0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SF2B-A28SL

SF2B-A28SL

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    LITE CURTAIN ARM/FT 1112MM

  • 数据手册
  • 价格&库存
SF2B-A28SL 数据手册
609 FIBER SENSORS Light Curtain Type 2 SF2B SERIES Ver.2 Related Information ■■General terms and conditions.............. F-7   Glossary of terms / General precautions...P.1455~ / P.1458~ ■■Sensor selection guide...................P.497~ ■■SF-C10.............................................. P.703~ LASER SENSORS PHOTOELECTRIC SENSORS Conforming to Machine & EMC Directive MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Conforming to Conforming to Certified Certified* (SF4B-□-03only) Protection Conventional: IP65 (IEC) Ver.2: IP65 / IP67 (IEC, JIS) WIRE-SAVING SYSTEMS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS Conforming to 4584 (Excluding SF4B-□-03) Upgraded to version 2.0 from January 2009 shipments. SIMPLE WIRE-SAVING UNITS LASER MARKERS OSHA/ANSI Upgrade Guide SENSOR OPTIONS STATIC ELECTRICITY PREVENTION DEVICES OSHAListing / ANSI Approved Conforming to Machine & EMC Directive PARTICULAR USE SENSORS MEASUREMENT SENSORS Listing diagnosis Control Category 2 PLc SIL1 panasonic.net/id/pidsx/global Self-diagnosis Test input Interference PNP output type available prevention Type 2 safety solution International regulations for safety measures at reasonable cost Protective structure IP67* is achieved with a seamless structure that has reduced seams *Version 2.0 or later The inner unit is protected by a cylindrical inner case. The seams of unit and lens surfaces have been greatly reduced, so that particles of oil mists and dust are prevented from getting in. End unit Internal unit MACHINE VISION SYSTEMS UV CURING SYSTEMS Protective case Inner case The photograph shows a cut-away model. Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C SF4C SF2C SF4B SF2B BSF4-AH80 Extensive range of variations available with sensing widths from 168 mm to 1,912 mm 6.614 in to 75.275 in Two types are available for different minimum sensing object sizes. Hand protection type SF2B-H□ Minimum sensing object ø27 mm ø1.063 in 20 mm 0.787 in beam pitch Arm / Foot protection type SF2B-A□ Minimum sensing object ø47 mm ø1.850 in 40 mm 1.575 in beam pitch Light Curtain Type 2 SF2B SERIES Ver.2 Series connection of up to three sets is possible Sub-sensors for series connection (optional) can be used to connect up to three sets of light curtains (up to a total of 128 beam channels maximum; however, the SF2B-A□ allows up to 96 beam channels when two sets are connected, and up to 64 beam channels when three sets are connected). • The light curtains and the subsensors for serial connection (optional) have different models. When connecting light curtains in series, be sure to use the sub-sensors for serial connection and serial connection cables which are sold separately. • The SF2B-H8-□ and SF2B-A4-□ cannot be connected in series. For details, refer to “Series connection” of “PRECAUTIONS FOR PROPER USE”. Sub-sensor for series connection only SF2B-□SL (Optional) Sub-sensor for series connection only SF2B-□SL (Optional) Cables for series connection SF2B-CSL□ (Optional) Hand protection type and Arm / Foot protection type can be used together. Arm / Foot protection type Hand protection type 610 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Light curtain SF2B-□ SENSOR OPTIONS “ZERO” dead zone. Unit length = protective height, so mounting is possible with no dead zone SIMPLE WIRE-SAVING UNITS The sensing area contains no dead spaces. Even with series connections, there are no dangerous openings at the interfaces between light curtains. This makes a simpler and more compact installation possible. WIRE-SAVING SYSTEMS SF2B MEASUREMENT SENSORS Previous model “ZERO” dead zone when using series mounting Dead zone when using series mounting Gaps occurred at connecting point It used to be necessary to install a cover or offset the light curtain in order to eliminate gaps. LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Dead zone “ZERO” dead zone when using L-shaped mounting STATIC ELECTRICITY PREVENTION DEVICES Overlapped mounting when using L-shaped mounting Complex installation Increased design and installation man-hours FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Overlapped mounting Note: The SF2B-H8-□ and SF2B-A4-□ cannot connected in series. For details, refer to “PRECAUTIONS FOR PROPER USE (p.626~)”. Mutual interference is reduced without need for interference prevention lines Reducing the number of malfunctions caused by extraneous light The scan timing of the light curtain is automatically shifted in order to reduce mutual interference. A double scanning method and retry processing are new functions exclusive to that are effective in eliminating the effect of momentary extraneous light from peripheral equipment. Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C SF2B SF2B SF4C SF2C SF4B Irregular reflected light SF2B BSF4-AH80 Extraneous light (flasher) Extraneous light (Obstacle detecting sensor) 611 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Light Curtain Type 2 SF2B SERIES Ver.2 Equipped with a digital error indicator so that error details can be understood at a glance Beam-axis alignment indicators show the incident light position at a glance The system constantly checks the light curtain for problems such as incorrect cable wiring, disconnection, short-circuits, internal circuit problems, and incoming light problems. If a problem should occur, details of the error appear on the digital display. Therefore, smooth support is possible if problems occur at startup and during maintenance operations, even if assistance is given via telephone. Beam-axis alignment indicators display the beam channels of the light curtain in four blocks. The blocks where the beam axes match will light up in red in turn. When all the beam axes receive light, all the LEDs light up green. Furthermore, a stability indicator (STB.) lights up when there is sufficient incoming light. Normal operation Beam-axis alignment indicator Breaking out error A B PARTICULAR USE SENSORS C SENSOR OPTIONS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Adapter cables and adapter mounting brackets are available so that previous peripheral devices for light curtains can still be used The light curtain SF2-A / SF2-N series (discontinued model), area sensor NA40 series, and SF1-N series (discontinued model) can be replaced with the SF2B series using the current mounting holes and connection cables. Selectable safety circuits The light curtain unit has a built-in monitoring function for external devices (such as fused relay monitoring). This supports the construction of light curtain peripheral safety circuits which do not use a safety relay unit, and contributes to reduced costs and a more compact control panel. In addition, a connectable control unit is used, so that a safety circuit that is easy to construct and easy to install can be selected. FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Utilizing light curtain functions Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C SF4C SF2C SF4B SF2B D * When using the SF2B-CB05-B adapter cable, the beam axis alignment indicator of emitter cannot be used. Digital error indicator Utilizing connectable control unit Reduced component costs WIRE-SAVING SYSTEMS Beam-axis alignment indicator Less processing SIMPLE WIRE-SAVING UNITS • Recommended Recommendedsafety safety relays relays Monitor SF2B series Safety relay, etc. Contactor, etc. Uses external device monitoring function Motor, etc. Panasonic Corporation Model No.: SF series ●Safety relay Panasonic Electric Woks SUNX Co.,Ltd. SF relay Note: Construct a separate reset input circuit. Note: Note:Contact Contactthe themanufacturers manufacturers forfordetails detailsononthe the recommendedproducts. products. recommended Reset input Monitor SF2B series Uses SF-C11 connectable control unit Contactor, etc. Motor, etc. Significant cost reduction is achieved by using corner mirror By using a single corner mirror, light curtain and peripheral safety circuit for one set are eliminated. Enables significant cost reduction and savings on wiring. The control category is unchanged. BSF4-AH80 When setting up the light curtains in the L-shape or U-shape, usually two or three sets of the light curtains are required. However, using the corner mirror to reflect the laser light allows only one set of the light curtains to be set up at the L-shape or U-shape. Corner mirror RF-SFBH-□ Light Curtain Type 2 SF2B SERIES Ver.2 PRODUCT CONFIGURATION 612 FIBER SENSORS LASER SENSORS 6 Sub-sensor for series connection only / p.615 PHOTOELECTRIC SENSORS (Optional, use for connect in series) • Mounting bracket and mating cable are optional. • When using series connection, sub-sensors for serial connection are needed in addition to the light curtains. 5 Cable for series connection / p.614 (Optional, use for connect in series) * 1 Light curtain / p.612 * 1 , 2 and 3 are required. 4 Extension cable / p.614 (Optional, use for cable extension) Hand protection type Arm / Foot protection type Min. sensing object ø47 mm ø1.850 in (40 mm 1.575 in beam pitch) Min. sensing object ø27 mm ø1.063 in (20 mm 0.787 in beam pitch) Operating range (Note 1) Appearance 6 mm 0.236 in (Note 3) Protective height 0.2 to 13 m 0.656 to 42.651 ft Beam pitch 6 mm 20 mm 0.787 in 0.236 in Beam channel No. INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS 1 Light curtains Mounting bracket and bottom cap cable are not supplied with the light curtain. Be sure to order them separately. Beam channel No. LIGHT CURTAINS / SAFETY COMPONENTS PARTICULAR USE SENSORS ORDER GUIDE Type AREA SENSORS PRESSURE / FLOW SENSORS * 3 Bottom cap cable (Optional) / p.614 * 2 Mounting bracket (Optional) / p.613 MICRO PHOTOELECTRIC SENSORS When using the adapter cable SF2B-CB05-B: 0.2 to 5 m 0.656 to 16.404 ft 6 mm 0.236 in (Note 3) Protective height Beam pitch 40 mm 1.575 in 26 mm 1.024 in 0.2 to 13 m 0.656 to 42.651 ft When using the adapter cable SF2B-CB05-B: 0.2 to 5 m 0.656 to 16.404 ft Model No. (Note 5) NPN output type PNP output type SF2B-H8-N (Note 2) SF2B-H12-N SF2B-H16-N SF2B-H20-N SF2B-H24-N SF2B-H28-N SF2B-H32-N SF2B-H36-N SF2B-H40-N SF2B-H48-N SF2B-H56-N SF2B-H64-N SF2B-H72-N SF2B-H80-N SF2B-H88-N SF2B-H96-N SF2B-A4-N (Note 2) SF2B-A6-N SF2B-A8-N SF2B-A10-N SF2B-A12-N SF2B-A14-N SF2B-A16-N SF2B-A18-N SF2B-A20-N SF2B-A24-N SF2B-A28-N SF2B-A32-N SF2B-A36-N SF2B-A40-N SF2B-A44-N SF2B-A48-N SF2B-H8-P (Note 2) SF2B-H12-P SF2B-H16-P SF2B-H20-P SF2B-H24-P SF2B-H28-P SF2B-H32-P SF2B-H36-P SF2B-H40-P SF2B-H48-P SF2B-H56-P SF2B-H64-P SF2B-H72-P SF2B-H80-P SF2B-H88-P SF2B-H96-P SF2B-A4-P (Note 2) SF2B-A6-P SF2B-A8-P SF2B-A10-P SF2B-A12-P SF2B-A14-P SF2B-A16-P SF2B-A18-P SF2B-A20-P SF2B-A24-P SF2B-A28-P SF2B-A32-P SF2B-A36-P SF2B-A40-P SF2B-A44-P SF2B-A48-P Number of beam channels Protective height (mm in) (Note 4) 8 168 6.614 12 232 9.134 16 312 12.283 20 392 15.433 24 472 18.583 28 552 21.732 32 632 24.882 36 712 28.031 40 792 31.181 48 952 37.480 56 1,112 43.779 64 1,272 50.079 72 1,432 56.378 80 1,592 62.677 88 1,752 68.976 96 1,912 75.275 4 168 6.614 6 232 9.134 SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 8 312 12.283 10 392 15.433 12 472 18.583 14 552 21.732 Light Curtains 16 632 24.882 18 712 28.031 Safety Components 20 792 31.181 24 952 37.480 28 1,112 43.779 32 1,272 50.079 36 1,432 56.378 SF4B-C 40 1,592 62.677 SF4C 44 1,752 68.976 48 1,912 75.275 SF2C Notes: 1) The “operating range” is the possible setting distance between the emitter and the receiver. 2) The SF2B-H8-□ and SF2B-A4-□ cannot be connected in series Actual operating Receiver cannot be because they do not include a connector for series connection. placed in this range 0.2 m range of the sensor Refer to “PRECAUTIONS FOR PROPER USE (p.626~)” for 0.656 ft Setting range of details. the receiver 3) The distance between the tip of the light curtain and the last beam axis of the SF2B-H8-□ and SF2B-A4-□ is 22 mm 0.866 in. 4) Refer to “Definition of light curtain and area sensor sensing heights (p.727)” for details of the protective height. E theEMITTER 5) Models which have an “ E EMITTER ” symbol in model No. on the Receiver Emitter name plate are emitters, and those with a “ D RECEIVER ” symbol are D RECEIVER receivers. Selection Guide Optical Touch Switch Control Units Definition of Sensing Heights SF4B SF2B 13 m 42.651 ft When using the SF2B-CB05-B: 5 m 16.404 ft Receiver BSF4-AH80 613 Light Curtain Type 2 ORDER GUIDE FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS SF2B SERIES Ver.2 2 Mounting brackets Mounting bracket is not supplied with the light curtain. Be sure to order it separately. • MS-SF2B-1 Designation Appearance Model No. AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS Standard mounting bracket Standard mounting bracket Description MS-SF2B-1 Used to mount the light curtain on the rear surface and side surface 4 pcs. per set for emitter and receiver MS-SF2B-3 Mounting of the light curtain is possible so that the mounting bracket does not project past the protective height (light curtain length). 4 pcs. per set for emitter and receiver Standard mounting bracket MS-SF2B-1 Hexagon-socket-head bolts [M3 (length 5 mm 0.197 in)] for ( Accessory MS-SF2B-1 ) Light curtain PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Dead zoneless mounting bracket SIMPLE WIRE-SAVING UNITS For SF2-A / SF2-N STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS For rear and side mounting MEASUREMENT SENSORS MS-SF2B-5 UV CURING SYSTEMS For NA40 Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C For SF1-N For rear mounting MS-SF2B-4 For side mounting MACHINE VISION SYSTEMS For SF1-N / NA40 MS-SF2B-6 MS-SF2B-7 SF4B Used when replacing units in the SF2-A / SF2-N series. (discontinude mode) 4 pcs. per set for emitter and receiver Used when replacing units in the SF1-N (discontinude mode) / NA40 series which are using the MS-SF1-1 / MS-NA40-1 sensor mounting brackets.(Note) 4 pcs. per set for emitter and receiver Used when replacing units in the NA40 series which are side mounted (direct mounted).(Note) 4 pcs. per set for emitter and receiver Dead zoneless mounting bracket MS-SF2B-3 Light curtain Sensing surface Four bracket set Six spacers for the intermediate supporting bracket and twelve M5 (length 8 mm 0.315 in) hexagon-socket-head bolts are attached. • MS-SF2B-5 Adapter mounting brackets MS-SF2B-5 • MS-SF2B-6 Hexagon-socket-head bolt [M3 (length 5 mm 0.197 in)] Adapter mounting bracket MS-SF2B-6 Used when replacing units in the SF1-N series (discontinude mode) which are side mounted (discontinude mode). 4 pcs. per set for emitter and receiver • MS-SF2B-7 for ( Accessory MS-SF2B-6 ) Sensing surface Four bracket set M3 (length 5 mm 0.197 in) hexagon-socket-head bolts are attached. 8 pcs. for light curtain mounting; 8 pcs. for beam axis adjustment Sensing surface Four bracket set Eight M3 (length 5 mm 0.197 in) hexagon-sokethead bolts are attached. Adapter mounting bracket MS-SF2B-4 Hexagon-socket-head bolt [M3 (length 5 mm 0.197 in)] for ( Accessory MS-SF2B-4 ) Adapter mounting bracket MS-SF2B-7 Light curtain Sensing surface • MS-SF2B-4 Hexagon-socket-head bolt [M3 (length 5 mm 0.197 in)] Accessory for MS-SF2B-7 SF2B BSF4-AH80 Hexagon-socket-head bolts [M3 (length 5 mm 0.197 in)] for ( Accessory MS-SF2B-5 ) Note: S  F1-N-compatible mounting bracket can also be used for SF1-S / SF1-A series products that are discontinued. The NA40-compatible mounting bracket can also be used for NA40-S / NA40-B series products that are discontinued. SF4C SF2C M3 (length 5 mm 0.197 in) hexagon-socket-head bolts are attached. 8 pcs. for light curtain mounting; 8 pcs. for beam axis adjustment Light curtain For side mounting FA COMPONENTS Adapter mounting brackets PLC ENERGY CONSUMPTION VISUALIZATION COMPONENTS Four bracket set • MS-SF2B-3 WIRE-SAVING SYSTEMS HUMAN MACHINE INTERFACES Sensing surface Light curtain Light curtain Sensing surface Adapter mounting bracket MS-SF2B-7 Four bracket set Hexagon-socket-head bolt Eight M3 (length 5 mm 0.197 in) hexagon-soket- [M3 (length 5 mm 0.197 in)] head bolts are attached. Sensing surface Four bracket set Eight M3 (length 5 mm 0.197 in) hexagon-sockethead bolts are attached. Light Curtain Type 2 SF2B SERIES Ver.2 614 ORDER GUIDE 3 4 FIBER SENSORS 5 Bottom cap cable / Extension cable / Cables for series connection Mating cable is not supplied with the light curtain. Be sure to order it separately. Type Appearance Model No. Bottom cap cable Discrete wire SF2B-CCB3 SF2B-CCB7 SF2B-CCB10 SF2B-CCB15 Discrete wire With connectors on both ends For receiver For emitter SFB-CC10 SFB-CCJ10E SFB-CCJ10D For SF2-A / SF2-N For SF1‑N / NA40 Extension cable Adapter cable (Bottom cap cable) 3 * SFB-CC3 SF2B-CB05-A SF2B-CB05-B 5 Cable length: 3 m 9.843 ft Net weight: 370 g approx. (2 cables) Cable length: 7 m 22.966 ft Net weight: 820 g approx. (2 cables) Cable length: 10 m 32.808 ft Net weight: 1,160 g approx. (2 cables) Cable length: 15 m 49.213 ft Net weight: 1,720 g approx. (2 cables) *U  sed in conjunction with subsensor for serial connection only. Used for connecting to the light curtain and to other cables or the SF-C13 control unit. Two cables per set for emitter and receiver Cable outer diameter: ø6 mm ø0.236 in Cable color: Gray (for emitter) Gray with black line (for receiver) The min. bending radius: R6 mm R0.236 in Cable length: 0.5 m 1.640 ft Used for connecting to the light curtain and to an Net weight: 95 g approx. (2 cables) extension cable or the SF-C11 control unit. Two cables per set for emitter and receiver Cable length: 5 m 16.404 ft Cable outer diameter: ø6 mm ø0.236 in Net weight: 620 g approx. (2 cables) Connector outer diameter: ø14 mm ø0.551 in max. Cable color: Gray (for emitter), Gray with black line (for receiver) Cable length: 10 m 32.808 ft Connector color: Gray (for emitter), Black (for receiver) Net weight: 1,200 g approx. (2 cables) The min. bending radius: R6 mm R0.236 in Used for cable extension or connecting to the SF-C13 control unit. Cable length: 3 m 9.843 ft Two cables per set for emitter and receiver Net weight: 380 g approx. (2 cables) Cable outer diameter: ø6 mm ø0.236 in Cable length: 10 m 32.808 ft Connector outer diameter: ø14 mm ø0.551 in max. Net weight: 1,200 g approx. Cable color: Gray (for emitter), Gray with black line (for receiver) (2 cables) The min. bending radius: R6 mm R0.236 in Cable length: 10 m 32.808 ft Used for cable extension or connecting to the SF-C11 control unit. One each for emitter and receiver Net weight: 580 g approx. Cable outer diameter: ø6 mm ø0.236 in (1 cable) Connector outer diameter: ø14 mm ø0.551 in max. Cable length: 10 m 32.808 ft Cable color: Gray (for emitter), Gray with black line (for receiver) Net weight: 600 g approx. Connector color: Gray (for emitter), Black (for receiver) (1 cable) The min. bending radius: R6 mm R0.236 in Cable length: 0.5 m 1.640 ft Net weight: 95 g approx. (2 cables) Cable length: 0.5 m 1.640 ft Net weight: 95 g approx. (2 cables) * Please contact our office for wiring of adapter cables. Cable for series connection 4-core cable SF2B-CB5 SF2B-CB10 4 8-core cable Connector 3 SF2B-CB05 Description SF2B-CSL01 Cable length: 0.1 m 0.328 ft Net weight: 70 g approx. (2 cables) SF2B-CSL05 Cable length: 0.5 m 1.640 ft Net weight: 120 g approx. (2 cables) Used when replacing units in the SF2-A / SF2-N series (discontinude mode). The SF2N-CC□ cable with connector can be used without change, so that replacement with SF2B series units can be done smoothly. Two cables per set for emitter and receiver Cable outer diameter: ø6 mm ø0.236 in Connector outer diameter: ø14 mm ø0.551 in max. Cable color: Gray (for emitter), Gray with black line (for receiver) Connector color: Gray (for emitter), Black (for receiver) The min. bending radius: R6 mm R0.236 in Used when replacing units in the SF1-N (discontinude mode) / NA40 series. The SF1-CC□ / NA40-CC□ cable with connector can be used without change, so that replacement with SF2B series units can be done smoothly. Two cables per set for emitter and receiver Cable outer diameter: ø6 mm ø0.236 in Connector outer diameter: ø14 mm ø0.551 in max. Cable color: Gray (for emitter), Gray with black line (for receiver) Connector color: Gray (for emitter), Black (for receiver) The min. bending radius: R6 mm R0.236 in Use when connecting the sub-sensor for series connection to the light curtain in series. Two cables per set for emitter and receiver (common for emitter and receiver) Cable outer diameter: ø6 mm ø0.236 in Cable color: Gray (common for emitter and receiver) The min. bending radius: R6 mm R0.236 in * Interchangeability function • This function is used for replacing other light curtains or area sensors with these new units. The bottom cap cables and sensor mounting brackets used will vary depending on the models being replaced. Refer to the instruction manual for details on actual wiring and mounting. Models being replaced Adapter cable Adapter mounting bracket Details of changes and points to note • NPN output type: Connect the shielded wire to +V. PNP output type: Connect the shielded wire to 0 V. SF2-A / SF2-N series • Existing SF2N-CC□ connection cables (optional) can be used without change. SF2B-CB05-A MS-SF2B-5 (Discontinued product) • The interference prevention function (parallel connection) cannot be used. • Emitter: Synchronization cable has changed to interference prevention cable.(Note 1) When using the MS-SF1-1: SF1-N series Receiver: Synchronization cable has changed to control output (OSSD 1).(Note 2)(Note 3) SF2B-CB05-B MS-SF2B-4 • Existing SF1-CC□A connection cables (optional) can be used without change. (Discontinued product) For direct mounting: MS-SF2B-7 • The beam axis alignment indicator of emitter cannot be used. • Control output (OSSD 2) is equipped instead of self-diagnosis output.(Note 3) • Emission halt function cannot be used. When using the MS-NA40-1: NA40 series SF2B-CB05-B MS-SF2B-4 • Existing NA40-CC□ connection cables (optional) can be used without change. For direct mounting: MS-SF2B-6 • The ambient temperature for the NA40-CC□ connection cables (optional) is –10 to +50 °C +14 to +122 °F. Notes: 1) Not used in case of simple replacement of the SF1-N series (interference prevention wire is unused), therefore perform wire insulation so that it will not touch other wires. 2) Not used in case of simple replacement of the SF1-N series (non-safety applications), therefore perform wire insulation so that it will not touch other wires. 3) When used in safety applications, both OSSD1 and OSSD2 must be used. LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C SF4C SF2C SF4B SF2B BSF4-AH80 615 Light Curtain Type 2 ORDER GUIDE FIBER SENSORS Type MICRO PHOTOELECTRIC SENSORS AREA SENSORS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Hand protection type LIGHT CURTAINS / SAFETY COMPONENTS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights Arm / Foot protection type PLC Min. sensing object ø27 mm ø1.063 in (20 mm 0.787 in pitch) PHOTOELECTRIC SENSORS The sub-sensors for series connection are PNP / NPN types. Furthermore, they cannot simply 6 Sub-sensor for series connection only be used by themselves. Always be sure to use them in combination with light curtains. Min. sensing object ø47 mm ø1.850 in (40 mm 1.575 in pitch) LASER SENSORS SF2B SERIES Ver.2 Operating range (Note 1) Appearance Model No. (Note 6) Number of Protective height beam (mm in) (Note 4) channels SF2B-H8SL (Note 2) Beam channel No. 6 mm 0.236 in (Note 3) Protective height 0.2 to 13 m 0.656 to 42.651 ft Beam pitch 6 mm 20 mm 0.787 in 0.236 in When using SF2B-CB05-B adapter cable at light curtain: 0.2 to 5 m 0.656 to 16.404 ft 8 168 6.614 SF2B-H12SL 12 232 9.134 SF2B-H16SL 16 312 12.283 SF2B-H20SL 20 392 15.433 SF2B-H24SL 24 472 18.583 SF2B-H28SL 28 552 21.732 SF2B-H32SL 32 632 24.882 SF2B-H36SL 36 712 28.031 SF2B-H40SL 40 792 31.181 SF2B-H48SL 48 952 37.480 SF2B-H56SL 56 1,112 43.779 SF2B-H64SL 64 1,272 50.079 SF2B-H72SL 72 1,432 56.378 SF2B-H80SL 80 1,592 62.677 SF2B-H88SL 88 1,752 68.976 SF2B-H96SL 96 1,912 75.275 SF2B-A4SL (Note 2) 4 168 6.614 SF2B-A6SL 6 232 9.134 SF2B-A8SL Beam channel No. 6 mm 0.236 in (Note 3) Protective height Beam pitch 40 mm 1.575 in 26 mm 1.024 in 0.2 to 13 m 0.656 to 42.651 ft When using SF2B-CB05-B adapter cable at light curtain: 0.2 to 5 m 0.656 to 16.404 ft 8 312 12.283 SF2B-A10SL 10 392 15.433 SF2B-A12SL 12 472 18.583 SF2B-A14SL 14 552 21.732 SF2B-A16SL 16 632 24.882 SF2B-A18SL 18 712 28.031 SF2B-A20SL 20 792 31.181 SF2B-A24SL 24 952 37.480 SF2B-A28SL 28 1,112 43.779 SF2B-A32SL 32 1,272 50.079 SF2B-A36SL 36 1,432 56.378 SF2B-A40SL 40 1,592 62.677 SF2B-A44SL 44 1,752 68.976 SF2B-A48SL 48 1,912 75.275 RECEIVER Spare parts (AccessoriesD for light curtain) Emitter: 20 mA or less Receiver: 35 mA or less Emitter: 30 mA or less Receiver: 45 mA or less Emitter: 30 mA or less Receiver: 55 mA or less Emitter: 40 mA or less Receiver: 65 mA or less Emitter: 45 mA or less Receiver: 85 mA or less Emitter: 50 mA or less Receiver: 105 mA or less Emitter: 60 mA or less Receiver: 125 mA or less Emitter: 15 mA or less Receiver: 20 mA or less Emitter: 15 mA or less Receiver: 25 mA or less Emitter: 20 mA or less Receiver: 30 mA or less Emitter: 20 mA or less Receiver: 35 mA or less Emitter: 25 mA or less Receiver: 40 mA or less Emitter: 25 mA or less Receiver: 50 mA or less Emitter: 30 mA or less Receiver: 60 mA or less Emitter: 35 mA or less Receiver: 70 mA or less Appearance Intermediate supporting bracket Model No. Description MS-SF2B-2 Used to mount the light curtain on the intermediate position. Mounting is possible behind or at the side of the light curtain. SF4B-C SF4C SF4B Emitter: 20 mA or less Receiver: 25 mA or less Notes: 1) The “operating range” is the possible setting distance between the emitter and the receiver. 2) The SF2B-H8SL and SF2B-A4SL do not include a connector for series connection. Therefore, when connecting 3 sets in series, the sub-sensor can be used only for the third set. Refer to “PRECAUTIONS FOR PROPER USE (p.626~)” for details. 3) The distance between the tip of the light curtain and the top beam axis of the SF2B-H8SL and SF2B-A4SL is 22 mm 0.866 in. 4) Refer to “Definition of light curtain and area sensor sensing heights (p.727)” for details of the protective height. 5) The specifications of the sub-sensor for series connection are the same as for the light curtain, except for the current consumption. E EMITTER However, the sub-sensor is not equipped with an output. 6) Models which have an “ E EMITTER ” symbol in the model No. on the name plate are emitters, and those with a “ D RECEIVER ” symbol are receivers. Designation SF2C Current consumption (Note 5) Intermediate supporting bracket (Note) • MS-SF2B-2 M5 hexagonsocket-head bolt Purchase separately. ( ) Intermediate supporting bracket MS-SF2B-2 Light curtain SF2B Sensing surface BSF4-AH80 Test rod ø27 SF2B-TR27 Min. sensing object for regular checking (ø27 mm ø1.063 in), with hand protection type (min. sensing object ø27 mm ø1.063 in) Note: Depending on the product, the required set number will vary as follows. 1 set: SF2B-H□…Light curtain with 40 to 56 beam channels, SF2B-A□…Light curtain with 20 to 28 beam channels 2 sets: SF2B-H□…Light curtain with 64 to 80 beam channels, SF2B-A□…Light curtain with 32 to 40 beam channels 3 sets: SF2B-H□…Light curtain with 88 to 96 beam channels, SF2B-A□…Light curtain with 44 to 48 beam channels M5 hexagonsockethead bolt Purchase separately. ( ) Sensing surface Intermediate supporting bracket MS-SF2B-2 Light curtain Light Curtain Type 2 SF2B SERIES Ver.2 OPTIONS 616 FIBER SENSORS LASER SENSORS Exclusive control units Designation Appearance Connector connection type control unit Model No. Description Applicable cable SF2B-CB□ SFB-CCJ10□ SF-C11 PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Use 8-core cable with connector to connect to the light curtain. Compatible with up to control category 4 (control category 2 when used together with the SF2B series). AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS Slim type control unit Use a discrete wire cable to connect to the light curtain. Compatible with up to control category 4 (control category 2 when used together with the SF2B series). SF2B-CCB□ SFB-CC□ SF-C13 Note: Refer to the exclusive control units SF-C10 series pages for details. Front protection cover This protects the sensing surfaces of the light curtain from flying objects such as welding spatter, oil and water. The operating range reduces when the front protection cover is used. Material: Polycarbonate Sensing range Sensing range (Note) When using the SF2B-CB05-B When setting up the light curtains in the L-shape or U-shape, usually two or three sets of the light curtains are required. However, using the corner mirror to reflect the laser light allows only one set of the light curtains to be set up at the L-shape or U-shape. Only emitter 0.2 to 11.5 m 0.2 to 4.5 m installed 0.656 to 37.730 ft 0.656 to 14.764 ft Only receiver 0.2 to 11.5 m 0.2 to 4.5 m installed 0.656 to 37.730 ft 0.656 to 14.764 ft Both emitter and 0.2 to 10.0 m 0.2 to 4.0 m receiver installed 0.656 to 32.808 ft 0.656 to 13.123 ft Note: The “operating range” is the possible setting distance between the emitter and the receiver. Designation Applicable beam channels Front protection cover SIMPLE WIRE-SAVING UNITS Specifications • RF-SFBH-□ Item Type Model No. Corner mirror RF-SFBH-□ With one mirror: declined to 90 %, With two mirrors: declined to 80 % (When used in combination with the SF2B series) –10 to +55 °C +14 to +131 °F Ambient temperature (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F Sensing range Environmental resistance • FC-SF2BH-□ PARTICULAR USE SENSORS SENSOR OPTIONS Corner mirror Front protection cover INDUCTIVE PROXIMITY SENSORS Ambient humidity 30 to 85 % RH, Storage: 30 to 95 % RH 10 to 55 Hz frequency, Vibration resistance 0.75 mm 2.953 in amplitude in X, Y and Z directions for two hours each 300 m/s2 acceleration (30 G approx.) in X, Y Shock resistance and Z directions for three times each Enclosure: Aluminum, Mounting bracket: Stainless Steel, Material Mirror (rear surface mirror): Glass, Side cover: EPDM Intermediate supporting bracket: 1 set (RF-SFBH-40/48/56/64), Accessories 2 sets (RF-SFBH-72/80/88/96) Corner mirror RF-SFBH-□ Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Corner mirror Dimensions of effective reflective surface Hand Arm / Foot Model No. Model No. 8 4 FC-SF2BH-8 RF-SFBH-8 173 × 72 mm 6.811 × 2.835 in 12 6 FC-SF2BH-12 RF-SFBH-12 236 × 72 mm 9.291 × 2.835 in 16 8 FC-SF2BH-16 RF-SFBH-16 316 × 72 mm 12.441 × 2.835 in 20 10 FC-SF2BH-20 RF-SFBH-20 396 × 72 mm 15.591 × 2.835 in 24 12 FC-SF2BH-24 RF-SFBH-24 476 × 72 mm 18.740 × 2.835 in 28 14 FC-SF2BH-28 RF-SFBH-28 556 × 72 mm 21.890 × 2.835 in 32 16 FC-SF2BH-32 RF-SFBH-32 636 × 72 mm 25.039 × 2.835 in SF4B-C 36 18 FC-SF2BH-36 RF-SFBH-36 716 × 72 mm 28.190 × 2.835 in SF4C 40 20 FC-SF2BH-40 RF-SFBH-40 796 × 72 mm 31.339 × 2.835 in SF2C 48 24 FC-SF2BH-48 RF-SFBH-48 956 × 72 mm 37.638 × 2.835 in SF4B 56 28 FC-SF2BH-56 RF-SFBH-56 1,116 × 72 mm 43.937 × 2.835 in SF2B 64 32 FC-SF2BH-64 RF-SFBH-64 1,276 × 72 mm 50.236 × 2.835 in BSF4-AH80 72 36 FC-SF2BH-72 RF-SFBH-72 1,436 × 72 mm 56.535 × 2.835 in 80 40 FC-SF2BH-80 RF-SFBH-80 1,596 × 72 mm 62.835 × 2.835 in 88 44 FC-SF2BH-88 RF-SFBH-88 1,756 × 72 mm 69.134 × 2.835 in 96 48 FC-SF2BH-96 RF-SFBH-96 1,916 × 72 mm 75.433 × 2.835 in Note: The model Nos. given above denote a single unit, not a pair of units. 2 units are required for use in mounting to the emitter / receiver. Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights 617 FIBER SENSORS Light Curtain Type 2 SF2B SERIES Ver.2 OPTIONS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Designation Test rod ø47 Appearance Model No. Description SF2B-TR47 Min. sensing object for regular checking (ø47 mm ø1.850 in), with Arm / Foot protection type (min. sensing object ø47 mm ø1.850 in) AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS Specifications INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS Laser alignment tool SF-LAT-2B WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS • Supply voltage: 3 V • Battery: 1.5 V (AA size battery) × 2 pcs. (replaceable) • Battery lifetime: 30 hours approx. of continuous operation (Manganese battery, at +25 °C +77 °F ambient temperature) • Light source: Red semiconductor laser: class 2 (IEC / JIS / FDA) (Max. output: 1 mW, Peak emission wavelength: 650 nm 0.026 mil) • Ambient temperature: 0 to +40 °C +32 to +104 °F (No dew condensation) • Material: ABS (Enclosure) Aluminum (Mounting part:) • Weight: Net weight: 200 g approx. (including batteries) • Accessories AA size battery: 2 pcs. With the auxiliary output of the light curtain, the operation is easily observable from various directions. PLC Specifications HUMAN MACHINE INTERFACES • Supply voltage: 24 V DC ±15 % • Current consumption: 12 mA or less • Indicators: Orange LED (8 pcs. used) [Light up when external contact is ON] • Ambient temperature: –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed) • Material: POM (Enclosure) Polycarbonate (Cover) Cold rolled carbon steel (SPCC) (Bracket) • Cable: 0.3 mm2 2-core cabtyre cable, 3 m 9.843 ft long • Net weight: 70 g approx. (including bracket) ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS I/O circuit diagrams Color code (Brown) +V Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C Large display unit for light curtain + 24 V DC – ±15 % SF-IND-2 (Blue) –V *1 Users’ circuit Internal circuit *1 Non-voltage contact or NPN open-collector transistor or Color code (Brown) +V SF4C *1 SF2C + 24 V DC – ±15 % SF4B SF2B BSF4-AH80 • SF-LAT-2B Allows easy beam axis alignment using easy-to-see laser beam PRESSURE / FLOW SENSORS SENSOR OPTIONS Laser alignment tool (Blue) –V Internal circuit Users’ circuit *1 Non-voltage contact or PNP open-collector transistor or Large display unit for light curtain • SF-IND-2 Hexagon-sockethead bolt M5 (length 10 mm 0.394 in or more) (Purchase separately.) Attaches to top of light curtain. Tighten together the mounting bracket provided with the light curtain (MS-SF2B-1/4/5) and the mounting bracket of SF-IND-2. • Recommended safety relays Panasonic Corporation Model No.: SF series Note: Contact the manufacturers for details on the recommended products. Light Curtain Type 2 618 SF2B SERIES Ver.2 SPECIFICATIONS FIBER SENSORS LASER SENSORS Individual specifications SF2B-H□ PHOTOELECTRIC SENSORS Hand protection type Item Model No. Type Min. sensing object ø27 mm ø1.063 in type (20 mm 0.787 in beam pitch) NPN output SF2B-H8-N SF2B-H12-N SF2B-H16-N SF2B-H20-N SF2B-H24-N SF2B-H28-N MICRO PHOTOELECTRIC SENSORS PNP output SF2B-H8-P SF2B-H12-P SF2B-H16-P SF2B-H20-P SF2B-H24-P SF2B-H28-P 8 12 16 20 24 28 AREA SENSORS 392 mm 15.433 in 472 mm 18.583 in 552 mm 21.732 in Number of beam channels Beam pitch 20 mm 0.787 in Protective height 168 mm 6.614 in Current consumption PFHD 232 mm 9.134 in Emitter: 40 mA or less Receiver: 50 mA or less 312 mm 12.283 in Emitter: 40 mA or less Receiver: 60 mA or less NPN output 6.24 × 10–9 6.44 × 10–9 6.58 × 10–9 6.77 × 10–9 6.91 × 10–9 7.10 × 10–9 PNP output –9 –9 –9 –9 –9 –9 6.04 × 10 6.23 × 10 6.37 × 10 MTTFd 6.57 × 10 6.71 × 10 170 g approx. Model No. Type 280 g approx. 400 g approx. 510 g approx. 610 g approx. Min. sensing object ø27 mm ø1.063 in type (20 mm 0.787 in beam pitch) SF2B-H32-N SF2B-H36-N SF2B-H40-N SF2B-H48-N SF2B-H56-N SF2B-H64-N PNP output SF2B-H32-P SF2B-H36-P SF2B-H40-P SF2B-H48-P SF2B-H56-P SF2B-H64-P 32 36 40 48 56 64 Beam pitch 20 mm 0.787 in Protective height 632 mm 24.882 in PFHD 712 mm 28.031 in Emitter: 50 mA or less Receiver: 80 mA or less Current consumption 792 mm 31.181 in 952 mm 37.480 in Emitter: 60 mA or less Receiver: 90 mA or less 1,112 mm 43.779 in 1,272 mm 50.079 in Emitter: 65 mA or less Receiver: 110 mA or less NPN output 7.24 × 10–9 7.44 × 10–9 7.58 × 10–9 7.91 × 10–9 8.24 × 10–9 8.58 × 10–9 PNP output –9 –9 –9 –9 –9 8.37 × 10–9 7.04 × 10 7.23 × 10 7.37 × 10 MTTFd 7.71 × 10 8.04 × 10 100 years or more Net weight (total of emitter and receiver) 830 g approx. 930 g approx. 1,000 g approx. Model No. NPN output SF2B-H72-N SF2B-H80-N SF2B-H88-N SF2B-H96-N PNP output SF2B-H72-P SF2B-H80-P SF2B-H88-P SF2B-H96-P 72 80 88 96 Number of beam channels Beam pitch 1,500 g approx. 20 mm 0.787 in Protective height Current consumption 1,432 mm 56.378 in 1,592 mm 62.677 in 1,752 mm 68.976 in 1,912 mm 75.275 in Emitter: 70 mA or less Receiver: 130 mA or less Emitter: 80 mA or less Receiver: 150 mA or less NPN output 8.91 × 10–9 9.24 × 10–9 9.58 × 10–9 9.91 × 10–9 PNP output 8.71 × 10–9 9.04 × 10–9 9.37 × 10–9 9.71 × 10–9 1,900 g approx. 2,100 g approx. MTTFd Net weight (total of emitter and receiver) PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC 1,300 g approx. Type Min. sensing object ø27 mm ø1.063 in type (20 mm 0.787 in beam pitch) PFHD 720 g approx. NPN output Number of beam channels Item 6.90 × 10 100 years or more Net weight (total of emitter and receiver) Item Emitter: 50 mA or less Receiver: 70 mA or less LIGHT CURTAINS / SAFETY COMPONENTS 1,700 g approx. HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 100 years or more 2,300 g approx. 2,500 g approx. Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C SF4C SF2C SF4B SF2B BSF4-AH80 619 SF2B-A□ PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Type Item WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS SF2B-A4-N SF2B-A6-N SF2B-A8-N SF2B-A10-N SF2B-A12-N SF2B-A14-N PNP output SF2B-A4-P SF2B-A6-P SF2B-A8-P SF2B-A10-P SF2B-A12-P SF2B-A14-P 4 6 8 10 12 14 392 mm 15.433 in 472 mm 18.583 in 552 mm 21.732 in Beam pitch 40 mm 1.575 in Protective height 168 mm 6.614 in PFHD 232 mm 9.134 in Emitter: 35 mA or less Receiver: 45 mA or less Current consumption 312 mm 12.283 in Emitter: 35 mA or less Receiver: 50 mA or less 6.11 × 10–9 6.23 × 10–9 6.30 × 10–9 6.42 × 10–9 6.49 × 10–9 6.62 × 10–9 PNP output –9 –9 –9 –9 –9 6.41 × 10–9 5.90 × 10 6.03 × 10 6.10 × 10 6.22 × 10 6.29 × 10 100 years or more Net weight (total of emitter and receiver) 170 g approx. Type Item Emitter: 40 mA or less Receiver: 55 mA or less NPN output MTTFd 280 g approx. 400 g approx. 510 g approx. 610 g approx. Min. sensing object ø47 mm ø1.850 in type (40 mm 1.575 in beam pitch) SF2B-A16-N SF2B-A18-N SF2B-A20-N SF2B-A24-N SF2B-A28-N SF2B-A32-N PNP output SF2B-A16-P SF2B-A18-P SF2B-A20-P SF2B-A24-P SF2B-A28-P SF2B-A32-P 16 18 20 24 28 32 Beam pitch 40 mm 1.575 in Protective height 632 mm 24.882 in PFHD 712 mm 28.031 in Emitter: 40 mA or less Receiver: 60 mA or less Current consumption 792 mm 31.181 in 952 mm 37.480 in Emitter: 45 mA or less Receiver: 65 mA or less 1,112 mm 43.779 in 1,272 mm 50.079 in Emitter: 50 mA or less Receiver: 75 mA or less NPN output 6.69 × 10–9 6.81 × 10–9 6.88 × 10–9 7.08 × 10–9 7.27 × 10–9 7.46 × 10–9 PNP output –9 –9 –9 –9 –9 7.26 × 10–9 6.48 × 10 6.61 × 10 6.68 × 10 MTTFd 6.87 × 10 7.07 × 10 100 years or more Net weight (total of emitter and receiver) 830 g approx. 930 g approx. 1,000 g approx. 1,300 g approx. 1,500 g approx. Type Min. sensing object ø47 mm ø1.850 in type (40 mm 1.575 in beam pitch) Item NPN output SF2B-A36-N SF2B-A40-N SF2B-A44-N SF2B-A48-N PNP output SF2B-A36-P SF2B-A40-P SF2B-A44-P SF2B-A48-P 36 40 44 48 Number of beam channels Beam pitch 40 mm 1.575 in Protective height Current consumption PFHD 1,432 mm 56.378 in 1,592 mm 62.677 in 1,752 mm 68.976 in 1,912 mm 75.275 in Emitter: 55 mA or less Receiver: 85 mA or less Emitter: 60 mA or less Receiver: 95 mA or less NPN output 7.66 × 10–9 7.85 × 10–9 8.05 × 10–9 8.24 × 10–9 PNP output 7.46 × 10–9 7.65 × 10–9 7.84 × 10–9 8.04 × 10–9 MTTFd Net weight (total of emitter and receiver) 100 years or more 1,900 g approx. 2,100 g approx. 2,300 g approx. 2,500 g approx. Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C SF4C SF2C SF4B SF2B BSF4-AH80 720 g approx. NPN output Number of beam channels HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Min. sensing object ø47 mm ø1.850 in type (40 mm 1.575 in beam pitch) NPN output Number of beam channels SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Model No. MICRO PHOTOELECTRIC SENSORS Arm / Foot protection type Model No. LASER SENSORS SF2B SERIES Ver.2 SPECIFICATIONS Model No. FIBER SENSORS Light Curtain Type 2 1,700 g approx. Light Curtain Type 2 SF2B SERIES Ver.2 620 SPECIFICATIONS FIBER SENSORS LASER SENSORS Common specifications Type Applicable standards (Note 2) Item Model No. International standard Japan Europe (EU) North America Operating range Min. sensing object Effective aperture angle Supply voltage Control outputs (OSSD 1, OSSD 2) Operation mode Protection circuit Response time Auxiliary output (Aux) (Note 4) Operation mode Protection circuit Synchronization method Interference prevention function Environmental resistance Emission halt function External device monitoring function Degree of protection Ambient temperature / Ambient humidity Ambient illuminance Dielectric strength voltage / Insulation resistance Vibration resistance / Shock resistance Emitting element Cable extension Connecting method Material Accessories Min. sensing object ø27 mm ø1.063 in type (20 mm 0.787 in beam pitch) Min. sensing object ø47 mm ø1.850 in type (40 mm 1.575 in beam pitch) NPN output PNP output NPN output PNP output SF2B-H□-N SF2B-H□-P SF2B-A□-N SF2B-A□-P IEC 61496-1/2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL1) JIS B 9704-1/2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 EN 61496-1 (Type 2), EN 55011 UL 61496-1/2 (Type 2), UL 508, UL 1998 (Class 1), CSA C22.2 No.14, CSA C22.2 No.0.8, OSHA 1910.212 (Note 3), OSHA 1910.217 (C) (Note 3), ANSI B11.1 to B11.19, ANSI/RIA 15.06 0.2 to 13 m 0.656 to 42.651 ft (0.2 to 5 m 0.656 to 16.404 ft when using the SF2B-CB05-B adapter cable) ø27 mm ø1.063 in opaque object ø47 mm ø1.850 in opaque object ±5° or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)] 24 V DC ±15 %   Ripple P-P 10 % or less PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS NPN open-collector transistor PNP open-collector transistor • Max. sink current: 200 mA • Max. source current: 200 mA • Applied voltage: same as supply voltage • Applied voltage: same as supply voltage [between the control outputs (OSSD 1, OSSD 2) and 0 V] [between the control outputs (OSSD 1, OSSD 2) and +V] • Residual voltage: 2.0 V or less (sink current 200 mA) • Residual voltage: 2.5 V or less (sink current 200 mA) (when using 30.5 m 100.066 ft length cable) (when using 30.5 m 100.066 ft length cable) PARTICULAR USE SENSORS ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the light curtain or the synchronization signal) Incorporated OFF response: 15 ms or less, ON response: 40 to 60 ms WIRE-SAVING SYSTEMS NPN open-collector transistor • Max. sink current: 60 mA • Applied voltage: same as supply voltage [between the auxiliary output and 0 V] • Residual voltage: 2.0 V or less (sink current 60 mA) (when using 30.5 m 100.066 ft length cable) PNP open-collector transistor • Max. source current: 60 mA • Applied voltage: same as supply voltage [between the auxiliary output and +V] • Residual voltage: 2.5 V or less (sink current 60 mA) (when using 30.5 m 100.066 ft length cable) When using SF2B-CCB□ or SF2B-CB□: OFF when OSSD ON, ON when OSSD OFF When using SF2B-CB05-A: ON during normal operation, OFF when there is a problem with emitter operation or emission is halted Incorporated Cable synchronization (optical synchronization when using SF2B-CB05-B) Incorporated • Series connection: 3 sets max. (Total 128 beam channels). (However, SF2B-A□ allows up to a total of 96 beam channels when two sets are connected, and up to 64 beam channels when three sets are connected). (Note 5) SF2B-H□ and SF2B-A□ can be used together. (Note 6) When using SF2B-CB05-B (optical synchronization): • Series connection: 3 sets max. (Total 128 beam channels). (However, SF2B-A□ allows up to a total of 96 beam channels when two sets are connected, and up to 64 beam channels when three sets are connected). (Note 5) • Parallel connection: 2 sets max. • Series and parallel mixed connection: Series connection of 3 sets max. and parallel connection of 2 sets max. are simultaneously possible. SF2B-H□ and SF2B-A□ can be used together. (Note 6) Incorporated Incorporated IP65 (IEC) (*IP67 is later than Ver.2) –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F/ 30 to 85 % RH, Storage: 30 to 95 % RH Incandescent light: 3,500 ℓx or less at the light-receiving face 1,000 V AC for one min. between all supply terminals connected together and enclosure / 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure 10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each / 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) Extension up to total 30.5 m 100.066 ft is possible for both emitter and receiver, with optional mating cables. Connector Enclosure: Aluminum, Upper and lower edges : Die-cast zinc alloy, Inner case: Polycarbonate · Polyester resin, Cap: PBT MS-SF2B-2 (Intermediate supporting bracket): (Note 7) MS-SF2B-2 (Intermediate supporting bracket): (Note 7) SF2B-TR27 (Test rod): 1 No. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) The SF2B series manufactured from October 2009 applies PLd and SIL2, which are based on IEC 61496-1: 2006(Safety of machinery - Electro-sensitive protective equipment - Part 1). Due to the revision of international standard IEC 61496-1: 2012, the usage of Type 2 safety light curtain is limited to PLc and SIL1 after May 10th, 2015. 3) Not compatible when using the bottom cap cable SF2B-CB05-A. 4) When using auxiliary output (AUX), the compatible cable SF2B-CB05-B (sold separately) cannot be used. 5) SF2B-H8-□ and SF2B-A4-□ cannot be connected in series. For more information, refer to ‘‘PRECAUTIONS FOR PROPER USE (p.626~)’’. 6) When making series connection mixing SF2B-H□ and SF2B-A□, calculate by doubling the number of optical axes only for SF2B-A□, and make the total number of optical axes fall below 128 axes. (e.g.) When making series connection with SF2B-H36 and SF2B-A44, the total number of optical axes will be 124 axes. The number of optical axes for SF2B-H36 + (number of optical axes for SF2B-A44 × 2) = total number of optical axes. 36 optical axes + (44 optical axes × 2) = 124 optical axes. 7) Intermediate supporting bracket MS-SF2B-2 is included with the following products. The number included varies as follows depending on the product. 1 set: SF2B-H□…Light curtain with 40 to 56 beam channels, SF2B-A□…Light curtain with 20 to 28 beam channels 2 sets: SF2B-H□…Light curtain with 64 to 80 beam channels, SF2B-A□…Light curtain with 32 to 40 beam channels 3 sets: SF2B-H□…Light curtain with 88 to 96 beam channels, SF2B-A□…Light curtain with 44 to 48 beam channels SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C SF4C SF2C SF4B SF2B BSF4-AH80 621 Light Curtain Type 2 I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS NPN output type Connector pin No. Color code of mating cable Emitter 3 (Blue) 0 V 7 Receiver LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Internal circuit (Shield) (Black) OSSD 1 3 (White) OSSD 2 1 7 Internal circuit BSF4-AH80 2 K1: External device Users’ circuit (Force-guided relay or magnet contactor) – 24 V DC ±15 % 7 5 6 Cable color: Gray with black line (Orange / Black) (Orange) (Brown) 4 (Brown) +V (Shield) (Yellow-green / Black) Auxiliary output (Pink) Test input 3 (Blue) 0 V * S1 Note: Unused wires must be insulated to ensure that they do not come into contact with wires already in use. Emitter + – 24 V DC ±15% 7 2 6 Internal circuit 5 8 3 1 Color code of mating cable 8 4 7 5 6 Cable color: Gray (Orange) Synchronization + (Orange / Black) Synchronization – Users’ circuit (Orange / Black) Synchronization – (Orange) Synchronization + (Brown) +V (Shield) K1 Load (Black) OSSD 1 200 mA max. (White) OSSD 2 (Yellow-green) External device monitoring input 200 mA max. 4 (Blue) 0 V 7 1 3 1 (Pale purple) Not connected 5 K1: External device Users’ circuit (Force-guided relay or magnet contactor) Note: Unused wires must be insulated to ensure that they do not come into contact with wires already in use. CAUTION Construct the interlock (reset input) circuit separately. * S1 Switch S1 • Test input Open: Emission halt 0 to +1.5 V (source current 5 mA or less): Emission K1 K1: External device (Force-guided relay or magnet contactor) Connector pin No. Color code of mating cable Emitter Sensor circuit + 8 4 (Black) K1 (White) Load (Yellow-green) (Blue) • In order to disable the external device monitoring function, connect the auxiliary output and external device monitoring input. At such times, do not connect a load to the auxiliary output. Sensor circuit * S1 (Shield) Switch S1 • Test input Open: Emission halt 0 to +1.5 V (source current 5 mA or less): Emission Internal circuit Load 1 3 * S1 SF2C (Shield) 200 mA max. Construct the interlock (reset input) circuit separately. 2 SF2B Receiver Load CAUTION Receiver (Brown) (Blue) (Pale purple) (Orange) (Orange / Black) Note: Unused wires must be insulated to ensure that they do not come into contact with wires already in use. 6 SF4B Cable color: Gray (Pink) (Yellow-green) External device monitoring input 200 mA max. 4 K1 (Blue) 0 V Definition of Sensing Heights SF4C 7 6 (Yellow-green / Black) K1 8 Control Units SF4B-C Color code of mating cable 8 5 2 Light Curtains Optical Touch Switch 1 4 (Orange / Black) Synchronization – (Orange) Synchronization + 5 (Brown) +V 8 Safety Components 2 3 * S1 (Orange) Synchronization + 6 (Orange / Black) Synchronization – Users’ circuit 2 Selection Guide 24 V DC ±15 % 6 MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES – 5 Sensor circuit WIRE-SAVING SYSTEMS + 1 (Pale purple) Not connected SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Emitter (Brown) +V 2 (Shield) 8 Load (Yellow-green / Black) Auxiliary output 4 60 mA max. (Pink) Test input INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Wiring diagram Sensor circuit PRESSURE / FLOW SENSORS When using a SF2B-CCB□ or SF2B-CB□ bottom cap cable I/O circuit diagram AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS SF2B SERIES Ver.2 (Yellow-green / Black) + (Pink) * S1 – 24 V DC ±15 % (Blue) (Pale purple) (Orange) (Orange / Black) Receiver 2 (Brown) (Shield) 1 3 8 4 7 5 6 Cable color: Gray with black line (Orange / Black) (Orange) (Brown) (Shield) (Black) K1 (White) (Yellow-green) Load (Blue) K1: External device (Force-guided relay or magnet contactor) Note: Unused wires must be insulated to ensure that they do not come into contact with wires already in use. Light Curtain Type 2 SF2B SERIES Ver.2 I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS PNP output type When using a SF2B-CCB□ or SF2B-CB□ bottom cap cable I/O circuit diagram Wiring diagram Connector pin No. Color code of mating cable Emitter Sensor circuit (Brown) +V 2 (Pink) Test input 3 (Yellow-green / Black) Auxiliary output 4 (Shield) 8 (Blue) 0 V – 24 V DC ±15 % 1 (Pale purple) Not connected 6 Internal circuit 2 3 8 7 5 6 Color code of mating cable Cable color: Gray Load – 24 V DC ±15 % (Blue) (Pale purple) (Orange) (Orange / Black) Receiver K1 (Yellow-green) External device monitoring input (Black) OSSD 1 200 mA max. 3 (White) OSSD 2 200 mA max. + Users’ circuit 2 K1 K1: External device (Force-guided relay or magnet contactor) WIRE-SAVING SYSTEMS 8 4 7 5 6 Cable color: Gray with black line CAUTION Construct the interlock (reset input) circuit separately. (Black) (White) (Shield) (Blue) Switch S1 • Test input Open: Emission halt Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note 2) Sensor circuit 4 (Brown) +V (Pink) Test input (Yellow-green / Black) Auxiliary output * S1 + – (Shield) 8 (Blue) 0 V 24 V DC ±15 % Internal circuit FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 2 1 3 Color code of mating cable 8 7 5 6 Cable color: Gray (Orange) Synchronization + (Orange / Black) Synchronization – Users’ circuit (Orange / Black) Synchronization – 6 (Orange) Synchronization + 5 (Brown) +V (Brown) Selection Guide (Pink) * S1 (Yellow-green / Black) + (Shield) – 24 V DC ±15 % (Blue) (Pale purple) (Orange) (Orange / Black) Receiver Sensor circuit 2 (Yellow-green) External device monitoring input 4 (Black) OSSD 1 200 mA max. 3 (White) OSSD 2 200 mA max. 1 (Shield) 8 (Blue) 0 V 7 Internal circuit Users’ circuit Load K1 K1: External device (Force-guided relay or magnet contactor) CAUTION Construct the interlock (reset input) circuit separately. * S1 Switch S1 • Test input Open: Emission halt Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note 2) Notes: 1) Unused wires must be insulated to ensure that they do not come into contact with wires already in use. 2) Vs is the applying supply voltage. HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS 1 (Pale purple) Not connected 6 PLC Note: Unused wires must be insulated to ensure that they do not come into contact with wires already in use. 4 7 5 Load Emitter Connector pin No. Color code of mating cable 3 LASER MARKERS K1 K1: External device (Force-guided relay or magnet contactor) • In order to disable the external device monitoring function, connect the auxiliary output and external device monitoring input. At such times, do not connect a load to the auxiliary output. 2 STATIC ELECTRICITY PREVENTION DEVICES (Orange) (Yellow-green) K1 * S1 Emitter MEASUREMENT SENSORS (Orange / Black) (Brown) Notes: 1) Unused wires must be insulated to ensure that they do not come into contact with wires already in use. 2) Vs is the applying supply voltage. PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS 1 3 INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS 4 Internal circuit Receiver (Pink) * S1 (Shield) Load MICRO PHOTOELECTRIC SENSORS PRESSURE / FLOW SENSORS (Brown) (Yellow-green / Black) 2 1 (Shield) 8 (Blue) 0 V 7 PHOTOELECTRIC SENSORS LIGHT CURTAINS / SAFETY COMPONENTS 1 4 (Orange) Synchronization + (Orange / Black) Synchronization – Users’ circuit (Orange / Black) Synchronization – 6 (Orange) Synchronization + 5 (Brown) +V Sensor circuit Receiver Load LASER SENSORS AREA SENSORS 7 5 Emitter * S1 60 mA max. + 622 2 1 3 7 5 6 Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C 8 4 Light Curtains SF4C Cable color: Gray with black line (Orange / Black) SF2C (Orange) SF4B (Brown) SF2B (Yellow-green) (Black) (White) (Shield) (Blue) K1 Load K1: External device (Force-guided relay or magnet contactor) Note: Unused wires must be insulated to ensure that they do not come into contact with wires already in use. BSF4-AH80 623 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Light Curtain Type 2 I/O CIRCUIT AND WIRING DIAGRAMS SF-C11 SF2B series wiring diagram (Control category 2) • Set the light curtain input polarity selection switch to the NPN side and ground the + side. Light curtain input polarity selection switch STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS A1 F.G. Receiver side connector UV CURING SYSTEMS Emitter side connector Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C SF4C SF2C SF4B SF2B BSF4-AH80 NPN SF-C11 control circuit PNP Ui OUT A2 AUX T2 0 V TEST (Note 3) FUSE1 13 23 FUSE2 Terminal arrangement diagram 33 41 Terminal K1 A1 A2 INTER_LOCK 13 FAULT T1 14 24 34 42 KA, KB: Force-guided relay or KB magnet contactor KA N L1 L2 L3 14 KB KA 23 X1 X2 X3 A B T1 T2 AUX 24 33 34 41 M 3 42 Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) Emission halt occurs when the test (TEST) button is open, and emission occurs when the test (TEST) button is short-circuited. If not using the test (TEST) button, short-circuit T1 and T2. However, use a test rod or similar to interrupt the light in order to carry out self-diagnosis separately. • Set the light curtain input polarity selection switch to the PNP side and ground the 0 V line. Light curtain input polarity selection switch +24 V DC A1 Receiver side connector RESET (Note 1) (Note 1, 2) X1 X2 X3 A B F Ui NPN SF-C11 control circuit PNP 13 23 2 OUT AUX T2 0 V TEST (Note 3) INTER_LOCK 1 14 24 34 42 T1 KA, KB: Force-guided relay or KB magnet contactor KA N 41-42 Auxiliary output (NC contact × 1) X1 Reset output terminal X2 Reset input terminal (Manual) X3 Reset input terminal (Automatic) Not used T1 Test output terminal T2 Test input terminal AUX Semiconductor auxiliary output Emitter side connector Receiver side connector Not used OSSD2 2 +24 V DC +24 V DC 3 Emission halt OSSD1 4 Auxiliary output EDM (External relay monitor) KB 5 Synchronization wire + Synchronization wire + KA 6 Synchronization wire – Synchronization wire – 7 0V 0V 8 Shield wire Shield wire 5 L1 L2 L3 Safety output (NO contact × 3) 1 7 6 4 K1 FAULT 13-14, 23-24, 33-34 Connector pin No. 8 33 41 K2 Emitter side connector A2 0V Pin layout for light curtain connectors 3 FUSE2 +24 V DC A2 B L1 FUSE1 Function A1 A PNP output type F.G. Selection Guide F L1 K2 FA COMPONENTS MACHINE VISION SYSTEMS RESET (Note 1) (Note 1, 2) X1 X2 X3 A B +24 V DC SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS Be sure to use the following mating cables when connecting SF-C11 to SF2B series. SF2B-CB05 (cable length: 0.5 m 1.640 ft) SF2B-CB5 (cable length: 5 m 16.404 ft) SF2B-CB10 (cable length: 10 m 32.808 ft) SFB-CCJ10E (for emitter, cable length: 10 m 32.808 ft) SFB-CCJ10D (for receiver, cable length: 10 m 32.808 ft) NPN output type SENSOR OPTIONS WIRE-SAVING SYSTEMS SF2B SERIES Ver.2 M 3 Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) Emission halt occurs when the test (TEST) button is open, and emission occurs when the test (TEST) button is short-circuited. If not using the test (TEST) button, short-circuit T1 and T2. However, use a test rod or similar to interrupt the light in order to carry out self-diagnosis separately. Light Curtain Type 2 SF2B SERIES Ver.2 I/O CIRCUIT AND WIRING DIAGRAMS 624 FIBER SENSORS LASER SENSORS SF-C13 PHOTOELECTRIC SENSORS SF2B series wiring diagram (Control category 2) Terminal arrangement diagram NPN output type • Connect the light curtain control outputs OSSD 1 and OSSD 2 to S4 and S2 respectively and ground the + side. Emitter Receiver Cable color: Gray with black line Cable color: Gray (Orange) Synchronization + +V (Brown) +24 V DC (Orange / Black) Synchronization – Shield Test input Auxiliary output (Pink) (Yellow-green / Black) 0V Load (Blue) Shield +V (Brown) 0 V (Blue) External device monitoring input (Yellow-green) OSSD 2 (White) A1 A2 S1 S2 S3 S4 AUX X1 X2 X3 13 14 23 24 33 34 41 42 Terminal Function A1 +24 V DC A2 0V S1 to S4 Light curtain control output (OSSD) input terminal AUX Semiconductor auxiliary output X1 Reset output terminal X2 Reset input terminal (Manual) X3 Reset input terminal (Automatic) 13-14, 23-24, 33-34 Safety output (NO contact × 3) 41-42 Auxiliary output (NC contact × 1) L1 (Note 1) FUSE1 F.G. S1 S2 S3 S4 X1 X2 X3 13 23 F Ui Use a separate terminal block to carry out wiring for light curtains that cannot be connected to the SF-C13. FUSE2 33 41 RESET (Note 1, 2) K1 K2 A2 AUX 0V INTER_LOCK 14 24 34 42 KA, KB: Force-guided relay or KB magnet contactor KA N L1 L2 L3 KB KA M 3 Notes: 1) The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. Auxiliary output (Yellow-green / Black) +V (Brown) Load SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS UV CURING SYSTEMS Selection Guide (Orange / Black) Synchronization – 0V (Blue) SENSOR OPTIONS Receiver Cable color: Gray with black line Cable color: Gray Test input (Pink) PARTICULAR USE SENSORS MACHINE VISION SYSTEMS (Orange) Synchronization + Shield INDUCTIVE PROXIMITY SENSORS FA COMPONENTS • Connect the light curtain control outputs OSSD 1 and OSSD 2 to S1 and S2 respectively. +V (Brown) +24 V DC PRESSURE / FLOW SENSORS PLC FAULT PNP output type Emitter LIGHT CURTAINS / SAFETY COMPONENTS LASER MARKERS SF-C13 control circuit OUT AREA SENSORS WIRE-SAVING SYSTEMS OSSD 1 (Black) A1 MICRO PHOTOELECTRIC SENSORS Light Curtains Safety Components Shield Optical Touch Switch Control Units 0 V (Blue) External device monitoring input (Yellow-green) Definition of Sensing Heights OSSD 2 (White) OSSD 1 (Black) SF4B-C L1 RESET (Note 1, 2) A1 S1 S2 S3 (Note 1) FUSE1 S4 X1 X2 F X3 13 23 SF4C FUSE2 SF2C 33 41 SF4B K1 Ui SF2B SF-C13 control circuit BSF4-AH80 K2 OUT A2 0V AUX F.G. INTER_LOCK FAULT 14 24 KA, KB: Force-guided relay or magnet contactor KA N 34 42 L1 L2 L3 KB KB KA M 3 Notes: 1) The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. • This light curtain is a Type 2 electro-sensitive protective equipment. It is specified that this light curtain be utilized only within systems implementing control categories 2, 1 and B (safety-related categories for control systems), as determined by European Standard EN 954-1. This light curtain must never be utilized in any system that requires the usage of category 4 equipment, such as press machines; nor for systems requiring category 3 equipment. • To use this product in the U.S.A., refer to OSHA 1910. 212 and OSHA 1910. 217 for installation, and in Europe, refer to EN 999 as well. Observe your national and local requirements before installing this product. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS • Make sure to carry out the test run before regular operation. • This safety system is for use only on machinery in which the dangerous parts can be stopped immediately, either by an emergency stop unit or by disconnecting the power supply. Do not use this system with machinery which cannot be stopped at any point in its operation cycle. Self-diagnosis function • This light curtain incorporates the self-diagnosis function. In case an abnormality is detected during self-diagnosis, the light curtain is put in the lockout state at that instant, and the control output (OSSD 1, OSSD 2) is fixed at the OFF state. Refer to “Troubleshooting” and the instruction manual and remove the cause of the abnormality. • In order to maintain safe condition of light curtain, inspect the beam interrupted status of the device once a day or more. Failure to do so could delay the detection of unexpected abnormality and increase the degree of hazard, which may cause the malfunction of light curtain, resulting in serious body injury or death. • In order to check all abnormalities in the OSSD 1, OSSD 2 and auxiliary output, the beam interrupted status of device must be checked. Perform either of two below to inspect the device under beam interrupted status. • Emission halt by test input (Emission halt function) • Beam interrupting by test rod (Excluding the cable SF2B-CB05-A) Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units SF4B-C SF4C SF2C SF4B SF2B BSF4-AH80 Open 20 ms or less 20 ms or less 20 ms or less Short-circuited Test input Open When using the SF2B-CB05-B Short-circuited Emission status 20 ms or less Emission Emission halt 40 to 60 ms 15 ms or less Control outputs ON (OSSD 1, OSSD 2) OFF Do not use the emission halt function (test input) for the purpose of stopping the device. Failure to do so could result in serious injury or death. Auxiliary output • This catalog is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use. • Both emitter and receiver are combined adjusted on factory setting, please apply both emitter and receiver with the same serial No. The serial No. is indicated on the plates of both emitter and receiver. (Indicated under the model No.) UV CURING SYSTEMS Definition of Sensing Heights Test input Emission halt function (Test input) • This function stops the emission process of the emitter. You can select whether emission is on or halted by means of the connection status for the test input (pink). Test input Open Connected to 0 V or +V Emission status • Auxiliary output is incorporated into the emitter and its operation varies depending on the type of bottom cap cable (optional) to be used. Normal mode Bottom cap cable Control outputs Emission (OSSD 1, OSSD 2) status halt Lockout Beam received Beam interrupted When using the SF2B-CCB□ / SF2B-CB□ ON OFF ON ON When using the SF2B-CB05-A OFF ON ON OFF SF2B-CB05-B Cannot be used. When bottom cap cable SF2B-CCB□ or SF2B-CB□ (optional) is used • The auxiliary output is incorporated in the emitter. It is OFF when the control outputs (OSSD 1,OSSD 2) are ON and vice versa. • The auxiliary output can be used as an operation monitor of the device. • When the external device monitor function is not used, connect the external device monitor input line to the auxiliary output line to disable the function. In this case, do not connect the load to the auxiliary output. For details, refer to “External device monitoring function (p.626)” and “ I/O CIRCUIT AND WIRING DIAGRAMS (p.621~)”. • When the external device monitoring function is used to disable, do not directly use the auxiliary output as the operation monitor of this light curtain. When the external device monitor is used to disable and the auxiliary output is used to monitor the operation of light curtain, connect the auxiliary output and the external device monitoring input to the external relay (purchase separately) to use the external relay contacting point as an operation monitor of this light curtain. Receiver MEASUREMENT SENSORS When using the SF2B-CB05-B Emission halt Emission Emission Emission halt • During emission halt, the control outputs (OSSD 1, OSSD 2) become OFF status. • By using this function, malfunction due to extraneous noise or abnormality in the control outputs (OSSD 1, OSSD 2) and the auxiliary output can be determined even from the machinery side. External device monitoring input (Yellow-green) WIRE-SAVING SYSTEMS Refer to p.1458~ for general precautions. The instruction manual can be downloaded from our website. PRECAUTIONS FOR PROPER USE LASER SENSORS SIMPLE WIRE-SAVING UNITS SF2B SERIES Ver.2 Emitter FIBER SENSORS Light Curtain Type 2 Auxiliary output (Yellow-green / Black) 625 Use as operation monitoring External relay (Purchase separately.) Connect NPN output type to +V and connect PNP output type to 0 V Connect NPN output type to 0 V and connect PNP output type to +V Light Curtain Type 2 PRECAUTIONS FOR PROPER USE Beam received Beam received condition Beam interrupted Control outputs (OSSD 1, OSSD 2) 40 to 60 ms OFF 20 ms or less 20 ms or less OFF When bottom cap cable SF2B-CB05-A (optional) is used Make sure to use the auxiliary output when using the bottom cap cable SF2B-CB05-A (optional). Set the device so the control machine can be stopped when either the control output (OSSD 1) or auxiliary output turns to OFF. If the auxiliary output is should not be used, the device cannot stop operation when an unexpected error occurs during control output (OSSD 1) failure, which may result in serious injury or death. • The auxiliary output is incorporated in the emitter. It outputs ON at the normal operation of device. It outputs OFF in the following cases: • When an abnormality which needs emission halt status occurs [for example, the control output (OSSD 1) shortcircuit and an error occurs.] • While test input has been input • The error cannot be transmitted to the control machine. The alarm signal is output from the auxiliary output. Control output (OSSD1) Auxiliary output Control output (OSSD1) short-circuited ON OFF Beam received Beam received condition Beam interrupted Control outputs (OSSD 1, OSSD 2) ON ON Auxiliary output 15 ms or less 300 ms or less 300 ms or less ON External device monitoring input OFF • The time set for external device monitoring is 300 ms or less. Exceeding 300 ms turns the light curtain into lockout condition. Beam received Beam received condition Beam interrupted Control outputs ON (OSSD 1, OSSD 2) OFF ON External device monitoring input When bottom cap cable SF2B-CB05-B (optional) is used • The auxiliary output cannot be utilized by using the bottom cap cable SF2B-CB05-B (optional). External device monitoring function • This function is available when the bottom cap cable SF2B-CCB□ or SF2B-CB□ (optional) is used. This is the function for checking whether the external safety relay connected to the control outputs (OSSD 1, OSSD 2) performs normally in accordance with the control outputs (OSSD 1, OSSD 2) or not. Monitor the b contact of the external safety relay, and if any abnormality such as deposit of the contacting point, etc. is detected, change the status of the light curtain into lockout one, and turn OFF the control outputs (OSSD 1, OSSD 2). In case of setting the external device monitoring function to enabled • Connect the external device monitoring input (yellow-green) to the b contact of the external safety relay that is connected to the control outputs (OSSD 1, OSSD 2). Lockout condition LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS 40 to 60 ms Beam received Beam received condition Beam interrupted MEASUREMENT SENSORS ON Control outputs (OSSD 1, OSSD 2) OFF STATIC ELECTRICITY PREVENTION DEVICES 300 ms ON OFF Lockout condition LASER MARKERS PLC • This is the configuration for connecting multiple sets of emitters and receivers facing each other in series. It is used when the dangerous part can be entered from two or more directions. The control outputs (OSSD 1, OSSD 2) turns OFF if any of the light curtain is interrupted. For details, refer to the instruction manual. Notes 1): Series connection connectors cannot be used with the SF2B-H8-□ and SF2B-A4-□, and so series connection is not possible. The SF2B-H8SL and SF2B-A4SL are not equipped with series connection connectors, so when connecting three sets in series, they cannot be used in the middle position. 2): The total number of beam axes for the SF2B-A□ is a maximum of 96 when two sets are connected, and 64 when three sets are connected. When SF2B-H□ and SF2B-A□ are combined in series connection, double the number of the beam channels of SF2B-A□ to calculate the total number of beam channels, which should be 128 or less. Example: The total no. of beam channels for SF2B-H36 and SF2B-A44 is 124. The no. of beam channels of SF2B-H36 + (the No. of beam channels of SF2B-A44 × 2) = Total no. of beam channels 36 beam channels + (44 beam channels × 2) = 124 beam channels For serial connections, connect the emitter and receiver of the light curtain to the emitter and receiver respectively of the sub-sensors for series connection using the SF2B-CSL□ special series connection cables. Wrong connection could generate the nonsensing area, resulting in serious injury or death. HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C Emitter 3 Receiver 3 Emitter 2 Receiver 2 Sub-sensor for series connection only SF2B-□SL (Optional) SF2B-H8SL and SF2B-A4SL cannot be used. Receiver 1 Cable for series connection SF2B-CSL□ (Optional) Sub-sensor for series connection only SF2B-□SL (Optional) SF2B-H8SL and SF2B-A4SL can be used. Emitter 1 • Connect the external device monitoring input (yellowgreen) to the auxiliary output (yellow-green / black). Receiver AREA SENSORS SENSOR OPTIONS 300 ms In case of not using the external device monitoring function External device monitoring input (Yellow-green) MICRO PHOTOELECTRIC SENSORS PARTICULAR USE SENSORS OFF External device monitoring input PHOTOELECTRIC SENSORS INDUCTIVE PROXIMITY SENSORS 15 ms or less Connectable up to 3 sets of light curtains (however, 128 beam channels max.) (Note 1, 2) OFF Emitter 40 to 60 ms ON OFF FIBER SENSORS LASER SENSORS 15 ms or less Series connection Beam interrupted ON Auxiliary output (Yellow-green / Black) 626 Refer to p.1458~ for general precautions. The instruction manual can be downloaded from our website. SF2B SERIES Ver.2 Synchronization + (Orange) Synchronization – (Orange / Black) Light curtain SF2B-H8-□ and SF2B-A4-□ cannot be used. * When using the SF2B-CB05-B, set the frequency selection switches (for both emitter and receiver) to “1”. SF4C SF2B SF2C SF4B BSF4-AH80 Series and parallel mixed connection • Up to a maximum of two sets can be connected in parallel only when using the SF2B-CB05-B adapter cable (optional). For details, refer to the instruction manual. INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Interference prevention Light curtain SF2B-H8-□ and SF2B-A4-□ cannot be used * Set the frequency selection switches (for both emitter and receiver) to “1” at the master units, and set them to “2” at the slave units. SENSOR OPTIONS Interference prevention * Set the frequency selection switches (for both emitter and receiver) to “1” at the master units, and set them to “2” at the slave units. SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Part description and function Receiver A HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS A B Beam-axis alignment indicator [RECEPTION] Beam-axis alignment indicator [RECEPTION] C D PLC Top end Emitter STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS Receiver 3 PRESSURE / FLOW SENSORS Cable for series connection SF2B-CSL□ (Optional) Receiver 3 Sub-sensor for serial connection only SF2B-□SL (Optional) Receiver 2 Emitter 1 LIGHT CURTAINS / SAFETY COMPONENTS Receiver 1 AREA SENSORS • Up to a maximum of three sets can be connected in a mixture of series and parallel (for a total maximum number of 128 beam channels. However, the total number of beam channels for the SF2B-A□ is a maximum of 96 when two sets are connected, and 64 when three sets are connected.) only when using the SF2B-CB05-B adapter cable (optional). For details, refer to the instruction manual. Emitter 2 MICRO PHOTOELECTRIC SENSORS Parallel connection Receiver 2 PHOTOELECTRIC SENSORS Refer to p.1458~ for general precautions. The instruction manual can be downloaded from our website. PRECAUTIONS FOR PROPER USE Emitter 2 LASER SENSORS SF2B SERIES Ver.2 Receiver 1 FIBER SENSORS Light Curtain Type 2 Emitter 1 627 Operation indicator [OPERATION] Emission halt indicator [HALT] Beam-axis alignment indicator [RECEPTION] Fault indicator [FAULT] A B C D B OSSD indicator [OSSD] C Incident light intensity indicator [STB] D Fault indicator [FAULT] Digital error indicator Setting indicator [SETTING] FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Light Curtains Safety Components Frequency selection switch Description Beam-axis alignment indicator (Red / Green) [RECEPTION] Definition of Sensing Heights SF4B-C SF4C Function A B When all beam channels of light curtain upper middle are receiving light: lights up in red When control outputs (OSSD 1, OSSD 2) are ON: lights up in green (always off when using the SF2B-CB05-B) C When all beam channels of light curtain lower middle are receiving light: lights up in red When control outputs (OSSD 1, OSSD 2) are ON: lights up in green (always off when using the SF2B-CB05-B) D When all beam channels of light curtain bottom are receiving light: lights up in red When sensor bottom end receives light: blinks in red When control outputs (OSSD 1, OSSD 2) are ON: lights up in green (always off when using the SF2B-CB05-B) Operation indicator (Red / Green) [OPERATION] When control outputs (OSSD 1, OSSD 2) are OFF: lights up in red When control outputs (OSSD 1, OSSD 2) are ON: lights up in green When using the SF2B-CB05-B When fault occurs in the emitter: light up in red When emitter is normal: light up in green Emission halt indicator (Orange) [HALT] When light emission is halt: lights up When light is emitted: lights off SF2C SF4B SF2B BSF4-AH80 1 When all beam channels of light curtain top are receiving light: lights up in red When light curtain top end receives light: blinks in red When control outputs (OSSD 1, OSSD 2) are ON: lights up in green (always off when using the SF2B-CB05-B) Optical Touch Switch Control Units 2 Fault indicator (Yellow) [FAULT] When fault occurs in the sensor: lights up or blinks Setting indicator (Red) [SETTING] Always off When using the SF2B-CB05-B One lights up when set to Frequency 1 Two light up when set to Frequency 2 Frequency selection switch Used for switching between master and slave when using the SF2B-CB05-B. Set to “1” for master and “2” for slave. Bottom end Description Function A Beam-axis alignment indicator (Red / Green) [RECEPTION] B C D When all beam channels of light curtain top are receiving light: lights up in red When sensor top end receives light: blinks in red When control outputs (OSSD 1, OSSD 2) are ON: lights up in green When all beam channels of light curtain upper middle are receiving light: lights up in red When control outputs (OSSD 1, OSSD 2) are ON: lights up in green When all beam channels of light curtain lower middle are receiving light: lights up in red When control outputs (OSSD 1, OSSD 2) are ON: lights up in green When all beam channels of light curtain bottom are receiving light: lights up in red When sensor bottom end receives light: blinks in red When control outputs (OSSD 1, OSSD 2) are ON: lights up in green OSSD indicator (Red / Green) [OSSD] When control outputs (OSSD 1, OSSD 2) are OFF: lights up in red When control outputs (OSSD 1, OSSD 2) are ON: lights up in green Incident light intensity indicator (Orange / Green) [STB] When sufficient light is received (incident light intensity: 130 % or more) (Note 1): lights up in green When stable light is received (incident light intensity: 115 to 130 %) (Note 1): OFF When unstable light is received (incident light intensity: 100 to 115 %) (Note 1): lights up in orange When light is interrupted: OFF (Note 2) Fault indicator (Yellow) [FAULT] When fault occurs in the sensor: lights up or blinks Digital error indicator (Red)(Note 3) When device is lockout: lights up for malfunction content When using the SF2B-CB05-B Display shows fault contents during lockout. Center lights up when set to Frequency 1 Center and bottom lights up when set to Frequency 2 Frequency selection switch Used for switching between master and slave when using the SF2B-CB05-B. Set to “1” for master and “2” for slave. Notes: 1) The threshold value where the control output changes from OFF to ON is applied as “100 % incident light intensity”. 2) The status “when light is interrupted” refers to the status that the some obstacle is existed in the sensing area. 3) For details, refer to “Troubleshooting (p.629)” and the SF2B instruction manual. 4) The description given in [ ] is marked on the light curtain. Light Curtain Type 2 PRECAUTIONS FOR PROPER USE SF2B SERIES Ver.2 Refer to p.1458~ for general precautions. The instruction manual can be downloaded from our website. Wiring FIBER SENSORS LASER SENSORS Refer to the applicable regulations for the region where this light curtain is to be used when setting up the light curtain. In addition, make sure that all necessary measures are taken to prevent possible dangerous operating errors resulting from earth faults. • Make sure to carry out the wiring in the power supply off condition. • Verify that the supply voltage variation is within the rating. • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground. • Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Sensing area • Make sure to install this product such that any part of the human body must pass through its sensing area in order to reach the dangerous parts of the machinery. If the human body is not detected, there is a danger of serious injury or death. • Do not use any reflective type or retroreflective type arrangement. • Emitter and receiver that face each other should be from the same model No. (with same beam axis pitch and number of beam channels) and aligned in the vertical direction. If units from different sets are connected together, it may cause blind spots in the sensing area, and death or serious injury may result. • Furthermore, facing several receivers towards one emitter, or vice versa, could produce a non-sensing area or cause mutual interference, which may result in serious injury or death. Correct mounting method Dangerous part 628 Sensing area Protective structure Dangerous part Sensing area Wrong mounting method Sensing area Dangerous part Dangerous part Sensing area Safety distance • Calculate the safety distance correctly, and always maintain a distance which is equal to or greater than the safety distance, between the sensing area of this light curtain and the dangerous parts of the machinery. (Please check the latest standards for the equation.) If the safety distance is miscalculated or if sufficient distance is not maintained, there is a danger of serious injury or death. • Before designing the system, refer to the relevant standards of the region where this device is to be used and then install this device. Dangerous part of machine Emitter S Beam axis Receiver S: Safety distance • Safety distance is calculated based on the following equation when a person moves perpendicular (normal intrusion) to the sensing area of the light curtain. In case the intrusion direction is not perpendicular to the sensing area, be sure to refer to the relevant standard (regional standard, specification of the machine, etc.) for details of the calculation. (Please check the latest standards for the equation.) For use in Europe (EU) (as EN 999)(Also applicable to ISO 13855) For intrusion direction perpendicular to the sensing area • Equation 1 S=K×T+C S: Safety distance (mm) Minimum required distance between the sensing area surface and the dangerous parts of the machine K: Intrusion speed of operator’s body or objects (mm/sec.) Normally, taken as SF2B-H□ 2,000 (mm/sec.), SF2B-A□ 1,600 (mm/sec.) for calculation. T: Response time of total equipment (sec.) T = Tm + TSF2B Tm: Maximum halting time of machinery (sec.) TSF2B: Response time of the SF2B series 0.015 (sec.) C: Additional distance calculated from the size of the minimum sensing object of the light curtain (mm) However, the value of “C” cannot be 0 or less. C = 8 × (d – 14) d: Minimum sensing object diameter SF2B-H□: d= 27 (mm) 1.063 (in), C = 104 (mm) 4.094 (in) For SF2B-A□, C = 850 (mm) 33.465 (in) (constant) • For calculating the safety distance “S”, there are the following five cases. First calculate by substituting the value K = 2,000 (mm/sec.) in the equation above. Then, classify the obtained value of “S” into three cases, 1) S < 100, 2) 100 ≤ S ≤ 500, and 3) S > 500. For Case 3) S > 500, recalculate by substituting the value K = 1,600 (mm/sec.). After that, classify the calculation result into two cases, 4) S ≤ 500 and 5) S > 500. For details, refer to the instruction manual enclosed with this product. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS For use in the United States of America (as per ANSI B11.19) • Equation 2 S = K × (Ts + Tc + TSF2B + Tbm) + Dpf S: Safety distance (mm) Minimum required distance between the sensing area surface and the dangerous parts of the machine K: Intrusion velocity {Recommended value in OSHA is 63 (inch/sec.) ≈ 1,600 (mm/sec.)} ANSI B11.19 does not define the intrusion velocity “K”. When determining K, consider possible factors including physical ability of operators. Ts: Halting time calculated from the operation time of the control element (air valve, etc.) (sec.) Tc: Maximum response time of the control circuit required for functioning the brake (sec.) TSF2B: Response time of light curtain 0.015 (sec.) Tbm: Additional halting time tolerance for the brake monitor (sec.) Tbm = Ta – (Ts + Tc) Ta: Setting time of brake monitor (sec.) When the machine is not equipped with a brake monitor, it is recommended that 20 % or more of (Ts + Tc) is taken as additional halting time. Dpf: Additional distance calculated from the size of the minimum sensing object of the light curtain SF2B-H□ Dpf = 2.676 (inch) ≈ 68 (mm) SF2B-A□ Dpf = 5.355 (inch) ≈ 136 (mm) Dpf = 3.4 × (d – 0.276) (inch) Dpf ≈ 3.4 × (d – 7) (mm) d: Minimum sensing object diameter 1.063 (inch) ≈ 27 (mm) SF2B-H□ Minimum sensing object diameter 1.851 (inch) ≈ 47 (mm) SF2B-A□ Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C SF4C SF2C SF4B SF2B BSF4-AH80 629 Influence of reflective surfaces PHOTOELECTRIC SENSORS Install the light curtain by considering the effect of nearby reflective surfaces, and take countermeasures such as painting, masking, or changing the material of the reflective surface, etc. Failure to do so may cause the light curtain not to detect, resulting in serious body injury or death. MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS • Keep the minimum distance given below, between the light curtain and a reflective surface. Side view Emitter Sensing area L SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Reflective floor Distance between emitter and receiver (Setting distance L) Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C SF4C SF2C SF4B SF2B BSF4-AH80 A 6° 6° (Note 2) Receiver L 1.5 4.921 A Allowable installation distance A 0.2 to 3 m 0.32 m 1.050 ft 0.656 to 9.843 ft L / 2 × tan2θ 3 to 13 m 9.843 to 42.651 ft = L × 0.106 (m) 0.348 (ft) (Note 1) (θ = 6°) 1.2 3.937 Install in this area Symptoms All indicators are off. 0.6 1.969 Do not install in this area 3 6 9 12 13 9.843 19.685 29.528 39.370 42.651 Distance between emitter and receiver (m ft) Troubleshooting Emitter side Symptoms Cause Power is not being supplied. Supply voltage is out of the specified range. Connector is not connected securely. Operation indicator The beam channels remains lit up in red the emitter and (beam is not received). of [OPERATION] the receiver are not correctly aligned. Emission is in halt condition. The synchronization wire error The receiver does not work. Emission halt The interference indicator (orange) prevention wire error lights up. When using the [HALT] SF2B-CB05-B: When set to slave Master / slave setting error When using the SF2B-CB05-B: When set to master The master sensor does not work. [Blinks once] Fault indicator Total light curtains (yellow) lights up or No. / total beam channel No. error blinks. [FAULT] [Blinks twice] Auxiliary output error or [Other than the above] Effect from noise / power supply or failure of internal circuit Remedy Check that the power supply capacity is sufficient. Connect the power supply correctly. Provide the supply voltage within the specified range. Connect the connector securely. Align the beam channels. Connect the test input (emission halt input) wire correctly. The logic varies depending on the cable to be used. Connect the synchronization wire correctly. Check the operation of the receiver side. Connect the interference prevention wire correctly. Set the master / slave setting to “master”. Check the master side light curtain. Connect the end cap properly. Connect the cable for series connection correctly. Check the model (emitter / receiver) of sub-sensor for series connection. Set the No. of the light curtains in series connection, and a total No. of beam channels within the specification. Connect the auxiliary output cable correctly. Check the noise status around this light curtains. Check the wiring, supplied voltage and power supply capacity. Even if the error is not eliminated, contact our office. Fault indicator (yellow) lights up or blinks. [FAULT] or Remedy Power is not being supplied. Check that the power supply capacity is sufficient. Connect the power supply correctly. Supply voltage is output of the specified range. Set the supply voltage correctly. Connector is not connected securely. The beam channels of the emitter and the receiver are not correctly aligned. Total unit No. / total beam channel No. error Connect the connector securely. Stable indicator The beam channels lights up (Orange) of the emitter and the [STB] receiver are not correctly aligned. 0.3 0.984 0 Cause OSSD indicator remains lit up in red (beam is not received). The master / slave setting is different. [OSSD] When using with the SF2B-CB05-B 0.9 2.953 Notes: 1) If using the SF2B-CB05-B, the operating range is 0.3 to 5 m 0.984 to 16.404 ft. 2) The effective aperture angle for this device is ±5° or less (when L > 3 m 9.843 ft) as required by IEC 61496-2 / UL 61496-2. However, install this device away from reflective surfaces considering an effective aperture angle of ±6° to take care of beam misalignment, etc. during installation. All indicators are off. Selection Guide Reflective surface A Emitter SENSOR OPTIONS Receiver side Top view Reflective ceiling INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Refer to p.1458~ for general precautions. The instruction manual can be downloaded from our website. PRECAUTIONS FOR PROPER USE Allowable installation distance A (m ft) LASER SENSORS SF2B SERIES Ver.2 Receiver FIBER SENSORS Light Curtain Type 2 Align the beam channels. Set the same value to the Nos. of emitter and receiver. Set the setting identically. Align the beam channels. [Digital error indicator ] Total light curtain No. / total beam channel No. error Connect the end cap properly. Connect the cable for series connection correctly. Check the model (emitter / receiver) of sub sensor for series connection. Check that the number of light curtains / number of beam axes is within the specification value. [Digital error indicator ] Control outputs (OSSD 1, OSSD 2) error Connect the control outputs (OSSD1, OSSD2) correctly. [Digital error indicator ] Extraneous light error Prevent any extraneous light from entering the receiver. [Digital error indicator ] External device monitoring error Connect the external device monitor input wire correctly. Replace the replay unit. Replace the relay unit having appropriate response time. [Digital error indicator ] Bottom connector error Check the type of the bottom connector. Cable of the emitter: Grey (with black stripe) [Other than the above] Effect from noise / power supply or failure of internal circuit Check the noise status around this light curtain. Check the wiring, supplied voltage and power supply capacity. Even if the error is not eliminated, contact our office. Corner mirror • Be sure to carry out maintenance while referring to the instruction manual for the SF4B / SF2B series of light curtains. • Do not use if dirt, water, or oil, etc. is attached to the reflective surface of this product. Appropriate sensing range may not be maintained due to diffusion or refraction. • Make sure that you have read the instruction manual for the corner mirror thoroughly before setting up the corner mirrors and light curtains, and follow the instructions given. If the equipment is not set up correctly as stipulated in the instruction manual, incident light errors may result in unexpected situations which may result in serious injury or death. • Please download the instruction manuals from our website. • Light curtain SF4B / SF2B series cannot be used as a retroreflective type. Avoid installing the light curtain as a retroreflective type when this product is applied. • The mirror part of this product is made of glass. Note that if it is broken, the glass shards may fly apart. Light Curtain Type 2 DIMENSIONS (Unit: mm in) 630 SF2B SERIES Ver.2 The CAD data in the dimensions can be downloaded from our website. SF2B-□  SF2B-□SL LASER SENSORS Light curtain, Sub-sensor for series connection only PHOTOELECTRIC SENSORS Assembly dimensions Mounting drawing for the light curtains using the standard mounting brackets MS-SF2B-1 (optional) and the intermediate supporting brackets MS-SF2B-2 (accessory for light curtain). 53 2.087 Standard mounting bracket MS-SF2B-1 (Optional) 28 1.102 18 0.709 5.5 0.217 2.5 0.098 5 0.197 End cap J 28 1.102 (Note 2) 26 1.024 26 1.024 24 0.945 28 1.102 18 0.709 5.5 0.217 2.5 0.098 24 0.945 41 1.614 5 0.197 20 0.787 28 1.102 24 0.945 ABC CBA 20 0.787 F 20 0.787 5.5 0.217 E Beam pitch 5 0.197 D 30.5 1.201 AREA SENSORS 41 1.614 5 0.197 J 28 1.102 24 0.945 INDUCTIVE PROXIMITY SENSORS 20 0.787 20 0.787 G G H H Emitter Bottom cap cable 20 0.787 20 0.787 F 20 0.787 5.5 0.217 E D Beam pitch 5 0.197 G 32.5 1.280 Receiver 20 0.787 5.5 0.217 E H 5 0.197 G 32.5 1.280 H Bottom cap cable Emitter D Receiver Notes: 1) The MS-SF2B-2 intermediate supporting bracket is provided as an accessory with this product. The number of accessories provided varies depending on the product. 2) An end cap (connector for series connection) is not provided for the SF2B-H8(SL)(-□) and SF2B-A4(SL)(-□). A B C D E F Model No. G H J (Note) SF2B-A4(SL)(-□) 168 6.614 207 8.150 223 8.780 – – – SF2B-H□ 20 0.787 6 0.236 6 0.236 SF2B-H12(SL)(-□) SF2B-A6(SL)(-□) 232 9.134 270 10.630 286 11.260 – – – SF2B-A□ 40 1.575 26 1.024 6 0.236 SF2B-H16(SL)(-□) SF2B-A8(SL)(-□) 312 12.283 350 13.780 366 14.409 – – – SF2B-H20(SL)(-□) SF2B-A10(SL)(-□) 392 15.433 430 16.929 446 17.559 – – – SF2B-H24(SL)(-□) SF2B-A12(SL)(-□) 472 18.583 510 20.079 526 20.709 – – – SF2B-H28(SL)(-□) SF2B-A14(SL)(-□) 552 21.732 590 23.228 606 23.858 – – – SF2B-H32(SL)(-□) SF2B-A16(SL)(-□) 632 24.882 670 26.378 686 27.008 – – – SF2B-H36(SL)(-□) SF2B-A18(SL)(-□) 712 28.031 750 29.528 766 30.157 – – – SF2B-H40(SL)(-□) SF2B-A20(SL)(-□) 792 31.181 830 32.677 846 33.307 390 15.354 – – SF2B-H48(SL)(-□) SF2B-A24(SL)(-□) 952 37.480 990 38.976 1,006 39.606 470 18.504 – – SF2B-H56(SL)(-□) SF2B-A28(SL)(-□) 1,112 43.779 1,150 45.276 1,166 45.905 550 21.654 – – SF2B-H64(SL)(-□) SF2B-A32(SL)(-□) 1,272 50.079 1,310 51.575 1,326 52.205 418 16.457 842 33.150 – SF2B-H72(SL)(-□) SF2B-A36(SL)(-□) 1,432 56.378 1,470 57.874 1,486 58.504 472 18.583 948 37.323 – SF2B-H80(SL)(-□) SF2B-A40(SL)(-□) 1,592 62.677 1,630 64.173 1,646 64.803 525 20.669 1,055 41.535 – SF2B-H88(SL)(-□) SF2B-A44(SL)(-□) 1,752 68.976 1,790 70.472 1,806 71.102 433 17.047 870 34.252 1,308 51.496 SF2B-H96(SL)(-□) SF2B-A48(SL)(-□) 1,912 75.275 1,950 76.772 1,966 77.401 473 18.622 950 37.402 1,428 56.220 Model No. SF2B-H8(SL)(-□) SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS F 5 0.197 D 30.5 1.201 PARTICULAR USE SENSORS SENSOR OPTIONS A CB BC A LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS Protective height F E 10.5 0.413 18 0.709 5.5 14 0.217 0.551 22.5 0.886 22.5 0.886 28 1.102 28 1.102 Protective height 20 0.787 20 0.787 5.5 0.217 5 0.197 10.5 0.413 18 0.709 5.5 14 0.217 0.551 J J 28 1.102 20 0.787 Intermediate supporting bracket MS-SF2B-2 (Note 1)(Accessory) MICRO PHOTOELECTRIC SENSORS 53 2.087 FIBER SENSORS Note: The distance between the tip of the light curtain and the last beam axis of the  SF2B-H8(SL)(-□) and SF2B-A4(SL)(-□) is 22 mm 0.866 in. MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Light Curtains Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C SF4C SF2C SF4B SF2B BSF4-AH80 631 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Light Curtain Type 2 DIMENSIONS (Unit: mm in) SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Light curtain, Sub-sensor for series connection only Assembly dimensions Mounting drawing for the light curtains using the dead zoneless mounting brackets MS-SF2B-3 (optional) and the intermediate supporting brackets MS-SF2B-2 (accessory for light curtain). End cap (Note 2) 53 2.087 50 1.969 Dead zoneless mounting bracket MS-SF2B-3 (Optional) 1.7 0.067 Intermediate supporting bracket MS-SF2B-2 Dead zoneless mounting bracket (Note 1) (Accessory) MS-SF2B-3 Spacer for intermediate supporting bracket (Optional) (Accessory for MS-SF2B-3) 50 1.7 0.067 1.969 End cap 41 1.614 (Note 2) 53 2.087 50 1.969 1.7 0.067 J 54 2.126 J 24 0.945 41 1.614 28 1.102 28 1.102 A K 20 0.787 24 0.945 1.3 0.051 3 54 0.118 2.126 G G 6.5 0.256 5.5 0.217 Bottom 30.5 cap cable 1.201 (Optional) Beam H pitch 19 0.748 24 26 0.945 1.024 3 0.118 54 2.126 5.5 0.217 H 19 0.748 30.5 1.201 26 24 1.024 0.945 Emitter 54 2.126 6.5 0.256 5.5 0.217 6.5 0.256 3 0.118 26 1.024 Q P 5.5 0.217 3 0.118 1.3 0.051 P 27.1 1.067 1.1 0.043 31.3 1.232 Bottom cap cable (Optional) 2 (0.079 ) 2 (0.079 ) 1.1 H 0.043 31.3 1.232 1.1 (0.043 ) Receiver Emitter 3 0.118 G G Beam pitch H 16.5 0.650 24 0.945 5.5 0.217 41 1.614 Q 3 0.118 K 5 R 0.197 41 1.614 5.5 0.217 L L 5 0.197 R 5.5 0.217 M 5 0.197 28 1.102 41 A A 41 1.614 1.614 20 0.787 N 5.5 0.217 5 0.197 41 1.614 Protective height K KA 20 0.787 20 0.787 5.5 0.217 27.1 1.067 54 2.126 J 20 0.787 Protective 28 height 1.102 M J 24 0.945 20 0.787 N 54 2.126 54 2.126 50 1.969 1.7 0.067 41 1.614 4 4 (0.157 ) (0.157 ) Intermediate supporting bracket MS-SF2B-2 (Note 1)(Accessory) LASER MARKERS PLC The CAD data in the dimensions can be downloaded from our website. SF2B-□  SF2B-□SL PARTICULAR USE SENSORS SENSOR OPTIONS SF2B SERIES Ver.2 54 2.126 5.5 0.217 16.5 0.650 6.5 0.256 26 1.024 1.1 (0.043 ) 27.1 1.067 27.1 1.067 Receiver Notes: 1) The MS-SF2B-2 intermediate supporting bracket is provided as an accessory with this product. The number of accessories provided varies depending on the product. 2) An end cap (connector for series connection) is not provided for the SF2B-H8(SL)(-□) and SF2B-A4(SL)(-□). Selection Guide Model No. L M N P Q R SF2B-A4(SL)(-□) 168 6.614 155 6.102 – – – – – – SF2B-H12(SL)(-□) SF2B-A6(SL)(-□) 232 9.134 219 8.622 – – – – – – SF2B-H16(SL)(-□) SF2B-A8(SL)(-□) 312 12.283 299 11.772 – – – – – – SF2B-H20(SL)(-□) SF2B-A10(SL)(-□) 392 15.433 379 14.921 – – – – – – SF2B-H24(SL)(-□) SF2B-A12(SL)(-□) 472 18.583 459 18.071 – – – – – – SF2B-H28(SL)(-□) SF2B-A14(SL)(-□) 552 21.732 539 21.221 – – – – – – SF2B-H32(SL)(-□) SF2B-A16(SL)(-□) 632 24.882 619 24.370 – – – – – – SF2B-H36(SL)(-□) SF2B-A18(SL)(-□) 712 28.031 699 27.520 – – – – – – SF2B-H40(SL)(-□) SF2B-A20(SL)(-□) 792 31.181 779 30.669 390 15.354 – – 379.5 14.941 – – SF2B-H48(SL)(-□) SF2B-A24(SL)(-□) 952 37.480 939 36.969 470 18.504 – – 459.5 18.091 – – SF2B-H56(SL)(-□) SF2B-A28(SL)(-□) 1,112 43.779 1,099 43.268 550 21.654 – – Light Curtains SF2B-H8(SL)(-□) Safety Components Optical Touch Switch Control Units Definition of Sensing Heights SF4B-C SF4C SF2C SF4B SF2B BSF4-AH80 A K – 539.5 21.240 SF2B-H64(SL)(-□) SF2B-A32(SL)(-□) 1,272 50.079 1,259 49.567 418 16.457 842 33.150 – 407.5 16.043 831.5 32.736 – – SF2B-H72(SL)(-□) SF2B-A36(SL)(-□) 1,432 56.378 1,419 55.866 472 18.583 948 37.323 – 461.5 18.169 937.5 36.909 – SF2B-H80(SL)(-□) SF2B-A40(SL)(-□) 1,592 62.677 1,579 62.165 525 20.669 1,055 41.535 – 514.5 20.256 1,044.5 41.122 – SF2B-H88(SL)(-□) SF2B-A44(SL)(-□) 1,752 68.976 1,739 68.465 433 17.047 870 34.252 1,308 51.496 422.5 16.634 859.5 33.839 1,297.5 51.083 SF2B-H96(SL)(-□) SF2B-A48(SL)(-□) 1,912 75.275 1,899 74.764 473 18.622 950 37.402 1,428 56.220 462.5 18.209 939.5 33.839 1,417.5 55.807 Model No. G H J (Note) SF2B-H□ 20 0.787 6 0.236 6 0.236 SF2B-A□ 40 1.575 26 1.024 6 0.236 Note: T  he distance between the tip of the light curtain and the last beam axis of the SF2B-H8(SL)(-□) and SF2B-A4(SL)(-□) is 22 mm 0.866 in. Light Curtain Type 2 DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. RF-SFBH-□ Corner mirror (Optional) 6 17.5 0.236 0.689 18 0.709 6 0.236 t3 t 0.118 26 13 1.024 0.512 t3 t 0.118 Model No. A B C RF-SFBH-8 173 6.811 236 9.291 316 12.441 396 15.591 476 18.740 556 21.890 636 25.039 716 28.189 796 31.339 956 37.638 1,116 43.937 1,276 50.236 1,436 56.353 1,596 62.835 1,756 69.134 1,916 75.433 183 7.205 246 9.685 326 12.835 406 15.984 486 19.134 566 22.283 646 25.433 726 28.583 806 31.732 966 38.031 1,126 44.331 1,286 50.630 1,446 56.929 1,606 63.228 1,766 69.527 1,926 75.827 235 9.252 298 11.732 378 14.882 458 18.031 538 21.181 618 24.331 698 27.480 778 30.630 858 33.779 1,018 40.079 1,178 46.378 1,338 52.677 1,498 58.976 1,658 65.275 1,818 71.575 1,978 77.874 29 1.142 RF-SFBH-12 29 1.142 RF-SFBH-16 RF-SFBH-20 80 3.150 RF-SFBH-24 ø8.5 ø0.335 A B C 18 0.709 6 0.236 6 17.5 0.689 0.236 RF-SFBH-28 F RF-SFBH-32 E 26 13 1.024 0.512 RF-SFBH-36 D RF-SFBH-40 ø8.5 ø0.335 RF-SFBH-48 72 2.835 106 4.173 45° 109 ( 4.219 ) 64 2.520 28 1.102 632 SF2B SERIES Ver.2 46 1.811 < When mounting at an angle of 45° > 104 ( 4.094 ) 46 (1.811 ) RF-SFBH-56 RF-SFBH-64 RF-SFBH-72 RF-SFBH-80 RF-SFBH-88 RF-SFBH-96 MS-SF2B-1 D E – – – – – – – – – – – – – – – – 458 ± 50 18.031 ± 1.969 538 ± 50 21.181 ± 1.969 618 ± 50 24.331 ± 1.969 698 ± 50 27.480 ± 1.969 538 ± 50 21.181 ± 1.969 591 ± 50 23.268 ± 1.969 645 ± 50 25.394 ± 1.969 698 ± 50 27.480 ± 1.969 – – – – 1,018 ± 50 40.079 ± 1.969 1,125 ± 50 44.291 ± 1.969 1,231 ± 50 48.464 ± 1.969 1,338 ± 50 52.677 ± 1.969 F Net weight 209 8.228 272 10.709 352 13.858 432 17.008 512 20.157 592 23.307 672 26.457 752 29.606 832 32.756 992 39.055 1,152 45.354 1,312 51.653 1,472 57.953 1,632 64.252 1,792 70.551 1,952 76.850 810 g approx. 970 g approx. 1,170 g approx. 1,370 g approx. 1,570 g approx. 1,770 g approx. 1,970 g approx. 2,170 g approx. 2,660 g approx. 3,060 g approx. 3,460 g approx. 3,890 g approx. 4,550 g approx. 4,950 g approx. 5,350 g approx. 5,750 g approx. Standard mounting bracket (Optional) Rear mounting 6 0.236 22.5 0.886 16.5 0.650 3.5 9.5 0.138 0.374 30° 16.5 0.650 22.5 0.88616.5 9.5 0.650 0.374 6 0.236 9.5 30° 0.374 5.3 0.209 4 0.157 8.2 0.323 5.5 0.217 13.5 0.531 18 0.709 28 12 1.102 0.472 9.5 0.374 30° 13.5 16.5 0.531 0.650 3.5 0.138 5.5 0.217 28 1.102 8.2 0.323 5.5 0.217 18 0.709 5.5 0.217 20.5 0.807 28 1.102 t2 t 0.079 16.5 0.650 22.5 0.886 9.5 16.5 0.650 0.374 30° 6 0.236 5.3 0.209 4 3.5 13.5 0.531 0.157 0.138 18 3.5 0.709 8.2 0.323 0.138 5.5 0.217 5.5 0.217 9.5 0.374 5 0.197 8.8 0.346 16.5 13.5 0.650 0.531 5.3 0.209 19.3 0.760 10.5 0.413 28 1.102 22.5 0.886 16.5 0.650 t2 t 0.079 30° 20.5 0.807 SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES Selection Guide Light Curtains Optical Touch Switch SF4B-C 9.5 0.374 SF4C SF2C 9.5 0.374 12 28 30° 0.472 1.102 4 0.157 Four brackets (R type × 2 and L type × 2) per set. M3 (length 5 mm 0.197 in) hexagonsocket-head bolts (eight bolts for light curtain mounting, eight bolts for beam axis alignment) are attached. SENSOR OPTIONS Definition of Sensing Heights 5.5 0.217 18 0.709 8.2 0.323 SF4B 5.5 0.217 3.5 0.138 5 0.197 8.8 0.346 Material: Stainless steel (SUS304) 8 0.315 PARTICULAR USE SENSORS Control Units 6 0.236 3.5 0.138 INDUCTIVE PROXIMITY SENSORS Safety Components Side mounting 28 1.102 12 0.472 30° PRESSURE / FLOW SENSORS 19.3 0.760 Rear mounting LIGHT CURTAINS / SAFETY COMPONENTS 3.5 0.138 8 0.315 20.5 0.807 t2 t 0.079 AREA SENSORS UV CURING SYSTEMS 5 0.197 8.8 0.346 10.5 0.413 MICRO PHOTOELECTRIC SENSORS MACHINE VISION SYSTEMS 5.3 0.209 4 0.157 3.5 0.138 8 0.315 PHOTOELECTRIC SENSORS FA COMPONENTS 19.3 5 0.197 0.760 8.8 0.346 10.5 0.413 LASER SENSORS ENERGY CONSUMPTION VISUALIZATION COMPONENTS Side mounting 28 1.102 12 0.472 30° FIBER SENSORS 19.3 0.760 8 0.315 28 1.102 10.5 0.413 20.5 0.807 t2 t 0.079 SF2B BSF4-AH80 633 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS Light Curtain Type 2 SF2B SERIES Ver.2 DIMENSIONS (Unit: mm in) MS-SF2B-3 Dead zoneless mounting bracket (optional) Main body Spacer for intermediate supporting bracket (Accessory) 14 0.551 12 0.472 LIGHT CURTAINS / SAFETY COMPONENTS 14 0.551 PRESSURE / FLOW SENSORS 2-M5 5.5 0.217 17 0.669 23 0.906 R32.5 R27.3 25.4° 10° 10° 9.5 0.374 3 0.118 60 2.362 31.5 1.240 14 20 0.551 0.787 1.7 0.067 1.7 0.067 PLC 33 1.299 Mounting adjustment range 10° 10° 6.5 0.256 5.5 0.217 22 0.866 50 1.969 MS-SF2B-2 Intermediate supporting bracket (Accessory for light curtain) 5.5 0.217 30 20 1.181 0.787 6 0.236 6 0.236 8 0.315 18 0.709 18 0.709 8 0.315 8 0.315 6 6 0.236 0.236 17 18 0.669 0.709 10 0.394 18 0.709 6 0.236 4 0.157 10 0.394 t1 t 0.039 5.5 0.217 4 0.157 18 0.709 5.5 0.217 8.2 0.323 15 0.591 13.8 8 0.315 0.543 t2 t 0.079 30.8 34.8 1.213 1.370 Material: Stainless steel (SUS304) 27 17 1.063 0.669 15 0.591 Material: Stainless steel (SUS304) SF4B 7.7 0.303 SF2B BSF4-AH80 21 0.827 28 1.102 28 1.102 5.5 0.217 5 0.197 SF2C 26 9.5 0.374 16.5 0.650 1.024 20 30 0.787 1.181 15 0.591 t1 t 0.039 12 0.472 5.5 0.217 8 0.315 5.5 0.217 5 0.197 MS-SF2B-4 Adapter mounting bracket for SF1-N / NA40 (Optional) SF4B-C SF4C 11.5 Material: Stainless steel (SUS304) 0.453 Six brackets set Twelve M5 (length 8 mm 0.315 in) hexagon-socket-head bolts are attached. The adjustment range of the light curtain angle is up to ±10 degrees. 67 2.638 3 0.118 FA COMPONENTS Definition of Sensing Heights t2 t 0.079 50 1.969 22 0.866 54 2.126 ENERGY CONSUMPTION VISUALIZATION COMPONENTS 3 0.118 33 1.299 HUMAN MACHINE INTERFACES Control Units 16 0.630 54 2.126 14 0.551 40 31.5 20 1.575 1.240 0.787 LASER MARKERS Optical Touch Switch 54 2.126 5.5 0.217 14 0.551 3 0.118 Four bracket set STATIC ELECTRICITY PREVENTION DEVICES Safety Components 15 0.591 L-shaped mounting MEASUREMENT SENSORS Light Curtains t2 t 0.079 Material: Stainless steel (SUS304) • Die-cast zinc alloy SIMPLE WIRE-SAVING UNITS Selection Guide 5.5 0.217 20 31 41 56 0.787 1.220 1.614 2.205 9 0.118 M5 hexagonsocket-head bolts 26 27.1 1.024 1.067 15 0.591 30 1.181 36 1.417 51.7 2.035 SENSOR OPTIONS UV CURING SYSTEMS 3 0.118 Center of rotation Angle of movable ranges PARTICULAR USE SENSORS MACHINE VISION SYSTEMS 3 0.118 54 67 31 1.220 2.126 2.638 AREA SENSORS WIRE-SAVING SYSTEMS The spacer for intermediate supporting bracket MS-SF2B-2 can be used as a spacer for eliminating the dead zone when mounting the light curtain laterally. 3 0.118 MICRO PHOTOELECTRIC SENSORS INDUCTIVE PROXIMITY SENSORS The CAD data in the dimensions can be downloaded from our website. 3.6 0.142 Two main unit mounting brackets per set (for rear mounting and side mounting) (Note) Note: The intermediate supporting bracket MS-SF2B-2 is enclosed with the following products. The quantity differs depending on the product as shown below: 1 set: S  F2B-H□ ··· Light curtain with 40 to 56 beam channels SF2B-A□ ··· Light curtain with 20 to 28 beam channels 2 sets: S  F2B-H□ ··· Light curtain with 64 to 80 beam channels SF2B-A□ ··· Light curtain with 32 to 40 beam channels 3 sets: S  F2B-H□ ··· Light curtain with 88 to 96 beam channels SF2B-A□ ··· Light curtain with 44 to 48 beam channels Four bracket set Eight M3 (length 5 mm 0.197 in) hexagon-socket-head bolts are attached. Light Curtain Type 2 DIMENSIONS (Unit: mm in) 634 SF2B SERIES Ver.2 The CAD data in the dimensions can be downloaded from our website. MS-SF2B-5 Adapter mounting bracket for SF2-A / SF2-N (Optional) Rear mounting Side mounting 28 1.102 12 0.472 22.5 0.886 16.5 0.650 9.5 0.374 30° 30° 16.5 0.650 22.5 0.886 9.5 16.5 0.650 0.374 9.5 30° 0.374 6 0.236 4 0.157 5.3 0.209 13.5 0.531 18 0.709 MICRO PHOTOELECTRIC SENSORS 6 0.236 AREA SENSORS 3.5 0.138 LIGHT CURTAINS / SAFETY COMPONENTS 9.5 0.374 28 12 1.102 0.472 30° 13.5 16.5 0.531 0.650 5.3 4 0.209 0.157 3.5 0.138 8.2 0.323 5.5 0.217 5.5 0.217 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS 18 0.709 PARTICULAR USE SENSORS 5.5 0.217 26.6 1.047 43.25 1.703 8 0.315 8 0.315 t2 t 0.079 10.5 0.413 28 1.102 20.5 0.807 LASER MARKERS Rear mounting Side mounting 6 0.236 28 1.102 12 0.472 30° 16.5 0.650 30° 13.5 0.531 18 0.709 8.2 0.323 5.5 0.217 16.5 13.5 0.531 0.650 t2 t 0.079 20.5 0.807 43.25 1.703 Selection Guide 10.5 0.413 28 1.102 20.5 0.807 Optical Touch Switch 40 1.575 28 1.102 20 0.787 4 0.157 4 0.157 5.5 0.217 32 1.260 19.5 0.768 40.5 1.594 40.5 1.594 Material: Stainless steel (SUS304) 8.4 0.331 13.5 0.531 Four brackets (R type × 2 and L type × 2) per set Eight M3 (length 5 mm 0.197 in) hexagon-socket-head bolts are attached. Definition of Sensing Heights SF4C 20.5 0.807 21 15.5 0.827 0.610 32 1.260 19.5 0.768 40.5 1.594 SF2C SF4B t2 t 0.079 SF2B 5.5 0.217 40.5 1.594 8.4 0.331 3 (0.118 ) Control Units SF4B-C 16.5 9.5 0.374 0.650 16.5 0.650 Light Curtains Safety Components 2 0.079 Adapter mounting bracket for NA40 (Optional) 9.5 0.374 3 (0.118 ) 17 0.669 8 0.315 40 1.575 28 1.102 20 0.787 9 0.354 UV CURING SYSTEMS 5.5 0.217 10.7 0.421 Four brackets (R type × 2 and L type × 2) per set M3 (length 5 mm 0.197 in) hexagonsocket-head bolts (eight bolts for light curtain mounting, eight bolts for beam axis alignment) are attached. 21 0.827 MACHINE VISION SYSTEMS 18 0.709 Material: Stainless steel (SUS304) MS-SF2B-6 15.5 0.610 FA COMPONENTS 12 28 30° 0.472 1.102 26.6 1.047 8 0.315 t2 t 0.079 ENERGY CONSUMPTION VISUALIZATION COMPONENTS 5.5 0.217 10.7 0.421 20.5 0.807 HUMAN MACHINE INTERFACES 8.2 0.323 5.5 0.217 17 0.669 26.6 43.25 1.047 1.703 10.5 0.413 28 1.102 9.5 0.374 5.3 0.209 4 0.157 4 0.157 5.3 0.209 PLC 22.5 0.886 16.5 0.650 9.5 0.374 30° 3.5 0.138 22.5 9.5 16.5 0.886 0.374 0.650 6 0.236 3.5 0.138 MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES 2 0.079 20.5 0.807 SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS 10.7 0.421 10.7 0.421 10.5 0.413 28 1.102 SENSOR OPTIONS 17 0.669 17 0.669 26.6 43.25 1.047 1.703 9.5 0.374 LASER SENSORS PHOTOELECTRIC SENSORS 8.2 0.323 5.5 0.217 FIBER SENSORS 9 0.354 13.5 0.531 BSF4-AH80 635 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS Light Curtain Type 2 DIMENSIONS (Unit: mm in) Adapter bracket for SF1-N (Optional) 40 1.575 40 1.575 28 1.102 20 0.787 AREA SENSORS 28 1.102 20 0.787 20 0.787 9.5 0.374 4 0.157 PRESSURE / FLOW SENSORS 21 15.5 0.827 0.610 INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS The CAD data in the dimensions can be downloaded from our website. MS-SF2B-7 MICRO PHOTOELECTRIC SENSORS LIGHT CURTAINS / SAFETY COMPONENTS SF2B SERIES Ver.2 24 0.945 24 0.945 t2 t 0.079 t2 t 0.079 6 0.236 6.5 0.256 32 1.260 31 1.220 9.5 0.374 20 9.5 0.374 0.787 15.5 0.610 6 0.236 6.5 0.256 32 1.260 6.8 0.268 17 0.669 4 0.157 21 0.827 6.8 0.268 17 0.669 31 1.220 17.2 0.677 31 1.220 31 17.2 0.677 1.220 SENSOR OPTIONS 3 (0.118 ) SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS 4 0.157 PLC HUMAN MACHINE INTERFACES FA COMPONENTS 21 0.827 3 (0.118 ) 25 0.984 24 0.945 t2 t 0.079 t2 t 0.079 9 0.354 9 0.354 11 0.433 19 0.748 Light Curtains Safety Components 6.5 0.256 SF2B-CCB□ Eight M3 (length 5 mm 0.197 in) hexagon-socket-head bolts are attached. 15.5 0.610 Bottom cap cable (Optional) Definition of Sensing Heights SF4B-C SF4C SF2C SF4B SF2B BSF4-AH80 21 0.827 3 0.118 ( 49.8 ( 1.961 ) ) 19 0.748 11 0.433 25 0.984 6.5 0.256 32 1.260 SF2B-CB□ 49.8 ( 1.961 ) (45 1.772) ø6 ø0.236 (8.5 0.335) (8.5 0.335) 15.5 0.610 Bottom cap cable (Optional) L ø6 ø0.236 (8.5 0.335) 4 0.157 (50 1.969) (8 0.315) ø14 ( ø0.551 ) M12 connector (8.5 0.335) (14.5 0.571) (14.5 0.571) Optical Touch Switch Control Units 15.5 0.610 Material: Stainless steel (SUS304) L Selection Guide 9.5 0.374 16.5 0.650 Four brackets (one of each type) per set 32 1.260 MACHINE VISION SYSTEMS UV CURING SYSTEMS 15.5 0.610 6.5 0.256 40 1.575 28 1.102 20 0.787 24 0.945 16.5 0.650 9.5 0.374 3 (0.118 ) 40 1.575 28 1.102 20 0.787 STATIC ELECTRICITY PREVENTION DEVICES ENERGY CONSUMPTION VISUALIZATION COMPONENTS 9 0.354 MEASUREMENT SENSORS LASER MARKERS 6.5 0.256 9 0.354 9.5 0.374 L Model No. SF2B-CCB3 Model No. 3,000 118.110 SF2B-CB05 (-A/B) SF2B-CCB7 7,000 275.590 SF2B-CB5 SF2B-CCB10 10,000 393.700 SF2B-CCB15 15,000 590.551 SF2B-CB10 L 500 19.685 5,000 196.850 10,000 393.700 Light Curtain Type 2 DIMENSIONS (Unit: mm in) SFB-CC3  SFB-CC10 ( ) 636 The CAD data in the dimensions can be downloaded from our website. Extension cable (Optional) 42 1.654 SF2B SERIES Ver.2 SFB-CCJ10E  SFB-CCJ10D ( L ø14 ø0.551 42 1.654 ) Extension cable (Optional) ( 10,000 393.700 ) ø14 ø0.551 ø6 ø0.236 Model No. 3,000 118.110 SFB-CC10 10,000 393.700 INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS L SIMPLE WIRE-SAVING UNITS ø6 ø0.236 (8.5 0.335) WIRE-SAVING SYSTEMS MEASUREMENT SENSORS (8.5 0.335) (14.5 0.571) AREA SENSORS PRESSURE / FLOW SENSORS SF2B-CSL01  SF2B-CSL05 Cable for series connection (Optional) 49.8 ( 1.961 ) MICRO PHOTOELECTRIC SENSORS LIGHT CURTAINS / SAFETY COMPONENTS L SFB-CC3 LASER SENSORS PHOTOELECTRIC SENSORS 47 1.850 ø14 ø0.551 ø6 ø0.236 FIBER SENSORS Model No. L SF2B-CSL01 100 3.937 STATIC ELECTRICITY PREVENTION DEVICES SF2B-CSL05 500 19.685 LASER MARKERS SF-C11 Control unit (Optional) SF-C13 Control unit (Optional) PLC HUMAN MACHINE INTERFACES 6.75 0.266 4 0.157 54.1 2.130 40 1.575 4 0.157 Emitter side connector 25 0.984 35 1.378 67.3 2.650 46 1.811 23 0.906 ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS 130 5.118 UV CURING SYSTEMS 91.6 3.606 3×6=18 0.118×0.236=0.709 130 5.118 6 0.236 10 0.394 13.5 0.531 10 0.394 6 0.236 34.5 3×5=15 1.358 0.118×0.197=0.591 35 1.378 67.3 2.650 11.5 0.453 Receiver side connector 13 0.512 48.8 1.921 5 0.197 6.5 0.256 80 3.150 80.8 3.181 13 0.512 Compatible with 35 mm 1.378 in wide DIN rail 22.5 0.886 5 0.197 Selection Guide 80 3.150 (100 3.937) 6.5 0.256 Compatible with 35 mm 1.378 in wide DIN rail SF-LAT-2B Light Curtains Safety Components Laser alignment tool (Optional) ( ) 21 22 0.827 0.866 Large display unit for light curtain (Optional) 38 1.496 66.5 2.618 16.8 0.661 5.3 0.209 28 1.102 48 1.890 Definition of Sensing Heights SF4B-C 25 0.984 35.5 40.1 1.398 23 1.579 0.906 4.6 0.181 Optical Touch Switch Control Units 22.8 0.898 18.3 0.720 ø12 ø0.472 28 1.102 20 0.787 SF-IND-2 SF4C SF2C 18 1.102 28 1.102 5.5 0.217 ø3.6 ø0.142 Cable, 3m 9.843 ft long 25.4 1.000 t 1.6 t 0.063 6.6 0.260 10.4 0.409 92 3.622 Material: Bracket ··· Cold rolled carbon steel (SPCC)(Black chromate) Enclosure ··· POM Cover ··· Polycarbonate SF4B SF2B BSF4-AH80
SF2B-A28SL 价格&库存

很抱歉,暂时无法提供与“SF2B-A28SL”相匹配的价格&库存,您可以联系我们找货

免费人工找货