MicrowaveDevices.book Page 84 Wednesday, November 26, 2008 7:50 PM
RP
1.8 GHZ
HIGH FREQUENCY,
4 mm LOW PROFILE
RELAY
RP RELAYS
FEATURES
Compliance with RoHS Directive
1. High frequency relay with the low
profile of 4 mm .157 inch
2. Excellent high frequency
characteristics
• Isolation: Min. 10dB (at 1.8 GHz)
• Insertion loss: Max. 1.0dB (at 1.8 GHz)
• V.S.W.R.: Max. 1.3 (at 1.8 GHz)
3. High sensitivity in small size
Size: 10.6 × 9 × 4 mm
.417 × .354 × .157 inch
Nominal operating power: 140 mW
4. Utilizes tube package for automatic
mounting.
5. Self-clinching terminal also
available
TYPICAL APPLICATIONS
• Switching signal of measuring
equipment
• All types of compact wireless devices
If you wish to use in applications with low
level loads or with high frequency
switching, please consult us.
ORDERING INFORMATION
RP 1
Contact arrangement
1: 1 Form C
Operating function
Nil: Single side stable
Terminal shape
Nil: Standard PC board terminal
H: Self-clinching terminal
Coil voltage, V DC
1.5, 3, 4.5, 5, 6, 9, 12, 24 V
TYPES
Contact
arrangement
Nominal coil voltage
1 Form C
1.5V DC
3 V DC
4.5V DC
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
Single side stable
Part No.
RP1-1.5V
RP1-3V
RP1-4.5V
RP1-5V
RP1-6V
RP1-9V
RP1-12V
RP1-24V
Standard PC board terminal
Self-clinching terminal Single side stable
Part No.
RP1-H-1.5V
RP1-H-3V
RP1-H-4.5V
RP1-H-5V
RP1-H-6V
RP1-H-9V
RP1-H-12V
RP1-H-24V
Standard packing: 50 pcs. in an inner package (tube); 1,000 pcs. in an outer package
RATING
1. Coil data
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
10%V or more of
nominal voltage*
(Initial)
93.8mA
46.7mA
31.0mA
28.1mA
23.3mA
15.5mA
11.7mA
11.3mA
16 Ω
64.3Ω
145 Ω
178 Ω
257 Ω
579 Ω
1,028 Ω
2,133 Ω
1.5V DC
3 V DC
4.5V DC
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
75%V or less of
nominal voltage*
(Initial)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
140mW
150%V of nominal voltage
270mW
120%V of nominal voltage
*Pulse drive (JIS C5442)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
MicrowaveDevices.book Page 85 Wednesday, November 26, 2008 7:50 PM
RP
2. Specifications
Characteristics
Contact
Item
Arrangement
Initial contact resistance, max.
Contact material
Specifications
1 Form C
Max.50mΩ (By voltage drop 6V DC 0.1A)
Stationary: Ag + Au clad, Movable: AgPd
0.1A 30V DC (resistive load); Contact carrying power: 3W (Max. 1.2GHz);
1W (Max. 1.8GHz); Contact switching power: 1W (Max. 1.8GHz)
140mW (1.5 to 12V DC), 270mW (24V DC)
Max. 1.2 (at 1GHz), Max. 1.3 (at 1.8GHz)
Max. 0.5dB (at 1GHz), Max. 1dB (at 1.8GHz)
Min. 15dB (at 1GHz), Min. 10dB (at 1.8GHz)
Contact rating
Rating
Nominal operating power (single side stable type)
V.S.W.R.
High frequency
characteristics (Initial) Insertion loss (without D.U.T. board’s loss)
(Impedance 50Ω)
Isolation
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Insulation resistance (Initial)
Between open contacts
Breakdown
voltage (Initial) Between contact and coil
Electrical
characteristics
750 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
Max. 50°C (By resistive method, nominal voltage applied to the coil, contact carrying
power: 1W/at 1.8GHz)
Max. 3ms (Approx. 1.5ms) (Nominal operating voltage applied to the coil, excluding
contact bounce time.)
Max. 2ms (Approx. 1ms) (Nominal operating voltage applied to the coil, excluding contact
bounce time.) (without diode)
Min. 500 m/s2 {Approx. 50G} (Half-wave pulse of sine wave: 11ms; detection time: 10µs.)
Min. 1,000 m/s2 {Approx. 100G} (Half-wave pulse of sine wave: 6ms.)
Temperature rise (at 20°C)
Operate time (at 20°C)
Release time (at 20°C)
Mechanical
characteristics
Expected life
Conditions
Shock
resistance
Functional
Destructive
Vibration
resistance
Functional
Destructive
10 to 55 Hz at double amplitude of 3mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 5mm
Min. 5×106 (at 180 cpm)
Min. 105 (0.1A 30V DC resistive load, 1W (at 1.8GHz, V.S.W.R. max. 1.3 at 20 cpm)
Ambient temperature: –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm (at rated load)
Approx. 1 g .04 oz
Mechanical
Electrical
Conditions for operation, transport and storage*
Max. operating speed (at rated load)
Unit weight
Note: * The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to [6] AMBIENT ENVIRONMENT
in GENERAL APPLICATION GUIDELINES.
REFERENCE DATA
1. High frequency characteristics
Sample: RP1-6V
Measuring method: Impedance 50Ω
Measuring tool:
6–1.60 dia
.063 dia
mm inch
6–1.00 dia
.039 dia
26–0.80 dia
.031 dia
0.60
.024
18.92
.745
6–2.30 dia
.090 dia
PC board
• Double-sided through hole
• Material: Glass-epoxy resin
• t = 1.0mm .039 inch
• Copper plated thickness: 35 µm
1.94
.076
18.00 7.62
.709 .300
4.22 9.82
.166 .387
5.08
.200
Soldering
SMA connector
• V.S.W.R
• Insertion loss
3.0
• Isolation
5
100
2.8
90
2.4
2.2
2.0
1.8
1.6
1.4
4
3
2
N.O. (Terminal Nos. 5-6)
N.C. (Terminal Nos. 4-5)
NC (Terminal Nos. 4-5)
NO (Terminal Nos. 5-6)
80
Isolation, dB
Insertion loss, dB
V.S.W.R.
2.6
1
60
50
40
30
20
1.2
1.0
70
10
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Frequency, GHz
0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Frequency, GHz
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Frequency, GHz
MicrowaveDevices.book Page 86 Wednesday, November 26, 2008 7:50 PM
RP
2. Coil temperature rise
3. Operate/release time
Sample: RP1-6V; No. of samples: n = 5
Carrying current: 0.1 A
Ambient temperature: 25°C 77°F
Sample: RP1-9V; No. of samples: n = 50
• With diode
• Without diode
12
100
12
60
50
8
6
8
6
40
4
30
20
4
Max.
Max.
Min.
Min.
2
10
0
80
100
120
0
150
70 80
100
2
120
0
150
4. Mechanical life
5. Electrical life (0.1 A 30 V DC)
Sample: RP1-5V; No. of samples: n = 8
Sample: RP1-6V; No. of samples: n = 6
• Change of pick-up, drop-out voltage
• Change of pick-up/drop-out voltage
8
6
Pick-up voltage
Max.
Min.
Max.
Min.
2
50
120
Contact resistance, mΩ
10
100
120
150
Coil applied voltage, %V
• Change of contact resistance
12
Pick-up/drop-out voltage, V
12
4
Max.
Min.
Max.
Min.
70 80
Coil applied voltage, %V
Coil applied voltage, %V
Pick-up/drop-out voltage, V
10
Time, ms
70
Time, ms
Temperature rise, °C
10
80
Operate time
Release time
Operate time
Release time
90
10
8
6
Pick-up voltage
4
Max.
2
Min.
Max.
Min.
100
80
60
40
Max.
Min.
20
Drop-out voltage
Drop-out voltage
100
500 1,000
0
No. of operations, ×10
4
10
20
No. of operations, ×104
6. Ambient temperature characteristics
7. Contact resistance distribution (initial)
Sample: RP1-6V; No. of samples: n = 5
Sample: RP1-12V; No. of samples: n = 25
30
0
10
20
No. of operations, ×104
30
–40 –20
0
40
40
Drop-out
voltage
20
Pick-up
voltage
20 40 60 80
Ambient
–20 temperature, °C
Quantity
Rate of change, %
50
30
20
10
–40
0
22 24 26 28 30 32 34 36 38 40
Contact resistance, mΩ
Sample: RP1-12V; No. of samples: n = 6
OFF
5
Pick-up voltage
0
OFF
–5
5
OFF
OFF
Pick-up voltage
0
–5
Rate of change, %
8.-(3) Influence of adjacent mounting
Sample: RP1-12V; No. of samples: n = 6
Rate of change, %
8.-(2) Influence of adjacent mounting
Sample: RP1-12V; No. of samples: n = 6
Rate of change, %
8.-(1) Influence of adjacent mounting
OFF
5
Pick-up voltage
0
–5
Drop-out voltage
0
ON
–5
5
ON
ON
Drop-out voltage
0
ON
–5
Rate of change, %
ON
5
OFF
Rate of change, %
Rate of change, %
OFF
5
Drop-out voltage
0
–5
ON
0
5
10
.197
.394
Inter-relay distance, (mm, inch)
ON
0
5
10
.197
.394
Inter-relay distance, (mm, inch)
0
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
5
10
.197
.394
Inter-relay distance, (mm, inch)
MicrowaveDevices.book Page 87 Wednesday, November 26, 2008 7:50 PM
RP
9. High frequency switching test (1.2 GHz, 1 W)
Sample: RP1-6V; No. of samples: n = 6
Ambient temperature: 20°C 68°F
RP relay
Transmission
T1
Dummy load (50Ω)
WD-2351
Transmission: RF Tranceiver
IC-1201 (ICOH)
T2
T1
ON
OFF
12
120
10
100
8
6
Pick-up voltage
Max.
Min.
4
Drop-out voltage
2
T2
0.2s
1.5s
• Change of contact resistance
Contact resistance, mΩ
Pick-up/drop-out voltage, V
• Change of pick-up/drop-out voltage
0
5
60
40
Max.
Min.
20
Max.
Min.
0.2s
1.5s
80
10
15
0
5
10
No. of operations, ×104
No. of operations, ×104
DIMENSIONS (mm inch)
CAD Data
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://panasonic-electric-works.net/ac
Standard PC board terminal
3.75
.148
PC board pattern (Bottom view)
5.08
.200
9
.354
10.6
.417
2.54
.100
4
.157
3.5
.138
7.62
.300
(0.25)
(.010)
2.54
.100
0.5
.020
2.54
.100
0.25
.010
7.62
.300
6-1 dia.
6-.039 dia.
Tolerance: ±0.1 ±.004
Schematic (Bottom view)
Self-clinching terminal
3.75
.148
9
.354
10.6
.417
+
4
.157
3.5
.138
(0.25)
(.010)
2.54
.100
0.5
.020
2.54
.100
15
0.25
.010
7.62
.300
General tolerance: ±0.3 ±.012
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
1 2 3
−
6 5 4
Direction indication
Deenergized condition
MicrowaveDevices.book Page 88 Wednesday, November 26, 2008 7:50 PM
RP
NOTES
Stopper (gray)
Stopper (green)
Orientation (indicates PIN No.1) stripe
5. Automatic mounting
To maintain the internal function of the
relay, the chucking pressure should
not exceed the values below.
Chucking pressure* in the direction A:
4.9 N {500 gf} or less
Chucking pressure* in the direction B:
9.8 N {1 kgf} or less
Chucking pressure* in the direction C:
9.8 N {1 kgf} or less
Please chuck the
portion.
Avoid chucking the center of the relay. In
addition, excessive chucking pressure to
the pinpoint of the relay should be
avoided.
For general cautions for use, please
refer to the “General Application
Guidelines”.
;
;
1. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be
rectangular. If it includes ripple, the ripple
factor should be less than 5%.
However, check it with the actual circuit
since the characteristics may be slightly
different. The nominal operating voltage
should be applied to the coil for more
than 20 ms to set/reset the latching type
relay.
2. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or
malfunction.
3. External magnetic field
Since RP relays are highly sensitive
polarized relays, their characteristics will
be affected by a strong external magnetic
field. Avoid using the relay under that
condition.
4. Packing direction
Relays are packed in a tube with the
orientation stripe (PIN NO. 1) toward the
green stopper.
A
(4)
(5)
(6)
C
mm inch
B
• Direction A • Direction B • Direction C
6 5 4
3
.118
6
.236
3
2
1 2 3
1
*Value of chucking pressure is shown by the value of weight
pressed on the portion (4 mm .157 inch dia.).
6. Soldering
Preheat according to the following
conditions.
Temperature
Time
120°C 248°F or less
Within 2 minute
Soldering should be done at 260±5°C
500±9°F within 6 s.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.