SF4D
RELAY
Polarized monostable
safety relay with forcibly
guided double contacts
FEATURES
53.3
33
• Relay complies with IEC 61810-3, Type B and with IEC/EN 603351 (GWT)
16.5
• Overvoltage category as per IEC 60664-1 III / 4kV
• Rated voltage
as per IEC 60664-1
basic insulation
length: 3.0
Tolerance 0.3mm
Weight approx. 47g
Polution degree
2
2
3
inside outside inside
400V
400V
250V
forcibly linked
pair only
250V
250V
250V
all other
contacts
400V
400V
400V
Coil-contact
Contact-contact
SPECIFICATIONS
Contact
Characteristics
Contact configuration (a = normally open / NO,
b = normally closed / NC)
Contact material
4a4b
AgSnO2, with Au flash
Contact resistance (initial at 6V DC, 1A)
Making and breaking capacities (breathing
hole open)*1
Max. switching voltage
Min. switching voltage / min. switching current
Pick-up / drop-out / bounce time
(approx. values at Unominal)
Mechanical life
30m
6A 250V / 3A 24V
400V
10V / 10mA
18.5 / 7.5 / 3ms
107ops
Max. switching frequency (without load)
Permissible ambient temperature at nominal
power consumption
Upper temperature limit
10Hz
-40°C to +70°C
105°C
Test voltage:
open contact / contact-contact / contact-coil
2500 / 2500 /
2500Vrms
109
Insulation resistance at 500V DC (initial)
Shock resistance (11ms)
NO/NC*2
30G
Vibration resistance 10 – 200 Hz (10 – 55 Hz,
amplitude 2 mm)*2
Degree of protection
10G
IP67 / IP30*3
Unit weight
Coil
Operate / release voltage (% of Unominal at
20°C)
Pick-up/nominal power consumption at 20°C
47g
Important: Relay characteristics may be influenced by:
75% / 15%
280 / 500mW
• strong external magnetic fields
• magnetic conductive materials near the relay
• narrow top-to-top mounting (printed surface to printed surface)
Remarks:
Note:
*1 According to EN 60947-5-1: 1997, table 4 AC15 / DC13
*2 Contact interruption 0.5
>0.5
¦
>0.5
>0.5
>0.5
>0.5
>0.5
¦
>0.5
>0.5
State of other contacts
3
4
5
6
>0.5
¦
>0.5
¦
>0.5
>0.5
>0.5
>0.5
>0.5
¦
>0.5
>0.5
¦
>0.5
>0.5
>0.5
>0.5
>0.5
¦
>0.5
¦
>0.5
7
>0.5
>0.5
¦
>0.5
>0.5
8
¦
>0.5
>0.5
¦
>0.5
>0.5
>0.5: contact gap is kept at
min. 0.5 mm .020 inch
¦: contact closed
Empty cells:
either closed or open
* Contact gaps are shown at the initial state.
If the contacts change state owing to loading/breaking it is necessary to check
the actual loading.
For Cautions for Use, see Relay Technical Information.
ds_61407_en_sf4d: 160117D
6
很抱歉,暂时无法提供与“SF4D-DC18V”相匹配的价格&库存,您可以联系我们找货