RX-500G

RX-500G

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SENSOR PHOTO 500MM 12-24VDC NPN

  • 数据手册
  • 价格&库存
RX-500G 数据手册
389 Robust Photoelectric Sensor RX SERIES FIBER SENSORS Related Information Amplifier Built-in ■■General terms and conditions............ F-17 ■■Glossary of terms........................ P.1359~ ■■Sensor selection guide................... P.283~ ■■General precautions....................... P.1405 LASER SENSORS PHOTOELECTRIC SENSORS Conforming to EMC Directive (Excluding RX2 and RX4) MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS diagnosis MEASUREMENT SENSORS panasonic-electric-works.net/sunx Self-diagnosis Test input Interference prevention STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS Sturdy photoelectric sensor made of die-cast zinc alloy Robust HUMAN MACHINE INTERFACES The enclosure is robust as it is made of die-cast zinc alloy. ENERGY CONSUMPTION VISUALIZATION COMPONENTS VARIETIES FA COMPONENTS Standard type MACHINE VISION SYSTEMS UV CURING SYSTEMS RX Wide variety Thru-beam type Diffuse reflective type Retroreflective type Sensing object Longest range: 5 m 16.404 ft Longest range: 50 m 164.042 ft Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated CX-400 EX-10 EX-20 EX-30 EX-40 CX-440 Standard (Infrared)...10 m 32.808 ft Long sensing range (Infrared)...50 m 164.042 ft Visible light (Red) ...2 m 6.562 ft Visible light (Green)...500 mm 19.685 in MQ-W RX-LS200 RX RT-610 Long sensing range (Infrared)...700 mm 27.559 in Visible light (Red)...200 mm 7.874 in DC 2-wire type RX2 RX4 Heavy duty type Wiring reduced by 1/3 Durable against oil Wiring can be completed by using only two, instead of three wires. This sensor can be used in a harsh environment. Indicator cover (Polyethersulphone) Power supply cost: reduced to 1/30 or less Current consumption: 1 mA or less An additional power supply for the sensors is not required. EQ-30 EQ-500 For specular object sensing (with polarizing filters, red) ...0.1 to 3 m 0.328 to 9.843 ft For transparent object sensing (with polarizing filters, red) ... 500 mm 19.685 in Long sensing range(Infrared) ... 0.1 to 5 m 0.328 to 16.404 ft Longest range: 700 mm 27.559 in Enclosure: Fluorine resin coating Lens: Polyalylate Oil resistant cable IP67g (JEM) Oil resistant protective tube MAINTENANCE FUNCTIONS Test input (emission halt input) Automatic interference prevention function Retroreflective / diffuse reflective types Convenient for operation check before start-up. (Excluding RX2 types) Two sensors can be mounted side by side because of the automatic There is no problem interference prevention even if the beam of the function. (Excluding RX2 types) adjoining sensor is incident. Robust Photoelectric Sensor RX SERIES APPLICATIONS 390 FIBER SENSORS Detecting engines Confirming car position at parking garage Sensing machine tools LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS RX-M10 RX4-M5 AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS RX-PRVM3 INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS ORDER GUIDE Type SENSOR OPTIONS Appearance Sensing range 10 m 32.808 ft For mark sensing Long sensing range 50 m 164.062 ft Red 2 m 6.562 ft Green 500 mm 19.685 in Red (with polarizing filters) 0.1 to 3 m 0.328 to 9.843 ft (Note 1) Infrared (long sensing range) 0.1 to 5 m 0.328 to 16.404 ft (Note 1) Infrared 700 mm 27.559 in Red 5 m 16.404 ft Red (with polarizing filters) Output MEASUREMENT SENSORS RX-M50 STATIC CONTROL DEVICES RX-M2R ENDOSCOPE RX-500G RX-PRVM3 0.1 to 2 m 0.328 to 6.562 ft (Note 1) NPN open-collector transistor RX-RVM5 LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES RX-D700 ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS RX2-M5 RX2-PRVM2 SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS RX-M10 RX-D200R 200 mm 7.874 in Infrared UV CURING SYSTEMS Non contact DC 2-wire type Selection Guide Amplifier Built-in Power Supply Built-in 300 mm 11.811 in Infrared Amplifierseparated RX2-D300 CX-400 Infrared Diffuse reflective Retroreflective Diffuse reflective Retroreflective Thru-beam RX4 (Heavy duty type) RX2 (DC 2-wire type) Thru-beam RX (Standard type) Thru-beam Infrared Model No. (Note 2) 2 m 6.562 ft cable length 3 m 9.843 ft cable length 5 m 16.404 ft cable length RX4-M5 5 m 16.404 ft RX4-M5-C3 RX4-M5-C5 EX-10 NPN open-collector transistor Notes: 1) The sensing range of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range of RX-PRVM3, RX-RVM5 and RX2-PRVM2 is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Reflector cannot be placed in this range Sensor Actual sensing range 3 m 9.843 ft of the sensor RX-RVM5: 5 m 16.404 ft 0.1 m 0.328 ft RX2-PRVM2: 2 m 6.562 ft Setting range of the reflector ( Reflector ) Reflector 2) The model No. with “P” shown on the label affixed to the thru-beam type sensor is the emitter, “D” shown on the label is the receiver. (e.g.) Emitter of RX-M10: RX-M10P, Receiver of RX-M10: RX-M10D EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 391 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Robust Photoelectric Sensor RX SERIES ORDER GUIDE 5 m 16.404 ft cable length type 5m 16.404 ft cable length type (standard: 2m 6.562 ft) is also available for RX and RX2 types. (excluding RX-500G) When ordering this type, suffix “-C5” to the model No. (e.g.) 5 m 16.404 ft cable length type of RX-M10 is “RX-M10-C5”. Accessories • MS-RX-1 (Sensor mounting bracket) • MS-RX-2 (Sensor mounting bracket) • PT-RX4-1 (Oil resistant protective tube 1 m 3.281 ft long) • PT-RX4-2 (Oil resistant protective tube 2 m 6.562 ft long) • PT-RX4-4 (Oil resistant protective tube 4 m 13.123 ft long) • RF-230 (Reflector) • MS-RX-1 • MS-RX-2 Two M4 (Iength 16 mm 0.630 in) hexagon-socket-head bolts are attached Two M4 (Iength 16 mm 0.630 in) hexagon-socket-head bolts are attached SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated CX-400 EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 • PT-RX4-□ • RF-230 PT-RX4-□ Robust Photoelectric Sensor 392 RX SERIES OPTIONS Designation FIBER SENSORS Model No. OS-RX-05×5 Description Slit on emitter • Sensing range: 2.7 m 8.858 ft [RX-M10] 1.4 m 4.593 ft [RX2-M5] • Min. sensing object: ø8 mm ø0.315 in Slit on receiver • Sensing range: 1.9 m 6.234 ft [RX-M10] 1 m 3.281 ft [RX2-M5] • Min. sensing object: ø6 mm ø0.236 in Slit size 0.5 × 5 mm 0.020 × 0.197 in OS-RX-5×05 Slit size 5 × 0.5 mm 0.197 × 0.020 in OS-RX-1×5 Slit size 1 × 5 mm 0.039 × 0.197 in Slit on receiver OS-RX-5×1 Slit size 5 × 1 mm 0.197 × 0.039 in OS-RX-3×5 Slit size 3 × 5 mm 0.118 × 0.197 in OS-RX-5×3 Slit size 5 × 3 mm 0.197 × 0.118 in Reflector For retroreflective type sensor only (Note 1) Reflector mounting bracket (Note 1) Reflective tape For RX-RVM5 only Protective tube Sensor checker Slit on emitter • Sensing range: 3.8 m 12.467 ft [RX-M10] 1.9 m 6.234 ft [RX2-M5] • Min. sensing object: ø8 mm ø0.315 in Slit on emitter • Sensing range: 7 m 22.966 ft [RX-M10] 3.5 m 11.483 ft [RX2-M5] • Min. sensing object: ø8 mm ø0.315 in Slit on receiver • Sensing range: 4.9 m 16.076 ft [RX-M10] 2.5 m 8.202 ft [RX2-M5] • Min. sensing object: ø6 mm ø0.236 in RF-220 • Sensing range: 0.1 to 3.8 m 0.328 to 12.467 ft [RX-RVM5] 0.1 to 2 m 0.328 to 6.562 ft [RX-PRVM3] 0.1 to 1.3 m 0.328 to 4.265 ft [RX2-PRVM2] • Min. sensing object: ø35 mm ø1.378 in MS-RF21-1 Protective mounting bracket for RF-210 It protects the reflector from damage and maintains alignment. MS-RF22 For RF-220 MS-RF23 For RF-230 RF-T110 This tape can be used in place of the reflector by cutting it to a suitable size. • Size: 100 × 100 mm 3.937 × 3.937 in • Sensing range: 3 m 9.843 ft (at 50 × 50 mm 1.969 × 1.969 in) (There may be a slight variation depending on the product.) PT-RX1000 CHX-SC2 (Note 2) OS-RX-1×5 a b 500 mm 19.685 in 1,000 mm 39.370 in a MICRO PHOTOELECTRIC SENSORS AREA SENSORS Slit mask LIGHT CURTAINS Reflector • RF-210 PRESSURE / FLOW SENSORS • RF-220 33.3 mm 1.311 in INDUCTIVE PROXIMITY SENSORS 11 mm 0.433 in 12.8 mm 0.504 in 8.3 mm 0.327 in 35.3 mm 1.390 in SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Reflector mounting bracket STATIC CONTROL DEVICES • MS-RF21-1 ENDOSCOPE Two M3 (length 12 mm 0.472 in) screws with washers are attached. LASER MARKERS PLC / TERMINALS • MS-RF22 • MS-RF23 HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS Two M3 (length 8 mm 0.315 in) screws with washers are attached. Two M4 (length 10 mm 0.394 in) screws with washers are attached. MACHINE VISION SYSTEMS UV CURING SYSTEMS Protective tube • PT-RX500 • PT-RX1000 Selection Guide Amplifier Built-in Protective tube Cable is protected from external forces. It does not rust as it is made of stainless steel. Power Supply Built-in Amplifierseparated It is useful for beam alignment of thru-beam type sensors. The optimum receiver position is given by indicators, as well as an audio signal. Notes: 1) Refer to CX-400 series pages for dimensions of the reflector or the reflector mounting bracket. 2) Refer to the sensor checker CHX-SC2 pages for details. PARTICULAR USE SENSORS SENSOR OPTIONS 42.3 mm 1.665 in • Sensing range: 2.6 m 8.530 ft [RX-M10] 1.3 m 4.265 ft [RX2-M5] Slit on both sides • Min. sensing object: 3 × 5 mm 0.118 × 0.197 in RF-210 PHOTOELECTRIC SENSORS b *Slit size • Sensing range: 2.8 m 9.186 ft [RX-M10] 1.4 m 4.593 ft [RX2-M5] • Min. sensing object: ø6 mm ø0.236 in • Sensing range: 0.2 to 1.5 m 0.656 to 4.921 ft [RX-RVM5] 0.4 to 1 m 1.312 to 3.281 ft [RX-PRVM3] • Min. sensing object: ø30 mm ø1.181 in PT-RX500 • OS-RX-□ Fitted on the front face of the sensor with one-touch. • Sensing range: 0.8 m 2.625 ft [RX-M10] 0.4 m 1.312 ft [RX2-M5] Slit on both sides • Min. sensing object: 1 × 5 mm 0.039 × 0.197 in Length Slit mask For RX-M10 and RX2-M5 only • Sensing range: 0.4 m 1.312 ft [RX-M10] 0.2 m 0.656 ft [RX2-M5] Slit on both sides • Min. sensing object: 0.5 × 5 mm 0.020 × 0.197 in LASER SENSORS Slit mask CX-400 EX-10 EX-20 Sensor checker EX-30 • CHX-SC2 EX-40 CX-440 EQ-30 PO W ER C LE H VE L X- SC 2 EQ-500 MQ-W Sensor checker RX-LS200 RX RT-610 393 Robust Photoelectric Sensor SPECIFICATIONS FIBER SENSORS LASER SENSORS Standard type Thru-beam PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS Type Item Model No. Sensing range Sensing object INDUCTIVE PROXIMITY SENSORS Hysteresis SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS RX-M50 RX-M2R RX-500G 50 m 164.042 ft 2m 6.562 ft 500 mm 19.685 in Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated DC-12 or DC-13 Switchable either Light-ON or Dark-ON Incorporated NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.5 V or less (at 50 mA sink current) 1 V or less (at 16 mA sink current) ON under unstable sensing condition – 1 ms or less Operation indicator Red LED (lights up when the sensing output is ON) Stability indicator Green LED (lights up under stable light received condition or stable dark condition) – Red LED (lights up during beam emission) Emitting indicator Sensitivity adjuster Continuously variable adjuster – Automatic interference prevention function Incorporated (Two units of sensors can be mounted close together.) Pollution degree 3 (Industrial environmrnt) Protection IP67 (IEC) Ambient temperature –25 to +60 °C –13 to +140 °F (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 3,500 ℓx at the light-receiving face EMC EN 60947-5-2 Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each Emitting element (modulated) Material Infrared LED Red LED Green LED Red LED Infrared LED Red LED 880 nm 0.035 mil 680 nm 0.027 mil 570 nm 0.022 mil 680 nm 0.027 mil 880 nm 0.035 mil 680 nm 0.027 mil Enclosure: Die-cast zinc alloy, Indicator cover: Polyethersulphone, Lens: Polycarbonate (Retroreflective type: Acrylic) Emitter: 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long Receiver: 0.15 mm2 4-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long 0.15 mm2 5-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (thru-beam type: both emitter and receiver). Emitter: 70 g approx. (RX-M50: 75 g approx.) Receiver: 70 g approx. (RX-M50: 75 g approx.) EX-40 RT-610 Opaque, translucent or transparent object (Note 5) NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 2 V or less (at 100 mA sink current) 1 V or less (at 16 mA sink current) Incorporated Net weight RX ø50 mm ø1.969 in or more opaque, or translucent object (Note 2, 5) 40 mA or less Test input (emission halt) function EX-30 RX-LS200 ø50 mm ø1.969 in or more opaque, translucent or specular object (Note 2, 5) Response time Cable extension MQ-W RX-D200R 0.5 mm 0.020 in or less Short-circuit protection EX-20 EQ-30 RX-D700 1 mm 0.039 in or less Output operation Cable EQ-500 RX-RVM5 0.5 mm 0.020 in or less Self-diagnosis output EX-10 CX-440 RX-PRVM3 0.1 to 5 m 700 mm 200 mm 0.1 to 3 m 0.328 to 9.843 ft (Note 2) 0.328 to 16.404 ft (Note 2) 27.559 in (Note 3) 7.874 in (Note 3) Emitter: 20 mA or less (RX-M50: 25 mA or less), Receiver: 25 mA or less Peak emission wavelength CX-400 Red 15 % or less of operation distance (Note 3) Output operation Environmental resistance UV CURING SYSTEMS Infrared – LASER MARKERS MACHINE VISION SYSTEMS Infrared (Long sensing range) – Sensing output PLC / TERMINALS Diffuse reflective Red (with polarizing filters) 12 to 24 V DC ±10 %   Ripple P-P 10 % or less Current consumption Short-circuit protection FA COMPONENTS Green 10 m 32.808 ft Supply voltage STATIC CONTROL DEVICES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Red RX-M10 Repeatability (perpendicular to sensing axis) Utilization category HUMAN MACHINE INTERFACES Retroreflective ø10 mm 0.394 in or more opaque object (Note 4) MEASUREMENT SENSORS ENDOSCOPE Infrared Long sensing range PRESSURE / FLOW SENSORS PARTICULAR USE SENSORS RX SERIES 75 g approx. MS-RX-1 (Sensor mounting bracket): 1 set MS-RX-1 (Sensor mounting bracket): 1 set for emitter and receiver RF-230 (Reflector): 1 pc. Adjusting screwdriver: 1 pc. Adjusting screwdriver: 1 pc. Accessories Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range of RX-PRVM3 and RX-RVM5 is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Reflector cannot be placed in this range Sensor Actual sensing range of the sensor 0.1 m 0.328 ft Setting range of the reflector ( RX-PRVM3: 3 m 9.843 ft ) Reflector Reflector 5 m 16.404 ft MS-RX-1 (Sensor mounting bracket): 1 set Adjusting screwdriver: 1 pc. 3) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object. 4) If slit masks (optional) are fitted on RX-M10, an object of 0.5 × 5 mm 0.020 × 0.197 in can be detected. 5) Make sure to confirm detection with an actual sensor before use. Robust Photoelectric Sensor RX SERIES SPECIFICATIONS 394 FIBER SENSORS LASER SENSORS DC 2-wire type Type PHOTOELECTRIC SENSORS Thru-beam Retroreflective (with polarizing filters) Diffuse reflective RX2-M5 RX2-PRVM2 RX2-D300 Sensing range 5 m 16.404 ft 0.1 to 2 m 0.328 to 6.562 ft (Note 2) 300 mm 11.811 in (Note 3) Sensing object ø10 mm ø0.394 in or more opaque object (Note 4) ø50 mm ø1.969 in or more opaque, translucent or specular object (Note 2, 5) Opaque, translucent or transparent object (Note 5) AREA SENSORS – – 15 % or less of operation distance (Note 3) LIGHT CURTAINS 0.5 mm 0.020 in or less 1 mm 0.039 in or less 0.5 mm 0.020 in or less PRESSURE / FLOW SENSORS Item Model No. Hysteresis Repeatability (perpendicular to sensing axis) Supply voltage 12 to 24 V DC ±10 %   Ripple P-P 10 % or less Current consumption Emitter: 8 mA or less, Receiver: 0.8 mA or less (Note 6) Output operation PARTICULAR USE SENSORS SENSOR OPTIONS Switchable either Light-ON or Dark-ON Short-circuit protection SIMPLE WIRE-SAVING UNITS Incorporated Response time 3 ms or less Operation indicator WIRE-SAVING SYSTEMS Red LED (lights up when the output is ON) Light-ON mode: lights up under stable light received condition Green LED Dark-ON mode: lights up under stable dark condition Stability indicator Emitting indicator – Red LED (lights up during beam emission) Sensitivity adjuster Continuously variable adjuster Protection Environmental resistance INDUCTIVE PROXIMITY SENSORS 1 mA or less (Note 6) Non contact DC 2-wire type • Load current: 5 to 100 mA • Residual voltage: 4 V or less (Note 7) Sensing output MICRO PHOTOELECTRIC SENSORS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE IP67 (IEC) Ambient temperature –20 to +60 °C –4 to +140 °F (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance PLC / TERMINALS Incandescent light: 3,500 ℓx at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each Shock resistance Emitting element Peak emission wavelength Material LASER MARKERS Infrared LED (modulated) Red LED (modulated) Infrared LED (modulated) 880 nm 0.035 mil 680 nm 0.027 mil 890 nm 0.035 mil Enclosure: Die-cast zinc alloy, Indicator cover: Polyethersulphone, Lens: Polycarbonate (RX2-PRVM2: Acrylic) HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 0.15 mm2 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long Cable – (Note 7) Cable extension Net weight Emitter: 70 g approx., Receiver: 70 g approx. Accessories MS-RX-1 (Sensor mounting bracket): MS-RX-1 (Sensor mounting bracket): 1 set MS-RX-1 (Sensor mounting bracket): 1 set 1 set for emitter and receiver RF-230 (Reflector): 1 pc. Adjusting screwdriver: 1 pc. Adjusting screwdriver: 1 pc. Adjusting screwdriver: 1 pc. 75 g approx. 70 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) The sensing range and the sensing object for RX2-PRVM2 are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Reflector cannot be placed in this range Sensor Actual sensing range of the sensor 0.1 m 0.328 ft Setting range of the reflector Reflector 2m 6.562 ft Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated CX-400 EX-10 EX-20 Reflector 3) The sensing range and the hysteresis of RX2-D300 are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object. 4) If slit masks (optional) are fitted, an object of 0.5 × 5 mm 0.020 × 0.197 in can be detected. 5) Make sure to confirm detection with an actual sensor before use. 6) It is the leakage current when the output is in the OFF state. 7) When extending the cable, the residual voltage will be increased depending on the type of cable used. Verify the residual voltage when extending the cable. EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 395 Robust Photoelectric Sensor SPECIFICATIONS FIBER SENSORS LASER SENSORS Heavy duty type PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS RX SERIES Type Item Model No. Thru-beam Cable length 2 m 6.562 ft Cable length 3 m 9.843 ft Cable length 5 m 16.404 ft RX4-M5 RX4-M5-C3 RX4-M5-C5 Sensing range 5 m 16.404 ft Sensing object ø10 mm ø0.394 in or more opaque object Repeatability (perpendicular to sensing axis) 0.5 mm 0.020 in or less Supply voltage 12 to 24 V DC ±10 %   Ripple P-P 10 % or less Current consumption Emitter: 20 mA or less, Receiver: 25 mA or less NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 2 V or less (at 100 mA sink current) 1 V or less (at 16 mA sink current) Sensing output SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Output operation Short-circuit protection WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Self-diagnosis output STATIC CONTROL DEVICES HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated EX-10 EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 ON under unstable sensing condition – Short-circuit protection 1 ms or less Test input (emission halt) function Incorporated Operation indicator Red LED (lights up when the sensing output is ON) Stability indicator Green LED (lights up under stable light received condition or stable dark condition) Emitting indicator Red LED (lights up during beam emission) Sensitivity adjuster Continuously variable adjuster Protection Ambient temperature IP67 (IEC), IP67g (JEM) –25 to +60 °C –13 to +140 °F (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Voltage withstandability Incandescent light: 3,500 ℓx at the light-receiving face 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each Emitting element Material Cable CX-400 NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.5 V or less (at 50 mA sink current) 1 V or less (at 16 mA sink current) Response time Environmental resistance PLC / TERMINALS Incorporated Output operation ENDOSCOPE LASER MARKERS Switchable either Light-ON or Dark-ON Protective tube length Cable extension Net weight Accessories Infrared LED (Peak emission wavelength: 880 nm 0.035 mil, modulated) Enclosure: Die-cast zinc alloy (Fluorine resin coating), Indicator cover: Polyethersulphone, Lens: Polyalylate, Protective tube sheath: Oil resistant PVC 0.15 mm2 4-core (emitter: 3-core) oil, heat and cold resistant cabtyre cable 1 m 3.281 ft 2 m 6.562 ft 4 m 13.123 ft Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. Emitter: 175 g approx., Receiver: 175 g approx. Emitter: 265 g approx., Receiver: 265 g approx. Emitter: 495 g approx., Receiver: 495 g approx. MS-RX-2 (Sensor mounting bracket): 1 set for emitter and receiver, Adjusting screwdriver: 1 pc. Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. Robust Photoelectric Sensor RX SERIES I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS LASER SENSORS RX-□  RX4-□ I/O circuit diagrams PHOTOELECTRIC SENSORS Wiring diagram Emitter of thru-beam type sensor Emitter of thru-beam type sensor MICRO PHOTOELECTRIC SENSORS Color code D Sensor circuit 396 (Brown) +V (Pink) Test input 1 mA max. (emission halt input) *1 + – 12 to 24 V DC ±10 % Pink LIGHT CURTAINS *1 + – (Blue) 0 V Internal circuit AREA SENSORS Brown 12 to 24 V DC ±10 % INDUCTIVE PROXIMITY SENSORS Blue * 1 Users’ circuit PARTICULAR USE SENSORS Non-voltage contact or NPN open-collector transistor Symbol … D: Reverse supply polarity protection diode PRESSURE / FLOW SENSORS SENSOR OPTIONS or SIMPLE WIRE-SAVING UNITS • Test input (emission halt input) [Supply voltage – 2.5 V] or more: Emission [Supply voltage – 3.3 V] or less: Emission halt WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Receiver of thru-beam type sensor Color code D Load Sensor circuit (Black) Sensing output Tr2 ZD1 ENDOSCOPE Brown (Brown) +V Load Tr1 STATIC CONTROL DEVICES Receiver of thru-beam type sensor 100mA max. Black Load (Orange) Self-diagnosis output (Note) + – LASER MARKERS Load + 12 to 24 V DC ±10 % – Orange 12 to 24 V DC ±10 % HUMAN MACHINE INTERFACES 50 mA max. ZD2 Internal circuit ENERGY CONSUMPTION VISUALIZATION COMPONENTS Blue (Blue) 0 V FA COMPONENTS Users’ circuit Note: The self-diagnosis output does not incorporate a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. MACHINE VISION SYSTEMS UV CURING SYSTEMS Symbols ... D: Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : NPN output transistor Retroreflective and diffuse reflective type sensors Sensor circuit *1 Black Tr2 ZD2 Internal circuit ZD1 Power Supply Built-in Load + 100 mA max. – Load 50 mA max. Pink (Blue) 0 V Users’ circuit Symbols ... D: Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : NPN output transistor 12 to 24 V DC ±10 % CX-400 EX-10 Blue (Orange) Self-diagnosis output (Note) + – Orange 12 to 24 V DC ±10 % Note: The self-diagnosis output does not incorporate a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. Amplifierseparated Load Load (Black) Sensing output Tr1 Amplifier Built-in Brown (Brown) +V (Pink) Test input 1mA max. (emission halt input) Selection Guide Retroreflective and diffuse reflective type sensors Color code D PLC / TERMINALS EX-20 *1 EX-30 EX-40 * 1 CX-440 Non-voltage contact or NPN open-collector transistor EQ-30 EQ-500 or MQ-W RX-LS200 • Test input (emission halt input) [Supply voltage – 2.5 V] or more: Emission [Supply voltage – 3.3 V] or less: Emission halt RX RT-610 397 Robust Photoelectric Sensor I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS RX2-□ I/O circuit diagrams (Brown) +V Sensor circuit PRESSURE / FLOW SENSORS + – + – 12 to 24 V DC ±10 % Blue Internal circuit PARTICULAR USE SENSORS Users’ circuit Symbol … D: Reverse supply polarity protection diode Receiver of thru-beam type sensor, retroreflective and diffuse reflective type sensors Receiver of thru-beam type sensor, retroreflective and diffuse reflective type sensors Color code Bleeder resistance WIRE-SAVING SYSTEMS (Brown) Output Sensor circuit STATIC CONTROL DEVICES Brown 12 to 24 V DC ±10 % (Blue) 0 V INDUCTIVE PROXIMITY SENSORS MEASUREMENT SENSORS Emitter of thru-beam type sensor Color code D LIGHT CURTAINS SIMPLE WIRE-SAVING UNITS Wiring diagrams Emitter of thru-beam type sensor AREA SENSORS SENSOR OPTIONS RX SERIES Tr ZD ENDOSCOPE Internal circuit LASER MARKERS Load Brown 5 to 100 mA in the ON state + 4 V in the 1 mA in the OFF state ON state – Receiver of thru-beam type sensor: 0.8 mA (Blue) 0 V ( ) 12 to 24 V DC ±10 % Load + – 12 to 24 V DC ±10 % Blue Users’ circuit Symbols ... D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : PNP output transistor PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Conditions for the load 1) T  he load should not be actuated by the leakage current (1 mA; 0.8 mA for receiver of thru-beam type sensor) in the OFF state. 2) T  he load should be actuated by (supply voltage – 4 V) in the ON state. 3) The current in the ON state should be between 5 to 100 mA DC. In case the current is less than 5 mA, connect a bleeder resistance in parallel to the load (shown in dotted line above) so that a current of 5 mA, or more, flows. FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS SENSING CHARACTERISTICS (TYPICAL) Amplifierseparated RX-□ Correlation between setting distance and excess gain 100 100 100 50 50 50 EX-20 EX-30 EX-40 Excess gain CX-400 EX-10 RX-M50 10 5 EQ-500 MQ-W RX-LS200 RX RT-610 RX-RVM5 10 RX-PRVM3 5 1 0 20 60 80 100 40 65.617 131.234 196.850 262.467 328.084 Setting distance L (m ft) RX-D700 10 RX-500G 5 RX-D300 RX-M2R RX-M10 CX-440 EQ-30 All models Excess gain Amplifier Built-in Power Supply Built-in Excess gain Selection Guide 1 0 2 6 8 10 4 6.562 13.123 19.685 26.247 32.808 Setting distance L (m ft) RX-D200R 1 0 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Setting distance L (mm in) Robust Photoelectric Sensor 398 RX SERIES SENSING CHARACTERISTICS (TYPICAL) FIBER SENSORS RX-M10 Thru-beam type Parallel deviation with slit masks (1 × 5 mm 0.039 × 0.197 in) Emitter 5 16.404 ℓ Receiver 200 0 200 400 7.874 7.874 15.748 Left Center Right Operating point ℓ (mm in) RX-M50 3 9.843 2 Slit on 6.562 emitter 0 200 7.874 Parallel deviation ℓ L Receiver 100 0 100 200 3.937 3.937 7.874 Left Center Right Operating point ℓ (mm in) RX-M2R Thru-beam type Emitter Slit on 1 receiver 3.281 Slit on both sides Parallel deviation Emitter 1 3.281 L ℓ Receiver 100 0 100 200 3.937 3.937 7.874 Left Center Right Operating point ℓ (mm in) Thru-beam type Parallel deviation Slit on 4 receiver Emitter 13.123 Slit on both side 2 ℓ L 6.562 Slit on emitter Receiver 0 400 200 0 200 400 15.748 7.874 7.874 15.748 Left Center Right Operating point ℓ (mm in) RX4-M5□ 40 131.234 Emitter 20 65.617 ℓ L Receiver Emitter 1 3.281 ℓ L 400 15.748 Receiver 100 0 100 200 3.937 3.937 7.874 Left Center Right Operating point ℓ (mm in) Emitter 0 40 1.575 L ℓ 200 7.874 Receiver 6 19.685 4 13.123 2 6.562 ℓ Receiver 200 200 400 0 7.874 7.874 15.748 Left Center Right Operating point ℓ (mm in) Parallel deviation 4 13.123 Emitter Slit on receiver ℓ Slit on both sides 0 100 3.937 L Receiver 1 3.281 Emitter 0.5 Slit on 1.640 both sides 0 100 3.937 50 0 50 100 1.969 1.969 3.937 Left Center Right Operating point ℓ (mm in) Slit on receiver L ℓ Receiver 50 0 50 100 1.969 1.969 3.937 Left Center Right Operating point ℓ (mm in) RX-RVM5 Retroreflective type RX2-PRVM2 Retroreflective type Parallel deviation Parallel deviation LASER MARKERS Receiver L Sensor 50 0 50 100 1.969 1.969 3.937 Left Center Right Operating point ℓ (mm in) 2 6.562 0 100 3.937 Reflector (RF-230) ℓ L Sensor 50 0 50 100 1.969 1.969 3.937 Left Center Right Operating point ℓ (mm in) Setting distance L (m ft) ℓ 4 13.123 Slit on emitter ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Emitter Slit on receiver Slit on both sides 0 200 7.874 ℓ L Receiver Selection Guide Amplifier Built-in Power Supply Built-in 100 0 100 200 Amplifierseparated 3.937 3.937 7.874 Left Center Right Operating point ℓ (mm in) CX-400 EX-10 EX-20 EX-40 6 19.685 Reflector (RF-230) 1 3.281 PLC / TERMINALS 200 0 200 400 7.874 7.874 15.748 HUMAN Left Center Right MACHINE Operating point ℓ (mm in) INTERFACES 3 9.843 2 6.562 SIMPLE WIRE-SAVING UNITS EX-30 8 26.247 3 9.843 0 100 3.937 0.5 1.640 L RX-PRVM3 Retroreflective type 1 3.281 1 3.281 Emitter 2 6.562 Slit on emitter 1.5 4.921 SENSOR OPTIONS L ℓ 4 13.123 Slit on emitter PARTICULAR USE SENSORS ENDOSCOPE Parallel deviation with slit masks (3 × 5 mm 0.118 × 0.197 in) Setting distance L (m ft) 1.5 4.921 4 13.123 2 6.562 2 6.562 Setting distance L (m ft) 6 19.685 0 400 15.748 Setting distance L (m ft) Setting distance L (m ft) 2 6.562 Setting distance L (m ft) Setting distance L (m ft) 8 26.247 Parallel deviation with slit masks (1 × 5 mm 0.039 × 0.197 in) INDUCTIVE PROXIMITY SENSORS Emitter Thru-beam type Parallel deviation with slit masks (0.5 × 5 mm 0.020 × 0.197 in) PRESSURE / FLOW SENSORS STATIC CONTROL DEVICES RX2-M5 Parallel deviation LIGHT CURTAINS MEASUREMENT SENSORS 0 400 15.748 20 0 20 40 0.787 0.787 1.575 Left Center Right Operating point ℓ (mm in) MICRO PHOTOELECTRIC SENSORS WIRE-SAVING SYSTEMS 8 26.247 600 23.622 0 200 7.874 500 0 500 1,000 19.685 19.685 39.370 Left Center Right Operating point ℓ (mm in) Setting distance L (m ft) 60 196.850 2 6.562 Thru-beam type Parallel deviation 800 31.496 Setting distance L (m ft) Setting distance L (m ft) 2 6.562 Slit on both sides PHOTOELECTRIC SENSORS AREA SENSORS 6 19.685 Slit on receiver RX-500G 80 262.467 0 1,000 39.370 Slit on emitter 3 9.843 0 200 7.874 Thru-beam type 8 26.247 Setting distance L (m ft) 0 400 15.748 L 4 13.123 Setting distance L (m ft) 10 32.808 Setting distance L (m ft) Setting distance L (m ft) 4 13.123 Parallel deviation with slit masks (3 × 5 mm 0.118 × 0.197 in) Setting distance L (m ft) Parallel deviation with slit masks (0.5 × 5 mm 0.020 × 0.197 in) Parallel deviation LASER SENSORS CX-440 2 6.562 EQ-30 EQ-500 1 3.281 Reflector (RF-230) ℓ L MQ-W RX-LS200 RX 0 100 3.937 Sensor 50 0 50 100 1.969 1.969 3.937 Left Center Right Operating point ℓ (mm in) RT-610 399 Robust Photoelectric Sensor SENSING CHARACTERISTICS (TYPICAL) FIBER SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS RX-D700 Sensing field 800 31.496 SIMPLE WIRE-SAVING UNITS Correlation between sensing object size and sensing range 200 × 200 mm 7.874 × 7.874 in White nonglossy paper 600 23.622 ℓ L 400 15.748 Sensor 200 7.874 0 20 0.787 PARTICULAR USE SENSORS SENSOR OPTIONS Diffuse reflective type 800 31.496 As the sensing object size becomes smaller than the standard size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the sensing range shortens, as shown in the left graph. 600 23.622 Sensing range L (mm in) PHOTOELECTRIC SENSORS Setting distance L (mm in) LASER SENSORS RX SERIES 400 15.748 a × a mm a × a in White nonglossy paper 200 7.874 L 10 0 10 20 0.394 0.394 0.787 Left Center Right Operating point ℓ (mm in) 0 Sensor 50 100 150 200 1.969 3.937 5.906 7.874 White non-glossy paper side length a (mm in) RX-D200R Diffuse reflective type Sensing field Correlation between sensing object size and sensing range WIRE-SAVING SYSTEMS LASER MARKERS 100 3.937 20 0.787 FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated As the sensing object size becomes smaller than the standard size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the sensing range shortens, as shown in the left graph. For plotting the left graph, the sensitivity has been set such that a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just detectable at a distance of 200 mm 7.874 in. L Sensor 0 10 0 10 20 0.394 0.394 0.787 Left Center Right Operating point ℓ (mm in) 50 100 150 1.969 3.937 5.906 White non-glossy paper side length a (mm in) 200 7.874 RX2-D300 Diffuse reflective type Sensing field Correlation between sensing object size and sensing range 400 15.748 Setting distance L (mm in) ENERGY CONSUMPTION VISUALIZATION COMPONENTS L 100 3.937 a × a mm a × a in White nonglossy paper Sensor 0 PLC / TERMINALS HUMAN MACHINE INTERFACES ℓ Sensing range L (mm in) ENDOSCOPE 200 × 200 mm 7.874 × 7.874 in White nonglossy paper 400 15.748 300 11.811 300 11.811 200 7.874 200 × 200 mm 7.874 × 7.874 in White nonglossy paper 100 3.937 ℓ 0 20 0.787 L Sensor 10 0 10 20 0.394 0.394 0.787 Left Center Right Operating point ℓ (mm in) Sensing range L (mm in) STATIC CONTROL DEVICES 200 7.874 200 7.874 Setting distance L (mm in) MEASUREMENT SENSORS For plotting the left graph, the sensitivity has been set such that a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just detectable at a distance of 700 mm 27.559 in. 200 7.874 a × a mm a × a in White nonglossy paper 100 3.937 0 As the sensing object size becomes smaller than the standard size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the sensing range shortens, as shown in the left graph. For plotting the left graph, the sensitivity has been set such that a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just detectable at a distance of 300 mm 11.811 in. L Sensor 50 100 150 200 1.969 3.937 5.906 7.874 White non-glossy paper side length a (mm in) PRECAUTIONS FOR PROPER USE Refer to General precautions. CX-400 EX-10 • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. EX-20 EX-30 EX-40 CX-440 EQ-30 EQ-500 MQ-W RX-LS200 RX RT-610 Wiring • The self-diagnosis output does not incorporate a shortcircuit protection circuit. Do not connect it directly to a power supply or a capacitive load. Mounting • The tightening torque should be 1.17 N·m or less. M4 (length 16 mm 0.630 in) hexagon-socket-head bolt Attached mounting bracket Others • Do not use during the initial transient time (50 ms) after the power supply is switched on. Robust Photoelectric Sensor PRECAUTIONS FOR PROPER USE RX SERIES 400 Refer to General precautions. • Do not connect sensors in series (AND circuit). RX-RVM5 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS Glossy object sensing • Please take care of the following points when detecting materials having a gloss. 1 Make L, shown in the diagram, sufficiently long. 2 Install at an angle of 10 to 30 degrees to the sensing object. MICRO PHOTOELECTRIC SENSORS Load AREA SENSORS + – Reflector Glossy surface LIGHT CURTAINS DC power supply PRESSURE / FLOW SENSORS Sensing object INDUCTIVE PROXIMITY SENSORS 10 to 30° • The residual voltage of the sensor is 4 V. Before connecting to a relay, be aware of the actuation voltage of the relay. (Not all 12 V relays may be connected as the load.) PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS L Relay Sensor Make L sufficiently long RX-PRVM3  RX2-PRVM2 Example of sensing objects • Can wrapped by clear film • Aluminum sheet covered by plastic film • Gold or silver color (specular) label or wrapping paper + – 12 V DC VS = 4 V Residual voltage when the sensing output is ON. Retroreflective type sensor with polarizing filters • If a shiny object is covered or wrapped with a transparent film such as those described below, the retroreflective type sensor with polarizing filters may not be able to detect it. In that case, follow the steps given below. VR (Relay actuation voltage) Relay actuation voltage: VR ≤ 12 – 4 V ≤ 8V • Tilt the sensor with respect to the sensing object while fitting. • Reduce the sensitivity. • Increase the distance between the sensor and the sensing object. MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE RX4-□ Connection of protective tube connector • Connect the junction connector securely as shown below. The tightening torque should be 0.98 N·m or less. When mounted on a plate 7 mm 0.276 in or less ø14.5 mm ø0.571 in hole Steps WIRE-SAVING SYSTEMS Oil resistant protective tube Oil resistant cable LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS M14 nut (Accessory) Junction connector UV CURING SYSTEMS When mounted with a female screw RX2-□ M14 × 1 mm 0.039 in tapped hole Wiring • Always connect the sensor to the power supply through a load. If the sensor is connected to the power supply directly, the short-circuit protection makes the sensor inoperable. (The output stays in the OFF state and no indicator lights up.) If this happens, connect the sensor to the power supply through a load. Further, note that the sensor will be damaged if the power supply is connected in reverse without a load. Effective thread length 11 mm 0.433 in or more Oil resistant protective tube Selection Guide Amplifier Built-in Power Supply Built-in Amplifierseparated Junction connector CX-400 When connected to another protective tube EX-10 EX-20 Oil resistant protective tube EX-30 EX-40 Brown lead wire + – DC power supply Junction connector Brown lead wire – + DC power supply Can be connected to a straight combination connector (RCC-F1060-M14) manufactured by NIPPON FLEX CO., LTD. CX-440 EQ-30 EQ-500 MQ-W RX-LS200 Blue lead wire Blue lead wire RX RT-610 401 FIBER SENSORS LASER SENSORS Robust Photoelectric Sensor RX SERIES RX-M10  RX-M2R  RX-500G  RX2-M5 PHOTOELECTRIC SENSORS Sensitivity adjuster (Note 1) Operation mode switch (Note 1) MICRO PHOTOELECTRIC SENSORS PRESSURE / FLOW SENSORS 14 0.551 35 1.378 (2.5) (0.098) 3 0.118 STATIC CONTROL DEVICES ENDOSCOPE HUMAN MACHINE INTERFACES 35 1.378 14 3.6 0.142 0.551 (2.5) (0.098) 3 0.118 2-M4 × 0.7 0.028 thru-hole threads 14 0.551 ø9 ø0.354 oil resistant protective tube, 2 m 6.562 ft long (Note 3) 14 0.551 (Oil resistant PVC) ø3.7 ø0.146 cable ø14 15 10 ø0.551 0.591 0.394 20.9 0.823 Junction connector (Brass) Waterproof packing M14 × 1 0.039 RX-D700  RX-D200R  RX2-D300 Sensitivity adjuster Operation mode switch Sensor Stability indicator (Green) EX-10 RX-LS200 RX RT-610 Operation indicator (Red) Indicator cover EX-20 (2.5) (0.098) 35 1.378 3 0.118 2-M4 × 0.7 0.028 thru-hole threads Center of sensing 15.5 0.610 14 0.551 35 1.378 14 3.6 0.142 0.551 ø3.7 ø0.146 cable, 2 m 6.562 ft long M8 × 0.75 0.030 Operation indicator (Red) 39 1.535 3 0.118 2-M4 × 0.7 0.028 thru-hole threads Center of sensing 14 0.551 35 1.378 15.5 0.610 14 3.6 0.142 0.551 ø3.7 ø0.146 cable, 2 m 6.562 ft long M8 × 0.75 0.030 Cover-fixing screw EQ-30 (2.5) (0.098) 14 0.551 Notes: 1) Not incorporated on the emitter. 2) It is the emitting indicator (red) on the emitter. 3) The given length of the protective tube is for RX4-M5-C3. (RX4-M5: 1 m 3.281 ft, RX4-M5-C5: 4 m 13.123 ft) EX-40 Stability indicator (Green) Indicator cover (NBR) 14 0.551 Sensor Cover-fixing screw CX-400 MQ-W 14 3.6 0.142 0.551 Operation indicator (Red) (Note 1) 35 1.378 (16.5) (0.650) Connector on the sensor (Brass · Black chromate) Amplifierseparated EQ-500 14 0.551 35 1.378 RX-PRVM3  RX-RVM5  RX2-PRVM2 Cover-fixing screw 35 20 1.378 0.787 Power Supply Built-in 2-M4 × 0.7 0.028 thru-hole threads Sensitivity adjuster Operation mode indicator Selection Guide CX-440 3 0.118 ø3.7 ø0.146 cable, 2 m 6.562 ft long M8 × 0.75 0.030 Stability indicator (Green) (Note 2) Indicator cover MACHINE VISION SYSTEMS EX-30 43 1.693 (2.5) (0.098) Notes: 1) Not incorporated on the emitter. 2) It is the emitting indicator (red) on the emitter. Sensor Sensitivity adjuster (Note 1) Operation mode switch (Note 1) FA COMPONENTS Amplifier Built-in 14 0.551 20 0.787 RX4-M5□ Beam axis Operation indicator (Red) (Note 1) Indicator cover 14 0.551 Notes: 1) Not incorporated on the emitter. 2) It is the emitting indicator (red) on the emitter. 14 0.551 Stability indicator (Green) (Note 2) Cover-fixing screw ø3.7 ø0.146 cable, 2 m 6.562 ft long M8 × 0.75 0.030 ENERGY CONSUMPTION VISUALIZATION COMPONENTS UV CURING SYSTEMS Sensitivity adjuster (Note 1) Operation mode switch (Note 1) Beam axis 20 0.787 LASER MARKERS PLC / TERMINALS 2-M4 × 0.7 0.028 thru-hole threads Beam axis SENSOR OPTIONS MEASUREMENT SENSORS Sensor Operation indicator (Red) (Note 1) Indicator cover PARTICULAR USE SENSORS WIRE-SAVING SYSTEMS RX-M50 Cover-fixing screw INDUCTIVE PROXIMITY SENSORS SIMPLE WIRE-SAVING UNITS Sensor Stability indicator (Green) (Note 2) AREA SENSORS LIGHT CURTAINS The CAD data in the dimensions can be downloaded from our website. Refer to CX-400 series pages for dimensions of the reflector or the reflector mounting bracket. DIMENSIONS (Unit: mm in) Robust Photoelectric Sensor DIMENSIONS (Unit: mm in) 402 RX SERIES The CAD data in the dimensions can be downloaded from our website. Refer to CX-400 series pages for dimensions of the reflector or the reflector mounting bracket. MS-RX-1 Sensor mounting bracket (Accessory for RX-□, RX2-□) Mounting drawing with RX-D700 10 0.394 8.5 0.335 4.4 0.173 10 0.394 37 1.457 13.5 13.5 0.531 0.531 5 15° 2 0.197 0.079 (2.5) (0.098) 4.4 0.173 10 0.394 37 1.457 35 1.378 8.5 0.335 4.4 0.173 6 0.236 INDUCTIVE PROXIMITY SENSORS 45 1.772 38 1.496 PARTICULAR USE SENSORS 45 1.772 25.5 1.004 t2 t 0.079 15° SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS 16 0.630 23 0.906 30 1.181 Material: Cold rolled carbon steel (SPCC) Two M4 (length 16 mm 0.630 in) hexagon-socket-head bolts are attached. MS-RX-2 WIRE-SAVING SYSTEMS Sensor mounting bracket (Accessory for RX4-□) Assembly dimensions 8 16 0.315 0.630 Mounting drawing with RX4-M5 10 0.394 8.5 0.335 4.4 0.173 10 0.394 37 1.457 13.5 13.5 0.531 0.531 5 15° 2 0.197 0.079 57 2.244 50 1.969 10 0.394 16 0.630 8 0.315 4.4 0.173 4.4 0.173 8.5 0.335 14 0.551 4.4 0.173 35 1.378 R14 R0.551 42 1.654 t2 t 0.079 15° 36 1.417 37 1.457 35 1.378 4.4 10 0.173 0.394 (2.5) (0.098) Beam axis 5 0.197 3 0.118 LIGHT CURTAINS PRESSURE / FLOW SENSORS R14 R0.551 24 0.945 MICRO PHOTOELECTRIC SENSORS AREA SENSORS 8 0.315 14 0.551 5 0.197 3 0.118 4.4 17 0.173 0.669 4.4 0.173 LASER SENSORS PHOTOELECTRIC SENSORS Assembly dimensions 8 16 0.315 0.630 FIBER SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS 57 2.244 FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 17 0.669 30 1.181 t2 t 0.079 MEASUREMENT SENSORS Selection Guide Material: Cold rolled carbon steel (SPCC) Two M4 (length 16 mm 0.630 in) hexagon-socket-head bolts are attached. Amplifier Built-in Power Supply Built-in PT-RX500  PT-RX1000 Protective tube (Optional) L 9 0.354 15 0.591 ø18 ø0.709 ø5 ø0.197 Amplifierseparated CX-400 EX-10 EX-20 EX-30 ø10 ø0.394 (Brass) ø7 ø0.276 spiral tube [Stainless steel (SUS304)] Internal thread M8 × 0.75 0.030, 4 0.157 deep • Length L Model No. PT-RX500 PT-RX1000 14 0.551 M10 × 1 0.039 thread [Brass (C3604) (Nickel plated)] EX-40 CX-440 EQ-30 EQ-500 MQ-W Length L RX-LS200 500 + 100 19.685 + 00.394 RX 1,000 + 100 39.370 + 00.394 RT-610
RX-500G 价格&库存

很抱歉,暂时无法提供与“RX-500G”相匹配的价格&库存,您可以联系我们找货

免费人工找货