SF-C14EX

SF-C14EX

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    CONTROL SAFETY GEN PURPOSE 24V

  • 数据手册
  • 价格&库存
SF-C14EX 数据手册
703 FIBER SENSORS Exclusive Control Unit for Light Curtain SF-C10 SERIES Related Information ■■General terms and conditions.............. F-7 ■■General precautions...................... P.1501 ■■SF4B-C / SF4C / SF4B / SF2B................P.499~ / P.531~ / P.565~ / P.609~ ■■Korea’s S-mark.............................. P.1506 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Conforming to Machine, Low Voltage (SF-C11/C13 only) & EMC Directive Listing Certified Certified (SF-C11/C13 only) PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS panasonic.net/id/pidsx/global STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS Less setup time for safety circuits Plug-in type control unit Quick-connection Connecting to the light curtain is done using plug-in connections, which shortens setup and replacement time. UV CURING SYSTEMS SF-C11 / SF-C14EX(-01) Easy setup requiring no torque control A spring method is used for the terminal blocks for connections other than to the light curtain. There is no need to control tightening torques for Flat-tipped screwdriver these Lead wire terminal blocks. Ferrule (sleeve) terminal (Please arrange separately.) Removable terminal blocks reduce maintenance time Removable terminal blocks are used. This reduces the work required for reconnecting wiring during maintenance. Removable! Uses a spring method! Selection Guide Light Curtains Safety Components Optical Touch Switch Release button Lead wire insertion hole Control Units Definition of Sensing Heights SF-C10 SF-CL1T264T SF-AC Robust type control unit SF-C12 Metal enclosure with a IP65 protective structure The strong metal enclosure has a built-in safety relay. It has an IP65 protective structure, so that it can be set up individually without needing to be inserted into a control panel. IP65 Slim type control unit Slim design 22.5 mm 0.886 in thickness, so can be inserted even into narrow spaces inside panels. Metal enclosure Slim 22.5 mm 0.886 in Connecting to the light curtain is done using plug-in connector connections SF-C13 Spring-type terminal block No torque control needed Exclusive Control Unit for Light Curtain SF-C10 SERIES Building of muting control circuits is easy SF-C14EX(-01) The method used to build the safety circuit is selectable It is possible to build muting control circuits using a stand-alone light curtain from the SF4B series. The SF-C14EX(-01) application expansion unit allows the light curtain, muting sensors and muting lamps to be connected together directly, so that muting control circuits can be built very easily. Building method Using SF4B series functions Building method Using the SF-C14EX(-01) internal circuits Muting control Muting control Muting lamps Muting sensors Exclusive mating cable for SF-C14EX(-01) Safety output Terminal blocks SF4B series External devices (Force-guided relay, etc.) No safety relay unit needed ! Low cost s space! Save Muting lamps Muting sensors SF4B series Safety output SF-C14EX(-01) External devices (Force-guided relay, etc.) Light curtain connector connection. Terminal blocks for peripheral circuits available. g! Less wirin aintenance! m Reduced Motor, etc. 704 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Motor, etc. MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES Both safety and productivity can be obtained by stopping only one part of the device SF-C14EX(-01) LASER MARKERS Three safety circuit systems packaged into a single unit! PLC Three safety circuit systems 1 Light curtain output circuit, 2 Muting control circuit, and 3 Emergency stop circuit are packaged into a single unit. Functions that require multiple safety relay units and muting control units can be concentrated into a single unit, which results in large space savings, less wiring and less installation work. Previous model High-speed response 14 ms (Including light curtain) High-speed response has been achieved due to the adoption of the semiconductor output. Avoids the response delays that occur when using more than one safety relay unit, and greatly reduces the light curtain safety distance and improves ease of working. Of course, it is not necessary to exchange the safety relays within the unit anymore, which contributes to the reduction of running cost. SF-C14EX(-01) Including light curtain response time Light curtain 1 Muting sensor Emergency stop button 2 SF4B series Muting sensor 3 1 Emergency stop button 2 3 pace! Saves s g! in ir w s s ! e L struction n o c s Les Safety relay Muting unit unit Furthermore, due to the semiconductor output, Safety relay unit SF-C14EX(-01) 1 2 3 2 2 3 External contactor (Force-guided relay, etc.) 1 1 (Force-guided relay, etc.) 3 Motor 1 Light curtain output circuit 3 Emergency stop circuit 1 2 Motor 2 Muting control circuit 3 ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Previous model 14 ms 10 ms 20 ms 35 ms Customer's logical connection circuit Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units SF-C14EX(-01) Customer's logical connection circuit External contactor High response speed of 14 ms! Greatly reduced safety distance! HUMAN MACHINE INTERFACES ms! ed! Total 14 not requir cement is la p re y la Re Definition of Sensing Heights SF-C10 SF-CL1T264T SF-AC 705 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC Exclusive Control Unit for Light Curtain SF-C10 SERIES Three safety circuit systems can be controlled independently so that equipment can be stopped all together or partially SF-C14EX(-01) Motors that use muting control and those that do not use it can be controlled independently! Controls the motors that use muting control (robots) and the motors that do not use muting control (turntables) with a single unit. When the workpiece comes in, the turntable can be stopped and the robot can keep operating condition, to protect the safety of the operator and to maintain productivity. SF-C14EX(-01) controls three safety output systems using only a single unit! Safety circuit 1 : Linked to light curtain beam received / interrupted status (partial stop) 3 1 2 When the light curtain is interrupted (when an workpiece enters or a person intrudes), this circuit switches off (open) the safety output and stops the turntable. Safety circuit 2 : Linked to muting control (partial stop) If an workpiece enters when the turntable has stopped normally, (muting conditions are achieved), this circuit allows the robot to operate. If an workpiece enters while the turntable is turning (muting conditions are not achieved), this circuit switches off (open) the safety output and stops the robot. Robot Motor using muting Safety circuit 3 : Linked to emergency stop input (all stop) When the emergency stop button is pressed, this circuit switches off (open) the safety output and stops all equipment (turntable and robot). Emergency stop button HUMAN MACHINE INTERFACES Limit switch For muting input SF4B series Turntable Motor not using muting ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Equipped with blown lamp output for muting lamp If a lamp in one of the two muting lamps that are connected to the unit blows, a warning is output. It is possible to replace the lamp before both lamps blow and the equipment stops. In addition, auxiliary output that is linked to the muting function, override function and light curtain control output is also available. Function Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF-C10 SF-CL1T264T SF-AC Equipped with a digital indicator so that error details can be understood at a glance! If a problem should occur, the same output (OFF signal) as when the object was detected is maintained in order to ensure safety, and the details of the error appear on the digital display. Operation Auxiliary output 1 Muting output ON when the muting function is invalid Auxiliary output 2 Override output ON when the override function is invalid Auxiliary output 3 Blown lamp output ON when the muting lamp is normal Auxiliary output 4 Light curtain auxiliary output ON when the light curtain is in light interrupted condition Supports both PNP and NPN polarities All Models A single model can be used for PNP / NPN input switching, reducing the number of parts that need to be registered. NPN PNP Polarity selection switch Exclusive Control Unit for Light Curtain SF-C10 SERIES ORDER GUIDE 706 FIBER SENSORS LASER SENSORS Designation Appearance Connector connection type control unit Robust type control unit Slim type control unit SF-C11 SF-C12 SF-C13 SF-C14EX Handy-controller non-compatible type Application expansion unit for SF4B series Model No. SF-C14EX-01 Description Applicable cable (Note) Light curtain connection cable: SFB-CB□ (For SF4B series) SF2B-CB□ (For SF2B series) Extension cable: SFB-CCJ10□ Use 8-core cable with connector to connect to the light curtain. Compatible with up to control category 4. Interference prevention wires and muting function cannot be used. Use 12-core cable with connector to connect to the light Light curtain connection cable: curtain. Interference prevention wires can be used. SFB-CB05-MU Compatible with up to control category 4. Extension cable: SFB-CCJ10□-MU Muting function cannot be used. Light curtain connection cable: SFB-CCB□(-MU) (For SF4B series) SF2B-CCB□ (For SF2B series) Extension cable: SFB-CC□(-MU) Use a discrete wire cable to connect to the light curtain. Muting function and interference prevention wires can be used. Compatible with up to control category 4. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS The muting control function and emergency stop input are Light curtain connection cable: equipped, expanding the applications of the light curtains. SFB-CB□-EX It can be connected to the light curtains using the exclusive Extension cable: SFB-CCJ10□ connection cable. Compatible with up to control category 4. Note: Refer to the SF4B series (p.576~) and SF2B series (p.614) for details of applicable cable. SF-C12 spare relay set A set of spare relays (2 safety relays and 1 removal tool) is available for the safety relay that is built into the SF-C12. Model No.: SF-C12-RY MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF-C10 SF-CL1T264T SF-AC 707 Exclusive Control Unit for Light Curtain SPECIFICATIONS FIBER SENSORS Model No. Item PHOTOELECTRIC SENSORS Connectable light curtains MICRO PHOTOELECTRIC SENSORS Applicable standards LIGHT CURTAINS / SAFETY COMPONENTS Control category Enabling path Contact resistance MACHINE VISION SYSTEMS UV CURING SYSTEMS Electrical lifetime Pick-up delay (Auto reset / Manual reset) Response time Auxiliary output Contact protection fuse rating AgSnO, self cleaning, positively driven AgNiO + 0.2 µm 0.008 mil Au plating, self cleaning, positively driven AgSnO, self cleaning, positively driven 100 mΩ or less (initial value) 50 mΩ or less (initial value) 100 mΩ or less (initial value) 6 A (slow blow) 3 A (slow blow) 4 A (slow blow) 10 million operations or more (switching frequency 180 operations/min.) (Note 3) 100,000 operations or more (switching frequency 20 operations/min., 230 V AC / 3 A resistive load) (Note 3) 80 ms or less / 90 ms or less 30 ms or less / 30 ms or less 80 ms or less / 90 ms or less 10 ms or less 14 ms or less 10 ms or less Safety relay contact (NC contact) ×1 (41-42) (Related to enabling path) Safety relay contact (NC contact) × 1 (31-32) (Related to enabling path) Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path) 2 A (slow blow) 3 A (slow blow) 2 A (slow blow) – PNP open‑collector transistor • Max. source current: 60 mA • Applied voltage: same as supply voltage between the semiconductor auxiliary output and +V • Residual voltage: 2.3 V or less (at source current 60 mA) • Leakage current: 2 mA or less Related to auxiliary output of light curtain – On when the light curtain is interrupted ll lll ll NPN open-collector transistor PNP open-collector transistor • Max. source current: 60 mA • Max. sink current: 60 mA • Applied voltage: same • Applied voltage: same as supply voltage as supply voltage Semiconductor auxiliary output between the semiconductor between the semiconductor (AUX) auxiliary output and 0 V auxiliary output and +V • Residual voltage: 2.3 V or less • Residual voltage: 1.5 V or less (at sink current 60 mA) (at source current 60 mA) • Leakage current: 2 mA or less • Leakage current: 2 mA or less Output operation Excess voltage category Power supply (Ui) Green LED (lights up when the power is ON) Enabling path [OUT (Note 4)] Interlock (INTER_LOCK) Fault (FAULT) External relay monitor function Green LED (lights up when enabling contacts are closed) Yellow LED (lights up when enabling contacts are opened) – Yellow LED (lights up when enabling contacts are opened) Yellow LED (blinks when fault occurs) Orange LED (lights up when two light curtain input polarity selection switch settings are different) Yellow LED (blinks when fault occurs) Incorporated Incorporated (Note 5) Incorporated Trailing edge function Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights Polarity selection function (Note 6) Protection Ambient temperature Ambient humidity Vibration resistance Connection terminal SF-C10 Enclosure material SF-CL1T264T Weight SF-AC Incorporated Incorporated (Sliding switch allows selection of plus / minus ground) Minus ground: Correspond to PNP output light curtain Plus ground: Correspond to NPN output light curtain Pollution degree Environmental resistance Selection Guide NO contact × 3 (13-14, 23-24, 33-34) Rated operation voltage / current 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) 30 V DC / 3 A, Min. applicable load: 15 mA (at 24 V DC) 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) Indicators FA COMPONENTS NO contact × 2 (13-14, 23-24) AC-15, DC-13 (IEC 60947-5-1) Mechanical lifetime SIMPLE WIRE-SAVING UNITS ENERGY CONSUMPTION VISUALIZATION COMPONENTS NO contact × 3 (13-14, 23-24, 33-34) 30 V DC / 6 A, 230 V AC / 6 A, resistive load 24 V DC / 1 A, resistive load 30 V DC / 4 A, 230 V AC / 4 A, resistive load Rated operation voltage (Ue) / (For inductive load, during contact protection) (For inductive load, during contact protection) (For inductive load, during contact protection) Rated operation current (le) Min. applicable load: 10 mA (at 24 V DC) (Note 2) Min. applicable load: 15 mA (at 24 V DC) Min. applicable load: 10 mA (at 24 V DC) (Note 2) Contact protection fuse rating HUMAN MACHINE INTERFACES ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards Utilization SENSOR OPTIONS PLC Light curtain manufactured by PID SUNX 24 V DC ±10 %   Ripple P-P 10 % or less / 100 mA or less (without light curtain) Contact material / contacts LASER MARKERS SF4B series Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down PARTICULAR USE SENSORS STATIC ELECTRICITY PREVENTION DEVICES SF4B / SF2B series IEC 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe), JIS B 9704-1 (Type 4), JIS B 9705-1(Category 4), ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2, excluding SF-C12) Fuse rating INDUCTIVE PROXIMITY SENSORS MEASUREMENT SENSORS SF-C13 Supply voltage / Current consumption PRESSURE / FLOW SENSORS WIRE-SAVING SYSTEMS SF-C12 Incorporated (Cable connection allows selection of plus / minus ground) Minus ground: Correspond to PNP output light curtain Plus ground: Correspond to NPN output light curtain 2 Enclosure: IP40, Terminal: IP20 IP65 Enclosure: IP40, Terminal: IP20 –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F 30 to 85 % RH, Storage: 30 to 95 % RH 35 to 85 % RH, Storage: 35 to 85 % RH 30 to 85 % RH, Storage: 30 to 95 % RH Resistance / malfunction 10 to 55 Hz frequency, 0.35 mm 0.014 in Resistance 10 to 55 Hz frequency, 0.75 mm 0.030 in Resistance / malfunction 10 to 55 Hz frequency, 0.35 mm 0.014 in amplitude in X, Y, and Z directions for twenty times each amplitude in X, Y, and Z directions for two hours each amplitude in X, Y, and Z directions for twenty times each Detachable spring-cage terminal European terminal ABS Die-cast aluminum ABS Net weight: 320 g approx. Net weight: 1 kg approx. Net weight: 200 g approx. Notes: 1) W  here measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) If several SF-C11 or SF-C13 units are being used in line together, leave a space of 5 mm 0.197 in or more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs at right. 3) Relay switching lifetime will vary depending on factors such as the type of load, the switching frequency, and ambient conditions. 4) The operation indicator is marked as “Enabling” on the unit for SF-C12. 5) Terminals for utilizing the functions of the SF4B series are available. 6) Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground. Dilating when SF-C11 units are mounted close together 6 5 4 3 2 1 0 32 Spring-cage terminal Dilating when SF-C13 units are mounted close together Rated operation current (A) AREA SENSORS SF-C11 Rated operation current (A) LASER SENSORS SF-C10 SERIES 35 40 45 50 55 95 104 113 122 131 Ambient temperature (°C °F) 6 5 4 3 2 1 0 32 35 40 45 50 55 95 104 113 122 131 Ambient temperature (°C °F) Exclusive Control Unit for Light Curtain SF-C10 SERIES SPECIFICATIONS Model No. Item Connectable light curtains Applicable standards Control category Supply voltage Current consumption Safety outputs Safety output 1 Safety output 2 Safety output 3 Operation mode (Output operation) Protection circuit (Short-circuit protection) Response time Auxiliary outputs Auxiliary output 1 Auxiliary output 2 Auxiliary output 3 Auxiliary output 4 (Note 5) Operation mode (Output operation) Protection circuit (Short-circuit protection) Muting lamp output Environmental resistance Protection circuit (Short-circuit protection) Protection Ambient temperature Ambient humidity Dielectric strength voltage FIBER SENSORS SF-C14EX(-01) (Note 2) SF4B series IEC 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496 (Type 4), ISO 13849-1 (Category 4, PLe), JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4), ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) ISO 13849-1 (EN 954-1, JIS B 9705-1) compliance up to Category 4, PLe standards 24 V DC ±10 % Ripple P-P 10 % or less 0.2 A or less (Excluding light curtain and other external connecting device) PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch) • Maximum source current: 200 mA • Maximum sink current: 200 mA • Applied voltage: same as supply voltage • Applied voltage: same as supply voltage (between the safety output and +V) (between the safety output and 0 V) • Residual voltage: 2 V or less (at 200 mA source current) • Residual voltage: 2 V or less (at 200 mA sink current) Safety output 1: ON when the light curtain is in light receiving condition, OFF when the light curtain is in light interrupted condition (Note 3) Safety output 2: ON when the light curtain is in light receiving condition or the muting function is valid OFF when the light curtain is in light interrupted condition and the muting function is invalid (Note 3) Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid Incorporated OFF response: 14 ms or less (Safety output 1 and 2: including the response time of the light curtain) ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note 4) PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch) • Maximum source current: 60 mA • Maximum sink current: 60 mA • Applied voltage: same as supply voltage • Applied voltage: same as supply voltage (between the auxiliary output and +V) (between the auxiliary output and 0 V) • Residual voltage: 2 V or less (at 60 mA sink current) • Residual voltage: 2 V or less (at 60 mA source current) Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is valid Auxiliary output 2: ON when the override function is invalid, OFF when the override function is valid Auxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is error Auxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition (Note 5) Incorporated Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit) Incorporated Enclosure: IP40, Terminal: IP20 10 to 55 Hz frequency, 0.35 mm 0.014 in amplitude in X, Y and Z directions for two hours each Weight MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 1,000 V AC for one min. between all supply terminals connected together and enclosure Vibration resistance Connection terminal PHOTOELECTRIC SENSORS 30 to 85 % RH, Storage: 30 to 95 % RH 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure Material LASER SENSORS –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F Insulation resistance Shock resistance 708 30 G acceleration in X, Y and Z directions for three times each Enclosure: ABS Detachable spring-cage terminal Net weight: 250 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) S  F-C14EX-01 is Handy-controller non-compatible type. 3) Both safety output 1 and 2 are OFF when the emergency stop is valid regardless of whether the light curtain is in the light receiving or light interrupted condition. 4) The auto-reset cannot be used with safety output 3. 5) The auxiliary output incorporated in the SF4B series is output. Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF-C10 SF-CL1T264T SF-AC 709 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS LIGHT CURTAIN WIRING DIAGRAMS Wiring diagram of SF-C11 and SF4B series or SF2B series (Control category 4 or 2) For PNP output (minus ground) UV CURING SYSTEMS When connecting the SF-C11 to the light curtains, make sure to use the 8-core connection cable with a connector. Refer to the SF4B series and SF2B series for details. SFB-CB□, SF2B-CB□, SFB-CCJ10□ • Set the light curtain input polarity selection switch to the PNP side and ground the 0 V line. Light curtain input polarity selection switch +24 V DC A1 F Receiver side connector L1 RESET (Note 1) (Note 1) (Note 2) X1 X2 X3 A B Ui FUSE1 FUSE2 13 23 Terminal arrangement diagram 33 41 K1 NPN SF-C11 control circuit PNP K2 Emitter side connector F.G. OUT A2 AUX INTER_LOCK FAULT 14 24 34 42 T1 KA, KB: Magnet contactor KB KA N T2 0 V TEST (Note 3) L1 L2 L3 KB KA M 3 Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) E  mission halt occurs when the test (TEST) button is open, and emission occurs when the test (TEST) button is short-circuited. If not using the test (TEST) button, short-circuit T1 and T2. However, in case of SF2B series, use a test rod or similar to interrupt the light in order to carry out self-diagnosis separately. • In the above diagram, set the light curtain input polarity selection switch to the NPN side and ground the + side. F.G. Emitter side connector X1 X2 X3 A Ui SF-C11 control circuit AUX T2 Receiver side connector Control Units SF-C10 SF-CL1T264T SF-AC MPCE1 FUSE FUSE MPCE2 Definition of Sensing Heights OSSD2 +24 V DC OSSD1 EDM (External relay monitor) Synchronization wire + Synchronization wire – 0V Shielded wire 4 Note: It is not used with the SF2B series. FAULT T1 When connecting the SF-C12 to the light curtains, make sure to use the 12-core connection cable with a connector. Refer to the SF4B series for details. SFB-CB05-MU (Cable length: 0.5 m 1.640 ft) SFB-CCJ10E-MU (Extension cable for emitter, cable length: 10 m 32.808 ft) SFB-CCJ10D-MU (Extension cable for receiver, cable length: 10 m 32.808 ft) Terminal arrangement diagram Light curtain input polarity selection switches PNP Safety Components Interlock (Note) +24 V DC Emission halt Auxiliary output Synchronization wire + Synchronization wire – 0V Shielded wire 8 For PNP output (minus ground) Optical Touch Switch 1 7 Wiring diagram of SF-C12 and SF4B series (Control category 4) X1 X2 T1 T2 E– E+ R– R+ FB1 FB2 FB3 FB4 32 31 24 23 14 13 A1 A2 FG Receiver side connector 3 NPN PNP 0 V TEST Emission halt input switch (Note) (Note) Interference prevention wire Emitter side connector Test output terminal Test input terminal Semiconductor auxiliary output Emitter side connector 5 INTER_LOCK Not used Connector pin No. 6 OUT A2 Function +24 V DC 0V Safety output (NO contact × 3) Auxiliary output (NC contact × 1) Reset output terminal Reset input terminal (Manual) Reset input terminal (Automatic) 2 6 B F Receiver side connector 8 5 RESET A1 NPN Light Curtains 1 7 • Set the two light curtain input polarity selection switches to the PNP side and connect the F.G. terminal to the 0 V line. Selection Guide 2 3 4 +24 V DC Terminal A1 A2 13-14, 23-24, 33-34 41-42 X1 X2 X3 A B T1 T2 AUX Pin layout for light curtain connectors Light curtain input polarity selection switch For NPN output (plus ground) FA COMPONENTS MACHINE VISION SYSTEMS SF-C10 SERIES Enabling path Auxiliary Power input output 24 V DC ±10 % Note: The above diagram is when using manual reset. If automatic reset is used, connect a normal close-type pushbutton switch between T1 and T2 and leave between X1 and X2 open. Terminal Function FG A2 A1 13-14, 23-24 31-32 FB4 FB3 FB2 FB1 Frame ground (F.G.) terminal 0V +24 V DC Safety output (NO contact × 2) Auxiliary output (NC contact × 1) External relay monitor terminal 2 External relay monitor terminal 1 • In the above diagram, set the two light curtain input polarity selection switches to the NPN side and connect the F.G. terminal to the + side. Terminal R+ R– E+ E– T2 T1 X2 X1 Function Interference prevention wire – (Receiver side) Interference prevention wire + (Receiver side) Interference prevention wire – (Emitter side) Interference prevention wire + (Emitter side) Emission halt input terminal Automatic reset / manual reset selection terminal Manual reset: X1 – X2 short-circuited Pin layout for light curtain connectors 1 10 2 9 3 12 11 8 For NPN output (plus ground) X1 X2 T1 T2 EE+ RR+ FB1 FB2 FB3 FB4 32 31 24 23 14 13 A1 A2 FG FIBER SENSORS Exclusive Control Unit for Light Curtain 7 6 5 4 Note: Input and output for pin Nos. 11 and 12 are not used by this product Connector pin No. Emitter side connector Receiver side connector 1 2 3 4 5 6 7 8 9 10 11 12 Interlock +24 V DC Emission halt Auxiliary output Synchronization wire + Synchronization wire – 0V Shielded wire Interference prevention wire + Interference prevention wire – (Override input) (Muting lamp output) OSSD2 +24 V DC OSSD1 EDM (External relay monitor) Synchronization wire + Synchronization wire – 0V Shielded wire Interference prevention wire + Interference prevention wire – (Muting input 1) (Muting input 2) Exclusive Control Unit for Light Curtain 710 SF-C10 SERIES LIGHT CURTAIN WIRING DIAGRAMS FIBER SENSORS LASER SENSORS Wiring diagram of SF-C13 and SF4B series or SF2B series (Control category 4 or 2) For PNP output (minus ground) For NPN output (plus ground) • Connect the light curtain control outputs OSSD1 and OSSD2 to S1 and S2 respectively. • Connect the light curtain control outputs OSSD1 and OSSD2 to S4 and S2 respectively and ground the + side. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Emitter Receiver Cable color: Gray with black line Cable color: Gray +V (Brown) +24 V DC INDUCTIVE PROXIMITY SENSORS (Orange / Black) Synchronization – Output Emission halt Auxiliary output Interlock setting input polarity input / Reset input (Yellow-green / (Pale purple) (Note 4) setting wire (Pink) (Note 3) Black) Open (Shield) (Note 5) 0 V +V Load (Blue) (Brown) Output polarity setting wire 0 V (Shield) Load (Blue) (Note 5) External device monitoring input (Yellow-green) Output polarity setting wire (Shield) (Note 5) S2 S3 (Note 1) FUSE1 S4 X1 X2 X3 F 13 23 OSSD1 (Black) (Note 1) FUSE1 FUSE2 33 41 A1 F.G. S1 S2 S3 S4 X1 X2 X3 13 23 F OUT 0V F.G. INTER_LOCK KA, KB: Magnet contactor KA N STATIC ELECTRICITY PREVENTION DEVICES RESET (Note 1, 2) LASER MARKERS K2 FAULT 14 24 MEASUREMENT SENSORS 33 41 SF-C13 control circuit K2 AUX FUSE2 K1 Ui SF-C13 control circuit A2 WIRE-SAVING SYSTEMS L1 K1 Ui SIMPLE WIRE-SAVING UNITS OSSD2 (White) L1 S1 SENSOR OPTIONS 0 V (Blue) OSSD2 (White) A1 PARTICULAR USE SENSORS External device monitoring input (Yellow-green) OSSD1 (Black) RESET (Note 1, 2) 34 42 L1 L2 L3 KB OUT KB KA M 3 Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) This is a test input (pink) for the SF2B series. 4) This is not equipped on the SF2B series. 5) This is a shield for the SF2B series. Output polarity cannot be set. A2 0V LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS (Orange) Synchronization + +24 V DC (Orange / Black) Synchronization – Output polarity Emission halt Auxiliary output Interlock setting input setting wire input / Reset input (Yellow-green / (Pale purple) (Note 4) Black) Open +V (Brown) (Shield) (Note 5) (Pink) (Note 3) Receiver Cable color: Gray with black line Cable color: Gray +V (Brown) (Orange) Synchronization + 0V (Blue) Emitter INTER_LOCK FAULT 14 24 AUX KA, KB: Magnet contactor KA N 34 42 L1 L2 L3 KB KB KA M 3 Notes: 1) T  he above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) This is a test input (pink) for the SF2B series. 4) This is not equipped on the SF2B series. 5) This is a shield for the SF2B series. Output polarity cannot be set. PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Terminal arrangement diagram A1 A2 S1 S2 S3 S4 AUX X1 X2 X3 13 14 23 24 33 34 41 42 Terminal Function When connecting the SF-C13 to the light curtains, make sure to use a discrete wire connection cable. Refer to the SF4B series and SF2B series for details. SFB-CCB□(-MU), SF2B-CCB□, SFB-CC□(-MU) A1 +24 V DC A2 0V S1 to S4 Light curtain control output (OSSD) input terminal AUX Semiconductor auxiliary output X1 Reset output terminal X2 Reset input terminal (Manual) X3 Reset input terminal (Automatic) 13-14, 23-24, 33-34 Safety output (NO contact × 3) SF-C10 41-42 Auxiliary output (NC contact × 1) SF-CL1T264T Use a separate terminal block to carry out wiring for light curtains that cannot be connected to the SF-C13. Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF-AC 711 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Exclusive Control Unit for Light Curtain LIGHT CURTAIN WIRING DIAGRAMS Wiring diagram of SF-C14EX(-01) and SF4B series (Control category 4) WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS • Set the output polarity selection switch to the PNP side and ground the 0 V line. Emergency stop switch +24 V DC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS (Note 1) KA RESET KB (Note 2) (Note 1) KC RESET KD (Note 2) PLC etc. KE RESET KF (Note 2) A1 S11 S12 S21 S22 X11 X12 X13 X21 X22 X23 X31 X32 AUX1 AUX2 AUX3 AUX4 IE+ IE– IR+ IR– Receiver side NPN Output polarity connector selection switch PNP SF-C14EX(-01) control circuit Muting sensor 1 (PNP output type) Muting sensor 2 (NPN output type) Override input TEST Muting lamp output 1 3.6 to 30 W 0V Muting lamp output 2 3.6 to 30 W KA to KF: Force-guided relay or magnet contactors. Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X12 and X22, and connect them to X13 and X23 as shown by the dotted lines. In this case, a reset (RESET) button is not needed. Terminals X31 to X32 are for manual reset only. 2) Use a momentary-type switch for the reset (RESET) button. For NPN output (plus ground) • Set the output polarity selection switch to the NPN side and ground the + side of the power supply input. Emergency stop switch (Note 1) KA RESET KB (Note 2) (Note 1) KC RESET KD (Note 2) KE RESET KF (Note 2) PLC etc. F.G. A1 S11 S12 S21 S22 X11 X12 X13 X21 X22 X23 X31 X32 AUX1 AUX2 AUX3 AUX4 IE+ IE– IR+ IR– Receiver side NPN Output polarity connector selection switch PNP Emitter side connector SF-C14EX(-01) control circuit Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF-C10 SF-CL1T264T SF-AC Notes: 1) The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X12 and X22, and connect them to X13 and X23 as shown by the dotted lines. In this case, a reset (RESET) button is not needed. Terminals X31 to X32 are for manual reset only. 2) Use a momentary-type switch for the reset (RESET) button. A2 S3+ S3 S3– S4+ S4 S4– T1 T2 O1 O2 L1+ L1– L2+ L2– 14 24 34 44 54 64 KB KD KF +V OUT 0V +V OUT 0V 0V KA Muting sensor 1 (PNP output type) KC TEST Muting sensor 2 (NPN output type) Override input Terminal Light Curtains • If the emergency stop switch is not used, short-circuit between the terminals S11 to S12 and S21 to S22 directly. A2 S3+ S3 S3– S4+ S4 S4– T1 T2 O1 O2 L1+ L1– L2+ L2– 14 24 34 44 54 64 KB KD KF +V OUT 0V +V OUT 0V 0V F.G. KA KC KE Muting lamp output 1 3.6 to 30 W Muting lamp output 2 3.6 to 30 W KE 24 V KA to KF: Force-guided relay or magnet contactors. Terminal arrangement diagram Selection Guide S3+ S3 S3– S4+ S4 S4– Emitter side connector +24 V DC PLC • When connecting the SF-C14EX to the light curtains, make sure to use the following connecting cable. SFB-CB05-EX (Cable length: 0.5 m 1.640 ft) SFB-CB5-EX (Cable length: 5 m 16.404 ft) SFB-CB10-EX (Cable length: 10 m 32.808 ft) • If the NO (Normally Open) contact switch is used as a muting sensor, wire it as shown in the figure below. For PNP output (minus ground) SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS SF-C10 SERIES Pin layout for light curtain connectors Function Terminal Function 14 Safety output 1, Light received / Light S11 Emergency stop 24 interrupted output of the light curtain S12 contact input 2 NC input 34 Safety output 2, Light curtain output S21 Between S11 and S12 44 including the muting function S22 Between S21 and S22 S3– S4+ S4 S4– T1 T2 O1 O2 (PNP output type) S3+, S3–: Power supply S3: Sensor output Muting sensor input 2 (NPN output type) S4+, S4–: Power supply S4: Sensor output Test input terminal Open: Test mode Short-circuit: Normal operation Override input terminal Open: Invalid Short-circuit: Valid 3 Interference Interference prevention wire – prevention wire – 4 Auxiliary output 5 Synchronization Synchronization wire + wire + X31 Safety output 3 reset input X32 X31 - X32: Manual reset 6 Synchronization Synchronization wire – wire – AUX1 Auxiliary output 1, Muting output 7 0V 0V AUX2 Auxiliary output 2, Override output 8 Shielded wire Shielded wire X21 Safety output 2 reset input X22 X21 - X22: Manual reset X23 X21 - X23: Auto-reset AUX3 Auxiliary output 3, Blown lamp output AUX4 Auxiliary output 4, Light curtain auxiliary output IR+ Interference prevention terminal, Receiver side + 0V Receiver side connector +24 V DC L2+ Muting lamp output L2– 2 A2 Emitter side connector 2 IE+ Interference prevention terminal, Emitter side + +24 V DC Connector pin No. 8 Interference Interference prevention wire + prevention wire + L1+ Muting lamp output L1– 1 A1 1 1 54 Safety output 3 X11 Safety output 1 reset input 64 Emergency stop output X12 X11 - X12: Manual reset S3+ Muting sensor input 1 X13 X11 - X13: Auto-reset S3 2 3 IE– Interference prevention terminal, Emitter side – IR– Interference prevention terminal, Receiver side – 7 4 6 5 +24 V DC Not used Exclusive Control Unit for Light Curtain PRECAUTIONS FOR PROPER USE Part description and function [SF-C14EX(-01)] 1 Emitter side connector 2 Receiver side connector 15 Interlock 1 indicator (INTER LOCK1)(Yellow) 8 Safety output 1 indicator (OUT1)(Green) 3 Digital indicator (Red) 4 Power indicator (Ui) (Green) 11 Output 5 Muting sensor 1 indicator (MU1)(Orange) 13 Auxiliary 6 Test input indicator (TEST)(Yellow) 16 Interlock 7 9 Muting sensor 2 indicator (MU2)(Orange) Safety output 2 indicator (OUT2)(Green) 10 Safety output 3 indicator (OUT3)(Green) No. Description 12 Auxiliary output 1 indicator (AUX1)(Orange) polarity selection switch Output waveform (Safety output ON) [SF-C14EX(-01)] • When safety output is ON, self-diagnosis of the output circuit is carried out, so that the output transistor will periodically turn OFF. (OFF pulse width: 100 µs or less) When the OFF signal is fed back, the receiver judges the output circuit as normal. When the OFF signal is not fed back, the receiver judges either the output circuit or wiring as error, and the safety output maintains OFF status. Since the OFF signal of SF-C14EX(-01) might cause malfunction, perform the connecting paying attention to the input response time of the machine to be connected to SF-C14EX(-01). 2 indicator (INTER LOCK2)(Yellow) 14 Auxiliary output 3 indicator (AUX3)(Orange) 3 indicator (INTER LOCK3)(Yellow) Function 1 Emitter side connector The emitter of SF4B series is connected. 2 Receiver side connector The receiver of SF4B series is connected. 3 Digital indicator (Red) Lights up or blinks when there is a problem. Lights up when blanking function is enabled. 4 Power indicator (Ui) (Green) Lights up when the power is ON. 5 Lights up when test input is enabled. Blinks while Test input indicator (TEST) (Yellow) communication with SFB-HC handy-controller is in progress. (Excluding SF-C14EX-01) 6 Muting sensor 1 indicator (MU1) (Orange) Lights up when muting sensor 1 is ON. 7 Muting sensor 2 indicator (MU2) (Orange) Lights up when muting sensor 2 is ON. 8 Safety output 1 indicator (OUT1) (Green) Lights up when safety output 1 is ON. 9 Safety output 2 indicator (OUT2) (Green) Lights up when safety output 2 is ON. 10 Safety output 3 indicator (OUT3) (Green) Lights up when safety output 3 is ON. 11 Output polarity selection switch PNP (minus ground) or NPN (plus ground) can be selected. The factory setting is PNP (minus ground). 12 Auxiliary output 1 indicator (AUX1) (Orange) Lights up when auxiliary output 1 is ON. 13 Auxiliary output 2 indicator (AUX2) (Orange) Lights up when auxiliary output 2 is ON. 14 Auxiliary output 3 indicator (AUX3) (Orange) Lights up when auxiliary output 3 is ON. 15 Interlock 1 indicator (INTER LOCK1) (Yellow) Lights up when interlock 1 is ON. 16 Interlock 2 indicator (INTER LOCK2) (Yellow) Lights up when interlock 2 is ON. 17 Interlock 3 indicator (INTER LOCK3) (Yellow) Lights up when interlock 3 is ON. Wiring • The following solid wire and twisted wires (lead wire) are recommended. SF-C11 Power supply and output line connector: 0.2 to 2.5mm2 (AWG24 to 12) Signal line connector: 0.2 to 1.5mm2 (AWG24 to 16) SF-C13 Single wire: ø0.4 to ø1.2 mm ø0.016 to ø0.047 in (AWG26 to 16) Twisted wire (lead wire): 0.3 to 1.25mm2 (AWG22 to 16) SF-C14EX(-01) Power supply line connector (A1, A2): 0.2 to 2.5mm2 (AWG24 to 12) Other connectors: 0.2 to 1.5mm2 (AWG24 to 16) 712 Refer to p.1501 for general precautions. output 2 indicator (AUX2)(Orange) 17 Interlock SF-C10 SERIES FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Time chart [SF-C14EX(-01)] Normal operation SENSOR OPTIONS • The diagram shows operation with safety outputs 1 and 2 in manual-reset mode. SIMPLE WIRE-SAVING UNITS Light received Light interrupted Invalid Emergency stop Valid Muting sensor 1 ON OFF Muting sensor 2 ON OFF ON Reset input 1 OFF ON Reset input 2 OFF ON Reset input 3 OFF Safety output 1 ON OFF (14, 24) Safety output 2 ON OFF (34, 44) Safety output 3 ON OFF (54, 64) Auxiliary output 1 ON (Muting output) OFF Auxiliary output 4 ON (Auxiliary output of light curtain) OFF ON Muting lamp OFF output 1 / 2 Light curtain WIRE-SAVING SYSTEMS MEASUREMENT SENSORS 0 to 3 sec. 0 to 3 sec. • The diagram above is the timing chart of SF-C14EX(-01) in normal operation. • In normal operation, auxiliary output 2 (override output) is maintained in the ON state. • In normal operation, auxiliary output 3 (muting lamp output) is maintained in the ON state. STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF-C10 SF-CL1T264T SF-AC 713 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF-C10 SF-CL1T264T SF-AC Exclusive Control Unit for Light Curtain SF-C10 SERIES PRECAUTIONS FOR PROPER USE Time chart [SF-C14EX(-01)] Test input, Override input • The diagram shows operation with safety outputs 1 and 2 in auto-reset mode. Open Short-circuited Override input Valid Invalid Light received Light curtain Light interrupted Muting sensor ON 1/2 OFF Safety output 1 ON (14, 24) OFF Safety output 2 ON (34, 44) OFF Auxiliary output 1 ON (Muting output) OFF Auxiliary output 2 ON (Override output) OFF ON Muting lamp OFF output 1 / 2 Test input 0 to 1 sec. 3 sec. Override input time: Max. 60 sec. • Safety outputs 1 and 2 are OFF during test input. • The override function becomes valid when all the conditions listed below are satisfied: • An incandescent lamp with 3.6 to 30 W is at least connected to either muting lamp output 1 or 2. • The signal is input to either muting sensor 1 or 2. • The override input terminal O1 and O2 is short-circuited and the test input terminal T1 / T2 is opened within 1 sec. (3 sec. continuously) If one of the three conditions above becomes invalid or the timing exceeds 60 sec., the override function becomes invalid. Blown lamp output • The diagram shows operation with safety outputs 1 and 2 in auto-reset mode. Light received Light interrupted ON Muting OFF sensor 1 ON Muting sensor 2 OFF Safety output 2 ON OFF (34, 44) Auxiliary output 1 ON (Muting output) OFF Auxiliary output 3 ON (Blown lamp output) OFF ON Muting lamp OFF output 1 ON Muting lamp OFF output 2 Light curtain Blown lamp Blown lamp Blown lamp • The lamps are monitored during muting state, and if either of them breaks, auxiliary output 3 is turned OFF. If only one lamp breaks, the muting state is maintained, however, if both lamps break, the muting state is canceled immediately. Others • When connecting this product to a product other than the connectable input device, the system does not conform to the control category 4 based on ISO 13849-1:1999(EN 954-1, JIS B 9705-1). • The power supply unit of SF-C10 series uses the electronic fuse which does not require any replacement. • When the electronic fuse trips, turn off the power supply and eliminate the cause for the overcurrent. After that, turn the power back on. • The electronic fuse is not meant to be used for equipment that is operated continuously. Note that the specification may not be satisfied by continuous operation. Refer to p.1501 for general precautions. • Make sure to carry out the wiring in the power supply off condition. • Wrong wiring will damage the product. • Verify that the supply voltage variation is within the rating. Note that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the unit may get burnt or damaged. • The DC power supply unit must satisfy the conditions given below: 1) P  ower supply unit authorized in the region where this device is to be used. 2) P  ower supply unit conforming to EMC Directive and Lowvoltage Directive (In case CE conformity is required.) 3) P  ower supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less. 4) T  he frame ground (F.G.) terminal must be connected to ground when using a commercially available switching regulator. 5) P  ower supply unit with an output holding time of 20 ms or more. 6) U  se an isolation transformer for the DC power supply unit. 7) If surges are likely to occur, take countermeasures such as connecting a surge absorber to the origin of the surge. 8) P  ower supply unit corresponding to CLASS 2 (In case UL / c UL conformity is required.) As provided in IEC 60536 (CLASS: Protection against Electric Shook), this power supply should require no ground earth and satisfy the insulation distance by double insulation or reinforced insulation. If the power supply conforms to Low-voltage Directive and has an output of 100 VA or less, it can be used as a suitable product. • Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. • This product is not dust-proof / splash proof. Be sure to put this product into a control box having IP54 construction. (Excluding SF-C12) • Avoid dust, dirt and steam. • Take care that the product does not come in direct contact with oil, grease, or organic solvents, such as, thinner, etc. • Note that this equipment is applicable only in the control circuit grounded in accordance with IEC 60204-1 and JIS B 9960-1, or in the control circuit in which the insulation monitor unit (ground fault detection unit) is included. • This unit is suitable for indoor use only. • The seal as shown in the drawing on the below is stuck to the engagement point of unit. If the seal is peeled off or broken, SF-C10 series will not be certified as “Safety equipment” and will not be covered by our guarantee. Do not open! If this seal is removed or damaged, the units are not recognized as safety product. Exclusive Control Unit for Light Curtain DIMENSIONS (Unit: mm in) Control unit 4 0.157 46 1.811 23 0.906 13 0.512 40 1.575 25 0.984 35 1.378 67.3 2.650 48.8 1.921 SF-C12 Control unit 2-ø6 ø0.236 2-ø10 ø0.394 6 7 0.276 0.236 6.5 0.256 80 3.150 100 3.937 ( 130 5.118 28 1.102 114 4.488 8 0.315 6 0.236 10 0.394 21 0.827 8 0.315 11.5 0.453 Receiver side connector 67.5 2.657 6.5 0.256 ( ) Suitable for 35 mm 1.378 in width DIN rail MICRO PHOTOELECTRIC SENSORS AREA SENSORS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS 36.5 1.437 36.5 34.2 1.437 1.346 LASER SENSORS LIGHT CURTAINS / SAFETY COMPONENTS 81.4 135 3.205 5.315 6 19.5 0.236 0.768 22 24.5 30.5 0.866 0.965 1.201 ) FIBER SENSORS PHOTOELECTRIC SENSORS 127 5.000 80 3.150 30 1.181 Emitter side connector 3 × 6 = 18 3 × 0.236 = 0.709 130 5.118 714 The CAD data in the dimensions can be downloaded from our website. SF-C11 54.1 2.130 SF-C10 SERIES WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES SF-C13 Control unit SF-C14EX(-01) Application expansion unit LASER MARKERS PLC 6.75 0.266 4 0.157 5 0.197 6 0.236 34.5 1.358 35 1.378 67.3 2.650 4 0.157 3 × 5 = 15 3 × 0.197 = 0.591 130 5.118 54.1 2.130 40 1.575 Emitter side connector 25 34.1 0.984 1.343 35 1.378 91.6 3.606 13 0.512 67.3 2.650 6.5 0.256 80 3.150 80.8 3.181 13 0.512 Suitable for 35 mm 1.378 in width DIN rail 22.5 0.886 5 0.197 10 0.394 HUMAN MACHINE INTERFACES Receiver side connector 31.1 1.224 11 0.433 130 5.118 10 0.394 13.5 0.531 46 1.811 38.4 1.512 18 18.4 0.709 0.724 23 0.906 80 3.150 99 3.898 Suitable for 35 mm 1.378 in width DIN rail 6.5 0.256 ( ) ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF-C10 SF-CL1T264T SF-AC
SF-C14EX 价格&库存

很抱歉,暂时无法提供与“SF-C14EX”相匹配的价格&库存,您可以联系我们找货

免费人工找货