0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
S1DX-A4C60S-DC24V

S1DX-A4C60S-DC24V

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    S1DX-A4C60S-DC24V

  • 数据手册
  • 价格&库存
S1DX-A4C60S-DC24V 数据手册
S1DX Timers COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES S1DX RoHS compliance Features • Large dial for improved visibility and operability • Four operation modes (Power ON-delay, Power flicker, Power one-shot, Power one-cycle) • LED display for easy operation check. • Mounting frame available for easy panel installation. Product types  Plug-in terminal 1) Power ON-delay AC operating type Time range Time-out 2 Form C type Time-out 4 Form C type 0.05 to 0.5 s 0.1 to 1 s 0.1 to 3 s 0.2 to 5 s 0.5 to 10 s 1 to 30 s 3 to 60 s 0.1 to 3 min 0.5 to 10 min 1 to 30 min 3 to 60 min 0.1 to 3 h 0.05 to 0.5 s 0.1 to 1 s 0.1 to 3 s 0.2 to 5 s 0.5 to 10 s 1 to 30 s 3 to 60 s 0.1 to 3 min 0.5 to 10 min 1 to 30 min 3 to 60 min 0.1 to 3 h 24V AC Part No. S1DX-A2C0.5S-AC24V S1DX-A2C1S-AC24V S1DX-A2C3S-AC24V S1DX-A2C5S-AC24V S1DX-A2C10S-AC24V S1DX-A2C30S-AC24V S1DX-A2C60S-AC24V S1DX-A2C3M-AC24V S1DX-A2C10M-AC24V S1DX-A2C30M-AC24V S1DX-A2C60M-AC24V S1DX-A2C3H-AC24V S1DX-A4C0.5S-AC24V S1DX-A4C1S-AC24V S1DX-A4C3S-AC24V S1DX-A4C5S-AC24V S1DX-A4C10S-AC24V S1DX-A4C30S-AC24V S1DX-A4C60S-AC24V S1DX-A4C3M-AC24V S1DX-A4C10M-AC24V S1DX-A4C30M-AC24V S1DX-A4C60M-AC24V S1DX-A4C3H-AC24V 100 to 120V AC Part No. S1DX-A2C0.5S-AC120V S1DX-A2C1S-AC120V S1DX-A2C3S-AC120V S1DX-A2C5S-AC120V S1DX-A2C10S-AC120V S1DX-A2C30S-AC120V S1DX-A2C60S-AC120V S1DX-A2C3M-AC120V S1DX-A2C10M-AC120V S1DX-A2C30M-AC120V S1DX-A2C60M-AC120V S1DX-A2C3H-AC120V S1DX-A4C0.5S-AC120V S1DX-A4C1S-AC120V S1DX-A4C3S-AC120V S1DX-A4C5S-AC120V S1DX-A4C10S-AC120V S1DX-A4C30S-AC120V S1DX-A4C60S-AC120V S1DX-A4C3M-AC120V S1DX-A4C10M-AC120V S1DX-A4C30M-AC120V S1DX-A4C60M-AC120V S1DX-A4C3H-AC120V 200 to 220V AC Part No. S1DX-A2C0.5S-AC220V S1DX-A2C1S-AC220V S1DX-A2C3S-AC220V S1DX-A2C5S-AC220V S1DX-A2C10S-AC220V S1DX-A2C30S-AC220V S1DX-A2C60S-AC220V S1DX-A2C3M-AC220V S1DX-A2C10M-AC220V S1DX-A2C30M-AC220V S1DX-A2C60M-AC220V S1DX-A2C3H-AC220V S1DX-A4C0.5S-AC220V S1DX-A4C1S-AC220V S1DX-A4C3S-AC220V S1DX-A4C5S-AC220V S1DX-A4C10S-AC220V S1DX-A4C30S-AC220V S1DX-A4C60S-AC220V S1DX-A4C3M-AC220V S1DX-A4C10M-AC220V S1DX-A4C30M-AC220V S1DX-A4C60M-AC220V S1DX-A4C3H-AC220V 220 to 240V AC Part No. S1DX-A2C0.5S-AC240V S1DX-A2C1S-AC240V S1DX-A2C3S-AC240V S1DX-A2C5S-AC240V S1DX-A2C10S-AC240V S1DX-A2C30S-AC240V S1DX-A2C60S-AC240V S1DX-A2C3M-AC240V S1DX-A2C10M-AC240V S1DX-A2C30M-AC240V S1DX-A2C60M-AC240V S1DX-A2C3H-AC240V S1DX-A4C0.5S-AC240V S1DX-A4C1S-AC240V S1DX-A4C3S-AC240V S1DX-A4C5S-AC240V S1DX-A4C10S-AC240V S1DX-A4C30S-AC240V S1DX-A4C60S-AC240V S1DX-A4C3M-AC240V S1DX-A4C10M-AC240V S1DX-A4C30M-AC240V S1DX-A4C60M-AC240V S1DX-A4C3H-AC240V Notes: 1. Wire springs for HC relay terminal socket (ADX18005) are included. 2. You cannot use socket line holding clip when using the HJ relay terminal socket. Therefore, please procure a S1DX socket leaf holding clip B (ADX18012: dedicated socket leaf holding clip for HJ relay terminal socket). All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. S1DX Time range Time-out 2 Form C type Time-out 4 Form C type 0.05 to 0.5 s 0.1 to 1 s 0.1 to 3 s 0.2 to 5 s 0.5 to 10 s 1 to 30 s 3 to 60 s 0.1 to 3 min 0.5 to 10 min 1 to 30 min 3 to 60 min 0.1 to 3 h 0.05 to 0.5 s 0.1 to 1 s 0.1 to 3 s 0.2 to 5 s 0.5 to 10 s 1 to 30 s 3 to 60 s 0.1 to 3 min 0.5 to 10 min 1 to 30 min 3 to 60 min 0.1 to 3 h 12V DC Part No. S1DX-A2C0.5S-DC12V S1DX-A2C1S-DC12V S1DX-A2C3S-DC12V S1DX-A2C5S-DC12V S1DX-A2C10S-DC12V S1DX-A2C30S-DC12V S1DX-A2C60S-DC12V S1DX-A2C3M-DC12V S1DX-A2C10M-DC12V S1DX-A2C30M-DC12V S1DX-A2C60M-DC12V S1DX-A2C3H-DC12V S1DX-A4C0.5S-DC12V S1DX-A4C1S-DC12V S1DX-A4C3S-DC12V S1DX-A4C5S-DC12V S1DX-A4C10S-DC12V S1DX-A4C30S-DC12V S1DX-A4C60S-DC12V S1DX-A4C3M-DC12V S1DX-A4C10M-DC12V S1DX-A4C30M-DC12V S1DX-A4C60M-DC12V S1DX-A4C3H-DC12V 24V DC Part No. S1DX-A2C0.5S-DC24V S1DX-A2C1S-DC24V S1DX-A2C3S-DC24V S1DX-A2C5S-DC24V S1DX-A2C10S-DC24V S1DX-A2C30S-DC24V S1DX-A2C60S-DC24V S1DX-A2C3M-DC24V S1DX-A2C10M-DC24V S1DX-A2C30M-DC24V S1DX-A2C60M-DC24V S1DX-A2C3H-DC24V S1DX-A4C0.5S-DC24V S1DX-A4C1S-DC24V S1DX-A4C3S-DC24V S1DX-A4C5S-DC24V S1DX-A4C10S-DC24V S1DX-A4C30S-DC24V S1DX-A4C60S-DC24V S1DX-A4C3M-DC24V S1DX-A4C10M-DC24V S1DX-A4C30M-DC24V S1DX-A4C60M-DC24V S1DX-A4C3H-DC24V 48V DC Part No. S1DX-A2C0.5S-DC48V S1DX-A2C1S-DC48V S1DX-A2C3S-DC48V S1DX-A2C5S-DC48V S1DX-A2C10S-DC48V S1DX-A2C30S-DC48V S1DX-A2C60S-DC48V S1DX-A2C3M-DC48V S1DX-A2C10M-DC48V S1DX-A2C30M-DC48V S1DX-A2C60M-DC48V S1DX-A2C3H-DC48V S1DX-A4C0.5S-DC48V S1DX-A4C1S-DC48V S1DX-A4C3S-DC48V S1DX-A4C5S-DC48V S1DX-A4C10S-DC48V S1DX-A4C30S-DC48V S1DX-A4C60S-DC48V S1DX-A4C3M-DC48V S1DX-A4C10M-DC48V S1DX-A4C30M-DC48V S1DX-A4C60M-DC48V S1DX-A4C3H-DC48V 100 to 110V DC Part No. S1DX-A2C0.5S-DC110V S1DX-A2C1S-DC110V S1DX-A2C3S-DC110V S1DX-A2C5S-DC110V S1DX-A2C10S-DC110V S1DX-A2C30S-DC110V S1DX-A2C60S-DC110V S1DX-A2C3M-DC110V S1DX-A2C10M-DC110V S1DX-A2C30M-DC110V S1DX-A2C60M-DC110V S1DX-A2C3H-DC110V S1DX-A4C0.5S-DC110V S1DX-A4C1S-DC110V S1DX-A4C3S-DC110V S1DX-A4C5S-DC110V S1DX-A4C10S-DC110V S1DX-A4C30S-DC110V S1DX-A4C60S-DC110V S1DX-A4C3M-DC110V S1DX-A4C10M-DC110V S1DX-A4C30M-DC110V S1DX-A4C60M-DC110V S1DX-A4C3H-DC110V Notes: 1. Socket line holding clips for HC relay terminal socket (ADX18005) are included. 2. You cannot use socket line holding clip when using the HJ relay terminal socket. Therefore, please procure a S1DX socket leaf holding clip B (ADX18012: dedicated socket leaf holding clip for HJ relay terminal socket). 2) Power flicker (Please change “A” to “F” of the part number with the same specifications as the power on-delay type.) Example: S1DX-A2C1S-DC12V → S1DX-F2C1S-DC12V Time range 0.1 to 1 s 0.1 to 3 s Timed-out 0.2 to 5 s 2 Form C 0.5 to 10 s type 1 to 30 s 3 to 60 s 0.1 to 3 min 0.1 to 1 s 0.1 to 3 s Timed-out 0.2 to 5 s 4 Form C 0.5 to 10 s type 1 to 30 s 3 to 60 s 0.1 to 3 min 100 to 120 V AC Part No. S1DX-F2C1S-AC120V S1DX-F2C3S-AC120V S1DX-F2C5S-AC120V S1DX-F2C10S-AC120V S1DX-F2C30S-AC120V S1DX-F2C60S-AC120V S1DX-F2C3M-AC120V S1DX-F4C1S-AC120V S1DX-F4C3S-AC120V S1DX-F4C5S-AC120V S1DX-F4C10S-AC120V S1DX-F4C30S-AC120V S1DX-F4C60S-AC120V S1DX-F4C3M-AC120V 200 to 220 V AC Part No. S1DX-F2C1S-AC220V S1DX-F2C3S-AC220V S1DX-F2C5S-AC220V S1DX-F2C10S-AC220V S1DX-F2C30S-AC220V S1DX-F2C60S-AC220V S1DX-F2C3M-AC220V S1DX-F4C1S-AC220V S1DX-F4C3S-AC220V S1DX-F4C5S-AC220V S1DX-F4C10S-AC220V S1DX-F4C30S-AC220V S1DX-F4C60S-AC220V S1DX-F4C3M-AC220V 12 V DC Part No. S1DX-F2C1S-DC12V S1DX-F2C3S-DC12V S1DX-F2C5S-DC12V S1DX-F2C10S-DC12V S1DX-F2C30S-DC12V S1DX-F2C60S-DC12V S1DX-F2C3M-DC12V S1DX-F4C1S-DC12V S1DX-F4C3S-DC12V S1DX-F4C5S-DC12V S1DX-F4C10S-DC12V S1DX-F4C30S-DC12V S1DX-F4C60S-DC12V S1DX-F4C3M-DC12V 24 V DC Part No. S1DX-F2C1S-DC24V S1DX-F2C3S-DC24V S1DX-F2C5S-DC24V S1DX-F2C10S-DC24V S1DX-F2C30S-DC24V S1DX-F2C60S-DC24V S1DX-F2C3M-DC24V S1DX-F4C1S-DC24V S1DX-F4C3S-DC24V S1DX-F4C5S-DC24V S1DX-F4C10S-DC24V S1DX-F4C30S-DC24V S1DX-F4C60S-DC24V S1DX-F4C3M-DC24V 48 V DC Part No. S1DX-F2C1S-DC48V S1DX-F2C3S-DC48V S1DX-F2C5S-DC48V S1DX-F2C10S-DC48V S1DX-F2C30S-DC48V S1DX-F2C60S-DC48V S1DX-F2C3M-DC48V S1DX-F4C1S-DC48V S1DX-F4C3S-DC48V S1DX-F4C5S-DC48V S1DX-F4C10S-DC48V S1DX-F4C30S-DC48V S1DX-F4C60S-DC48V S1DX-F4C3M-DC48V 100 to 110 V DC Part No. S1DX-F2C1S-DC110V S1DX-F2C3S-DC110V S1DX-F2C5S-DC110V S1DX-F2C10S-DC110V S1DX-F2C30S-DC110V S1DX-F2C60S-DC110V S1DX-F2C3M-DC110V S1DX-F4C1S-DC110V S1DX-F4C3S-DC110V S1DX-F4C5S-DC110V S1DX-F4C10S-DC110V S1DX-F4C30S-DC110V S1DX-F4C60S-DC110V S1DX-F4C3M-DC110V Notes: 1. Socket line holding clips for HC relay terminal socket (ADX18005) are included. 2. You cannot use socket line holding clip when using the HJ relay terminal socket. Therefore, please procure a S1DX socket leaf holding clip B (ADX18012: dedicated socket leaf holding clip for HJ relay terminal socket). All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Timers Power ON-delay DC operating type S1DX 3) Power one-shot (Please change “A” to “S” of the part number with the same specifications as the power on-delay type.) Example: S1DX-A2C1S-DC12V → S1DX-S2C1S-DC12V Timers Time range 0.1 to 1 s 0.1 to 3 s Timed-out 0.2 to 5 s 2 Form C 0.5 to 10 s type 1 to 30 s 3 to 60 s 0.1 to 3 min 0.1 to 1 s 0.1 to 3 s Timed-out 0.2 to 5 s 4 Form C 0.5 to 10 s type 1 to 30 s 3 to 60 s 0.1 to 3 min 100 to 120 V AC Part No. S1DX-S2C1S-AC120V S1DX-S2C3S-AC120V S1DX-S2C5S-AC120V S1DX-S2C10S-AC120V S1DX-S2C30S-AC120V S1DX-S2C60S-AC120V S1DX-S2C3M-AC120V S1DX-S4C1S-AC120V S1DX-S4C3S-AC120V S1DX-S4C5S-AC120V S1DX-S4C10S-AC120V S1DX-S4C30S-AC120V S1DX-S4C60S-AC120V S1DX-S4C3M-AC120V 200 to 220 V AC Part No. S1DX-S2C1S-AC220V S1DX-S2C3S-AC220V S1DX-S2C5S-AC220V S1DX-S2C10S-AC220V S1DX-S2C30S-AC220V S1DX-S2C60S-AC220V S1DX-S2C3M-AC220V S1DX-S4C1S-AC220V S1DX-S4C3S-AC220V S1DX-S4C5S-AC220V S1DX-S4C10S-AC220V S1DX-S4C30S-AC220V S1DX-S4C60S-AC220V S1DX-S4C3M-AC220V 12 V DC Part No. S1DX-S2C1S-DC12V S1DX-S2C3S-DC12V S1DX-S2C5S-DC12V S1DX-S2C10S-DC12V S1DX-S2C30S-DC12V S1DX-S2C60S-DC12V S1DX-S2C3M-DC12V S1DX-S4C1S-DC12V S1DX-S4C3S-DC12V S1DX-S4C5S-DC12V S1DX-S4C10S-DC12V S1DX-S4C30S-DC12V S1DX-S4C60S-DC12V S1DX-S4C3M-DC12V 24 V DC Part No. S1DX-S2C1S-DC24V S1DX-S2C3S-DC24V S1DX-S2C5S-DC24V S1DX-S2C10S-DC24V S1DX-S2C30S-DC24V S1DX-S2C60S-DC24V S1DX-S2C3M-DC24V S1DX-S4C1S-DC24V S1DX-S4C3S-DC24V S1DX-S4C5S-DC24V S1DX-S4C10S-DC24V S1DX-S4C30S-DC24V S1DX-S4C60S-DC24V S1DX-S4C3M-DC24V 48 V DC Part No. S1DX-S2C1S-DC48V S1DX-S2C3S-DC48V S1DX-S2C5S-DC48V S1DX-S2C10S-DC48V S1DX-S2C30S-DC48V S1DX-S2C60S-DC48V S1DX-S2C3M-DC48V S1DX-S4C1S-DC48V S1DX-S4C3S-DC48V S1DX-S4C5S-DC48V S1DX-S4C10S-DC48V S1DX-S4C30S-DC48V S1DX-S4C60S-DC48V S1DX-S4C3M-DC48V 100 to 110 V DC Part No. S1DX-S2C1S-DC110V S1DX-S2C3S-DC110V S1DX-S2C5S-DC110V S1DX-S2C10S-DC110V S1DX-S2C30S-DC110V S1DX-S2C60S-DC110V S1DX-S2C3M-DC110V S1DX-S4C1S-DC110V S1DX-S4C3S-DC110V S1DX-S4C5S-DC110V S1DX-S4C10S-DC110V S1DX-S4C30S-DC110V S1DX-S4C60S-DC110V S1DX-S4C3M-DC110V Notes: 1. Socket line holding clips for HC relay terminal socket (ADX18005) are included. 2. You cannot use socket line holding clip when using the HJ relay terminal socket. Therefore, please procure a S1DX socket leaf holding clip B (ADX18012: dedicated socket leaf holding clip for HJ relay terminal socket). 4) Power one-cycle (Please change “A” to “C” of the part number with the same specifications as the power on-delay type.) Example: S1DX-A2C1S-DC12V → S1DX-C2C1S-DC12V Time range 0.1 to 1 s 0.1 to 3 s Timed-out 0.2 to 5 s 2 Form C 0.5 to 10 s type 1 to 30 s 3 to 60 s 0.1 to 3 min 0.1 to 1 s 0.1 to 3 s Timed-out 0.2 to 5 s 4 Form C 0.5 to 10 s type 1 to 30 s 3 to 60 s 0.1 to 3 min 100 to 120 V AC Part No. S1DX-C2C1S-AC120V S1DX-C2C3S-AC120V S1DX-C2C5S-AC120V S1DX-C2C10S-AC120V S1DX-C2C30S-AC120V S1DX-C2C60S-AC120V S1DX-C2C3M-AC120V S1DX-C4C1S-AC120V S1DX-C4C3S-AC120V S1DX-C4C5S-AC120V S1DX-C4C10S-AC120V S1DX-C4C30S-AC120V S1DX-C4C60S-AC120V S1DX-C4C3M-AC120V 200 to 220 V AC Part No. S1DX-C2C1S-AC220V S1DX-C2C3S-AC220V S1DX-C2C5S-AC220V S1DX-C2C10S-AC220V S1DX-C2C30S-AC220V S1DX-C2C60S-AC220V S1DX-C2C3M-AC220V S1DX-C4C1S-AC220V S1DX-C4C3S-AC220V S1DX-C4C5S-AC220V S1DX-C4C10S-AC220V S1DX-C4C30S-AC220V S1DX-C4C60S-AC220V S1DX-C4C3M-AC220V 12 V DC Part No. S1DX-C2C1S-DC12V S1DX-C2C3S-DC12V S1DX-C2C5S-DC12V S1DX-C2C10S-DC12V S1DX-C2C30S-DC12V S1DX-C2C60S-DC12V S1DX-C2C3M-DC12V S1DX-C4C1S-DC12V S1DX-C4C3S-DC12V S1DX-C4C5S-DC12V S1DX-C4C10S-DC12V S1DX-C4C30S-DC12V S1DX-C4C60S-DC12V S1DX-C4C3M-DC12V 24 V DC Part No. S1DX-C2C1S-DC24V S1DX-C2C3S-DC24V S1DX-C2C5S-DC24V S1DX-C2C10S-DC24V S1DX-C2C30S-DC24V S1DX-C2C60S-DC24V S1DX-C2C3M-DC24V S1DX-C4C1S-DC24V S1DX-C4C3S-DC24V S1DX-C4C5S-DC24V S1DX-C4C10S-DC24V S1DX-C4C30S-DC24V S1DX-C4C60S-DC24V S1DX-C4C3M-DC24V 48 V DC Part No. S1DX-C2C1S-DC48V S1DX-C2C3S-DC48V S1DX-C2C5S-DC48V S1DX-C2C10S-DC48V S1DX-C2C30S-DC48V S1DX-C2C60S-DC48V S1DX-C2C3M-DC48V S1DX-C4C1S-DC48V S1DX-C4C3S-DC48V S1DX-C4C5S-DC48V S1DX-C4C10S-DC48V S1DX-C4C30S-DC48V S1DX-C4C60S-DC48V S1DX-C4C3M-DC48V 100 to 110 V DC Part No. S1DX-C2C1S-DC110V S1DX-C2C3S-DC110V S1DX-C2C5S-DC110V S1DX-C2C10S-DC110V S1DX-C2C30S-DC110V S1DX-C2C60S-DC110V S1DX-C2C3M-DC110V S1DX-C4C1S-DC110V S1DX-C4C3S-DC110V S1DX-C4C5S-DC110V S1DX-C4C10S-DC110V S1DX-C4C30S-DC110V S1DX-C4C60S-DC110V S1DX-C4C3M-DC110V Notes: 1. Socket line holding clips for HC relay terminal socket (ADX18005) are included. 2. You cannot use socket line holding clip when using the HJ relay terminal socket. Therefore, please procure a S1DX socket leaf holding clip B (ADX18012: dedicated socket leaf holding clip for HJ relay terminal socket). Also, power flicker, power one-shot and power one-cycle types can be used with other time ranges (10 minutes to 3 hours). Please inquire. 24 V AC and 240 V AC types can also be ordered.  PC board terminal 1) Power ON-delay 0.05 to 0.5 s 0.1 to 1 s 0.1 to 3 s 0.2 to 5 s 0.5 to 10 s 1 to 30 s 3 to 60 s 0.05 to 0.5 s 0.1 to 1 s 100 to 120V AC Part No. S1DX-A2C0.5S-AC120VP S1DX-A2C1S-AC120VP S1DX-A2C3S-AC120VP S1DX-A2C5S-AC120VP S1DX-A2C10S-AC120VP S1DX-A2C30S-AC120VP S1DX-A2C60S-AC120VP S1DX-A4C0.5S-AC120VP S1DX-A4C1S-AC120VP 200 to 220V AC Part No. S1DX-A2C0.5S-AC220VP S1DX-A2C1S-AC220VP S1DX-A2C3S-AC220VP S1DX-A2C5S-AC220VP S1DX-A2C10S-AC220VP S1DX-A2C30S-AC220VP S1DX-A2C60S-AC220VP S1DX-A4C0.5S-AC220VP S1DX-A4C1S-AC220VP 24V DC Part No. S1DX-A2C0.5S-DC24VP S1DX-A2C1S-DC24VP S1DX-A2C3S-DC24VP S1DX-A2C5S-DC24VP S1DX-A2C10S-DC24VP S1DX-A2C30S-DC24VP S1DX-A2C60S-DC24VP S1DX-A4C0.5S-DC24VP S1DX-A4C1S-DC24VP 0.1 to 3 s 0.2 to 5 s 0.5 to 10 s 1 to 30 s 60 s S1DX-A4C3S-AC120VP S1DX-A4C5S-AC120VP S1DX-A4C10S-AC120VP S1DX-A4C30S-AC120VP S1DX-A4C60S-AC120VP S1DX-A4C3S-AC220VP S1DX-A4C5S-AC220VP S1DX-A4C10S-AC220VP S1DX-A4C30S-AC220VP S1DX-A4C60S-AC220VP S1DX-A4C3S-DC24VP S1DX-A4C5S-DC24VP S1DX-A4C10S-DC24VP S1DX-A4C30S-DC24VP S1DX-A4C60S-DC24VP Time range Time-out 2 Form C type Time-out 4 Form C type All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. S1DX Type Rated operating voltage Rated power consumption AC operating type 100 to 120V, 200 to 220V (50/60Hz common) Max. 3VA Timed -out 2 Form C: 7A 250V AC Timed -out 4 Form C: 5A 250V AC (resistive load) [Except 0.5s & 1s types] Within ±1%* [0.5s type]: Within ±(2%+10ms), [1s type]: Within ±(1%+10ms) (power off time change at the range of 0.1 s to 1 h) [Except 0.5s & 1s types] Within ±1%* [0.5s type]: Within ±(2%+10ms), [1s type]: Within ±(1%+10ms) (at the operating voltage changes between –20 to +10%) Within ±5% (at 20°C 68°F ambient temp. at the range of –10 to +50°C +14 to +122°F) Within ±10% (Full-scale value) Max. 100mΩ (at 1A, 6V DC) Min. 107 Min. 2×105 (at rated control capacity) 80 to 110% of rated operating voltage Between live and dead metal parts/input and output Min. 100MΩ Between contact sets (at 500V DC) Between contacts 1500Vrms for 1min Between live and dead metal parts/input and output 1500Vrms for 1min Between contact sets 1000Vrms for 1min Between contacts Max. 70°C 158°F Max. 0.1s 10 to 55Hz: 1 cycle/min single amplitude of 0.25mm (10min on 3 axes) 10 to 55Hz: 1 cycle/min single amplitude of 0.375mm (1h on 3 axes) Min. 98m/s2 (4 times on 3 axes) Min. 980m/s2 (5 times on 3 axes) –10 to 50°C +14 to 122°F 30 to 85% RH (at 20°C 68°F, non-condensing) Rated control capacity Operating time fluctuation & Power off time change error Time accuracy DC operating type 12V, 24V, 48V, 100 to 110V Max. 2W Voltage error Temperature error Setting error Contact resistance (Initial value) Mechanical (constant) Life Electrical (constant) Allowable operating voltage range Insulation resistance (Initial value) Breakdown voltage (Initial value) Temperature rise Power off time Functional Destructive Functional Shock resistance Destructive Ambient temperature Ambient humidity Vibration resistance Note: * Power one-shot type of 1 s type: +(2% + 10 ms) Dimensions (mm inch) Plug-in terminal The CAD data of the products with a 22.1 .870 5 .197 5 .197 4.1 .161 6.3 .248 6.4 .252 21.5 .846 Tolerance: ±0.5 ±.020 Timed-out 4 Form C type 13.35 .526 6.4 .252 57.9 2.280 52.7 2.075 UP ON mark can be downloaded from: http://panasonic-electric-works.net/ac Timed-out 2 Form C type CAD Data 28.5 1.122 CAD Data 13.35 .526 4.45 .175 4.1 .161 6.3 .248 6.4 .252 S1DX Printed circuit board terminal 1.5 3.5 .059 .138 5 0.5 .020 .197 57.9 2.280 52.7 2.075 22.1 .870 ON Timed-out 2 Form C type CAD Data UP 28.5 1.122 4.1 .161 6.3 .248 6.4 .252 21.5 .846 Timed-out 4 Form C type 13.35 .526 1.5 .059 5 .197 13.35 .526 4.45 .175 4.1 .161 6.3 .248 6.4 .252 S1DX Terminal layouts and Wiring diagram Timed-out 2 Form C type 1 4 Timed-out 4 Form C type 1 5 8 5 9 13 12 14 9 13 Operating voltage 2 6 10 3 PC board pattern Timed-out 2 Form C type 4.1 .161 4 7 8 11 12 14 Operating voltage Timed-out 4 Form C type 4.1 .161 10.4 .409 16.8 .661 13.35 .526 8-2 dia. hole 8-.079 dia. hole (For the DC operating type, terminal 14 is +, and terminal 13 is –.) 10.4 .409 16.8 .661 4.45 .175 8.9 .350 14-2 dia.hole 14-.079 dia. hole 13.35 .526 General tolerance: ±0.1 ±.004 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Timers Specifications S1DX Data 1. Load control capacity and life Timers • Switching capacity • Life curve No. of operations, ×104 Load current, A 10 7 5 2 Form C 4 Form C type type 1 1,000 No load life No load life: Min. 107 ope. Rated load life: Min. 2×105 ope. (250V AC cosφ = 1) 500 400 300 2 Form C type 0.1 200 100 0.01 10 100 1,000 4 Form C type 0 2 4 6 8 Load current, A Load voltage, V 2. Time accuracy 80 0.1 80 80 110 100 − 0.1 –0.1 − 0.2 − 0.2 –0.2 − 10 Ambient temperature, °C • Temperature error test II (typical) 3 s range, 200V AC operating type 4 pcs. Temperature error, % 0.5 110 100 Applied voltage, %V − 0.1 • Temperature error test I (typical) 3 s range, 100V AC operating type 4 pcs. 1 110 100 Applied voltage, %V 1 0.5 20 − 10 Ambient temperature, °C 50 • Temperature error test III (typical) 3 s range, 24V DC operating type 3 pcs. Temperature error, % Applied voltage, %V Voltage error, % 0.1 0.2 20 1 0.5 –10 Ambient temperature, °C 50 − 0.5 − 0.5 −1 −1 Temperature error, % 0.1 0.2 • Voltage error test III (typical) 3 s range, 24V DC operating type 3 pcs. Voltage error, % 0.2 • Voltage error test II (typical) 3 s range, 200V AC operating type 3 pcs. Voltage error, % • Voltage error test I (typical) 3 s range, 100V AC operating type 6 pcs. 20 50 –0.5 –1 3. Environmental durability • Surge testing Model Surge voltage • Noise testing 100 to 120V AC 200 to 220V AC 12V DC 4,000V 4,000V 1,000V 24V DC 1,000V 48V DC 4,000V 100 to 110V DC 4,000V Applied voltage: Unipolar full-wave voltage of ±(1.2 × 50) µs No. of times applied: 5 times, continuously Locations at which voltage is applied: Between power supply terminals (between 13 and 14) Results: No differences from withstand surge voltages listed above. • Cold and heat testing Conditions Left for 1 hour at high temperature of 80°C 176°F and low temperature of –25°C –13°F (25 times) Item Power line impulse noise Noise generation Results Noise simulator 1,000 V Rise: 1 ns Pulse width: 1 µs, 50 ns Repetition cycle: 10 ms Pulse polarity: Positive, negative Applied modes: Normal mode and Common mode Not affected • Humidity testing Results Appearance Operation Insulation performance —No irregularities Conditions Left for 500 hours at ambient temperature of 40°C 104°F, at relative humidity of 90 to 95%. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Results Appearance Operation Insulation performance —No irregularities S1DX Operation type Scale intervals Description Operation mode indicator color Time chart T Power ON-delay Timing operation will Power supply start when the power is supplied, and the control Timed-out contact (NO) output turns on after the Timed-out contact setting time. ON Power Ficker ON OFF OFF ON Yellow Power One-shot T ON T T OFF ON T Power One-cycle When the power is supplied, the control output turns on for one pulse after the setting time. OFF OFF ON T T ON OFF ON OFF t ON OFF Blue t
S1DX-A4C60S-DC24V 价格&库存

很抱歉,暂时无法提供与“S1DX-A4C60S-DC24V”相匹配的价格&库存,您可以联系我们找货

免费人工找货
S1DX-A4C60S-DC24V
    •  国内价格
    • 2+354.90922

    库存:0

    S1DX-A4C60S-DC24V
      •  国内价格
      • 2+445.74444

      库存:0