Interface Terminal
RT-3 UNIT RELAY
( PhotoMOS Power type)
/4-POINT TERMINAL
( Without relay type )
Product Catalog
" ", " PhotoMOS " and " PHOTOMOS " are registered trademarks of Panasonic Holdings Corporation.
Recognized in Japan, the United States, all member states of European Union and the other countries.
2024.2
Interface Terminal
RT-3 UNIT RELAY ( PhotoMOS Power type ) /4-POINT TERMINAL ( Without relay type )
Slim, Space-saving, RT-3 Unit relay ( Equipped with long-life PhotoMOS power type )
FEATURES
● Slim shape with width of 33 mm
● PhotoMOS Power type, for high reliability
and long life, are installed.
● Can be mounted on a DIN rail or mounted
directly by screw.
4-point Terminal
(Without relay type)
● Equipped with an LED display to allow easy
confirmation of operation.
Mountable relay
● Possible to select a relay for use in the
4-point terminal in accordance with its load.
RT-3 Unit relay
(PhotoMOS Power type)
PhotoMOS Power type
TYPES
" Type No. " is ordering part number for non Japanese market. " Part No. " is ordering part number for Japanese market.
■ RT-3 Unit relay ( PhotoMOS Power type )
Contact
arrangement
1 Form A × 4
Rated input
voltage
Type No.
Part No.
DC only
( Equipped with AQZ102 )
12 V DC
RT3SP1-12V
AY34001
24 V DC
RT3SP1-24V
AY34002
AC/DC dual use
( Equipped with AQZ204 )
12 V DC
RT3SP2-12V
AY35001
24 V DC
RT3SP2-24V
AY35002
Type
Standard packing
Inner carton
Outer carton
1 pc.
20 pcs.
Notes) 1: 4 pieces PhotoMOS Power types are installed. Cannot be equipped with PA-N relays.
2: For other contact arrangement, please contact our sales representative.
■ 4-point Terminal (Without relay type)
Type
Without relay type
Rated input
voltage
Type No.
Part No.
12 V DC
RT3BB-12V
AY30001
24 V DC
RT3BB-24V
AY30002
Standard packing
Inner carton
Outer carton
1 pc.
20 pcs.
Note) Relay sold separately. Please refer to the following for the relays that can be mounted.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー1ー
Panasonic Industry Co., Ltd. 2024
ASCTB9E 202402
RT-3 UNIT RELAY ( PhotoMOS Power type ) /4-POINT TERMINAL ( Without relay type )
■ Mountable relays for 4-point Terminal
( per relay, at 25℃, initial )
Mountable relays
Output
Max. load voltage
Continuous
load current
Part No.
AQZ102
60 V DC
0 to 30 V DC
2.00 A
9.0 A
PhotoMOS
Power type
( DC only )
AQZ105
100 V DC
0 to 50 V DC
1.50 A
6.0 A
AQZ107
200 V DC
0 to 100 V DC
0.70 A
3.0 A
AQZ104
400 V DC
0 to 200 V DC
0.40 A
1.5 A
0 to 12 V AC/0 to 30 V DC
1.80 A
9.0 A
60 V ( peak )
AQZ202
PhotoMOS
Power type
( AC/DC dual use )
Notes) 1:
2:
3:
4:
5:
Recommended load voltage
Peak load
current
Type
AQZ205
100 V ( peak )
0 to 24 V AC/0 to 50 V DC
1.20 A
6.0 A
AQZ207
200 V ( peak )
0 to 48 V AC/0 to 100 V DC
0.60 A
3.0 A
AQZ204
400 V ( peak )
0 to 125 V AC/0 to 200 V DC
0.30 A
1.5 A
AQZ404
( 1 Form B type )
400 V ( peak )
0 to 125 V AC/0 to 200 V DC
0.30 A
1.5 A
Peak load current is limited to " 100 ms, 1 shot " .
During 4-point simultaneous operation, the rating per point is also as shown in the table above.
Please use a load current that is within the range of the data given below in " REFERENCE DATA Load current vs. ambient temperature characteristics " .
Be very careful regarding the polarity on the output side when equipped with AQZ10* ( dedicated PhotoMOS Power type ( DC only ) ) .
Never install relays into this product other than those given above. Doing so will cause malfunction, breakdown, and breakdown of the connected product.
RATING
■ Input rating ( per relay )
Part No.
Rated input voltage
Operate voltage
( at 25 ℃ )
Release voltage
( at 25 ℃ )
Input current
during application of
rated input voltage
( at 25 ℃ )
12 V DC
Max. 9.5 V DC
( 5.1 V typ. )
Min. 3.0 V DC
( 5.0 V typ. )
6.2 mA typ.
24 V DC
Max. 15.0 V DC
( 6.8 V typ. )
Min. 3.5 V DC
( 6.5 V typ. )
6.7 mA typ.
AY34001
AY35001
AY34002
AY35002
Allowable variation of
rated input voltage
( at −20 to +55 ℃ )
90 to 110 % V of
rated input voltage
Note) This product has a built-in input current limiting resistor; therefore, it is not necessary to externally connect a resistor to the input. The input voltage can be applied
directly.
■ Output rating ( per relay, at 25 ℃ )
Part No.
Equipped relay
Max. load voltage
Recommended
voltage
Continuous load
current
Peak load currant
AY34001
AQZ102
( DC only )
60 V
( DC )
0 to 30 V ( DC )
2 A
( DC )
9 A
( 100 ms 1 shot )
AQZ204
( AC/DC dual use )
400 V
( DC, AC peak value )
0 to 200 V ( DC )
0 to 125 V ( AC )
0.3 A
( DC, AC peak value )
1.5 A
( 100 ms 1 shot )
AY34002
AY35001
AY35002
Notes) 1: During 4-point simultaneous operation, the rating per point is also as shown in the table above.
2: The load current varies depending on ambient temperature. Refer to the " REFERENCE DATA Load current vs. ambient temperature characteristics " .
SPECIFICATIONS
Item
Dielectric
strength
( initial )
Use condition
Conditions
2,000 V AC
for 1 min
Between different terminals
( between relays, both ways )
1,500 V AC
for 1 min
Min. 100 MΩ
(Measured portion is the same as the case of
dielectric strength. )
Using 500 V DC megger
Destructive shock resistance
Min. 196 m/s2
In vertical, horizontal and longitudinal
directions
Destructive vibration resistance
10 to 55 Hz at double amplitude of 1 mm
In vertical, horizontal and longitudinal
directions
Ambient temperature
−20 to +55 ℃
Avoid icing and condensation
Ambient humidity
35 to 85 % RH
Avoid condensation
Storage temperature
−30 to +80 ℃
Avoid icing and condensation
Insulation resistance
Shock
resistance
Specifications
Between input and output
Terminal screw fasten torque
0.3 to 0.5 N·m ( 3 to 5 kgf·cm )
Cross connection protecting diode
1 A, inverse voltage 400 V
Unit weight
Approx. 100 g
Notes) 1: Dielectric strength and insulation resistance are initial values.
2: Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere.
This may cause some troubles like insulation failure of the socket or the PC board. Take care under this condition.
3: Below 0 ℃, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー2ー
Panasonic Industry Co., Ltd. 2024
ASCTB9E 202402
RT-3 UNIT RELAY ( PhotoMOS Power type ) /4-POINT TERMINAL ( Without relay type )
REFERENCE DATA
1-1. Load current vs. ambient
1-2. Load current vs. ambient
temperature characteristics
temperature characteristics
Allowable ambient temperature: –20°C to +55°C
Allowable ambient temperature: –20°C to +55°C
2
2
AQZ202
Load current, A
RT3SP1-12 or 24 V
(AQZ102 equipped type)
Load current, A
AQZ102
1
AQZ105
AQZ205
1
AQZ107
RT3SP2-12 or 24 V
(AQZ204 equipped type)
AQZ207
AQZ104
AQZ204, AQZ404
-20
-10
0
10
20
30
40 50
Ambient temperature, °C
60
-20
-10
0
10
20
30
40 50
Ambient temperature, °C
60
DIMENSIONS ( Unit: mm )
CAD
External dimensions
Schematic
7.62
Input terminal socket portion
Input side
8.4
R2.1
2-M4 screw
mounting position
13+
14+
15+
16+
ķ
ķ
ķ
ķ
LED 2
16-M3 terminal screw
LED 1
33 ±0.6
6.2
5
+
1ķ
6
+
2ķ
LED 4
CAD
mark can be downloaded from our Website.
LED 3
CAD The CAD data of the products with a
7
8
+
4
ķ
67 ±1
7.4
4.2 +0.3
ķ
R3.7
Output side
+
3ķ
Output terminal socket portion
4
5.5 ±0.6
Note: The polarities of the output terminal socket are
for the DC only type (equipped with AQZ 10*)
13.8
With cover removed
30 ±0.6
32 ±1
Mounting hole pattern
General tolerance: ± 0.3
2 φ4.3 or M4
30±0.1
GUIDELINES FOR USAGE
■ For cautions for use, please read " GUIDELINES FOR RELAY USAGE " .
https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー3ー
Panasonic Industry Co., Ltd. 2024
ASCTB9E 202402
CAUTIONS FOR USE RT-3 UNIT RELAY 4-POINT TERMINAL
■ Never install modules ( relays ) into this product
other than those designated. Doing so will cause
malfunction, breakdown, and breakdown of the
connected product.
■ Installing and removing the module
1) Firmly insert the module into the socket with
the terminals going in the direction of the blade
receptacles.
■ If a unit is dropped, be sure to check its external
appearance and characteristics before using it.
2) The module can be easily removed using the removal
■ The operate and release voltage values when
equipped with PA-N relays are based on the
relay terminals being face down.
( RT-3 Unit relay ( PA-N type ), 4-point Terminal )
If you lose it, you can purchase APA801 separately as
key ( APA801 ). The removal key ( APA801 ) is included
in 4-point Unit Relay and 4-point Terminal.
accessories.
① Insert the removal key ( APA801 ) into the socket slots.
■ Switching lifetime ( PA-N relay )
This characteristic depends on the relay and
is effected by coil driving circuit, load type,
activation frequency, activation phase, ambient
conditions and other factors.
Also, be especially careful of loads such as those listed
below.
1) When used for AC load-operating and the operating
phase is synchronous, rocking and fusing can easily
occur due to contact shifting.
② Pull the removal key ( APA801 ) up to remove the module.
2) Frequent switching under load condition When high
frequently switched under load condition that can
cause arc at the contacts, nitrogen and oxygen in the
air is fused by the arc energy and HNO3 is formed. This
can corrode metal materials. Three countermeasures
for these are listed here.
( 1 ) Incorporate an arc-extinguishing circuit.
( 2 ) Lower the operating frequency
( 3 ) Lower the ambient humidity
③ Slide the removal key ( APA801 ) off of the module.
■ Operating environment
1) Keep the product as far away as possible from power
cables, high tension equipment, power equipment,
equipment with transmitting devices such as amateur
radios, or equipment which generates a large switching
surge.
2) The main unit is made of resin; therefor, do not use
it in areas where it may come in contact with ( or be
exposed to ) organic solvents such as gasoline, thinner,
and alcohol, or strong alkaline substances such as
ammonia and caustic soda.
3) Do not use the product in areas where it may be
exposed to flammable gases, corrosive gases, excessive
dust, or moisture, or areas where it may be subjected
to strong vibration or shock.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー4ー
Panasonic Industry Co., Ltd. 2024
ASCTB371E 202402
CAUTIONS FOR USE RT-3 UNIT RELAY 4-POINT TERMINAL
■ Installation
■ Wiring and circuit configuration
1) Perform mounting hole cutout according to the panel
1) Perform wiring according to the internal schematic.
cutout drawings.
Take care not to make any mistakes. In particular,
with the RT-3 Unit relay ( PA-N relay type ) and 4-point
terminal, be careful of the polarity on the output side
2) When installing the unit on a DIN rail, use the DIN rail
when equipped with AQZ10*D ( DC type ). Also,
locking lever on the side of the unit. Installation is
with the RT-3 Unit relay ( PhotoMOS Power type ), be
careful of the polarity on the output side of the DC
accomplished by simply fitting the unit onto the rail
and pressing gently.
type ( RT3SP1-**V for type equipped with AQZ102 ).
1. First push in
the DIN rail
locking lever.
2) We recommend the use of wire-pressed terminals for
connection to the terminal portion.
DIN rail locking lever
● Example of applicable wire-pressed terminal
Company Name
Part Name
Applicable wirepressed terminal
J.S.T. Mfg Co., Ltd.
1.25 to C3A
0.25 to 1.65 mm2
DIN rail
3. Press the unit onto
the DIN rail.
2. Hook the holders on the
unit over the DIN rail.
3) To remove the unit from the DIN rail, use a flat head
screwdriver to pull out the DIN rail locking lever.
3) When the load is inductive, limit spike voltages
generated from the load to less than the maximum
load voltage.
Typical circuits are shown below.
① Add a clamp diode to the load.
3. Remove the unit from
the DIN rail.
Output terminals
2. Move the
screwdriver in
the direction of
the arrows, and
pull out the lever.
Load
② Add an R-C snubber to the load.
1. Insert the tip of the flat head screwdriver
into the slot in the DIN rail locking lever.
Output terminals
■ Transporting and storage
Load
1) If the product is subjected to extreme vibration while
being transported, the relays may become detached,
the lead may become bent, and the unit may become
damaged. Handle the carton and case with care.
or
DC only for AQZ 10*D
equipped type
③ Add a varistor between the output terminals.
2) If the product is stored in an extremely adverse
environment, visible defects and deterioration
of performance characteristics may result. We
recommend the following storage conditions.
・Temperature: 5 to 30 ℃
・Humidity: Max. 60 % R.H.
・Environment: No hazardous substances such as
sulfurous acid gases and little dust.
Output terminals
Load
or
DC only for AQZ 10*D
equipped type
4) Even if spike voltages generated from the load are
limited by a clamp diode or R-C snubber, inductances
in long circuit wires will still create spike voltages.
Keep wires as short as possible to minimize inductance.
■ When equipped with PhotoMOS Power voltage
drive type
[ RT-3 Unit relay ( PA-N relay type ), 4-point
Terminal ]
Since the PhotoMOS Power voltage sensitive type does
not require the current-controlling resistance on the input
side, it can be used together with PA-N relays on RT-3 unit
relay ( PA-N relay type ).
When connecting PhotoMOS Power voltage sensitive
types, since it will be a close connection, it will be
necessary to be careful of load currents. Be sure to refer
to the information given regarding "Load currents vs
ambient temperature characteristics" in the precautions
given for use of 4-point terminals.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー5ー
Panasonic Industry Co., Ltd. 2024
ASCTB371E 202402
CAUTIONS FOR USE RT-3 UNIT RELAY 4-POINT TERMINAL
TERMINAL BLOCK
We recommend using wire-pressed terminals for connection to the terminal portion.
● Applicable electrical wire
0.25 to 1.65 mm2
● Applicable wire-pressed terminals ( mm )
Min. 3 dia.
Max.
5.8 Min. 3
4
Max. 5.8
Min. 4.5
4
Company Name
Min. 4.5
Part Name
Part Name
J.S.T. Mfg Co., Ltd.
1.25 to C3A
1.25 to 3
NICHIFU
1.25Y to 3N
1.25 to 3
Nippon Tanshi Co., Ltd.
VD1.25 to 3L
R1.25 to 3
ACCESSORIES
■ Short circuit plate for RT-3 Unit relay
Use when you want to bridge terminals.
〈 With insulator 〉
〈 Without insulator 〉
AY3803
AY3802
External dimensions ( mm )
External dimensions ( mm )
28.7
28.7
7.62 ±0.3
7.62 ±0.3
5.8 ±0.1
5.8 ±0.1
0.5
3.1 ±0.1
0.5
3.1 ±0.1
R
R
17.8
13.8
17
8
13
+0
-3
1.5 to 2.5
26.5
28 +0.5
-1
General tolerance: ± 0.5
General tolerance: ±0.5
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
ー6ー
Panasonic Industry Co., Ltd. 2024
ASCTB371E 202402