RT-3 Unit Relay/4-point Terminal (Power PhotoMOS Relay type) Slim, Space-saving, 4-point Unit Relay RT-3 UNIT RELAY 4-POINT TERMINAL (Power PhotoMOS Relay type) FEATURES New 1. Space-saving type with four independent points on a base measuring 33 × 67 mm 1.299 × 2.638 inch. Contributes to a more compact control panel. 2. Power PhotoMOS relays, for high reliability and long life, are installed. This type is equipped with Power PhotoMOS relays which have a reputation for high reliability and long life. Helps make devices maintenance-free. 3. Can be mounted on a DIN rail or mounted directly (by screws). 4. Equipped with an LED display to allow easy confirmation of operation. 5. Possible to select relay for use in the 4-point terminal in accordance with load. 4-point Terminal (Power PhotoMOS relay type) Mountable relay RT-3 Unit relay Power PhotoMOS relay Compliance with RoHS Directive TYPES 1. RT-3 Unit relay Contact arrangement 1 Form A × 4 Type Rated input voltage Part No. DC only (Equipped with AQZ102) 12 V DC 24 V DC RT3SP1-12V RT3SP1-24V AC/DC dual use (Equipped with AQZ204) 12 V DC 24 V DC RT3SP2-12V RT3SP2-24V Standard packing: Carton: 1 pc.; Case: 20 pcs. Notes: 1. Only for use with Power PhotoMOS standard type relays. Cannot be equipped with PA relays. 2. Please inquire other contact arrangement. 2. 4-point Terminal Type New Rated input voltage 12 V DC 24 V DC Power PhotoMOS relay type Part No. RT3BB12V RT3BB24V Standard packing: Carton: 1 pc.; Case: 20 pcs. 3. Mountable relays for 4-point Terminal (per relay, at 25°C 77°F, initial) Possible relays Output Type Part No. Maximum load voltage Power PhotoMOS Relay (DC only) AQZ102 AQZ105 AQZ107 AQZ104 60V DC 100V DC 200V DC 400V DC 0 to 30V DC 0 to 50V DC 0 to 100V DC 0 to 200V DC 2.00A 1.50A 0.70A 0.40A 9.0A 6.0A 3.0A 1.5A Power PhotoMOS Relay (AC/DC dual use) AQZ202 AQZ205 AQZ207 AQZ204 AQZ404 (1 Form B type) 60V (peak) 100V (peak) 200V (peak) 400V (peak) 400V (peak) 0 to 12V AC/0 to 30V DC 0 to 24V AC/0 to 50V DC 0 to 48V AC/0 to 100V DC 0 to 125V AC/0 to 200V DC 0 to 125V AC/0 to 200V DC 1.80A 1.20A 0.60A 0.30A 0.50A 9.0A 6.0A 3.0A 1.5A 1.5A Recommended load voltage Continuous load current Peak load current Notes: 1. Peak load current is limited to “100 ms, 1 shot”. 2. The ratings per point in the table above also apply during 4-point simultaneous operation. 3. Please use a load current that is within the range of the data given below in “REFERENCE DATA 2. Load current vs. ambient temperature characteristics”. 4. Be very careful regarding the polarity on the output side when equipped with AQZ10∗ (dedicated power PhotoMOS DC type). 5. Never equip a product with a relay other than those given above. Doing so can cause product malfunction, breakdown, and breakdown of connected devices. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. RT-3 Unit Relay/4-point Terminal (Power PhotoMOS Relay type) RATING 1. Input ratings (per relay) Part No. RT3SP1-12V RT3SP2-12V RT3SP1-24V RT3SP2-24V Rated input voltage Operate voltage (at 25°C 77°F) Release voltage (at 25°C 77°F) Input current (during application of rated input voltage) (at 25°C 77°F) 12 V DC Max. 9.5 V DC (5.1 V typ.) Min. 3.0 V DC (5.0 V typ.) 6.2 mA typ. 24 V DC Max. 15.0 V DC (6.8 V typ.) Min. 3.5 V DC (6.5 V typ.) 6.7 mA typ. Allowable variation of rated input voltage (at –20°C to +55°C –4°F to +131°F) 90% to 110% of rated input voltage Note: This product has a built-in input current limiting resistor; therefore, it is not necessary to externally connect a resistor to the input. The input voltage can be applied directly. 2. Output ratings (per relay, at 25°C 77°F) Part No. RT3SP1-12V RT3SP1-24V RT3SP2-12V RT3SP2-24V Equipped relay Maximum load voltage Recommended voltage Continuous load current Peak load currant AQZ102 (DC only) 60 V (DC) 0 to 30 V (DC) 2 A (DC) 9A (100 ms 1 shot) AQZ204 (AC/DC dual use) 400 V (DC, AC peak value) 0 to 200 V (DC) 0 to 125 V (AC) 0.3 A (DC, AC peak value) 1.5 A (100 ms 1 shot) Notes: 1. During 4-point simultaneous operation, the rating per point is also as shown above. 2. The load current varies depending on ambient temperature. Refer to the “REFERENCE DATA 2. Load current vs. ambient temperature characteristics”. SPECIFICATIONS Item Between input and output Breakdown voltage Between different terminals (between relays, both ways) Insulation resistance Vibration resistance Shock resistance Ambient temperature Ambient humidity Storage temperature Terminal screw fasten torque Cross connection protecting diode Unit weight Specifications 2,000 Vrms for 1 min. 1,500 Vrms for 1 min. Min. 100 MΩ (Using 500 V DC megger, Measurement at same location as “Breakdown voltage” section.) 10 to 55 Hz at double amplitude 1 mm .039 inch Min. 196 m/s2 –20°C to +55°C –4°F to +131°F 35% to 85% R.H. (Not condensing) –30°C to +80°C –22°F to +176°F (Not freezing and condensing) 0.3 to 0.5 N·m {3 to 5 kgf·cm} 1.5 A, inverse voltage 40 V Approx. 100 g 3.53 oz Notes: 1. The value of breakdown voltage and insulation resistance is the initial one. 2. Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere. This may cause some troubles like insulation failure of the socket or the print circuit board. Take care under this condition. 3. Below 0°C 32°F, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition. REFERENCE DATA 1. Load current vs. ambient temperature characteristics (1) 2. Load current vs. ambient temperature characteristics (2) Allowable ambient temperature: –20°C to +55°C –4°F to +131°F Allowable ambient temperature: –20°C to +55°C –4°F to +131°F 2 RT3SP1-12 or 24 V (AQZ102 equipped type) 1 RT3SP2-12 or 24 V (AQZ204 equipped type) AQZ102 AQZ202 Load current, A Load current, A 2 AQZ105 AQZ205 1 AQZ107 AQZ207 AQZ104 AQZ204, AQZ404 –20 –10 0 10 20 30 40 50 60 –4 14 32 50 68 86 104 122 140 Ambient temperature, °C °F –20 –10 0 10 20 30 40 50 60 –4 14 32 50 68 86 104 122 140 Ambient temperature, °C °F All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. RT-3 Unit Relay/4-point Terminal (Power PhotoMOS Relay type) DIMENSIONS (mm inch) 1. External dimensions 7.62 .300 2. Schematic Input terminal socket portion 33±0.6 1.299±.024 6.2 .244 16-M3 .118 terminal screw Input side 13+ 14+ 15+ 16+ 9– 10– 11– 12– LED4 LED3 LED2 LED1 8.4 .331 R2.1 .083 2-M4 .157 screw mounting position 67±1 2.638±.039 7.4 .291 4.2+0.3 −0.1 .165+.012 −.004 R3.7 .146 Output side 5+ 6+ 7+ 8+ 1– 2– 3– 4– Output terminal socket portion With cover removed 5.5±0.6 .217±.024 4 .157 Note: The polarities of the output terminal socket are for the DC only type (equipped with AQZ102) 13.8 .543 3. Mounting hole pattern 32±1 1.260±.039 30±0.6 1.181±.024 2-4.3 dia. or M4 2-.169 dia. or M.157 30±0.1 1.181±.004 General tolerance: ±0.3 ±.012 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. CAUTIONS FOR USE CAUTIONS FOR USE 1. Never install modules (relays) into this product other than those designated. Doing so will cause malfunction, breakdown, and breakdown of the connected product. 2. If a unit is dropped be sure to check its external appearance and characteristics before using it. 3. The operation and return voltage values when equipped with PA relays are based on the relay terminals being face down. (RT-3 Unit relay (PA type), 4-point Terminal) 4. Switching lifetime (PA relay) This characteristic depends on the relay and is effected by coil driving circuit, load type, activation frequency, activation phase, ambient conditions and other factors. Also, be especially careful of loads such as those listed below. 1) When used for AC load-operating and the operating phase is synchronous, rocking and fusing can easily occur due to contact shifting. 2) Frequent switching under load condition When high frequently switched under load condition that can cause arc at the contacts, nitrogen and oxygen in the air is fused by the arc energy and HNO3 is formed. This can corrode metal materials. Three countermeasures for these are listed here. (1) Incorporate an arc-extinguishing circuit. (2) Lower the operating frequency (3) Lower the ambient humidity 5. Operating environment 1) Keep the product as far way as possible from power cables, high tension equipment, power equipment, equipment with transmitting devices such as amateur radios, or equipment which generates a large switching surge. 2) The main unit is made of resin; therefore, do not use it in areas where it may come in contact with (or be exposed to) organic solvents such as gasoline, thinner, and alcohol, or strong alkaline substances such as ammonia and caustic soda. 3) Do not use the product in areas where it may be exposed to flammable gases, corrosive gases, excessive dust, or moisture, or areas where it may be subjected to strong vibration or shock. 6. Installing and removing the module 1) Firmly insert the module into the socket with the terminals going in the direction of the blade receptacles. 2) The module can be easily removed using the removal key. (1) Insert the removal key into the socket slots. RT-3 UNIT RELAY 4-POINT TERMINAL 2) We recommend the use of wirepressed terminals for connection to the terminal portion. • Example of applicable wire-pressed terminal Company Name Part Name Applicable wirepressed terminal J.S.T. Mfg Co., Ltd. 1.25 to C3A 0.25 to 1.65mm2 3) When the load is inductive, limit spike voltages generated from the load to less than the maximum load voltage. Typical circuits are shown below. (1) Add a clamp diode to the load. Output terminals Load (2) Pull the removal key up to remove the module. (2) Add an R-C snubber to the load. Output terminals Load or DC only for AQZ10∗D equipped type (3) Slide the removal key off of the module. (3) Add a varistor between the output terminals. Output terminals Load or DC only for AQZ10∗D equipped type 7. Wiring and circuit configuration 1) Perform wiring according to the internal schematic. Take care not to make any mistakes. In particular, with the RT-3 Unit relay (PA relay type) and 4-point terminal, be careful of the polarity on the output side when equipped with AQZ10∗D (DC type). Also, with the RT-3 Unit relay (Power PhotoMOS relay type), be careful of the polarity on the output side of the DC type (RT3SP1-∗∗V for type equipped with AQZ102). 4) Even if spike voltages generated from the load are limited by a clamp diode or R-C snubber, inductances in long circuit wires will still create spike voltages. Keep wires as short as possible to minimize inductance. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. CAUTIONS FOR USE 8. Installation 1) Perform mounting hole cutout according to the panel cutout drawings. 2) When installing the unit on a DIN rail, use the DIN rail locking lever on the side of the unit. Installation is accomplished by simply fitting the unit onto the rail and pressing gently. 1 First push in the DIN rail locking lever. DIN rail locking lever DIN rail 3 Press the unit onto the DIN rail. 2 Hook the holders on the unit over the DIN rail. 3) To remove the unit from the DIN rail, use a flat head screwdriver to pull out the DIN rail locking lever. 9. Transporting and storage 1) If the product is subjected to extreme vibration while being transported, the relays may become detached, the lead may become bent, and the unit may become damaged. Handle the carton and case with care. 2) If the product is stored in an extremely adverse environment, visible defects and deterioration of performance characteristics may result. We recommend the following storage conditions. • Temperature: 5 to 30°C 41 to 86°F • Humidity: Max. 60% R.H. • Environment: No hazardous substances such as sulfurous acid gases and little dust. 10. When equipped with Power PhotoMOS relay voltage drive type [RT-3 Unit relay (PA relay type), 4-point Terminal] Since the Power PhotoMOS relay voltage sensitive type does not require the current-controlling resistance on the input side, it can be used together with PA relays on RT-3 unit relay (PA relay type) or RT-2 relay terminals. When connecting Power PhotoMOS relay voltage sensitive types, since it will be a close connection, it will be necessary to be careful of load currents. Be sure to refer to the information given regarding “Load currents vs ambient temperature characteristics” in the precautions given for use of 4-point terminals. 3 Remove the unit from the DIN rail. 2 Move the screwdriver in the direction of the arrows, and pull out the lever. 1 Insert the tip of the flat head screwdriver into the slot in the DIN rail locking lever. TERMINAL BLOCK We recommend using wire-pressed terminals for connection to the terminal portion. • Applicable electrical wire: 0.25 to 1.65 mm2 .01 to .065 inch • Applicable wire-pressed terminals (mm inch) 3 dia. min. .118 dia. min. 5.6 max. .220 max. 3 min. .118 min. 5.6 max. .220 max. 4 4.5 min. .157 .177 min. Company Name J.S.T. Mfg Co., Ltd. NICHIFU Nippon Tanshi Co., Ltd. 4 4.5 min. .157 .117 min. Part Name 1.25 to C3A 1.25Y to 3N VD1.25 to 3 Part Name 1.25 to 3 1.25 to 3 R1.25 to 3 ACCESSORIES Short circuit plate for RT-3 Unit relay Use when you want to bridge terminals. < With insulator > < Without insulator > AY3802 External dimensions (mm inch) 28.7 1.130 7.62±0.3 .300±.012 5.8±0.1 .228±.004 3.1±0.1 .122±.004 0.5 .020 AY3803 External dimensions (mm inch) 28.7 1.130 7.62±0.3 .300±.012 5.8±0.1 .228±.004 3.1±0.1 .122±.004 R 0.5 .020 R 17.8 .701 13.8 .543 +0 8−3 .315+0 −.118 28+0.5 −1 1.102+.020 −.039 General tolerance: ±0.5 ±.020 17 .669 13 .512 1.5 to 2.5 .059 to .098 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 26.5 1.043 General tolerance: ±0.5 ±.020
RT3SP2-24V 价格&库存

很抱歉,暂时无法提供与“RT3SP2-24V”相匹配的价格&库存,您可以联系我们找货

免费人工找货
RT3SP2-24V

    库存:0