1 SAFETY CAUTIONS
Always observe
●● This section explains important rules that must be observed to prevent human injury and property damage.
■■ The hazards that may occur if the product is used incorrectly are described and
classified by level of harm.
WARNING
CAUTION
2 STANDARDS / REGULATIONS
●● This product complies with the standards / regulations below.
EMC Directive
3 CONTENTS OF PACKAGE
Controller
1 pc.
Quick Instruction Guide (Japanese, English, Chinese)
1 pc. each.
General Information for Safety, Compliance, and Instructions (23 languages) 1 pc.
4 OVERVIEW
●● This device is a communication module that is used to copy function settings in a
light curtain and to initialize the device.
●● This device can be used with a computer to set various functions of a light curtain.
You can also check and change the settings of various functions (muting, blanking, etc.), and monitor the intensity of received light.
5 DESCRIPTION OF PARTS
11
Risk of death or serious injury.
Risk of minor injury or property damage.
●● Use this device as per its specifications. Do not modify this device since its functions and capabilities may not be maintained and it may malfunction.
●● This device has been developed / produced for industrial use only.
●● This product is suitable for indoor use only.
●● Use of this device under the following conditions or environments is not presupposed. Please consult us if there is no other choice but to use this device in such
an environment.
1) Operating this device under conditions or environments not described in this
manual.
2) Using this device in the following fields: nuclear power control, railroad, aircraft,
auto mobiles, combustion facilities, medical systems, aerospace development,
etc.
●● Note that this device may be damaged if it is subject to a strong shock (if it is
dropped onto the floor, for example).
●● In case of disposal, dispose this device as an industrial waste.
1
♦♦ Engineer
• The engineer would be a person who is appropriately educated, has widespread knowledge and experience, and can solve various problems which
may arise during work, such as a machine designer, installer or employer etc.
♦♦ Operator
• The operator should read this instruction manual thoroughly, understand its
contents, and perform operations following the procedures described in this
manual for the correct operation of this device.
• In case this device does not perform properly, the operator should report this
to the employer and stop the machine operation immediately. The machine
must not be operated until correct performance of this device has been confirmed.
♦♦ Environment
• Do not use a mobile phone or a radio phone near this device.
• Do not install this device in the following places:
1) A location exposed to direct sunlight
2) A location where condensation may form due to sudden changes of temperature
3) A location where there are corrosive or combustible gases
4) A location with significant dirt, metal powder, or salt
5) A location where organic solvents such as benzene, paint thinner or alcohol, or strong alkaline substances such as ammonia or caustic soda, may
come in contact with the device or are present in the air.
6) A location with significant steam or dust, a location subject to vibration or
shock, or a location where water droplets may come into contact with the
device.
7) A location near high-voltage lines, high-voltage equipment, power lines,
power equipment, equipment with an amateur radio transmitter, or equipment that generates large switching surges (minimum 100mm)
♦♦ Other matters
• Never modify this device. Risk of impaired device functionality and death or
serious injury.
10
3
9
4
8
5
WARNING
♦♦ Machine designer, installer, employer and operator
• The machine designer, installer, employer and operator are solely responsible
to ensure that all applicable legal requirements relating to the installation and
the use in any application are satisfied and all instructions for installation and
maintenance contained in the instruction manual are followed.
• Whether this device functions as intended to and systems including this device comply with safety regulations depends on the appropriateness of the application, installation, maintenance and operation. The machine designer, installer, employer and operator are solely responsible for these items.
2
6
Name
7
Function
1
Power indicator (Green)
Lights when the device is connected to a light curtain. Blinks when the device is only connected to a PC.
2
Data indicator (Orange)
Lights when data is saved if copy protect is invalid.
Blinks when data is saved if copy protect is valid.
3
READ indicator (Orange)
Lights when the READ key is pressed. Blinks during communication to read
data.
4
READ key
Press to read data.
5
ENTER key
Press to execute a setting or function.
6
Strap holder
Use this holder when using a strap (purchase separately).
7
Mini USB connector
For connection to a PC.
8
WRITE key
Press to write data.
9
WRITE indicator (Orange)
Lights when the WRITE key is pressed. Blinks during communication to write
data.
10
ERROR indicator (Yellow)
Lights when an error occurs.
11
Connection cable (1.5m)
For connection to a light curtain.
6 CONNECTION
●● The device can be connected to the light curtain even when the light curtain power is ON. To prevent short-circuiting caused by tools or refuse, it is recommended
that the work be performed with the power OFF.
Connecting to a light curtain
1. Make sure that the light curtain power is OFF, and remove the indicator cover.
Light curtain
Indicator cover
2. Connect the device's connection cable to the connector inside the light curtain.
Connection cable
Connector
CAUTION
The device cannot be used in a continuous connection with the light curtain.
3. Turn ON the light curtain power.
4. The device starts up.
Disconnecting from the light curtain
Connecting to a light curtain and a PC
1. Turn OFF the light curtain power.
2. Remove the device's connection cable from the connector inside the light curtain.
1. Make sure that the light curtain power is OFF, and remove the indicator cover.
Light curtain
Indicator cover
2. Connect the device's connection cable to the connector inside the light curtain.
3. All indicators on the device turn OFF.
4. Attach the indicator cover on the light curtain.
Tighten to a torque of 0.3N·m or less.
Connection cable
Connector
3. Connect the device to a PC with a USB 2.0 cable (A: miniB) (purchase separately).
CAUTION
There is packing on the indicator cover. If the packing is not fitted on the cover
properly, fit as shown below before attaching to the device.
USB 2.0 cable (A: miniB)
(purchase separately)
The device
4. The device starts up.
5. Turn ON the light curtain power.
Disconnecting from the light curtain and the PC
Connecting to a PC
1. Connect the device to a PC with a USB 2.0 cable (A: miniB) (purchase separately).
1. Turn OFF the light curtain power.
2. Remove the device's connection cable from the connector inside the light curtain.
USB 2.0 cable (A: miniB)
(Purchase separately)
The device
2. The device starts up.
3. Disconnect the USB cable at the device or at the PC.
Disconnecting from a PC
1. Disconnect the USB cable at the device or at the PC.
2. All indicators on the device turn OFF.
4. All indicators on the device turn OFF.
5. Attach the indicator cover on the light curtain.
Tighten to a torque of 0.3N·m or less.
CAUTION
There is packing on the indicator cover. If the packing is not fitted on the cover
properly, fit as shown below before attaching to the device.
7 FUNCTIONS
Copy function / Write function (WRITE)
●● The device is equipped with the functions described below.
Procedure
State
Copy function
●● This function “reads” the settings in one light curtain and “writes” the settings to
another light curtain.
1
Connect the device's connection cable to the connector inside the light curtain.
All indicators light for about 1 second.
2
Indicators other than the power indicator (green) and
data indicator (orange) turn OFF.
3
Press the WRITE key for at least 2 seconds.
4
The WRITE indicator (orange) lights up.
5
Press the ENTER key within 5 seconds.
To cancel “WRITE”, press any key other than the ENTER key.
• This function reads the settings and log information in a light curtain and saves
the information in the device’s memory.
• This function writes settings saved in the device to a light curtain.
Description
Saved data initialization function
●● This function initializes the settings and log information saved in the device.
I/F communication function
●● This function converts the RS-485 communication of the light curtain to the USB
communication of the PC (and vice-versa).
8 OPERATION
Copy function / read function (READ)
Procedure
State
Description
1
Connect the device's connection cable to the connector inside the light curtain.
All indicators light for about one second.
2
Indicators other than the power indicator (green) turn
OFF.
[If data is saved in the device, the data indicator (orange) also remains ON.]
6
The WRITE indicator (orange) blinks and writing starts.
The control output (OSSD1 / 2) of the light curtain
turns OFF.
3
Press the READ key for at least 2 seconds.
7
The WRITE indicator (orange) turns OFF.
The settings saved in the device are written to the light
curtain.
4
The READ indicator (orange) lights up.
8
Remove the device's connection cable from the connector inside the light curtain.
Note: Data written with the copy function may be lost due to external causes. After copying settings, check the operation of the light curtain before use.
5
Press the ENTER key within 5 seconds.
To cancel “READ”, press any key other than the ENTER key.
Saved data initialization function
Procedure
State
Description
6
The READ indicator (orange) blinks and reading starts.
The control output (OSSD1 / 2) of the light curtain
turns OFF.
1
Connect the device's connection cable to the connector inside the light curtain.
All indicators light for about 1 second.
7
The READ indicator (orange) turns OFF and the data
indicator (orange) lights up.
The settings and log information of the connected light
curtain are copied to the device.
2
Indicators other than the power indicator (green) and
data indicator (orange) turn OFF.
8
Remove the device's connection cable from the connector inside the light curtain.
3
Press the READ key and WRITE key at the same time
for at least 2 seconds.
4
The READ indicator (orange) and WRITE indicator
(orange) light up.
5
Press the ENTER key within 5 seconds.
To cancel “INITIALIZE”, press any key other than the
ENTER key.
6
The data indicator (orange) turns OFF.
The settings and logs saved in the device are erased
and initialized.
7
Remove the device's connection cable from the connector inside the light curtain.
9 TROUBLESHOOTING
Problem
Cause
Solution
All indicators are turns OFF
Connector not connected securely.
Connect the connector firmly.
The ERROR indicator (yellow) blinks and data cannot
be read.
Sensor communication error.
(Noise or communication circuit failure)
Check the ambient noise conditions near the device.
Data is not saved.
The data was not saved, so read the data from the
source and write to the device again.
You used the write function in
a different light curtain configuration.
Make sure the data configuration matches the configuration of the connected light curtain.
Copy protection is in effect.
If the data indicator (orange) is blinking, writing is
prohibited (copy protection).
Use the Configurator Light Curtain software to cancel copy protection.
Sensor communication error.
(Noise or communication circuit failure)
Check the ambient noise conditions near the device.
The saved data is corrupted.
The saved data is corrupted, so initialize the device.
Read the data from the source and write to the device again.
Internal failure.
If the ERROR indicator (yellow) does not turn OFF
after you initialize the device, replace the device.
Internal failure.
Replace the device.
Turn the power ON again.
Turn ON the light curtain power again.
Power supply break, wire
break, etc.
Repeat the write.
During optical synchronization, only the emitter or only
the receiver wrote data.
If the light curtain is configured by optical synchronization, perform read/write to both the emitter and receiver.
The ERROR indicator (yellow) and data cannot be written.
The ERROR indicator (yellow) is lit.
The data indicator (orange)
does not turn OFF and data
cannot be initialized.
I wrote settings to the light
curtain but the settings are
not applied.
10 SPECIFICATIONS
Communication module for SF4D Series
Product name
SF4D-TM1
Model No.
Light curtain: RS-485 bidirectional communication (dedicated protocol)
PC (computer): USB
Communication method
Protective structure
IP40 (IEC)
Ambient temperature
-10 to +55°C (No condensation or icing), Storage: -25 to +60°C
Ambient humidity
30 to 85% RH, Storage: 30 to 95% RH
Elevation
2,000m or less (Note)
Connection method
USB: Mini B male, cable with connector (1.5m)
Weight (main unit only)
Approx. 75g
Note: Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric
pressure at 0m.
11 DIMENSIONS (Units: mm)
7
37.2
20.4
ø3.7 cable
96.3
(0.6)
46
15.4
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
PRINTED IN JAPAN
© Panasonic Industrial Devices SUNX Co., Ltd. 2016