SF-AC

SF-AC

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    CONTROL SAFETY LIGHT CURTAIN 24V

  • 数据手册
  • 价格&库存
SF-AC 数据手册
721 FIBER SENSORS Safety Relay Unit SF-AC Related Information ■■General terms and conditions.............. F-7 ■■SG-B1 / SG-A1 / SG-B2................ P.643~ ■■Light Curtains / SF-C10..... P.495~ / P.703~ ■■General precautions...................... P.1501 LASER SENSORS PHOTOELECTRIC SENSORS Conforming to Machine & EMC Directive MICRO PHOTOELECTRIC SENSORS Listing AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS panasonic.net/id/pidsx/global Possible to create the highest level safety system Compatible up to control category 4 Installation time and labor can be saved due to the usage of detachable terminal blocks Control category 4 compatible with an SF4B series / SF4B-C series / SF4C series combination and control category 2 compatible with an SF2B series / SF2C series combination. As wiring can be performed with the terminal blocks removed, it is not necessary to detach the controller from the control panel when performing maintenance, thus reducing the number of installation procedures required. Also, when replacing the relay units, you simply insert new terminals without having to manipulate the wiring. A connecting terminal blocks are not needed As SF-AC incorporates a power supply terminals and synchronization lines terminals for the light curtain, so terminal blocks are not required. Selection Guide Previous Connecting terminal blocks are not required! Alarm input Light Curtains Safety Components Optical Touch Switch Power supply Control Units Definition of Sensing Heights SF-C10 SF-CL1T264T SF-AC Terminal blocks Shield Test input SF-AC Relay unit Power supply Unexpected start due to start-switch welding prevented Incorporates a 2-channel auxiliary output The unit is equipped with a trailing edge switching function, which causes an ON signal to be sent when the start switch signal is falling. This prevents unexpected starting which can occur if the start switch gets welded. SF-AC incorporates both an auxiliary output that operates together with the light curtain’s control output (OSSD), and an alarm output that functions together with the light curtain’s auxiliary output (non-safety output). These features allow for monitoring of light curtain activity. Normal switching BSF4-AH80 SF-AC Welding occurs Trailing edge switching Welding occurs Start switch Start switch Stop switch Stop switch Machine operation Machine operation Unexpected starting No unexpected starting Auxiliary output PLC Indicator light Start input / reset input 10 ms high-speed response We have realized the highest-class response time, 10 ms, for the relay output making for even more enhanced safety. Contactor (external relay) Light curtain SF-AC Monitoring Motor, etc. Safety Relay Unit SF-AC ORDER GUIDE Type 722 FIBER SENSORS Appearance Model No. Enabling path LASER SENSORS PHOTOELECTRIC SENSORS SF-AC Control category 4 NO contact × 3 MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS SPECIFICATIONS Model No. Item Connectable light curtains Applicable standards Control category Supply voltage Power consumption Power supply for light curtain Fuse (power supply) OSSD input Enabling path Utilization category Rated operational current (Ie)(Note 2) / Rated operational voltage Contact material / contacts Contact resistance Fuse Mechanical lifetime Electrical lifetime PRESSURE / FLOW SENSORS SF-AC PNP output type light curtains and Safety devices (SG-B1/A1/B2 series) manufactured by Panasonic Industrial SUNX EN 60947-5-1, EN ISO 13849-1(Category 4,PLe), EN ISO 13849-2, IEC 60947-5-1, ISO 13849-1(Category 4, PLe), ISO 13849-2, JIS B 9705-1 (Category 4), ANSI/UL 508, CAN/CSA C22.2 No.14, OSHA1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 ISO 13849-1 compliance up to Category 4 24 V DC ± 10 % Ripple P-P 10 % or less 1.7 W approx. (at 24 V DC) (without any connected devices) 24 V DC ± 10 % Hybrid fuse, triggering current: 1.1 A or more, Reset after power down PNP transistor 2 inputs (S1, S2) NO contact × 3 (13-14, 23-24, 33-34) AC-15, DC-13 (EN 60947-5-1) 6 A / 30 V DC, 6 A / 230 V AC, resistive load AgSnO, Self cleaning, positively driven 100 mΩ or less (initial value) 6 A (slow blow) 10 million times (switching frequency 180 times/min.) 100,000 times (switching frequency 20 times/min, rated load) B10d At min.load:20,000,000 / At max.load :400,000 (ISO 13849-1) Pick-up delay 40 ms or less (Automatic reset), 50 ms or less (Manual reset) Drop-out delay 10 ms or less Auxiliary output NC contact × 1 (41-42) Switching current Fuse Alarm output (Note 3) Switching current Indicators Fuse Power 1 A / 24 V DC 1 A (slow blow) NC contact × 1 (51-52) (Non-safety contact, related to input “Alarm in”) PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Max. 1 A / 24 V DC, Min. 5 mA / 24 V DC 1 A (slow blow) Green LED (lights up when the power is supplied) Internal circuit operation (Ui) Green LED (lights up when both conditions are present: unit is powered up and hybrid fuse is at normal state) Relay operation (K1 / K2) Green LED × 2 (lights up when enabling contacts are closed) Test input (Test) INDUCTIVE PROXIMITY SENSORS Yellow LED (lights up when X11-X12 is opened) Selection Guide Light Curtains External relay monitor function Incorporated Trailing edge function Incorporated Safety Components Incorporated (Selectable PNP or NPN test input polarity by internal switch) Optical Touch Switch Test input polarity selection function Excess voltage category Rated impulse-withstand voltage (Uimp) Environmental resistance Pollution degree Degree of protection Ambient temperature Ambient humidity Vibration resistance Shock resistance Material Connection terminal Tightening torque lll 4 kV 2 Enclosure : IP40, Terminal : IP20 −10 to +55 °C +14 to +131 °F, Storage: −10 to +55 °C +14 to +131 °F Definition of Sensing Heights SF-C10 35 to 85 % RH, Storage: 35 to 85 % RH SF-CL1T264T 10 to 55 Hz frequency, 0.35 mm 0.014 in amplitude in X, Y, Z directions for three times each (in power OFF state) SF-AC 15 G (150 m/s2 approx.) Effective impulse time 11ms Enclosure: Polycarbonate Removable European terminal 0.6 N·m Wiring cable 0.2 to 2.5 mm2 [including single wire or ferrule (sleeve)] Mounting Complies with 35 mm width DIN rail (EN 50022) Weight Control Units Net weight: 400 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) The rated operational current (le) varies depending on the ambient temperature. For details, refer to “Derating (p.726)” in “PRECAUTIONS FOR PROPER USE”. 3) The alarm output is "open" when the alarm input from the light curtain is ON. 723 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS Safety Relay Unit SF-AC I/O CIRCUIT AND WIRING DIAGRAMS Light curtain SF4B series wiring diagram (Supports to Control category 4) Light curtain SF2B series wiring diagram (Supports to Control category 2) MICRO PHOTOELECTRIC SENSORS AREA SENSORS Emitter LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES Auxiliary output (Yellow-green / Black) LASER MARKERS A1 E R +V +V X1 X2 X3 OSSD2 (White) L1 Synchronization (Orange / Black) Synchronization+(Orange) Shield 0 V (Blue) + V (Brown) OSSD1 (Black) + Synchronization − (Orange / Black) WIRE-SAVING SYSTEMS (Orange) SIMPLE WIRE-SAVING UNITS External device monitoring input (Yelloe-green) + V (Brown) Synchronization SENSOR OPTIONS Test input (emission halt input)(Pink) 0 V (Blue) PARTICULAR USE SENSORS Receiver Interlock setting input (Pale purple) (SF4B series only) Shield INDUCTIVE PROXIMITY SENSORS Set the test input polarity selection switch of SF-AC to the ‘PNP’ side. (Factory setting : PNP) Fuse 2 Test input polarity selection switch S1 S2 T_IN X11 X12 A_IN 51 13 23 33 41 K3 NPN + − 24V DC ±10% SF-AC CONTROL-LOGIC F1 Power A2 HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS E 0V K3 Ui R 0V PE * E: Emitter K1 R(F.G.) E (F.G.) R: Receiver FA COMPONENTS UV CURING SYSTEMS Fuse 1 (Note 1) PLC MACHINE VISION SYSTEMS TEST K4 PNP K2 RESET (Note 2) K1 K2 E R E R 52 Sy+ Sy+ Sy− Sy− L1 L2 L3 14 24 34 42 KA KA KB KA,KB: Magnet contactor N Notes: 1) If using the equipment with the manual reset, wire X1 to X2 as per the illustration above. If using with the automatic reset, disconnect X2 wire and connect it to X3. In this case, reset button is not required. 2) Use a momentary-type switch for the reset button. Time chart Light curtain SF4B Close Emission halt input Open Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF-C10 SF-CL1T264T SF-AC Light curtain SF4B ON OSSD1,OSSD2 OFF Safety relay unit SF-AC Close RESET button (X1-X2) Open Safety relay unit SF-AC Close Safety output (13-14,23-24,33-34) Open Safety relay unit SF-AC Close Auxiliary output (41-42) Open Operation time: 50 ms or less (When using manual reset) Response (recovery) time: 10 ms or less KB 3 M Safety Relay Unit SF-AC I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS Safety door switch SG-B1-SA-G□ / SG-B1-MA-G□ wiring diagram (Supports to Control Category 3) A2 11 22 51 31 Lock/Unlock signal (PLC etc.) 42 12 41 21 • Relay unit can be operated by reset after setting “UNLOCK → LOCK”. A1 52 32 724 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS 0V L E R A1 +V +V INDUCTIVE PROXIMITY SENSORS X1 X2 X3 S1 S2 T_IN X11 X12 A_IN 51 13 23 33 41 F1 NPN SF-AC CONTROL-LOGIC Power Ui K1 K3 E R 0V 0V A2 PRESSURE / FLOW SENSORS Fuse Fuse +24V K4 RESET K1 PARTICULAR USE SENSORS K2 PNP SENSOR OPTIONS K3 K2 E R E R 52 14 24 34 42 E R L1 L2 L3 (F.G.) (F.G.) Sy+ Sy+ Sy- Sy- PE SIMPLE WIRE-SAVING UNITS KA 0V WIRE-SAVING SYSTEMS KB N M 3 Safety door switch SG-B1-SA-G□ / SG-B1-MA-G□ wiring diagram (Supports to Control Category 3) 11 21 A2 A1 12 41 42 22 51 31 • Relay unit can be operated by reset after setting “UNLOCK → Door opening/closing → LOCK”. Lock/Unlock signal (PLC etc.) 52 MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC 32 HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS 0V L Fuse +24V E R A1 +V +V NPN SF-AC CONTROL-LOGIC Ui K1 K3 E R 0V 0V A2 FA COMPONENTS X1 X2 X3 S1 S2 T_IN X11 X12 A_IN 51 13 23 33 41 F1 Power Fuse K4 RESET K1 K2 PNP MACHINE VISION SYSTEMS UV CURING SYSTEMS K3 K2 E R E R 52 14 24 34 42 R E L1L2L3 (F.G.) (F.G.) Sy+ Sy+ Sy- Sy- PE KA 0V KB N Selection Guide M Light Curtains 3 Safety door switch SG-A1-02-□ / SG-A1-03-□ wiring diagram (Supports to Control Category 3) Safety Components Optical Touch Switch 11 Control Units 12 21 Definition of Sensing Heights 22 31 32 SF-C10 L Fuse +24V E R A1 +V +V NPN SF-AC CONTROL-LOGIC Ui A2 SF-AC X1 X2 X3 S1 S2 T_IN X11 X12 A_IN 51 13 23 33 41 F1 Power SF-CL1T264T Fuse E R 0V 0V K1 K3 PE K2 PNP K4 RESET K1 K2 K3 R E E R E R 52 14 24 34 42 (F.G.) (F.G.) Sy+ Sy+ Sy- SyL1L2 L3 KA 0V KB N M 3 725 FIBER SENSORS LASER SENSORS Safety Relay Unit SF-AC I/O CIRCUIT AND WIRING DIAGRAMS Safety door switch SG-B2-K2AD-□ / SG-B2-K2BD-□ / SG-B2-K2CD-□ wiring diagram (Supports to Control Category 3) PHOTOELECTRIC SENSORS LOCK MICRO PHOTOELECTRIC SENSORS 11 12 41 21 22 • Relay unit can be operated by reset after setting “UNLOCK → LOCK”. UNLOCK 42 52 51 AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS L Fuse +24V E R A1 +V +V X1 X2 X3 S1 S2 T_IN X11 X12 A_IN 51 13 23 33 41 F1 CONTROL-LOGIC Ui A2 NPN SF-AC Power Fuse K3 K1 K4 RESET K1 K2 PNP K3 K2 R E R E R 52 14 24 34 42 PE E (F.G.) (F.G.) Sy+ Sy+ Sy- SyL1 L2 L3 E R 0V 0V KA 0V KB WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES N Safety door switch SG-B2-K2AD-□ / SG-B2-K2BD-□ / SG-B2-K2CD-□ wiring diagram (Supports to Control Category 3) LASER MARKERS LOCK 21 22 • Relay unit can be operated by reset after setting “UNLOCK → Door opening/closing → LOCK”. UNLOCK 12 41 11 PLC 51 42 52 HUMAN MACHINE INTERFACES L ENERGY CONSUMPTION VISUALIZATION COMPONENTS +24V FA COMPONENTS E R A1 +V +V MACHINE VISION SYSTEMS UV CURING SYSTEMS M 3 Fuse X1 X2 X3 S1 S2 T_IN X11 X12 A_IN 51 13 23 33 41 F1 Power NPN SF-AC CONTROL-LOGIC Ui K3 A2 Fuse E R 0V 0V K1 K2 PNP K4 RESET K1 K2 K3 PE E R E R E R 52 14 24 34 42 L1L2 L3 (F.G.) (F.G.) Sy+ Sy+ Sy- SyKA 0V Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF-C10 SF-CL1T264T SF-AC KB N M 3 Safety Relay Unit SF-AC 726 PRECAUTIONS FOR PROPER USE Note that SF-AC cannot be connected to the NPN output (equivalent) type light curtain. FIBER SENSORS Derating LASER SENSORS Rated operation current (le) of enabling path changes depending on ambient temperature. PHOTOELECTRIC SENSORS 7 Please install and connect ferrule (stick) terminal when the lead wire of the connected equipment is a twisted wire. Please do not connect the twisted wire directly with the terminal. Tighten the wiring to the wiring terminal block at tightening torque of 0.6 N m. Others Rated operational current Ie(A) Wiring 6 AREA SENSORS 5 LIGHT CURTAINS / SAFETY COMPONENTS 4 PRESSURE / FLOW SENSORS 3 2 INDUCTIVE PROXIMITY SENSORS 1 0 The seal as shown in the drawing on the right is stuck to the engagement point of unit. When the seal is peeled off or broken, this equipment will not be certified as ‘Safety equipment’. MICRO PHOTOELECTRIC SENSORS 35 95 40 45 50 104 113 122 Ambient temperature (°C°F) 55 131 PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Functional description MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES Power indicator (Green) [lights up when the power is supplied] LASER MARKERS Test input indicator (Yellow) [lights up when X11-X12 is opened] Internal circuit operation indicator (Green) lights up when both conditions are present: unit is powered up and hybrid fuse is at normal state PLC HUMAN MACHINE INTERFACES K1 relay operation indicator (Green) [lights up when enabling contacts are closed] ENERGY CONSUMPTION VISUALIZATION COMPONENTS Test input polarity selection switch Used to change the polarity of the test input. For front cover detachment setting. K2 relay operation indicator (Green) [lights up when enabling contacts are closed] FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. Selection Guide Light Curtains Safety Components 120 100 90 4.724 3.937 3.543 Optical Touch Switch Control Units Definition of Sensing Heights Suitable for 35 mm 1.378 in width DIN rail 120 4.803 45 1.772 SF-C10 SF-CL1T264T SF-AC
SF-AC 价格&库存

很抱歉,暂时无法提供与“SF-AC”相匹配的价格&库存,您可以联系我们找货

免费人工找货