sky-blue / Black) Muting input B K1 (Black) OSSD 1 K2 K2 (Yellow-green) External device monitoring input Sensor circuit 0.047 μF 1 kΩ Sensor circuit (Orange / Black) Synchronization – Internal circuit 0.22 μF 470 Ω (Black) OSSD 1 (White) OSSD 2 (Gray) Interference prevention + (Gray / Black) Interference prevention – (White) OSSD 2 (Shield) Output polarity setting wire 0.22 μF 470 Ω 0.047 μF 1 kΩ 0.047 μF 1 kΩ K1 K2 (Blue) 0 V K1, K2: Force-guided relay or magnet contactor K1, K2: Force-guided relay or magnet contactor Internal circuit Internal circuit Users’ circuit Users’ circuit Note: The above diagram is when using a 12-core cable. If an 8-core cable is used, the red, yellow, gray, gray / black, sky-blue / white and skyblue / black lead wires are absent. Note: The above diagram is when using a 12-core cable. If an 8-core cable is used, the red, yellow, gray, gray / black, sky-blue / white and skyblue / black lead wires are absent. * S1 * S1 Switch S1 • Emission halt input / Reset input For manual reset Vs to Vs – 2.5 V (sink current 5 mA or less): Emission halt (Note 1) Open: Emission For automatic reset Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note 1) Open: Emission halt • Interlock setting input, Override input, Muting input A / B, External device monitoring input Vs to Vs – 2.5 V (sink current 5 mA or less): Enabled (Note 1) Open: Disabled Note: Vs is the applying supply voltage. 24 (Yellow-green) External device monitoring input (Sky-blue / White) Muting input A K1 * S1 (Sky-blue / Black) Muting input B K2 * S1 (Blue) 0 V Switch S1 • Emission halt input / Reset input For manual reset 0 to +1.5 V (source current 5 mA or less): Emission halt Open: Emission For automatic reset 0 to +1.5 V (source current 5 mA or less): Emission Open: Emission halt • Interlock setting input, Override input, Muting input A / B, External device monitor input 0 to +1.5 V (source current 5 mA or less): Enabled Open: Disabled I/O CIRCUIT AND WIRING DIAGRAMS Refer to the manual on our website for details. Connection example Standard components (8-core cable): Interlock function “enabled (manual reset)”, external device monitoring function “enabled” In case of using I/O circuit for PNP output Emitter Color code of mating cable (Brown) +V The diagram at left shows the configuration when using PNP output, interlock function “enabled (manual reset)” and external device monitoring function “enabled”. * S1 (Yellow-green / Black) Auxiliary output Cable color: Gray (Pale purple) Interlock setting input (Pink) Emission halt input / Reset input Load (Shield) Output polarity setting wire (Blue) 0 V (Orange) Synchronization + Receiver + – 24 V DC ±10 % In case of setting the interlock function to “disabled (automatic reset)” Emitter (Orange / Black) Synchronization – (Pink) Emission halt input / Reset input (Orange / Black) Synchronization – (Pale purple) Interlock setting input (Orange) Synchronization + Cable color: Gray with black line +24 V DC * S1 Open (Brown) +V * Refer to the SF4B manual for details of the interlock function. K1 (Yellow-green) External device monitoring input K2 In case of setting the external device monitoring function to “disabled” (Black) OSSD 1 (White) OSSD 2 (Shield) Output polarity setting wire Emitter K1 K2 (Blue) 0 V * S1 K1, K2: Forced-guided relay or magnet contactor Switch S1 • Emission halt input / Reset input For manual reset Vs to Vs – 2.5 V (sink current 5 mA or less): Emission halt (Note) Open: Emission For automatic reset Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note) Open: Emission halt * Refer to the SF4B manual for details of the external device monitoring function. In case of using I/O circuit for NPN output Cable color: Gray The diagram at left shows the configuration when using NPN output, interlock function “enabled (manual reset)” and external device monitoring function “enabled”. Color code of mating cable (Brown) +V (Shield) Output polarity setting wire (Pale purple) Interlock setting input (Pink) Emission halt input / Reset input (Yellow-green / Black) Auxiliary output * S1 Receiver (Yellow-green) External device monitoring input Note: Vs is the applying supply voltage. Emitter (Yellow-green / Black) Auxiliary output Load In case of setting the interlock function to “disabled (automatic reset)” + – 24 V DC ±10 % Emitter (Blue) 0 V (Orange) Synchronization + Receiver (Orange / Black) Synchronization – (Pale purple) Interlock setting input (Orange / Black) Synchronization – (Pink) Emission halt input / Reset input * S1 (Orange) Synchronization + Cable color: Gray with black line (Brown) +V (Shield) Output polarity setting wire 0V K1 K2 (Black) OSSD 1 (White) OSSD 2 (Yellow-green) External device monitoring input (Blue) 0 V * S1 Open * Refer to the SF4B manual for details of the interlock function. In case of setting the external device monitoring function to “disabled” K1 K2 Emitter K1, K2: Forced-guided relay or magnet contactor Switch S1 • Emission halt input / Reset input For manual reset 0 to +1.5 V (source current 5 mA or less): Emission halt Open: Emission For automatic reset 0 to +1.5 V (source current 5 mA or less): Emission Open: Emission halt (Yellow-green / Black) Auxiliary output Receiver (Yellow-green) External device monitoring input * Refer to the SF4B manual for details of the external device monitoring function. 25 I/O CIRCUIT AND WIRING DIAGRAMS Refer to the manual on our website for details. Connection example Muting control components (12-core cable, with interference prevention wires): Interlock function “disabled (automatic reset)”, external device monitoring function “disabled” In case of using I/O circuit for PNP output Color code of mating cable Emitter (Red) Muting lamp output Cable color: Gray The diagram at left shows the configuration when using PNP output, interlock function “disabled (automatic reset)” and external device monitoring function “disabled”. (Brown) +V * S1 (Gray) Interference prevention + Uses when the interference prevention function is used (Gray / Black) Interference prevention – (Yellow) Override input (Pale purple) Interlock setting input: Open (Pink) Emission halt input / Reset input (Shield) Output polarity setting wire (Blue) 0 V (Orange) Synchronization + Receiver Cable color: Gray with black line * S1 In case of setting the interlock function to “enabled (manual reset)” * S1 (Yellow-green / Black) Auxiliary output • When the interlock function is “enabled (manual reset)”, the override function cannot be used. + – 24 V DC ±10 % Emitter (Pink) Emission halt input / Reset input (Orange / Black) Synchronization – (Orange / Black) Synchronization – (Orange) Synchronization + (Brown) +V +24 V DC * S1 (Pale purple) Interlock setting input * Refer to the SF4B manual for details of the interlock function. * S1 (Gray) Interference prevention + Uses when the interference * S1 prevention function is used (Gray / Black) Interference prevention – (Sky-blue / White) Muting input A (Sky-blue / Black) Muting input B (Yellow-green) External device monitoring input (Black) OSSD 1 (White) OSSD 2 K1, K2: ForcedK1 (Shield) Output polarity setting wire guided relay or K2 (Blue) 0 V magnet contactor Switch S1 • Emission halt input / Reset input For manual reset Vs to Vs – 2.5 V (sink current 5 mA or less): Emission halt (Note), Open: Emission For automatic reset Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note), Open: Emission halt • Override input, Muting input A / B, External device monitoring input Vs to Vs – 2.5 V (sink current 5 mA or less): Enabled (Note), Open: Disabled In case of setting the external device monitoring function to “enabled” +24 V DC K1 Receiver K2 (Yellow-green) External device monitoring input (Black) OSSD 1 K1 (White) OSSD 2 K2 K1, K2: External device 0 V * Refer to the SF4B manual for details of the external device monitoring function. Note: Vs is the applying supply voltage. In case of using I/O circuit for NPN output Color code of mating cable Emitter Cable color: Gray The diagram at left shows the configuration when using NPN output, interlock function “disabled (automatic reset)” and external device monitoring function “disabled”. (Brown) +V (Shield) Output polarity setting wire (Yellow) Override input * S1 (Pale purple) Interlock setting input: Open (Pink) Emission halt input / Reset input (Gray) Interference prevention + Uses when the interference prevention function is used (Gray / Black) Interference prevention – (Yellow-green / Black) Auxiliary output * S1 + – 24 V DC ±10 % In case of setting the interlock function to “enabled (manual reset)” • When the interlock function is “enabled (manual reset)”, the override function cannot be used. (Red) Muting lamp output Emitter (Blue) 0 V (Orange) Synchronization + Receiver Cable color: Gray with black line (Pink) Emission halt input / Reset input * S1 (Orange) Synchronization + (Brown) +V K1 (Shield) Output polarity setting wire K2 (Black) OSSD 1 (White) OSSD 2 (Gray) Interference prevention + Uses when the interference prevention function is used (Gray / Black) Interference prevention – (Yellow-green) External device monitoring input (Sky-blue / White) Muting input A * S1 (Sky-blue / Black) Muting input B * S1 (Pale purple) Interlock setting input (Orange / Black) Synchronization – (Orange / Black) Synchronization – (Blue) 0 V * S1 0V * Refer to the SF4B manual for details of the interlock function. In case of setting the external device monitoring function to “enabled” +24 V DC K1, K2: Forcedguided relay or magnet contactor Switch S1 • Emission halt input / Reset input For manual reset 0 to +1.5 V (source current 5 mA or less): Emission halt, Open: Emission For automatic reset 0 to +1.5 V (source current 5 mA or less): Emission, Open: Emission halt • Override input, Muting input A / B, External device monitoring input 0 to +1.5 V (source current 5 mA or less): Enabled, Open: Disabled 26 K1 Receiver K2 (Black) OSSD 1 (White) OSSD 2 (Yellow-green) External device monitoring input K1 K2 0V K1, K2: External device * Refer to the SF4B manual for details of the external device monitoring function. I/O CIRCUIT AND WIRING DIAGRAMS Refer to the manual on our website for details. SF-C11 SF4B series wiring diagram (Control Category 4) When SF-C11 is connected to the light curtain, be sure to use the following mating cable. SFB-CB□, SFB-CCJ□ For PNP output (minus ground) • Set the light curtain input polarity selection switch to the PNP side and ground the 0 V line. Light curtain input polarity selection switch +24 V DC A1 RESET (Note 1) (Note 1) A B (Note 2) X1 X2 X3 F Receiver side connector L1 FUSE1 Terminal FUSE2 13 23 33 41 K1 NPN SF-C11 control circuit PNP Ui Terminal arrangement diagram F.G. OUT AUX 0V T2 TEST (Note 3) INTER_LOCK FAULT T1 KA, KB: Force-guided relay or magnet contactor F.G. 14 24 34 42 L1 L2 L3 KB KA N X1 X2 Reset output terminal Reset input terminal (Manual) KB X3 Reset input terminal (Automatic) KA A T1 2 1 3 SF-C11 control circuit OUT A2 7 4 6 AUX T2 NPN PNP INTER_LOCK Test input terminal AUX Semiconductor auxiliary output Connector pin No. 8 5 Ui Test output terminal T2 Pin layout for light curtain connectors B F Receiver side connector Emitter side connector A Not used B M X3 Auxiliary output (NC contact × 1) X2 RESET A1 0V X1 Light curtain input polarity selection switch For NPN output (plus ground) +24 V DC A2 41-42 Notes: 1) T  he above diagram is when using manual reset. If 3 automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) Emission halt occurs when the test (TEST) button is open, and emission occurs when the test (TEST) button is short-circuited. If not using the test (TEST) button, short-circuit T1 and T2. • In the above diagram, set the light curtain input polarity selection switch to the NPN side and ground the + side. +24 V DC 13-14, 23-24, 33-34 Enabling path (NO contact × 3) K2 Emitter side connector A2 Function A1 FAULT T1 Emitter side connector Receiver side connector 1 Interlock OSSD 2 2 +24 V DC +24 V DC 3 Emission halt OSSD 1 4 Auxiliary output EDM (External relay monitor) 5 Synchronization wire + Synchronization wire + 6 Synchronization wire – Synchronization wire – 7 0V 0V 8 Shield wire Shield wire 0 V TEST SF-C12 SF4B series wiring diagram (Control Category 4) • Set the two light curtain input polarity select switches to the PNP side and connect the FG terminal to the 0 V line. Emission halt input switch (Note) (Note) Interference prevention wire Emitter side connector MPCE1 MPCE2 FUSE PNP FUSE Light curtain input polarity selection switch NPN Receiver side connector X1 X2 T1 T2 E– E+ R– R+ FB1 FB2 FB3 FB4 32 31 24 23 14 13 A1 A2 FG Terminal arrangement diagram Enabling path Auxiliary Power input output 24 V DC ±10 % Note: The above diagram is when using manual reset. If automatic reset is used, connect a normally closed type pushbutton switch between T1 and T2 and leave between X1 and X2 open. Terminal FG A2 A1 13-14, 23-24 31-32 FB4 FB3 FB2 FB1 Function Frame ground (F.G.) terminal 0V +24 V DC Enabling path (NO contact × 2) Auxiliary output (NC contact × 1) External relay monitor terminal 2 External relay monitor terminal 1 • In the above diagram, set the two light curtain input polarity selection switches to the NPN side and connect the F.G. terminal to the + side. Terminal R+ R– E+ E– T2 T1 X2 X1 Function Interference prevention wire – (Receiver side) Interference prevention wire + (Receiver side) Interference prevention wire – (Emitter side) Interference prevention wire + (Emitter side) Emission halt input terminal Automatic reset / manual reset selection terminal Manual reset: X1 – X2 short-circuited Pin layout for light curtain connectors 1 10 2 9 3 12 11 8 For NPN output (plus ground) X1 X2 T1 T2 E– E+ R– R+ FB1 FB2 FB3 FB4 32 31 24 23 14 13 A1 A2 FG When SF-C12 is connected to the light curtain, be sure to use the following maing cable. SFB-CB05-MU, SFB-CCJ□-MU For PNP output (minus ground) 7 6 5 4 Note: Input and output for pin Nos. 11 and 12 are not used by this product. Connector pin No. 1 2 3 4 5 6 7 8 9 10 11 12 Emitter side connector Interlock +24 V DC Emission halt Auxiliary output Synchronization wire + Synchronization wire – 0V Shield wire Interference prevention wire + Interference prevention wire – (Override input) (Muting lamp output) Receiver side connector OSSD 2 +24 V DC OSSD 1 EDM (External relay monitor) Synchronization wire + Synchronization wire – 0V Shield wire Interference prevention wire + Interference prevention wire – (Muting input 1) (Muting input 2) 27 I/O CIRCUIT AND WIRING DIAGRAMS Refer to the manual on our website for details. SF-C13 SF4B series wiring diagram (Control Category 4) For PNP output (minus ground) For NPN output (plus ground) • Connect the light curtain control outputs OSSD 1 and OSSD 2 to S1 and S2 respectively. • Connect the light curtain control outputs OSSD 1 and OSSD 2 to S4 and S2 respectively and ground the + side. (Orange / Black) Synchronization – Emitter Receiver Cable color: Gray with black line Cable color: Gray (Orange) Synchronization + +V (Brown) +24 V DC Output Emission halt Auxiliary output Interlock setting polarity setting wire input / Reset (Yellow-green / input (Pale purple) Black) Open +V (Brown) (Shield) input (Pink) Load 0 V (Blue) 0 V (Blue) (Orange / Black) Synchronization – Emitter (Orange) Synchronization + +V (Brown) +24 V DC Output Emission halt Auxiliary output Interlock setting polarity input / Reset input (Yellow-green / input (Pale purple) setting wire (Pink) Black) Open (Shield) 0V Load +V (Brown) (Blue) Output polarity setting wire (Shield) External device monitoring input (Yellow-green) OSSD 2 (White) OSSD 1 (Black) OSSD 2 (White) L1 L1 A1 S1 S2 S3 (Note 1) FUSE1 S4 X1 X2 X3 F 13 23 (Note 1) FUSE1 FUSE2 33 41 A1 F.G. S1 S2 S3 S4 X1 X2 F K1 Ui A2 0V AUX F.G. KA, KB: Force-guided relay or magnet contactor KA N 33 41 RESET (Note 1,2) K2 FAULT 14 24 FUSE2 SF-C13 control circuit K2 INTER_LOCK X3 13 23 K1 Ui SF-C13 control circuit OUT Output polarity setting wire (Shield) 0 V (Blue) External device monitoring input (Yellow-green) OSSD 1 (Black) RESET (Note 1,2) Receiver Cable color: Gray with black line Cable color: Gray 34 42 L1 L2 L3 KB OUT KB KA M 3 Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. A2 0V AUX INTER_LOCK FAULT 14 24 KA, KB: Force-guided relay or magnet contactor KA N 34 42 L1 L2 L3 KB KA M 3 Notes: 1) T  he above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. Terminal arrangement diagram A1 A2 S1 S2 S3 S4 AUX X1 X2 X3 13 14 23 24 33 34 41 42 28 Terminal Function A1 +24 V DC A2 0V S1 to S4 Light curtain control output (OSSD) input terminal AUX Semiconductor auxiliary output X1 Reset output terminal X2 Reset input terminal (Manual) X3 Reset input terminal (Automatic) 13-14, 23-24, 33-34 Enabling path (NO contact × 3) 41-42 Auxiliary output (NC contact × 1) A terminal block is required for wiring of light curtain side. KB When SF-C13 is connected to the light curtain, be sure to use the following descrete wire mating cable. SFB-CCB□(-MU), SFB-CC□(-MU) I/O CIRCUIT AND WIRING DIAGRAMS Refer to the manual on our website for details. SF-C14EX(-01) SF4B series wiring diagram (Control Category 4) For PNP output (minus ground) • Set the output polarity selection switch to the PNP side and ground the 0 V line. Emergency stop button +24 V DC (Note 1) KA RESET KB (Note 2) (Note 1) KC RESET KD (Note 2) PLC etc. KE RESET KF (Note 2) • When SF-C14EX is connected to the light curtain, be sure to use the following mating cable. SFB-CB□-EX, SFB-CCJ□ • If the NO (Normally Open) contact switch is used as a muting sensor, wire it as shown in the figure below. S3+ S3 S3– S4+ S4 S4– A1 S11 S12 S21 S22 X11 X12 X13 X21 X22 X23 X31 X32 AUX1 AUX2 AUX3 AUX4 IE+ IE– IR+ IR– Receiver side NPN Output polarity connector selection switch PNP SF-C14EX(-01) control circuit • If the emergency stop button is not used, short-circuit between the terminals S11 to S12 and S21 to S22 directly. Emitter side connector A2 S3+ S3 S3– S4+ S4 S4– T1 T2 O1 O2 L1+ L1– L2+ L2– 14 24 34 44 54 64 KB KD KF +V OUT 0 V +V OUT 0 V 0V F.G. KA KC KE Muting sensor 1 (PNP output type) Muting sensor 2 (NPN output type) Override input TEST Muting lamp output 1 3.6 to 30 W 0V Muting lamp output 2 3.6 to 30 W KA to KF: Force-guided relay or magnet contactors. Notes: 1) T  he above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X12 and connect it to X13, and disconnect the lead from X22 and connect it to X23, as shown by the dotted lines. In this case, a reset (RESET) button is not needed. Terminals X31 to X32 are for manual reset only. 2) Use a momentary-type switch for the reset (RESET) button. For NPN output (plus ground) • Set the output polarity selection switch to the NPN side and ground the side of the power supply input. Emergency stop button +24 V DC (Note 1) KA RESET KB (Note 2) (Note 1) KC RESET KD (Note 2) KE RESET KF (Note 2) PLC etc. F.G. A1 S11 S12 S21 S22 X11 X12 X13 X21 X22 X23 X31 X32 AUX1 AUX2 AUX3 AUX4 IE+ IE– IR+ IR– Receiver side NPN Output polarity connector selection switch PNP Emitter side connector SF-C14EX(-01) control circuit A2 S3+ S3 S3– S4+ S4 S4– T1 T2 O1 O2 L1+ L1– L2+ L2– 14 24 34 44 54 64 KB KD KF +V OUT 0 V +V OUT 0 V 0V KA Muting sensor 1 (PNP output type) KC TEST Muting sensor 2 (NPN output type) Override input Terminal arrangement Terminal diagram Muting lamp output 1 3.6 to 30 W Function Muting lamp output 2 3.6 to 30 W Terminal KE +24 V DC KA to KF: Force-guided relay or magnet contactors. Function 14 Enabling path 1, Beam received / Beam S11 Emergency stop 24 interrupted output of the light curtain S12 contact input 2 NC input 34 Enabling path 2, light curtain output S21 Between S11 and S12 44 including the muting function S22 Between S21 and S22 54 X11 Enabling path 1 reset input Enabling path 3 64 Emergency stop output X12 X11 - X12: Manual reset S3+ Muting sensor input 1 X13 X11 - X13: Automatic reset (PNP output type) S3 X21 Enabling path 2 reset input S3+, S3–: Power supply S3– S3: Sensor output X22 X21 - X22: Manual reset S4+ Muting sensor input 2 X23 X21 - X23: Automatic reset S4 S4– T1 T2 O1 O2 (NPN output type) S4+, S4–: Power supply S4: Sensor output Test input terminal Open: Test mode Short-circuit: Normal operation Override input terminal Open: Invalid Short-circuit: Valid X31 Enabling path 3 reset input X32 X31 - X32: Manual reset Connector pin No. 8 7 4 Receiver side connector 1 Interference prevention Interference prevention wire + wire + 2 +24 V DC 3 Interference prevention Interference prevention wire – wire – 4 Auxiliary output Not used Synchronization wire + Synchronization wire – Synchronization wire + Synchronization wire – 6 5 Emitter side connector 5 6 +24 V DC 0V 0V 8 Shield wire Shield wire AUX3 Auxiliary output 3, Blown lamp output AUX4 Auxiliary output 4, Light curtain auxiliary output IR+ Interference prevention terminal, Receiver side + 0V 1 7 L2+ Muting lamp L2– output 2 A2 2 3 AUX2 Auxiliary output 2, Override output IE+ Interference prevention terminal, Emitter side + +24 V DC Pin layout for light curtain connectors AUX1 Auxiliary output 1, Muting output L1+ Muting lamp L1– output 1 A1 Notes: 1) T  he left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X12 and connect it to X13, and disconnect the lead from X22 and connect it to X23, as shown by the dotted lines. In this case, a reset (RESET) button is not needed. Terminals X31 to X32 are for manual reset only. 2) Use a momentary-type switch for the reset (RESET) button. IE– Interference prevention terminal, Emitter side – IR– Interference prevention terminal, Receiver side – 29 PRECAUTIONS FOR PROPER USE Interlock function • The selection of manual reset / automatic reset is available by applying the interlock input wiring. The interlock becomes available by selecting manual reset. (Refer to the SF4B manual for details.) Emission halt function • This function stops the emission process of the emitter. You can select whether emission is on or halted by means of the connection status for the emission halt input / reset input wire (pink). • During emission halt, the control outputs (OSSD 1, OSSD 2) become OFF status. • By using this function, malfunction due to extraneous noise or abnormality in the control outputs (OSSD 1, OSSD 2) and the auxiliary output can be determined even from the machinery side. • Normal operation is restored when the emission halt input / reset input wire (pink) is connected to 0 V or +V. (Refer to the SF4B manual for details.) Auxiliary output (Non-safety output) • This light curtain incorporates the auxiliary output (yellowgreen / black) for the non-safety output. The auxiliary output is incorporated with the emitter. (Refer to the SF4B manual for details.) External device monitoring function • This is the function for checking whether the external safety relay connected to the control outputs (OSSD 1, OSSD 2) perform normally in accordance with the control outputs (OSSD 1, OSSD 2) or not. Monitor the contacting point “b” of the external safety relay, and if any abnormality such as deposit of the contacting point, etc. is detected, change the status of the light curtain into lockout one, and turn OFF the control outputs (OSSD 1, OSSD 2). (Refer to the SF4B manual for details.) Muting function • This function turns the safety function of this light curtain into disabled temporarily. When the control outputs (OSSD 1, OSSD 2) are ON, this function is available for passing the workpiece through the sensing area of the light curtain without stopping the machinery. The muting function becomes valid when all the conditions listed below are satisfied. However, this function connot be used with the SF4B-□-03. 1 The control outputs (OSSD 1, OSSD 2) shall be ON. 2 The incandescent lamp with 3 to 10 W shall be connected to the muting lamp output (red). 3 The output of the muting sensors A and B shall be changed from OFF (open) to ON. At this time, the time difference occurred by changing the output of the muting sensors A and B into ON status shall be within 0.03 to 3 sec. • The following devices, photoelectric sensor with semiconductor output, inductive proximity sensor, position switch on N.O. (Normally open) contact, etc. are available for applying to the muting sensor. • In case of using the muting function, please order 12-core cable. (Refer to the SF4B manual for details.) 30 Refer to the manual on our website for details. Override function • This function sets the safety function of this light curtain enabled forcibly. When using the muting function, the override function can be used to start the machinery at times such as when the control outputs (OSSD 1 and OSSD 2) are OFF or when the muting sensors are ON when the line is to be started. The override function becomes valid when all the conditions listed below are satisfied. However, this function cannot be used with the SF4B-□-03. (Refer to the SF4B manual for details.) Series connection Connectable up to 3 sets of light curtains (however, 192 beam channels max.) (Refer to the SF4B manual for details.) Parallel connection Connectable up to 3 sets of light cartains (Refer to the SF4B manual for details.) Series and parallel mixed connection Connectable up to 3 sets of light curtains (however, 192 beam channels max.) (Refer to the SF4B manual for details.) Wiring Refer to the applicable regulations for the region where this device is to be used when setting up the device. In addition, make sure that all necessary measures are taken to prevent possible dangerous operating errors resulting from earth faults. • Make sure to carry out the wiring in the power supply off condition. • Verify that the supply voltage variation is within the rating. • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground. • Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Part description and function • (Refer to the SF4B manual for details.) Others • Do not use during the initial transient time (2 sec.) after the power supply is switched on. • Avoid dust, dirt and steam. • Take care that the light curtain does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. • Take care that the light curtain is not directly exposed to fluorescent light from a rapid-starter lamp or a high frequency lighting device, as it may affect the sensing performance. PRECAUTIONS FOR PROPER USE • When this device is used in the “PSDI mode”, an appropriate control circuit must be configured between this device and the machinery. For details, be sure to refer to the standards or regulations applicable in each region or country. • To use this product in the U.S.A., refer to OSHA 1910. 212 and OSHA 1910. 217 for installation, and in Europe, refer to EN ISO 13855 as well. Observe your national and local requirements before installing this product. Refer to the manual on our website for details. Safety distance • Calculate the safety distance correctly, and always maintain a distance which is equal to or greater than the safety distance, between the sensing area of this light curtain and the dangerous parts of the machinery. (Please check the latest standards for the equation.) If the safety distance is miscalculated or if sufficient distance is not maintained, there is a danger of serious injury or death. • Before designing the system, refer to the relevant standards of the region where this device is to be used and then install this device. Also, the below calculation is valid only when the intrusion direction is perpendicular to the sensing area. In case the intrusion direction is not perpendicular to the sensing area, be sure to refer to the relevant standard (regional standard, specification of the machine, etc.) for details of the calculation. • This catalog is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use. • Both emitter and receiver are combined adjusted on factory setting, please apply both emitter and receiver with the same serial No. The serial No. is indicated on the plates of both emitter and receiver. (Indicated under model No.) • Make sure to carry out the test run before regular operation. • This safety system is for use only on machinery in which the dangerous parts can be stopped immediately, either by an emergency stop unit or by disconnecting the power supply. Do not use this system with machinery which cannot be stopped at any point in its operation cycle. Dangerous part of machine Emitter S Beam axis Receiver S: Safety distance Sensing area • Make sure to install this product such that any part of the human body must pass through its sensing area in order to reach the dangerous parts of the machinery. If the human body is not detected, there is a danger of serious injury or death. • Do not use any reflective type or retroreflective type arrangement. • Furthermore, facing several receivers towards one emitter, or vice versa, could produce a non‑sensing area or cause mutual interference, which may result in serious injury or death. Sensing area Size of minimum sensing object when applying floating blanking function Min. sensing object when applying floating blanking function Setting (Note) Invalid 1 beam channel 2 beam channels 3 beam channels SF4B-F□(G) (Min. sensing object ø14 mm ø0.551 in) ø14 mm ø0.551 in ø24 mm ø0.945 in ø34 mm ø1.339 in ø44 mm ø1.732 in SF4B-H□(G) (Min. sensing object ø25 mm ø0.984 in) ø25 mm ø0.984 in ø45 mm ø1.772 in ø65 mm ø2.559 in ø85 mm ø3.346 in SF4B-A□(G) (Min. sensing object ø45 mm ø1.772 in) ø45 mm ø1.772 in ø85 mm ø3.346 in ø125 mm ø4.921 in ø165 mm ø6.496 in Correct mounting method Dangerous part The sizes of the minimum sensing objects for this device vary depending on whether or not the floating blanking function is being used. Calculate the safety distance with the proper size of the minimum sensing object and appropriate equation. Protective structure Note: R  efer to p.10 for details of the floating blanking function. However, the floating blanking function cannot be used with the SF4B-□-01, the SF4B-□-03 and SF-C14EX-01. For use in Europe (EU) (as EN ISO 13855)] (Also applicable to ISO 13855 / JIS B 9715) For intrusion direction perpendicular to the sensing area Dangerous part Sensing area Wrong mounting method Dangerous part Sensing area Dangerous part Sensing area • Equation 1 S=K×T+C S: Safety distance (mm) Minimum required distance between the sensing area surface and the dangerous parts of the machine K: Intrusion velocity of operator’s body or object (mm/sec.) Normally taken as 2,000 (mm/sec.) for calculation T: R  esponse time of total equipment (sec.) T = Tm + TSF4B Tm: Maximum halting time of machinery (sec.) TSF4B: Response time of the SF4B series (sec.) C: Additional distance calculated from the size of the minimum sensing object of the light curtain (mm) However, the value of “C” cannot be less than 0. C = 8 × (d – 14) d: Minimum sensing object diameter (mm) 31 PRECAUTIONS FOR PROPER USE • For calculating the safety distance “S”, there are the following five cases. First calculate by substituting the value K = 2,000 (mm/sec.) in the equation above. Then, classify the obtained value of “S” into three cases, 1) S < 100, 2) 100 ≤ S ≤ 500, and 3) S > 500. For Case 3) S > 500, recalculate by substituting the value K = 1,600 (mm/ sec.). After that, classify the calculation result into two cases, 4) S ≤ 500 and 5) S > 500. For details, refer to the instruction manual enclosed with this product. For calculating “Tm” (maximum halt time of the machinery), use a special device called a “brake monitor”. When this device is used in the “PSDI mode”, an appropriate safety distance “S” must be calculated. For details, be sure to refer to the standards or regulations applicable in each region or country. • Equation S=K×T+C S: Safety distance (mm) K: Intrusion velocity of operator’s body or object (mm/sec.) Taken as 1,600 (mm/sec.) for calculation T: R  esponse time of total equipment (sec.) T = Tm + TSF4B Tm: Maximum halting time of machinery (sec.) TSF4B: Response time of the SF4B series (sec.) C: Additional distance calculated from the size of the minimum sensing object of the light curtain (mm) C = 850 (mm) (Constant) For use in the United States of America (as per ANSI B11.19) • Equation 2 S = K× (TS + TC + TSF4B + Tbm) + Dpf S: S  afety distance (mm) Minimum required distance between the sensing area surface and the dangerous parts of the machine K: Intrusion velocity {Recommended value in OSHA is 63 (inch/sec.) ≈ 1,600 (mm/sec.)} ANSI B11.19 does not define the intrusion velocity “K”. When determining “K”, consider possible factors including physical ability of operators. TS: Halting time calculated from the operation time of the control element (air valve, etc.) (sec.) TC: Maximum response time of the control circuit required for functioning the brake (sec.) TSF4B: Response time of light curtain (sec.) Tbm: Additional halting time tolerance for the brake monitor (sec.) The following equation holds when the machine is equipped with a brake monitor. Tbm = Ta – (Ts + Tc) Ta: Setting time of brake monitor (sec.) When the machine is not equipped with a brake monitor, it is recommended that 20 % or more of (Ts + Tc) is taken as additional halting time. Dpf: Additional distance calculated from the size of the minimum sensing of the SF4B-F□(G): Dpf = 23.8 mm 0.937 in SF4B-H□(G□): Dpf = 61.2 mm 2.409 in SF4B-A□(G): Dpf = 129.2 mm 5.087 in Dpf =  3.4 × (d – 0.276) (inch) ≈ 3.4 × (d – 7) (mm) d: Minimum sensing object diameter 0.552 (inch) ≈ 14 (mm) SF4B-F□(G) Minimum sensing object diameter 0.985 (inch) ≈ 25 (mm) SF4B-H□(G□) Minimum sensing object diameter 1.772 (inch) ≈ 45 (mm) SF4B-A□(G) Output waveform [Control outputs (OSSD 1, OSSD 2) ON] • Refer to the SF4B manual for details. Influence of reflective surfaces • Refer to the SF4B manual for details. 32 Refer to the manual on our website for details. Handy-controller This device enables to set each function using the handy-controller SFB-HC (optional). (However, a handy-controller cannot be used with the SF4B-□-01, the SF4B-□-03 and the SF-C14EX-01.) Among the functions, the contents related to the safety distance such as the size of the minimum sensing object and response time are varied depending on the setting condition. When setting each function, re-calculate the safety distance, and make enough space larger than the calculated safety distance. Failure to do so might cause the accident that the device cannot stop quickly before reaching the dangerous area of the machinery, resulting in the serious injury or death. • Refer to the instruction manual enclosed with the handy-controller for details of the function settings for using handy-controller SFB-HC (optional). Troubleshooting • Refer to the SF4B manual for details. Corner mirror • Be sure to carry out maintenance while referring to the instruction manual for the SF4B series of light curtains. • Do not use if dirt, water, or oil, etc. is attached to the reflective surface of this product. Appropriate sensing range may not be maintained due to diffusion or refraction. • Make sure that you have read the instruction manual for the corner mirror thoroughly before setting up the corner mirrors and light curtains, and follow the instructions given. If the equipment is not set up correctly as stipulated in the instruction manual, incident light errors may result in unexpected situations which may result in serious injury or death. • Please download the instruction manuals from our website. • Light curtain SF4B series cannot be used as a retroreflective type. Avoid installing the light curtain as a retroreflective type when this product is applied. • The mirror part of this product is made of glass. Note that if it is broken, the glass shards may fly apart. • Do not use if crack or breakage appears on the reflective surface of this product. Proper sensing range may not be maintained due to diffusion or refraction. If crack or breakage appears on the reflective surface of this product, replace the product. • When adjusting beam channels with a laser alignment tool, etc., take sufficient care that the laser beam reflected by this product does not enter the eyes. • Failure to follow the above items may result in death or serious injury. DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. SF4B-□ Not available for the robust type SF4B-□G□ Light curtain Assembly dimensions Mounting drawing for the light curtains using the standard mounting brackets MS-SFB-1 (optional) and the intermediate supporting brackets. 43 1.693 42 1.654 30 1.181 15 0.591 28 1.102 18 0.709 5.5 0.217 28 1.102 18 0.709 5.5 0.217 42 1.654 30 1.181 15 0.591 5.5 1.5 0.217 0.059 50 1.969 43 1.693 30 1.181 18 0.709 5.5 0.217 5.5 0.217 1.5 0.059 50 1.969 5.5 0.217 Display section G 19 0.748 H 5 0.197 50 1.969 86.6 E 3.409 2 0.079 D 70.5 2.776 5 0.197 Emitter BC A SF4B-F39□ SF4B-H20□ SF4B-A10□ SF4B-F47□ SF4B-H24□ SF4B-A12□ SF4B-F55□ SF4B-H28□ SF4B-A14□ SF4B-F63□ SF4B-H32□ SF4B-A16□ SF4B-F71□ SF4B-H36□ SF4B-A18□ SF4B-F79□ SF4B-H40□ SF4B-A20□ SF4B-F95□ SF4B-H48□ SF4B-A24□ SF4B-F111□ SF4B-H56□ SF4B-A28□ SF4B-F127□ SF4B-H64□ SF4B-A32□ – SF4B-H72□ SF4B-A36□ – SF4B-H80□ SF4B-A40□ – SF4B-H88□ SF4B-A44□ – SF4B-H96□ SF4B-A48□ 34.2 1.346 70.5 2.776 5 0.197 G 70.5 2.776 H 5 0.197 Emitter 230 9.055 310 12.205 390 15.354 470 18.504 550 21.654 630 24.803 710 27.953 790 31.102 950 37.402 1,110 43.701 1,270 50.000 1,430 56.299 1,590 62.598 1,750 68.898 1,910 75.197 SF4B-F□01 SF4B-A□-01 SF4B-H□01 220 8.661 300 11.811 380 14.960 460 18.110 540 21.260 620 24.409 700 27.559 780 30.708 940 37.007 1,100 43.701 1,260 49.606 1,420 55.905 1,580 62.205 1,740 68.504 1,900 74.803 200 7.874 280 11.024 360 14.173 440 17.323 520 20.472 600 23.622 680 26.772 760 29.921 920 36.220 1,080 42.520 1,240 48.819 1,400 55.118 1,560 61.417 1,720 67.716 1,880 74.016 F 50 1.969 E 86.6 3.409 2 0.079 D 34.2 1.346 Receiver Mounting Total Intermediate supporting pitch length bracket mounting pitch A’ (Note) A SF4B-F31□ SF4B-H16□ SF4B-A8□ 2 0.079 D Display section 86.6 3.409 Receiver Model No. SF4B-F23□ SF4B-H12□ SF4B-A6□ 50 1.969 E 50 1.969 AC B Display section 19 0.748 Protective height 5.5 0.217 28 1.102 F F 50 1.969 E 2 0.079 D 30 1.181 18 0.709 5.5 0.217 1.5 0.059 Display section F 43 1.693 27 1.063 50 1.969 50 1.969 50 1.969 C BA A BC 28 1.102 28 1.102 14 0.551 1.5 0.059 30 1.181 50 1.969 70.5 2.776 28 1.102 28 1.102 14 0.551 50 1.969 30 28 1.181 1.102 86.6 3.409 27 1.063 43 1.693 Beam pitch First beam channel position G H Model No. B C 270 10.630 350 13.780 430 16.929 510 20.079 590 23.228 670 26.378 750 29.528 830 32.677 990 38.976 1,150 45.276 1,310 51.575 1,470 57.874 1,630 64.173 1,790 70.472 1,950 76.772 286 11.260 366 14.406 446 17.559 526 20.709 606 23.858 686 27.008 766 30.157 846 33.307 1,006 39.606 1,166 45.905 1,326 52.505 1,486 58.504 1,646 64.803 1,806 71.102 1,966 77.401 D E F - - - SF4B-F□ - - - SF4B-H□ - - - SF4B-A□ - - - - - - - - - - - - - - - - - - 390 15.354 470 18.504 550 21.654 418 16.457 472 18.583 525 20.669 433 17.047 473 18.622 10 0.394 20 0.787 40 1.575 5 0.197 5 0.197 15 0.591 842 33.150 948 37.323 1,055 41.535 870 1,308 34.252 51.496 950 1,428 37.402 56.220 Note: When SF4B-□-01 is used for China press machine as a safety device, the distance between the center of the 1st beam axis and the center of the last beam axis is regarded as protective height A’. 33 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. SF4B-□ Not available for the robust type SF4B-□G□ Light curtain Assembly dimensions Mounting drawing for the light curtains using the dead zoneless brackets MS-SFB-3 (optional) and the intermediate supporting brackets. 43 1.693 34 1.339 50 1.969 42 1.654 3 15 0.591 0.118 21 0.827 26 1.024 1.5 3 0.118 0.059 50 1.969 30 1.181 28 1.102 25 0.984 5.5 0.217 5.5 0.217 50 1.969 KJ A Display section Display section L 19 0.748 50 1.969 14.5 0.571 Emitter 38 1.496 SF4B-F39□ SF4B-H20□ SF4B-A10□ SF4B-F47□ SF4B-H24□ SF4B-A12□ SF4B-F55□ SF4B-H28□ SF4B-A14□ SF4B-F63□ SF4B-H32□ SF4B-A16□ SF4B-F71□ SF4B-H36□ SF4B-A18□ SF4B-F79□ SF4B-H40□ SF4B-A20□ SF4B-F95□ SF4B-H48□ SF4B-A24□ SF4B-F111□ SF4B-H56□ SF4B-A28□ SF4B-F127□ SF4B-H64□ SF4B-A32□ – SF4B-H72□ SF4B-A36□ – SF4B-H80□ SF4B-A40□ – SF4B-H88□ SF4B-A44□ – SF4B-H96□ SF4B-A48□ 14.5 38 H0.571 1.496 230 9.055 310 12.205 390 15.354 470 18.504 550 21.654 630 24.803 710 27.953 790 31.102 950 37.402 1,110 43.701 1,270 50.000 1,430 56.299 1,590 62.598 1,750 68.898 1,910 75.197 SF4B-F□01 SF4B-A□-01 SF4B-H□01 220 8.661 300 11.811 380 14.960 460 18.110 540 21.260 620 24.409 700 27.559 780 30.708 940 37.007 1,100 43.701 1,260 49.606 1,420 55.905 1,580 62.205 1,740 68.504 1,900 74.803 200 7.874 280 11.024 360 14.173 440 17.323 520 20.472 600 23.622 680 26.772 760 29.921 920 36.220 1,080 42.520 1,240 48.819 1,400 55.118 1,560 61.417 1,720 67.716 1,880 74.016 50 1.969 N 50 1.969 M L 19 0.748 Receiver Intermediate supporting bracket mounting pitch Beam pitch First beam channel position G H Model No. J K 209 8.228 289 11.378 369 14.528 449 17.677 529 20.827 609 23.976 689 27.126 769 30.276 929 36.575 1,089 42.874 1,249 49.173 1,409 55.472 1,569 61.772 1,729 68.071 1,889 74.370 201 7.913 281 11.063 361 14.213 441 17.362 521 20.512 601 23.661 681 26.811 761 29.961 921 36.260 1,081 42.559 1,241 48.858 1,401 55.157 1,561 61.457 1,721 67.756 1,881 74.055 L M N - - - SF4B-F□ - - - SF4B-H□ - - - SF4B-A□ - - - - - - - - - - - - - - - - - - 370 14.567 450 17.717 530 20.866 398 15.669 452 17.795 505 19.882 413 16.260 453 17.835 822 32.362 928 36.535 1,035 40.748 850 1,288 33.465 50.709 930 1,408 36.614 55.433 Note: When SF4B-□-01 is used for China press machine as a safety device, the distance between the center of the 1st beam axis and the center of the last beam axis is regarded as protective height A’. 34 50 5.5 1.969 0.217 2 0.079 34.2 1.346 14.5 0.571 38 1.496 A’ (Note) A 3 0.118 70.5 2.776 70.5 2.776 G 30 1.181 3 0.118 21 0.827 26 1.024 Display section Emitter MS-SFB-3 Mounting pitch 25 14 0.551 0.984 50 1.969 43 1.693 86.6 3.409 86.6 3.409 Receiver Model No. SF4B-F31□ SF4B-H16□ SF4B-A8□ 19 0.748 27 1.063 A JK Display section L 19 0.748 Protective height SF4B-F23□ SF4B-H12□ SF4B-A6□ KJ A 50 1.969 M 70.5 2.776 28 1.102 33 1.299 5.5 0.217 1.5 0.059 N 86.6 3.409 L G 38 H 14.5 1.496 0.571 50 1.969 N 28 1.102 33 1.299 14 0.551 5.5 0.217 1.5 0.059 50 1.969 5.5 0.217 2 0.079 34.2 1.346 50 1.969 AJ K 27 1.063 30 1.181 25 0.984 3 0.118 5.5 50 1.969 0.217 2 0.079 19 0.748 5.5 0.217 50 86.6 1.969 3.409 M 70.5 2.776 3 0.118 21 0.827 26 1.024 3 0.118 1.5 0.059 28 1.102 N 50 1.969 43 1.693 50 1.969 43 42 1.693 34 28 1.102 1.654 1.339 15 3 25 0.984 0.118 0.591 21 0.827 26 1.024 10 0.394 20 0.787 40 1.575 5 0.197 5 0.197 15 0.591 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. SF4B-□G□ It is only available for the robust SF4B-□G□ Light curtain Assembly dimensions Mounting drawing for light curtains using the standard mounting brackets MS-SF4BG-1 (optional) and the intermediate supporting brackets. 34.5 1.358 36 1.417 18 0.709 15 0.591 55.5 2.185 42 1.654 4 0.158 55.5 5 2.185 0.197 4 0.158 5 0.197 10 0.394 45 1.772 6 0.236 46 1.811 6 0.236 5.4 0.213 5.4 0.213 6 EDCB A 0.236 G F M 46 J1.811 6 0.236 5.4 0.213 H N 45 1.772 57 2.244 10 0.394 5.4 5.4 0.213 0.213 9 9 0.354 0.354 6.5 0.256 8 0.315 9 0.354 K 6 0.236 5.4 0.213 5.4 0.213 6.5 0.256 8 0.315 6 0.236 A BCDE 46 G 1.811J 46 J1.811 6 0.236 5.4 0.213 K 5.4 0.213 5.4 0.213 6 0.236 6 0.236 6.5 0.256 8 0.315 5.4 0.213 6 0.236 F M H 6 0.236 5.4 0.213 H N Emitter 57 2.244 4 0.158 5.4 45 1.772 0.213 9 0.354 9 0.354 6.5 0.256 8 0.315 B CDE E DCB A A 6.5 0.256 F 8 0.315 N Beam pitch Mounting pitch F M M K 55.5 2.185 42 1.654 55.5 2.185 6 0.236 46 1.811 6.5 0.256 6 0.236 9 G 0.354 L 6 0.236 6.5 0.256 6 0.236 5.4 0.213 5.4 0.213 8 0.315 9 0.354 G L 46 1.811J 5.4 0.213 8 0.315 H K N 42 1.654 Emitter Protective height 55.5 5 0.197 2.185 10 0.394 45 1.772 Receiver Model No. 34.5 1.358 10 0.394 5.5 24 0.217 0.945 45 1.772 57 2.244 34.5 1.358 36 1.417 36 1.417 18 0.709 18 0.709 15 0.591 15 0.591 57 2.244 4 0.158 5 0.197 55.5 2.185 46 1.811 46 1.811 9 0.354 L L 6.5 0.256 8 0.315 45 1.772 6 0.236 5.5 5.5 0.217 0.217 Beam pitch 34.5 1.358 36 1.417 18 0.709 15 0.591 42 1.654 5.5 0.217 24 0.945 Receiver Total length Intermediate supporting bracket mounting pitch A (Note) SF4B-F□G SF4B-A□G SF4B-H□G□ B C D E F G H J K L SF4B-F23G SF4B-H12G□ SF4B-A6G 220 8.661 200 7.874 244 9.606 279 10.984 313 12.323 334 13.150 - - - - - - SF4B-F31G SF4B-H16G□ SF4B-A8G 300 11.811 280 11.024 324 12.756 359 14.134 393 15.472 414 16.299 - - - - - - SF4B-F39G SF4B-H20G□ SF4B-A10G 380 14.961 360 14.173 404 15.906 439 17.283 473 18.622 494 19.449 - - - - - - SF4B-F47G SF4B-H24G□ SF4B-A12G 460 18.110 440 17.323 484 19.055 519 20.433 553 21.772 574 22.598 - - - - - - SF4B-F55G SF4B-H28G□ SF4B-A14G 540 21.260 520 20.472 564 22.205 599 23.583 633 24.921 654 25.748 - - - - - - SF4B-F63G SF4B-H32G□ SF4B-A16G 620 24.409 600 23.622 644 25.354 679 26.732 713 28.071 734 28.898 - - - - - - SF4B-F71G SF4B-H36G□ SF4B-A18G 700 27.559 680 26.772 724 28.504 759 29.882 793 31.220 814 32.047 - - - - - - SF4B-F79G SF4B-H40G□ SF4B-A20G 780 30.709 760 29.921 804 31.654 839 33.031 873 34.370 894 35.197 441 17.362 - 414 16.299 - 419 16.496 - SF4B-F95G SF4B-H48G□ SF4B-A24G 940 37.008 920 36.220 964 37.953 999 39.331 1,033 40.669 1,054 41.496 521 20.512 - 494 19.449 - 499 19.646 - SF4B-F111G SF4B-H56G□ SF4B-A28G 1,100 43.307 1,080 42.520 1,124 44.252 1,159 45.630 1,193 46.968 1,214 47.795 601 23.661 - 574 22.598 - 579 22.795 - SF4B-F127G SF4B-H64G□ SF4B-A32G 1,260 49.606 1,240 48.819 1,284 50.551 1,319 51.929 1,353 53.268 1,374 54.094 681 26.811 - 654 25.748 - 659 25.945 - - SF4B-H72G□ SF4B-A36G 1,420 55.905 1,400 55.118 1,444 56.850 1,479 58.228 1,513 59.567 1,534 60.394 520 20.472 1,001 39.409 493 19.409 974 38.346 498 19.606 979 38.543 - SF4B-H80G□ SF4B-A40G 1,580 62.205 1,560 61.417 1,604 63.150 1,639 64.528 1,673 65.866 1,694 66.693 573 22.559 1,108 43.622 546 21.496 1,081 42.559 551 21.693 1,086 42.756 - SF4B-H88G□ SF4B-A44G 1,740 68.504 1,720 67.716 1,764 69.449 1,799 70.827 1,833 72.165 1,854 72.992 627 24.685 1,215 47.835 600 23.622 1,188 46.772 605 23.819 1,193 46.968 - SF4B-H96G□ SF4B-A48G 1,900 74.803 1,880 74.016 1,924 75.748 1,959 77.126 1,993 78.464 2,014 79.291 680 26.772 1,321 52.008 653 25.709 1,294 50.945 658 25.906 1,289 50.748 Note: When SF4B-□G□ is used for China press machine as a safety device, the distance between the center of the 1st beam axis and the center of the last beam axis is regarded as protective height described in column A. Beam pitch First beam channel position M N SF4B-F□G 10 0.394 11.8 0.465 SF4B-H□G□ 20 0.787 11.8 0.465 SF4B-A□G 40 1.575 21.8 0.858 Model No. 35 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. SF4B-□G□ It is only available for the robust SF4B-□G□ Light curtain Assembly dimensions Mounting drawing for light curtains using the Dead zoneless mounting brackets MS-SF4BG-3 (optional) and the intermediate supporting brackets. 9 0.354 55.5 2.185 42 1.654 6 0.236 34.5 1.358 55.5 2.185 42 1.654 9 0.354 10.5 0.413 6 0.236 5.4 0.213 6 0.236 55.5 2.185 42 1.654 8 0.315 6.7 0.264 55.5 2.185 42 1.654 9 0.354 8 0.315 6.5 0.256 C G 8 0.315 6.5 0.256 6 0.236 6 0.236 46 1.811 9 0.354 5.4 0.213 C 5.4 0.213 8 0.315 6.5 0.256 6 0.236 J C E E A B B A 5.4 H 0.213 5.4 0.213 9 103 0.354 4.055 16 0.630 D Beam pitch K 5.3 107 0.209 4.213 34.3 1.350 48 1.890 L 34.5 1.358 68.8 2.709 ( K 6 0.236 6 0.236 J 46 1.811 5.4 0.213 H 5.4 0.213 34.3 1.350 ( 46 1.811 P 6 0.236 6 0.236 5.4 0.213 5.4 0.213 9 0.354 6.5 0.256 C Model No. E BA AB E 5.4 0.213 8 0.315 6.5 C 0.256 9 0.354 N 9 0.354 9 0.354 103 4.055 5.4 0.213 6 0.236 5.4 T 0.213 6 50.5 0.236 1.988 R Beam pitch D D K 9 0.354 K 53 2.087 34.5 1.358 L 68.8 ) (2.709 34.3 1.350 34.3 1.350 L 68.8 ) (2.709 Emitter Mounting pitch U 5.4 6 0.236 C 0.213 6 46 0.236 1.811 S 6.5 0.256 8 0.315 M 50.5 1.988 5.4 0.213 5.4 6 0.236 0.213 6 46 0.236 1.811 6.5 0.256 Receiver Protective height 6 0.236 9 0.354 6.7 0.264 8 0.315 48 1.890 ) Emitter 5.4 0.213 6.7 34.3 0.264 1.350 48 1.890 8 0.315 Receiver Intermediate supporting bracket mounting pitch A (Note) SF4B-F□G SF4B-A□G SF4B-H□G□ B C D E F G H J M N P Q R S T U SF4B-F23G SF4B-H12G□ SF4B-A6G 220 8.661 200 7.874 244 9.606 64.5 2.539 - - - - - - - - - - - - - - SF4B-F31G SF4B-H16G□ SF4B-A8G 300 11.811 280 11.024 324 12.756 144.5 5.689 - - - - - - - - - - - - - - SF4B-F39G SF4B-H20G□ SF4B-A10G 380 14.961 360 14.173 404 15.906 224.5 8.839 - - - - - - - - - - - - - - SF4B-F47G SF4B-H24G□ SF4B-A12G 460 18.110 440 17.323 484 19.055 304.5 11.988 - - - - - - - - - - - - - - SF4B-F55G SF4B-H28G□ SF4B-A14G 540 21.260 520 20.472 564 22.205 384.5 15.138 - - - - - - - - - - - - - - SF4B-F63G SF4B-H32G□ SF4B-A16G 620 24.409 600 23.622 644 25.354 464.5 18.287 - - - - - - - - - - - - - - SF4B-F71G SF4B-H36G□ SF4B-A18G 700 27.559 680 26.772 724 28.504 544.5 21.437 - - - - - - - - - - - - - - SF4B-F79G SF4B-H40G□ SF4B-A20G 780 30.709 760 29.921 804 31.654 624.5 24.587 414 16.299 - 333 13.110 - 288 11.339 - 289 11.378 - 330 12.992 - 383 15.079 - 347 13.661 - SF4B-F95G SF4B-H48G□ SF4B-A24G 940 37.008 920 36.220 964 37.953 784.5 30.886 494 19.449 - 413 16.260 - 368 14.488 - 369 14.528 - 410 16.142 - 463 18.228 - 427 16.811 - SF4B-F111G SF4B-H56G□ SF4B-A28G 1,100 43.307 1,080 42.520 1,124 44.252 944.5 37.185 574 22.598 - 493 19.409 - 448 17.638 - 449 17.677 - 490 19.291 - 543 21.378 - 507 19.961 - SF4B-F127G SF4B-H64G□ SF4B-A32G 1,260 49.606 1,240 48.819 1,284 50.551 1,104.5 43.484 654 25.748 - 573 22.559 - 528 20.787 - 529 20.827 - 570 22.441 - 623 24.528 - 587 23.110 - - SF4B-H72G□ SF4B-A36G 1,420 55.905 1,400 55.118 1,444 56.850 1,264.5 49.783 493 19.409 974 38.346 412 16.220 893 35.157 367 14.449 848 33.386 368 14.488 849 33.425 409 16.102 890 35.039 462 18.189 943 37.126 426 16.772 907 35.709 - SF4B-H80G□ SF4B-A40G 1,580 62.205 1,560 61.417 1,604 63.150 1,424.5 56.083 546 21.496 1,081 42.559 465 18.307 1,000 39.370 420 16.535 955 37.598 421 16.575 956 37.638 462 18.189 997 39.252 515 20.276 1,050 41.339 479 18.858 1,014 39.921 - SF4B-H88G□ SF4B-A44G 1,740 68.504 1,720 67.716 1,764 69.449 1,584.5 62.382 600 23.622 1,188 46.772 519 20.433 1,107 43.583 474 18.661 1,062 41.811 475 18.701 1,063 41.850 516 20.315 1,104 43.465 569 22.402 1,157 45.551 533 20.984 1,121 44.134 - SF4B-H96G□ SF4B-A48G 1,900 74.803 1,880 74.016 1,924 75.748 1,744.5 68.681 653 25.709 1,294 50.945 572 22.520 1,213 47.756 527 20.748 1,168 45.984 528 20.787 1,169 46.024 569 22.402 1,210 47.638 622 24.488 1,263 49.724 586 23.071 1,227 48.307 Beam pitch First beam channel position K L SF4B-F□G 10 0.394 11.8 0.465 SF4B-H□G□ 20 0.787 11.8 0.465 SF4B-A□G 40 1.575 21.8 0.858 Model No. 36 5.4 6 0.213 0.236 8 0.315 Q 6 0.236 5.4 0.213 50.5 1.988 5.3 107 0.209 4.213 57 6 5.4 2.244 0.236 0.213 9 103 0.354 4.055 16 0.630 34.5 1.358 68.8 2.709 ) 5.4 0.213 5.4 0.213 9 0.354 F 24 0.945 5.4 0.213 D L 9 0.354 8 G 0.315 6.5 0.256 6 0.236 46 1.811 9 0.354 24 F 0.945 5.4 0.213 5.4 0.213 C 6 5.4 6 0.236 C 0.236 0.213 6 5.4 6 0.236 0.213 0.236 46 1.811 46 1.811 10.5 0.413 6 5.4 0.213 0.236 9 0.354 50.5 1.988 5.4 0.213 34.5 1.358 8 0.315 6.7 0.264 Note: When SF4B-□G□ is used for China press machine as a safety device, the distance between the center of the 1st beam axis and the center of the last beam axis is regarded as protective height described in column A. DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. SF4B-□ Not available for the robust type SF4B-□G□ Light curtain Protection bar set MC-SFBH-□ assembly dimensions Protection bar set for rear / side mounting MC-SFBH-□-T assembly dimensions Mounting drawing for the light curtain on which the front protection unit (MC-SFBH-□) is mounted. MC-SFBH-□(L) Mounting drawing for the light curtain on which the front protection unit (MC-SFBH-□-T) is mounted. MC-SFBH-□(R) Rear mounting MC-SFBH-□-T(L) D A B C C B A D D A B C 5 0.197 10 0.394 10 0.394 MC-SFBH-□-T(R) 5 0.197 43.5 1.713 57.5 2.264 43 1.693 43.5 1.713 57.5 2.264 72.7 2.862 72.7 2.862 10 0.394 10 0.394 10 0.394 Applicable light curtain model No. MC-SFBH-12(-T) SF4B-F23□ SF4B-H12□ MC-SFBH-16(-T) SF4B-F31□ SF4B-H16□ MC-SFBH-20(-T) SF4B-F39□ SF4B-H20□ MC-SFBH-24(-T) SF4B-F47□ SF4B-H24□ MC-SFBH-28(-T) SF4B-F55□ SF4B-H28□ MC-SFBH-32(-T) SF4B-F63□ SF4B-H32□ MC-SFBH-36(-T) SF4B-F71□ SF4B-H36□ MC-SFBH-40(-T) SF4B-F79□ SF4B-H40□ MC-SFBH-48(-T) SF4B-F95□ SF4B-H48□ MC-SFBH-56(-T) SF4B-F111□ SF4B-H56□ MC-SFBH-64(-T) SF4B-F127□ SF4B-H64□ MC-SFBH-72(-T) – SF4B-H72□ MC-SFBH-80(-T) – SF4B-H80□ MC-SFBH-88(-T) – SF4B-H88□ MC-SFBH-96(-T) – SF4B-H96□ 10 0.394 60.9 2.398 43 1.693 46.9 1.846 73.7 2.902 44.2 1.740 13 Material: Mounting bracket ···Die-cast zinc alloy 13 Protection bar·········Aluminum 0.512 0.512 Two brackets (one pc. each of R type and L type), one protection bar Two pcs. each of M5 (length 16 mm 0.630 in) hexagon-socket-head bolts, M5 (length 20 mm 0.787 in) hexagon-socket-head bolt are attached. Model No. 5 0.197 230 SF4B-A6□ 9.055 310 SF4B-A8□ 12.205 390 SF4B-A10□ 15.354 470 SF4B-A12□ 18.504 550 SF4B-A14□ 21.654 630 SF4B-A16□ 24.803 710 SF4B-A18□ 27.953 790 SF4B-A20□ 31.102 950 SF4B-A24□ 37.402 1,110 SF4B-A28□ 43.701 1,270 SF4B-A32□ 50.000 1,430 SF4B-A36□ 56.299 1,590 SF4B-A40□ 62.598 1,750 SF4B-A44□ 68.898 1,910 SF4B-A48□ 75.197 B C D 279 10.984 359 14.134 439 17.283 519 20.433 599 23.583 679 26.732 759 29.882 839 33.031 999 39.331 1,159 45.630 1,319 51.929 1,479 58.228 1,639 64.527 1,799 70.827 1,959 77.126 296 11.654 376 14.803 456 17.953 536 21.102 616 24.252 696 27.402 776 30.551 856 33.701 1,016 40.000 1,176 46.299 1,336 52.598 1,496 58.898 1,656 65.197 1,816 71.496 1,976 77.795 250 9.843 330 12.992 410 16.142 490 19.291 570 22.441 650 25.591 730 28.740 810 31.890 970 38.189 1,130 44.488 1,290 50.787 1,450 57.087 1,610 63.386 1,770 69.685 1,930 75.984 C B A D E 44.2 1.740 D 10 0.394 A B C 5 0.197 F 73.7 2.902 73.7 2.902 View E 10 0.394 MC-SFBH-□-T(R) 5 0.197 27.7 1.091 60.9 2.398 73.7 2.902 Side mounting MC-SFBH-□-T(L) A 10 0.394 46.9 1.846 10 0.394 10 0.394 27.7 1.091 View F 10 0.394 46.9 1.846 61.9 61.9 2.437 2.437 Material: Mounting bracket ···Cold rolled carbon steel (SPCC) (Trivalent chrome plated) Protection bar········Aluminum 46.9 1.846 Two brackets (one pc. each of R type and L type), one protection bar Two pcs. each of M5 (length 18 mm 0.709 in) hexagon-socket-head bolts, M5 (length 20 mm 0.787 in) hexagon-socket-head bolt are attached. 37 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. RF-SFBH-□ Corner mirror (Optional) 17.5 6 0.689 0.236 18 0.709 6 0.236 t3 t 0.118 29 1.142 t 3 t 0.118 13 26 1.024 0.512 80 3.150 Effective reflective surface 29 1.142 ABC C RF-SFBH-12 246 9.685 326 12.835 406 15.984 486 19.134 566 22.283 646 25.433 726 28.583 806 31.732 966 38.031 1,126 44.331 1,286 50.630 1,446 56.929 1,606 63.228 1,766 69.527 1,926 75.827 298 11.732 378 14.882 458 18.031 538 21.181 618 24.331 698 27.480 778 30.630 858 33.779 1,018 40.079 1,178 46.378 1,338 52.677 1,498 58.976 1,658 65.275 1,818 71.575 1,978 77.874 RF-SFBH-24 ø8.5 ø0.335 18 0.709 6 0.236 17.5 6 0.689 0.236 RF-SFBH-28 F RF-SFBH-32 RF-SFBH-36 E RF-SFBH-40 RF-SFBH-48 ø8.5 ø0.335 ( RF-SFBH-56 ) 46 1.811 72 2.835 RF-SFBH-64 45° 109 ) (4.219 104 ) (4.094 46 28 1.811 1.102 < When mounting at an angle of 45° > MS-SFB-1 B 236 9.291 316 12.441 396 15.591 476 18.740 556 21.890 636 25.039 716 28.189 796 31.339 956 37.638 1,116 43.937 1,276 50.236 1,436 56.535 1,596 62.835 1,756 69.134 1,916 75.433 RF-SFBH-20 D 64 2.520 A RF-SFBH-16 26 13 1.024 0.512 106 4.173 Model No. Standard mounting bracket (Optional) RF-SFBH-72 RF-SFBH-80 RF-SFBH-88 RF-SFBH-96 MS-SFB-1-T 8 0.315 60° 8.2 0.323 18 0.709 28 1.102 30° M5 (length 14 0.551) R16.6 R0.654 28 1.102 R8.5 R0.335 M5 (length 6 0.236) 60° 6.2 0.244 10.8 0.425 6.1 0.240 8.7 0.343 3 0.118 M5 8.1 0.319 11 0.433 9.6 0.378 5 0.197 5.5 0.217 40° 38 Material: SPCC ø25 Four bracket set ø0.984 40° 34.5 1.358 45 1.772 - - - - - - - - - 458 ±50 18.031 ±1.969 538 ±50 21.181 ±1.969 618 ±50 24.331 ±1.969 698 ±50 27.480 ±1.969 538 ±50 21.181 ±1.969 591 ±50 23.268 ±1.969 645 ±50 25.394 ±1.969 698 ±50 27.480 ±1.969 1,018 ±50 40.079 ±1.969 1,125 ±50 44.291 ±1.969 1,231 ±50 48.464 ±1.969 1,338 ±50 52.677 ±1.969 24.5 0.965 30° R8.5 R0.335 M5 (length 6 0.236) 10.8 0.425 15 0.591 M5 (length 14 0.551) 28 27.4 1.102 1.079 R18.4 R0.724 R16.6 R0.654 10 0.394 14 0.551 28 1.102 3 0.118 6.2 0.244 6.1 8.7 0.240 0.343 29 1.142 M5 11 0.433 Four bracket set Four M5 (length 18 mm 0.709 in) hexagon-socket-head bolts are attached. 18 36 0.709 1.417 ø9.8 ø0.386 - Material: Die-cast zinc alloy 2 0.079 55.5 2.185 - Four bracket set Four M5 (length 18 mm 0.709 in) hexagon-socket-head bolts are attached. Standard L mounting bracket (Optional) 15 0.591 - 970 g approx. 1,170 g approx. 1,370 g approx. 1,570 g approx. 1,770 g approx. 1,970 g approx. 2,170 g approx. 2,660 g approx. 3,060 g approx. 3,460 g approx. 3,890 g approx. 4,550 g approx. 4,950 g approx. 5,350 g approx. 5,750 g approx. Material: Die-cast zinc alloy It is only available for the robust SF4B-□G□. 10 0.394 R 10 0.394 5.5 0.217 MS-SF4BG-1 34.5 1.358 17.5 0.689 - R 4-R2.8 R0.110 28 1.102 14 0.551 28 1.102 - Not available for the robust type SF4B-□G□. 3 33 1.299 0.118 15 0.591 R18.4 R0.724 Net weight 272 10.709 352 13.858 432 17.008 512 20.157 592 23.307 672 26.457 752 29.606 832 32.756 992 39.055 1,152 45.354 1,312 51.653 1,472 57.953 1,632 64.252 1,792 70.551 1,952 76.850 8.4 0.331 24.5 0.965 5 0.197 5.5 0.217 F 8 0.315 R4.1 R0.161 (for sensor mounting) 20 15 28 0.787 0.591 1.102 E M8 mounting bracket (Optional) Not available for the robust type SF4B-□G□. 8.4 0.331 3 0.118 D 5.2 0.205 Eight M5 (length: 10 mm 0.394 in) hexagon-socket-head bolts are attached. It is only available for the robust type SF4B-□G□. 8.1 0.319 9.6 0.378 DIMENSIONS (Unit: mm in) MS-SFB-2 The CAD data can be downloaded from our website. Not available for the robust type SF4B-□G□ Intermediate supporting bracket (Accessory for light curtain) 9.5 0.374 5.8 0.228 12 0.472 4-R2.8 0.110 55 (2.165 ) 2 0.079 43 1.693 15 0.591 24.8 0.976 14.8 0.583 5.5 0.217 5.5 0.217 33 1.299 50 1.969 60 2.362 32 1.260 9 0.354 22.2 0.874 M4 (length 12 0.472) 40 1.575 37 1.457 30° 31 28 (1.220 ) (1.102 ) 12.5 0.492 2 0.079 4-R2.8 R0.110 2 0.079 5.5 5.5 0.217 0.217 50 1.969 8.8 0.346 Material: Die-cast zinc alloy MS-SF4BG-2 8.5 0.335 52 2.047 41 1.614 13 0.512 10.5 0.413 Note: T  he intermediate supporting bracket (MS-SFB-2) is enclosed with the following products. The quantity differs depending on the product as shown below: 1 set: SF4B-F□ … Light curtain with 79 to 111 beam channels SF4B-H□ … Light curtain with 40 to 56 beam channels SF4B-A□ … Light curtain with 20 to 28 beam channels 2 sets: S  F4B-F127 SF4B-H□ … Light curtain with 64 to 80 beam channels SF4B-A□ … Light curtain with 32 to 40 beam channels 3 sets: SF4B-H□ … Light curtain with 88 to 96 beam channels SF4B-A□ … Light curtain with 44 to 48 beam channels It is only available for the robust SF4B-□G□. Intermediate supporting bracket (Accessory for light curtain) Rear mounting ø5.4 ø0.213 mounting hole 13 0.512 8.3 0.327 2 0.079 R21.4 R0.843 Side mounting 18 0.709 5.4 0.213 23 0.906 18 0.709 8 0.315 5.4 0.213 8 0.315 23 0.906 56 8 2.205 0.315 32 1.260 9 10 0.354 0.394 26.5 1.043 34.5 1.358 43 1.693 (51.5) (2.028) 9 10 0.354 0.394 5.4 0.213 10.5 0.413 10 0.394 43 (46.1) 34.5 1.693 (1.815) 1.358 8 0.315 9 0.354 ø5.4 ø0.213 mounting hole 18 0.709 9 0.354 10 0.394 26.5 1.043 56 2.205 32 1.260 5.4 0.213 10.5 0.413 (51.5) 43 34.5 1.693 (2.028) 1.358 18 0.709 34.5 1.358 43 1.693 (46.1) (1.815) Material: ‌Cold rolled carbon steel (SPCC) Note: T  he intermediate supporting bracket MS-SF4BG-2 is enclosed with the following products. The quantity differs depending on the product as shown below: 1 set: SF4B-F□G … Light curtain with 79 to 127 beam channels SF4B-H□G□ … Light curtain with 40 to 64 beam channels SF4B-A□G … Light curtain with 20 to 32 beam channels 2 sets: S  F4B-H□G□ … Light curtain with 72 to 96 beam channels SF4B-A□G … Light curtain with 36 to 48 beam channels 39 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. MS-SFB-3 Not available for the robust type SF4B-□G□ Dead zoneless mounting bracket (Optional) Main body 4-R4 6.8 R0.157 0.268 2-R4 4-R2.8 R0.157 R0.110 2-R3.3 R0.130 5.5 0.217 2-M5 19 0.748 15 10.8 50 41.2 25 0.591 0.425 1.969 1.622 0.984 9.5 0.374 55 2.165 9 5 0.354 0.197 34 1.339 2 0.079 8.5 0.335 11.6 0.457 12 0.472 2-M5 12 0.472 20 0.787 59.5 2.343 2-R3 R0.118 8.4 0.331 Mounting adjustment range 23 0.906 17 0.669 Note: T  he finger protection type has a beam pitch of 10 mm 0.394 in, which produces a dead zone. Additional measures will be required, such as using a protection cover. Dead zoneless mounting bracket (Optional) It is only available for the robust SF4B-□G□. 5.4 0.213 68.8 2.709 58.5 2.303 42.5 1.673 34.5 1.358 26.5 1.043 25 0.984 MS-SFB-4 8 0.315 10.5 0.413 5.4 0.213 3 0.118 63.5 2.500 74.5 2.933 85.5 3.366 18 69 7 0.709 2.717 0.276 45.5 1.791 (Sliding range) Material: Die-cast zinc alloy t 3.2 t 0.126 10.5 0.413 5.4 0.213 20° 10° 10° 10.5 0.413 40° 60° Mounting adjustment range 10° 10° hexagon-socket-head bolts [M5 (length 8 mm 0.315 in)] 40 18 0.709 28 1.102 20° Material: Dead zoneless mounting bracket ··· Cold rolled carbon steel (SPCC) (Trivalent chrome plated) Dead zoneless supporting bracket ··· PPS The adjustment range of the light curtain angle is up to ±10 degrees. 10 0.394 60° 18.1 0.713 8 0.315 52.5 2.067 5.5 0.217 ø5.4 ø0.213 62.6 2.465 66.7 2.626 60.5 2.382 50.7 1.996 Pitch adapter bracket (Optional) Not available for the robust type SF4B-□G□ 8.4 0.331 26 1.024 13 0.512 5.4 0.213 43.2 1.701 26.5 1.043 15° 15° The adjustment range of the light curtain angle is up to ±15 degrees. 38 1.496 50 1.969 9 0.354 9.5 0.374 9.5 0.374 R3 R0.118 8.4 0.331 ø5.5 ø0.217 20 0.787 (Note) 26 1.024 Main body 3 0.118 26 1.024 Spacer 3 21 0.118 0.827 MS-SF4BG-3 5.5 0.217 3 0.118 3-R1 R0.039 9 4.5 0.354 0.177 L-shaped mounting 5.5 0.217 M4 (length 10 0.394) 39 1.535 51 2.008 59.5 2.343 68 2.677 26 1.024 17.3 13 0.681 0.512 Four bracket set Four M5 (length 25 mm 0.984 in) hexagon-socket-head bolts and four spacers are attached. 5.5 0.217 38 1.496 4 0.157 Material: Die-cast zinc alloy 26 1.024 34.5 1.358 30° R8.5 R0.335 M5 (length 6 0.236) 15 0.591 M5 (length 14 0.551) R18.4 R0.724 R16.6 R0.654 4-R2.8 R0.110 Four bracket set Four M5 (length 18 mm 0.709 in) hexagon-socket-head bolts are attached. 6.1 10.8 0.240 0.425 6.2 0.244 28 1.102 14 0.551 28 1.102 8.1 0.319 8.7 0.343 4.7 0.185 M5 11 0.433 9.6 0.378 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. MS-SFB-4-T Not available for the robust type SF4B-□G□ M8 pitch adapter bracket (Optional) 8.4 0.331 8 0.315 3 0.118 63.5 78 2.500 3.071 85.5 3.366 18 69 7 0.709 2.717 45.5 0.276 1.791 (Sliding range) 10 0.394 Material: Die-cast zinc alloy 10 0.394 28 1.102 60° R8.5 R0.335 M5 (length 6 0.236) 30° M5 (length 14 0.551) 15 0.591 R18.4 R0.724 28 1.102 R16.6 R0.654 14 0.551 28 1.102 Four bracket set Four M5 (length 18 mm 0.709 in) hexagon-socket-head bolts are attached. 2-R5 R0.197 10.8 0.425 6.1 0.240 8.7 0.343 4.7 0.185 11 0.433 M5 MS-SFB-7-T   MS-SFB-1-T2 (Rear mounting) Not available for the robust type SF4B-□G□ 2-R5 R0.197 Mounting adjustment range 25.25 0.994 15° 10 10 0.394 0.394 27.2 1.071 7.6 0.299 M5 (length 10 0.394) 8.1 0.319 9.6 0.378 M8 rear mounting bracket (Optional)   M8 rear / side mounting brackets set (Optional) 8.5 0.335 40.6 (1.598 ) 6.2 0.244 ( ) 26 1.024 28 1.102 8 0.315 2.3 0.091 29 1.142 15° 17 0.669 The adjustment range of the light curtain angle is up to ±15 degrees. 28 (1.811 ) R20.2 (R0.795 ) M5 Material: Cold rolled carbon steel (SPCC) (Trivalent chrome plated) Four bracket set Four M5 (length 18 mm 0.709 in) hexagon-socket-head bolts are attached. MS-SFB-8-T   MS-SFB-1-T2 (Side mounting) MS-SFB-8-T(R) M5 4 0.157 M8 side mounting bracket (Optional)   M8 rear / side mounting brackets set (Optional) Not available for the robust type SF4B-□G□ MS-SFB-8-T(L) 10.75 0.423 8 0.315 10.75 0.423 8 0.315 10 0.394 29 40.6 (1.598 ) 1.142 10 7.6 0.394 0.299 2-R5 R0.197 ( 28.35 1.116 (14.75 0.581 ) ) 10 0.394 ( ( 10 0.394 ) 7.6 0.299 (14.75 0.581 ) M5 (length 10 0.394) M5 (length 10 0.394) 33.5 1.319 28 1.811 2.3 0.091 15° ) 29 40.6 1.142 1.598 2-R5 R0.197 28.35 1.116 Mounting adjustment range M5 4 0.157 33.5 1.319 2.3 0.091 28 1.811 R20.2 (R0.795 ) 15° The adjustment range of the light curtain angle is up to ±15 degrees. 28 (1.811 ) Material: Cold rolled carbon steel (SPCC) (Trivalent chrome plated) Four bracket (two pcs. each of R type and L type) set Four M5 (length 18 mm 0.709 in) hexagon-socket-head bolts are attached. 41 DIMENSIONS (Unit: mm in) SF-C11 The CAD data can be downloaded from our website. Control unit (Optional) 54.1 2.130 4 0.157 13 0.512 40 1.575 25 0.984 35 1.378 67.3 2.650 46 1.811 23 0.906 48.8 1.921 Control unit (Optional) 127 5.000 80 3.150 30 1.181 2-ø6 ø0.236 2-ø10 ø0.394 6 7 0.276 0.236 11.5 0.453 Receiver side connector 130 5.118 28 114 1.102 4.488 8 0.315 6 0.236 10 0.394 6.5 0.256 80 3.150 100 3.937 ( ) 6.75 0.266 5 0.197 SF-C14EX(-01) Application expansion unit (Optional) 6 0.236 34.5 1.358 35 1.378 67.3 2.650 4 0.157 3 × 5 = 15 3 × 0.197 = 0.591 130 5.118 36.5 1.437 36.5 34.2 1.437 1.346 Control unit (Optional) 4 0.157 81.4 135 3.205 (5.315 ) 6 19.5 0.236 0.768 22 24.5 30.5 0.866 0.965 1.201 Suitable for 35 mm 1.378 in width DIN rail SF-C13 21 0.827 8 0.315 54.1 2.130 40 1.575 Emitter side connector 25 34.1 0.984 1.343 35 1.378 67.3 2.650 91.6 3.606 46 1.811 38.4 1.512 18 18.4 0.709 0.724 23 0.906 6.5 0.256 80 3.150 80.8 3.181 13 0.512 22.5 0.886 11 0.433 5 0.197 Suitable for 35 mm 1.378 in width DIN rail SFB-HC 10 0.394 Handy-controller (Optional) 80 3.150 99 3.898 Suitable for 35 mm 1.378 in width DIN rail 6.5 0.256 ( SFB-WY1 ) Y-shaped connector (Optional) 65 2.559 30 1.181 23 0.906 25.4 1.000 ø6 ø0.236 cables, 0.5 m 1.640 ft long 140 5.512 CANCEL 42 ENTER 66 2.598 22.5 0.886 13.5 0.531 ø9 ø0.354 FUNCTION Receiver side connector 31.1 1.224 13 0.512 130 5.118 10 0.394 13.5 0.531 67.5 2.657 6.5 0.256 Emitter side connector 3 × 6 = 18 3 × 0.236 = 0.709 130 5.118 SF-C12 41 1.614 ø14 45.8 31 ø0.551 1.803 1.220 Net weight: 35 g approx. DIMENSIONS (Unit: mm in) SF-LAT-2N The CAD data can be downloaded from our website. Laser alignment tool (Optional) SF-LAT-4BG Laser alignment tool (Optional) 21 22.2 (0.827 ) 0.874 ø12 ø0.472 (21) 22 (0.827) 0.866 Center of beam axis 66.5 2.618 Center of beam axis 18.75 0.738 28 1.102 20 0.787 5.3 0.209 48 1.890 92 3.622 ø12 ø0.472 31 1.220 20 0.787 66.5 2.618 1 0.039 15.8 0.622 62 2.441 92 3.622 It is not available for the robust SF4B-□G□. SF-IND-2 48 1.890 28 1.102 38 1.496 28 1.102 It is only available for the robust SF4B-□G□. Large display unit for light curtain (Optional) 22.8 0.898 18.3 0.720 25 0.984 35.5 40.1 1.398 23 1.579 0.906 4.6 0.181 18 0.709 28 1.102 5.5 0.217 ø3.6 ø0.142 cable, 3m 9.843 ft long 25.4 1.000 t 1.6 t 0.063 6.6 0.260 10.4 0.409 Material: Bracket ··· C  old rolled carbon steel (SPCC)(Black chromate) Enclosure ··· POM Cover ··· Polycarbonate 43 : 2015 No. CE-SF4BV2-3A-4 April, 2015
RF-SFBH-12 价格&库存

很抱歉,暂时无法提供与“RF-SFBH-12”相匹配的价格&库存,您可以联系我们找货

免费人工找货