RT3SN-24V

RT3SN-24V

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
RT3SN-24V 数据手册
Slim, Space-saving, 4-point Unit Relay RT-3 UNIT RELAY 4-POINT TERMINAL [PA-N Relay type, PhotoMOS Power (Voltage sensitive type)] FEATURES 1. Slim, space-saving type (33 mm 1.299 inch wide) with four independent points on a base measuring 33 × 67 mm 1.299 × 2.638 inch. This contributes to a more compact control panel. 2. Can be mounted on a DIN rail or mounted directly (by screw). 3. Equipped with an LED display to allow easy confirmation of operation. 4. Possible to select a relay for use in the 4-point terminal in accordance with its application. 4-point Terminal [PA-N relay, PhotoMOS Power (Voltage sensitive type)] Mountable relay RT-3 Unit relay PA-N relay PhotoMOS Power (Voltage sensitive type) RoHS compliant TYPES 1. RT-3 Unit relay Contact arrangement 1 Form A × 4 Rated input voltage 12 V DC 24 V DC Part No. RT3SN-12V RT3SN-24V Rated input voltage Part No. 12, 24V DC RT3BB Standard packing: Carton: 1 pc.; Case: 20 pcs. Note: PA-N relays are installed. 2. 4-point Terminal Type PA-N relay, PhotoMOS Power type (Voltage sensitive type) Standard packing: Carton: 1 pc.; Case: 20 pcs. 3. Mountable relays for 4-point Terminal (per relay, at 25°C 77°F, initial) Product Name PA-N relay Part No. APAN3112, APAN3124 AQZ10∗D (DC only) AQZ20∗D (AC/DC dual use) PhotoMOS Power type (Voltage sensitive type) Notes: 1. Never install relays into this product other than those given above. Doing so will cause malfunction, breakdown, and breakdown of the connected product. 2. Cannot be equipped with PhotoMOS Power standard type relays. However, equipping with voltage-sensitive type of PhotoMOS Power type is possible. RATING 1. RT-3 Unit relay 1) Input ratings (per PA-N relay) Part No. Rated input voltage RT3SN-12V RT3SN-24V 12 V DC 24 V DC Input current (at rated input voltage, 20°C 68°F) Approx. 10.7 mA (Relay 9.2 mA + LED 1.5 mA) Approx. 7.6 mA (Relay 4.6 mA + LED 3.0 mA) –1– Allowable variation of rated input voltage (–20 to +55°C –4 to +131°F) 12 V DC ± 10% 24 V DC ± 10% ASCTB369E 201701-T RT-3 Unit Relay/4-point Terminal (PA-N Relay type) 2) PA-N relay coil specifications (Reference value) Relay part No. Pick-up voltage (Initial) (at 20°C 68°F) Drop-out voltage (Initial) (at 20°C 68°F) Coil resistance (±10%) (at 20°C 68°F) Rated operating power 70%V or less of Rated voltage (initial) 5%V or more of Rated voltage (initial) 1,309 Ω 110 mW 5,236 Ω 110 mW APAN3112 APAN3124 3) Output ratings (per PA-N relay) Specification Item Contact rating (Resistive load) Max. switching power (Resistive load) Max. switching voltage Max. switching current Min. switching load (Reference value) Mechanical life Contact data Expected life Specifications 3 A 250 V AC, 3 A 30 V DC 750 VA (AC), 90 W (DC) 250 V AC, 30 V DC 3A 1 mA, 5 V DC Min. 2 × 107 (at 180 times/min.) Min. 3 × 104: 3 A 250V AC Min. 3 × 104: 3 A 30V DC Min. 105: 2 A 250V AC Min. 105: 2 A 30V DC Electrical life (Resistive load) Note: During 4-point simultaneous operation, the rating per point is also as shown above. 2. 4-point Terminal 1) Input ratings (per relay) Rated input voltage 12, 24V DC Allowable variation of rated input voltage 12V DC±10%, 24V DC±10% Allowable input current 0.2A Note: The input voltage value above is the allowable current when no relay is installed. Please note that input voltage is determined by the type of relay installed. 2) Input rating when PA-N relay installed (per relay, at 20°C 68°F) Type Rated input voltage APAN3112 12V DC APAN3124 24V DC Operate voltage (Initial) Release voltage (Initial) Max. 9.5V DC (Relay max. 8.4V + include diode max. 1.1V) Max. 17.9V DC (Relay max. 16.8V + include diode max. 1.1V) Min. 1.0V DC (Relay min. 0.6V + include diode min. 0.4V) Min. 1.6V DC (Relay min. 1.2V + include diode min. 0.4V) Input current (during application of rated voltage) Approx. 10.7mA (Relay 9.2mA + LED 1.5mA) Approx. 7.6mA (Relay 4.6mA + LED 3.0mA) 3) Input rating when PhotoMOS Power voltage sensitive type installed (per relay, at 25°C 77°F) Type Rated input voltage Operate voltage (Initial) Release voltage (Initial) AQZ∗0∗D 12, 24V DC Max. 5.1V DC (Relay max. 4.0V + include diode max. 1.1V) Min. 1.2V DC (Relay min. 0.8V + include diode min. 0.4V) Input current (during application of rated input voltage) Approx. 10.0mA (Relay 7.0mA + LED 3.0mA) 4) Output rating (per relay) Allowable load voltage 600V (DC), 600V (AC peak value) Allowable load current 3A Note: The value above is the allowable value when no relay is installed. Please note that limitations apply to the load voltage and current depending on the type of relay installed. 5) Output rating when PA-N relay installed (per relay, at 20°C 68°F) Specification Item Contact rating (Resistive load) Max. switching power (Resistive load) Max. switching voltage Max. switching current Min. switching load (Reference value) Mechanical life Contact data Expected life Specifications 3 A 250 V AC, 3 A 30 V DC 750 VA (AC), 90 W (DC) 250 V AC, 30 V DC 3A 1 mA, 5 V DC Min. 2×107 (at 180 times/min.) Min. 3×104: 3 A 250V AC, 3 A 30V DC Min. 105: 2 A 250V AC, 2 A 30V DC Electrical life (Resistive load) Note: During 4-point simultaneous operation, the rating per point is also as shown above. 6) Output rating when PhotoMOS Power voltage sensitive type installed (per relay, at 25°C 77°F) Possible relays Type DC only Part No. AQZ102D AQZ105D AQZ107D AQZ104D Maximum load voltage (DC, AC peak value) Continuous load current (DC, AC peak value) 60V 1.80A 100V 200V 400V 1.15A 0.55A 0.30A Possible relays Type Part No. Maximum load voltage (DC, AC peak value) Continuous load current (DC, AC peak value) AC, DC dual use AQZ202D AQZ205D AQZ207D AQZ204D 60V 100V 200V 400V 1.350A 0.900A 0.450A 0.225A Notes: 1. During 4-point simultaneous operation, the rating per point is also as shown above. 2. Please use a load current that is within the range of the data given below in “REFERENCE DATA Load current vs. ambient temperature characteristics”. –2– ASCTB369E 201701-T RT-3 Unit Relay/4-point Terminal (PA-N Relay type) SPECIFICATIONS RT-3 Unit relay/4-point Terminal Item Dielectric strength (Initial) Specifications Between input and output Between different terminals (between relays, both ways) Insulation resistance (Initial) Vibration resistance Destructive Functional Condition 2,000 Vrms for 1 min. 1,500 Vrms for 1 min. Min. 100 MΩ (Measurement at same location as “Breakdown voltage” section.) Using 500 V DC megger 10 to 55 Hz at double amplitude 1 mm .039 inch 10 to 55 Hz at double amplitude 1 mm .039 inch Destructive Functional Ambient temperature Condition Ambient humidity Storage temperature Terminal screw fasten torque Coil surge absorber Cross connection protecting diode Unit weight Min. 196 m/s2 Min. 98 m/s2 –20 to +55°C –4 to +131°F 35 to 85% R.H. –30 to +80°C –22 to +176°F 0.3 to 0.5 N·m Diode (1A, 400V) 1 A, inverse voltage 400 V Approx. 100 g 3.53 oz Shock resistance In vertical, horizontal and longitudinal directions In vertical, horizontal and longitudinal directions In vertical, horizontal and longitudinal directions In vertical, horizontal and longitudinal directions Not freezing and condensing Not condensing Not freezing and condensing Notes: 1. The value of breakdown voltage and insulation resistance is the initial one. 2. Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere. This may cause some troubles like insulation failure of the socket or the print circuit board. Take care under this condition. 3. Below 0°C 32°F, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition. REFERENCE DATA 1. Maximum value for switching capacity (output) 2. Load current vs. ambient temperature characteristics (DC only) 3. Load current vs. ambient temperature characteristics (AC/DC dual use) Per PA-N relay 10 2 DC resistive load 1 Load current, A Load current, A Contact current, A 2 AQZ102D AC resistive load AQZ105D 1 AQZ202D 1 AQZ205D AQZ107D AQZ207D AQZ104D 0.1 1 10 100 Contact voltage, V 1000 –20 –10 0 –4 14 32 10 50 AQZ204D 20 68 30 40 50 60 86 104 122 140 Ambient temperature, °C °F –3– –20 –10 0 –4 14 32 10 50 20 68 30 40 50 60 86 104 122 140 Ambient temperature, °C °F ASCTB369E 201701-T RT-3 Unit Relay/4-point Terminal (PA-N Relay type) DIMENSIONS (mm inch) 1. External dimensions 7.62 .300 2. Schematic Input terminal socket portion 33±0.6 1.299±.024 6.2 .244 16-M3 .118 terminal screw Input side 8.4 .331 13+ 14+ 15+ 16+ 9– 10– 11– 12– LED1 LED2 LED3 LED4 5+ 6+ 7+ 8+ 1– 2– 3– 4– R2.1 .083 2-M4 .157 screw mounting position 67±1 2.638±.039 7.4 .291 4.2+0.3 −0.1 .165+.012 −.004 R3.7 .146 Output side Output terminal socket portion With cover removed 4 .157 5.5±0.6 .217±.024 13.8 .543 32±1 1.260±.039 Note: It is PA-N relay type. Cannot be equipped with PhotoMOS Power standard type relays. However, equipping with voltage sensitive type of PhotoMOS Power type is possible. The polarities of the output terminal socket are for the DC only type (equipped with AQZ10∗D) ±0.6 30 1.181±.024 3. Mounting hole pattern 2-4.3 dia. or M4 2-.169 dia. or M.157 General tolerance: ±0.3 ±.012 30±0.1 1.181±.004 –4– ASCTB369E 201701-T CAUTIONS FOR USE 1. Never install modules (relays) into this product other than those designated. Doing so will cause malfunction, breakdown, and breakdown of the connected product. 2. If a unit is dropped be sure to check its external appearance and characteristics before using it. 3. The operation and return voltage values when equipped with PA-N relays are based on the relay terminals being face down. (RT-3 Unit relay (PAN type), 4-point Terminal) 4. Switching lifetime (PA-N relay) This characteristic depends on the relay and is effected by coil driving circuit, load type, activation frequency, activation phase, ambient conditions and other factors. Also, be especially careful of loads such as those listed below. 1) When used for AC load-operating and the operating phase is synchronous, rocking and fusing can easily occur due to contact shifting. 2) Frequent switching under load condition When high frequently switched under load condition that can cause arc at the contacts, nitrogen and oxygen in the air is fused by the arc energy and HNO3 is formed. This can corrode metal materials. Three countermeasures for these are listed here. (1) Incorporate an arc-extinguishing circuit. (2) Lower the operating frequency (3) Lower the ambient humidity 5. Operating environment 1) Keep the product as far way as possible from power cables, high tension equipment, power equipment, equipment with transmitting devices such as amateur radios, or equipment which generates a large switching surge. 2) The main unit is made of resin; therefore, do not use it in areas where it may come in contact with (or be exposed to) organic solvents such as gasoline, thinner, and alcohol, or strong alkaline substances such as ammonia and caustic soda. 3) Do not use the product in areas where it may be exposed to flammable gases, corrosive gases, excessive dust, or moisture, or areas where it may be subjected to strong vibration or shock. 6. Installing and removing the module 1) Firmly insert the module into the socket with the terminals going in the direction of the blade receptacles. 2) The module can be easily removed using the removal key. (1) Insert the removal key into the socket slots. RT-3 UNIT RELAY 4-POINT TERMINAL when equipped with AQZ10∗D (DC type). Also, with the RT-3 Unit relay (PhotoMOS Power type), be careful of the polarity on the output side of the DC type (RT3SP1∗∗V for type equipped with AQZ102). 2) We recommend the use of wirepressed terminals for connection to the terminal portion. • Example of applicable wire-pressed terminal Company Name Part Name Applicable wirepressed terminal J.S.T. Mfg Co., Ltd. 1.25 to C3A 0.25 to 1.65mm2 3) When the load is inductive, limit spike voltages generated from the load to less than the maximum load voltage. Typical circuits are shown below. (1) Add a clamp diode to the load. Output terminals (2) Pull the removal key up to remove the module. Load (2) Add an R-C snubber to the load. Output terminals Load or DC only for AQZ10∗D equipped type (3) Slide the removal key off of the module. (3) Add a varistor between the output terminals. Output terminals Load or DC only for AQZ10∗D equipped type 7. Wiring and circuit configuration 1) Perform wiring according to the internal schematic. Take care not to make any mistakes. In particular, with the RT-3 Unit relay (PAN relay type) and 4-point terminal, be careful of the polarity on the output side –1– 4) Even if spike voltages generated from the load are limited by a clamp diode or R-C snubber, inductances in long circuit wires will still create spike voltages. Keep wires as short as possible to minimize inductance. ASCTB371E 201701-T CAUTIONS FOR USE 8. Installation 1) Perform mounting hole cutout according to the panel cutout drawings. 2) When installing the unit on a DIN rail, use the DIN rail locking lever on the side of the unit. Installation is accomplished by simply fitting the unit onto the rail and pressing gently. 1 First push in the DIN rail locking lever. DIN rail locking lever DIN rail 3 Press the unit onto the DIN rail. 2 Hook the holders on the unit over the DIN rail. 3) To remove the unit from the DIN rail, use a flat head screwdriver to pull out the DIN rail locking lever. 9. Transporting and storage 1) If the product is subjected to extreme vibration while being transported, the relays may become detached, the lead may become bent, and the unit may become damaged. Handle the carton and case with care. 2) If the product is stored in an extremely adverse environment, visible defects and deterioration of performance characteristics may result. We recommend the following storage conditions. • Temperature: 5 to 30°C 41 to 86°F • Humidity: Max. 60% R.H. • Environment: No hazardous substances such as sulfurous acid gases and little dust. 10. When equipped with PhotoMOS Power voltage drive type [RT-3 Unit relay (PA-N relay type), 4-point Terminal] Since the PhotoMOS Power voltage sensitive type does not require the current-controlling resistance on the input side, it can be used together with PA-N relays on RT-3 unit relay (PA-N relay type). When connecting PhotoMOS Power voltage sensitive types, since it will be a close connection, it will be necessary to be careful of load currents. Be sure to refer to the information given regarding “Load currents vs ambient temperature characteristics” in the precautions given for use of 4-point terminals. 3 Remove the unit from the DIN rail. 2 Move the screwdriver in the direction of the arrows, and pull out the lever. 1 Insert the tip of the flat head screwdriver into the slot in the DIN rail locking lever. TERMINAL BLOCK We recommend using wire-pressed terminals for connection to the terminal portion. • Applicable electrical wire: 0.25 to 1.65 mm2 .01 to .065 inch • Applicable wire-pressed terminals (mm inch) 3 dia. min. .118 dia. min. 5.8 max. .228 max. 3 min. .118 min. 5.8 max. .228 max. 4 4.5 min. .157 .177 min. Company Name J.S.T. Mfg Co., Ltd. NICHIFU Nippon Tanshi Co., Ltd. 4 4.5 min. .157 .117 min. Part Name 1.25 to C3A 1.25Y to 3N VD1.25 to 3L Part Name 1.25 to 3 1.25 to 3 R1.25 to 3 ACCESSORIES Short circuit plate for RT-3 Unit relay Use when you want to bridge terminals. < With insulator > < Without insulator > AY3802 External dimensions (mm inch) 28.7 1.130 7.62±0.3 .300±.012 5.8±0.1 .228±.004 3.1±0.1 .122±.004 0.5 .020 AY3803 External dimensions (mm inch) 28.7 1.130 7.62±0.3 .300±.012 5.8±0.1 .228±.004 3.1±0.1 .122±.004 R 0.5 .020 R 17.8 .701 13.8 .543 +0 8−3 .315+0 −.118 28+0.5 −1 1.102+.020 −.039 General tolerance: ±0.5 ±.020 –2– 1.5 to 2.5 .059 to .098 17 .669 13 .512 26.5 1.043 General tolerance: ±0.5 ±.020 ASCTB371E 201701-T
RT3SN-24V 价格&库存

很抱歉,暂时无法提供与“RT3SN-24V”相匹配的价格&库存,您可以联系我们找货

免费人工找货