RT3SP1-12V

RT3SP1-12V

  • 厂商:

    NAIS(松下)

  • 封装:

    模块

  • 描述:

    RT3SP1 12V

  • 数据手册
  • 价格&库存
RT3SP1-12V 数据手册
Interface Terminal RT-3 UNIT RELAY ( PhotoMOS Power type) /4-POINT TERMINAL ( Without relay type ) Product Catalog "     ", " PhotoMOS " and " PHOTOMOS " are registered trademarks of Panasonic Holdings Corporation. Recognized in Japan, the United States, all member states of European Union and the other countries. 2024.2 Interface Terminal RT-3 UNIT RELAY ( PhotoMOS Power type ) /4-POINT TERMINAL ( Without relay type ) Slim, Space-saving, RT-3 Unit relay ( Equipped with long-life PhotoMOS power type ) FEATURES ● Slim shape with width of 33 mm ● PhotoMOS Power type, for high reliability and long life, are installed. ● Can be mounted on a DIN rail or mounted directly by screw. 4-point Terminal (Without relay type) ● Equipped with an LED display to allow easy confirmation of operation. Mountable relay ● Possible to select a relay for use in the 4-point terminal in accordance with its load. RT-3 Unit relay (PhotoMOS Power type) PhotoMOS Power type TYPES " Type No. " is ordering part number for non Japanese market. " Part No. " is ordering part number for Japanese market. ■ RT-3 Unit relay ( PhotoMOS Power type ) Contact arrangement 1 Form A × 4 Rated input voltage Type No. Part No. DC only ( Equipped with AQZ102 ) 12 V DC RT3SP1-12V AY34001 24 V DC RT3SP1-24V AY34002 AC/DC dual use ( Equipped with AQZ204 ) 12 V DC RT3SP2-12V AY35001 24 V DC RT3SP2-24V AY35002 Type Standard packing Inner carton Outer carton 1 pc. 20 pcs. Notes) 1: 4 pieces PhotoMOS Power types are installed. Cannot be equipped with PA-N relays. 2: For other contact arrangement, please contact our sales representative. ■ 4-point Terminal (Without relay type) Type Without relay type Rated input voltage Type No. Part No. 12 V DC RT3BB-12V AY30001 24 V DC RT3BB-24V AY30002 Standard packing Inner carton Outer carton 1 pc. 20 pcs. Note) Relay sold separately. Please refer to the following for the relays that can be mounted. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー1ー Panasonic Industry Co., Ltd. 2024 ASCTB9E 202402 RT-3 UNIT RELAY ( PhotoMOS Power type ) /4-POINT TERMINAL ( Without relay type ) ■ Mountable relays for 4-point Terminal ( per relay, at 25℃, initial ) Mountable relays Output Max. load voltage Continuous load current Part No. AQZ102 60 V DC 0 to 30 V DC 2.00 A 9.0 A PhotoMOS Power type ( DC only ) AQZ105 100 V DC 0 to 50 V DC 1.50 A 6.0 A AQZ107 200 V DC 0 to 100 V DC 0.70 A 3.0 A AQZ104 400 V DC 0 to 200 V DC 0.40 A 1.5 A 0 to 12 V AC/0 to 30 V DC 1.80 A 9.0 A 60 V ( peak ) AQZ202 PhotoMOS Power type ( AC/DC dual use ) Notes) 1: 2: 3: 4: 5: Recommended load voltage Peak load current Type AQZ205 100 V ( peak ) 0 to 24 V AC/0 to 50 V DC 1.20 A 6.0 A AQZ207 200 V ( peak ) 0 to 48 V AC/0 to 100 V DC 0.60 A 3.0 A AQZ204 400 V ( peak ) 0 to 125 V AC/0 to 200 V DC 0.30 A 1.5 A AQZ404 ( 1 Form B type ) 400 V ( peak ) 0 to 125 V AC/0 to 200 V DC 0.30 A 1.5 A Peak load current is limited to " 100 ms, 1 shot " . During 4-point simultaneous operation, the rating per point is also as shown in the table above. Please use a load current that is within the range of the data given below in " REFERENCE DATA Load current vs. ambient temperature characteristics " . Be very careful regarding the polarity on the output side when equipped with AQZ10* ( dedicated PhotoMOS Power type ( DC only ) ) . Never install relays into this product other than those given above. Doing so will cause malfunction, breakdown, and breakdown of the connected product. RATING ■ Input rating ( per relay ) Part No. Rated input voltage Operate voltage ( at 25 ℃ ) Release voltage ( at 25 ℃ ) Input current during application of rated input voltage ( at 25 ℃ ) 12 V DC Max. 9.5 V DC ( 5.1 V typ. ) Min. 3.0 V DC ( 5.0 V typ. ) 6.2 mA typ. 24 V DC Max. 15.0 V DC ( 6.8 V typ. ) Min. 3.5 V DC ( 6.5 V typ. ) 6.7 mA typ. AY34001 AY35001 AY34002 AY35002 Allowable variation of rated input voltage ( at −20 to +55 ℃ ) 90 to 110 % V of rated input voltage Note) This product has a built-in input current limiting resistor; therefore, it is not necessary to externally connect a resistor to the input. The input voltage can be applied directly. ■ Output rating ( per relay, at 25 ℃ ) Part No. Equipped relay Max. load voltage Recommended voltage Continuous load current Peak load currant AY34001 AQZ102 ( DC only ) 60 V ( DC ) 0 to 30 V ( DC ) 2 A ( DC ) 9 A ( 100 ms 1 shot ) AQZ204 ( AC/DC dual use ) 400 V ( DC, AC peak value ) 0 to 200 V ( DC ) 0 to 125 V ( AC ) 0.3 A ( DC, AC peak value ) 1.5 A ( 100 ms 1 shot ) AY34002 AY35001 AY35002 Notes) 1: During 4-point simultaneous operation, the rating per point is also as shown in the table above. 2: The load current varies depending on ambient temperature. Refer to the " REFERENCE DATA Load current vs. ambient temperature characteristics " . SPECIFICATIONS Item Dielectric strength ( initial ) Use condition Conditions 2,000 V AC for 1 min Between different terminals ( between relays, both ways ) 1,500 V AC for 1 min Min. 100 MΩ (Measured portion is the same as the case of dielectric strength. ) Using 500 V DC megger Destructive shock resistance Min. 196 m/s2 In vertical, horizontal and longitudinal directions Destructive vibration resistance 10 to 55 Hz at double amplitude of 1 mm In vertical, horizontal and longitudinal directions Ambient temperature −20 to +55 ℃ Avoid icing and condensation Ambient humidity 35 to 85 % RH Avoid condensation Storage temperature −30 to +80 ℃ Avoid icing and condensation Insulation resistance Shock resistance Specifications Between input and output Terminal screw fasten torque 0.3 to 0.5 N·m ( 3 to 5 kgf·cm ) Cross connection protecting diode 1 A, inverse voltage 400 V Unit weight Approx. 100 g Notes) 1: Dielectric strength and insulation resistance are initial values. 2: Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere. This may cause some troubles like insulation failure of the socket or the PC board. Take care under this condition. 3: Below 0 ℃, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー2ー Panasonic Industry Co., Ltd. 2024 ASCTB9E 202402 RT-3 UNIT RELAY ( PhotoMOS Power type ) /4-POINT TERMINAL ( Without relay type ) REFERENCE DATA 1-1. Load current vs. ambient 1-2. Load current vs. ambient temperature characteristics temperature characteristics Allowable ambient temperature: –20°C to +55°C Allowable ambient temperature: –20°C to +55°C 2 2 AQZ202 Load current, A RT3SP1-12 or 24 V (AQZ102 equipped type) Load current, A AQZ102 1 AQZ105 AQZ205 1 AQZ107 RT3SP2-12 or 24 V (AQZ204 equipped type) AQZ207 AQZ104 AQZ204, AQZ404 -20 -10 0 10 20 30 40 50 Ambient temperature, °C 60 -20 -10 0 10 20 30 40 50 Ambient temperature, °C 60 DIMENSIONS ( Unit: mm ) CAD External dimensions Schematic 7.62 Input terminal socket portion Input side 8.4 R2.1 2-M4 screw mounting position 13+ 14+ 15+ 16+ ķ ķ ķ ķ LED 2 16-M3 terminal screw LED 1 33 ±0.6 6.2 5 + 1ķ 6 + 2ķ LED 4 CAD mark can be downloaded from our Website. LED 3 CAD The CAD data of the products with a 7 8 + 4 ķ 67 ±1 7.4 4.2 +0.3 ķ R3.7 Output side + 3ķ Output terminal socket portion 4 5.5 ±0.6 Note: The polarities of the output terminal socket are for the DC only type (equipped with AQZ 10*) 13.8 With cover removed 30 ±0.6 32 ±1 Mounting hole pattern General tolerance: ± 0.3 2 φ4.3 or M4 30±0.1 GUIDELINES FOR USAGE ■ For cautions for use, please read " GUIDELINES FOR RELAY USAGE " . https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー3ー Panasonic Industry Co., Ltd. 2024 ASCTB9E 202402 CAUTIONS FOR USE RT-3 UNIT RELAY 4-POINT TERMINAL ■ Never install modules ( relays ) into this product other than those designated. Doing so will cause malfunction, breakdown, and breakdown of the connected product. ■ Installing and removing the module 1) Firmly insert the module into the socket with the terminals going in the direction of the blade receptacles. ■ If a unit is dropped, be sure to check its external appearance and characteristics before using it. 2) The module can be easily removed using the removal ■ The operate and release voltage values when equipped with PA-N relays are based on the relay terminals being face down. ( RT-3 Unit relay ( PA-N type ), 4-point Terminal ) If you lose it, you can purchase APA801 separately as key ( APA801 ). The removal key ( APA801 ) is included in 4-point Unit Relay and 4-point Terminal. accessories. ① Insert the removal key ( APA801 ) into the socket slots. ■ Switching lifetime ( PA-N relay ) This characteristic depends on the relay and is effected by coil driving circuit, load type, activation frequency, activation phase, ambient conditions and other factors. Also, be especially careful of loads such as those listed below. 1) When used for AC load-operating and the operating phase is synchronous, rocking and fusing can easily occur due to contact shifting. ② Pull the removal key ( APA801 ) up to remove the module. 2) Frequent switching under load condition When high frequently switched under load condition that can cause arc at the contacts, nitrogen and oxygen in the air is fused by the arc energy and HNO3 is formed. This can corrode metal materials. Three countermeasures for these are listed here. ( 1 ) Incorporate an arc-extinguishing circuit. ( 2 ) Lower the operating frequency ( 3 ) Lower the ambient humidity ③ Slide the removal key ( APA801 ) off of the module. ■ Operating environment 1) Keep the product as far away as possible from power cables, high tension equipment, power equipment, equipment with transmitting devices such as amateur radios, or equipment which generates a large switching surge. 2) The main unit is made of resin; therefor, do not use it in areas where it may come in contact with ( or be exposed to ) organic solvents such as gasoline, thinner, and alcohol, or strong alkaline substances such as ammonia and caustic soda. 3) Do not use the product in areas where it may be exposed to flammable gases, corrosive gases, excessive dust, or moisture, or areas where it may be subjected to strong vibration or shock. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー4ー Panasonic Industry Co., Ltd. 2024 ASCTB371E 202402 CAUTIONS FOR USE RT-3 UNIT RELAY 4-POINT TERMINAL ■ Installation ■ Wiring and circuit configuration 1) Perform mounting hole cutout according to the panel 1) Perform wiring according to the internal schematic. cutout drawings. Take care not to make any mistakes. In particular, with the RT-3 Unit relay ( PA-N relay type ) and 4-point terminal, be careful of the polarity on the output side 2) When installing the unit on a DIN rail, use the DIN rail when equipped with AQZ10*D ( DC type ). Also, locking lever on the side of the unit. Installation is with the RT-3 Unit relay ( PhotoMOS Power type ), be careful of the polarity on the output side of the DC accomplished by simply fitting the unit onto the rail and pressing gently. type ( RT3SP1-**V for type equipped with AQZ102 ). 1. First push in the DIN rail locking lever. 2) We recommend the use of wire-pressed terminals for connection to the terminal portion. DIN rail locking lever ● Example of applicable wire-pressed terminal Company Name Part Name Applicable wirepressed terminal J.S.T. Mfg Co., Ltd. 1.25 to C3A 0.25 to 1.65 mm2 DIN rail 3. Press the unit onto the DIN rail. 2. Hook the holders on the unit over the DIN rail. 3) To remove the unit from the DIN rail, use a flat head screwdriver to pull out the DIN rail locking lever. 3) When the load is inductive, limit spike voltages generated from the load to less than the maximum load voltage. Typical circuits are shown below. ① Add a clamp diode to the load. 3. Remove the unit from the DIN rail. Output terminals 2. Move the screwdriver in the direction of the arrows, and pull out the lever. Load ② Add an R-C snubber to the load. 1. Insert the tip of the flat head screwdriver into the slot in the DIN rail locking lever. Output terminals ■ Transporting and storage Load 1) If the product is subjected to extreme vibration while being transported, the relays may become detached, the lead may become bent, and the unit may become damaged. Handle the carton and case with care. or DC only for AQZ 10*D equipped type ③ Add a varistor between the output terminals. 2) If the product is stored in an extremely adverse environment, visible defects and deterioration of performance characteristics may result. We recommend the following storage conditions. ・Temperature: 5 to 30 ℃ ・Humidity: Max. 60 % R.H. ・Environment: No hazardous substances such as sulfurous acid gases and little dust. Output terminals Load or DC only for AQZ 10*D equipped type 4) Even if spike voltages generated from the load are limited by a clamp diode or R-C snubber, inductances in long circuit wires will still create spike voltages. Keep wires as short as possible to minimize inductance. ■ When equipped with PhotoMOS Power voltage drive type [ RT-3 Unit relay ( PA-N relay type ), 4-point Terminal ] Since the PhotoMOS Power voltage sensitive type does not require the current-controlling resistance on the input side, it can be used together with PA-N relays on RT-3 unit relay ( PA-N relay type ). When connecting PhotoMOS Power voltage sensitive types, since it will be a close connection, it will be necessary to be careful of load currents. Be sure to refer to the information given regarding "Load currents vs ambient temperature characteristics" in the precautions given for use of 4-point terminals. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー5ー Panasonic Industry Co., Ltd. 2024 ASCTB371E 202402 CAUTIONS FOR USE RT-3 UNIT RELAY 4-POINT TERMINAL TERMINAL BLOCK We recommend using wire-pressed terminals for connection to the terminal portion. ● Applicable electrical wire 0.25 to 1.65 mm2 ● Applicable wire-pressed terminals ( mm ) Min. 3 dia. Max. 5.8 Min. 3 4 Max. 5.8 Min. 4.5 4 Company Name Min. 4.5 Part Name Part Name J.S.T. Mfg Co., Ltd. 1.25 to C3A 1.25 to 3 NICHIFU 1.25Y to 3N 1.25 to 3 Nippon Tanshi Co., Ltd. VD1.25 to 3L R1.25 to 3 ACCESSORIES ■ Short circuit plate for RT-3 Unit relay Use when you want to bridge terminals. 〈 With insulator 〉 〈 Without insulator 〉 AY3803 AY3802 External dimensions ( mm ) External dimensions ( mm ) 28.7 28.7 7.62 ±0.3 7.62 ±0.3 5.8 ±0.1 5.8 ±0.1 0.5 3.1 ±0.1 0.5 3.1 ±0.1 R R 17.8 13.8 17 8 13 +0 -3 1.5 to 2.5 26.5 28 +0.5 -1 General tolerance: ± 0.5 General tolerance: ±0.5 Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー6ー Panasonic Industry Co., Ltd. 2024 ASCTB371E 202402 ■ Global Sales Network Information: industrial.panasonic.com/ac/e/salesnetwork Electromechanical Control Business Division 1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan industrial.panasonic.com/ac/e/ ©Panasonic Industry Co., Ltd. 2024 Specifications are subject to change without notice. モヴヤヵャペユチチチビパビフパビ 2024.2
RT3SP1-12V 价格&库存

很抱歉,暂时无法提供与“RT3SP1-12V”相匹配的价格&库存,您可以联系我们找货

免费人工找货