RT-3 Unit Relay/4-point Terminal (Power PhotoMOS Relay type)
Slim, Space-saving,
4-point Unit Relay
RT-3 UNIT RELAY
4-POINT TERMINAL
(Power PhotoMOS Relay type)
FEATURES
New
1. Space-saving type with four independent points on a
base measuring 33 × 67 mm 1.299 × 2.638 inch. Contributes
to a more compact control panel.
2. Power PhotoMOS relays, for high reliability and long life,
are installed.
This type is equipped with Power PhotoMOS relays which have
a reputation for high reliability and long life. Helps make devices
maintenance-free.
3. Can be mounted on a DIN rail or mounted directly (by
screws).
4. Equipped with an LED display to allow easy confirmation
of operation.
5. Possible to select relay for use in the 4-point terminal in
accordance with load.
4-point Terminal
(Power PhotoMOS relay type)
Mountable relay
RT-3 Unit relay
Power PhotoMOS relay
Compliance with RoHS Directive
TYPES
1. RT-3 Unit relay
Contact arrangement
1 Form A × 4
Type
Rated input voltage
Part No.
DC only
(Equipped with AQZ102)
12 V DC
24 V DC
RT3SP1-12V
RT3SP1-24V
AC/DC dual use
(Equipped with AQZ204)
12 V DC
24 V DC
RT3SP2-12V
RT3SP2-24V
Standard packing: Carton: 1 pc.; Case: 20 pcs.
Notes: 1. Only for use with Power PhotoMOS standard type relays. Cannot be equipped with PA relays.
2. Please inquire other contact arrangement.
2. 4-point Terminal
Type
New
Rated input voltage
12 V DC
24 V DC
Power PhotoMOS relay type
Part No.
RT3BB12V
RT3BB24V
Standard packing: Carton: 1 pc.; Case: 20 pcs.
3. Mountable relays for 4-point Terminal (per relay, at 25°C 77°F, initial)
Possible relays
Output
Type
Part No.
Maximum load
voltage
Power PhotoMOS Relay
(DC only)
AQZ102
AQZ105
AQZ107
AQZ104
60V DC
100V DC
200V DC
400V DC
0 to 30V DC
0 to 50V DC
0 to 100V DC
0 to 200V DC
2.00A
1.50A
0.70A
0.40A
9.0A
6.0A
3.0A
1.5A
Power PhotoMOS Relay
(AC/DC dual use)
AQZ202
AQZ205
AQZ207
AQZ204
AQZ404 (1 Form B type)
60V (peak)
100V (peak)
200V (peak)
400V (peak)
400V (peak)
0 to 12V AC/0 to 30V DC
0 to 24V AC/0 to 50V DC
0 to 48V AC/0 to 100V DC
0 to 125V AC/0 to 200V DC
0 to 125V AC/0 to 200V DC
1.80A
1.20A
0.60A
0.30A
0.50A
9.0A
6.0A
3.0A
1.5A
1.5A
Recommended load voltage
Continuous load
current
Peak load current
Notes: 1. Peak load current is limited to “100 ms, 1 shot”.
2. The ratings per point in the table above also apply during 4-point simultaneous operation.
3. Please use a load current that is within the range of the data given below in “REFERENCE DATA 2. Load current vs. ambient temperature characteristics”.
4. Be very careful regarding the polarity on the output side when equipped with AQZ10∗ (dedicated power PhotoMOS DC type).
5. Never equip a product with a relay other than those given above. Doing so can cause product malfunction, breakdown, and breakdown of connected devices.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
RT-3 Unit Relay/4-point Terminal (Power PhotoMOS Relay type)
RATING
1. Input ratings (per relay)
Part No.
RT3SP1-12V
RT3SP2-12V
RT3SP1-24V
RT3SP2-24V
Rated input voltage
Operate voltage
(at 25°C 77°F)
Release voltage
(at 25°C 77°F)
Input current
(during application of rated
input voltage)
(at 25°C 77°F)
12 V DC
Max. 9.5 V DC
(5.1 V typ.)
Min. 3.0 V DC
(5.0 V typ.)
6.2 mA typ.
24 V DC
Max. 15.0 V DC
(6.8 V typ.)
Min. 3.5 V DC
(6.5 V typ.)
6.7 mA typ.
Allowable variation of rated
input voltage
(at –20°C to +55°C
–4°F to +131°F)
90% to 110% of rated input
voltage
Note: This product has a built-in input current limiting resistor; therefore, it is not necessary to externally connect a resistor to the input. The input voltage can be applied
directly.
2. Output ratings (per relay, at 25°C 77°F)
Part No.
RT3SP1-12V
RT3SP1-24V
RT3SP2-12V
RT3SP2-24V
Equipped relay
Maximum load voltage
Recommended voltage
Continuous load current
Peak load currant
AQZ102
(DC only)
60 V
(DC)
0 to 30 V (DC)
2 A (DC)
9A
(100 ms 1 shot)
AQZ204
(AC/DC dual use)
400 V
(DC, AC peak value)
0 to 200 V (DC)
0 to 125 V (AC)
0.3 A
(DC, AC peak value)
1.5 A
(100 ms 1 shot)
Notes: 1. During 4-point simultaneous operation, the rating per point is also as shown above.
2. The load current varies depending on ambient temperature. Refer to the “REFERENCE DATA 2. Load current vs. ambient temperature characteristics”.
SPECIFICATIONS
Item
Between input and output
Breakdown voltage
Between different terminals
(between relays, both ways)
Insulation resistance
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Storage temperature
Terminal screw fasten torque
Cross connection protecting diode
Unit weight
Specifications
2,000 Vrms for 1 min.
1,500 Vrms for 1 min.
Min. 100 MΩ (Using 500 V DC megger, Measurement at same location as “Breakdown voltage” section.)
10 to 55 Hz at double amplitude 1 mm .039 inch
Min. 196 m/s2
–20°C to +55°C –4°F to +131°F
35% to 85% R.H. (Not condensing)
–30°C to +80°C –22°F to +176°F (Not freezing and condensing)
0.3 to 0.5 N·m {3 to 5 kgf·cm}
1.5 A, inverse voltage 40 V
Approx. 100 g 3.53 oz
Notes: 1. The value of breakdown voltage and insulation resistance is the initial one.
2. Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere. This may cause some
troubles like insulation failure of the socket or the print circuit board. Take care under this condition.
3. Below 0°C 32°F, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition.
REFERENCE DATA
1. Load current vs. ambient temperature
characteristics (1)
2. Load current vs. ambient temperature
characteristics (2)
Allowable ambient temperature: –20°C to +55°C
–4°F to +131°F
Allowable ambient temperature: –20°C to +55°C
–4°F to +131°F
2
RT3SP1-12 or 24 V
(AQZ102 equipped type)
1
RT3SP2-12 or 24 V
(AQZ204 equipped type)
AQZ102
AQZ202
Load current, A
Load current, A
2
AQZ105
AQZ205
1
AQZ107
AQZ207 AQZ104
AQZ204, AQZ404
–20 –10 0
10 20 30 40 50 60
–4 14 32 50 68 86 104 122 140
Ambient temperature, °C °F
–20 –10 0
10 20 30 40 50 60
–4 14 32 50 68 86 104 122 140
Ambient temperature, °C °F
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
RT-3 Unit Relay/4-point Terminal (Power PhotoMOS Relay type)
DIMENSIONS (mm inch)
1. External dimensions
7.62
.300
2. Schematic
Input terminal socket portion
33±0.6
1.299±.024
6.2
.244
16-M3 .118 terminal screw
Input side
13+
14+
15+
16+
9–
10–
11–
12–
LED4
LED3
LED2
LED1
8.4 .331
R2.1 .083
2-M4 .157 screw
mounting position
67±1
2.638±.039
7.4
.291
4.2+0.3
−0.1
.165+.012
−.004
R3.7 .146
Output side
5+
6+
7+
8+
1–
2–
3–
4–
Output terminal socket portion
With cover removed
5.5±0.6
.217±.024
4
.157
Note: The polarities of the output terminal socket are
for the DC only type (equipped with AQZ102)
13.8
.543
3. Mounting hole pattern
32±1
1.260±.039
30±0.6
1.181±.024
2-4.3 dia. or M4
2-.169 dia. or M.157
30±0.1
1.181±.004
General tolerance: ±0.3 ±.012
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
CAUTIONS FOR USE
CAUTIONS FOR USE
1. Never install modules (relays) into
this product other than those
designated. Doing so will cause
malfunction, breakdown, and
breakdown of the connected product.
2. If a unit is dropped be sure to check
its external appearance and
characteristics before using it.
3. The operation and return voltage
values when equipped with PA relays
are based on the relay terminals being
face down. (RT-3 Unit relay (PA type),
4-point Terminal)
4. Switching lifetime (PA relay)
This characteristic depends on the relay
and is effected by coil driving circuit, load
type, activation frequency, activation
phase, ambient conditions and other
factors.
Also, be especially careful of loads such
as those listed below.
1) When used for AC load-operating and
the operating phase is synchronous,
rocking and fusing can easily occur due
to contact shifting.
2) Frequent switching under load
condition
When high frequently switched under
load condition that can cause arc at the
contacts, nitrogen and oxygen in the air is
fused by the arc energy and HNO3 is
formed. This can corrode metal materials.
Three countermeasures for these are
listed here.
(1) Incorporate an arc-extinguishing
circuit.
(2) Lower the operating frequency
(3) Lower the ambient humidity
5. Operating environment
1) Keep the product as far way as
possible from power cables, high tension
equipment, power equipment, equipment
with transmitting devices such as
amateur radios, or equipment which
generates a large switching surge.
2) The main unit is made of resin;
therefore, do not use it in areas where it
may come in contact with (or be exposed
to) organic solvents such as gasoline,
thinner, and alcohol, or strong alkaline
substances such as ammonia and
caustic soda.
3) Do not use the product in areas where
it may be exposed to flammable gases,
corrosive gases, excessive dust, or
moisture, or areas where it may be
subjected to strong vibration or shock.
6. Installing and removing the module
1) Firmly insert the module into the
socket with the terminals going in the
direction of the blade receptacles.
2) The module can be easily removed
using the removal key.
(1) Insert the removal key into the socket
slots.
RT-3 UNIT RELAY
4-POINT TERMINAL
2) We recommend the use of wirepressed terminals for connection to the
terminal portion.
• Example of applicable wire-pressed
terminal
Company
Name
Part Name
Applicable wirepressed terminal
J.S.T. Mfg
Co., Ltd.
1.25 to C3A
0.25 to 1.65mm2
3) When the load is inductive, limit spike
voltages generated from the load to less
than the maximum load voltage.
Typical circuits are shown below.
(1) Add a clamp diode to the load.
Output terminals
Load
(2) Pull the removal key up to remove the
module.
(2) Add an R-C snubber to the load.
Output terminals
Load
or
DC only for AQZ10∗D
equipped type
(3) Slide the removal key off of the
module.
(3) Add a varistor between the output
terminals.
Output terminals
Load
or
DC only for AQZ10∗D
equipped type
7. Wiring and circuit configuration
1) Perform wiring according to the
internal schematic. Take care not to make
any mistakes.
In particular, with the RT-3 Unit relay (PA
relay type) and 4-point terminal, be
careful of the polarity on the output side
when equipped with AQZ10∗D (DC type).
Also, with the RT-3 Unit relay (Power
PhotoMOS relay type), be careful of the
polarity on the output side of the DC type
(RT3SP1-∗∗V for type equipped with
AQZ102).
4) Even if spike voltages generated from
the load are limited by a clamp diode or
R-C snubber, inductances in long circuit
wires will still create spike voltages.
Keep wires as short as possible to
minimize inductance.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
CAUTIONS FOR USE
8. Installation
1) Perform mounting hole cutout
according to the panel cutout drawings.
2) When installing the unit on a DIN rail,
use the DIN rail locking lever on the side
of the unit. Installation is accomplished by
simply fitting the unit onto the rail and
pressing gently.
1 First push in
the DIN rail
locking lever.
DIN rail locking lever
DIN rail
3 Press the unit onto
the DIN rail.
2 Hook the holders on the
unit over the DIN rail.
3) To remove the unit from the DIN rail,
use a flat head screwdriver to pull out the
DIN rail locking lever.
9. Transporting and storage
1) If the product is subjected to extreme
vibration while being transported, the
relays may become detached, the lead
may become bent, and the unit may
become damaged. Handle the carton
and case with care.
2) If the product is stored in an extremely
adverse environment, visible defects and
deterioration of performance
characteristics may result. We
recommend the following storage
conditions.
• Temperature: 5 to 30°C 41 to 86°F
• Humidity: Max. 60% R.H.
• Environment: No hazardous
substances such as sulfurous acid
gases and little dust.
10. When equipped with Power
PhotoMOS relay voltage drive type
[RT-3 Unit relay (PA relay type), 4-point
Terminal]
Since the Power PhotoMOS relay voltage
sensitive type does not require the
current-controlling resistance on the input
side, it can be used together with PA
relays on RT-3 unit relay (PA relay type)
or RT-2 relay terminals.
When connecting Power PhotoMOS relay
voltage sensitive types, since it will be a
close connection, it will be necessary to
be careful of load currents. Be sure to
refer to the information given regarding
“Load currents vs ambient temperature
characteristics” in the precautions given
for use of 4-point terminals.
3 Remove the unit from
the DIN rail.
2 Move the
screwdriver in
the direction of
the arrows, and
pull out the lever.
1 Insert the tip of the flat head screwdriver
into the slot in the DIN rail locking lever.
TERMINAL BLOCK
We recommend using wire-pressed terminals for connection to the terminal portion.
• Applicable electrical wire: 0.25 to 1.65 mm2 .01 to .065 inch
• Applicable wire-pressed terminals (mm inch)
3 dia. min.
.118 dia. min.
5.6 max.
.220 max. 3 min.
.118 min.
5.6 max.
.220 max.
4
4.5 min.
.157 .177 min.
Company Name
J.S.T. Mfg Co., Ltd.
NICHIFU
Nippon Tanshi Co., Ltd.
4
4.5 min.
.157 .117 min.
Part Name
1.25 to C3A
1.25Y to 3N
VD1.25 to 3
Part Name
1.25 to 3
1.25 to 3
R1.25 to 3
ACCESSORIES
Short circuit plate for RT-3 Unit relay
Use when you want to bridge terminals.
< With insulator >
< Without insulator >
AY3802
External dimensions (mm inch)
28.7
1.130
7.62±0.3
.300±.012
5.8±0.1
.228±.004
3.1±0.1
.122±.004
0.5
.020
AY3803
External dimensions (mm inch)
28.7
1.130
7.62±0.3
.300±.012
5.8±0.1
.228±.004
3.1±0.1
.122±.004
R
0.5
.020
R
17.8
.701
13.8
.543
+0
8−3
.315+0
−.118
28+0.5
−1
1.102+.020
−.039
General tolerance: ±0.5 ±.020
17
.669
13
.512
1.5 to 2.5
.059 to .098
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
26.5
1.043
General tolerance: ±0.5 ±.020